HomeMy WebLinkAboutT-434302CO i C) i 0 Lu ABBREVIATIONS: 1 P 1 POLE (2P, 3P, 4P, ETC.) A AMPERE AC ABOVE COUNTER ACLG ABOVE CEILING ADO AUTOMATIC DOOR OPENER AF AMPFRAME AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFI ARC FAULT CIRCUIT INTERRUPTER AHU AIR HANDLING UNIT AL ALUMINUM ALT ALTERNATE AMP AMPERE AMPL AMPLIFIER ANNUN ANNUNCIATOR APPROX APPROXIMATELY AQ-STAT AQUASTAT ARCH ARCHITECT, ARCHITECTURAL AS AMP SWITCH AT AMP TRIP ATS AUTOMATIC TRANSFER SWITCH AUTO AUTOMATIC AUX AUXILIARY AV AUDIO VISUAL AWG AMERICAN WIRE GAUGE BATT BATTERY BD BOARD BLDG BUILDING BMS BUILDING MANAGEMENT SYSTEM C CONDUIT CAB CABINET CAT CATALOG CATV CABLE TELEVISION CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CCT CIRCUIT CLG CEILING COMB COMBINATION CMPR COMPRESSOR CONN CONNECTION CONST CONSTRUCTION CONT CONTINUATION OR CONTINUOUS CONTR CONTRACTOR CONV CONVECTOR CP CIRCULATING PUMP CRT CATHODE-RAY TUBE CT CURRENT TRANSFORMER CTR CENTER CU COPPER DCP DOMESTIC WATER CIRCULATING PUMP DEPT DEPARTMENT DET DETAIL DIA DIAMETER DISC DISCONNECT DIST DISTRIBUTION DN DOWN DPR DAMPER DS SAFETY DISCONNECT SWITCH DT DOUBLE THROW DWG DRAWING EC ELECTRICAL CONTRACTOR ELEC ELECTRIC, ELECTRICAL ELEV ELEVATOR ELU EMERGENCY LIGHTING UNIT EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM EMT ELECTRICAL METALLIC TUBING EP ELECTRIC PNEUMATIC EQUIP EQUIPMENT EWC ELECTRIC WATER COOLER EXIST EXISTING EXH EXHAUST EXP EXPLOSION PROOF IC INTERRUPTING CAPACITY IG ISOLATED GROUND IMC INTERMEDIATE METAL CONDUIT INCAND INCANDESCENT IR INFRARED I/W INTERLOCK WITH J-BOX JUNCTION BOX KV KILOVOLT KVA KILOVOLT -AMPERE KVAR KILOVOLT -AMPERE REACTIVE KW KILOWATT KWH KILOWATT HOUR LOC LOCATE OR LOCATION LT LIGHT LTG LIGHTING LTNG LIGHTNING LV LOW VOLTAGE MAX MAG.S M/C MC MCB MCC MDC MDP MFR MFS MH MIC MIN MISC MLO MMS MOA MSP MSBD MT MT.0 MTS MTR N.C. NEC NEMA NFDS NIC NL N.O. NPF NTS OH OL PA PB PE PED PF PH PIV PNL PP PR PRI PROJ PRV PT PVC PWR QUAN MAXIMUM MAGNETIC STARTER MOMENTARY CONTACT MECHANICAL CONTRACTOR MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION CENTER MAIN DISTRIBUTION PANEL MANUFACTURER MAIN FUSED DISCONNECT SW MANHOLE MICROPHONE MINIMUM MISCELLANEOUS MAIN LUGS ONLY MANUAL MOTOR STARTER MULTIOUTLET ASSEMBLY MOTOR STARTER PANELBOARD MAIN SWITCHBOARD MOUNT EMPTY CONDUIT MANUAL TRANSFER SWITCH MOTOR, MOTORIZED NORMALLY CLOSED NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION NON -FUSED SAFETY DISCONNECT SWITCH NOT IN CONTRACT NIGHT LIGHT NORMALLY OPEN NORMAL POWER FACTOR NOT TO SCALE OVERHEAD OVERLOADS PUBLIC ADDRESS PULL BOX OR PUSHBUTTON PNEUMATIC ELECTRIC PEDESTAL POWER FACTOR PHASE POST INDICATING VALVE PANEL POWER POLE PAIR PRIMARY PROJECTION POWER ROOF VENTILATOR POTENTIAL TRANSFORMER POLYVINYL CHLORIDE (CONDUIT) POWER QUANTITY RCPT RECEPTACLE FA FIRE ALARM REQD REQUIRED FABP FIRE ALARM BOOSTER POWER RM ROOM FACP FIRE ALARM CONTROL PANEL RSC RIGID STEEL CONDUIT FCU FAN COIL UNIT RTU ROOF TOP UNIT FIXT FIXTURE FLR FLOOR SC SURFACE CONDUIT FLUOR FLUORESCENT SEC SECONDARY FU FUSE SHT SHEET FUDS FUSED SAFETY DISCONNECT SWITCH SIM SIMILAR S/N SOLID NEUTRAL GA GAUGE SPEC SPECIFICATION GAL GALLON SPKR SPEAKER GALV GALVANIZED SP SPARE GC GENERAL CONTRACTOR SR SURFACE RACEWAY GEN GENERATOR SS STAINLESS STEEL G,GFI GROUND FAULT CIRCUIT INTERRUPTER SSW SELECTOR SWITCH GFP GROUND FAULT PROTECTOR S/S STOP/START PUSHBUTTONS GND GROUND STA STATION GRS GALVANIZED RIGID STEEL (CONDUIT) STD STANDARD GYP BD GYPSUM BOARD SURF SURFACE MOUNTED SW SWITCH HOA HANDS -OFF -AUTOMATIC SWITCH SWBD SWITCHBOARD HORIZ HORIZONTAL SYM SYMMETRICAL HP HORSEPOWER SYS SYSTEM HPF HIGH POWER FACTOR HT HEIGHT TEL TELEPHONE HTG HEATING TEL/DATA TELEPHONE/DATA HTR HEATER TERM TERMINAL HV HIGH VOLTAGE TL TWIST LOCK HVAC HEATING, VENTILATING AND AIR TR TAMPER RESISTANT CONDITIONING T-STAT THERMOSTAT TTC TELEPHONE TERMINAL CABINET TV TELEVISION TVTC TELEVISION TERMINAL CABINET TYP TYPICAL UC UNDER COUNTER UE UNDERGROUND ELECTRICAL UG UNDERGROUND UH UNIT HEATER UNO UNLESS NOTED OTHERWISE UT UNDERGROUND TELEPHONE UTIL UTILITY UV ULTRAVIOLET V VOLT VA VOLT-AMPERES VDT VIDEO DISPLAY TERMINAL VERT VERTICAL VFD VARIABLE FREQUENCY DRIVE VOL VOLUME W WATT W/ WITH WG WIRE GUARD WH WATER HEATER W/O WITHOUT WP WEATHERPROOF XFMR TRANSFORMER XFR TRANSFER z ANGLE @ AT ♦ DELTA FEET INCHES # NUMBER 0 PHASE C CENTER LINE P PLATE BID SET BP 4/10/25 PERMIT COMMENTS BP 4/14/25 ADDENDUM 1 BP 4/17/25 ADDENDUM 2 BP 5/1/25 PERMIT COMMENTS BP 5/21/25 ■ ■ . ELECTRICAL GENERAL NOTES: GENERAL: 1. COORDINATE ELECTRICAL WORK WITH MECHANICAL, ARCHITECTURAL, STRUCTURAL, CIVIL AND LANDSCAPE WORK SHOWN ON OTHER CONTRACT DOCUMENTS. PROVIDE ADDITIONAL OFFSETS FOR COORDINATED INSTALLATION WHERE REQUIRED. 2. FIELD COORDINATE FINAL MECHANICAL AND EQUIPMENT LOCATIONS ALONG WITH CONNECTION REQUIREMENTS AND CONTROL WIRING PRIOR TO ROUGH -IN. 3. CONTRACTOR IS RESPONSIBLE FOR PROVIDE ALL LINE VOLTAGE CIRCUITING AND CONNECTIONS TO MECHANICAL EQUIPMENT, PACKAGED UNITS, CONTROL PANELS, MOTOR STARTERS, MOTOR CONTROLLERS, VARIABLE FREQUENCY DRIVES AND SIMILAR EQUIPMENT. COORDINATE ADDITIONAL REQUIREMENTS WITH CONTROLS CONTRACTOR. 4. COORDINATE EQUIPMENT CONNECTIONS WITH MANUFACTURERS' CERTIFIED DRAWINGS. 5. COORDINATE ELECTRICAL, COMMUNICATIONS, AND ELECTRONIC SAFETY AND SECURITY WORK PRIOR TO INSTALLATION. EQUIPMENT ACCESS TAKES PRECEDENCE OVER CONDUIT FOR AVAILABLE SPACE. 6. WHERE USED, THE TERM "PROVIDE" SHALL MEAN "FURNISH AND INSTALL". 7. PROVIDE CONDUCTORS OPERATING AT 50 VOLTS OR GREATER IN RACEWAY. PROVIDE METAL RACEWAY WITHIN THE STRUCTURE ABOVE THE FLOOR SLAB. PROVIDE PVC RACEWAY BELOW THE FLOOR SLAB AND UNDERGROUND RACEWAY OUTSIDE THE STRUCTURE. 8. CONDUIT AND WIRE IS NOT PERMITTED TO BE INSTALLED BELOW FLOOR SLAB UNLESS INDICATED ON PLAN BY DASHED CONDUIT. 9. LEAVE THE SITE CLEAN AND READY FOR OCCUPANCY. REMOVE DIRT, DEBRIS, EMPTY CARTONS, TOOLS, CONDUIT AND WIRE SCRAPS AND MISCELLANEOUS SPARE EQUIPMENT AND MATERIALS USED IN THIS DIVISION OF THE WORK DURING CONSTRUCTION. COMPONENTS SHALL BE FREE OF DUST, GRIT AND FOREIGN MATERIALS AND LEFT AS NEW BEFORE FINAL ACCEPTANCE OF WORK. 10. PERFORM WORK TO COMPLY WITH THE STANDARD PRACTICES FOR GOOD WORKMANSHIP PUBLISHED BY NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION (NECA). COMPLY WITH THE LATEST ENFORCED EDITION OF THE NATIONAL ELECTRICAL CODE (NEC), LOCAL CODES, AMENDMENTS, AND ORDINANCES. 11. PERFORM ELECTRICAL WORK UNDER THE SUPERVISION OF A LICENSED MASTER ELECTRICIAN. PROCURE PERMITS AND LICENSES AND PAY FEES ASSOCIATED WITH THIS WORK. 12. CONTRACTOR IS RESPONSIBLE FOR SUBMITTING ALL DOCUMENTATION REQUIRED TO CITY OF RENTON FOR PERMITTING. COORDINATE WITH ENGINEER FOR ANY ADDITIONAL DOCUMENTATION. 13. PROVIDE NEW, COMMERCIAL GRADE MATERIALS FURNISHED FOR THIS PROJECT THAT ARE FREE OF DEFECTS, AND LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY UNO. 14. CONTRACTOR IS RESPONSIBLE FOR WIRING ELECTRICAL ITEMS SHOWN ON DRAWINGS. 15. PROVIDE 4" MINIMUM CONCRETE BASES (HOUSEKEEPING PADS) UNDER FLOOR MOUNTED ELECTRICAL EQUIPMENT. THIS INCLUDES, BUT IS NOT LIMITED TO SWITCHBOARDS, GENERATORS, TRANSFORMERS, AND MOTOR CONTROL CENTERS. COMPLY WITH REQUIREMENTS FOR EQUIPMENT BASES AND FOUNDATIONS SPECIFIED IN DIVISION 03. 16. COORDINATE ATTACHMENTS TO STRUCTURE TO VERIFY THAT ATTACHMENT POINTS ON EQUIPMENT AND STRUCTURE CAN ACCEPT SEISMIC, WEIGHT, AND OTHER LOADS IMPOSED. 17. MAINTAIN INDICATED FIRE AND SMOKE RATING OF WALLS, PARTITIONS, CEILINGS, AND FLOORS AT ELECTRICAL PENETRATIONS. SEAL PENETRATIONS WITH FIRESTOP MATERIAL. PROVIDE MATERIAL IN ACCORDANCE WITH ASTM E 814 AND UL 1479 3M OR APPROVED. COMPLY WITH REQUIREMENTS SPECIFIED IN DIVISION 07. 18. PROVIDE FIREBLOCKING AND DRAFT STOPPING AT ELECTRICAL PENETRATIONS IN COMBUSTIBLE CONCEALED SPACES PER THE INTERNATIONAL BUILDING CODE. 19. REFER TO TYPICAL DETAILS PROVIDED IN THIS DRAWING SET FOR EQUIPMENT INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR CONFORMANCE WITH DETAILS. 20. LOCATIONS AND SIZES OF FLOOR, WALL, AND ROOF OPENINGS SHALL BE COORDINATED WITH OTHER TRADES INVOLVED. INCLUDE IN THE COST OF ELECTRICAL WORK, CUTTING, CORING, PATCHING AND PAINTING OF EXISTING WALLS, CEILINGS, FLOORS AND ROOFS AS REQUIRED TO ACCOMMODATE WORK AS INDICATED IN THE ELECTRICAL CONTRACT DOCUMENTS, UNLESS SPECIFICALLY SHOWN ON ARCHITECTURAL DRAWINGS. SURVEYED: DESIGNED: N S DRAWN: NS CHECKED: BP APPROVED: BP SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 21. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF THEIR OWN PROPERTY ON THE JOB SITE. OWNER ASSUMES NO RESPONSIBILITY FOR PROTECTION OF PROPERTIES AGAINST FIRE, THEFT AND ENVIRONMENTAL CONDITIONS. 22. CLEAN THE JOB SITE DAILY AND REMOVE FROM THE PREMISES ANY DIRT AND DEBRIS CAUSE BY THE PERFORMANCE OF THE WORK INCLUDED IN THIS CONTRACT. BEFORE SUBSTANTIAL COMPLETION, CLEAN EQUIPMENT, FIXTURES, EXPOSED CONDUIT AND SIMILAR ITEMS. 23. PROVIDE EQUIPMENT THAT FITS INTO THE SPACE ALLOTTED AND ALLOWS ADEQUATE ACCEPTABLE CLEARANCE FOR INSTALLATION, REPLACEMENT, ENTRY, SERVICING AND MAINTENANCE. COORDINATE WITH OTHER TRADES TO ENSURE NO CONFLICT WITH REQUIRED CLEARANCES. 24. BUILDING SPACE IS LIMITED. STRONG ATTENTION TO DETAIL AND CARE MUST BE TAKEN WHEN DEVELOPING SHOP DRAWING SO ROUTING IS COORDINATED WITH OTHER DISCIPLINES. 25. MATERIALS WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. EXISTING ELECTRICAL: 1. WORK SHALL BE PERFORMED IN A CLEAN AND WORKMANLIKE MANNER. CARE SHALL BE EXERCISED TO MINIMIZE ANY INCONVENIENCE OR DISTURBANCE TO OTHER AREAS OF THE BUILDING WHICH ARE TO REMAIN IN OPERATION. ISOLATE WORK AREAS BY MEANS OF TEMPORARY PARTITIONS AND/OR TARPS TO KEEP DUST AND DIRT WITHIN THE CONSTRUCTION AREA. 2. EXISTING MATERIALS THAT ARE REMOVED SHALL NOT BE REUSED IN NEW SYSTEMS, EXCEPT WHERE INDICATED AS BEING RELOCATED. 3. WHERE INDICATED, CONDUIT OR PORTIONS OF CONDUIT SHALL BE REUSED. REFER TO DRAWING PLANS FOR POINTS OF CONNECTIONS. 4. PROVIDE TEMPORARY SUPPORT OF EXISTING ELECTRICAL SYSTEMS WHERE REQUIRED BY DEMOLITION OR ALTERATION OF EXISTING STRUCTURE DURING CONSTRUCTION. COORDINATE WITH GENERAL CONTRACTOR AND PROVIDE ALL NECESSARY CONDUIT AND EQUIPMENT SUPPORTS AND HANGERS TO MAINTAIN INTEGRITY, SAFETY AND PROPER OPERATION OF EXISTING ELECTRICAL SYSTEMS FOR THE DURATION OF THE WORK. DEMOLITION: 1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE DEMOLITION/INSTALLATION OF ELECTRICAL SYSTEMS AND THOSE REQUIRING ELECTRICAL CONNECTIONS TO MAINTAIN NEC REQUIRED CLEARANCES, INCLUDED BY NOT LIMITED TO AREAS ABOVE ACCESSIBLE CEILINGS. 2. COORDINATE WITH OTHER TRADES FOR PROPER DEMOLITION OF EQUIPMENT. CONSULT THE DRAWINGS OF OTHER TRADES OR CRAFTS TO AVOID CONFLICTS WITH EQUIPMENT, ETC. RESOLVE CONFLICTS PRIOR TO ROUGH -IN AND AT NO ADDITIONAL COST TO THE OWNER. 3. TAKE CAUTION IN DEMOLITION OF ELECTRICAL EQUIPMENT. 4. CONTRACTOR SHALL REMOVE AND LEGALLY DISPOSE OF ALL CONDUIT AND EQUIPMENT INDICATED ON DRAWINGS INCLUDING ALL ASSOCIATED HANGERS, WIREMOLD, WIRING, DEVICES, CONTROLS, AND APPURTENANCES ASSOCIATED WITH EACH PIECE OF EQUIPMENT. 5. EXISTING CONTROL PATHWAYS MAY BE RE -USED. COORDINATE CONTROLS DEMO WORK PRIOR TO DEMOLITION. 6. WHERE EXISTING ITEMS PENETRATE A WALL OR ROOF, CONTRACTOR SHALL PROVIDE INFILL AT (E) PENETRATIONS THROUGH WALL/ROOF WITH LIKE MATERIALS. PATCH & REPAIR TO MATCH SURROUNDING SURFACES INCLUDING PAINT. 7. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT OF EXISTING ELECTRICAL EQUIPMENT WHERE REQUIRED BY DEMOLITION OR ALTERATION OF EXISTING STRUCTURE DURING CONSTRUCTION. COORDINATE WITH GC AND PROVIDE NECESSARY SUPPORTS AND HANGERS TO MAINTAIN INTEGRITY, SAFETY AND PROPER OPERATION OF EXISTING ELECTRICAL SYSTEMS. 8. THE OWNER HAS THE RIGHT TO RETAIN OWNERSHIP OF ANY MATERIALS BEING REMOVED. DELIVER ITEMS TO THE OWNER'S REPRESENTATIVE AS INDICATED IN THE CONTRACT DOCUMENTS. NOTIFY OWNER IN WRITING AT LEAST 7 DAYS IN ADVANCE OF DEMOLITION. CITY OF ,1N C. wasgr RENTON oraAi, Planning/Building/Public Works Dept. �� I�1 �,� IN COMPLIANCE WITH CITY OF RENTON STANDARDS EDEVELOPMENT ENGINEERING HBray 06/13/2025 %jl RSD TRANSPORTATION EXPANSION ELECTRICAL ABBREVIATIONS AND NOTES DATE: 05/21/25 FIELDBOOK: PAGE: DRAWING NO: EOO2 SHEET: OF: 25 OF 30 0 T T C) C) m N , u 0) C) C) C) C) i Nt N Ir 'i1 co C) C) C) i N Q J T-434302