HomeMy WebLinkAboutT-434307SIZE POLE HT. A B 8'-12' 36" 12" 13'-20' 42" 16'. 21'-30' 72" 24" 31'-40' 78" 30" ROi CAI VEI OW irel 01 FILI ANI Wll WE SACK EXPOSED PORTION OF POLE BASE WITH MATCHING GROUT TO FILL VOIDS AND COVER FORM MARKS COPPER EQUIPMENT GROUND CONDL ATTACH TO INTERNAL LUG WELDED Il� OF POLE GROUNDED CONDUCTOR SH SAME SIZE AND TYPE AS SUPPLY CON 2" SECURITY Cf (B) DIAMETER OF POLE BASE SIZED AT THE DIAMETER OF POLE BASE CANOPY PLUS 2" ABOVE BEVEL. TYPICAL POLE BASE DETAIL SCALE:NONE TYPICAL LIGHT AND POLES AS SPECIFIED PROVIDE FLEXIBLE RACEWAY FROM MOUNTING BRACKET TO RIGID CONDUIT STUB UP ADJACENT HAND HOLE. POLE GROUND LUG. TERMINATE EQUIPMENT GROUNDING CONDUCTOR AND FIXTURE GROUND. TERMINATE CONDUITS AT BASE OF HAND HOLE ANCHOR BOLTS, NUTS, AND LEVELING NUTS BY POLE MANUFACTURER. COORDINATE SIZE AND SPACING WITH SUPPLIER. BEVEL 2" AT 45 DEGREES GRADE GROUNDING ELECTRODE CONDUCTOR IN 1/2"C, IRREVERSIBLE CONNECTION AT POLE GROUND LUG, EXOTHERMIC WELD AT GROUND ROD. SEAL BELOW GRADE. INSTALL 1/2" X 10'-0" COPPER GROUND ROD REINFORCING RODS 4#4 VERTICAL WITH 2" MINIMUM COVER & #4 TIES AT 16" O.C. THROUGH DEPTH OF BASE. INSTALL ANCHOR BOLTS AS RECOMMENDED BY POLE MANUFACTURER CONDUIT(S)-REFER TO PLANS. FOR DIRECT BURIED CABLE APPLICATIONS PROVIDE 90' DOWN SWEEP WITH BUSHED ENDS AND SEALED. CONCRETE POLE BASE FINISHED GRADE BURIED IDENTIFICATION TAPE UNDISTURBED EARTH BACKFILL - PLACE AND COMPACT IN 8" LAYERS SAND NOTES: 1. CONDUIT SHALL HAVE A MINIMUM OF 36" OF COVER. 2. PROVIDE A MINIMUM OF 12" HORIZONTAL SEPARATION BETWEEN CONDUIT AND OTHER UTILITIES. 3. CONDUIT SHALL BE 4" SCHEDULE 40, UON. 4. COORDINATE WITH UTILITY COMPANIES FOR ALL REQUIREMENTS. 5. CONFORM TO ALL REQUIREMENTS INDICATED IN CIVIL DRAWINGS AND SPECIFICATIONS. 6. REFER TO SHEET E102 AND COMMUNICATION FLOOR PLANS FOR QUANTITY OF CONDUITS. 7. COORDINATE ROUTING WITH PLUMBING AND STRUCTURAL ELEMENTS. ROUTE CONDUITS BELOW FOOTINGS OR PROVIDE SLEEVES IN FOOTINGS PER STRUCTURAL DETAILS. TYPICAL DUCT BANK DETAIL SCALE:NONE "�E NOTES AND LANDSCAPING NAL REQUIREMENTS. E NOTES NOTES 1,2 E NOTES NOTES- 1 . COORDINATE WITH LANDSCAPE ARCHITECT/DRAWINGS FOR ADDITIONAL DETAILS. 2. GATE HARDWARE AND ACCESS CONTROLS SHALL UTILIZE THE FOLLOWING DISTRICT STANDARD PRODUCTS: 2.1. COMPATIBLE ELECTRIC STRIKE 9600-630 H.E.S. 2.2. SEE SPECIFICATIONS FOR CARD READER AND ADDITIONAL ACCESS CONTROL REQUIREMENTS. 3. HARDWARE SHALL BE MOUNTED AT ADA HEIGHT 42" AFG UNLESS NOTED OTHERWISE. 4. PROVIDE NEMA 3R LOCKABLE WEATHERPROOF ENCLOSURE SIMILAR TO EXISTING PHOTO FOR CABLE ROUTING. 5. PROVIDE BACK BOX AND CARD READER MOUNTED ON BACK SIDE OF WEATHERPROOF CABLE ENCLOSURE. 6. PROVIDE ALL CONDUIT STRAPS/SUPPORTS REQUIRED TO SECURELY MOUNT CARD READER/CABLE ENCLOSURE TO GATE. 7. PROVIDE ADDITIONAL HARDWARE AND ACCESS CONTROL COMPONENTS AS NEEDED TO ACCOMMODATE DISTRICT STANDARDS AND ACCESS CONTROLS SHOWN ON LANDSCAPE DRAWINGS AND INSTALL A COMPLETE AND FULLY FUNCTIONAL SYSTEM COMPATIBLE WITH CARD READER AND SPECIFIED LOCK CORES. SUBMIT ALL COMPONENTS FOR APPROVAL. 8. ALL HARDWARE AND ACCESS CONTROL COMPONENTS SHALL BE RATED FOR EXTERIOR USE. 9. SEE SPECIFICATIONS FOR ACCESS CONTROL REQUIREMENTS. BID SET BP 4/10/25 PERMIT COMMENTS BP 4/14/25 ADDENDUM 1 BP 4/17/25 ADDENDUM 2 BP 5/1/25 PERMIT COMMENTS BP 5/21/25 REVISION GATE WITH PANIC HARDWARE DETAIL SCALE:1/2" = 1'-0" SURVEYED: DESIGNED: NS DRAWN: NS CHECKED: BP APPROVED: BP SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY L4C.0,;_Y0 +0O ri •• Planning/Building/Public Works Dept. NOTES: 1. ROUTE NEW ACCESS CONTROL CONDUIT FROM CABLE JUNCTION BOX TO NEW GATE HARDWARE. SEE SHEET E3.01 FOR PATHWAY ROUTING. ROUTE CABLING THROUGH NEW AND EXISTING PATHWAYS TO ACCESS CONTROL HEAD END IN MDF ROOM AND INTEGRATE NEW CONTROLS AND PROVIDE RE -PROGRAMMING OF EXISTING ACCESS CONTROL SYSTEM FOR A COMPLETE AND OPERABLE SYSTEM. PROVIDE CONDUIT ROUTING PLAN TO OWNER, ENGINEER, CIVIL, AND LANDSCAPE FOR APPROVAL PRIOR TO INSTALLATION. 2. PROVIDE ALL CONDUIT STRAPS/SUPPORTS REQUIRED TO SECURELY MOUNT CARD READER/CABLE ENCLOSURE TO GATE. 3. SEE SPECIFICATIONS FOR ACCESS CONTROL REQUIREMENTS. EXISTING GATE HARDWARE SCALE:NONE IN COMPLIANCE WITH CITY OF RENTON STANDARDS EDEVELOPMENT ENGINEERING HBray 06/13/2025 RSD TRANSPORTATION EXPANSION ELECTRICAL DETAILS DATE: 05/21/25 FIELDBOOK: PAGE: DRAWING NO: E901 SHEET: OF: 30 OF 30 O T T 'C) u J N C) C) C) C) N rr 'i1 M O 0 N Q J T-434307