Loading...
HomeMy WebLinkAboutT-434307SIZE CHART POLE HT. A B 25' 72" 24" SACK EXPOSED PORTION OF POLE BASE WITH MATCHING GROUT TO FILL VOIDS AND COVER FORM MARKS COPPER EQUIPMENT GROUND CONDI ATTACH TO INTERNAL LUG WELDED II` OF POLE GROUNDED CONDUCTOR SH SAME SIZE AND TYPE AS SUPPLY CON 2" SECURITY CE (B) DIAMETER OF POLE BASE SIZED AT THE DIAMETER OF POLE BASE CANOPY PLUS 2" ABOVE BEVEL. TYPICAL POLE BASE DETAIL SCALE: NONE TYPICAL LIGHT AND POLES AS SPECIFIED POLE GROUND LUG. TERMINATE EQUIPMENT GROUNDING CONDUCTOR AND FIXTURE GROUND. TERMINATE CONDUITS AT BASE OF HAND HOLE ANCHOR BOLTS, NUTS, AND LEVELING NUTS BY POLE MANUFACTURER. COORDINATE SIZE AND SPACING WITH SUPPLIER. BEVEL 2" AT 45 DEGREES (2) #4 TIES AT 2" O.C. AT TOP GRADE GROUNDING ELECTRODE CONDUCTOR IN 1/2"C, IRREVERSIBLE CONNECTION AT POLE GROUND LUG, EXOTHERMIC WELD AT GROUND ROD. SEAL BELOW GRADE. INSTALL 1/2" X 10'-0" COPPER GROUND ROD REINFORCING RODS 4#4 VERTICAL WITH 2" MINIMUM COVER & #4 TIES AT 16" O.C. THROUGH DEPTH OF BASE. INSTALL ANCHOR BOLTS AS RECOMMENDED BY POLE MANUFACTURER CONDUIT(S)-REFER TO PLANS. FOR DIRECT BURIED CABLE APPLICATIONS PROVIDE 90' DOWN SWEEP WITH BUSHED ENDS AND SEALED. CONCRETE POLE BASE RECORD DRAWINGS w w NO. REVISION FINISHED GRADE BURIED IDENTIFICATION TAPE UNDISTURBED EARTH BACKFILL - PLACE AND COMPACT IN 8" LAYERS SAND N]nTF.q- 1. CONDUIT SHALL HAVE A MINIMUM OF 36" OF COVER. 2. PROVIDE A MINIMUM OF 12" HORIZONTAL SEPARATION BETWEEN CONDUIT AND OTHER UTILITIES. 3. CONDUIT SHALL BE 4" SCHEDULE 40, LION. 4. COORDINATE WITH UTILITY COMPANIES FOR ALL REQUIREMENTS. 5. CONFORM TO ALL REQUIREMENTS INDICATED IN CIVIL DRAWINGS AND SPECIFICATIONS. 6. REFER TO SHEET E102 AND COMMUNICATION FLOOR PLANS FOR QUANTITY OF CONDUITS. 7. COORDINATE ROUTING WITH PLUMBING AND STRUCTURAL ELEMENTS. ROUTE CONDUITS BELOW FOOTINGS OR PROVIDE SLEEVES IN FOOTINGS PER STRUCTURAL DETAILS. TYPICAL DUCT BANK DETAIL SCALE: NONE nnizinin izninomini cr!E NOTES AND LANDSCAPING NAL REQUIREMENTS. E NOTES E NOTES NOTES: 1. COORDINATE WITH LANDSCAPE ARCHITECT/DRAWINGS FOR ADDITIONAL DETAILS. 2. GATE HARDWARE AND ACCESS CONTROLS SHALL UTILIZE THE FOLLOWING DISTRICT STANDARD PRODUCTS: 2.1. COMPATIBLE ELECTRIC STRIKE 9600-630 H.E.S. 2.2. SEE SPECIFICATIONS FOR CARD READER AND ADDITIONAL ACCESS CONTROL REQUIREMENTS. 3. HARDWARE SHALL BE MOUNTED AT ADA HEIGHT 42" AFG UNLESS NOTED OTHERWISE. 4. PROVIDE NEMA 3R LOCKABLE WEATHERPROOF ENCLOSURE SIMILAR TO EXISTING PHOTO FOR CABLE ROUTING. 5. PROVIDE BACK BOX AND CARD READER MOUNTED ON BACK SIDE OF WEATHERPROOF CABLE ENCLOSURE. 6. PROVIDE ALL CONDUIT STRAPS/SUPPORTS REQUIRED TO SECURELY MOUNT CARD READER/CABLE ENCLOSURE TO GATE. 7. PROVIDE ADDITIONAL HARDWARE AND ACCESS CONTROL COMPONENTS AS NEEDED TO ACCOMMODATE DISTRICT STANDARDS AND ACCESS CONTROLS SHOWN ON LANDSCAPE DRAWINGS AND INSTALL A COMPLETE AND FULLY FUNCTIONAL SYSTEM COMPATIBLE WITH CARD READER AND SPECIFIED LOCK CORES. SUBMIT ALL COMPONENTS FOR APPROVAL. 8. ALL HARDWARE AND ACCESS CONTROL COMPONENTS SHALL BE RATED FOR EXTERIOR USE. 9. SEE SPECIFICATIONS FOR ACCESS CONTROL REQUIREMENTS. GATE WITH PANIC HARDWARE DETAIL SCALE:1/2" = V-0" BP 11 1 /3/251 1 SURVEYED: DESIGNED: NS DRAWN: NS CHECKED: BP BY DATE AP P R APPROVED: BP NOTES 1,2 SCALE: CITY OF ONE INCH DATUM RENTON AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY NOTES: 1. ROUTE NEW ACCESS CONTROL CONDUIT FROM CABLE JUNCTION BOX TO NEW GATE HARDWARE. SEE SHEET E3.01 FOR PATHWAY ROUTING. ROUTE CABLING THROUGH NEW AND EXISTING PATHWAYS TO ACCESS CONTROL HEAD END IN MDF ROOM AND INTEGRATE NEW CONTROLS AND PROVIDE RE -PROGRAMMING OF EXISTING ACCESS CONTROL SYSTEM FOR A COMPLETE AND OPERABLE SYSTEM. PROVIDE CONDUIT ROUTING PLAN TO OWNER, ENGINEER, CIVIL, AND LANDSCAPE FOR APPROVAL PRIOR TO INSTALLATION. 2. PROVIDE ALL CONDUIT STRAPS/SUPPORTS REQUIRED TO SECURELY MOUNT CARD READER/CABLE ENCLOSURE TO GATE. 3. SEE SPECIFICATIONS FOR ACCESS CONTROL REQUIREMENTS. EXISTING GATE HARDWARE SCALE: NONE IN COMPLIANCE WITH CITY OF RENTON STANDARDS RSD TRANSPORTATION EXPANSION ELECTRICAL DETAILS DATE: 11/03/25 FIELDBOOK: PAGE: E901 SHEET: OF: 30 OF 30 O T T '� Y J N WA 0 0 N rr n co 0 0 N Q J RECORD DRAWING: THIS RECORD DRAWING HAS BEEN PREPARED BY METRIX ENGINEERS BASED ON AS -BUILT INFORMATION SUBMITTED, IN PART OR IN FULL, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE ARCHITECT AND ENGINEER HAVE NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND THUS SHALL NOT BE RESPONSIBLE FOR ITS ACCURACY, NOR FOR THE ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THE RECORD DOCUMENT AS A RESULT. T-434307