HomeMy WebLinkAboutzT-4343set3 O O w Q U / r- r O N 04 N O N a RECORD DRAWING: THIS RECORD DRAWING HAS BEEN PREPARED BY METRIX ENGINEERS BASED ON AS -BUILT INFORMATION SUBMITTED, IN PART OR IN FULL, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE ARCHITECT AND ENGINEER HAVE NOT T-434301 VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND THUS SHALL NOT BE RESPONSIBLE FOR ITS ACCURACY, NOR FOR THE ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THE RECORD DOCUMENT AS A RESULT. Nt O T T C) '0 Y J N WA O O O O N rr n (c) C'7 O O O N Q J 't�y� co It I C) I 0 Lu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lanning/Building/Public Works Dept. ELECTRICAL ABBREVIATIONS BP IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED::P SCALE ACCORDINGLY AND NOTES RECORD DRAWING: THIS RECORD DRAWING HAS BEEN PREPARED BY METRIX ENGINEERS BASED ON AS -BUILT INFORMATION SUBMITTED, IN PART OR IN FULL, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE ARCHITECT AND ENGINEER HAVE NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND THUS SHALL NOT BE RESPONSIBLE FOR ITS ACCURACY, NOR FOR THE ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THE RECORD DOCUMENT AS A RESULT. DATE: 11/03/25 FIELDBOOK: PAGE: E002 SHEET: OF, 25 OF 30 T-434302 0 T T C) 0 L') N WA C) 0 0 C) I Nt N co 0 C) C) I Nt N Q J w z w J Ll RECORD DRAWING: THIS RECORD DRAWING HAS BEEN PREPARED BY METRIX ENGINEERS BASED ON AS -BUILT INFORMATION SUBMITTED, IN PART OR IN FULL, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE ARCHITECT AND ENGINEER HAVE NOT T-434303 VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND THUS SHALL NOT BE RESPONSIBLE FOR ITS ACCURACY, NOR FOR THE ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THE RECORD DOCUMENT AS A RESULT. It O T T O 'O'^ L J N A u d) O O O O 4 N rr n (c) C'7 O O O 4 N Q J co It i C) i 0 Lu LUMINAIRE SCHEDULE CONSTRUCTION LIGHT SOURCE ELECTRICAL PRODUCT TYPE DESCRIPTION LENS/LOUVER MOUNTING LAMP LUMENS DOWN LUMENS UP CCT CRI BALLAST/DRIVER VOLTAGE WATTS EMERGENCY COMPONENT MANUFACTURER MODEL NOTE Si POLE LIGHT -- POLE LED 13538Im 01m 4000 K 80 REMOTE LED DRIVER, 0-10V 277 V 116 -- KIM LIGHTING 1 SA-WP9SA2-81 L-450-4K8-4W-SQ-UNV-BLT-SCH-S POLE: 22.5' HIGH 8.5" SQUARE ALUMINUM POLE. STANDARD CAP, CAST ALUMINUM SMOOTH ROUND BASE. S2 12' LIGHT COLUMN -- BOLLARD LED 10216 Im 0 Im 4000 K 80 REMOTE LED DRIVER, 0-10V 277 V 106 -- SELUX MTRCL-12-4-4B30-40-BL-277-MS ORIENT MOTION SENSOR PER DRAWINGS. INCLUDE PHOTOCELL. FND RE AR A ° 34/10356 GAS— — AS — G � , ,2 00 �i1/11 200EC o D D p O r J GV O L J I \ ®S11/11 D — o _u ° p n ) D I � C/, N (l 1/11 TYPE 1 JUNCTION BOX O 9 0 I / S1 J 1H1/ ® / 1" C SD De a I 5 °1 � S89°02'47"E 106.47' Si 9 ° \ 1H1/9 I n 34— a I � lald I I AN CAP T.S.A. v' ' — H GAS GAS GAS -- -----34 -- — — — — — S89°00'57"E 259.57 — — O n� H/ a9 0 ill 2„C N 0 0 �� cn Si 0� I 1H1/9 I D. ° $I I �mal I ill p I I TYPE 1 o W I JUNCTION BOX I 00 1 D I I S89°02' 7" E 106.20' I _0 I 0 I; I I 1H1/9 TYPE 1 I o JUNCTION BOX q 1 L9-EV/ 1 I 0 I 0 �� 1" C 1H1/9 I D \ p TYP 6 � \ JUN ION BOX 1 1/7 / WAC 51-50-0429 EV CHARGING INFRASTRUCTURE OCCUPANCY TYPE GROUP B # OF STAFF PARKING STALLS 45 # OF ACCESSIBLE PARKING STALLS 1 EV CHARGING STATIONS (10%) 5 EV-READY PARKING SPACES (10%) 5 EV-CAPABLE PARKING SPACES (10%) 5 # OF EV CHARGING STATIONS 6 # OF EV-READY PARKING SPACES 6 # OF EV-CAPABLE PARKING SPACES 5 # OF ACCESSIBLE EV CHARGING PARKING SPACES 1 NOTES: PROVISIONS SHALL APPLY ONLY TO DESIGNATED EMPLOYEE PARKING SPACES 1) FOR GROUPS A, E, AND M OCCUPANCIES. A MINIMUM 40-AMPERE DEDICATED 208/240V BRANCH CIRCUIT SHALL BE 2) INSTALLED FOR EACH EV READY PARKING SPACE AND EV CHARGING STATION. BRANCH CIRCUITS SHALL TERMINATE IN A JUNCTION BOX FOR EV READY PARKING 3) SPACES OR AT EV CHARGING STATIONS. RACEWAY CAPABLE OF ACCOMODATING A 40-AMPERE DEDICATED 208/240V 4) BRANCH CIRCUIT SHALL TERMINATE IN A JUNCTION BOX FOR EACH EV-CAPABLE PARKING SPACE. GENERAL NOTES: "t 0 1. BRANCH CIRCUITING INDICATED ON PLANS AND r SCHEDULES IS BASED UPON EXISTING PLANS AND r SITE OBSERVATION, CONTRACTOR TO FIELD VERIFY. C) 0 2. EQUIPMENT SHOWN IN DIAGRAMMATIC. COORDINATE L ) EQUIPMENT LOCATION WITH ARCHITECTURAL, N STRUCTURAL, CIVIL, AND LANDSCAPING PRIOR TO U INSTALLATION. 3. PROVIDE RIGID STEEL SWEEPS FOR ALL I UNDERGROUND CONDUITS 4. PROVIDE HANDHOLES AS REQUIRED FOR ALL POWER AND LIGHTING CIRCUITS. SPLICE CONDUCTORS IN HANDHOLES. REFER TO SCHEDULES ON SHEET E0.02 FOR ADDITIONAL INFORMATION. 5. PROVIDE ADDITIONAL PULL BOXES AS REQUIRED TO MINIMIZE TOTAL BEND RADIUS TO 270 DEGREES FOR POWER CONDUCTORS AND 180 DEGREES FOR LOW VOLTAGE CABLING. SIZE PULL BOXES PER NEC. 6. PROVIDE 1"C, 2#10, 1#10 EGC TO ALL NEW POLE O LUMINAIRES. 0 FLAG NOTES: � PROVIDE (1) 1-1/2"C, 2#1, 1#6 FROM EV CHARGING VAULT TO EV CHARGING STATION. 2� PROVIDE (1) 1-1/2"C, 2#4, 1#10 FROM EV CHARGING VAULT TO EV READY PARKING SPACE HAND HOLE. PROVIDE STUB -UP AND CAP FOR FUTURE EV CHARGING STATION. [3 PROVIDE (1) 1-1/2"C WITH PULL STRING TO EV CAPABLE HANDHOLE. PROVIDE STUB -UP AND CAP FOR FUTURE EV CHARGING STATION. PROVIDE OLDCASTLE PRECAST 233-BL VAULT � WITH 23-2436P NON-SKID COVER FOR EV � CHARGING VAULT. co 0 PROVIDE ROUGH -IN FOR A FUTURE POLE � MOUNTED SECURITY CAMERA. COORDINATE MOUNTING HEIGHT WITH OWNER PRIOR TO I INSTALLATION. PROVIDE 1" CONDUIT FROM NEW N LIGHT POLE BASE TO EXISTING POLE BASE Q DENOTED BY FLAG NOTE 7 AND INTERCEPT EXISTING SECURITY CAMERA CONDUIT. PROVIDE PULLSTRING IN NEW AND EXISTING CONDUIT J BACK TO MDF ROOM. EXISTING LIGHT POLE. 7� EXISTING SECURITY CAMERA MOUNT ON LIGHT POLE. 4 I U PROVIDE OFCI CARD READER AND CFCI �A9f EV READ'ELECTRIC LOCK MOUNTED ON GATE. SEE DETAIL 3/E9.01. PROVIDE CONDUIT TO EXISTING ACCESS (3) 1-1/2" C 3 DOUBLE HEA CONTROL GATE HARDWARE NEAR BUILDING. o CHARGI STATI N D v PROVIDE AND ROUTE CABLING IN NEW AN EXISTING CONDUIT BACK TO MDF ROOM. ' INTEGRATE CARD READER AND ELECTRIC LOCK 2 INTO EXISTING BUILDING ACCESS CONTROL EV READY SYSTEM. REFER TO PHOTOS ON SHEET E9.01 II DOUBLE HEAD FOR ADDITIONAL INFORMATION. CHAR G / II STATION > CIRCUIT NEW LUMINAIRES TO EXISTING / II LIGHTING CIRCUIT ON PANEL 1H1. INTERCEPT / n�A AND EXTEND EXISTING CONDUIT AND EV ADY CIRCUITING FROM EXISTING LIGHT POLES TO III 2 DOUBL EAD NEW POLE LOCATIONS. �o II O O ____ --_ �q CH LING O 4 1L1X 10 PROVIDE (1) 3/4"C, 2#12, 1#12G FOR IRRIGATION S TION ----- T CONTROL CABINET CONNECTION. EV UBLE O � 1L10 2 1 L12 11 LOCATE MOTION SENSOR/PHOTOCELL ON (6)1-1/2' C I � 1 HEAD O EL 1H1 SOUTH SIDE OF LUMINAIRE. CHARGING / n STATION — 6, 95 12 LOCATE MOTION SENSOR/PHOTOCELL ON 4 XFMR 1L8X NORTH SIDE OF LUMINAIRE. �DOUBLE O � \ — - — = _ _ _ —_ — — — — — — ' 1L9 13 PROVIDE TRENCHING IN LANDSCAPING AREAS II �iEAD- — - — — — — — — — — — — — — _ — _ — — — — _ �I AND BORING UNDER CONCRETE AND ROADWAYS LI CHARGING 36 — �� �� — FOR LOW VOLTAGE PATHWAYS. REFER TO CIVIL o�q — . 9�' I EV STATION \ O� `� J - I AND LANDSCAPING FOR ADDITIONAL II I _ �� I I I INFORMATION. O O 1 I .{ I I li III 4 I 14 ROUTE CONDUIT FOR NEW ACCESS CONTROL EV DOUBLE � � r — .' I , � � � � � PATHWAY TO EXISTING ACCESS CONTROL 1 6 HEAD / �� L Ili1J Q_J \\ i JUNCTION BOX ON EXISTING GATE. PROVIDE ALL III CHARGING _ _ / CONDUIT STRAPS/SUPPORTS FOR A SECURE III STATIONS — — _ / _ = _ �4 . _ = INSTALLATION. SEE PHOTOS ON E9.01 FOR T EV O O �I� — _ — �A 3 II —� EXISTING GATE HARDWARE. 15 ROUTE (1) 2"C FROM EV VAULT TO ELECTRICAL 1 (3)2"C 15 2 ENLARGED SERVICE BUILDING ELECTRICAL ROOM ROOM FOR FUTURE DATA CABLING. �°9 E301 SCALE:1/8" = V-0" _ — — _ _ _ J 16 PROVIDE NEW 24" PANEL EXTENSION ON T P BOTTOM OF ELECTRICAL PANEL. EV SINGLE HEAD ° W B�> PROVIDE ESPEN (2) EV MODEL EVC/A48S/J18/EWG/5D/15118 AND CHARGING STATION I �3W4_:�Iq--1L9-EV (1) EVA/PED/55D/S2S DUAL -CHARGER SIDE -BY -SIDE PEDESTAL. IN COMPLIANCE WITH CITY OF RENTON STANDARDS ° 9, 9" _ — — — — RIDGE _ CHARGER SHALL COME EQUIPPED WITH CELLULAR CARD. EV L SS RIDGE _ �-- ° ---- ® o® o® °p.. — O O O 7 -- --�° 2 i-' o o =e 19.5' o o ��� I _ _ _ _FF-_36.95 I 17 PROVIDE (1) 1-1/2"C, 2#4, 1#10 FROM EV CHARGING VAULT TO EV 7 CHARGING STATION. PROVIDE ESPEN (1) EV MODEL 17 I EVC/A48S/J 1 8/EWG/5D/1 5118 AND (1) EVA/PED/55S o SERVICE BUILDING °a -LEQ UIPPED ELECTRICAL ROOM WTH CELLULAR CARD. EV CHARGER SHALL BE POWER Lb—AI SELECTABLE UP TO 40A. DETECTABLE WARNING SURFACE, PROVIDED BY RECORD DRAWINGS BP 11/3/25 SURVEYED: SCALE: OTHERS CITY OF RSD TRANSPORTATION EXPANSION DESIGNED: NS RENTON DRAWN: 1 ELECTRICAL SITE PLAN NS ONE INCH DATUM �du CHECKEDBP AT FULL SCALE Planning/Building/Public works Dept. ELECTRICAL SITE PLAN E301 SCALE:1 "=20' IF NOT ONE INCH NO. REVISION BY DATE AP P R I APPROVED: SCALE ACCORDINGLY BP RECORD DRAWING: THIS RECORD DRAWING HAS BEEN PREPARED BY METRIX ENGINEERS BASED ON AS -BUILT INFORMATION SUBMITTED, IN PART OR IN FULL, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE ARCHITECT AND ENGINEER HAVE NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND THUS SHALL NOT BE RESPONSIBLE FOR ITS ACCURACY, NOR FOR THE ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THE RECORD DOCUMENT AS A RESULT. DATE: 11/03/25 FIELDBOOK: PAGE: DRAWING NO: E301 SHEET: OF: 27 OF 30 T-434304 Nt O T T C) '0 Y J N WA O O O O N rr n (c) C'7 O O O N Q J RECORD DRAWING: THIS RECORD DRAWING HAS BEEN PREPARED BY METRIX ENGINEERS BASED ON AS -BUILT INFORMATION SUBMITTED, IN PART OR IN FULL, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE ARCHITECT AND ENGINEER HAVE NOT T-434305 VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND THUS SHALL NOT BE RESPONSIBLE FOR ITS ACCURACY, NOR FOR THE ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THE RECORD DOCUMENT AS A RESULT. 3 O 06 w Q U / r- r O N 04 N O N a RECORD DRAWING: THIS RECORD DRAWING HAS BEEN PREPARED BY METRIX ENGINEERS BASED ON AS -BUILT INFORMATION SUBMITTED, IN PART OR IN FULL, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE ARCHITECT AND ENGINEER HAVE NOT T-434306 VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND THUS SHALL NOT BE RESPONSIBLE FOR ITS ACCURACY, NOR FOR THE ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THE RECORD DOCUMENT AS A RESULT. Nt O T T C) '0 Y J N WA O O O O N rr n (c) C'7 O O O N Q J SIZE CHART POLE HT. A B 25' 72" 24" SACK EXPOSED PORTION OF POLE BASE WITH MATCHING GROUT TO FILL VOIDS AND COVER FORM MARKS COPPER EQUIPMENT GROUND CONDI ATTACH TO INTERNAL LUG WELDED II` OF POLE GROUNDED CONDUCTOR SH SAME SIZE AND TYPE AS SUPPLY CON 2" SECURITY CE (B) DIAMETER OF POLE BASE SIZED AT THE DIAMETER OF POLE BASE CANOPY PLUS 2" ABOVE BEVEL. TYPICAL POLE BASE DETAIL SCALE: NONE TYPICAL LIGHT AND POLES AS SPECIFIED POLE GROUND LUG. TERMINATE EQUIPMENT GROUNDING CONDUCTOR AND FIXTURE GROUND. TERMINATE CONDUITS AT BASE OF HAND HOLE ANCHOR BOLTS, NUTS, AND LEVELING NUTS BY POLE MANUFACTURER. COORDINATE SIZE AND SPACING WITH SUPPLIER. BEVEL 2" AT 45 DEGREES (2) #4 TIES AT 2" O.C. AT TOP GRADE GROUNDING ELECTRODE CONDUCTOR IN 1/2"C, IRREVERSIBLE CONNECTION AT POLE GROUND LUG, EXOTHERMIC WELD AT GROUND ROD. SEAL BELOW GRADE. INSTALL 1/2" X 10'-0" COPPER GROUND ROD REINFORCING RODS 4#4 VERTICAL WITH 2" MINIMUM COVER & #4 TIES AT 16" O.C. THROUGH DEPTH OF BASE. INSTALL ANCHOR BOLTS AS RECOMMENDED BY POLE MANUFACTURER CONDUIT(S)-REFER TO PLANS. FOR DIRECT BURIED CABLE APPLICATIONS PROVIDE 90' DOWN SWEEP WITH BUSHED ENDS AND SEALED. CONCRETE POLE BASE RECORD DRAWINGS w w NO. REVISION FINISHED GRADE BURIED IDENTIFICATION TAPE UNDISTURBED EARTH BACKFILL - PLACE AND COMPACT IN 8" LAYERS SAND N]nTF.q- 1. CONDUIT SHALL HAVE A MINIMUM OF 36" OF COVER. 2. PROVIDE A MINIMUM OF 12" HORIZONTAL SEPARATION BETWEEN CONDUIT AND OTHER UTILITIES. 3. CONDUIT SHALL BE 4" SCHEDULE 40, LION. 4. COORDINATE WITH UTILITY COMPANIES FOR ALL REQUIREMENTS. 5. CONFORM TO ALL REQUIREMENTS INDICATED IN CIVIL DRAWINGS AND SPECIFICATIONS. 6. REFER TO SHEET E102 AND COMMUNICATION FLOOR PLANS FOR QUANTITY OF CONDUITS. 7. COORDINATE ROUTING WITH PLUMBING AND STRUCTURAL ELEMENTS. ROUTE CONDUITS BELOW FOOTINGS OR PROVIDE SLEEVES IN FOOTINGS PER STRUCTURAL DETAILS. TYPICAL DUCT BANK DETAIL SCALE: NONE nnizinin izninomini cr!E NOTES AND LANDSCAPING NAL REQUIREMENTS. E NOTES E NOTES NOTES: 1. COORDINATE WITH LANDSCAPE ARCHITECT/DRAWINGS FOR ADDITIONAL DETAILS. 2. GATE HARDWARE AND ACCESS CONTROLS SHALL UTILIZE THE FOLLOWING DISTRICT STANDARD PRODUCTS: 2.1. COMPATIBLE ELECTRIC STRIKE 9600-630 H.E.S. 2.2. SEE SPECIFICATIONS FOR CARD READER AND ADDITIONAL ACCESS CONTROL REQUIREMENTS. 3. HARDWARE SHALL BE MOUNTED AT ADA HEIGHT 42" AFG UNLESS NOTED OTHERWISE. 4. PROVIDE NEMA 3R LOCKABLE WEATHERPROOF ENCLOSURE SIMILAR TO EXISTING PHOTO FOR CABLE ROUTING. 5. PROVIDE BACK BOX AND CARD READER MOUNTED ON BACK SIDE OF WEATHERPROOF CABLE ENCLOSURE. 6. PROVIDE ALL CONDUIT STRAPS/SUPPORTS REQUIRED TO SECURELY MOUNT CARD READER/CABLE ENCLOSURE TO GATE. 7. PROVIDE ADDITIONAL HARDWARE AND ACCESS CONTROL COMPONENTS AS NEEDED TO ACCOMMODATE DISTRICT STANDARDS AND ACCESS CONTROLS SHOWN ON LANDSCAPE DRAWINGS AND INSTALL A COMPLETE AND FULLY FUNCTIONAL SYSTEM COMPATIBLE WITH CARD READER AND SPECIFIED LOCK CORES. SUBMIT ALL COMPONENTS FOR APPROVAL. 8. ALL HARDWARE AND ACCESS CONTROL COMPONENTS SHALL BE RATED FOR EXTERIOR USE. 9. SEE SPECIFICATIONS FOR ACCESS CONTROL REQUIREMENTS. GATE WITH PANIC HARDWARE DETAIL SCALE:1/2" = V-0" BP 11 1 /3/251 1 SURVEYED: DESIGNED: NS DRAWN: NS CHECKED: BP BY DATE AP P R APPROVED: BP NOTES 1,2 SCALE: CITY OF ONE INCH DATUM RENTON AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY NOTES: 1. ROUTE NEW ACCESS CONTROL CONDUIT FROM CABLE JUNCTION BOX TO NEW GATE HARDWARE. SEE SHEET E3.01 FOR PATHWAY ROUTING. ROUTE CABLING THROUGH NEW AND EXISTING PATHWAYS TO ACCESS CONTROL HEAD END IN MDF ROOM AND INTEGRATE NEW CONTROLS AND PROVIDE RE -PROGRAMMING OF EXISTING ACCESS CONTROL SYSTEM FOR A COMPLETE AND OPERABLE SYSTEM. PROVIDE CONDUIT ROUTING PLAN TO OWNER, ENGINEER, CIVIL, AND LANDSCAPE FOR APPROVAL PRIOR TO INSTALLATION. 2. PROVIDE ALL CONDUIT STRAPS/SUPPORTS REQUIRED TO SECURELY MOUNT CARD READER/CABLE ENCLOSURE TO GATE. 3. SEE SPECIFICATIONS FOR ACCESS CONTROL REQUIREMENTS. EXISTING GATE HARDWARE SCALE: NONE IN COMPLIANCE WITH CITY OF RENTON STANDARDS RSD TRANSPORTATION EXPANSION ELECTRICAL DETAILS DATE: 11/03/25 FIELDBOOK: PAGE: E901 SHEET: OF: 30 OF 30 O T T '� Y J N WA 0 0 N rr n co 0 0 N Q J RECORD DRAWING: THIS RECORD DRAWING HAS BEEN PREPARED BY METRIX ENGINEERS BASED ON AS -BUILT INFORMATION SUBMITTED, IN PART OR IN FULL, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE ARCHITECT AND ENGINEER HAVE NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF THE INFORMATION PROVIDED AND THUS SHALL NOT BE RESPONSIBLE FOR ITS ACCURACY, NOR FOR THE ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THE RECORD DOCUMENT AS A RESULT. T-434307