AMENDMENT NO. 5 TO AGREEMENT CAG-20-031 FOR THE
RAINIER AVE. AND OAKESDALE AVE. STORMWATER PUMP
STATION UPGRADES PROJECT
THIS AMENDMENT, dated for reference purposes only as June 6, 2025, is by and between the
City of Renton (the "City"), a Washington municipal corporation, and RH2 Engineering, Inc.
("Consultant"), a Washington corporation. The City and the Consultant are referred to collectively
in this Amendment as the "Parties." Once fully executed by the Parties, this Amendment is
effective as of the last date signed by both parties.
Whereas, the City engaged the services of the Consultant under Agreement CAG-20-031, dated
January 24, 2020, to provide necessary services for the Rainier Ave. and Oakesdale Ave.
Stormwater Pump Station Upgrades Project (referred to herein as the "Agreement");
Whereas, the Parties wish to amend the Agreement to add additional scope of work, and to add
additional compensation, in order to add services associated with the replacement of the pump
at the Rainier Ave S Pump Station .
NOW THEREFORE, it is mutually agreed upon that CAG-20-031 is amended as follows:
1.Scope of Work: Section 1, Scope of Work, is amended to include additional technical
evaluation, and design and drafting services, as specified in Exhibit A-5, which is attached
and incorporated herein.
2.Compensation: Section 4, Compensation, is amended so that the maximum amount of
compensation payable to Consultant is increased by $42,000 from $252,650 to $294,650,
plus any applicable state and local sales taxes. The additional compensation shall be paid
based upon Work actually performed according to the rate(s) or amounts specified in
Exhibit B-5, which is attached and incorporated herein.
3.All terms of the Agreement not explicitly modified herein shall remain in full force and
effect and such terms shall apply to Work performed according to this Amendment as if
fully set forth herein.
IN WITNESS WHEREOF, the Parties have voluntarily entered into this Amendment as of the date
last signed by the Parties below.
CAG-20-031, Adden #5-25
6/16/2025
n/a
Approved by Cheryl Beyer via email 6/15/2025
1
5/13/2025 8:50:47 AM J:\DATA\REN\119-215\00 CONTRACT\AMEND NO. 5\AMND_NO. 5_EXH A-5_SOW_RAINIER SWPS FINAL DESIGN.DOCX
EXHIBIT A-5
Scope of Work
City of Renton
Rainier and Oakesdale Stormwater Pump Stations
Alternatives and Feasibility Evaluation
Amendment No. 5 to CAG-20-031
Rainier SWPS Final Design and Services During Bidding
May 2025
Background
The City of Renton (City) retained RH2 Engineering, Inc., (RH2) to perform an alternatives evaluation
of its Rainier and Oakesdale Stormwater Pump Stations (SWPS). The Rainier SWPS was constructed
in the 1960s. Itselectrical equipment is from the original construction and does not meet the current
electrical code with regards to the location in a Class 1, Division 2 area. To meet current electrical
code, new electrical equipment will need to be relocated to a separate electrical building or under a
shelteroutside of the classified area.In addition to electrical equipment upgrades, the City requested
RH2 evaluate alternatives for equipping the station with a permanent emergency generator.
Based on the alternatives evaluation and preliminary design prepared by RH2, the City has chosen to
locate the emergency generator for the Rainier SWPS within the Rainier Avenue right-of-way (ROW),
just south of the existing pump station. Improvements also will include upgrades to the existing
electrical system. The City recently determined that the existing pumps are aging and replacement
parts are becoming difficult to source. This Scope of Work includes evaluation of the wet well and
pump cycling, updating the design to include replacement of the pumps and associated mechanical
and electrical components, and reevaluation of the generator to determine whether the size can be
reduced with the replacement pumps and motor starters.
This Scope of Work presumes that there will be minimal impact to the rest of the design and no
substantial redesign will need to occur for the pumps to be replaced as part of the project.
Task 8A 90-Percent Plans, Specifications, and OPCC for Pump Replacement
Objective: Update the design to include replacement of the existing pumps. Prepare 90-percent
design plans, general and technical specifications, and opinion of probable construction costs (OPCC)
for the pump replacement. Perform internal quality assurance and quality control (QA/QC) review
and submit 90-percent design documents to the City for review.
Approach:
Select replacement pumps to replace the aging pumps within the existing wet well. Advance
the pump replacement design plans to 90 percent. Attend one (1) site visit to confirm piping
and the planned replacement.
City of Renton Exhibit A-5
Rainier and Oakesdale Stormwater Pump Stations Scope of Work
Rainier SWPS Final Design and Services During Bidding Amendment No. 5
2
5/13/2025 8:50:47 AM J:\DATA\REN\119-215\00 CONTRACT\AMEND NO. 5\AMND_NO. 5_EXH A-5_SOW_RAINIER SWPS FINAL DESIGN.DOCX
Develop 90-percent specifications for the proposed pumps and associated piping and electrical
equipment.
Update the OPCC to include work associated with the pump replacement.
Perform an analysis of the existing wet well with the new pumps to determine if the pump
.
Assumptions:
The pumps, motor starters, and piping will be replaced up to the existing check valves.
No structural modifications to the building or floor slab will be required as part of the
replacement of the pumps.
Access hatches will be installed on a new concrete curb placed around the existing slab
openings.
RH2 Deliverables:
Updated 90-percent review plans, technical specifications, and OPCC for the replacement
pumps in electronic PDF.
One (1) email summarizing the analysis of the wet well and pump cycling.
Task 9A Bid-Ready Design for Pump Replacement
Objective: Develop bid-ready design plans, specifications, and OPCC for the Rainier SWPS
improvements pump replacement.
Approach:
Incorporate City comments from the 90-percent review meeting and internal QA/QC review on
the pump replacement into the bid-ready design plans and specifications. Review non-technical
specifications provided by the City.
Prepare bid-ready OPCC.
Assumptions:
The City will combine the non-technical and technical specifications ahead of advertising the
project for bids.
RH2 Deliverables:
Bid-ready plans, technical specifications, and OPCC in electronic PDF.
City of Renton Exhibit A-5
Rainier and Oakesdale Stormwater Pump Stations Scope of Work
Rainier SWPS Final Design and Services During Bidding Amendment No. 5
3
5/13/2025 8:50:47 AM J:\DATA\REN\119-215\00 CONTRACT\AMEND NO. 5\AMND_NO. 5_EXH A-5_SOW_RAINIER SWPS FINAL DESIGN.DOCX
Fee for Services
RH2 estimates this additional work to be $42,000 as shown in Exhibit B-5.
Schedule
The schedule for each Task is outlined in Exhibit C-5 for this Scope of Work.
Docusign Envelope ID: 2485F9D8-60ED-4AB8-9DF9-88D142881980
Washington State Department of Transportation
August 13, 2024
RH2 Engineering, Inc.
22722 29th Drive SE, STE 210
Bothell, WA 98021
Subject: Acceptance FYE 2023 ICR-Risk Assessment Review
Dear Leilani McSpadden:
Development Division
Contract Services Office
PO Box 47408
Olympia, WA 98504-7408
7345 Linderson Way SW
Tumwater, WA 98501-6504
TTY: 1-800-833-6388
www.wsdot.wa.gov
Based on Washington State Department of Transportation's (WSDOT) Risk Assessment review
of your Indirect Cost Rate (ICR), we have accepted your proposed FYE 2023 ICR of 201.71 % of
direct labor. This rate will be applicable for WSDOT Agreements and Local Agency Contracts in
Washington only. This rate may be subject to additional review if considered necessary by
WSDOT. Your ICR must be updated on an annual basis.
Costs billed to agreements/contracts will still be subject to audit of actual costs, based on the terms
and conditions of the respective agreement/contract.
This was not a cognizant review. Any other entity contracting with your firm is responsible for
determining the acceptability of the ICR.
If you have any questions, feel free to contact our office at (360) 704-6397 or via email
consultantrates@wsdot.wa.gov.
Regards,
chatz e Harve
Schatzie Harvey (Aug 13, 2024 13:23 PD
SCHATZIE HARVEY, CPA
Contract Services Manager
SH:kb
Docusign Envelope ID: 2485F9D8-60ED-4AB8-9DF9-88D142881980
EXHIBIT B -5
Fee Estimate
Amendment No. 5 to CAG-20-031
City of Renton
Rainier and Oakesdale Stormwater Pump Stations
Alternatives and Feasibility Evaluation
Rainier SWPS Final Design and Services During Bidding
May-25
Description
Task SA 90-Percent Plans, Specifications, and OPCC for Pump Replacement
8.6 Select replacement pumps and attend site visit
8.7 Develop 90% specifications
8.8 Update OPCC
8.9 Perform analysis of existing wet well
Task9A Bid-Ready Design for Pump Replacement
9.3 Incorporate City's 90% review comments
9.4 Prepare bid-ready OPCC
PROJECT TOTAL
J:\Data\REN\119-215\00 Contract\Amend No. 5\Amnd_No. S_EXH B-S_FEE_Rainier SWPS Final Design
Total
Hours
$
76 $
26 $
10 $
14 $
$
34 $
12 $
is 112 I$
Total Total Expense Total Cost
Labor
28,596 $ 2,206 $ 30,802
17,252 $ 1,399 $ 18,651
5,932 $ 396 $ 6,328
2,376 $ 169 $ 2,545
3,036 $ 241 $ 3,277
10,206 $ 993 $ 11,199
7,360 $ 812 $ 8,172
2,846 $ 181 $ 3,027
38,802 I $ 3,198 I $ 42,0001
5/13/2025 12:15 PM
1
5/13/2025 8:47:00 AM J:\Data\REN\119-215\00 Contract\Amend No. 5\Amnd_No. 5_EXH C-5_Schedule_Rainier SWPS Final Design.docx
-
Rainier and Oakesdale Stormwater Pump Stations
Alternatives and Feasibility Evaluation
Amendment No. 5 to CAG-20-031
Rainier SWPS Final Design and Services During Bidding
ANTICIPATED NOTICE TO PROCEED DATE: May 2025
Task 8A 90-Percent Plans, Specifications, and OPCC for Pump
Replacement June 2025
Pump replacement selection and site visit
Develop 90-percent specifications
Update OPCC
Perform analysis of existing wet well
Reevaluate generator sizing
Task 9A Bid-Ready Design for Pump Replacement January 2026
Incorporate 90-percent review comments
Prepare bid-ready OPCC
ANTICIPATED CONTRACT COMPLETION DATE: July 2026