Loading...
HomeMy WebLinkAboutR-434408lqt DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 co I I W I- 2 2 MAX. LEVEL BOTTOM MAX, 1 1 F 12" MIN. �- 2' MIN. -� -� SWALE SPACING DEPENDS ON SLOPE GRADIENT NOTES: 1. CONDITIONS OF USE 1.1. REQUIRED AT: 1.1.1. THE TOP OF ALL SLOPES IN EXCESS OF 3HAV AND WITH MORE THAN 20 FEET OF VERTICAL RELIEF. 1.1.2. AT INTERVALS ON ANY SLOPES THAT EXCEEDS THE DIMENSIONS SPECIFIED BELOW. AVERAGE SLOPE SLOPE PERCENT FLOW PATH LENGTH 20H:1 V (OR LESS) 3.5 % 300 FEET (10 TO 20)H'AV 5-10% 200 FEET (4 TO 10)H,1V 10-25% 100 FEET (2TO4)HAV 25-50% 50FEET 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. FOR SLOPES STEEPER THAN 2HAV WITH MORE THAN 10 FEET OF VERTICAL RELIEF, BENCHES MAY BE CONSTRUCTED OR CLOSER SPACED INTERCEPTOR SWALES MAY BE USED. THE DESIRED MEASURE MUST BE DESIGNED BY AN ENGINEER TO EFFECTIVELY INTERCEPT THE HIGH VELOCITY RUNOFF TO A SEDIMENT POND OR TRAP. 2.2. CONSTRUCTION TRAFFIC OVER TEMPORARY SWALES SHALL BE MINIMIZED. 3. MAINTENANCE STANDARDS 3.1. DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY. 3.2. IF THE FACILITIES DO NOT REGULARLY RETAIN STORM RUNOFF, THE CAPACITY AND/OR FREQUENCY OF THE SWALES SHALL BE INCREASED. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 217.10 • PUBLIC WORKS INTERCEPTOR SWALE PPR D. 9/28/2018 DEPARTMENT GAZ DATE RUNOFF WITH SEDIMENT 5% FILTERED RUNOFF z 0 m WATER LEVEL NTS Interceptor Swale 6"=12" PERFORATE PIPE AS NECESSARY TOP OF PIPE SHALL BE 6" MIN ABOVE GRADE PROVIDE SOLID COVER DISCHARGE TO SEDIMENT POND VIA TEMP FORCE MAIN 1 / ... 0 0 0 0 0 0 ... ... 0 0 0 ..0 . 0 0 0 0 0 0 0 0 0 0 0 ... ... 0 0 0 0 0 0 y.. - ..�� 0 C .� ... 0 C PROVIDE 12" MIN WASHED ROCK AROUND PERIMETER OF PIPE WRAP WITH PERMEABLE FILTER FABRIC 24"-36" PVC OR HDPE PIPE W/ 2" DIA WEEP HOLES OR APPROVED EQUAL WIRE TIES SUMP PUMP AND MOTOR CONCRETE BLOCKS :45 AN NTS _( Temporary Sump and Pump JACOBSON Jr. CONSULTING ENGINEERS DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 2"x2" 14 GAUGE WIRE, OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC 7 MIN. 6' MAX. 1r MIN. POST SPACING MAY BE INCREASED I I I 4'x4" MIN. TRENCH TO T IF WIRE BACKING IS USED I I I I� ;UI BACKFILL TRENCH WITH NATIVE SOIL OR 3l4" TO 1-112' WASHED GRAVEL 2"x4" WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP.) NOTES: 1. CONDITIONS OF USE 1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. AOS (ASTM D4751) 30-100 SIEVE SIZE (0.60-0.15mm) FOR SILT FILM 50-100 SIEVE SIZE (0.30.0.15mm) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D4491) 0.02 SEC-' MINIMUM GRAB TENSILE STRENGTH (ASTM D4632) 180 LBS. MIN. FOR EXTRA STRENGTH FABRIC 100 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM 1)4632) 30% MAX. (WOVEN) ULTRAVIOLET RESISTANCE (ASTM D4355) 70% MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V 2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4"X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3. MAINTENANCE STANDARDS 3.1, ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY, 3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS. REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 3.4. SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 214.00 1DR) PUBLIC WORKS SILT FENCE PR 9/28/2018 1 DEPARTMENT GAZ DATE NTS Silt Fence 5/8" WIRE ROPE PROVIDE SECURE 1 END ATTACHMENT AT CORNER AND GATE POSTS AND PROVIDE RUNNING ATTACHMENT AT LINE POSTS AND NEAR CENTER OF EACH FENCE PANEL TRUSS ROD 3/8" DIA TOP RAIL W/ TENSION DEVICE 1.666 INCH O.D. STRETCHER LINE POST (TYP) BAR 2.375 INCH O.D. BRACE RAIL J TENSION WIRE AND CABLE CONCRETE BLOCK 1.666 INCH O.D. STD WGT GALVANIZED CORNER POST NTS Construction Fencing CIVIL CONSTRUCTION PERMIT 43667 IST1 g�1 NAL NO. REVISION :45 Al` DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 aOPO R = 25' MIN. �- INSTALL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT, AS PER CITY ROAD STANDARDS 4"-B" QUARRY SPALLS GEOTEXTILE 12" MIN. THICKNESS 100' MIN. 1. DRIVEWAYS SHALL BE PAVED TO THE EDGE OF THE RIGHT-OF-WAY PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY. 2. IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD 15' MIN. PROVIDE FULL WIDTH OF INGRESSIEGRESS AREA NOTES: 1. CONDITION OF USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. 1.2. FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION ENTRANCE. STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTHANIDTH TO PROVIDE VEHICLE ACCESSIPARKING, BASED ON LOT SIZE/CONFIGURATION. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXTILE SHALL MEET THE FOLLOWING STANDARDS: GRAB TENSILE STRENGTH (ASTM D4632) 200 LBS. MIN. GRAB TENSILE ELONGATION (ASTM D4632) 30 % MAX. (WOVEN) CBR PUNCTURE STRENGTH (ASTM D6241) 495 LBS. MIN. ADS (ASTM D4751) 20-45 (U.S. STANDARD SIEVE SIZE) 2.2. DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE pH LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED. 2.3. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT. 2.4. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. 2.5. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3. MAINTENANCE STANDARDS 3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE. OR THE INSTALLATION OF A WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. 3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY, IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS. 3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCEIS), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 215.10 CRAPv� PUBLIC WORKS STABILIZED CONSTRUCTION ENTRANCE GYAZ 9/28/2018 I DEPARTMENT DATE NTS Stabilized Construction Entrance :45 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 TREE PROTECTION ZONE (TPZ) FENCE DETAIL PROTECTION MEASURES DURING CONSTRUCTION: 1. Chain link fencing is required around the drip line of trees required to be retained, or around required tree protection tracts/easements. 41. 2. The fence shall be a minimum of 6-feet high. 3. Steel posts shall be driven at a depth to ensure the fence remains in an upright position for the duration of the development.p 4. Tree protection signage shall be placed at intervals of no d'Y y more than 20-feet along the entire fence. See link below f for signage specifications. �' ti y ti" 5. Storage, fill, excavation, earth compaction, or dumping of liquids or materials is prohibited in fenced area. 6-FOOT 6. Utilities or impervious surface installation is prohibited REQUIRED tip, CHAIN LINK within the tree drip line. SIGNAGE FENCE 7. Grade changes are prohibited within the tree drip line. 8. Removal of the existing vegetation within the drip line of TREE protected trees is prohibited. PROTECTION 9, All areas within the required fencing shall be covered SIG ................... evenly with a minimum of 3-inches of bark mulch, except in areas where mulch will adversely affect protected 1 ground cover plants. 10. For protected trees subject to a land use decision, the applicant shall retain an ISA certified arborist or ASCA UNDISTURBED certified consultant to supervise fence installation, DRIVEN STEEL MAINTAIN monitor tree health, and prune trees. POSTS EXISTING VEGETATION WITH 3-INCHES GRADE MULCH IN /21/25 JAJ SURVEYED: IN /14/25 JAJ DESIGNED: ACW IN/06/25 JAJ DRAWN: DJD/AJJ CHECKED: JAJ BY DATE APPR APPROVED: JAJ CITY OF Planning Division Renton O 1055 South Grady Way Renton, WA 98057 425-430-7200 I www.rentonwa.gov PAGE 1 OF 3 SCALE: 1"=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 5" MAX. DRAINAGE GRATE TRIM GRATE FRAME _ C_ OVERFLOW BYPASS i BELOW INLET GRATE DEVICE SEDIMENT AND DEBRIS ' b FILTERED WATER SECTION VIEW DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) RETRIEVAL SYSTEM (TYP.) OVERFLOW BYPASS (TYP.) BELOW INLET GRATE DEVICE ISOMETRIC VIEW NOTES: 1. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE. 5. THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS). 6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15). 8. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY, UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 216.30 •• PUBLIC WORKS APPR ED: sI� DEPARTMENT CATCH BASIN INSERT GqZ 9/2s/2o1s DATE NTS Inlet Protection ROCK MUST COMPLETELY COVER THE BOTTOM AND SIDES OF THE DITCH 6" MIN. 24" MIN. CROSS SECTION 2H:1V SLOPES LAL STANCE SUCH THAT POINTS RE OF EQUAL ELEVATION B ` 2"- 4" ROCK L T / CHECK DAM SPACING :45 A' NTS(: n Check Dam a IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Ar% IL HBray 06/24/2025 0:] NTS Tree Protection CITY OF RENTON . Planning/Building/Public Works Dept. LINDBERGH HIGH SCHOOL FIELD IMPROVEMENTS TESC DETAILS DATE: 02-21-25 FIELDBOOK: PAGE: DRAWING NO: C110 SHEET: OR 8 OF 42 d� O O N �J W O O C) O II L J N r�1 /- LJ O O C) O 1 L J N J R-434408