Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
R-434422
3 v d x x N N Z w U m m m r J 0 .3 O m m m m m In r i (D li U 2 Ii C U 1' W J 4 rr C. — FIEL L�GkIT =_— ----- — �\ � L�'OL - - G NOTE LEGEND (�'•) W� TE N 5 S 1. (INDICATES GENERAL CONSTRUCTION NOTE) / — G (TYP. F222 \ \ — — " 3O (INDICATES SPECIFIC CONSTRUCTION KEYNOTE) CY)/ / / / I I //� FENCE C — __-------------------------- O� o �� o __! LAYOUT AND FENCING NOTES o LO Q / / — — /' QUICK COUPLING I R�gC�CY ) \ - O FURNISH AND INSTALL PERMEABLE AGGREGATE AND SYNTHETIC TURF EDGE ANCHORING SYSTEM AROUND THE ENTIRE w / / / G// f / / / / / BROWN SYNTHETIC 9 VALVE (TYP.) �\ \ \ \ W /' PERIMETER OF THE SYNTHETIC TURF FIELD AREAS INCLUDING BASE BID BATTING CAGES. N TURF WARNING O \ \ \ \ \ ' W `J 2. PRIOR TO INSTALLATION OF ANY IMPROVEMENTS AT THE BASEBALL AND SOFTBALL INFIELD CONTRACTOR SHALL ACCURATELY TRACK (TYP.) �_ O SURVEY AND FIELD CONFIRM THE LOCATION OF HOME PLATE, 1st, 2nd AND 3rd BASE, FOUL POLE AND FOUL LINE. U � \ — - CONFIRMATION AND SUBSEQUENT CONSTRUCTION, INCLUDING INSTALLATION OF NEW FOUL POLES, BASE ANCHORS, AND PLATES, SO THAT FIRST AND THIRD BASE LINES RESULT IN AN INTERNAL 90 DEGREE ANGLE, AND THAT LOCATION OF FOUL POLES REPRESENT A TRUE EXTENSION OF EACH FOUL LINE. 12.00' ( I IYIWT EI T FED (� 3. RESTORE ALL DISTURBED NON SURFACE PERIMETER AREAS. I / /WARNING I / ' ' ♦ TACK (TYP.) NICH T ISTI 1 _ I 0FOUL POLES ARE LOCATED IN FAIR TERRITORY, COORDINATED WITH THE PLACEMENT OF HOME PLATE AT THE DISTANCES I /48" 'P�'/ ON g IU B I INDICATED. OUTSIDE FACE OF BOTH POLES TO FORM A 90 DEGREE ANGLE WITH THE BACK OF HOME PLATE AT THE APEX. / 'T i /d / .1 ' I I I 1 ` O NEW PAVING TO MEET AND MATCH FLUSH WITH EXISTING ADJACENT SURFACES WHERE INDICATED. / g / STORMTECH DETENTION \ \ 00 OUTFIELD FENCE 14 CHAMBERS, SEE CIVIL PLANS I I F�2 11 I Il ) o / c 6. SEE ELECTRICAL SHEETS FOR CONDUIT TO SCOREBOARDS, LIGHTS AND POWER SUPPLY TO THE BATTING CAGES. r WINDSCREEN C)/ 7. RESTORATION LIMIT SHOWN IS THE MINIMUM ANTICIPATED LIMIT OF DISTURBANCE. ANY ADDITIONAL DISTURBANCE CREATED C) 3 AS A RESULT OF THE CONTRACTORS WORK SHALL BE RESTORED AS DIRECTED WITHOUT ADDITIONAL COMPENSATION EXCEPT LPE ITCH R1 S \ AS AGREED IN ADVANCE OF THE INITIAL DISTURBANCE. RESTORATION SHALL BE TO A LIKE CONDITION. GREEN \ f II F250 \ SYNTHETIC r \� 8. THE CONTRACTOR SHALL FIELD VERIFY SYNTHETIC TURF SURFACING DIMENSIONS TO MATCH EXISTING FIELD AREA. SEE L6 ,TE ATE B #1 / I I o SYNTHETIC TURF COMPOSITE PLAN AND LAYOUT PLANS & DETAILS FOR SYNTHETIC TURF LINES AND MARKINGS. CV COREBO R AID U T ON�1/ / TURF (TYP.) GREEN �._._.!._._. m f I SEE ARCH A L S F6ft I 9. INSTALL NEW QUICK COUPLING VALVE IN TURFCOOL VALVE BOX. F0, � D al I OR ON / f 1 SYNTHETIC I I I �I o O o- / / / TURF (TYP.) ' I 10. COORDINATE FENCE POST LOCATIONS TO AVOID EXISTING OR PROPOSED UTILITIES. ONCTE a 0) FURNISH AND INSTALL DUGOUTS COMPLETE FOR THE BASEBALL AND SOFTBALL FIELDS. R ( RETAIN NG I 12. REMOVE AND REPLACE THE LOWER 10' OF CHAIN LINK FENCE FABRIC BETWEEN THE ENDS OF THE DUGOUTS USING NEW 6 J CURB I 0 GAUGE GALVANIZED WIRE FABRIC. 13. PROVIDE NEW BACKSTOP BOARDS AND PADS AS SHOWN. PROVIDE NEW FENCE SAFETY CAP AT ALL FENCES 10' HT. AND UNDER, AND 120 LF OF WINDSCREEN CENTERED ON CENTER FIELD. 15. PROVIDE EXPANSION FOR ALL CONCRETE PAVING AT 40' ON CENTER. PROVIDE CONTROL JOINTS AND CONCRETE SCORING SYNTHTITURF E E C DG E I o PATTERN AT ALL FENCE POST LOCATIONS AT 10' ON CENTER. ANCHOR AT EXISTING CONCRETE CURB \EW \ � EET ANND MATCHCRETE FENCE TYPE KEY I EXISTING CONCRETE PAVING 5O /S \ A 25' OVERALL 10' HEIGHT CHAIN LINK FENCE 2" MESH X9 � I�p l GAUGE, TOP, MIDDLE, BOTTOM RAIL, 15' X2"SQ. BLOCK \ti C NYLON NETTING ABOVE RETAININ FIELD L}GHf W LL © 10' HEIGHT CHAIN LINK FENCE; 2" MESH X9 GAUGE, TOP, / ATYPI) / I I) I I o MIDDLE, BOTTOM RAIL I REPLACE NETTING AMP HANDR ID, � �� ON EXISTING I I I I I I \ E C VIL PLANS 270 © 4 HEIGHT CHAIN LINK FENCE, 2 MESH x9 GAUGE, TOP AND I I I \ CABLE (TYP.) � BOTTOM RAIL I I I I I\ \ I �\ L��RADI G BATTING CAGE NET TUNNEL LfjA SITION AT I�Ly G (TYP. I I \ EO REPLACE BACKSTOP STOP BOARDS &PADS (FIELD VERIFY) 11ST1NG 90.00, , LL ONT OL NETTI� , GATE TYPE KEY(ALL CHAIN LI N (TYP) K � ER FENC NG WITH F -�, I I O 5' SINGLE SWING GATENEB G�TY-P•j GREEN YNTHETIC TURF (TYP.) GREEN �YNTHETIC \ , ___ LAYOUT AND FENCING LEGEND I I I I 1 TURF (TYP.)12.00' CONCRETE I I I \ k I _ --- �f I I\ WARNING F210 1 ME WALL I I I I O� '' \\/I' o � GREEN SYNTHETIC TURF AND B FENCE TYPE AND LIMIT \ TRACK (TYP.) F210 SYNTHETIC TURF I / % PERMEABLE AGGREGATE 12 � I I / \ PITCHING MOUND ' /' I / / i� 3 GATE TYPE �O \ BROWN BROWN SYNTHETIC TURF AND SYNTHETIC 5 \\ T / " ; PERMEABLE AGGREGATE I TURF (TYP.) F220 � / /jv- \IIon /%� / / l / CONCRETE PAVING �QU I CIK C'0 UPIhN-G"' F210 ' 1 DUGOUT I/ // ///� VALVE (*P.) � STRUCTURE � _ 'r F240 / / ' NEW SYNTHETIC TURF EDGE ANCHOR \ I— I BROWN SYNTHETIC 11 (TYP) I LF // //// / — / / i M M M ON EXISTING CONTAINMENT CURB \\ TURF WARNING / TYPICAL BASE BASEBALL ® / / / / / r A0 \ F260 • TRACK (TYP.) 1 - - _ _ _ _ _ - AND PLATE MARKINGS IL ` -- 9 CHAIN LINK FENCE F222 ANCHOR LAYOUT (TYP.) F310 1 pLOATE 1 I / / /— _ I F22o LIGHT POLE, SEE ELECTRICAL g I 3 BULLPEN PITCHING BASEBALL 1 �� DSO I Q I LIPGG / / // / / / / — NETTING ON EXISTING CABLES TED I II — --F2.�0_ p�OUND BULLPEN AREA 2 BASEBALL O� V �) / / / \ F250 12 BATTERS E \ TYP. I — - — - — - F310 BOX 7`"/' / / /' / /� / CAST -IN -PLACE \� \ \ — _ — _ — _ - — 1 � / / / / / / / i �o� \ RETAINING WALL \ — \ 48"�G RAD I �kAN54IONAff \ -------- • 40LF A ,1� \ j /'/' / / / �.--`\\\ \ / \ F�EL ED TY- _r �' ' / / / \\ �°OO�°OO° BLOCK RETAINING WALL o \ 22 / \��� \ \ \ E E G�( P�) \� 8 LF �[�/8 LF /' / / {/ X ////// // • QUICK COUPLING VALVE \\_� �E•OI�ICRETE — ___ D-° _ --- - B ' \ �< /' ''/'' �I/ 4-- R-434422 — NSHFTIGTEJREbGE 415 // ///// //� ANCHOR AT EXISTING — RE-PL &A� €XISTI i-G - - _ �T / / / / \ \� /�/ / / / // // \ IN COMPLIANCE WITH CITY OF RENTON STANDARDS ----RtCRETECURB _BA LLQQ�JIIiQL1VE-TT�P1Cr ��/ ����— ____ ____ _ OVERFEINCJNG-W+T�-F / --- \ \ i� / DEVELOPMENT ENGINEERING ---------------- -1 - ---- Nu(T) - (TYP. o , MATCHLINE TO SHEET F111 / /'/ /� �// \ ------ --- / —_(NOTE PLAN VIEW ORIENTATION CHANGE) �j / /// HBray 06/24/2025 \-------------------�I _ � 7-7�� �ii�5- _----- 9r '---------------- _ - �' o ��; ti _�A- _ L��� NORTH CIVIL CONSTRUCTION PERMIT 2/21/25 SURVEYED: SCALE: VERTICAL: NAw DATE: 1988 • 21 F E B 2025 )f AS CIVIL CONSTRUCTION PERMIT 4 14 25 DESIGNED: 1 ++ =20 HORIZONTAL: NAD 1983/1991 O CITY OF LINDBERGH HIGH SCHOOL FIELDBOOK: z CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 EJG RENTONR FI L I MENT PAGE. K6/f-DA HOGAN DRAWN: E D MPROVE S LRB ONE INCH DATUM DRAWING NO: D.A. Hogan & Associates, inc. 00 FGISTER CHECKED: AT FULL SCALE Plonnin t F 1 1 0 1450 114th Ave. SE, Suite 225 sIo EPA'` EJG IF NOT ONE INCH g�Buildin g�Public Works Dept. BASEBALL LAYOUT PLAN NAL Bellevue, WA 98004 206-285-0400 N0. REVISION BY DATE APPR APPROVED:SCALESCALE ACCORDINGLY SHEET: OF: 22 42 O 0 N Q J L 0-