Loading...
HomeMy WebLinkAboutR-434436C'7 5 OPENING 4 CONCRETE PAD Nt FENCING WITH 1 12" CONCRETE CURB (NO LEAF) MEDIUM BROOM FINISH NETTING 0 EXPANSION 6 w 0.50' JOINT HOME PLATE (TYP) /z/ F240 4 8.00' 5' SINGLE F230 SWING GATE TOP OFFENCE 30.00' POSTS FOUNDATION 40.00' @ FG-1.5 (TYP.) 9' FENCING WITH 121 CONCRETE CURB/WALL 5 6 GAUGE FABRIC (3rd BASE SOFTBALL, 1st BASE BASEBALL) F240 1 F240 FINISH GRADE DUGOUT — PLAN VIEW NOT TO SCALE FABRIC 6" w U z w LL J J 0 Q (D 0 O ALL ALUMINUM PCTS PLAYER BENCH AND FITTING MFG: OUTDOOR ALUMINUM PCTS 21' OR EQUAL W/2" SQ.. GALV. TUBE CONC. SURFACE TO HAVE FINE BROOM FINISH BROOM FINISH TO BE IN DIRECTION OF RUN-OFF. STEEL TROWEL EDGES W/ 1/2" RADIUS. 18" ALLOW ONLY ENO SPACE FOR FO 1 S=1% a a W �/� - a d °4 d a 18" MIN. �L C, 9 d ° 5 CONCRETE 3< To F240 CURB/WALL ° d ° CONCRETE °d 12" FOOTING DIAM. 2 PLAYERS BENCH DETAIL F240 6x6x10/10 W.W.M 95% COMPACTED SUBGRADE CONCRETE FOOTING NOT TO SCALE PRE -PAINTED 24 GA HR36 METAL ROOF PANELS ON 20 GA. GALVANIZED/POWDER-COATED CORRUGATED METAL DECK. SECURE METAL DECK TO FENCE RAILS WITH EPDM WASHERED GALVANIZED TEK3 SCREWS AT 6" OC 12" TREATED 4x8 ROOF ---- SUPPORT (DF#2/HF#1) 9' FENCE, 6 GAUGE 12 1.5 PLAYERS 2 BENCH F240 CONCRETE PAD ""RIC -TOM RAIL METAL ROOF 4 EDGE F240 TREATED 4x8 ROOF SUPPORT (DF#2/HF#1) 10' CHAIN LINK t 1 - � FENCE F230 2" 6" 2" CLR CLR. #4 REBAR TIED TO EACH SLOPE SIDE OF FENCE POSTS ° d d ° 5 CONCRETE g o0700070007 0 F240 CURB/WALLo0000000000�o c d BASE AGGREGATE d COORDINATE LOCATION OF ° BENCH FOOTINGS TO NOT CONCRETE CURB CONFLICT WITH FENCE POST FOOTINGS d CONCRETE FOOTING CONCRETE FENCE ° (FOR FOOTING DEPTH FOOTING AND DIAMETER SEE ° ° FENCING SCHEDULE) :3: DUGOUT SECTION F240 NOT TO SCALE FINISH GRADE OF INFIELD TO BE FLUSH WITH DUGOUT SLAB AND CURBING INFILLED SYNTHETIC 6" TURF 1 F210 -#4 REBAR TREA- ROOF ELEVATION @ FRONT OF DUGOUT :4: DUGOUT ROOF EDGE F240 NOT TO SCALE #4 REBAR 9" O.C. - VERT./HORIZ. TIED TO EACH SIDE OF FENCE POSTS 5 F240 24 GAUGE ZINC-AUME FLASHING, PRE -FINISHED F.V. SET PANEL INTO SEALANT @FLASHING ROOF PANEL 3-3/8" F.V. r 20 GAUGE BARE GALVANIZED CLIP (3) PER PANEL 18 GAUGE BN-36 DECV ING PANEL 20 GAUGE BARE GALVANIZED FLAT STRAP TREATED 4x8 EPDM WASHERED GALVANIZED TEK3 SCREWS 6" O.C. 24 GAUGE ZINC-AUME FLASHING, PRE -FINISHED ROOF FRONT VIEW "COOL WALNUT" FENCE FABRIC DRIPLINE OF FLASHING AND ROOFLINE SHALL BE FLUSH WITH NCE FABRIC 3-3/8" F.V. UGE ZINC-AUME ,T, PRE -FINISHED FENCE POST CHAIN LINK 1 FENCE (TYP.) F230 20 GAUGE BARE GALVANIZED CLIP 24 GAUGE ZINC-ALUME FLASHING, PRE -FINISHED EDPM WASHERED GALVANIZED TEK3 SCREWS @ 24" O.C. INTO Z-FURRING 24 GAUGE ZINC-ALUME Z-FURRING, PRE FINISHED, INSTALLED BETWEEN PANEL RIBS 6111ROOF PANEL 20 GAUGE BARE GALVANIZED CLIP (3) PER PANEL 3" FENCE TOP RAIL ROOF SECTION ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦� ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ Oi♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i ♦♦♦♦♦♦��♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i ♦♦♦♦i♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ ♦♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i♦i� ♦♦♦♦�♦♦♦WWWWWWO ♦♦i♦i♦i♦i ♦i� �♦�♦�♦�♦�♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦ r Owl ♦!♦�!♦0M=*III♦s ♦i♦si♦si♦si♦si♦si♦si♦si♦si♦ ♦�♦ qUl I UNDERNEAIH CURB WALL DUGOUT RETAINING WALL SECTION NOT TO SCALE TIED TO EACH SIDE f OF FENCE POSTS NOTE ADDITIONAL POST LENGTH REQUIREMENTS FINISHED GRADE AT CONCRETE WALK / LANDSCAPE - 12" GALVANIZE METALT WOOD SELF -TAPPING SCREWS @ 6' O.C. 3/8" HARDBOARD @ EXPANSION JOINT CENTERLINE OF DUGOUT SLAB 2.5" 20 GAUGE BARE GALVANIZED CLIP I� (3) PER PANEL O 20 GAUGE BARE GALVANIZED OO FLAT STRAP Ln N U EPDM WASHERED GALVANIZED U TEK3 SCREWS 6" O.C. 1-1/2" F.V. 24 GAUGE ZINC-AUME FLASHING, PRE -FINISHED TI 3/16 BEAM ONE SIDE ONLY: SIMPSON BC40 BEAM BOTH SIDES: SIMPSON CCOQ44 ROOF ELEVATION @ INTERMEDIATE FENCE POSTS CONCRETE DUGOUT EXPANSION JOINT NOT TO SCALE CONCRETE PAD MEDIUM BROOM FINISH 2" (TYP.) 2.5" #4 REBAR CONTINUOUS EXCEPT AT EXPANSION JOINTS 20'0" O.C. R-434436 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING' J lIL HBray 06/24/2025 DATE: 9 AN CIVIL CONSTRUCTION PERMIT 2/21/25 SURVEYED: SCALE. VERTICAL: NAw 1988 CITY OF LINDBERGH HIGH SCHOOL 21 FEB 2025 HORIZONTAL: NAD 1983/1991 of as �o CIVIL CONSTRUCTION PERMIT RESUBMITTAL 4 14 25 DESIGNED: NTS FiELDB00K: CIVIL CONSTRUCTION PERMIT RESUBMITTAL 6/4/25 DRAWN: EJG RENTON FIELD IMPROVEMENTS Pam: D A H O G A N LRB ONE INCH DATUM DRAWING NO. D.A. Hogan & Associates, inc. �, eC/STER° tV CHECKED: AT FU o?LL SCALE Planning/Building/Public Works Dept. DUGOUT DETAILS F240 1450 114th Ave. SE, Suite 225 SIGNAL EEJG SCALE ACOT CORDINGLY Bellevue,Z Bellevue, WA 98004 206-285-0400 N0, REVISION BY DATE APPR APPROVED: SHEET: OF: 42 00 T O O O O N 0- Q J H H H L0 N Q J 0-