Loading...
HomeMy WebLinkAboutJ_Variance_Justification_Letter_250121_V1 3631 36th Ave W, Seattle WA 98199 • 206.321.1449 October 30, 2024 City of Renton Community and Economic Development Jill Ding, Senior Planner Matthew Herrera, Planning Director 1055 S Grady Way Renton, WA 98057 Re: 414 Monroe Ave NE Apartments Variance Justification Request Dear Jill, Matthew, Thank you for allowing me the opportunity to present the Variance Justification Request for our project at the subject address. The project is as follows: The Project: Demolish a 1 story industrial building and construct a 4 story mixed-use residential and commercial building with 20 apartment units and 2,250 square feet of street level commercial. Parking consists of 11 stalls within the structure and 13 stalls on an exterior surface parking area. The Site: A 15,625 sf lot located on the east side of Monroe Ave NE and zoned CA (Commercial Arterial). The project will dedicate 15’-5” along it’s frontage for street widening improvements resulting in a 14,562 sf lot. The site is surrounded on three sides by an apartment complex consisting of 3 story buildings and surface parking. Renton Municipal Code Requirements: According to 4-2-060 Zoning Use Table, attached dwelling-flats are allowed under condition P6 in the CA zone. Condition P6 does not specify that a stand-alone residential building would be permitted under the given zoning conditions, thus it is deduced that a vertically mixed-use building with ground floor commercial is required according to Ord. 6089, 12-12-2022. Chapter 4-4-150 of the Municipal Code stipulates that the commercial space at ground floor make up 40% of the building footprint in the CA zone. Additionally, the commercial space is to have an average depth of 30’ and no less that 20’ at any point and have a minimum floor to ceiling height of 18’. According to chapter 4-2-120A, the maximum density in the CA zone is 60 dwelling units per acre which calculates to 20 units based on lot size. Parking for residential units shall be enclosed within the same building as the unit it serves. According to chapter 4-4-080, parking is proposed at a rate 1 per dwelling unit and 2.5 per 1,000 sf of retail and 10 per 1,000 sf of restaurant dining area. A total of 26 parking stalls are proposed with 9 being shared between residential and commercial use. The site is located in District D according to the Urban Design Regulations on chapter 4- 3-100 which states the building should be oriented to the street with clear connections to 3631 36th Ave W, Seattle WA 98199 • 206.321.1449 the sidewalk. Regarding parking, surface parking lots shall not be located between the building and the front property line, garages at grade shall include screening or be enclosed from view with treatment such as walls, and the entire public facing facade shall be pedestrian oriented. Design Response: The proposed building seeks to introduce “infill” urban housing in a neighborhood that is suburban, automobile dependent in nature. The site is located near major local employers such as Boeing, PACCAR, numerous retailers along NE 4th St. and is immediately across Renton Technical College and is easily accessible by frequent bus transit along Monroe Ave NE and NE 4th street. It is anticipated that apartment tenants will be employed and frequent these businesses. Additionally, ground floor commercial spaces could serve the immediate area by providing casual eating and retail services for Renton Technical College and surrounding community. Retail spaces will be provided at a rate of 40% of the ground level building footprint. The 4-story building will consist of three levels for 20 apartment units and over 2,250 sf of street level retail/ restaurant space fronted by a pedestrian plaza with amenities such as seating, landscaping, weather protection and decorative paving. Commercial parking on a surface lot north of the retail spaces buffered from street view by screening and landscaping. Residential parking will be partially within the structure and behind the retail spaces and the remainder will be on an exterior surface lot behind the retail spaces blocked from street view. High quality perimeter fencing will block view from adjacent property. Variance in Conforming with the Renton Municipal Code In accordance to the Renton Municipal Use Code, the project proposes: •A 15-ground level front setback. •Ground floor commercial space depth of 20’ minimum and 30’ average, 18’ in height that occupies 40% of building footprint. •Twenty-four total parking stalls, 4 exterior commercial stalls, 9 exterior joint use stalls and 11 residential stalls within the structure. The project seeks a variance as follows: •The requirement that all residential parking stalls be within the structure. 3631 36th Ave W, Seattle WA 98199 • 206.321.1449 • If parking were to be within the building, the building footprint would increase, and the commercial space would be less than the 40% of building footprint requirement. Justification for Variance in Conforming with the Renton Municipal Code The proposed commercial space is maximized per the Municipal Code and will help to enhance the surrounding area by providing much needed retail services. Locating a portion of the residential parking on an exterior lot behind these commercial spaces will not impact the pedestrian street experience or the neighboring properties which are currently composed of low-rise multi-family residential structures and sprawling surface parking lots. The proposed exterior parking will be similar to adjacent properties and will not constitute a grant of special privilege. Conversely, enclosing all residential parking will be of no benefit as the location is not visible from the street or adjacent properties. As an alternative, we have explored locating the residential parking below grade. This option would require perimeter shoring and an upgrade to the building construction type. Similarly, locating the parking above grade would require ramping up 18’ to get above the retail level. This would result in an increase in bulk and scale as perceived by adjacent properties. While we recognize the intent of the code to maximize commercial space and minimize the visual impact of parking, these options are not possible given the limited size of the lot. The additional costs would pose a financial hardship that would be difficult to recover by 20 apartment units at the local rental rates. RMC 4-2-120C.16 Condtions: i. The perceived scale of the proposed structure that is created by the reduced setback is compatible with the abutting structures and the surrounding neighborhood; and; The site is currently surrounded by surface parking lots and is suburban in nature. This project seeks to create a pedestrian infill environment with a street edge defining building mass. Despite this goal and the request for a front setback reduction, the proposed building would be set back relative to the front of the closest building to the north along Monroe Ave NE. This is due to the 15’-6” deep dedication of properly along the front of the site which puts the 3631 36th Ave W, Seattle WA 98199 • 206.321.1449 proposed building 6’-6” further from the street compared to the existing building to the north which results in a reduction of perceived scale. ii. The required street frontage landscaping identified in RMC 4-4-070F1 is increased to fifteen feet (15') along all public street frontages with the exception of walkways, driveways, programmed pedestrian plazas, and the area of reduced setback; and: The proposed street level setback is 15’-0” to create a plaza with paved surfaces and built-in benches. The intent is to create a pedestrian environment and activate the retail experience by creating a usable outdoor space for restaurant seating and other ancillary activities. The plaza is protected by an overhead canopy constructed of heavy timber in order to create a softer, more tactile experience. iii. Enhanced landscaping, such as increased caliper size of trees, increased container size of shrubs, and/or increased quantity or diversity of plantings, is provided within the public right-of-way on the street frontage abutting the reduced setback; and: An 8’ wide planting strip is proposed along the street curb except at the driveway. The American Horbeams will be spaced at 30’ and will grow to be 30’ in height and 20’ in width along with a Rhododendron understory and Kinnikinnik ground cover. In our landscape architect’s opinion, this will provide a robust and diverse landscape to help transition from a vehicular to a protected pedestrian environment. iv. The project includes a public art installation, subject to review and approval, with a minimum monetary value of one percent (1%) of the assessed value of the proposed structure, or when the Administrator determines that it is impractical to install public art on site, payment of a fee-in-lieu may be approved in an amount of money approximating one percent (1%) of the assessed value of the proposed structure; and: No art is currently proposed. It is the intent to work with the city through Site Plan Review in order to include an art installation that is suitable for the neighborhood and the city. Additionally, the applicant is open to making a payment of a fee-in-lieu as determined by the city. v. The design of the proposed structure complies with all of the following requirements: 3631 36th Ave W, Seattle WA 98199 • 206.321.1449 (a) Back of house facilities such as walk-in freezers, bathrooms, breakrooms, storage rooms, or other rooms that do not contain windows, are not located along any building facade that fronts a public street; and: All these facilities are located at the back of the building and out of site from the street frontage. A required transformer room and doors is proposed at the south end of the frontage. (b) Floor to ceiling transparent windows are provided for at least fifty percent (50%) of the ground floor building facade that fronts a reduced setback; and: Ground level is 80% transparent. A required ground level transformer room makes up the rest. (c) The proposed structure includes design features such as step-backs of upper levels, changes in roof plane, and changes in roof form/slope in a manner that serves to reduce the apparent bulk of the proposed structure; and: Upper residential levels include 2 banks of 9’ wide and 4’ deep balconies to break up the façade. These recesses continue to up to form the roof parapets. (d) Canopies or similar design features are provided along any building facade that fronts a public street, with emphasis provided to the primary entry; and: Canopies 6’ deep are proposed along the entire frontage. The heavy- timber construction will create a softer more tactile feel as opposed to traditional steel canopies. A dramatic overhang will accentuate the primary entrance to the residential lobby. (e) Structured parking is not located along any building facade that fronts a reduced setback. Parking is located behind the retail spaces. No parking is proposed along the frontage of the building. 3631 36th Ave W, Seattle WA 98199 • 206.321.1449