HomeMy WebLinkAbout202140_005-010_5309-124_5309-125_Pre-Main_12 1 2011Customer Name
City of Renton, WA
Job Name
Sanitary Sewer
Rehabilitation
2011
Job No.
202140
Map #City
Renton, WA
Surveyed By (Operator)
Bravo Environmental
Location - Road Name
Sunset Blvd
Date
12/1/2011
Size (dia) x
8
Length
391
Shot-Seg Number
005-010
Start Manhole No.
5309-124
Finish Manhole No.
5309-125
Depth
0
Direction
Downstream
Media Number
02
Comments - General Material
Concrete
Job Type
Pre-Main
DOC ID: ITI/FRM-OPR-04 EFF.DATE: 12/01/03 APPROVAL: COMPANY MGT. REP.: ON-FILE
Dist. (ft.)Code Description Clock Remarks (Diameter, Intrusion, etc.)
0.0 MH Manhole 5309-124
2.0 SWM Surface damage, wear medium 8 to 4 Surface aggregate visible, Start continuous
defect 01
7.0 RF Roots, Fine 2 to 4
16.0 RF Roots, Fine 8 to 4
22.0 RF Roots, Fine 8 to 4
26.0 CN Connection 9 Abandoned, root ball lateral
37.0 RF Roots, Fine 8 to 4
81.0 CN Connection 10 Abandoned
109.0 CN Connection 10 Abandoned, root ball lateral
162.0 WL Water Level 20%
172.0 RF Roots, Fine 1 to 4
184.0 RF Roots, Fine 2 to 4
199.0 RF Roots, Fine 8 to 4
211.0 CC Circumferential Crack 8 to 4
213.0 CN Connection 10 Abandoned, root ball lateral
214.0 RF Roots, Fine 9 to 3
219.0 CN Connection 10 Abandoned
230.0 CN Connection 8 to 4
234.0 CNI Intruding Connection 9 Live
236.0 RF Roots, Fine 8 to 4
239.0 RF Roots, Fine 2 to 4
248.0 RF Roots, Fine 8 to 4
254.0 RF Roots, Fine 8 to 4
264.0 CN Connection 10 Abandoned, root ball lateral 100%
295.0 CN Connection 10 Abandoned, root ball lateral 100%
306.0 FC Circumferential Fracture 4 to 8
312.0 RF Roots, Fine 8 to 4
315.0 RF Roots, Fine 8 to 4
327.0 RF Roots, Fine 9 to 3
337.0 RF Roots, Fine 9 to 3
352.0 RF Roots, Fine 8 to 4
376.0 RF Roots, Fine 8 to 4
391.0 SWM Surface damage, wear medium 8 to 4 Surface aggregate visible, Finish
continuous defect 01
391.0 MH Manhole 5309-125
Page 1 of 1 Generated on 1/23/2012 at 3:35 PM by the PipeTech® TV inspection system.