Loading...
HomeMy WebLinkAboutMFP25003231.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP25003231 IVR Number: 25003231 Permit Information Permit Name: JB0002144832 OSP DE WAKGKV018 Address/Location:06/26/2025Application Date:2823059123Parcel Number: 12325 SE PETROVITSKY RD Permit Type:07/23/2025Issue Date:Franchise Permit Work Class:07/23/2026Expiration Date:Major Utility Job Number: JB0002144832Franchise Type:Cable Description: Comcast proposes to overlash 48ct fiber to existing strand; proof and pull thru existing conduit with 48ct fiber; place appropriate storage at existing riser; tie into new splice case; existing splice case, place new splice case; place new 24”x36” vault; replace/upgrade equipment at aerial and UG locations. Contacts Name Address PhoneTypeBilling Ashley Kiehn Mastec Communications 4610 Tacoma Avenue Sumner, WA 98390 ApplicantX Gayle Berner Mastec North America Inc. H: (000) 000-0000 C: (253) 364-9363 Applicant Rena Watts Comcast 1575 75th St SW, #200 Everett, WA 98203 B: (425) 977-9120 C: (425) 977-9120 Contact LOPEZ FLORES SALOME 12325 SE PETROVITSKY RD RENTON , WA 98058 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Gayle Berner 6/26/2025 Gayle Berner JB0002144832 OSP DE WAKGKV018 11868 SE PETROVITSKY RD, RENTON, WA 98028 7/26/2025 8/26/2025 9AM 330PM MASTEC NORTH AMERICA Gayle Berner 253-442-3574 4610 TACOMA AVE SUMNER, WA 98390 KRIS MCBRIDE 253-377-4687 Comcast proposes to overlash, proof and pull, place storage, splice cases, and vault. (See design for full description.) MFP25003231 9:00am 3:00pm Scott Warlick CED 7/17/2025 Monday Friday MFP25003231 MFP25003231 MFP25003231 MFP25003231 MFP25003231 MFP25003231 MFP25003231 MFP25003231 PROPOSED AERIAL AND UG FIBER INSTALLATIONEQUIPMENT REPLACEMENT AT AERIAL AND UG LOCATIONSPEDESTAL UPGRADECOMCAST2A DIGITAL (FDX) - WAKVD0AC00 1X2 - WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF11868 SE PETROVITSKY RD, RENTON, WA 98058, USAJB0002144832MFP25003231This permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HR RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF VICINITY MAPCONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-10SITE-PLAN11-12TYPICAL DETAILS12N/AN/AVICINITY MAP2PERMITTINGASHLEY KIEHN4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 999-2271EMAIL: ASKIEHN@SEFNCO.COMCOMCASTSEFNCO OPE11868 SE PETROVITSKY RD,RENTON, WA 98058CONSTRUCTION BEGIN12228 SE PETROVITSKY RD,RENTON, WA 98058CONSTRUCTION ENDS1JOSHUA ASHLEY11308 SW 68TH PKWYTIGARD, OR 97223PHONE: (503) 939-7931EMAIL: JOSHUA_ASHLEY@COMCAST.COMDOMINIC MINNITI4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 736-4697EMAIL: DMINNITI@SEFNCO.COMS2S3S4S5AAAAAAS6CUTOVER BEGIN12325 SE PETROVITSKY RD,RENTON, WA 98058CUTOVER END17604 134TH AVE SE,RENTON, WA 980582DESCRIPTION OF WORKTOTALOVERLASH 48CT FIBER TO EXISTING STRAND (6 POLES)1143LFPROOF/PULL THRU EXISTING CONDUIT WITH 48CT FIBER89LFPLACE APPROPRIATE STORAGE AT EXISTING RISER200LFTIE INTO NEW SPLICE CASE SP0517.WAKVEXISTING SPLICE CASE SP.WAKV.0003PLACE NEW SPLICE CASE SP0352.WAKVPLACE NEW 24"X36" VAULT (1)REPLACE EQUIPMENT AT AERIAL LOCATION (4)REPLACE EQUIPMENT UG AERIAL LOCATION (1)TOTAL:1432LFMFP25003231 RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12N/AN/AGENERAL NOTES3 THE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.RENTON1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET ALL CITY OF RENTON STANDARDS.2.ALL RENTON STANDARD DETAIL DRAWINGS CAN BE FOUND AT THE FOLLOWING WEBSITE:https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637033.ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 110.0-110.2.4.ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL- SECTION F 102.0.5.ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTONSTANDARD DETAIL - SECTION F 103.0.6.UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PHYSICALLYLOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALLINSTALLATIONS MUST COMPLY WITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.MFP25003231 RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12N/AN/ALEGEND 4LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERPOWERPARCEL LINERIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILSDSDWWSSSSGGTTLIPD/LEOPFOCRWRWBUILDING OUTLINEPFLFOG LINESIDEWALKSWSWTRENCHDIRECT BOREPROPOSED AERIAL STRAND PROOF/PULLPROPOSED OVERLASHMINOR ARTERIALCOLLECTOR ARTERIALINTERSTATE FREEWAYACCESS STREETPRINCIPAL ARTERIALBUILDINGR/WWARNING SIGN PLACEMENT (W/ PART #)TRAFFIC BARRELHYDRO-VAC TRENCHKEEPRIGHTREGULATORY SIGN (W/ PART #)LIMITSPEEDR2-125SPEED LIMIT CALLOUTSIGN PLACEMENT / DIRECTIONTRAFFIC CONEFLAGGER STATIONFLAGGER STATIONPATROL CARPOLICEOFFICERUNIFORMED POLICE OFFICERWORK VEHICLEFENCESTREET LIGHT HANDHOLETELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALSTREET LIGHT POLETRAFFIC SIGNAL HANDHOLECATV MANHOLECATV HANDHOLECATV PEDESTALTRAFFIC SIGNAL POLESTORM MANHOLEWATER VALVEWATER METERTELECOM PEDESTALSTORM INLETSTORM DRAIN UNKNOWN D?SISEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?STORM DRAIN VAULT SDSEWER CLEANOUTSEWER MANHOLESCSEWER CATCH BASIN SSSTORM ACCESS POINTBASE LAYERSEXISTING UTILITIESROAD HATCH CLASSIFICATIONROW WORK LINETYPECOMCAST UNDERGROUND SYMBOLSEXISTING UTILITY SYMBOLSTRAFFIC CONTROL SYMBOLSSTORM CATCH BASIN SDTRAFFIC SIGNAL VAULTGAS METERTEST VALVEPEDESTAL UNK UTILITYFIRE HYDRANTGAS VALVEGAS TEST POINTGAS MANHOLEWATER PUMPGGGWATER AIR CONTROL VALVEWATER WELLWATER SAMPLING STATIONPOWER HANDHOLEPOWER MANHOLEPOWER CABINETPOWER VAULTPOWER PEDESTALPPOWER UNKNOWN PPPPPP?SIGN POSTCULVERTTRANSIT STOPBUSSTOPDRIVEWAY (FOC OR EOP)SDSSANCHORSIDEWALK ANCHOR & GUY(P) FIBER & COUNTF48(P) .625 COAX(P) .875 COAXCOMCAST AERIAL SYMBOLSPROPOSEDEXISTINGWRECKOUTPOLE W/O RISERRISERARMVERTICAL GROUNDSLACK SPANOVERHEAD GUYTANGENT ATTACHMENTDEAD-ENDDOUBLE DEAD-END(E) FIBER & COUNTF48(E) .625 COAX(E) .875 COAXSLSLTSTSTSTSCCCTTTTTSTS?PUMPFWELLTREE TRIMLIGHT/MEDIUM/HEAVYLMH//WRECKOUTVAULTSPLICE CASEMANHOLEPEDESTALPPPAMINIBRIDGERTTTAATAPAMPLIFER POTHOLEBORE PIT / EXCAVATIONMMMPROPOSEDEXISTINGWRECKOUTNODEABCDSTORAGE LOOPX'X'LIT INTERSECTIONFASFLASHING ARROWSEQUENTIAL ARROWSEQUENTIAL CHEVRONFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONORFLASHING DIAMOND CAUTIONARROWBOARD PLACEMENT (SEE BELOW)CHANNELIZING DEVICES / MIN DIMENSIONSNOTE(S):1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE, LEGIBILITYDISTANCE, NUMBER OF ELEMENTS AND OTHERSPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OF ARROWHEADEQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVE SOLIDRECTANGULAR APPEARANCES. A TYPE D ARROW BOARDSHALL CONFORM TO THE SHAPE OF THE ARROW.ARROWBOARD TYPE MIN LEGIBILITYDISTANCEMIN SIZE MINIMUM# OFELEMENTSABCD48"×24"60"×30"96"×48"NONE12 MILE1 MILE34 MILE12 MILE121315125FT MIN4FT MIN8-12"45°TYPE 3 BARRICADE3FT MIN45°2FT MIN8-12"TYPE 1 BARRICADE3FT MIN8-12"2FT MIN45°TYPE 2 BARRICADE3-4"6"2"4"28'-36" MAXSPEED < 45MPHNIGHT AND/OR FREEWAYMORE THAN 36"4-6" TYPCONECONESPEED ≥ 45MPHDIRECTION INDICATOR BARRICADE12"8"36" MIN 24" MIN45°UNLIT INTERSECTIONDBTRENCHAVAC-TSPOTTER STATIONALL TRAFFIC CONTROL DEVICES / ANNOTATIONS PER MUTCDAMPLIFIER PICTURETAP PICTUREEquipmentMFP25003231 R/WR/WR/WR/WR/WR/WR/WR/WR/WFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WA AAAAAAAAAAAAAAAAAASE PETROVITSKY RDFOCFOCFOC FOCFOCFOCFOCSWSWSWSW SWFOCFOCFOCFOCFOCSWSWSWSWSWSWSW FOC120TH AVE SE118681742511822 11925SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWPOLE 2POLE 1EOP EOP EOP EOP EOP R/WR/WR/WR/W120TH LN SE (PRIVATE RD)11909SE PETROVITSKY RD181'254'RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12SITE PLAN - 1 5N12SITE PLAN CONSTRUCTION NOTESTIE IN TO EXISTING SPLICE CASESP0517.WAKV.13EXISTING POLES (1-2).OVERLASH 48CT FIBER TO EXISTINGSTRAND.4332MATCH TO SITE PLAN - 23 4EXISTING SPLICE CASESP.WAKV.0003.MFP25003231 R/WSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWR/WR/WR/WR/WR/WAAAAAAAAAAAAAAAAAAAAAAAAAAASE PETROVITSKY RDFOCFOCFOCFOCSWSWSWSWSWSWFOCFOCSWFOCSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSW1202917511121051211012107121151212112210POLE 3POLE 4POLE 5EOPEOPEOPEOPEOPEOPEOPEOPEOPSE 175TH LN (PRIVATE RD)SWFOCSWSWFOCR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W274'210'RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12SITE PLAN - 2 6NEXISTING POLES (3-5).12SITE PLAN CONSTRUCTION NOTES1OVERLASH 48CT FIBER TO EXISTINGSTRAND.212121MATCH TO SITE PLAN - 3SE PETROVITSKY RDMATCH TO SITE PLAN - 1 MFP25003231 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WAAAAAAASE PETROVITSKY RDFOCFOCSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCSWSWSWFOCSWFOCSWFOCFOCSWSWSWSWFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOC12228122171232512328POLE 6POLEEOPEOP 122ND PL SE (PRIVATE RD)89'R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W224'SE PETROVITSKY RDRDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12SITE PLAN - 3 7NPLACE NEW SPLICE SP0352.WAKV.12SITE PLAN CONSTRUCTION NOTESOVERLASH 48CT FIBER TOEXISTING STRAND.1EXISTING POLE (6).3RISER DOWN.4PROOF /PULL THRU EXISTINGCONDUIT WITH 48CT FIBER.542376PLACE APPROPRIATE STORAGELOOP AT EXISTING RISER.768REPLACE EQUIPMENT AT AERIALLOCATION.9MATCH TO SITE PLAN - 2 END OF ROW DESIGN.8599CONTINUE TO PRIVATE.MFP25003231 R/WR/WR/WR/WR/WR/WFOCFOCFOCFOCFOCSE PETROVITSKY RDSE PETROV ITSKY RDFOCFOCSWSWSWSWSWFOCSWSWFOCSWSWSWSWSWSWSWSWFOCFOCFOCSWSWSWR/WR/WR/WR/WR/WR/WSWSWSWFOCSW124191242012510POLE1242012520EOP EOP EOPEOPEOPEOP FOCFOCFOCSWSWSWSWR/WR/WR/WR/WR/WR/WR/WR/W 126TH AVE SE (PRIVATE RD)1250912517R/WR/WR/WR/WR/WR/WRDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12SITE PLAN - 4 8N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25003231 R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCR/W R/W FL FL FLR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WEOP EOPFOCFOC SE PETROVITSKY RDFOCSWSWSWFOCFOCFOCFOC1743412810128161282212727FL FL FLR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSWSWSWSWSWSWSWSWSWSWSWSWSW12828128TH AVE SESE 175 CTSWSWSW SW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCR/WR/WR/WR/WR/WR/WSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWPOLEPFOCFOC FOC FOC FOC FOC FOCR/WR/WR/W R/W R/W17415 17443128TH AVE SE RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12SITE PLAN - 5 9NREPLACE EXISTING CABINET WITHNEW NODE CABINET.1SITE PLAN CONSTRUCTION NOTES1742217430174191742317436128TH AVE SEPLACE NEW 24"X36" VAULT.24SE PETROVITSKY RDREPLACE EQUIPMENT AT AERIALLOCATION.3512345REPLACE EXISTING NODE WITHNEW 1X2 FDX NODE.REPLACE EQUIPMENT AT UGLOCATION.MFP25003231 SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWS W SWSWSWSWSWSW SW SW SWSWSWSWSWSWSWSWSWR/WR/WR/W17604SE PETROVITSKY RDSE PETROVITSKY RD134T H A V E S E 134TH AVE SE POLEFOCFOCFOCFOCFOCF O C FOCFOCFOCFOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOCSWSWSWSWSWSW SW SW SW SW SW R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12SITE PLAN - 6 10N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25003231 12REVISIONSDATEDESCRIPTIONINITIALRDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF NTS11TYPICAL DETAILS-1 AERIAL TYPICALSMFP25003231 12REVISIONSDATEDESCRIPTIONINITIALRDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF NTS12TYPICAL DETAILS-2 13"18"17"14"3"12"19"22"TYPICAL VAULT DETAILMFP25003231 ___________________________________________________________________________________ MasTec Network Solutions 4610 Tacoma Ave Sumner, WA 98390 ____________________________________________________________________________________________________________ MasTec Washington Locations Spokane ~ Puget Sound June 26, 2025 To whom it may concern: City of Renton 1055 South Grady Way Renton, WA 98057 RE: Aerial Variance Request for JB0002144832 To whom it may concern, Mastec North America has been contracted to design and engineer this project on behalf of Comcast Cablevision. Comcast is applying for a variance request in order to upgrade their existing facilities. Comcast proposes to overlash 48ct fiber to existing strand; proof and pull thru existing conduit with 48ct fiber; place appropriate storage at existing riser; tie into new splice case; existing splice case, place new splice case; ; place new 24”x36” vault; replace/upgrade equipment at aerial and UG locations. Comcast is requesting that the City of Renton approve this variance request based on the fact that the requirements for undergrounding this proposed over-lash will not cause substantial adverse impacts to other person or entities in the immediate area and will cause undue hardship. 1. Installation of undergrounding facilities will increase the total cost of construction roughly 15-25 times the amount of an aerial over-lash on the existing Comcast strand. 2. Potential damage to underground facilities will be increased. 3. Over-lash will not cause substantial adverse impact to other persons or entities in the immediate area. Over-lashing the cable will be accomplished in a few days, and the residents will not notice any impact. Comcast will clean up the over-lashed spans as necessary and identify and remove any existing dead cables along this route. 4. The variance is necessary to prevent and undue hardship due to the increased construction costs if forced to install the proposed extension underground. 5. The granting of the variance will not be materially detrimental to the public welfare because Comcast does agree to underground the cable system, but they are waiving the obligation into the future when all other utilities are underground to prevent an undue hardship against Comcast currently. Upon the granting of the Variance, Comcast will coordinate construction and traffic control as per your requirements. Comcast and their contractors want to cooperate at the highest level and agree to adhere to all provisions and requirements set forth by the City of Renton to insure safe installation and maintenance of the proposed facilities. ___________________________________________________________________________________ MasTec Network Solutions 4610 Tacoma Ave Sumner, WA 98390 ____________________________________________________________________________________________________________ MasTec Washington Locations Spokane ~ Puget Sound If you have any further questions regarding this project please contact Dominic Minniti at 253-736-4697. Thank you for your consideration in this matter. Ashley Kiehn Ashley Kiehn Director of Operations Support MasTec North America Cell (253)797-8118 | Ashley.Kiehn@mastec.com Attachments: 1. Application for ROW permit 2. 11” x 17” Site plan 3. 11” x 17” Design plan 4. Traffic Control Plan July 23, 2025 Ashley Kiehn Mastec North America 4610 Tacoma Avenue, Sumner WA 98390 Via Email: Ashley.Kiehn@mastec.com SUBJECT: Request for Undergrounding Exemption (JB#2144832, MFP25003231, 12325 SE Petrovitsky Rd) Dear Ms. Kiehn: The City of Renton has reviewed your request to grant Comcast an exemption from Renton Municipal Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required to be installed underground, pursuant to the standards of the section of RMC. Comcast proposes to have Mastec North America overlash new fiber for a total of approximately 1,143 lineal feet to existing Puget Sound Energy (PSE) poles along SE Petrovitsky Rd within the City. See the enclosed Site Plan showing the proposed overlashing limits. ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090. Ordinance 5720 grants Comcast, the right to install fiber optic cable and related appurtenances under, along, over, below, through and across the streets, avenues and alleys of City of Renton within the right-of-way of Renton. Section 3.4 of the franchise ordinance states that if all of the distribution lines all the wireline service providers, such as telecommunications service providers, as defined in RCW 35.99.010, a utility service provider or a Cable Operator (collectively “Service Providers”) in any portion of the Franchise Area are underground, Grantee shall place its Cable System’s distribution cables underground within that area; provided that such underground locations are actually capable of accommodating Grantee’s cable and other equipment without technical degradation of the Cable Systems’ signal quality. The proposal would utilize existing poles with other attached franchisee communication facilities and overlash to the existing Comcast aerial path. As minimum vertical height clearance of 15’-6” would need to be provided for, any existing obsolete cable will need to be removed; staff recommends these as conditions of approval. Therefore, the City is granting an exemption with conditions, per the Comcast franchise agreement which allows new overhead facilities to be placed overhead provided there are other similar providers overhead as well. Comcast is required to obtain all necessary private utility easements for work on private property. DECISION: The requested exemption from underground utility installation requirements RMC4-6-090 (C) as requested by the applicant is approved with conditions subject to the conditions below as the request complies with the Comcast Franchise Agreement. Comcast Job JB#2144832 Page 2 of 2 July 23, 2025 Conditions of Approval: 1. Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’-6”. 2. Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 3. A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed with the City Clerk, along with the required appeal fee, by 5:00 pm, August 7, 2025. Appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday.  The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date if your appeal is submitted electronically. The appeal submitted in person may be paid on the first floor in our Finance Department. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov.   Sincerely, Nathan Janders, PE, Development Engineering Manager On behalf of Brianne Bannwarth, PE, Development Engineering Director cc: Brianne Bannwarth, Development Engineering Director Justin Johnson, Construction Engineering Manager Scott Warlick, Engineering Specialist III Holly Powers, Engineering Specialist III Franchise Permits Enclosures: Site Plan Nathan Janders PROPOSED AERIAL AND UG FIBER INSTALLATIONEQUIPMENT REPLACEMENT AT AERIAL AND UG LOCATIONSPEDESTAL UPGRADECOMCAST2A DIGITAL (FDX) - WAKVD0AC00 1X2 - WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF11868 SE PETROVITSKY RD, RENTON, WA 98058, USAJB0002144832MFP25003231 RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF VICINITY MAPCONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5-10SITE-PLAN11-12TYPICAL DETAILS12N/AN/AVICINITY MAP2PERMITTINGASHLEY KIEHN4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 999-2271EMAIL: ASKIEHN@SEFNCO.COMCOMCASTSEFNCO OPE11868 SE PETROVITSKY RD,RENTON, WA 98058CONSTRUCTION BEGIN12228 SE PETROVITSKY RD,RENTON, WA 98058CONSTRUCTION ENDS1JOSHUA ASHLEY11308 SW 68TH PKWYTIGARD, OR 97223PHONE: (503) 939-7931EMAIL: JOSHUA_ASHLEY@COMCAST.COMDOMINIC MINNITI4610 TACOMA AVESUMNER, WA 98390PHONE: (253) 736-4697EMAIL: DMINNITI@SEFNCO.COMS2S3S4S5AAAAAAS6CUTOVER BEGIN12325 SE PETROVITSKY RD,RENTON, WA 98058CUTOVER END17604 134TH AVE SE,RENTON, WA 980582DESCRIPTION OF WORKTOTALOVERLASH 48CT FIBER TO EXISTING STRAND (6 POLES)1143LFPROOF/PULL THRU EXISTING CONDUIT WITH 48CT FIBER89LFPLACE APPROPRIATE STORAGE AT EXISTING RISER200LFTIE INTO NEW SPLICE CASE SP0517.WAKVEXISTING SPLICE CASE SP.WAKV.0003PLACE NEW SPLICE CASE SP0352.WAKVPLACE NEW 24"X36" VAULT (1)REPLACE EQUIPMENT AT AERIAL LOCATION (4)REPLACE EQUIPMENT UG AERIAL LOCATION (1)TOTAL:1432LFMFP25003231 RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12N/AN/AGENERAL NOTES3 THE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.RENTON1.ALL METHODS AND MATERIALS SPECIFICATION SHALL MEET ALL CITY OF RENTON STANDARDS.2.ALL RENTON STANDARD DETAIL DRAWINGS CAN BE FOUND AT THE FOLLOWING WEBSITE:https://edocs.rentonwa.gov/Documents/Browse.aspx?startid=13637033.ALL ASPHALT REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL -SECTION F 110.0-110.2.4.ALL SIDEWALK REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTON STANDARD DETAIL- SECTION F 102.0.5.ALL CURB AND GUTTER REPAIR TO BE DONE IN ACCORDANCE WITH RENTON STANDARDS. SEE RENTONSTANDARD DETAIL - SECTION F 103.0.6.UTILITY LOCATIONS SHOWN ON THIS PLAN ARE BASED ON DOCUMENT RESEARCH AND FIELD EVALUATION. THEINFORMATION MAY NOT BE ACCURATE OR COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PHYSICALLYLOCATE AND VERIFY LOCATION AND DEPTH OF ALL UTILITIES WITHIN THE CONSTRUCTION PATH. ALLINSTALLATIONS MUST COMPLY WITH MINIMUM HORIZONTAL AND VERTICAL CLEARANCES FROM UTILITIES.MFP25003231 RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12N/AN/ALEGEND 4LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERPOWERPARCEL LINERIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILSDSDWWSSSSGGTTLIPD/LEOPFOCRWRWBUILDING OUTLINEPFLFOG LINESIDEWALKSWSWTRENCHDIRECT BOREPROPOSED AERIAL STRAND PROOF/PULLPROPOSED OVERLASHMINOR ARTERIALCOLLECTOR ARTERIALINTERSTATE FREEWAYACCESS STREETPRINCIPAL ARTERIALBUILDINGR/WWARNING SIGN PLACEMENT (W/ PART #)TRAFFIC BARRELHYDRO-VAC TRENCHKEEPRIGHTREGULATORY SIGN (W/ PART #)LIMITSPEEDR2-125SPEED LIMIT CALLOUTSIGN PLACEMENT / DIRECTIONTRAFFIC CONEFLAGGER STATIONFLAGGER STATIONPATROL CARPOLICEOFFICERUNIFORMED POLICE OFFICERWORK VEHICLEFENCESTREET LIGHT HANDHOLETELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALSTREET LIGHT POLETRAFFIC SIGNAL HANDHOLECATV MANHOLECATV HANDHOLECATV PEDESTALTRAFFIC SIGNAL POLESTORM MANHOLEWATER VALVEWATER METERTELECOM PEDESTALSTORM INLETSTORM DRAIN UNKNOWN D?SISEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?STORM DRAIN VAULT SDSEWER CLEANOUTSEWER MANHOLESCSEWER CATCH BASIN SSSTORM ACCESS POINTBASE LAYERSEXISTING UTILITIESROAD HATCH CLASSIFICATIONROW WORK LINETYPECOMCAST UNDERGROUND SYMBOLSEXISTING UTILITY SYMBOLSTRAFFIC CONTROL SYMBOLSSTORM CATCH BASIN SDTRAFFIC SIGNAL VAULTGAS METERTEST VALVEPEDESTAL UNK UTILITYFIRE HYDRANTGAS VALVEGAS TEST POINTGAS MANHOLEWATER PUMPGGGWATER AIR CONTROL VALVEWATER WELLWATER SAMPLING STATIONPOWER HANDHOLEPOWER MANHOLEPOWER CABINETPOWER VAULTPOWER PEDESTALPPOWER UNKNOWN PPPPPP?SIGN POSTCULVERTTRANSIT STOPBUSSTOPDRIVEWAY (FOC OR EOP)SDSSANCHORSIDEWALK ANCHOR & GUY(P) FIBER & COUNTF48(P) .625 COAX(P) .875 COAXCOMCAST AERIAL SYMBOLSPROPOSEDEXISTINGWRECKOUTPOLE W/O RISERRISERARMVERTICAL GROUNDSLACK SPANOVERHEAD GUYTANGENT ATTACHMENTDEAD-ENDDOUBLE DEAD-END(E) FIBER & COUNTF48(E) .625 COAX(E) .875 COAXSLSLTSTSTSTSCCCTTTTTSTS?PUMPFWELLTREE TRIMLIGHT/MEDIUM/HEAVYLMH//WRECKOUTVAULTSPLICE CASEMANHOLEPEDESTALPPPAMINIBRIDGERTTTAATAPAMPLIFER POTHOLEBORE PIT / EXCAVATIONMMMPROPOSEDEXISTINGWRECKOUTNODEABCDSTORAGE LOOPX'X'LIT INTERSECTIONFASFLASHING ARROWSEQUENTIAL ARROWSEQUENTIAL CHEVRONFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONORFLASHING DIAMOND CAUTIONARROWBOARD PLACEMENT (SEE BELOW)CHANNELIZING DEVICES / MIN DIMENSIONSNOTE(S):1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE, LEGIBILITYDISTANCE, NUMBER OF ELEMENTS AND OTHERSPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OF ARROWHEADEQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVE SOLIDRECTANGULAR APPEARANCES. A TYPE D ARROW BOARDSHALL CONFORM TO THE SHAPE OF THE ARROW.ARROWBOARD TYPE MIN LEGIBILITYDISTANCEMIN SIZE MINIMUM# OFELEMENTSABCD48"×24"60"×30"96"×48"NONE12 MILE1 MILE34 MILE12 MILE121315125FT MIN4FT MIN8-12"45°TYPE 3 BARRICADE3FT MIN45°2FT MIN8-12"TYPE 1 BARRICADE3FT MIN8-12"2FT MIN45°TYPE 2 BARRICADE3-4"6"2"4"28'-36" MAXSPEED < 45MPHNIGHT AND/OR FREEWAYMORE THAN 36"4-6" TYPCONECONESPEED ≥ 45MPHDIRECTION INDICATOR BARRICADE12"8"36" MIN 24" MIN45°UNLIT INTERSECTIONDBTRENCHAVAC-TSPOTTER STATIONALL TRAFFIC CONTROL DEVICES / ANNOTATIONS PER MUTCDAMPLIFIER PICTURETAP PICTUREEquipmentMFP25003231 R/WR/WR/WR/WR/WR/WR/WR/WR/WFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSWSWSWSWSWR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/WA AAAAAAAAAAAAAAAAAASE PETROVITSKY RDFOCFOCFOC FOCFOCFOCFOCSWSWSWSW SWFOCFOCFOCFOCFOCSWSWSWSWSWSWSW FOC120TH AVE SE118681742511822 11925SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWPOLE 2POLE 1EOP EOP EOP EOP EOP R/WR/WR/WR/W120TH LN SE (PRIVATE RD)11909SE PETROVITSKY RD181'254'RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12SITE PLAN - 1 5N12SITE PLAN CONSTRUCTION NOTESTIE IN TO EXISTING SPLICE CASESP0517.WAKV.13EXISTING POLES (1-2).OVERLASH 48CT FIBER TO EXISTINGSTRAND.4332MATCH TO SITE PLAN - 23 4EXISTING SPLICE CASESP.WAKV.0003.MFP25003231 R/WSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWR/WR/WR/WR/WR/WAAAAAAAAAAAAAAAAAAAAAAAAAAASE PETROVITSKY RDFOCFOCFOCFOCSWSWSWSWSWSWFOCFOCSWFOCSWFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOCSWSW1202917511121051211012107121151212112210POLE 3POLE 4POLE 5EOPEOPEOPEOPEOPEOPEOPEOPEOPSE 175TH LN (PRIVATE RD)SWFOCSWSWFOCR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W274'210'RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12SITE PLAN - 2 6NEXISTING POLES (3-5).12SITE PLAN CONSTRUCTION NOTES1OVERLASH 48CT FIBER TO EXISTINGSTRAND.212121MATCH TO SITE PLAN - 3SE PETROVITSKY RDMATCH TO SITE PLAN - 1 MFP25003231 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WAAAAAAASE PETROVITSKY RDFOCFOCSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCSWSWSWFOCSWFOCSWFOCFOCSWSWSWSWFOCFOCFOCFOCSWSWSWSWSWSWSWSWSWSWFOCFOCFOCFOCFOC12228122171232512328POLE 6POLEEOPEOP 122ND PL SE (PRIVATE RD)89'R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W224'SE PETROVITSKY RDRDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12SITE PLAN - 3 7NPLACE NEW SPLICE SP0352.WAKV.12SITE PLAN CONSTRUCTION NOTESOVERLASH 48CT FIBER TOEXISTING STRAND.1EXISTING POLE (6).3RISER DOWN.4PROOF /PULL THRU EXISTINGCONDUIT WITH 48CT FIBER.542376PLACE APPROPRIATE STORAGELOOP AT EXISTING RISER.768REPLACE EQUIPMENT AT AERIALLOCATION.9MATCH TO SITE PLAN - 2 END OF ROW DESIGN.8599CONTINUE TO PRIVATE.MFP25003231 R/WR/WR/WR/WR/WR/WFOCFOCFOCFOCFOCSE PETROVITSKY RDSE PETROV ITSKY RDFOCFOCSWSWSWSWSWFOCSWSWFOCSWSWSWSWSWSWSWSWFOCFOCFOCSWSWSWR/WR/WR/WR/WR/WR/WSWSWSWFOCSW124191242012510POLE1242012520EOP EOP EOPEOPEOPEOP FOCFOCFOCSWSWSWSWR/WR/WR/WR/WR/WR/WR/WR/W 126TH AVE SE (PRIVATE RD)1250912517R/WR/WR/WR/WR/WR/WRDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12SITE PLAN - 4 8N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25003231 R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WFOCFOCFOCFOCFOCFOCFOC FOCFOCFOCR/W R/W FL FL FLR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WEOP EOPFOCFOC SE PETROVITSKY RDFOCSWSWSWFOCFOCFOCFOC1743412810128161282212727FL FL FLR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSWSWSWSWSWSWSWSWSWSWSWSWSW12828128TH AVE SESE 175 CTSWSWSW SW FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCR/WR/WR/WR/WR/WR/WSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWPOLEPFOCFOC FOC FOC FOC FOC FOCR/WR/WR/W R/W R/W17415 17443128TH AVE SE RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12SITE PLAN - 5 9NREPLACE EXISTING CABINET WITHNEW NODE CABINET.1SITE PLAN CONSTRUCTION NOTES1742217430174191742317436128TH AVE SEPLACE NEW 24"X36" VAULT.24SE PETROVITSKY RDREPLACE EQUIPMENT AT AERIALLOCATION.3512345REPLACE EXISTING NODE WITHNEW 1X2 FDX NODE.REPLACE EQUIPMENT AT UGLOCATION.MFP25003231 SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWS W SWSWSWSWSWSW SW SW SWSWSWSWSWSWSWSWSWR/WR/WR/W17604SE PETROVITSKY RDSE PETROVITSKY RD134T H A V E S E 134TH AVE SE POLEFOCFOCFOCFOCFOCF O C FOCFOCFOCFOC FOC FOC FOCFOCFOCFOCFOCFOCFOCFOCFOCFOCFOC FOC FOC FOC FOCFOCFOCFOCFOCSWSWSWSWSWSW SW SW SW SW SW R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W RDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF 12SITE PLAN - 6 10N1SITE PLAN CONSTRUCTION NOTESREPLACE EQUIPMENT AT AERIALLOCATION1MFP25003231 12REVISIONSDATEDESCRIPTIONINITIALRDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF NTS11TYPICAL DETAILS-1 AERIAL TYPICALSMFP25003231 12REVISIONSDATEDESCRIPTIONINITIALRDIGALERT2A DIGITAL (FDX) - WAKVD0AC00 1X2 - 11868 SE PETROVITSKY RD RENTON, WA 98058, USA JB0002144832REVISIONSDATEDESCRIPTIONINITIAL COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:MADHU06/23/2025WAKVD0AB00 1X2 (WAKGKV018 3X3) - RF NTS12TYPICAL DETAILS-2 13"18"17"14"3"12"19"22"TYPICAL VAULT DETAILMFP25003231 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Conditions for Permit MFP25003231 Engineering 1 A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 2 Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15'-6". 3 Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 4 The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. Page 1 of 1