Loading...
HomeMy WebLinkAboutMFP25003490.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP25003490 IVR Number: 25003490 Permit Information Permit Name: Puget Sound Energy - Electric 101188468- World Cup Legacy SquareAddress/Location:07/09/2025Application Date:7841800195Parcel Number: 510 S 3RD ST Permit Type:07/23/2025Issue Date:Franchise Permit Work Class:07/23/2026Expiration Date:Minor Utility Job Number: 101188468Franchise Type:Electric Description: Puget Sound Energy Electric At hand hole 317811 165999, crew to replace B/O egg shell secondary connectors with new #10 350 secondary 66 position connector bars. Crew will connect customer owned, installed, and maintained 1 run of #2 cable. No HS disturbance anticipated. Contacts Name Address PhoneTypeBilling Katie Zimmerman Puget Sound Energy 1660 Park Lane Burlington, WA 98233 B: (425) 620-6742 C: (425) 620-6742 ApplicantX Permits Central 355 110th Ave NE Bellevue, WA 98004 B: (425) 620-6742 H: (425) 620-6742 C: (425) 620-6742 Contact Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08 Bellevue, WA 98009 B: (888) 225-5773Emergency Contact CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Katie Zimmerman Puget Sound Energy 1660 Park Lane Burlington, WA 98233 B: (425) 620-6742 C: (425) 620-6742 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. PUBLIC WORKS DEPARTMENT Page 1 of 6 | Published: 2/25/2025 Transportation Systems Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 2/25/2025 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK AND FOR TRAFFIC SIGNAL WORK WITHIN 150 FEET OF THE INTERSECTION AT LEAST FIFTEEN (15) WORKING DAYS BEFORE THE DATE OF WORK. FOR PURPOSES OF THIS APPLICATION, WORKING DAYS ARE DEFINED AS MONDAY THRU FRIDAY, AND EXCLUDING CITY HOLIDAYS. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a Traffic Control Plan (TCP) and obtain City's approval of that plan when construction, repair, or maintenance work is to be conducted within the City's right-of-way. 1.Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2.All TCPs must conform to all attached requirements. Failure to do so may be subject to resubmittal. 3.Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” 4.Resubmittal may be required for TCPs that are incomplete and do not display proper requirements as described in the guidelines. Additional review time may be needed. By signing, I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge and have read all the requirements and guidelines on this application. Applicant’s Signature Date Applicant’s Name (Print) Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: ___________ Description of Work: 24 Hour Emergency Contact Name & Phone: Approval By: ______________________________________________ Date:____________________ PW/Transportation or CED/Development Engineering Division Potelco, Inc 6905 S 228th St Kent, WA 98466 Please See Attached Katie Zimmerman 7/9/2025 101188468- World Cup Legacy Square 510 S 3rd St Jenny Chau (253) 208-9480 MFP25003490 Monday Friday Scott Warlick CED 7/23/2025 9:00am 2:00pm Page 2 of 6 | Published: 2/25/2025 This Page Intentionally Left Blank Page 3 of 6 | Published: 2/25/2025 APPLICANT AGREES TO ALL THE FOLLOWING REQUIREMENTS: GENERAL •Applicant is responsible for compliance with all traffic regulations of the City of Renton (City) and the State of Washington, including codes and regulations not described in this application. •Work Zone Traffic Control shall be in accordance with Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to Washington State Department of Transportation (WSDOT) traffic control plans. •Any lane or street closures not in conformance with the approved Traffic Control Plan (TCP) and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. •Indemnify and hold harmless the City from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved TCPs including claims arising from towing of private vehicles and the acts of Applicant’s agents and employees. •Applicant must comply with all conditions of the application. •The City shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. •In the event any claim or suit is brought against City within the scope of this application, Applicant is responsible to pay for legal counsel chosen by the City to defend against same. •No more than one TCP shall be in use at any given time for a single project. If multiple TCPs are submitted for review and approval at the same time, the TCPs shall be clearly labeled as separate plans and include construction phasing and sequencing. •Previously approved TCPs cannot be combined into a new TCP without review and approval by the City. •Expired TCP is not valid and shall not be used. Applicant shall resubmit the expired TCP for approval with the updated date and time and/or any changes to TCP. •Applicant must have the approved TCP prior to commencing the work. •Approved TCP must be at the work site during work hours. •Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. •Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. •At signalized intersections, vehicle detection shall always remain operational, unless approved in this TCP and notified Transportation Signal Maintenance prior to commencing work. If damage occurs to existing vehicle detection that is to remain, it is Applicant’s responsibility to replace with video vehicle detection equipment that meets current City’s standards at Applicant’s expense. •When not in use, temporary traffic control devices shall be removed or covered immediately. It is the Applicant’s responsible to cover any temporary traffic control devices when not applicable for the construction activities. Similarly, when work is suspended for short periods of time, traffic control devices that are no longer necessary shall be removed or covered. If deemed abandoned, City crews will remove and may store them at the City’s maintenance shop (3555 NE 2nd Street) for up to sixty (60) days. The City is not responsible for any private property from City assets and identifying the property owner. •Applicant is responsible to maintain existing pedestrian accessible routes during work and non-work hours. At intersections, the work on pedestrian facilities shall be limited to one (1) corner at a time, with the least possible inconvenience or delay to pedestrians. Pedestrian pushbuttons shall remain accessible at all times, unless approved pedestrian accessible detour(s) are provided. Accessibility to existing or temporary Page 4 of 6 | Published: 2/25/2025 pedestrian pushbuttons shall not be impaired. Deficiencies caused by Applicant’s operations shall be repaired at Applicant’s expense. •Applicant shall provide complete assistance and accommodation from a dedicated pedestrian escort to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. •Driveway and alley access shall be maintained at all times, also see RMC Chapters 9 and 10 for Street Closure and Street Excavation for details. Applicant is responsible for coordinating with the property owners and/or residents prior to commencement of the work. •Pavement excavation shall be limited to a maximum of one travel lane at a time unless otherwise approved. •Accessibility for emergency vehicles shall be maintained at all times. PUBLIC OUTREACH •Applicant must notify Transportation Signal Maintenance (425-430-7423) and City inspector (425-430- 7203) at least twenty-four (24) hours before commencing work (lane shift/closure or near a signal) affecting the vehicle detection. •Applicant shall notify emergency services (253-852-2121) twenty-four (24) hours before any street closures or lane closures. •Applicant shall call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five (5) working days (excluding weekends and holidays) prior to starting any work. •Applicant shall coordinate with King County Metro Transit Construction Information Center (206-477-1140 or construction.coord@kingcounty.gov) for any construction or installation activities affecting transit operations or facilities. Notification information and guidelines can be found at: https://kingcounty.gov/en/dept/metro/about/contractor-resources/transit-system-impacts. WORKING DAYS AND TIMES •Normal working days are Monday through Friday. Work on holidays, weekends or at night shall not occur without City’s approval. For work times between 10:00 p.m. and 7:00 a.m., see Night Work section below for details. •Work time begins when any street or travel lane is fully or partially closed. This includes set up and removal within the traveled way. •If the City determines the closure hours adversely affect traffic during the work, the City may require to adjust or reduce the working hours accordingly. Reduced work hours may be required by the City to minimize traffic impacts for any work located near a school during pick-up and drop-off times or on an arterial street. (See WSDOT Functional Classification Map: https://www.wsdot.wa.gov/data/tools/geoportal/?config=FunctionalClass) •Applicant may request the City for consideration of extended or modified working hours. Such request must be approved by the City before changing hours of work. CLOSURES •All closure hours and days are subject to local permit and ordinance conditions (such as noise ordinances). More information can be found on https://www.rentonwa.gov/City-Services/Permit-Center. Total street closure lasting more than twenty-four (24) hours is subject to City Council authorization per Section 9-9 of the Renton Municipal Code (RMC). •Road closure notice – Applicant must install Portable Changeable Message Sign (PCMS) boards no less than five (5) working days in advance of effective date and time, not including holidays, at location(s) as identified in the TCP. Other methods of displaying the messages shall be approved by the City. Page 5 of 6 | Published: 2/25/2025 •Road closure notice messages must include at least the following: ROAD WILL BE CLOSED MONTH/DAY – MONTH/DAY _AM - _PM •Road and/or sidewalk closure must be evaluated by the City with respect to both the necessity as well as the impact of the closure to the public. Applicant shall submit detour plans for road closures to accommodate both motorized and non-motorized users, including accessible pedestrian route(s). Road closures shall require additional temporary traffic control including advance notification, approach and detour signage. •Applicant is responsible to temporarily remove the flags and install bags over the flag holders for any work requiring the temporary closure of a crosswalk equipped with pedestrian flags. Applicant shall ensure the bags remain intact and shall replace damaged bags as needed or determined necessary by the City of Renton inspector. For any misplaced or lost flags, Applicant is responsible to replace at Applicant’s own expense. Upon restoration of the crosswalk, Applicant shall remove the bags and return all flags to the holders. Inventory of pedestrian flags must be submitted to the City inspector and reported to City of Renton Transportation Signal Maintenance (425-430-7423) prior to removal. UNIFORMED POLICE OFFICERS (UPO) / FLAGGERS •Any construction activities within one hundred and fifty (150) feet of a signalized intersection shall require Uniformed Police Officer(s) (UPO) at the traffic signal, unless otherwise approved in this TCP and evaluated by City Transportation for the impacts of traffic signal operations and safety. •Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. •For TCPs that require the presence of UPO to manage vehicular traffic and pedestrians at signalized intersections, Applicant shall coordinate with Transportation Signal Maintenance (425-430-7423) at least twenty-four (24) hours in advance for any signal that will be placed in red flashing mode. Applicant shall notify Transportation Signal Maintenance when the intersection is back to the normal traffic signal operations. TEMPORARY TRAFFIC SIGNALS OR TRAFFIC SIGNAL MODIFICATION •Temporary traffic signal programming or modification requires a minimum fifteen (15) working days for each traffic signal controller to be programmed and tested by City Transportation staff before starting the work. The Start Date on this TCP shall reflect the time for temporary traffic signal programming or modification. TEMPORARY NO-PARKING •Applicant must post notice of date(s) and time(s) of Temporary No Parking Zone with signs at every hundred (100) feet at least seventy-two (72) hours in advance of effective date and time. •Applicant is responsible to show on the TCP the limits of Temporary No Parking Zone, identifying barricade locations for vacate parking or curb lane usage. The cover sheet of this approved TCP form must be attached to each Temporary No Parking Sign on the project site. •Two travel lanes (one for each approach) must be open at all times on arterial streets unless approved in this TCP. NIGHT WORK •Between the hours of 10 p.m. and 7 a.m., approved Noise Variance shall be required (See Section RMC 8-7- 8)for night work. Process may take up to twelve (12) weeks. More information can be found at https://www.rentonwa.gov/City-Services/Permit-Center/Land-Use-Development/Noise-Variance. •City may require night work for TCPs that have severe traffic impacts on arterial streets. Page 6 of 6 | Published: 2/25/2025 •Night work shall always be required if two lanes of traffic (One for each approach) cannot be maintained on an arterial street. •Night work shall be required if an evaluation of existing traffic volumes and patterns finds that any TCP will functionally reduce an arterial or high-volume collector street to only one lane of traffic. •The following configurations may require night work: Work at traffic signals that requires shifting one direction of traffic into a left turn pocket where a high volume of left turns occur. Work at traffic signals that requires shifting two directions of traffic into left turn pockets. Work at traffic signals that requires shifting high-volume left-turn movement into a through lane on a single approach to the intersection. Work at signals that requires shifting left-turning traffic into a through lane on multiple approaches to the intersection. •If City’s initial TCP review finds that night work is required, a pre-construction meeting is mandatory to confirm the extents of the work required, the duration of work, anticipated noise levels, and any potential alternatives to mitigate the impact of night work to adjacent residents prior to review and approval of the TCP. TRAFFIC CONTROL PLAN (TCP) FORMAT •TCP must be site and project specific. The TCP shall clearly indicate all existing transportation facilities impacted by work including roads, bike lanes, sidewalks, transit stops, and driveways. Typical drawings, taper tables and MUTCD illustrations, by themselves, are insufficient. •Each construction phase shall be provided with appropriate work zone traffic control. The impacts of utility relocation, traffic delays, detours and capacity restrictions must be considered and addressed. A suitable sequence of construction activities must be discussed with City Staff prior to fully developing TCPs based on the complexity of a project. •TCPs shall be clearly labeled as separate plans to identify the construction sequencing during each phase when more than one TCP layout is submitted. •TCP must be submitted with an electronic copy of TCP layout(s), on 11” X 17” paper size PDF format, which consist of: Map(s) showing the location of the project and work area. All fonts shall be legible and a minimum 10-point font size. All symbols of viewing or printing shall be clear and contrasting. All streets shall be labeled, and layout must include a north arrow and scale. Must show channelizing devices, signing, flagger locations, barricades, PCMS boards, etc. Show locations where the standard traffic control plans are applied. ONE WAY RENTON TC ACRDBUSONLYBUSONLY1919 S 3RD ST SMITHERS AVE SLOGAN AVE SislandHH1 R11-2STREETCLOSEDW20-1ROAD WORK AHEAD BEPREPARED TOSTOP W3-4X'≥X'≥X'≥W20-7A15 15 W20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7A1313131310POLICEUPO STOPW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4 X'≥X'≥X'≥ W20-7A PLACE SIGN ON BOTH SIDES CROSS HERES/W CLOSEDR9-11A S/WCLOSEDR9-9CROSS HERES/W CLOSEDAHEADR9-11C/WCLOSEDR9-3N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Kali-Jamal Collins 424-425-6425 Kali-jamal.collins@pse.com 1 OF 2510 3rd St, Renton, WA 1 500401538 07/02/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRONARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP UG/BOX/VAULTVAULT TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Jamal I. Collins Card No. 013375Card Exp. 10/2026Kali-Jamal.Collins@pse.com(425)424-6425 MFP25003490 ONE WAY RENTON TC ACRDBUSONLYBUSONLY1919 S 3RD ST SMITHERS AVE SLOGAN AVE SislandR11-2STREETCLOSEDW20-1ROAD WORK AHEAD BEPREPARED TOSTOP W3-4X'≥X'≥X'≥W20-7A15 15 W20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7A1313131310POLICEUPO STOPW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4 X'≥X'≥X'≥ W20-7A PLACE SIGN ON BOTH SIDES S/W CLOSED R9-9CROSS HERES/W CLOSEDAHEADR9-11V01CROSS HERE S/W CLOSEDAHEAD R9-11S/WCLOSEDR9-9Project Address: Page PSE PUGETSOUNDENERGY Designer: Job # REV Kali-Jamal Collins 424-425-6425 Kali-jamal.collins@pse.com 2 OF 2510 3rd St, Renton, WA 1 500401538 07/02/2025 Notes: 1. All signs and spacing to conform to the MUTCD and City of Renton standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated, if indicated use ADA compliant channelization. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place during approved work hours as per jurisdictional requirements. (Generally between 9 a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3 p.m. on arterials. If night time work is approved, signaling and flaggers shall conform to WAC 296-155-305. Night time work to take place between _____________and ______________.) 8. All Flagger and Downstream tapers shall be 50'-100'. MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 10 11 12 20 70 75 80 25 105 115 125 30 150 165 180 35 205 225 245 40 270 295 320 45 475 495 540 POSTED SPEED (MPH) 50 500 550 600 55 550 605 660 60 - 660 720 65 - - 780 70 - - 840 LEGEND 28" TRAFFIC CONE SIGN LOCATION TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS RIGHT OF WAY WORK AREA CHEVRONARROW BOARD FLAGGER UNIFORMED POLICE OFFICERPOLICE STOP UG/BOX/VAULTVAULT TEMPORARY TRAFFIC CONTROL PLAN Puget Sound Energy Traffic Control Supervisor: Jamal I. Collins Card No. 013375Card Exp. 10/2026Kali-Jamal.Collins@pse.com(425)424-6425 N SIGN SPACING MPH 60/65 45/55 35/40 30 25 "X" 1000' 500' 350' 200' 100' CHANNELIZATION DEVICE SPACING MPH 55/70 35/45 25/30 TAPER 40 30 20 TANGENT 80 60 40 MFP25003490 CONFIRMING WORKSKETCH POLE CL. POLE HT. CABLE # YEARTYPE CABLE #YEAR TYPE CABLE #YEAR TYPE Additional Work Order Code Numbers: MID: "Locates Required"Yes No"Outages Required"Yes No "Flagging Required"Yes No CALL (800) 424-55552 BUSINESS DAYS BEFORE YOU DIG THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES 5 REAL ESTATE/EASEMENT PERMIT 4 3 FUNCTION NAME PHONE NO DATE 2 PROJECT MGR JENNY CHAU 1 ENGR - POWER REV #DATE BY DESCRIPTION ENGR - GAS COUNTY Emer Sect Gas Wk Ctr POWER WK CTR DRAWN BY N/A CHECKED BY 1/4 SEC OP MAP PLAT MAP APPROVED BY JENNY CHAU FOREMAN #1 U-MAP NO (POWER)OH Ckt Map UG Ckt Map CIRCUIT NO FOREMAN #2 2305E072 2305E076 MAPPING JOINT FACILITIES ARRANGEMENTS UTILITY CONTACT PHONE # Incident #MAOP: Gas Order Elect Order N/A SCALE 1 /1 USE UMAP FROM "MAPVIEWER" ONLY CABLE INFO CABLE INFO 6/1/2025 SAP W.O. # 101188468, 108166272, 594166173MAP BOOKPAGE # ____GRID REF # 311074-166976/1/2025 N/A RENTON 6/1/2025253-208-9480 253-208-9480 253-208-9480 CABLE INFO 2305E072 KING GRA-15 N/A N/A CSPSKEPM 7651006 PM JENNY CHAU 253-208-9480 HH FARGO REPLACEMENT510 S 3RD ST # RENTON PM JENNY CHAU 253-208-9480 101188468 HH FARGO REPLACEMENT ~ CREW TO PARK AT HH1 AND V01 (317811-165999, 317824-166005) ~ CREW TO REPLACE EGGSHELL FARGO WITH NEW FARGOS(HH1) ~ INSTALL (3) 6 POS CONN BAR - MID 7651006 HH1 V01 MFP25003490 S 3RD STB1B2B3B4B5B6B7B8B9B10FUT1FUT2FUT3FUT4PED1PED2PED3PED4PED5T1T2T3T4T5S3S1S4S5S2L1L2PED626HOR: 1"=10' APRIL 2025CAG-25-044KPGTS, ECTS, EC, BDJTJJ.T. JOHNSON, G. ESTEPCITY OF RENTONVERTICAL: NAVD 1988HORIZONTAL: NAD 1983/19911-800-424-5555 or 811UNDERGROUND SERVICECall 48 HoursBefore You DigNO.BYDATEREVISION COMMENTSAPPRBID SET30World Cup Legacy Square - Phase 1Community & Economic Development,Public Works, Parks & RecreationLUA25-000065 C25-001240PR25-000020 TRO-41-4345 NILLUMINATION AND INTERCONNECT PLANE1.0ELECTRICAL NOTES:1.ALL WORK SHALL BE DONE IN ACCORDANCE WITH CODES AS ADOPTED BY THE CITY OFRENTON, KING COUNTY, AND THE STATE OF WASHINGTON.2.REFER TO TESC AND DEMOLITION PLAN FOR DEMOLITION, SALVAGE, AND STOCKPILECOORDINATION OF EXISTING LUMINAIRES AND J-BOXES.3.REFER TO CIVIL SHEETS FOR FINISHED GRADES.4.J-BOX LOCATIONS AND CONDUIT ROUTING ARE SCHEMATIC, ALIGN ALL JUNCTIONBOXES WITH PAVEMENT JOINTS IF FEASIBLE. CONDUIT ROUTING SHALL AVOID CRITICALROOT ZONE. IF CONDUIT MUST BE ROUTED WITHIN THE CRITICAL ROOT ZONE, CITYARBORIST TO BE PRESENT DURING INSTALLATION. CONTRACTOR TO SUBMIT CONDUITAND J-BOX LAYOUT PLAN TO OWNER'S REP PRIOR TO INSTALLATION.5.MAINTAIN AND PROTECT ALL EX UNDERGROUND UTILITIES. CONTRACTOR TO LOCATEALL EX UTILITIES PRIOR TO ANY EXCAVATION. PRIOR TO STARTING CONSTRUCTION,CONTRACTOR SHALL CALL 811 LOCATES FOR UTILITY LOCATIONS.6.ALL SPARE/EMPTY CONDUIT TO BE PROVIDED WITH NYLON PULL STRINGS.7.ALL J-BOXES AND CONDUITS ARE SHOWN IN APPROXIMATE LOCATIONS. VERIFYLOCATION OF PROPERTY LINE, EASEMENTS, AND UTILITIES PRIOR TO PLACEMENT.8.CAP ALL UNUSED CONDUITS. WHERE CONDUITS ARE CAPPED MARK LOCATION WITHAN ELECTRICAL MARKER.9.FIELD BENDING OF STRAIGHT CONDUIT SECTIONS INTO LONG RADIUS SWEEPS ISPREFERRED.10.GROUND ALL IN-GROUND J-BOXES, HAND HOLES, AND PULL BOXES PER MOSTCURRENT VERSION OF THE NEC.11.ELECTRICAL DESIGN AND ROUTING WITHIN STAGE AREA TO BE COMPLETED DURINGPHASE 2 AND IS NOT INCLUDED AS PART OF THIS CONTRACT.ELECTRICAL LEGENDAPPROX LIMITS OF WORK4-INCH CONDUIT2-INCH CONDUIT1-INCH CONDUITCONCRETE BENCHLIGHTINGFUTSAL COURTLUMINAIREPEDESTRIANLUMINAIREJ-BOX TYPE 8J-BOX TYPE 2STEP LIGHTSBOLLARDRECEPTACLERECESSED TREEUPLIGHT FIXTURELANDSCAPINGSPOTLIGHTFIXTURERELOCATEDSERVICE CABINETELECTRICAL CONCPADFOR WIRE NOTES SEE SHEET E1.1T-4345014/15/2025 27HOR: 1"=10' APRIL 2025CAG-25-044KPGTS, ECTS, EC, BDJTJJ.T. JOHNSON, G. ESTEPCITY OF RENTONVERTICAL: NAVD 1988HORIZONTAL: NAD 1983/19911-800-424-5555 or 811UNDERGROUND SERVICECall 48 HoursBefore You DigNO.BYDATEREVISION COMMENTSAPPRBID SET30World Cup Legacy Square - Phase 1Community & Economic Development,Public Works, Parks & RecreationLUA25-000065 C25-001240PR25-000020 TRO-41-4345N ILLUMINATION DETAILSE1.1SCALE:ONE LINE DIAGRAMN.T.S.1-LUMINAIRE #POLE NORTHINGPOLE EASTINGLUMINAIRE TYPELUMINAIRE ARMMOUNTINGHEIGHTPOLE BASEPOLE ID #CIRCUIT #COMMENTSFUT1EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1FUT2EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1FUT3EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1FUT4EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1PED1EXISTING 40WEXISTINGEXISTINGEXISTING5RELOCATED EXISTING POLE, ARM, AND FIXUREPED2EXISTING 40WEXISTINGEXISTINGEXISTING5RELOCATED EXISTING POLE, ARM, AND FIXUREPED3EXISTING 40WEXISTINGEXISTINGEXISTING5RELOCATED EXISTING POLE, ARM, AND FIXUREPED4EXISTING 40WEXISTINGEXISTINGEXISTING5RELOCATED EXISTING POLE, ARM, AND FIXUREPED5EXISTING 40WEXISTINGEXISTINGEXISTING5RELOCATED EXISTING POLE, ARM, AND FIXUREPED6EXISTING 40WEXISTINGEXISTINGEXISTING5RELOCATED EXISTING POLE, ARM, AND FIXURELUMINAIRE SCHEDULE - FOR POLES ONLYTYPELOCATIONDESCRIPTIONMOUNTINGDESCRIPTIONVOLTAGEWATTAGELAMP TYPECOLOR /TEMPERATUREFIXTURE FINISHDRIVER/ POWERSUPPLYCONTROLSDESCRIPTIONNOTESS#STAIRSEE URBAN DESIGNDETAILSSISTEMALUX NANELED ROUND RECESSED WALL LUMINAIRE S.3354N. POLYCARBONATE BODY WITHSTAINLESS STEEL TRIP. OPAL POLYCARBONATE DIFFUSER. CONCRETE WALL BACK BOX CAS3254.120-277V AC1.25WLED; CRI90WHITE/4000KSTAINLESS STEELOUTDOOR 75WCONTROL FROMSERVICE CABINETT#TREESEE URBAN DESIGNDETAILSKIM LIGHTING LIGHTVAULT RGBW LTV81FF, FLAT FRAME, NARROW FLOOD, SLIP-RESISTANT LENS120-277V AC30W24 LEDRGBWFLAT FRAME350 mABLUETOOTHL#LANDSCAPINGSEE URBAN DESIGNDETAILSKIM LIGHTING LIGHTVAULT RGBW LTV81EB, FLAT FRAME, NARROW FLOOD120-277V AC16W12 LEDRGBWEYEBALL350mABLUETOOTHB#BENCHSEE URBAN DESIGNDETAILSKELVIX RGBW-2, WET RATED24V DC7W PER FTLEDRGBWBLUETOOTHLUMINAIRE SCHEDULE - OTHER FIXTURES#S1LOCATION: S 3RD STSERVING: ILL, RECVOLTS: 120 /240 PHASE:1MAIN BREAKER: 200 AMPS WIRE: 3CKT#LOAD DESCRIPTIONKVATRIPAMPSTRIPAMPSKVALOAD DESCRIPTIONCKT#1ILLUMINATION (FUT1,2,3,&4)3.8420302.54STEP LIGHTS/ BENCH LIGHTS2150.62TREE UPLIGHTS/ LANDSCAPEUPLIGHTS45ILLUMINATION(PED1,2,3,4,5,&6)0.2920201.50RECEPTACLE6150.30LIGHTING CONTROL89---201.50GFI CABINET RECEPTACLE10---1213------14---16REMARKS: LIGHTING CONTROL IS PHOTOCELLMOUNTED ON CABINET FOR CKT #1 & CKT #5.CONNECTED LOAD: 10.59 KVA 88.25 AMPSDEMAND LOAD (125%): 13.24 KVA 110.32 AMPSPANEL SCHEDULECKT #1: 2-#8CKT #2: 2-#8GRND: 1-#8CKT #2: 2-#8GRND: 1-#8CKT #1: 2-#8GRND: 1-#8CKT #1: 2-#8CKT #5: 2-#8GRND: 1-#8CKT #2: 2-#8GRND: 1-#8CKT #2: 2-#8GRND: 1-#8CKT #1: 2-#8CKT #5: 2-#8GRND: 1-#8CKT #1: 2-#8CKT #5: 2-#8GRND: 1-#8CKT #5: 2-#8GRND: 1-#8CKT #2: 2-#8GRND: 1-#8CKT #2: 2-#8CKT #4: 2-#8GRND: 1-#8CKT #4: 2-#8GRND: 1-#8CKT #2: 2-#8GRND: 1-#8CKT #4: 2-#8GRND: 1-#8CKT #5: 2-#8GRND: 1-#8CKT #4: 2-#8GRND: 1-#8CKT #6: 2-#6GRND: 1-#6CKT #4: 2-#8GRND: 1-#8SERVICE FEEDER: 3-#3/0NEED LOCATIONS OFRECEPTACLESRACEWAY/ CONDUIT SIZECONDUCTORSCOMMENTS2"SPARE4"SPARE2"2-#8 FUT ILL, 1-#8 GRND2"COMMUNICATION SPARE2"2-#8 STP & BNCH ILL, 1-#8 GRND2"IRRIGATION WIRINGPER MANUFACTURER RECOMMENDATIONS2"2-#8 FUT ILL, 2-#8 PED ILL, 1-#8 GRND2"2-#8 PED ILL, 1-#8 GRND1"2-#8 UP ILL, 1-#8 GRND2"2-#8 UP ILL, 1-#8 GRND2"2-#8 UP ILL, 2-#8 STP & BNCH ILL, 1-#8 GRND1"RECEPTACLE BOLLARD SPARE4"2-#8 FUT ILL, 2-#8 PED ILL, 2-#8 UP ILL, 2-#8 STP & BNCH ILL, 1-#8 GRND3"3-#2/0SERVICE FEEDER WIREWIRE NOTESCKT #1: 2-#8CKT #2: 2-#8CKT #4: 2-#8CKT #5: 2-#8GRND: 1-#8T-4345024/15/2025LUMINAIRE #POLE NORTHINGPOLE EASTINGLUMINAIRE TYPELUMINAIRE ARMMOUNTINGHEIGHTPOLE BASEPOLE ID #CIRCUIT #COMMENTSFUT1178164.041300050.96EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1FUT2178097.771299991.82EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1FUT3178066.011300028.08EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1FUT4178136.551300085.50EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1EVOLVE EALP 03, N4, AF, 70CRI, 4000K, N, D, S1,GRAY, L, 400WKNUCKLESLIPFITTER30 FTFIXED1PED1178137.371300124.31EXISTING 40WEXISTINGEXISTINGEXISTING5RELOCATED EXISTING POLE, ARM, AND FIXUREPED2178124.671300170.07EXISTING 40WEXISTINGEXISTINGEXISTING5RELOCATED EXISTING POLE, ARM, AND FIXUREPED3178085.681300173.35EXISTING 40WEXISTINGEXISTINGEXISTING5RELOCATED EXISTING POLE, ARM, AND FIXUREPED4178063.731300135.78EXISTING 40WEXISTINGEXISTINGEXISTING5RELOCATED EXISTING POLE, ARM, AND FIXUREPED5178089.021300108.35EXISTING 40WEXISTINGEXISTINGEXISTING5RELOCATED EXISTING POLE, ARM, AND FIXUREPED6178059.851300003.31EXISTING 40WEXISTINGEXISTINGEXISTING5RELOCATED EXISTING POLE, ARM, AND FIXURE 1'-3"9"FRONT ELEVATION:LID CLOSEDSIDE ELEVATION:LID CLOSEDFRONT ELEVATION:LID OPEN4"LOCKABLE FLIP COVERWITH CAPTIVE TAMPERRESISTANT SCREWMACHINEDALUMINUM HOUSING,BLACK WRINKLE FINISHCONC FOOTING, TYP4"1 34"516"6"4"1'-6"6"516"4"1 34"3"FLUSHPLANGFI DUPLEXRECEPTACLE 20A-NEMA 5/20ROPENING FORCORD SETS (2)FINISH GRADE, TOPOF PAVING, SEEGRADING PLANSATTACH HOUSING STEELPLATE, METAL BASE, ANDPVC HOUSING PERMANUFACTURER'SREQUIREMENTSCONC FOOTING, TYPPVC HOUSING WITH (2)PRIMARY SLIP CONNECTORSRECEPTACLEBOLLARDLCLC3"4"3"CONC FOOTING10"SECTION AA-9'-0"3'-0"NO. 4 HOOP TIES AT 12" O.C.WITH (3) HOOPS TOP AT 2" O.C.(12) NO. 6 VERT. EQUALLYSPACEDFINISH GRADE, SEEGRADING PLANSFUTSAL POLEBASE PLATE AND ANCHOR BOLTS PERMANUFACTURER REQUIREMENTSVERTICAL REINFORCEMENTPER ELEVATION36" DIA AUGERCASTCONC FOUNDATIONTIES PER ELEVATION5 12" THREADEXPOSURE3'-0"EMBEDMENTDEPTHCONDUITS28HOR: 1"=10' APRIL 2025CAG-25-044KPGTS, ECTS, EC, BDJTJJ.T. JOHNSON, G. ESTEPCITY OF RENTONVERTICAL: NAVD 1988HORIZONTAL: NAD 1983/19911-800-424-5555 or 811UNDERGROUND SERVICECall 48 HoursBefore You DigNO.BYDATEREVISION COMMENTSAPPRBID SET30World Cup Legacy Square - Phase 1Community & Economic Development,Public Works, Parks & RecreationLUA25-000065 C25-001240PR25-000020 TRO-41-4345 ELECTRICAL DETAILS (1 OF 2)E1.2SCALE:RECEPTACLE BOLLARDN.T.S.1E1.0SCALE:FUSTAL POLE FOUNDATION DETAIL1" = 1'-0"2E1.0T-4345034/15/2025 29HOR: 1"=10' APRIL 2025CAG-25-044KPGTS, ECTS, EC, BDJTJJ.T. JOHNSON, G. ESTEPCITY OF RENTONVERTICAL: NAVD 1988HORIZONTAL: NAD 1983/19911-800-424-5555 or 811UNDERGROUND SERVICECall 48 HoursBefore You DigNO.BYDATEREVISION COMMENTSAPPRBID SET30World Cup Legacy Square - Phase 1Community & Economic Development,Public Works, Parks & RecreationLUA25-000065 C25-001240PR25-000020 TRO-41-4345 ELECTRICAL DETAILS (2 OF 2)E1.3SCALE:SERVICE CABINET DETAILN.T.S.5E1.0SCALE:SERVICE CABINET NOTESN.T.S.6E1.0SCALE:STRAIN RELIEF DETAILN.T.S.1E1.0SCALE:LUMINAIRE ELECTRICAL WIRING SYSTEMN.T.S.2E1.0SCALE:LUMINAIRE CONC PAD/ SIDEWALK AND J-BOX CONC PADN.T.S.3E1.0SCALE:LUMINAIRE STD DECAL NUMBERING SYSTEMN.T.S.4E1.0SCALE:LIGHT BASE AND J-BOX LOCATIONN.T.S.7E1.0SCALE:TRANSPORTATION NOTESN.T.S.8E1.0T-4345044/15/2025