Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M_Material_Submittal_20250717_V2
Model F1FR56 UprightModel F1FR56 Pendent Model F1FR56 Horizontal Sidewall Model F1FR56 Vertical Sidewall Note: Not all versions of the product are shown. F1FR Series Sprinkler Summary Sprinkler Model K-Factor gpm/psi1/2 (lpm/bar1/2)Orientation Listings & Approvals Max. Working Pressure psi (bar) Sprinkler Identification Number (SIN) F1FR56 5.6 (80) Upright Intermediate Upright cULus, FM, LPCB, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1425 Pendent cULus, FM, LPCB, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1414 Concealed Pendent cULus, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1414 Horizontal Sidewall cULus, FM 175 (12)RA1435 Vertical Sidewall cULus, FM, LPCB, UKCA 175 (12)RA1485 Table A Note: This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Iden- tification Number (SIN), application, performance, and listings/ approval are not otherwise affected. Sprinklers with New frames will include the suffix “N” in the order. Features • Standard coverage quick-response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Low profile, compact design • Available in a wide variety of finishes Product Description Reliable Model F1FR56 series sprinklers are quick-response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed or concealed, the Model F1FR56 series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons and cover plates. Refer to the technical information on the following pages for specific listings for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. When fitted with an approved water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Table A provides a summary of the approvals and availability of specific Model F1FR series sprinkler configurations. Additional technical information for each sprinkler model is provided on the following pages. www.reliablesprinkler.com K-factor 5.6 (80) F1FR56 Series Quick Response Sprinklers Bulletin 074 November 2023 F25003247 V2 REVISION Received: 07/18/2025 / PMAlexander BUILDING DIVISION By: hsotelo Date: 07/23/2025 FIRE DEPARTMENT For Construction Subject to Corrections Noted in Red APPROVED Model F1FR56 Upright Sprinkler SIN RA1425 Technical Specifications Style: Upright, Intermediate Upright Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Guards & Shields (New Frames) Factory Water Shield (cULus, FM) F-1 Guard (cULus, FM) F-3 Guard with Shield (cULus, FM) Guards and Shields (Legacy Frames) Factory Water Shield C-1 Guard (FM) C-3 Guard with Shield (cULus, FM) D-1 Guard (cULus) D-3 Guard with Shield (cULus) Sprinkler Wrench Model W2 Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals cULus Listed FM Approved LPCB VdS EC WM UKCA: 0832-UKCA-CPR-S5045 Model F1FR56 Upright Sprinkler Components and Dimensions Figure 1 Deflector Glass Bulb (3 mm) Wrench Flat Threads 1 3/8" [33mm] 3 1/4" [83mm] Cap/Seal Assembly Load Screw 2 1/4" [58mm] F1FR_HALF_UPR_INT Shown with Optional Factory Installed Water Shield ( Intermediate Upright) Bulletin 074 November 2023 Page 2 of 9 www.reliablesprinkler.com 7-16-25 Model F1FR56 Pendent Sprinkler SIN RA1414 Technical Specifications Style: Pendent Recessed Pendent Concealed Pendent Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings(1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Recessed Escutcheons Model F1 (cULus, LPCB, VdS, CE, WM) Model F2 (cULus, FM, LPCB, VdS, CE, WM) Model FP (cULus, VdS, CE, WM) Cover Plate Model CCP (cULus, VdS(2), CE(2)) Guards & Shields (New Frames)(3) F-1 Guard (FM) F-5 Guard/Shield Kit (FM) F-7 Guard (cULus) F-8 Guard/Shield Kit (cULus) S-1 Shield (cULus, FM) Guards & Shields (Legacy Frames)(3) C-1 Guard (FM) C-5 Guard/Shield Kit (FM) D-1 Guard (cULus, FM) D-4 Guard/Shield Kit (FM) D-5 Guard/Shield Kit (cULus, FM) S-1 Shield (cULus, FM) Sprinkler Wrenches Model W2 (pendent) Model W4 (recessed or concealed) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals(4) cULus Listed FM Approved LPCB VdS EC WM UKCA: 0832-UKCA-CPR-S5045, 0831-UKCA-CPR-5072 (CCP) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed or concealed use. 2. VdS and CE approval for CCP concealed use is for 155°C (68°C) sprinkler ONLY. 3. Not suitable for recessed or concealed pendent installations. 4. When used surface mounted or exposed. See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1FR56 Pendent Sprinkler Components and Dimensions Figure 2 F1FR_HALF_PEND_INT Deflector Glass Bulb(3 mm) Wrench Flat Threads 3 1/4" [83mm] 2 1/4" [57mm] 1" [25mm]Load Screw Cap/SealAssembly Shown with Optional S-1 WaterShield (Ordered Separately) Note: Please refer to Figure 8 for recessed and concealed installation. Bulletin 074 November 2023 Page 3 of 9 www.reliablesprinkler.com Model F1FR56 Horizontal Sidewall Sprinkler SIN RA1435 Technical Specifications Style: Horizontal Sidewall Recessed Horizontal Sidewall Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Recessed Escutcheons(2) Model F1 (cULus) Model F2 (cULus, FM) Model FP (cULus) Guards & Shields (New Frames)(3) F-4 Guard (FM) F-7 Guard (cULus) Guards & Shields (Legacy Frames)(3) C1 Guard (FM) D1 Guard (cULus) Sprinkler Wrenches Model W2 (non-recessed) Model W4 (recessed)Model J (New frame with guard installed)Model JD (Legacy frame with guard installed) Listings and Approvals cULus Listed(4) FM Approved(5) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed use. 2. FM approved recessed installation when used with Model F2 escutcheon ONLY. 3. Not suitable for recessed horizontal sidewall installations. 4. cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. Listed for Light Hazard ONLY when installed recessed. 5. FM Approved for Light Hazard ONLY. Model F1FR56 Horizontal Sidewall Sprinkler Components and Dimensions Figure 3 Bulletin 074 November 2023 Page 4 of 9 www.reliablesprinkler.com F1FR_HALF_HSW 2 3/4" [70mm] 1 1/8" [28mm] Threads Cap/Seal Assembly Load ScrewDeflector Glass Bulb (3 mm) Wrench Flat Frame Note: Please refer to Figure 9 for recessed installation. Model F1FR56 Vertical Sidewall Sprinkler SIN RA1485 Technical Specifications Style: Upright Vertical Sidewall Pendent Vertical Sidewall Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Guards & Shields (New Frames) F-2 Guard (FM) Guards & Shields (Legacy Frames) C1 Guard (FM) Sprinkler Wrenches Model W2 Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals(1) cULus Listed FM Approved LPCB(2) UKCA: 0832-UKCA-CPR-S5045 Notes: 1. Listed and approved for Light Hazard ONLY. 2. LPCB approved for use in pendent position ONLY. Model F1FR56 Vertical Sprinkler Components and Dimensions Figure 4 Bulletin 074 November 2023 Page 5 of 9 www.reliablesprinkler.com F1FR_HALF_VSW 2 1/4" [57mm] 1 1/2" [38mm] Threads Cap/Seal Assembly Load ScrewDeflector Glass Bulb (3 mm) Wrench Flat Frame Models F1 & F1FR Pendent Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment 2-7/8" (72 mm) Dia. 1-3/4"(44 mm) 2-1/4" (57 mm) Dia.Hole in Ceiling 1-15/16"(49 mm) Dia. Minimum Recess Maximum Recess 1"(25 mm) Face of Fitting to Face of Ceiling1-1/8" (29 mm) at Max. Recess 3/8" (10 mm) atMin. Recess Models F1 & F1FR Pendent Sprinklerwith Model FP Recessed Escutcheon1/2" (13mm) Nominal Adjustment 1" (25 mm) 2-5/16"(59 mm) Dia. MinimumRecess MaximumRecess 1/2" (12 mm) 3-3/16" (78 mm) Dia. Face of Fitting to Face of Ceiling 1-1/2" (38 mm) atMax. Recess 1" (25 mm) atMin. Recess 2-7/8" (72 mm) Dia. 1-3/4"(44 mm) Minimum Recess Maximum Recess 1-1/4" (32 mm) Face of Fittingto Face of Ceiling 7/8" (22 mm) at Max. Recess3/8" (10 mm) at Min. Recess 2-1/4" (57 mm) Dia.Hole in Ceiling 1-15/16"(49 mm) Dia. 2-1/2" (64 mm) Dia.Hole in Ceiling Models F1 & F1FR Pendent Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment ReducingFitting ReducingFitting ReducingFitting Note: Model FP recessed assemblies may not be used where thepressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model FP cupare unobstructed following installation. Vented Cup Model F1FR56 CCP Conical Concealed Sprinkler1/2" (13mm) Nominal Adjustment (Nominal Cover Plate Projection is 1" (25 mm)) 1" (25 mm) 2-5/16"(59 mm) Dia. MinimumRecess MaximumRecess 1/2" (12 mm) 3-5/16" (84 mm) Dia. Face of Fitting to Face of Ceiling 1-1/2" (38 mm) atMax. Recess 1" (25 mm) atMin. Recess 2-1/2" (64 mm) Dia.Hole in Ceiling F1_REC_PEND_CCP ReducingFitting Note: Model CCP concealed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in theModel CCP cup are unobstructed following installation. Vented Cup Recessed and Concealed Installation: Pendent Sprinklers Figure 5 FP EscutcheonF1 Escutcheon (F2 Similar) CCP Cover Plate Bulletin 074 November 2023 Page 6 of 9 www.reliablesprinkler.com 2-1/4" (57 mm) Dia. Hole 1-15/16" (49 mm) Dia. 2-1/4" (57 mm) Dia. Hole 1-15/16" (49 mm) DIA. 2-7/8" (73 mm) Dia. 2-7/8" (73 mm) Dia. 2-1/8" (54 mm) Minimum Recess 1-5/8" (42 mm) Maximum Recess 2 1/8" (54 mm) Minimum Recess 1-3/8" (35 mm) Maximum Recess 2-5/8" (67 mm) DiaHole. 2-5/16"(58 mm)Dia. 3-1/4" (83 mm) Dia. 1-1/4" (32 mm) +/-1/4" (6 mm) Face of fitting to face of wall 1-3/8" (35 mm) Minimum Recess 7/8" (22 mm) Maximum Recess 3/8" (16 mm) +/-1/4" (6 mm) Face of fitting to face of wall 1/2" (12 mm) +/- 3/8" (10 mm) Face of fitting to face of wall 4" - 12" (102 mm - 305 mm) Deflector to ceiling F1FR_REC_HSW Reducing Fitting Reducing Fitting ReducingFitting 9/16" [14mm] Model F1FR Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Model F1FR Horizontal Sidewall Sprinklerwith Model F2 Recessed Escutcheon1/2" (13mm) Nominal Adjustment Model F1FR Horizontal Sidewall Sprinklerwith Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment F2 Recessed escutcheon 1/2" (13 mm) Adjustment F1 Recessed escutcheon 3/4" (19 mm) Adjustment 4" - 12" (102 mm - 305 mm) Deflector to ceiling 9/16" [14mm] 4" - 12" (102 mm - 305 mm) Deflector to ceiling 9/16" [14mm] Note: Model FP recessed assemblies may not be used where thepressure in the space behind the sprinkler is positive with respect to the space in the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Vented Cup Recessed Installation: Horizontal Sidewall Sprinklers Figure 6 Bulletin 074 November 2023 Page 7 of 9 www.reliablesprinkler.com Installation Model F1FR Series sprinklers must be installed in accordance with NFPA13 and the requirements of all applicable authorities having jurisdiction. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in this Bulletin. Any other wrench may damage the sprinkler. The Models W2 and W4 wrenches have two sets of jaws. Use the smallest set of jaws that fit on the wrench flats of the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N.m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Glass bulb sprinklers have orange bulb protectors or protective caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Standard Finishes Special Application Finishes Sprinkler F1, F2 and FP(2) Escutcheons CCP Cover Plate(2)Sprinkler F1, F2 and FP(2) Escutcheons CCP Cover Plate(2) Bronze Brass Chrome Electroless Nickel PTFE(3)(4)Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(5)Satin Chrome Satin Chrome White Polyester(3)White Polyester Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Polyester(3) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200°F (93°C) maximum temperature rated sprinklers only. Finishes(1)Table B Maintenance Reliable Model F1FR series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Wrenches Model W2 (upright, pendent) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed, similar but with zinc finish)Model W4 (recessed, concealed pendent) Bulletin 074 November 2023 Page 8 of 9 www.reliablesprinkler.com P/ N 9 9 9 9 9 7 0 6 2 3 Bulletin 074 November 2023 Page 9 of 9 www.reliablesprinkler.com Guarantee For the guarantee, terms, and conditions, visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon(1)(2) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F (57°C) [For use with 135°F (57°C) and 155°F (68°C) sprinklers.] • 165°F (74°C) [For use with 175°F (79°C) and 200°F (93°C) sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4 (recessed, concealed) • Model J (New frame with guard installed) • Model JD (Legacy frame with guard installed) Notes: 1. 286°F (141°C) sprinklers are not listed to be used recessed or concealed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon. FLEXHEAD® FLEXIBLE FIRE SPRINKLER CONNECTIONS THE FLEXHEAD ADVANTAGE 02 INSTALLATION COMPARISON 03 NFPA 13 CODE LANGUAGE & 04 SEISMIC QUALIFICATIONS PRODUCTS 06 FRICTION LOSS DATA & SPECIFICATIONS 10 FLEXHEAD CEILING DETAILS 12 BRACKET SPECIFICATION SHEET 14 FLEXHEAD COMMERCIAL PRODUCTS 15 FLEXHEAD STANDARD SPECIFICATIONS 16 ANVIL BRANDS 18 CUSTOMER SERVICE CENTERS 20 FLEXHEAD® 2 • BEST CORROSION RESISTANCE Made from 100% 304 stainless steel • EXCELLENT FRICTION LOSS VALUES One-inch true-bore ID reducing the need to upsize mains and branch lines, 1¼" ID available • PRESSURE SURGE PROTECTION Fully braided connection improves pressure capability and prevents hose damage • HIGHEST MAXIMUM WORKING PRESSURE Available up to 300 PSI • NO O-RINGS OR GASKETS Welded connections reduce potential leak points at the inlet and outlet fitting • TIGHTEST THREAD TOLERANCES Outlet fitting threads are machined from solid bar stock reducing potential leaks at the sprinkler head fit-up • EXTRA STABILITY BRACKET A full 6-inch base to stabilize the sprinkler head during installation, pressurization or activation The Flexhead® Advantage • Is seismically qualified, eliminating the need for an oversized ring around the sprinkler head in seismic areas • Has the same product design that is dual listed by both UL and FM • Can be produced to meet all your project requirements • Hoses have serial identification with complete audit tracking of finished goods • Hose has comprehensive limited warranty backed by an A++ insurance company • Offers a variety of flexible fire sprinkler connections, suspended ceilings, gypsum board ceilings, freezer, coolers, institutional applications, cleanroom and duct applications • Offers 1.25" FlexHead® hose for superior friction loss numbers • The 3" Tall MPT Bracket allows the sprinkler to install the FlexHead® system without touching the ceiling tile QUALITY FEATURES BUILDING CONNECTIONS THAT LAST 3 WANT PINPOINT LOCATIONS? NO PROBLEM. The design makes it easy to accurately locate sprinkler heads every time. If the spec calls for center-of-tile placement, you can do it with ease. In fact, you get center-of-tile placement every install whether the spec calls for it or not. It takes one more headache out of specifying and bidding. ACCOMMODATE FLOOR PLAN CHANGES. Need to relocate sprinkler heads? No problem. With its built-in flexibility it’s much easier to move heads to a new location to accommodate new layouts or uses of the space. FlexHead systems connect sprinkler heads to sprinkler sub-mains in about a quarter of the time it takes to install hard pipe. Expect even greater savings in retrofits, where FlexHead installs six to seven times faster than hard pipe. Increase productivity with the ease of installation, no need to install hangers and there is no on-site assembly required. Every sprinkler connection is a finished, pre-constructed assembly, from the 1" pipe connector to the sprinkler head outlet. In addition, FlexHead provides seismic protection to sprinkler heads allowing for deflection during a seismic event. 4 FLEXHEADSHEADS INSTALLED 1 HARD-PIPE 4 FLEXHEADSHEADS INSTALLED 1 HARD-PIPE Connect sprinkler heads to sub-mains at least four times faster. During a typical installation, a minimum of four FlexHeads can be installed in the same time it takes to do one hard-pipe. One Hard-PipeOne Hard-Pipe Four Flexhead Six Flexhead During a typical installation, a minimum of six FlexHeads can be installed in the same time it takes to do one hard-pipe. Retrofits in less time. NEW CONSTRUCTION COMPARISON RETROFIT COMPARISON RETROFITS IN LESS TIME. Need to comply to code in unsprinklered buildings? In contrast to costly and labor-intensive hard-pipe retrofits, FlexHead connections install in minutes in even the most restrictive spaces. SHORTEN YOUR TIME TO OCCUPANCY. Faster installation times help get end-users into their spaces more quickly—and get installers on their next projects faster. FlexHead connections virtually eliminate punch list items commonly found with hard-pipe armovers. FLEXHEAD® 4 NFPA 13 CODE LANGUAGES & SEISMIC QUALIFICATION 17 .4.1.3.3* Flexible Sprinkler Hose Fittings 17.4.1.3.3.1 Listed flexible sprinkler hose fittings and their anchoring components intended for use in installations connecting the sprinkler system piping to sprinklers shall be installed in accordance with the requirements of the listing, including any installation instructions. 17.4.1.3.3.2 When installed and supported by suspended ceilings, the ceiling shall meet ASTM C635/C635M, Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-In Panel Ceilings, and shall be installed in accordance with ASTM C636/C636M, Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels. 17.4.1.3.3.3* Where flexible sprinkler hose fittings exceed 6 ft (1.8 m) in length and are supported by a suspended ceiling in accordance with 17.4.1.3.3.2, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft (1.8 m) . 17 .4.1.3.3.4* Where flexible sprinkler hose fittings are used to connect sprinklers to branch lines in suspended ceilings, a label limiting relocation of the sprinkler shall be provided on the anchoring component. Reproduced with permission of NFPA from NFPA 13, Standard or the Installation of Sprinkler Systems, 2019 edition. Copyright© 2018, National Fire Protection Association. For a full copy of NFPA 13, please go to www.nfpa.org. This material is not affiliated with nor has it been reviewed or approved by the NFPA. NFPA 13 STANDARDS FOR INSTALLATION OF SPRINKLER SYSTEMS 2019 BUILDING CONNECTIONS THAT LAST 5 FLEXHEAD® SATISFIES SEISMIC CODE REQUIREMENTS •More than 90% of the states in the U.S. are adopting the International Building Code (IBC) that address, among other things, the installation of fire sprinkler systems in seismic zones. •The latest version of the IBC defers to ASCE 7 and ASTM E580/580M-17 for the sprinkler/ceiling design in Seismic Design Categories C and D, E & F. •In Seismic Design Category C, suspended ceilings are to be designed and installed in accordance with Ceilings & Interior Systems Construction Association (CISCA) recommendations for Zones 0-2; and sprinkler heads and other penetrations shall have a minimum of 1⁄4 inch clearance on all sides. •In Seismic Design Categories D, E & F, suspended ceilings are to be designed and installed in accordance with CISCA recommendations for seismic Zones 3 and 4 with some additional requirements. Except where rigid braces are used to limit lateral deflections, sprinkler heads and other penetrations shall have a 2-inch oversized ring, sleeve, or adapter through the ceiling to allow for free movement of at least 1 inch of ceiling movement in all horizontal directions. •Flexible sprinkler connection provide characteristics that exceed the most stringent seismic code requirements. The flexibility of the hose allows the head to move with the ceiling in any direction during a seismic event without causing damage to the sprinkler system. FlexHead® satisfactorily completed full-scale seismic qualification testing at the Structural Engineering Earthquake Simulation Laboratory located at the State University of New York at Buffalo. Tests were conducted using the International Code Council (ICC) acceptance criteria “ICC-ES AC-156 Seismic Qualification Testing of Nonstructural Components”. The FlexHead® hose allows the head to move in any direction during a seismic event without causing damage to the sprinkler system. FlexHead® Mounting Bracket FLEXHEAD® 6 FLEXIBLE FIRE SPRINKLER CONNECTIONS •Has undergone full-scale head deployment testing •Is seismically qualified for use in Seismic Design Categories D, E & F •Is made of 100% 304 stainless steel including end fittings •Is fully welded without the need for o-rings or gaskets THE ONLY PRODUCT THAT: •UL Listed/ FM Approved •Undergone full-scale head deployment testing •Seismically qualified for use in Seismic Design Categories C, D, E & F •Made of 100% 304 stainless steel including end fittings •Every FlexHead hose is leak tested before shipment •Fully welded 304SS hose doesn't contain any O-rings or gaskets FLEXHEAD®FLEXIBLE FIRE SPRINKLER CONNECTIONS •Available in hose lengths from 24" - 72" Designed to be installed in concrete walls or ceiling penetrations •Available with open hub UHO-3 bracket for easier installation •Easy installation in tight spaces •UL Listed / FM Approved INSTITUTIONAL FLEXIBLE FIRE SPRINKLER CONNECTIONS We invented the concept of Flexible Fire Protection™. All our flexible sprinkler pipe and connections are UL Listed and/or FM Approved. BUILDING CONNECTIONS THAT LAST 7 •Best flow characteristics for flexible drops in the industry •1¼" NPT Standard, and 1¼" SLT integrated coupling option available •Great for tenant improvement projects, similar flow characteristic to 1" pipe •FM Approved •No need to measure or count the number of bends, 72" SuperFlex hose is UL listed for up to (12) bends •Increased bends create more flexibility during installation •All Welded, no o-rings •Quick inspections and sign offs by AHJ’s for final walkthrough •Available with MPT (Multi-positional tail) mounting bracket. No need to touch the ceiling tile during installation. •Also available with Adjustable ADO24BKT3 mounting bracket. •UL Listed / FM Approved •Suitable for wet sprinkler systems with a dry pendent sprinkler head (Dry pendant sprinkler head not included) •Mounts on the top of freezer or sidewall •Moves and flexes along with the structure protecting the integrity of the freezer seal •Now available with a Drain Tee •FM Approved •Fast and easy installation with 1" integrated SlideLOK® Coupling •Comes fully assembled •UL listed for 2" bend radius, up to 12 bends per hose* (72"hose) •Eliminates taping or doping of threaded fittings •Flexible design provides versatility for changes in plan •Installs on a standard 1" Welded Outlet •UL Listed / FM Approved 1.25" I.D. HOSE WITH BEST FLOW CHARACTERISTICS SUPERFLEX® FLEXIBLE FIRE SPRINKLER CONNECTIONS FLEXIBLE FIRE SPRINKLER DRY PENDENT SYSTEM SUPERFLEX® FLEXIBLE FIRE SPRINKLER CONNECTION WITH PATENTED SLT TECHNOLOGY FLEXIBLE FIRE SPRINKLER CONNECTIONS FlexHead® systems connect sprinkler heads to sub-mains at least four times faster than hard pipe. Delivers even greater savings in retrofits. All our flexible sprinkler pipe and connections are UL Listed and/or FM Approved. FLEXHEAD® 8 •Superior height allows the “MPT” to be mounted without pre-installing the ceiling tile and comes out of the box fully assembled at 24" •Within seconds the MPT Bracket can be adjusted from 24" to 16” to 14 ½" in length accommodating numerous applications without additional fabrication •Adjustable Open Hub allows for swift & accurate repositioning at the 1/4 points •UL Listed / FM Approved NO TOUCH CEILING TILE TALL BRACKET MOUNTING SYSTEM (MPT24BKT1) •“Open Hub” design for quick and easy installation •Can be installed with " or ½" threaded rod attachments •The " rod is FM approved to be installed up to 4ft off the structure and the ½" threaded rod up to 6ft off the structure •Good option for temporary fire protection •Ideal for shell applications; easily transitions from UHO-3 to suspended ceiling bracket •FM Approved •FlexHead ADO16BKT3 and ADO24BKT3 can be installed in hard ceilings or sidewall applications. •For use with FlexHead hose model numbers 20XX, 20XXH, where XX designates hose length in inches. •FM Approved UHO-3 THREADED ROD INSTALLATION DRY WALL CEILING AND SIDEWALL INSTALLATION (ADO16BKT3 & ADO24BKT3) •The mounting bracket is specifically designed to be compatible with the Armstrong®TechZone™ suspended ceiling systems •FlexHead TechZone™ mounting bracelets allow for quick TechZone™ ceiling installations. The FlexHead TechZone™ system installs in a quarter of the time compared to typical black pipe armovers. •Allows for rapid installation or relocation of sprinkler heads in suspended ceilings •UL Listed / FM Approved ARMSTRONG® TECHZONE™ BRACKET MOUNTING SYSTEM FLEXIBLE FIRE SPRINKLER CONNECTIONS We invented the concept of Flexible Fire Protection™. All our flexible sprinkler pipe and connections are UL Listed and/or FM Approved. BUILDING CONNECTIONS THAT LAST 9 •FlexHead flexible sprinkler systems have been protecting exhaust ducts in semi-conductor/electronics facilities for more than thirty years •Quick installation, install in minutes •No need for inspection port •Available in Steel, FRP, Polypropylene, and PVC •Flexible hoses allow for independent motion (sway) between duct and water main to compensate for duct vibration and during possible seismic activity—eliminating potential leaks. •Allows for quick and easy inspection of sprinkler heads •FM Approved •Attach to structure with Anvil-Strut™ and pipe clamp •Drop nipple with reducer (not included) •Perfect for applications where you have a concrete deck above the ceiling which secures the flexible hose to the building structure. •This model will have a 1 inch female outlet •FM Approved •Custom manufactured for “walkable" cleanroom ceiling systems in Class 100 cleanrooms. •100% stainless-steel, one-piece system is leak-tested prior to shipping •Allows quick and easy relocation when floor plan changes due to reconfiguration of tool layout •Allows for independent motion (sway) between ceiling grid and water main to accommodate filter vibration and during possible seismic activity. •Eliminates potential leaks and protecting gel seals •Eliminates ceiling stress/leaks due to miss-aligned hard-pipe installation •FM Approved •Perfect for applications where you have limited space •The FlexHead Low-Profile Model uses traditional Anvil-Strut™ Channel (not included) to secure the FlexHead sprinkler hose to the building structure •FM Approved INDUSTRIAL/DUCT FLEXIBLE FIRE SPRINKLERS CONNECTIONS DROP NIPPLE FLEXIBLE SPRINKLER CONNECTIONS FOR ANVIL-STRUT™ CLASS 100 CLEANROOM FLEXIBLE FIRE SPRINKLER CONNECTIONS LOW-PROFILE FLEXIBLE FIRE SPRINKLER CONNECTIONS FOR ANVIL-STRUT™ FLEXIBLE FIRE SPRINKLER CONNECTIONS Whether your application is commercial, industrial, clean room, or institutional, FlexHead® flexible sprinkler systems can save you time and money by offering reliable, highly efficient, seismically qualified, and environmentally responsible products ARMSTRONG® TECHZONE™ BRACKET MOUNTING SYSTEM FLEXHEAD® 10 FRICTION LOSS DATA & SPECIFICATIONS Model Number Outlet Orifice Size Hose Assembly Length Minimum Bend Radius Maximum Number of 90˚ Bends Equivalent Length of 1in. Diameter Schedule 40 Pipe (Ft)Max Rated Pressure FM UL UL FM UL FM FM LU5.6k-factor 8.0k-factor 11.2k-factor 14.0k-factor 16.8k-factor 22.4k-factor in (cm)in (mm)in (mm)in (mm)in (mm)in (mm)Ft (mm)Ft (mm)Ft (mm)Ft (mm)Ft (mm)Ft (mm)Ft (mm)PSI/Kpa PSI/Kpa SUPERFLEX® 1" INTERNAL DIAMETER (I.D.) HOSE SERIES (Data equivalent for all end connection 1" NPT, 1" Cut Groove and SLT) 2036SF-50 1⁄2 (1.27) 36 (914) 7 (178) 2 (50.8) 5 2 30 (9.1)16.2 (4.9)16.9 (5.1)11.5 (3.5)––– 2048SF-50 48 (1219)8 3 47 (14.3)28.7 (8.7)29.3 (8.9)15.4 (4.7)––– 2072SF-50 72 (1828)12 4 71 (21.6)53.9 (16.4)54.3 (16.5)23.2 (7)––– 2036SF-75 3⁄4 (1.90) 36 (914) 7 (178) 2 (50.8) 5 2 29 (8.8)–21.5 (6.5)21.6 (6.5)21.8 (6.6)22 (6.7)– 2048SF-75 48 (1219)8 3 44 (13.4)–30.5 (9.2)30.6 (9.3)31.1 (9.4)30.8 (9.3)– 2072SF-75 72 (1828)12 4 70 (21.3)–48.5 (14.7)48.8 (14.8)49.9 (15.2)48.6 (14.8)– FLEXHEAD STANDARD TALL 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024T-50 1⁄2 (1.27) 24 (610) 8 (200) 3 (76.2) 3 1 11 (3.4)18.4 (5.6)7.7 (2.3)7.6 (2.3)––– 175 (1205)175 (1205) 2036T-50 36 (914)3 2 16 (4.9)26.6 (8.1)11.5 (3.5)11.5 (3.5)––– 2048T-50 48 (1219)4 3 24 (7.3)30.3 (9.2)15.3 (4.6)15.4 (4.7)––– 2060T-50 60 (1524)4 4 29 (8.8)35.8 (10.9)19.1 (5.8)19.3 (5.8)––– 2072T-50 72 (1828)4 4 35 (10.7)45.6 (13.9)23.0 (7)23.2 (7)––– 2024T-75 3⁄4 (1.90) 24 (610) 8 (200) 3 (76.2) 3 1 12 (3.7)–7.3 (2.2)5.9 (1.8)14.7 (4.5)7.1 (2.1)– 175 (1205)175 (1205) 2036T-75 36 (914)3 2 18 (5.5)–21.5 (6.5)10.4 (3.1)21.8 (6.6)10.9 (3.3)– 2048T-75 48 (1219)4 3 23 (7)–30.5 (9.3)14.9 (4.5)29 (8.8)14.8 (4.5)– 2060T-75 60 (1524)4 4 29 (8.8)–39.5 (12)19.4 (4.5)36.1 (11)18.7 (5.6)– 2072T-75 72 (1828)4 4 32 (9.8)–48.5 (14.7)24.0 (7.3)43.2 (13.1)22.6 (6.8)– FLEXHEAD® STANDARD TALL ELBOW 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024ET-50 1⁄2 (1.27) 24 (610) 8 (200) 3 (76.2) 3 1 19 (5.8) 26.4 (8.0)6.8 (2)7.4 (2.2)––– 175 (1205)175 (1205) 2036ET-50 36 (914)3 2 23 (7.0)30.1 (9.2)11.8 (3.6)12.5 (3.8)––– 2048ET-50 48 (1219)4 3 27 (8.2)33.8 (10.3)16.9 (5.1)17.6 (5.3)––– 2060ET-50 60 (1524)4 4 32 (9.8)37.5 (11.4)21.9 (6.6)22.7 (6.9)––– 2072ET-50 72 (1828)4 4 35 (10.7)41.2 (12.5)27.0 (8.2)27.8 (8.4)––– 2024ET-75 3⁄4 (1.90) 24 (610) 8 (200) 3 (76.2) 3 1 18 (5.5)-8.8 (2.6)8.7 (2.6)14.7 (4.5)8.2 (2.5)– 175 (1205)175 (1205) 2036ET-75 36 (914)3 2 23 (7.0)–25.5 (7.7)14.2 (4.2)21.8 (6.6)13 (3.9)– 2048ET-75 48 (1219)4 3 23 (7.0)–32.9 (10)18.4 (5.6)29 (8.8)17.8 (5.4)– 2060ET-75 60 (1524)4 4 29 (8.8)–40.6 (12.3)22.7 (6.9)36.1 (11.0)22.6 (6.8)– 2072ET-75 72 (1828)4 4 32 (9.8)–48.5 (14.7)27.0 (8.2)43.2 (13.1)27.5 (8.3)– FLEXHEAD® HIGH PRESSURE 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024H-50 1⁄2 (1.27) 24 (610) 8 (200) 3 (76.2) 3 2 11 (3.4) 18.4 (5.6)7.7 (2.3)7.6 (2.3)––– 300(2068)300(2068) 2036H-50 36 (914)3 3 16 (4.9)26.6 (8.1)11.5 (3.5)11.5 (3.5)––– 2048H-50 48 (1219)4 4 24 (7.3)30.3 (9.2)15.3 (4.6)15.4 (4.7)––– 2060H-50 60 (1524)4 4 29 (8.8)35.8 (10.9)19.1 (5.8)19.3 (5.8)––– 2072H50 72 (1828)4 4 35 (10.7)45.6(12.5)23.0 (7)23.2 (7)––– 2024ET-75 3⁄4 (1.90) 24 (610) 8 (200) 3 (76.2) 3 1 12 (3.7)-14.7 (4.5)6.8 (2.0)14.7 (4.5)8.2 (2.1)– 300(2068)300(2068) 2036ET-75 36 (914)3 2 18 (5.5)–21.5 (6.5)11.4 (3.4)21.8 (6.6)10.9 (3.3)– 2048ET-75 48 (1219)4 3 23 (7.0)–30.5 (9.2)16.0 (5.1)29 (8.8)14.8 (4.5)– 2060ET-75 60 (1524)4 4 29 (8.8)–39.5 (12)20.6 (6.2)36.1 (11.0)18.7 (5.7)– 2072ET-75 72 (1828)4 4 32 (9.8)–48.5 (14.7)25.3 (7.7)43.2 (13.1)22.6 (6.5)– BUILDING CONNECTIONS THAT LAST 11 FRICTION LOSS DATA & SPECIFICATIONS (CONT’D) Notes: Model Numbers: • “SF” designates SuperFlex® Hose series. • “ESF” designates SuperFlex® Elbow Hose series. • “E” designates elbow drop hose series • ”T” designates straight tall style hose • “ET” designates elbow tall style hose series. • “H” designates high pressure 300psi working pressure hose series. • “HE” designates high pressure 300psi elbow hose series. • “DPS” designates dry pendant system. • “DT” designates drain tee hose series used in dry pendent/freezer application. • “SLT” designates SlideLOK® technology. • “DPS” and “DT” models are approved for use in cold storage application (Freezer, Cold Chamber) and combine an approved flexible sprinkler hose and an approved dry pendent sprinkler. UHO-1 or UHO-3 is required to connect the flexible sprinkler hose to the dry sprinkler. • “I” indicates instiutional flexible hose. • “A” indicates models for use with Amerlux Ceiling System. • “50” designates 1⁄2" Outlet Hose series. The “75” designates 3⁄4” Outlet Hose series. Inlet size 1”. • Max Ambient Temperature Rating on all model numbers are 300˚ F (148˚ C). • Equivalent lengths are shown with maximum number of 90˚ bends at the minimum bend radius per agency. 2-45˚ or 3-30˚ bend equal 1-90˚ bend. Different values were obtained by FM and UL due to the difference in minimum bend radius, testing protocol and calculation methods. Please see individual standards for more information relative to Friction Loss (equivalent length of pipe). • All hoses require a minimum of one bend for installation. Bend radius tool available for 3” bend “T” hose, “SF” hose does not require bend radius tool. • FM equivalent length calculation includes Sprinkler Head Friction Loss. • See listing(s) approval agency for the latest approval details. • Friction loss data and specification of SuperFlex series include all end connection such as 1” NPT, 1” cut groove, and SLT. Specify end connection when ordering. Model Number Outlet Orifice Size Hose Assembly Length Minimum Bend Radius Maximum Number of 90˚ Bends Equivalent Length of 1in. Diameter Schedule 40 Pipe (Ft)Max Rated Pressure FM UL UL FM UL FM FM LU5.6k-factor 8.0k-factor 11.2k-factor 14.0k-factor 16.8k-factor 22.4k-factor in (cm)in (mm)in (mm)in (mm)in (mm)in (mm)Ft (mm)Ft (mm)Ft (mm)Ft (mm)Ft (mm)Ft (mm)Ft (mm)PSI/Kpa PSI/Kpa FLEXHEAD® HIGH PRESSURE ELBOW 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024HE-50 1⁄2 (1.27) 24 (610) 8 (200) 3 (76.3) 3 2 19 (5.8)14.7 (4.5)6.8 (2)7.4 (2.2)––– 300 (2068)300 (2068) 2036HE-50 36 (914)3 3 23 (7.0)21.8 (6.6)11.8 (3.6)12.5 (3.8)––– 2048HE-50 48 (1219)4 4 27 (8.2)29.0 (8.8)16.9 (5.1)17.6 (5.3)––– 2060HE-50 60 (1524)4 4 32 (9.8)36.1 (11)21.9 (6.6)22.7 (6.9)––– 2072HE-50 72 (1828)4 4 35 (10.7)43.2 (13.1)27.0 (8.2)27.8 (8.4)––– 2024HE-75 3⁄4 (1.90) 24 (610) 8 (200) 3 (76.3) 3 2 18 (5.5)-14.7 (4.5)-14.7 (4.5)8.2 (4.5)– 300 (2068)300 (2068) 2036HE-75 36 (914)3 3 23 (7.0)-25.2 (7.7)26 (7.9)21.8 (8.6)13 (3.9) – 2048HE-75 48 (1219)4 4 23 (7.0)–32.9 (10)33 (10)29 (8.8)17.8 (5.4)– 2060HE-75 60 (1524)4 4 29 (8.8)-40.5 (12.3)40 (12.2)36.1 (11.0)22.6 (6.8)- 2072HE-75 72 (1828)4 4 32 (9.8)-48.5 (14.8)47 (14.3)43.2 (13.1)27.5 (8.3)- FLEXHEAD® DRY PENDENT SYSTEM 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024-DPS 1(2.54) 24 (610) 7 (200) - -1 -18.4 (5.6)7.7 (2.3)7.6 (2.3)–7.1 (2.1)10.7 (3.3) -175 (1205) 2036-DPS 36 (914)-2 -26.6 (8.1)11.5 (3.5)11.5 (3.5)–10.9 (3.3)15.1 (4.6) 2048-DPS 48 (1219)-3 -30.3 (9.2)15.3 (4.7)15.4 (4.7)–14.8 (4.5)21.5 (6.5) 2060-DPS 60 (1524)-4 -35.8 (10.9)19.1 (5.8)19.3 (5.9)–18.7 (5.7)25.3 (7.7) 2072-DPS 72 (1828)-4 -45.6 (13.9)23.0 (7)32.2 (7)–22.6 (6.9)26.9 (8.1) FLEXHEAD® INSTITUTIONAL 1" INTERNAL DIAMETER (I.D.) HOSE SERIES 2024I 1⁄2 (1.27) 24 (610) 8 (200) 3 (76.2) 3 1 11 (3.4) 18.4 (5.6)––––– 175 (1205)175 (1205) 2036I 36 (914)3 3 16 (4.9)26.6 (8.1)––––– 2048I 48 (1219)4 4 24 (7.3)30.3 (9.2)––––– 2060I 60 (1524)4 4 29 (8.8)35.8 (10.9)––––– 2072ET-50 72 (1828)4 4 35 (10.7)45.6 (13.9)––––– 2024I 3⁄4 (1.90) 24 (610) 8 (200) 3 (76.2) 3 1 12 (3.7)-––11.6 (3.5)–– 175 (1205)175 (1205) 2036I 36 (914)3 2 18 (5.5)–––16 (4.9)–– 2048I 48 (1219)4 3 23 (7.0)–––17.9 (5.4)–– 2060I 60 (1524)4 4 29 (8.8)–––24.7 (7.5)–– 2072I 72 (1828)4 4 32 (9.8)–––28.9 (8.8)–– FLEXHEAD® 12 Each FM approved and UL listed unit is ready to install, pressure- and leak-tested, and comes complete with a flexible stainless steel hose and mounting bracket with adjustable hub. FLEXHEAD® STANDARD HOSE 3" BEND RADIUS PER UL GUIDELINES (2 BENDS SHOWN)*FLEXHEAD® STANDARD HOSE SHOWN WITH 3 BENDS SUSPENDED CEILING DETAIL GYPSUM BOARD HARD CEILING DETAIL 1 2 * Notes: SuperFlex® has a 2" bend radius. For more information on SuperFlex® specification refer to page 10. *Allows for bracket installation without pre-installing the ceiling tile MPO24BKT2 Bracket MPO24BKT2, ADO24BKT3 & ADO16BKT3 Brackets MPT24BKT1 Bracket MPT24BKT1 Bracket FLEXHEAD® CEILING DETAIL BUILDING CONNECTIONS THAT LAST 13 MODEL #“Hose Assembly (L) Length Inches (mm)”“Drop “”D”” Size (Inches)” 2024E/2024HE 24 (610) 1.5, 3.0, & 4.0 2036E/2036HE 36 (914) 2048E/2048HE 48 (1219) 2060E/2060HE 60 (1524) 2072E/2072HE 72 (1828) 2024ET 24 (610) 5.71 2036ET 36 (914) 2048ET 48 (1219) 2060ET 60 (1524) 2072ET 72 (1828) FLEXHEAD® CEILING DETAIL 1.0" 1.5" 2.0" 2.5" 3.0" 3.5" 4.0" 4.5" 5.0" 5.5" REGULAR 1" HOSE MODEL20XXSF & 20XXT SERIES 1" NPT CUT GROOVE OPTION WITH 20XXSF ½" NPT OR 3/4"NPT FEMALE THREAD ½" NPT OR 3/4"NPT FEMALE THREAD ½" NPT, 3/4" OR 1" NPT FEMALE THREAD Ø 1.315 in Ø 1.315 in Ø 1.315 in 2.25 in"D"SEE CHART Ø 1.315 in 1.5 in 1.5 in 1" NPT 1" NPT3 in 3 in 3 in3 in REGULAR 1" HOSE MODEL20XXH SERIES ELBOW 1" HOSE MODEL20XXE, 20XXHE & 20XXET SERIES STANDARD- 1 1/4" HOSE MODEL20XXF SERIES 6.3 in 4.50 in L ±20mm L ±20mm L ±20mm L ±20mm 1" NPT THREAD OR 1 ¼" CUT GROOVE OPTION AVAILABLE FLEXHEAD® 14 MODEL MPO24BKT2 MODEL MPT24BKT1 MODEL AD016BKT3, AD024BKT3, AD030BKT3, & AD048BKT3 BRACKET SPECIFICATION SHEET Multiport Design (For use with T-bar and Metal Stud Applications) Multi-Position Tall Bracket (For use with T-bar, Wood and Metal Studs): 24" standard size collapsible to 14.5" and 16" long. Adjustable Design (For use with T-bar, Metal Stud and Chicago Grid Applications): standard sizes are 16", 24", 30" and 48" long 14.5 in [ 368.3 mm ] 16 in [ 406 mm ] 24in [609 mm ] BUILDING CONNECTIONS THAT LAST 15 24", 36", 48", 60", and 72" hose lengths, Rated working pressure 175psi, optional 300psi. Standard 1" I.D., optional 11⁄4" I.D. 24" Multiport Bracket for T-bar Grid or Metal Stud applications. 6" stable mounting bracket. Hat Channel Bracket System for Metal Stud or Hat Channel applications. Designed for quick and easy installation. Ideal for shell applications. Can be installed with 3/8" threaded rod up to 4' off structure and with 1/2" threaded rod up to 6' off structure. Armstrong® TechZone Ceiling Bracket for use with Armstrong TechZone Ceiling systems. Available in 6" widths. Dry Pendent System for Freezer and Cold Storage applications 24", 36", 48", 60", and 72" hose lengths. Rated working pressure 175psi, optional 300psi. 16", 24", 30", 48" Adjustable Bracket for T-bar Grid, Chicago Grid or Metal Stud applications. 24" Multi-Position Tall Bracket, collapses to 14 1/2" and 16". Installs in suspended ceilings without touching the ceiling tiles. STANDARD FLEXHEAD® HOSE LENGTHS: 24", 36", 48", 60" AND 72" MODEL MP024BKT2 SUPERFLEX® HOSE LENGTHS: 36", 48", AND 72" MODEL ADO24BKT3 WITH BKT-HTA MODEL UHO-3 MODEL SP06TZBKT2 MODEL 20XX-DPS-UHO-3 MODELS AD016BKT3, AD024BKT3, AD030BKT3 & ADO48BKT3 MODEL MPT24BKT1 FLEXHEAD® COMMERCIAL PRODUCTS STRAIGHT MODEL ELBOW MODEL FLEXHEAD® 16 FLEXIBLE SPRINKLER HOSE FITTINGS FOR FIRE PROTECTION SERVICE A. Manufacturer: FlexHead; Brand of Anvil International B. Contact: 160 Frenchtown Rd, North Kingstown RI 02852 ; Telephone: (800) 829-6975; Email: FlexHeadsales@anvilintl.com; website: www.flexhead.com & www.anvilintl.com 1. Substitutions: No substitutions allowed. C. Description: 1. Regulatory Requirements: Provide flexible stainless steel hose fittings that comply with the following requirements: a. In accordance with General Requirements contained in Division 1 of specification. b. In accordance with NFPA 13. D. Performance Criteria: Comply with the following to suit project requirements: 1. 1. FM 1637 Approval Standard for Flexible Sprinkler Hose with Threaded End Fittings. 2. 2. UL 2443 Standard for Flexible Sprinkler Hose with Fittings for Fire Protection Service 3. 3. ICC-ES AC-156 Acceptance Criteria for Seismic Qualification by Shake-Table Testing of Nonstructural Components and Systems E. Materials: FlexHead Commercial Sprinkler Connections 1. FlexHead flexible stainless steel hose assemblies: a. Straight Hose Assembly Lengths: {2ft length, Model #2024T, 2024SF} {3ft length, Model #2036T, 2036SF} {4ft length, Model #2048T, 2048SF} {5ft length, Model #2060T, 2060SF} {6ft length, Model #2072T, 2072SF}.} 1. {½ inch} {3/4 inch} outlet. 2. {175 psi} {300 psi} maximum rated pressure. 3. Fully welded non-mechanical fittings, braided, 100% leak-tested, with a minimum 1 inch true-bore internal corrugated hose diameter made of 100% 304 stainless steel braid, hose and end fittings. 1” NPT, 1” cut groove, or SLT end connection with 74FP SlideLOK®. b. Elbow Hose Assembly Lengths (For use in confined spaces): {2ft length, Model #2024E, 2024ET} {3ft length, Model #2036E, 2036ET} { 4ft length, Model #2048E, 2048ET} {5ft length, Model #2060E, 2060ET} { 6ft length, Model #2072E, 2072ET} 1. {½ inch} {3/4 inch} outlet. 2. {175 psi} {300psi} maximum rated pressure. 3. Fully welded non-mechanical fittings, braided, leak-tested with minimum 1 inch true-bore internal corrugated hose diameter made of 100% 304 stainless steel including end fittings. 2. FlexHead Ceiling Bracket: Direct attachment type having integrated ends positively attached to the ceiling using screws and attachment hub with set screw for attaching and adjusting flexible hose. FLEXHEAD® STANDARD SPECIFICATIONS DIVISION 21 MECHANICAL – SECTION 15300 FIRE PROTECTION PIPING BUILDING CONNECTIONS THAT LAST APPLICABLE STANDARDS American Society of Civil Engineers (ASCE) -SEI/ASCE 7-05, Section 13.5.6 Suspended Ceilings ASTM INTERNATIONAL •ASTM C635 Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings •ASTM C636 Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels •FM Global Technologies LLC (FM) - FM Class Number 1637 Approval Standard for Flexible Sprinkler Hose with Threaded End Fittings INTERNATIONAL CODE COUNCIL (ICC) • ICC International Building Code (IBC), 2006 - Section 803.9 Acoustical Ceiling Systems - Section 1613 Earthquake Loads NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) •NFPA 13 Standard for the Installation of Sprinkler Systems •NFPA 13D Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes •NFPA 13R Standard for the Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height Underwriters Laboratories, Inc. (UL) - UL 2443 Standard for Flexible Sprinkler Hose with Fittings for Fire Protection Service APPROVALS Underwriters Laboratories, Inc. (UL) - UL Listed, VENF. EX5269, Flexible Sprinkler Hose Fitting PHYSICAL/CHEMICAL PROPERTIES Test reports are available to design professionals upon request. PREPARATORY WORK Installation should only be performed by qualified and licensed technicians in the fire protection field. Consult NFPA, FM, UL and state and local guidelines prior to installation. METHODS Each FlexHead ceiling sprinkler connection includes a mounting bracket and a 1-piece, leak tested FlexHead sprinkler drop. Attach the bracket to the t-bar ceiling grid; then attach the FlexHead sprinkler to the sub-main. Secure the sprinkler to the bracket. Test installation of sprinkler system for any leaks per NFPA guidelines. BUILDING CODES Current data on building code requirements and product compliance may be obtained from the manufacturer’s tech- nical support specialists. Installation must comply with the requirements of applicable local, state and national code jurisdictions. COST Budget installed cost information may be obtained from the manufacturer upon request. MAINTENANCE Contact the manufacturer for complete maintenance information. TECHNICAL SERVICES Design assistance and technical support are available upon request from the manufacturer’s trained staff. FILING SYSTEMS • MANU-SPEC® • Additional product information is available from the manufacturer upon request PRECAUTIONS Consult the manufacturer’s installation instructions for complete installation information. Failure to follow the cited instructions may cause personal injury. During maintenance or inspection of FlexHead product, the facility fire protection system must be inactive. Do not attempt relocation or maintenance of FlexHead product while fire protections system is live. DISCLAIMER •It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. •Failure to follow these instructions could causeproduct failure, resulting in serious personal injury and/or property damage. 17 FLEXHEAD® 18 BRANDS OF ANVIL INTERNATIONAL Anvil product lines include malleable and cast iron fittings, unions and flanges; seamless and welded steel pipe nipples; steel pipe couplings; universal anvilets; forged steel fittings and unions; pipe hangers and supports; threaded rod; and engineered hangers Anvil-Strut products include a complete line of channel in stock lengths of 10 and 20 feet, with custom lengths available upon request. A variety of fittings and accessories are also offered. All products can be ordered in an assortment of finishes and material choices including SupR-GreenTM, Zinc Trivalent Chromium, pre- galvanized, hot-dipped galvanized, electro-galvanized, aluminum, plain, and stainless steel. Catawissa hammer unions are offered in threaded ends and butt weld ends, and are interchangeable with most leading union manufacturers. Fully traceable and available with complete mill certifications, Catawissa’s oilfield hammer union product line includes the standard ball-and-cone design plus our unique Figure 300 Flat Face design, where space and pipe line separation are a consideration. The AnvilPress™ Technology for Copper Systems and Stainless Steel Systems includes couplings, elbows, tees, adapters, fitting reducers, caps, unions, and flanges for mechanical copper systems. They provide an economical and reliable piping connection that can be used for commercial, industrial, and residential markets. Fittings are available in sizes 1/2" to 4". Copper fittings can be easily identified with a visual inspection of the patented green indicator band extruded at each joint. The SPF/Anvil product line includes a variety of internationally sourced products such as grooved couplings, fittings, cast iron, malleable iron and ductile iron threaded fittings, steel pipe nipples, as well as tee-lets. The Merit product line includes a variety of tee-lets and drop nipples for fire protection applications. Most Merit products are UL/ ULC Listed, FM Approved, and rated from 175 to 300 psi. Anvil EPS-Engineered Pipe Supports are products used to support piping systems under thermal, seismic, and other dynamic loading conditions. The product line encompasses variable spring hangers, constant supports, sway struts and snubbers as well as standard and special design clamps. Anvil EPS brings the highest quality products and innovative engineering solutions to common and uncommon piping system problems. BUILDING CONNECTIONS THAT LAST 19 The Afcon seismic bracing line includes UL listed and FM approved structural attachments for concrete, wood or steel structural members like bar joist or I-beams, swivel connections that accept from 1" to 2" schedule 40 pipe. Afcon’s seismic system attachments are engineered for up to 12" IPS steel pipe, copper tubing or plastic pipe. North Alabama Pipe Founded in 1983, NAP is a manufacturer of fabrication equipment, including automatic welders, plasma cut-off equipment, hole cutting equipment, make-on machines and pipe threaders. NAP, innovators of pipe fabrication equipment. The Gruvlok product line consists of couplings for grooved and plain-end fittings, butterfly valves and check valves; flanges; pump protection components; pipe grooving tools; as well as copper and stainless steel system components. JB Smith is the leading manufacturer of oil country tubular fittings, swages and bull plugs – all meeting API specifications. Offering tubing nipples, casing nipples as well as a full line of traditional line pipe and oil country threads in every schedule, JB Smith is the resource for all your oilfield needs. We invented the concept of Flexible Fire Protection™. FlexHead systems connect sprinkler heads to sub-mains at least four times faster than hard pipe. Delivers even greater savings in retrofits. All our flexible sprinkler pipe and connections are UL Listed and/or FM Approved. The SprinkFLEX® product line includes a variety of hoses and brackets offering a cost effective solution for the installation of fire sprinkler systems which result in a quick and easy way to connect the sprinkler heads to the branch lines. All hoses and brackets are UL and/or FM Approved. Steel pipe nipples and steel pipe couplings are manufactured in accordance with the ASTM A733 Standard Specification for Welded and Seamless Carbon Steel and Stainless Steel Pipe Nipples. Steel pipe couplings are manufactured in accordance with the ASTM A865 Standard Specification for Threaded Couplings, Steel, Black or Zinc-Coated (Galvanized) Welded or Seamless, for Use in Steel Pipe Joints. API couplings are manufactured in accordance with the API Specification for line pipe. Guntersville, AL Irving, TX Henderson, TN Tinley Park, IL Waynesboro, PAGreencastle, PA Johnstown, PA Columbia, PASomerset, NJ North Kingstown, RISimcoe, ON, Canada Exeter, NH Orlando, FLHouston, TX Ontario, CA 20 REGIONAL DISTRIBUTION CENTERS UNITED STATES TEL: 800-301-2701 FAX: 708-534-5441 EMAIL: customerservice@anvilintl.com CANADA TEL: 800-661-8998 FAX: 519-426-5509 EMAIL: canadacs@anvilintl.com LATIN AMERICA TEL: +1-800-885-3000 FAX: +1-708-534-5441 EMAIL: latinoamerica@anvilintl.com INTERNATIONAL TEL: +31-53-572-5570 EMAIL: internationalsales@anvilintl.com UNITED STATES ILLINOIS 7979 W. 183rd Street, Unit D Tinley Park, IL 60484 TEXAS 1401 Valley View Lane, Suite 150 Irving, TX 75061 PENNSYLVANIA 800 Malleable Road Columbia, PA 17512 CALIFORNIA 551 North Loop Drive Ontario, CA 91761 FLORIDA 236 Outlook Point Drive, Suite 100 Orlando, FL 32809 CANADA ONTARIO 390 Second Avenue, P.O. Box 40 Simcoe Ontario, Canada N3Y 4K9 CUSTOMER SERVICE CENTERS Corporate Headquarters Plants Regional Distribution Centers Guntersville, AL Irving, TX Henderson, TN Tinley Park, IL Waynesboro, PAGreencastle, PA Johnstown, PA Columbia, PASomerset, NJ North Kingstown, RISimcoe, ON, Canada Exeter, NH Orlando, FLHouston, TX Ontario, CA ANVIL MAINTAINS CONTRACTS WITH A CORE FLEET OF CARRIERS TO PROVIDE EFFICIENTLY CONSISTENT DELIVERY SERVICES TO OUR CLIENTS. www.anvilintl.com ©2019 Anvil International. Anvil, Gruvlok, Merit, SPF Anvil, SlideLOK, FlexHead, SuperFlex, Afcon, Seisbrace, Anvil-Strut are registered trademarks of Anvil International, LLC. All Rights Reserved.ANV_BRO_FP_190625 PROJECT: ENGINEER: LOCATIONS: CONTRACTOR: SPECIFICATION REFERENCE: DATE: SYSTEM TYPE: COMMENTS: SUBMITTAL INFORMATION FM Approved and Fully Listed Sprinkler Pipe Wheatland Tube’s Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL® and C-UL Listed. Approvals and Specifications Schedule 10 and Schedule 40 meet or exceed the following standards: • ASTM A135, Type E, Grade A (Schedule 10, 1–8 NPS) • ASTM A795, Type E, Grade A (Schedule 40, 1–2 NPS) • ASTM A53, Type E, Grade B (Schedule 40, 2–8 NPS) • ASTM A53, Type F, Grade A (Schedule 40, 1–4 NPS) • NFPA® 13 and NFPA 14 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black or hot-dip galvanized, to meet FM / UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Bar coding is acceptable as a supplementary identification method. Fire Sprinkler Pipe Schedule 10 and Schedule 40 Submittal Data Sheet BLACK HOT-DIP GALVANIZED info@wheatland.com wheatland.com Follow us on Twitter: @WheatlandTube 700 South Dock Street Sharon, PA 16146 P 800.257.8182 F 724.346.7260 Fire Sprinkler Pipe Schedule 10 and Schedule 40 Submittal Data Sheet info@wheatland.com wheatland.com Follow us on Twitter: @WheatlandTube 700 South Dock Street Sharon, PA 16146 P 800.257.8182 F 724.346.7260 WFS-081619 SCHEDULE 10 WEIGHTS AND DIMENSIONS NPS NOMINAL OD NOMINAL ID NOMINAL WALL WT. / FT.WT. / FT. H2O FILLED PCS. / LIFT WT. / LIFT 21'WT. / LIFT 24'WT. / LIFT 25'UL in.mm in.mm in.mm lbs.lbs.lbs.lbs.lbs.CRR* 1 1.315 33.4 1.097 27.9 0.109 2.77 1.405 1.814 70 2065 2360 2459 11.4 1 1/4 1.660 42.2 1.442 36.6 0.109 2.77 1.807 2.514 61 2315 2645 2756 7.3 1 1/2 1.900 48.3 1.682 42.7 0.109 2.77 2.087 3.049 61 2673 3055 3183 5.8 2 2.375 60.3 2.157 54.8 0.109 2.77 2.640 4.222 37 2051 2344 2442 4.7 2 1/2 2.875 73.0 2.635 66.9 0.120 3.05 3.354 5.895 30 2226 2544 2651 3.5 3 3.500 88.9 3.260 82.8 0.120 3.05 4.336 7.949 19 1730 1977 2060 2.6 4 4.500 114.3 4.260 108.2 0.120 3.05 5.619 11.789 19 2242 2562 2669 1.6 5 5.563 141.3 5.295 134.5 0.134 3.40 7.780 17.309 13 2124 2427 2529 1.5 6 6.625 168.3 6.357 161.5 0.134 3.40 9.298 23.038 10 1953 2232 2325 1.0 8 8.625 219.1 8.249 209.5 0.188 4.78 16.960 40.086 7 2493 2849 2968 2.1 SCHEDULE 40 WEIGHTS AND DIMENSIONS NPS NOMINAL OD NOMINAL ID NOMINAL WALL WT. / FT.WT. / FT. H2O FILLED PCS. / LIFT WT. / LIFT 21'WT. / LIFT 24'WT. / LIFT 25'UL in.mm in.mm in.mm lbs.lbs.lbs.lbs.lbs.CRR* 1 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.055 70 2470 2822 2940 1.000 1 1/4 1.660 42.2 1.380 35.1 0.140 3.56 2.27 2.922 51 2431 2778 2894 1.000 1 1/2 1.900 48.3 1.610 40.9 0.145 3.68 2.72 3.602 44 2513 2872 2992 1.000 2 2.375 60.3 2.067 52.5 0.154 3.91 3.66 5.109 24 1845 2108 2196 1.000 2 1/2 2.875 73.0 2.469 62.7 0.203 5.16 5.80 7.871 20 2436 2784 2900 1.000 3 3.500 88.9 3.068 77.9 0.216 5.49 7.58 10.783 13 2069 2365 2464 1.000 3 1/2 4.000 101.6 3.548 90.1 0.226 5.74 9.12 13.400 10 1915 2189 2280 1.000 4 4.500 114.3 4.026 102.3 0.237 6.02 10.80 16.311 10 2268 2592 2700 1.000 5 5.563 141.3 5.047 158.2 0.258 6.55 14.63 23.262 7 2151 2458 2560 1.000 6 6.625 168.3 6.065 154.1 0.280 7.11 18.99 31.498 5 1994 2279 2374 1.000 8**8.625 219.1 7.981 202.7 0.322 8.18 28.58 50.240 5 3001 3430 3573 1.000 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). ** 8 NPS Schedule 40 is FM Approved but not UL Listed. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3201 90˚ Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A A FIGURE 3201 - 90° ELBOW Nominal Size MaximumWorking Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 11⁄4 500 1.75 0.90 32 3450 44.45 0.41 11⁄2 500 1.94 1.20 40 3450 49.276 0.54 2 500 2.25 1.85 50 3450 57.15 0.84 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3202 45˚ Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A A FIGURE 3202 - 45° ELBOW Nominal Size MaximumWorking Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.12 0.46 25 3450 28.44 0.21 11⁄4 500 1.29 0.73 32 3450 32.76 0.33 11⁄2 500 1.43 0.92 40 3450 36.32 0.42 2 500 1.68 1.50 50 3450 42.67 0.68 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3201R Reducing 90˚ Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3201R - REDUCING 90° ELBOW Nominal Size Max. Working Pressures Dimensions Approx. Wt. Each1 x 2 A B In. (mm) PSI (kPa) In. (mm) In. (mm) Lbs. (kg) 1 x 1⁄2 500 1.26 1.36 0.44 25 x 15 3450 32.00 34.54 0.20 1 x 3⁄4 500 1.37 1.45 0.52 25 x 20 3450 34.79 36.83 0.24 11⁄4 x 1⁄2 500 1.34 1.53 0.64 32 x 15 34550 34.03 38.86 0.29 11⁄4 x 3⁄4 500 1.45 1.62 0.72 32 x 20 3450 36.83 41.14 0.33 11⁄4 x 1 500 1.58 1.67 0.75 32 x 25 3450 40.13 42.41 0.34 11⁄2 x 1 500 1.65 1.80 0.92 40 x 25 3450 41.91 45.72 0.42 11⁄2 x 11⁄4 500 1.82 1.88 1.08 40 x 32 3450 46.22 47.75 0.49 2 x 1⁄2 500 1.49 1.88 1.08 50 x 15 3450 37.84 47.75 0.49 2 x 3⁄4 500 1.60 1.97 1.24 50 x 20 3450 40.64 50.03 0.56 2 x 1 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 11⁄4 500 1.90 2.10 1.52 50 x 32 3450 48.26 53.34 0.70 2 x 11⁄2 500 2.02 2.16 1.65 50 x 40 3450 51.30 54.86 0.75 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. A B 2 1 1 x 2 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3205R Reducing Tee For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3205R - REDUCING TEE Nominal Size Max.WorkingPressures Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 x 1⁄2 x 1 500 1.50 1.36 1.50 0.6425 x 15 x 25 3450 38.10 34.54 38.10 0.29 1 x 3⁄4 x 1 500 1.50 1.45 1.50 0.73 25 x 20 x 25 3450 38.10 36.83 38.10 0.33 1 x 1 x 1⁄2 500 1.26 1.26 1.36 0.71 25 x 25 x 15 3450 32.00 32.00 34.54 0.32 1 x 1 x 3⁄4 500 1.37 1.37 1.45 0.76 25 x 25 x 20 3450 34.80 34.80 36.83 0.34 1 x 1 x 11⁄4* 500 1.67 1.67 1.58 0.98 25 x 25 x 32 3450 42.41 42.41 40.13 0.44 1 x 1 x 11⁄2* 500 1.80 1.80 1.65 1.16 25 x 25 x 40 3450 45.72 45.72 41.91 0.53 11⁄4 x 1 x 1⁄2* 500 1.34 1.26 1.53 0.82 32 x 25 x 15 3450 34.04 32.00 38.86 0.37 11⁄4 x 1 x 3⁄4 500 1.45 1.37 1.62 0.90 32 x 25 x 20 3450 36.83 34.80 41.15 0.41 11⁄4 x 1 x 1 500 1.58 1.50 1.67 1.0032 x 25 x 25 3450 40.13 38.10 42.42 0.45 11⁄4 x 1 x 11⁄4 500 1.75 1.67 1.75 1.08 32 x 25 x 32 3450 44.45 42.42 44.45 0.49 11⁄4 x 1 x 11⁄2 500 1.88 1.80 1.82 1.42 32 x 25 x 40 3450 47.75 45.72 46.22 0.64 11⁄4 x 11⁄4 x 1⁄2 500 1.34 1.34 1.53 0.86 32 x 32 x 15 3450 34.04 34.04 38.86 0.39 FIGURE 3205R - REDUCING TEE Nominal Size Max.WorkingPressures Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 11⁄4 x 11⁄4 x 3⁄4 500 1.45 1.45 1.62 0.92 32 x 32 x 20 3450 36.83 36.83 41.15 0.42 11⁄4 x 11⁄4 x 1 500 1.58 1.58 1.67 0.9532 x 32 x 25 3450 40.13 40.13 42.42 0.43 11⁄4 x 11⁄4 x 11⁄2* 500 1.88 1.88 1.82 1.4532 x 32 x 40 3450 47.75 47.75 46.22 0.66 C A B 3 1 1 x 2 x 3 2 s Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3205R Reducing Tee FIGURE 3205R - REDUCING TEE Nominal Size Max.WorkingPressures Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs. (kg) 11⁄2 x 11⁄2 x 2*500 2.16 2.16 2.02 1.98 40 x 40 x 50 3450 54.86 54.86 51.30 0.90 2 x 1 x 2 500 2.25 2.02 2.25 2.15 50 x 25 x 50 3450 57.15 51.31 57.15 0.98 2 x 11⁄4 x 2 500 2.25 2.10 2.25 2.30 50 x 32 x 50 3450 57.15 53.34 57.15 1.04 2 x 11⁄2 x 1⁄2 500 1.49 1.41 1.88 1.50 50 x 40 x 15 3450 37.85 35.81 47.75 0.68 2 x 11⁄2 x 3⁄4 500 1.60 1.52 1.97 1.62 50 x 40 x 20 3450 40.64 38.61 50.04 0.73 2 x 11⁄2 x 1 500 1.73 1.65 2.02 1.64 50 x 40 x 25 3450 43.94 41.91 51.31 0.74 2 x 11⁄2 x 11⁄4 500 1.90 1.82 2.10 1.80 50 x 40 x 32 3450 48.26 46.23 53.34 0.82 2 x 11⁄2 x 11⁄2 500 2.02 1.94 2.16 2.00 50 x 40 x 40 3450 51.31 49.28 54.86 0.91 2 x 11⁄2 x 2 500 2.25 2.16 2.25 2.35 50 x 40 x 50 3450 57.15 54.86 57.15 1.07 2 x 2 x 1⁄2 500 1.49 1.49 1.88 1.60 50 x 50 x 15 3450 37.85 37.85 47.75 0.73 2 x 2 x 3⁄4 500 1.60 1.60 1.97 1.68 50 x 50 x 20 3450 40.64 40.64 50.04 0.76 2 x 2 x 1 500 1.73 1.73 2.02 1.85 50 x 50 x 25 3450 43.94 43.94 51.31 0.84 2 x 2 x 11⁄4 500 1.90 1.90 2.10 2.04 50 x 50 x 32 3450 44.45 42.42 44.45 0.93 2 x 2 x 11⁄2 500 2.02 2.02 2.16 2.18 50 x 50 x 40 3450 44.45 42.42 44.45 0.99 FIGURE 3205R - REDUCING TEE Nominal Size Max.WorkingPressures Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm)PSI (kPa)In. (mm)In. (mm)In. (mm)Lbs. (kg) 11⁄4 x 11⁄4 x 2*500 2.10 2.10 1.90 1.75 32 x 32 x 50 3450 53.34 53.34 48.26 0.79 11⁄2 x 1 x 1⁄2 500 1.41 1.34 1.66 0.95 40 x 25 x 15 3450 35.81 34.04 42.16 0.43 11⁄2 x 1 x 3⁄4 500 1.52 1.37 1.75 1.14 40 x 25 x 20 3450 38.61 34.80 44.45 0.52 11⁄2 x 1 x 1 500 1.65 1.50 1.80 1.17 40 x 25 x 25 3450 41.91 38.10 45.72 0.53 11⁄2 x 1 x 11⁄4 500 1.82 1.67 1.88 1.34 40 x 25 x 32 3450 46.23 42.42 47.75 0.61 11⁄2 x 1 x 11⁄2 500 1.94 1.80 1.94 1.45 40 x 25 x 40 3450 49.28 45.72 49.28 0.66 11⁄2 x11⁄4 x 1⁄2 500 1.41 1.34 1.66 1.05 40 x 32 x 15 3450 35.81 34.04 42.16 0.48 11⁄2 x11⁄4 x 3⁄4 500 1.52 1.45 1.75 1.15 40 x 32 x 20 3450 38.61 36.83 44.45 0.5 11⁄2 x 11⁄4 x 1 500 1.65 1.58 1.80 1.25 40 x 32 x 25 3450 41.91 40.13 45.72 0.57 11⁄2 x 11⁄4 x 2*500 2.16 2.10 2.02 1.90 40 x 32 x 50 3450 54.86 53.34 51.30 0.86 11⁄2 x 11⁄2 x 1⁄2 500 1.41 1.41 1.16 1.15 40 x 40 x 15 3450 35.81 35.81 29.46 0.52 11⁄2 x 11⁄2 x 3⁄4 500 1.52 1.52 1.75 1.24 40 x 40 x 20 3450 38.61 38.61 44.45 0.56 11⁄2 x 11⁄2 x 1 500 1.65 1.65 1.80 1.30 40 x 40 x 25 3450 41.91 41.91 45.72 0.59 11⁄2 x 11⁄2 x 11⁄4 500 1.82 1.82 1.88 1.48 40 x 40 x 32 3450 46.23 46.23 47.75 0.67 C A B 3 1 1 x 2 x 3 2 s Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3205 Straight Tee For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A AA FIGURE 3205 - STRAIGHT TEE Nominal Size Maximum Working Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.50 0.85 25 3450 38.10 0.39 11⁄4 500 1.75 1.22 32 3450 44.45 0.55 11⁄2 500 1.94 1.55 40 3450 49.27 0.70 2 500 2.25 2.45 50 3450 57.15 1.11 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3221 Coupling For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3221 - COUPLING Nominal Size MaximumWorking Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.67 0.40 25 3450 42.42 0.18 11⁄4 500 1.93 0.57 32 3450 49.02 0.26 11⁄2 500 2.15 0.75 40 3450 54.61 0.34 2 500 2.53 1.15 50 3450 64.26 0.52 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-5.19 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3221R Reducing Coupling For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3221R - REDUCING COUPLING Nominal Size MaximumWorking Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 x 1⁄2 500 1.69 0.39 25 x 15 3450 42.92 0.18 1 x 3⁄4 500 1.69 0.53 25 x 20 3450 42.92 0.24 11⁄4 x 3⁄4 500 2.06 0.64 32 x 20 3450 52.32 0.29 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.14 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3283 Bushings For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3283 - BUSHINGS Nominal Size Max. WorkingPressures Dimensions Style Approx. Wt. EachMale (M) x Female (F)A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 x 1⁄2 500 0.75 0.25 1.42 Outside 0.22 25 x 15 3450 19.05 6.35 36.06 0.10 1 x 3⁄4 500 0.75 0.25 1.42 Outside 0.17 25 x 20 3450 19.05 6.35 36.06 0.08 11⁄4 x 1 500 0.80 0.28 1.76 Outside 0.28 32 x 25 3450 20.32 7.11 44.70 0.13 11⁄2 x 1 500 0.83 0.31 2.00 Outside 0.45 40 x 25 3450 21.08 7.874 50.80 0.20 11⁄2 x 11⁄4 500 0.83 0.31 2.00 Outside 0.30 40 x 32 3450 21.08 7.874 50.80 0.14 2 x 1 500 0.88 0.41 1.95 Inside 0.67 50 x 25 3450 22.35 10.414 49.53 0.30 2 x 11⁄4 500 0.88 0.34 2.48 Outside 0.73 50 x 32 3450 22.35 8.636 62.99 0.33 2 x 11⁄2 500 0.88 0.34 2.48 Outside 0.61 50 x 40 3450 22.35 8.636 62.99 0.28 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. A B C A B C Inside Head Outside Head A B C A B C Inside Head Outside Head M F M F A B C A B C Inside Head Outside Head A B C A B C Inside Head Outside Head M F M F PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3224 Cap For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3224 - CAP Nominal Size MaximumWorking Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1 500 1.16 0.32 25 3450 29.46 0.15 11⁄4 500 1.28 0.43 32 3450 32.51 0.20 11⁄2 500 1.33 0.60 40 3450 33.78 0.27 2 500 1.45 0.91 50 3450 36.83 0.41 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-5.16 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.14 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS s Pressure - Temperature Ratings in accordance with ASME B16.3 Class 150 FIG. 3388 Cored Plug For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3388 - CORED PLUG Nominal Size MaximumWorking Pressures Dimension A Approx. Wt. Each In. (mm)PSI (kPa)In. (mm)Lbs. (kg) 1⁄2*500 0.94 0.10 15 3450 23.87 0.05 3⁄4 500 1.07 0.17 20 3450 27.17 0.08 1 500 1.25 0.28 25 3450 31.75 0.13 11⁄4 500 1.36 0.44 32 3450 34.54 0.20 11⁄2 500 1.45 0.62 40 3450 36.83 0.28 2 500 1.56 0.91 50 3450 39.62 0.41 s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as Solid Plug.