Loading...
HomeMy WebLinkAboutR-436402SIERRA HOMES SFR Nt co co Nt i 0 LU I- LL U) LULU G O Q rr LU Know what's below. Call before you dig. NW 114 OF SW 114 OF SECTION 32, T. 24 N., R. 05 E., W.M. CITY OF RENTON, KING COUNTY, WASHINGTON 3342102560 1021 N 5TH ST TW=116.00 RENTON 98056 BW=114.00 - - - - - - - - - - - -�N89°08'15"W 110� 0� TW=116.00 BW=112.00 / / �� / / \ / 1 SHED I 142 ROOFLINE / (TYP) I 18. ' / 18.5' WEATHERDECK / Lr120.0 1 SDCO PER COR (SEE 25L-B-SBL STD 226.00 PROPOSED BLOCK WALL ARCHITECTURAL (TYP) (DESIGN BY OTHERS) a I PLAN) a IE=118.5' F_ LO o I I GRAPHIC SCALE G/ I I 10 0 5 10 ,c3 00 ° I / ���0 N SDCO IE = 117.5' I /I SCALE: 1" = 10' FOUNDATION LINE W/ 4" I ROOF DECK I I I f PERFORATED PVC FOOTING I DRAIN (TYP) I I 1 I I I I / I 56 LF 4" PVC I I ROOF DRAIN I 027. I 57 LF 4" PVC l ° I ROOF DRAIN I T.P.N. ® 29 PROPOSED 3342102710 v / / RESIDENCE 1012 N 34TH ST, MFF=121.50 RENTON, WA I l (SEE / a l ARCHITECTURAL o I 1 / PLAN) / 49 LF 4" PVC I yD ROOF DRAIN wI / 1 ®2q PROPOSED GARAGE I o CONNECT FOOTING FFE=120.00 `r L DRAIN SYSTEM TO _ z SDCO PER COR STD 226 (TIP) I 4" PVC I IE = 116.41 20.0' 120.0, of I al SDCO I CONNECT ROOF DRAIN SYSTEM TO 6" PERFORATED PVC AT CLEANOUT l IE = 117 32' IE = 116.4t I I / a �I� DISPERSION TW=118.00 I / SD 4 SD o I al TRANSITION STRIP BW=114.00 ENTRY . a . �- I� PER COR 263.20 I 20' BSBL I I 2' WIDE x 4" THICK 18 LF 6" PERFORATED PVC . II STUB -OUT CONNECTION a 119.90 11 11 12" APL y PER COR 263.4 a o / 26 15 LF 4" PVC FOOTING DRAIN BYPASS N a 2 0% a I I I 0 2.0% MIN, CONNECT DOWNSTREAM OF TRENCH PER COR 263.4 I I Q al 1 0 00' 3 I / SSCO PER COR STD 403.1 & 406.2 / a II I RIM=120.1t / N VEGETATED ?� pa I I IE=115.0t / \I' W PATH `I' a9 �tia al II SDCO (TYP) PER COR STD 226.0 PROPOSED GAS EX IE (SW) 4" PVC=116.0t I SERVICE LINE IE (E,FOOT) 4" PVC=116.Ot - TW 117.00 N 10 ° IE (E,ROOF) 6" PERE PVC=116:4 BW=116.00 117.40' N89°0 5'� w 5 4 20.50;�1� 1 20.81' a INSTALL JOINT TRENCH WITH A CONDUIT FOR FUTURE / _ N 9°04'15"W 1 .07' a:.�- a a PROPOSED SIDEWALK UNOERGROUNDING OF �/ 4" PVC N - - - - - - 1 - - a- �I r 2046' RECORD DRAWING NOTE THIS RECORD DRAWING HAS BEEN PREPARED BY G2 CIVIL. THE INFORMATION PRESENTED HEREON IS BASED UPON A COMBINATION OF APPROVED DESIGN PLAN INFORMATION, CONTRACTOR FIELD DRAWINGS PREPARED DURING THE COURSE OF CONSTRUCTION, AS -BUILT FIELD SURVEY INFORMATION GATHERED BY THE PROJECT LICENSED SURVEYOR OVER THE COURSE OF THE PROJECT CONSTRUCTION AND / OR OTHER RECORD INFORMATION PROVIDED BY OTHERS. THIS RECORD DRAWING REPRESENTS ACCURATE AS -BUILT CONDITIONS TO THE BEST KNOWLEDGE OF THE ENGINEER OF RECORD AND WAS PREPARED SOLELY TO FULFILL THE REQUIREMENTS OF AND SOLELY FOR THE USE BY THE CITY OF RENTON. ANY OTHER USER OF THIS RECORD DRAWING ASSUMES COMPLETE RESPONSIBILITY TO FIELD VERIFY ACTUAL FIELD LOCATIONS AND CONDITIONS AND IS HEREBY ADVISED TO DO SO. - - -_ _. - PER COR-STD 102 FRANCHISE UTILITIES STORMWATER STUB - - - Q APPROX. LOCATION 1 7.33' O / 19.07 120.43' T I 2p•7 ' CONTRACTOR TO WM P P P / PER COR AS-BUILTS N / a II PROTECT EX. SAN l �- P P - I I a SERVICE TO / - - - - - - - - - - 3' WIDE ASPr ALT F' - P P P P ' I P NFIGHBORI�G PROPERT�f s _ r- SD SD Sp PEDESTRIAN RAMP TYP 9 a. P P P - NOTE. 71E SIDEWALK AND / . . . . . . . . . . j ! 116.78 I D '�_ - SD CONCRETE CURB TO ADJACENT y `� 18.52' 119.88' I I 2 .5T y - t:r7 PROPERTY AT PROPERTY LINE IF . . . . . . . . . R ACE EX SDCB . L - - - - - - - - - - - - - I I - I . - . PROPOSED UNDERGROUND . . . . . y NEIGHBORING IMPROVEMENTS BY . . . . . . . . . . . . . i i i . . POWER SERVICE LINE TYPE 1 CB W/ I. I BOSSING INSTALL 39 LF 0 / SEPARATE PERMIT HAVE BEEN ^� OPEN GRATE �"-� W I I PROVIDE 1' VIER 1 " n�a 4 g . . . / COMPLETED; ASPHALT RAMP WILL .T ../I �' i. . . . L-j SEPARATION OR . . . . . . I . -2 9 W PER CORDSTDR101 / - W W W W NOT BE NEEDED IF ADJACENT RIM=1}E3f 117.11 CROSSING / - W -� W - IMPROVEMENTS ARE COMPLETED - - SDIE=115.06 / i I .i ETHAFOAM . . . . I I . . . . . . . . ' ' / SSIE=112.00± /. I I . . . / . . . . . . I. IE=114.67, 12" (W) . 6" SEWER -SERVICE . . . . . I . . . . . CB W9 /- PROPOSED SEWER ST11JB I APPROX. LOCATION . I I OP N IGCB \ IE=114.99, 4"(N) PER COR STD 406.1 I PER COR AS-BUILTS . . . . . I 1 RI 120. 2. . . . . . . . . . . . . . . \ . SS RATE SS . . . . . . . . �� - IE = 110.96t S` i SS . \ . . . . . SS . . . . I l SS . " 1E=117.82; 12".(W) . . . . . . . - . . . . . . . . . . . . . . . I . . . . . . . . . . . . . . . . . . . . . . . IE=118.3 ,. 12 . E . . . . . SS SS - - SS SS �0000 NEW 1" WATER SERVICE LINE AND METER PER COR NEW DRIVEWAY . . . I I I ssrnH S SEPARATE WATER METER PERMIT. PRESSURE REDUCING COR APPROACH I ( PAVEMENT `' - - VALVE REQUIRED DOWNSTREAM OF WATER METER \ - „ 1 RESTORATION PER .N . '34TH T / COR-STD 110.1 SSMH / cn . . RIM=140.76 / IE=132.47, 8" CONC. (E) SET MAG. NAIL / . . . . . . . . . . . . / -_ :. ..: IE=132.37, 8" CONC. (W) EL=117.76 7 / . . . . . . . . . . . IE=132.47, 6" CONC. (S) SSMH / RIM=118.92 IE=1�1 .15�; 8" Z`a'1 77) IE=111.82, 8" CONC. (W) SDCB . IE=112.22, 6" CONC. (S) RIM=12. NO INVI VEHICLE CIVIL1700 NW GILMAN BLVD, STE 200 ISSAQUAH, WA 98027 PHONE: (425) 821-5038 FOUND MONUMENTIN CASE BENCHMARK (P) PLAT (M) MEASURED (c) CALCULATED WATER VALVE FIRE HYDRANT ® WATER METER Q SEWER MANHOLE ❑ CATCH BASIN o MAILBOX LIGHT POLE C�1Q ROCKERY KEYSTONE WALL (OR AS NOTED) OO ELECTRIC METER UTILITY POLE GAS METER P P -P P- T W W SD SS G G .................... UNDERGROUND POWER LINE OVERHEAD POWER LINE UNDERGROUND TELEPHONE LINE WATER LINE STORM LINE SEWER LINE GAS LINE WOOD FENCE (WF) WIRE FENCE (WIF) EVERGREEN TREE DECIDUOUS TREE CONCRETE ASPHALT GRAVEL CONCRETE PAVERS & GRAVEL SOIL QUALITY NOTE ALL AREAS SUBJECT TO CLEARING AND GRADING THAT HAVE NOT BEEN COVERED BY IMPERVIOUS SURFACE, INCORPORATED INTO A DRAINAGE FACILITY OR ENGINEERED AS STRUCTURAL FILL OR SLOPE SHALL, AT PROJECT COMPLETION, DEMONSTRATE THE FOLLOWING: 1. A TOPSOIL LAYER WITH A MINIMUM ORGANIC MATTER CONTENT OF 107• DRY WEIGHT IN BEDS, AND 59 ORGANIC MATTER CONTENT IN TURF AREAS, AND A PH FROM 6.0 TO &0 OR MATCHING THE PH OF THE UNDISTURBED SOIL. THE TOPSOIL LAYER SHALL HAVE A MINIMUM DEPTH OF EIGHT INCHES EXCEPT WHERE TREE ROOTS LIMIT THE DEPTH OF INCORPORATION OF AMENDMENTS NEEDED TO MEET THE CRITERIA. SUBSOILS BELOW THE TOPSOIL LAYER SHOULD BE SCARIFIED AT LEAST 4 INCHES WITH SOME INCORPORATION OF THE UPPER MATERIAL TO AVOID STRATIFIED LAYERS, WHERE FEASIBLE. 2. MULCH PLANTING BEDS WITH 2 INCHES OF ORGANIC MATERIAL. J. USE COMPOST AND OTHER MATERIALS THAT MEET THESE ORGANIC CONTENT REQUIREMENTS. A) THE ORGANIC CONTENT FOR PRE -APPROVED" AMENDMENT RATES CAN BE MET ONLY USING COMPOST MEETING THE COMPOST SPECIFICATION FOR BIORETENTION (REFER TO SECTION C.2.6) WITH THE EXCEPTION THAT THE COMPOST MAY HAVE UP TO 359• BIOSOLIDS OR MANURE. THE COMPOST MUST ALSO HAVE AN ORGANIC MATTER CONTENT OF 407. TO 65X AND A CARBON TO NITROGEN RATIO BELOW 25.1. THE SECTION C.2 ON -SITE BMPS 1211212016 2017 CITY OF RENTON SURFACE WATER DESIGN MANUAL C-100 CARBON TO NITROGEN RATIO MAY BE AS HIGH AS 35.1 FOR PLANTINGS COMPOSED ENTIRELY OF PLANTS NATIVE TO THE PUGET SOUND LOWLANDS REGION. B) CALCULATED AMENDMENT RATES MAY BE MET THROUGH USE OF COMPOSTED MATERIAL MEETING A)" ABOVE,• OR OTHER ORGANIC MATERIALS AMENDED TO MEET THE CARBON TO NITROGEN RATIO REQUIREMENTS, AND NOT EXCEEDING THE LIMITS IDENTIFIED IN TABLE 220-B, TESTING PARAMETERS, IN WAC 173-350-220. 4. THE RESULTING SOIL SHOULD BE CONDUCIVE TO THE TYPE OF VEGETATION TO BE ESTABLISHED. DRY UTILITY NOTE GAS AND POWER UTILITIES IN THE ROW WILL REQUIRE SEPARATE FRANCHISE PERMITS. EX EX 25' ROW EX 25' ROW 1.5' DEDICATION 13' 8 LANDSCAPE Ef PAVEMENT - - p.5' VERTICAL CURB 5' SIDEWALK fAND EX PAVING VARIES 29'FOR 1' AT SAWCUMATCH EX BACK OF WALK EDGE OF PAVEMENT CURB PER COR STD PLAN 101 SIDEWALK PER COR STD PLAN 102 N 34TH STREET SECTION 1.5% MAX N TS R-436402 IN COMPLIANCE WITH CITY OF RENTON STANDARDS 05/01/2025 5 SURVEYED: SCALE: q „= q o r I I HORI ONTAL, N D 1983/1991 DATUM CITY 0 F RENTON U Planning/Building/(1 P Public Works Dept. SIERRA HOMES S F R AS -BUILT SITE GRADING DRAINAGE > > &UTILITY PLAN 4 DESIGNED: 3 2 DRAWN: JAT ONE INCH 1 STORM REVISION FOR DI PIPE EDM 5/1/2025 EDM CHECKED: EDM AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY NO. REVISION BY DATE APPR APPROVED: DATE: n7_ PAGE: _ DRAWING NO: SHEET: OF: 3 6 co m N T O It N I� J_ m cn Q LL U) LU 2 O 2 Q FLU vJ