Loading...
HomeMy WebLinkAboutCD-4335S0 0 ° 1 5 ' 5 9 " W 2 5 6 . 7 1 ' B I K E B I K E VAN B I K E W 14"FIR 16"FIR 24"FIR 12"FIR 20"FIR 16"FIR 30"FIR 16"FIR 303.5 L F WF A3 WF A5 WF A7 WF A8 WF AA8 WF AA6 WF AA5 ROCK E R Y ROCKERY - - - - LS PV LS LS LS WF AA7 WF AA4 M WATE R V A L V E WATE R M A N H O L E EXIST I N G 1 2 " G V A S P H A L T ASPH A L T AS P H A L T AS P H A L T AS P H A L T GRAVEL ASPH A L T - SIDEW A L K 24" FIR 30" Fir 18" MAPLE 30" FIR WF A6 - > SB SIGNAL BOX SB TV EXIST I N G S T R E A M N63°5 7 ' 2 7 " E 1423.1 4 ' ( M ) 1423. 2 1 ' ( S T ) 595.0 7 ' ( C ) 595.1 0 ' ( S T ) 828.0 7 ' ( C ) 828.1 1 ' ( S T ) S 2 6 ° 0 2 ' 3 3 " E 4 5 . 0 0 ' FOUND INVERTED NAIL IN CONCRETE POST, INCASED FOUND INVERTED NAIL IN CONCRETE POST, INCASED 20' SEWER EASEMENT NE SU N S E T B L V D 40.00' STREAM BUFFER PROPOSED MEDICAL OFFICE SHELL 5,200 SF FOOTPRINT 6.50' ROW DEDICATION N63° 5 7 ' 2 7 " E 184.4 5 ' N0 ° 0 0 ' 2 5 " E 17 4 . 6 8 ' N89° 37' 58"W164.55' S0 ° 1 5 ' 5 9 " W 25 6 . 7 1 ' CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N COVER SHEET C0.1 1 1" = 1/4 MILES VICINITY MAP SUNSE T B L V D 13 8 A V E S E 13 8 A V E S E AN A C O R T E S A V E UN I O N A V E N E NE NE 12TH ST SITE JON GRAVES ARCHITECTS & PLANNERS, PLLC 3110 RUSTON WAY, SUITE B TACOMA, WA 98403 PH. (253) 272-4214 FAX (253) 272-4218 CONTACT: TYLER GRAFF ARCHITECT OWNER ADF PROPERTIES, LLC 15007 WOODINVILLE-REDMOND ROAD SUITE A WOODINVILLE, WA 98072 CONTACT: MR. DALE FONK CIVIL ENGINEER CENTRE POINT CONSULTANTS, INC., PS 206 RAILROAD AVENUE NORTH KENT, WA 98032 PH. (253) 813-1901 FAX (253) 813-1908 CONTACT: STEPHEN WOODS, PLS SURVEYOR AHBL ENGINEERS, PLANNERS, & SURVEYORS 2215 NORTH 30TH STREET, SUITE 300 TACOMA, WA 98403 PH. (253) 383-2422 FAX (253) 383-2572 CONTACT: MATT WEBER, PE 0323059093 SITE ADDRESS 4401 NE SUNSET BOULEVARD RENTON, WA 98059 BASIS OF BEARING VERTICAL DATUM = NORTH AMERICAN VERTICAL DATUM NAVD 88 (CITY OF RENTON) CITY OF RENTON SURVEY CONTROL POINT 2189 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY ELEVATION: 400.60' SITE NO.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH END OF 6' CYCLONE FENCE. ELEVATION: 396.77 TRUE NORTH. BASED UPON GLOBAL POSITIONING SYSTEM (GPS) LAMBERT GRID WASHINGTON STATE NORTH ZONE COORDINATES. A CONVERGENCE ANGLE OF 00°58'31.09" COUNTERCLOCKWISE WAS APPLIED AT A BRASS PIN IN CONCRETE POST, INCASES, AT THE INTERSECTION OF 148TH AVENUE SE AND SE 112TH STREET. THE MONUMENT IS THE SOUTHEAST SECTION CORNER OF SECTION 3, TOWNSHIP 23 NORTH, RANGE 5 EAST OF THE WILLAMETTE MERIDIAN. THE NORTH AMERICAN DATUM OF 1983/1991 (NAD 83/91) GRID COORDINATES WERE FOUND TO BE 186170.695 / 1316637.784 AT THAT POINT. THE INVERSE OF BOTH THE SEA LEVEL CORRECTION FACTOR OF 0.999981199 AND THE GRID SCALE FACTOR OF 0.999999475 WAS APPLIED TO THE GRID COORDINATES FOR SHOWN GROUND DISTANCES. BENCHMARK LEGAL DESCRIPTION PARCEL NUMBER LOT 2 OF CITY OF RENTON SHORT PLAT NO. 345-79, RECORDED UNDER KING COUNTY RECORDING NO. 7908179008, BEIGN A PORTION OF THE SOUTHWEST QUARTER OF SECTION 3, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., IN KING COUNTY, WASHINGTON. CITY OF RENTON CITY OF RENTON PUGET SOUND ENERGY PUGET SOUND ENERGY QWEST COMMUNICATIONS SCHOOL DISTRICT NO. 403 RENTON FIRE UTILITIES/SERVICES WATER: SEWER: POWER: GAS: TELEPHONE: SCHOOLS: FIRE: WATER METER TRAFFIC SIGNAL BOX SANITARY SEWER LINE ON-SITE CLEARING LIMITS ROOF DRAIN LINE PROPOSED PAVING STORM DRAIN LINE WATER LINE CHAIN LINK FENCE CONTOURS WOOD FENCE WIRE FENCE SIGNAL POLE RD W D S FIRE DEP'T CONNECTION WATER VALVE HYDRANT DRAIN MH CLEANOUT SANITARY MH SIGN GUY WIRE CATCH BASIN TELEPHONE MH TELEPHONE RISER MONUMENT POWER/TELE. POLE LIGHT LEGEND EXISTING DESCRIPTION PROPOSED UTILITY NOTE TRENCH NOTE FILL SPECIFICATION IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3)B, IT SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKER SAFETY AND AHBL ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17 RCW. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. AHBL ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. IMPORTED FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH OTHERWISE VIOLATE ANY STATE, FEDERAL, OR LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE, ORDER, OR STANDARD. TOPOGRAPHIC NOTE THE EXISTING CULTURAL AND TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, AHBL CANNOT ENSURE ACCURACY AND THUS IS NOT RESPONSIBLE FOR THE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. RENTON CONTROL MONUMENTS CITY OF RENTON CONTROL POINT 2097. CONTROL POINT 2097 WAS FOUND TO HAVE A LAMBERT GRIDE NORTH ZONE COORDINATE OF 191108.643 FT. / 1316760.378 FT. CITY OF RENTON CONTROL POINT 1845. CONTROL POINT 1845 WAS FOUND TO HAVE A LAMBERT GRID NORTH ZONE COORDINATE OF 186170.657 FT. / 1316637.843 FT. ELEV WETLAND RESOURCES 9505 19TH AVE. SE, SUITE 106 EVERETT, WA 98208 PH. (425) 337-3174 CONTACT: SCOTT BRAINARD WETLAND CONSULTANT SHEET INDEX PAGE #SHEET #SHEET TITLE 1 C0.1 COVER SHEET 2 C1.1 TESC AND DEMOLITION PLAN 3 C1.2 TESC NOTES AND DETAILS 4 C1.3 TESC NOTES AND DETAILS 5 C2.1 GRADING PLAN 6 C3.1 FRONTAGE IMPROVEMENTS PLAN 7 C3.2 FRONTAGE IMPROVEMENTS DETAILS 8 C3.3 FRONTAGE IMPROVEMENTS DETAILS 9 C4.1 STORM DRAINAGE PLAN 10 C4.2 SITE SECTIONS 11 C4.3 STORM NOTES AND DETAILS 12 C4.4 STORM NOTES AND DETAILS 13 C4.5 STORM NOTES AND DETAILS 14 C4.6 STORM NOTES AND DETAILS 15 C4.7 STORM NOTES AND DETAILS 16 C4.8 STORM NOTES AND DETAILS 17 C4.9 STORM NOTES AND DETAILS 18 C5.1 UTILITY PLAN 19 C5.2 SEWER NOTES AND DETAILS 20 C5.3 SEWER NOTES AND DETAILS 21 C5.4 WATER NOTES AND DETAILS 22 C5.5 WATER NOTES AND DETAILS 23 C5.6 WATER NOTES AND DETAILS 24 C5.7 WATER NOTES AND DETAILS 25 C6.1 HORIZONTAL CONTROL & SURFACING PLAN 26 C6.2 SURFACING NOTES AND DETAILS 27 C7.1 COMPOSITE UTILITY PLAN 28 C8.1 GARBAGE TRUCK TURNING EXHIBIT 29 L1.00 LANDSCAPE PLAN 30 L1.01 PLANT LEGEND AND IMAGES 31 L1.02 PLANTING DETAILSS 32 P1.0 PHOTOMETRIC CALCULATIONS 33 IL1.0 ILLUMINATION PLAN 34 IL1.1 ILLUMINATION DETAILS Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - C O V R . d w g R-433501 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 amorganroth 07/22/2025 CURRENT PLANNING Surface Water Enginering jfarah 07/23/2025 WATER UTILITY ABDOUL GAFOUR 07/25/2025 REGIONAL FIRE AUTHORITY cthomas 07/28/2025 APPROVED WASTEWATER UTILITY jstowell 07/28/2025 SANITARY SEWER MANHOLE RIM 400.93 8" CONC N 391.53 IE 12" CONC NE 390.88 IE 6" CONC S 391.82 IE 12" CONC SW 390.90 IE W 14"FIR 16"FIR 24"FIR 12"FIR 20"FIR 16"FIR 30"FIR 16"FIR 177.5 L F SANITARY SEWER MANHOLE RIM 396.32 8" PVC S 393.35 IE 8" PVC SE 393.38 IE 8" PVC N 393.27 IE 303.5 L F WF A3 WF A5 WF A7 WF A8 WF AA8 WF AA6 WF AA5 ROCK E R Y ROCKERY GUAR D R A I L - - - - - GUAR D R A I L 6' CY C L O N E F E N C E LS PV LS LS LS WF AA7 WF AA4 M ---- WATE R V A L V E WATE R M A N H O L E EXIST I N G 1 2 " G V A S P H A L T ASPH A L T AS P H A L T AS P H A L T AS P H A L T GRAVEL ASPH A L T - CURB D R O P SIDEW A L K 24" FIR 24" CEDAR 30" Fir 18" MAPLE 30" FIR WF A6 CATCH BASIN RIM 398.80 12" CONC NE 394.86 IE 12" CONC N 394.84 IE 12" CONC SW 394.91 IE SANITARY SEWER MANHOLE RIM 400.43 12" CONC NE 388.08 IE 8" PVC S 388.91 IE 12" CONC SW 388.08 IE CATCH BASIN RIM 399.93 12" CONC NE 395.33 IE 12" CONC SW 395.21 IE SANITARY SEWER MANHOLE RIM 398.25 12" CONC NE 386.00 IE 12" CONC SW 385.95 IE SANITARY SEWER MANHOLE RIM 400.71 12" CONC NE 388.80 IE 12" CONC SW 388.61 IE - > SB SIGNAL BOX SB TV EXIST I N G S T R E A M N63°5 7 ' 2 7 " E 1423. 1 4 ' ( M ) 1423. 2 1 ' ( S T ) 595.0 7 ' ( C ) 595.1 0 ' ( S T ) 828.0 7 ' ( C ) 828.1 1 ' ( S T ) S 2 6 ° 0 2 ' 3 3 " E 4 5 . 0 0 ' FOUND INVERTED NAIL IN CONCRETE POST, INCASED 48" CMP CULVERT 389.11 IE 8" CONCRETE CULVERT 393.56 IE 21" FIR CATCH BASIN RIM 400.13 12" CONC SW 397.30 IE CATCH BASIN RIM 400.78 12" CONC SW 397.38 IE 20' SEWER EASEMENT S0 ° 1 5 ' 5 9 " W 25 6 . 7 1 ' N89° 37' 58"W164.55' N0 ° 0 0 ' 2 5 " E 17 4 . 6 8 ' N63° 5 7 ' 2 7 " E 184.4 5 ' NE SU N S E T B L V D 40.00' STREAM BUFFER 400 39 6 396 397 398 398 398 399 397 397 398 39 8 39 9 TYP. TYP. TYP. AFTER CB INSTALLATION CONTRACTOR TO STABILIZE ALL DISTURBED PORTIONS OF THE SITE USING SEED, MULCH, OR OTHER ENGINEER APPROVED BMP. AFTER CB INSTALLATION AFTER CB INSTALLATION 400 39 9 401 CL CL IP CE TS TS TS SF SFVR VR VR SF CL CL CP IP TEMPORARY SOIL STOCKPILE AREA, SEE STOCKPILE NOTES ON SHEET C2.2 REMOVE SIDEWALK TO NEAREST JOINT REMOVE DRIVWAY, REMOVE AND REPLACE CURB AS REQUIRED REMOVE DRIVWAY, REMOVE AND REPLACE CURB AS REQUIRED REMOVE SIDEWALK TO NEAREST JOINT REMOVE SIDEWALK ALONG FRONTAGE REMOVE GUARD RAIL REMOVE GUARD RAIL P P FUTURE BUILDING OUTLINE (TYP.) FILL SLOPE CATCH LINE (TYP.) FILL SLOPE CATCH LINE (TYP.) FILL SLOPE CATCH LINE (TYP.) REMOVE TREE IP IP IP PROVIDE SELECT CLEARING AS REQUIRED FOR STORM INSTALLATION PROVIDE CONSTRUCTION FENCE AROUND TREE DRIPLINE TO PROTECT DURING CONSTRUCTION PROVIDE CONSTRUCTION FENCE AROUND TREE DRIPLINE TO PROTECT DURING CONSTRUCTION PROVIDE CONSTRUCTION FENCE AROUND TREE DRIPLINE TO PROTECT DURING CONSTRUCTION PROTECT EXISTING FENCE DURING CONSTRUCTION SL REMOVE EXISTING METER, EXISTING SERVICE LINE TO BE CUT AND CAPPED CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N TESC AND DEMOLITION PLAN C1.1 2 TEMPORARY CONSTRUCTION ENTRANCE PER RENTON DETAIL 215.10 STORM DRAIN INLET PROTECTION PER RENTON DETAIL 216.30 SILT FENCE PER RENTON DETAIL 214.00 CLEAR PLASTIC COVERING, SEE PLASTIC COVERING NOTES ON SHEET C1.2 TEMPORARY SEEDING, SEE HYDROSEEDING NOTES CLEARING LIMITS NATURAL VEGETATION RETENTION PROTECT UTILITY AND BRING TO GRADE SAWCUT LINE T.E.S.C. LEGEND CONSTRUCTION SEQUENCE 1.SURVEY AND FLAG CLEARING LIMITS. 2.SCHEDULE AND ATTEND PRECONSTRUCTION MEETING WITH CITY OF RENTON. 3.PROVIDE MISC. DEMOLITION AND CLEAR AND GRUB AREA WITHIN CLEARING LIMITS REQUIRED FOR INSTALLATION OF TEMPORARY EROSION CONTROL FACILITIES. ALL EROSION AND SEDIMENT CONTROL FACILITIES SHOWN ON THE EROSION CONTROL PLAN SHALL BE INSTALLED PRIOR TO, OR AS A FIRST STAGE OF SITE PREPARATION. 4.PROVIDE CONSTRUCTION ENTRANCE, SILT FENCE, AND CATCH BASIN INLET PROTECTION AS SHOWN ON SHEET C1.2. 5.THE CONTRACTOR SHALL INSPECT EROSION CONTROL MEASURES WEEKLY AND PROVIDE REPAIRS AS NEEDED. 6.PROVIDE COVER MEASURES TO INCLUDE ARMORING, MULCHING AND HYDROSEEDING TO STABILIZE DENUDED AREAS AND PREVENT THE TRANSPORT OF SEDIMENT-LADEN STORMWATER OFF-SITE. 7.PROVIDE STORM SYSTEM, SANITARY SYSTEM, WATER AND MISCELLANEOUS UTILITIES AS SHOWN ON THE PLANS. PROVIDE 6" VERTICAL AND 3' HORIZONTAL CLEARANCE (OUTSIDE SURFACES) BETWEEN STORM DRAIN LINES AND OTHER UTILITY PIPES AND CONDUITS. 8.PROVIDE CATCH BASIN SEDIMENT PROTECTION ON ALL CATCH BASINS. 9.AFTER SITE IS STABILIZED, COMPLETE BIO-RETENTION CONSTRUCTION: 9.1.SCARIFY ALL BIO-RETENTION SUB-GRADES (DO NOT COMPACT BIO-RETENTION BOTTOMS) 9.2.SCHEDULE GEOTECHNICAL ENGINEER FOR INFILTRATION TESTING TO ENSURE BIO-RETENTION FUNCTION PER DESIGN. PROVIDE INFILTRATION TESTING TO INCLUDE A MINIMUM OF 2 TESTS PER BIO-RETENTION SYSTEM. INFILTRATION TESTING PER PIERCE COUNTY STORMWATER MANAGEMENT AND SITE DEVELOPMENT MANUAL. CITY MUST BE NOTIFIED AT LEAST 2 BUSINESS DAYS PRIOR TO INFILTRATION TESTING. 9.3.UPON APPROVAL OF INFILTRATION TESTING RESULTS, PROVIDE BIO-RETENTION TREATMENT SOIL MIX PER PLANS. BIO-RETENTION SOIL MIX PLACEMENT AND BIO-RETENTION EXCAVATION SHALL NOT BE CONDUCTED DURING WET OR SATURATED CONDITIONS. 9.4.PROVIDE LANDSCAPE PLANTINGS AND FINAL BIO-RETENTION STABILIZATION PER LANDSCAPE DESIGN. 10.FINE GRADE SITE AND PAVE. COORDINATE WITH THE CITY FOR REQUIRED INSPECTIONS. 11.REMOVE SEDIMENT FROM STORM PIPES AND CATCH BASIN SUMPS. 12.STABILIZE ALL REMAINING DISTURBED AREAS. 13.COORDINATE WITH THE CITY OF RENTON FOR FINAL INSPECTION. 14.REMOVE REMAINING TEMPORARY EROSION CONTROL DEVICES WHEN AREA HAS BEEN PERMANENTLY STABILIZED WITH VEGETATION AND REMOVAL IS APPROVED BY THE CITY. T.E.S.C. GENERAL NOTES: 1.AT A MINIMUM, ALL T.E.S.C. FEATURES SHALL BE INSPECTED AND MAINTAINED PER THE SCHEDULE PROVIDED ON THIS SHEET. 2.TREES TO BE PROTECTED SHALL BE SURROUNDED BY CONSTRUCTION FENCING AT THE DRIP LINE. ANY CLEARING REQUIRED INSIDE THE DRIP LINE SHALL BE PERFORMED BY HAND TO PREVENT DAMAGE TO THE ROOTS. IF ROOTS GREATER THAN 1" IN DIAMETER ARE DAMAGED DURING CLEARING OR GRADING, THEY SHALL BE SEALED WITH EMULSIFIED ASPHALT AND COVERED WITH WET BURLAP TO PREVENT THE ROOTS FROM DRYING OUT PRIOR TO BE RECOVERED. COVER EXPOSED ROOTS WITH SOIL AS SOON AS PRACTICABLE. EROSION CONTROL AND SEDIMENT CONTROL (ESC) FACILITIES SHALL NOT BE ALLOWED TO FALL INTO DISREPAIR. ALL ESC FACILITIES SHALL BE INSPECTED AS A MINIMUM, ACCORDING TO THE FOLLOWING SCHEDULE: DRY SEASON: ONCE A WEEK WET SEASON: DAILY, AND AFTER EVERY RAINFALL EVENT PRODUCING RUNOFF. NEEDED REPAIRS SHALL BE MADE WITHIN 24 HOURS OR IMMEDIATELY IF POSSIBLE. INSPECTION SCHEDULE FOR ESC FACILITIES P VR CL TS CP SF IP CE 2 C1.2 3 C1.2 1 C1.2 SL Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - T E S C . d w g R-433502 LANDUSE CONDITION OF APPROVAL 1.THE APPLICANT SHALL RETAIN EITHER THE 29-INCH ( 29”) DBH DOUGLAS FIR TREE OR THE 27-INCH ( 27”) DBH DOUGLAS FIR TREE IDENTIFIED IN THE ARBORIST REPORT SUBMITTED WITH THE APPLICATION. 2.A SCREENING DETAIL FOR ANY PROPOSED SURFACE OR ROOF MOUNTED UTILITY EQUIPMENT BE SUBMITTED TO THE CURRENT PLANNING PROJECT MANAGER FOR REVIEW AND APPROVAL. THE SCREENING DETAIL FOR SURFACE MOUNTED UTILITY EQUIPMENT THAT INCLUDES CROSS SECTIONS OF THE UTILITY AND SCREENING SHALL BE PROVIDED AT THE TIME OF CONSTRUCTION PERMIT REVIEW. 3.THE APPLICANT SHALL SUBMIT A LETTER FROM THE GARBAGE AND RECYCLING SERVICE PROVIDER APPROVING THE LOCATION OF THE ENCLOSURE. THE LETTER SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO CIVIL CONSTRUCTION PERMIT ISSUANCE. 4.A BICYCLE PARKING DETAIL BE SUBMITTED AT THE TIME OF BUILDING PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER DEMONSTRATING THAT THE PROPOSAL WOULD COMPLY WITH THE BICYCLE PARKING REQUIREMENTS AS REQUIRED IN RMC 4-4-080F.11. 5.THE APPLICANT SHALL SUBMIT A LIGHTING PLAN THAT DEMONSTRATES COMPLIANCE WITH RMC 4-4-075 AND PROVIDES ENOUGH LIGHT FOR SECURITY BUT DOES NOT CREATE EXCESSIVE LIGHT IMPACTS ON NEIGHBORING PROPERTIES. IN ADDITION, THE PARKING AND PEDESTRIAN AREAS SHALL ALSO CONTAIN ADEQUATE LIGHTING TO ENSURE SAFETY AND SECURITY. THE LIGHTING PLAN SHALL INCLUDE DETAILED SHEETS OF ALL EXISTING AND NEW LIGHT FIXTURES ON SITE, FOOTCANDLE ILLUMINATION INFORMATION, AND SHALL BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO CIVIL CONSTRUCTION PERMIT ISSUANCE. 6.THE APPLICANT SHALL PROVIDE A SERVICE AREA SCREENING DETAIL AT THE TIME OF BUILDING PERMIT REVIEW DEMONSTRATING THAT THE SERVICE ELEMENT DOORS WOULD BE SELF- CLOSING. 7.THE SECTION OF THE ON-SITE SIDEWALK BETWEEN THE PUBLIC SIDEWALK IN NE SUNSET BLVD AND THE PLAZA AREA NEAR THE MAIN ENTRANCE SHALL HAVE A MINIMUM WIDTH OF SIX FEET ( 6’). 8.THE APPLICANT SHALL INSTALL TWO ( 2) BENCHES, OR AN ALTERNATIVE SEATING OPTION, NEAR EITHER THE FRONT OR ADJACENT REAR ENTRANCE OF THE BUILDING. THE SITE FURNITURE LOCATIONS AND DETAILS DEMONSTRATING COMPLIANCE WITH THE DESIGN STANDARDS SHALL BE PROVIDED WITH THE BUILDING PERMIT APPLICATION FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. 9.THE APPLICANT SHALL SUBMIT A MATERIALS BOARD TO THE CURRENT PLANNING PROJECT MANAGER AT THE TIME OF BUILDING PERMIT REVIEW FOR REVIEW AND APPROVAL. 10.THE APPLICANT SHALL SUBMIT AN INTERNAL TRAFFIC CIRCULATION ANALYSIS THAT DEMONSTRATES HOW VEHICLES WOULD SAFELY ENTER AND EXIT THE PARKING LOT ON THE SITE. THE ANALYSIS SHALL EVALUATE TURNING MOVEMENTS BOTH INTO AND OUT OF THE STALLS, AS WELL AS IDENTIFY WHERE DRIVERS COULD SAFELY TURNAROUND ON THE SITE IF ALL PARKING STALLS WERE FILLED. THE ANALYSIS SHALL BE REVIEWED OR APPROVED PRIOR TO ISSUANCE OF THE CIVIL CONSTRUCTION PERMIT. 11.THE APPLICANT SHALL SUBMIT AN UPDATED SITE PLAN IDENTIFYING A LOADING AND DELIVERY AREA SEPARATE FROM THE CUSTOMER/EMPLOYEE PARKING AND PEDESTRIAN AREAS. THE UPDATED SITE PLAN SHALL BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO CONSTRUCTION PERMIT ISSUANCE. 12.THE APPLICANT SHALL SUBMIT A SIGNED AND SEALED LETTER FROM A LICENSED GEOTECHNICAL ENGINEER STATING THAT THEY HAVE REVIEWED THE CONSTRUCTION PLANS AND, IN THEIR OPINION, THE PROPOSED PLANS AND SPECIFICATIONS MEET THE INTENT OF THE REPORT. THE LETTER SHALL BE SUBMITTED TO THE CURRENT PLANNING PROJECT MANAGER PRIOR TO ISSUANCE OF THE CIVIL CONSTRUCTION PERMIT. 13.THE APPLICANT SHALL PROVIDE DOCUMENTATION OF THE EXISTING 20-FOOT (20’) WIDE SEWER EASEMENT ON THE SITE. THE DOCUMENT SHALL BE REVIEWED AND APPROVED BY THE PUBLIC WORKS PLAN REVIEWER PRIOR TO ISSUANCE OF THE CIVIL CONSTRUCTION PERMIT. IF NO EASEMENT IS FOUND TO EXIST, THE APPLICANT SHALL ESTABLISH A NEW SEWER EASEMENT PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR THE NEW BUILDING. THE LOCATION, SIZE, AND LANGUAGE OF THE EASEMENT SHALL BE REVIEWED AND APPROVED BY THE PUBLIC WORKS PLAN REVIEWER PRIOR TO ISSUANCE OF THE CIVIL CONSTRUCTION PERMIT. IN ADDITION, A PAVED ACCESS ROAD TO THE EXISTING SEWER MANHOLE ( COR FACILITY ID MH 3619) WITHIN THE 20 FEET WIDE EASEMENT SHALL BE PROVIDED. NO STRUCTURES SHALL BE INSTALLED WITHIN THE EXISTING EASEMENT, AND THE PROPOSED BIORETENTION CELL SHALL BE LOCATED OUTSIDE OF THE EXISTING PUBLIC UTILITY EASEMENT. 14.THE PROPOSAL SHALL CONFORM TO ALL RECOMMENDATIONS MADE IN THE APPLICANT’ S STREAM STUDY AND BUFFER MITIGATION PLAN, PREPARED BY WETLAND RESOURCES, INC., DATED MAY 30, 2024 EXHIBIT 13). 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 AT MAIN BY CITY FORCES. CUT AND CAP PERMIT REQUIRED CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 TESC NOTES AND DETAILS C1.2 3 1.STOCKPILES SHALL BE STABILIZED (WITH PLASTIC COVERING OR OTHER APPROVED DEVICE) DAILY BETWEEN NOVEMBER 1 AND MARCH 31. 2.IN ANY SEASON, SEDIMENT LEACHING FROM STOCK PILES MUST BE PREVENTED. 3.TOPSOIL SHALL NOT BE PLACED WHILE IN A FROZEN OR MUDDY CONDITION, WHEN THE SUBGRADE IS EXCESSIVELY WET, OR WHEN CONDITIONS EXIST THAT MAY OTHERWISE BE DETRIMENTAL TO PROPER GRADING OR PROPOSED SODDING OR SEEDING. 4.PREVIOUSLY ESTABLISHED GRADES ON THE AREAS TO BE TOPSOILED SHALL BE MAINTAINED ACCORDING TO THE APPROVED PLAN. 1.PLASTIC SHEETING SHALL HAVE A MINIMUM THICKNESS OF 6 MILS AND SHALL MEET THE REQUIREMENTS OF THE STATE STANDARD SPECIFICATIONS SECTION 9-14.5. 2.COVERING SHALL BE INSTALLED AND MAINTAINED TIGHTLY IN PLACE BY USING SANDBAGS OR TIRES ON ROPES WITH A MAXIMUM 10-FOOT GRID SPACING IN ALL DIRECTIONS. ALL SEAMS SHALL BE TAPED OR WEIGHTED DOWN FULL LENGTH AND THERE SHALL BE AT LEAST A 12 INCH OVERLAP OF ALL SEAMS. 3.CLEAR PLASTIC COVERING SHALL BE INSTALLED IMMEDIATELY ON AREAS SEEDED BETWEEN NOVEMBER 1 AND MARCH 31 AND REMAIN UNTIL VEGETATION IS FIRMLY ESTABLISHED. 4.WHEN THE COVERING IS USED ON UN-SEEDED SLOPES, IT SHALL BE KEPT IN PLACE UNTIL THE NEXT SEEDING PERIOD. 5.PLASTIC COVERING SHEET SHALL BE BURIED TWO FEET AT THE TOP OF SLOPES IN ORDER TO PREVENT SURFACE WATER FLOW BENEATH SHEETS. 6.PROPER MAINTENANCE INCLUDES REGULAR CHECKS FOR RIPS AND DISLODGED ENDS. PLASTIC COVERING NOTES:SOIL STOCKPILE NOTES: 1.MULCH MATERIALS USED SHALL BE HAY OR STRAW, AND SHALL BE APPLIED AT THE RATE OF 2 TONS/ACRE. (MIN. 2" THICK) 2.MULCHES SHALL BE APPLIED IN ALL AREAS WITH EXPOSED SLOPES GREATER THAN 2:1. 3.MULCHING SHALL BE USED IMMEDIATELY AFTER SEEDING OR IN AREAS WHICH CANNOT BE SEEDED BECAUSE OF THE SEASON. 4.ALL AREAS NEEDING MULCH SHALL BE COVERED BY NOVEMBER 1. MULCHING NOTES: 1 NOT TO SCALE SILT FENCE 2 NOT TO SCALE CONSTRUCTION ENTRANCE 3 NOT TO SCALE CATCH BASIN INSERT Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - T E S C . d w g R-433503 10. SEED SHALL NOT BE USED IN AREAS SUBJECT TO WEAR BY CONSTRUCTION TRAFFIC. 3. APPLICATION TO BE 100 LBS/ACRE. SEDIMENT BASINS. AND WETLANDS. 6. FOR SEED BEDS PLANTED BETWEEN OCTOBER 31 AND APRIL 30, ARMORING OF THE 7. BEFORE SEEDING, INSTALL NEEDED SURFACE RUNOFF CONTROL MEASURES SUCH 8. THE SEEDBED SHALL BE FIRM WITH A FAIRLY FINE SURFACE, FOLLOWING SURFACE 9. FERTILIZERS ARE TO BE USED ACCORDING TO SUPPLIERS RECOMMENDATIONS. 5. SEED BEDS PLANTED BETWEEN MAY 1 AND OCTOBER 31 WILL REQUIRE IRRIGATION 4. 500 LBS/ACRE 10-20-20 FERTILIZER, 2000 LBS/ACRE WOOD FIBER CELLULOSE AND AND OTHER MAINTENANCE AS NECESSARY TO FOSTER AND PROTECT THE ROOT SEED BED WILL BE NECESSARY. (E.G., GEOTEXTILES, JUTE MAT, CLEAR PLASTIC AS GRADIENT TERRACES, INTERCEPTOR DIKES, SWALES, LEVEL SPREADERS AND ROUGHENING. PERFORM ALL OPERATIONS ACROSS OR AT RIGHT ANGLES TO THE AMOUNTS USED SHOULD BE MINIMIZED, ESPECIALLY ADJACENT TO WATER BODIES 40 LBS/ACRE SOIL BINDER OR TACKING AGENT TO BE APPLIED WITH SEED MIXTURE. COVERING.) SLOPE. STRUCTURE. NOTES" ON THIS SHEET. HYDROSEEDING NOTES: 2. HYDROSEEDING TO BE THE FOLLOWING MIXTURE: 1. HYDROSEEDING SHALL BE APPLIED IN ACCORDANCE WITH THE "EROSION CONTROL 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 TESC NOTES AND DETAILS C1.3 4 Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - T E S C . d w g R-433504 1 TREE PROTECTION FENCING 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 S0 0 ° 1 5 ' 5 9 " W 2 5 6 . 7 1 ' B I K E B I K E VAN B I K E SANITARY SEWER MANHOLE RIM 400.93 8" CONC N 391.53 IE 12" CONC NE 390.88 IE 6" CONC S 391.82 IE 12" CONC SW 390.90 IE W 14"FIR 16"FIR 24"FIR 12"FIR 20"FIR 16"FIR 30"FIR 16"FIR 177.5 L F SANITARY SEWER MANHOLE RIM 396.32 8" PVC S 393.35 IE 8" PVC SE 393.38 IE 8" PVC N 393.27 IE 303.5 L F WF A3 WF A5 WF A7 WF A8 WF AA8 WF AA6 WF AA5 ROCK E R Y ROCKERY - - - - LS PV LS LS LS WF AA7 WF AA4 M WATE R V A L V E WATE R M A N H O L E EXIST I N G 1 2 " G V A S P H A L T ASPH A L T AS P H A L T AS P H A L T AS P H A L T GRAVEL ASPH A L T - SIDEW A L K 24" FIR 30" Fir 18" MAPLE 30" FIR WF A6 CATCH BASIN RIM 398.80 12" CONC NE 394.86 IE 12" CONC N 394.84 IE 12" CONC SW 394.91 IE SANITARY SEWER MANHOLE RIM 400.43 12" CONC NE 388.08 IE 8" PVC S 388.91 IE 12" CONC SW 388.08 IE CATCH BASIN RIM 399.93 12" CONC NE 395.33 IE 12" CONC SW 395.21 IE SANITARY SEWER MANHOLE RIM 398.25 12" CONC NE 386.00 IE 12" CONC SW 385.95 IE SANITARY SEWER MANHOLE RIM 400.71 12" CONC NE 388.80 IE 12" CONC SW 388.61 IE - > SB SIGNAL BOX SB TV EXIST I N G S T R E A M N63°5 7 ' 2 7 " E 1423.1 4 ' ( M ) 1423. 2 1 ' ( S T ) 595.0 7 ' ( C ) 595.1 0 ' ( S T ) 828.0 7 ' ( C ) 828.1 1 ' ( S T ) S 2 6 ° 0 2 ' 3 3 " E 4 5 . 0 0 ' FOUND INVERTED NAIL IN CONCRETE POST, INCASED FOUND INVERTED NAIL IN CONCRETE POST, INCASED 48" CMP CULVERT 389.11 IE 8" CONCRETE CULVERT 393.56 IE CATCH BASIN RIM 400.13 12" CONC SW 397.30 IE CATCH BASIN RIM 400.78 12" CONC SW 397.38 IE 20' SEWER EASEMENT S0 ° 1 5 ' 5 9 " W 25 6 . 7 1 ' N89° 37' 58"W164.55' N0 ° 0 0 ' 2 5 " E 17 4 . 6 8 ' N63° 5 7 ' 2 7 " E 184.4 5 ' NE SU N S E T B L V D 40.00' STREAM BUFFER 400 39 6 397 397 3 9 8 399 401 401 397 39 8 39 9 FF: 399.50 FG: 398.76 FG: 398.43 FG: 398.89 FG: 400.20 FG: 399.72 FG: 398.41 FG: 397.81 FG: 397.77 FG: 397.60 FG: 397.70 FG: 398.22 FG: 398.37 FG: 398.08 FG: 398.26 FG: 398.66 FG: 398.88 FG: 399.41 FG: 399.49 FG: 399.20 FG: 399.30 FG: 401.13 6 . 6 6 % 0. 6 6 % 1.59% 1 . 0 7 % 2 . 0 0 % 2 . 0 0 % 2 . 0 0 % FG: 398.88 1 2 . 5 0 % 1 0 . 5 9 % 6.63% 6.09% 11.58% 0. 7 0 % 2.11% 1.02% CONCRETE VALLEY GUTTER CB #2 RIM: 397.78 CO #4 RIM: 397.85 CO #3 RIM: 399.21 CO #2 RIM: 399.82 CO #7 RIM: 397.00 CB #4 RIM: 398.45 CB #5 RIM: 397.90 CB #1 RIM: 398.05 TW: 397.42 TW: 399.43 TW: 399.50 TW: 399.50 TW: 397.87 BW: 397.87 BW: 397.62 BW: 397.66 BW: 397.49 BW: 397.42 FG: 397.95 FG: 397.75 5.7 8 % FG: 397.85 GRADE AT BACK OF CURB ALONG THE BIO-RETENTION POND TO BE SET AT TOP OF POND ELEVATION 1.03% 1.01% FG: 396.22 FG: 396.10 2.86% 1.49% 4.37% 1. 4 2 % 1.55%1 . 5 9 % 1 . 0 0 % 1.2 5 % 1.2 3 % 8 . 0 0 % 8 . 0 0 % PROPOSED MEDICAL OFFICE SHELL 5,200 SF FOOTPRINT FG: 397.38 FG: 398.58 FG: 401.09 FG: 401.11 FG: 400.92 FG: 400.88 FG: 398.24 FG: 398.54 FG: 398.38 FG: 398.29 FG: 398.60 0.80% FG: 399.39 FG: 399.32 FG: 399.42 FG: 399.29 1 . 2 3 % 1 . 4 4 % 1 . 2 4 % FG: 397.66 FG: 397.88 FG: 398.15 FG: 398.24 FG: 398.33 FG: 398.42 FG: 397.83 FG: 398.06 FG: 398.15 FG: 398.24 FG: 398.33 FG: 396.33 FG: 397.06 FG: 396.54 3 . 3 8 % PROPERTY LINE PROPOSED BUILDING 2' MSE OR BLOCK WALL, CONTRACTOR TO DESIGN 4" PERFORATED FOOTING DRAIN EXISTING GRADE PROPOSED GRADE CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N GRADING PLAN C2.1 5 VERTICAL DATUM = NORTH AMERICAN VERTICAL DATUM NAVD 88 (CITY OF RENTON) CITY OF RENTON SURVEY CONTROL POINT 2189 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY ELEVATION: 400.60' SITE NO.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH END OF 6' CYCLONE FENCE. ELEVATION: 396.77 BENCHMARK EARTHWORK SITE AREA:34,000 SF PROPOSED CUT:0 CU YD PROPOSED FILL:1,590 CU YD (IMPORT) EARTHWORK QUANTITIES PROVIDED ARE FOR PERMITTING PURPOSES ONLY, CONTRACTOR SHALL DETERMINE EARTHWORK QUANTITIES FOR CONSTRUCTION EDGE OF STREAM STREAM BUFFER STREAM BUFFER Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - G R A D . d w g SEE SHEET C4.5 FOR WALL ELEVATIONS 3 C4.8 ACCESSIBLE PARKING 1 C6.1 GENERAL NOTE ALL NEW AND EXISTING POWER AND COMMUNICATION SERVICES SHALL BE UNDERGROUND. 2' MSE OR BLOCK WALL, CONTRACTOR TO DESIGN 1 NOT TO SCALE WALL SECTION 1 C2.1 R-433505 0.25' 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 W 303.5 LF - LS PV LS MWATER VALVE WATER MANHOLE EXISTING 12" GV AS P H A L T ASPHALT GR A V E L ASPHALT SIDEWALK - >SB SIG N A L B O X SB TV N63°57'27"E 1423.14' (M) 1423.21' (ST) 595.07' (C) 595.10' (ST) 828.07' (C) 828.11' (ST) S2 6 ° 0 2 ' 3 3 " E 4 5 . 0 0 ' FO U N D I N V E R T E D N A I L I N CO N C R E T E P O S T , I N C A S E D FO U N D I N V E R T E D N A I L I N CO N C R E T E P O S T , I N C A S E D NE SUNSET BLVD 400 39 9 401 400 399 401 401 400 6.5' R.O.W. DEDICATION 1 C3.1 8.00' SIDEWALK 24' 8.00' SIDEWALK 5.00' PROTECT EXISTING CATCH BASIN TYPE C1B CONCRETE DRIVEWAY CATCH BASIN RIM 398.80 12" CONC NE 394.86 IE 12" CONC N 394.84 IE 12" CONC SW 394.91 IE CATCH BASIN RIM 400.13 12" CONC SW 397.30 IE SANITARY SEWER MANHOLE RIM 398.25 12" CONC NE 386.00 IE 12" CONC SW 385.95 IE CATCH BASIN RIM 399.93 12" CONC NE 395.33 IE 12" CONC SW 395.21 IE SANITARY SEWER MANHOLE RIM 400.43 12" CONC NE 388.08 IE 8" PVC S 388.91 IE 12" CONC SW 388.08 IE SANITARY SEWER MANHOLE RIM 400.71 12" CONC NE 388.80 IE 12" CONC SW 388.61 IE 20' SEWER EASEMENT CATCH BASIN RIM 400.78 12" CONC SW 397.38 IE SANITARY SEWER MANHOLE RIM 400.93 8" CONC N 391.53 IE 12" CONC NE 390.88 IE 6" CONC S 391.82 IE 12" CONC SW 390.90 IE 177.5 LF 15.00'UTILITY PATCH EG: 399.97 EG: 400.26 EG: 400.28 EG: 400.78 EG: 399.57 TC:400.56 FL: 400.06 TC:400.79 FL: 400.29 TC:401.50 FL: 401.00 TC:400.28 FL: 400.28 TC:400.08 FL: 400.08 TC:401.00 FL: 400.50 PROPOSED MEDICAL OFFICE SHELL 5,200 SF FOOTPRINT BRING SIGNAL BOX TO GRADE BRING SIGNAL BOX TO GRADE 390 395 400 405 390 395 400 405 10+00 FG FG 4 0 0 . 9 5 10+50 FG 3 9 9 . 1 9 EXISTING ROW BOUNDARY PROPOSED ROW BOUNDARY PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE PROPOSED GRADE ELEV. AT SECTION LINE EXISTING GRADE ELEV. AT SECTION LINE 6.50' 7.2% 8.00' SIDEWALK CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N FRONTAGE IMPROVEMENTS PLAN C3.1 6 VERTICAL DATUM = NORTH AMERICAN VERTICAL DATUM NAVD 88 (CITY OF RENTON) CITY OF RENTON SURVEY CONTROL POINT 2189 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY ELEVATION: 400.60' SITE NO.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH END OF 6' CYCLONE FENCE. ELEVATION: 396.77 BENCHMARK 1 SCALE: H:1"=20', V:1"=2' DRIVEWAY SECTION 2 C3.3 Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - F R O N T A G E . d w g CE N T E R L I N E EX . R O W 28.5' ± 45' ROW 15' 8' SIDEWALK BUILDING WALL EXISTING PAVEMENT PR O P . R O W 6.5' 6" 1.5% MAX MATCH EXISTING FLOWLINE GRADE 2' MATCH EXISTING GRADE @ SAWCUT 7" HMA 6" CSTC VARIES 8' BUFFER 1' 4" CEMENT CONCRETE SIDEWALK 2 C3.22" CRUSHED SURFACING TOP COURSE 1 C3.3 3 C3.3 2 NOT TO SCALE NE SUNSET BLVD SECTION 2 C3.1 R-433506 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 FRONTAGE IMPROVEMENTS DETAILS C3.2 7 1 NOT TO SCALE CEMENT CONCRETE CURBS 2 NOT TO SCALE CEMENT CONCRETE SIDEWALK Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - C N T R L - S U R F . d w g R-433507 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 FRONTAGE IMPROVEMENTS DETAILS C3.3 8 1 NOT TO SCALE CURB AND GUTTER 2 NOT TO SCALE TYPE C1B CONCRETE DRIVEWAY 3 NOT TO SCALE TRANVERSE PATCH WITH OVERLAY Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - C N T R L - S U R F . d w g R-433508 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 S0 0 ° 1 5 ' 5 9 " W 2 5 6 . 7 1 ' B I K E B I K E VAN B I K E W 14"FIR 16"FIR 24"FIR 12"FIR 20"FIR 16"FIR 30"FIR 16"FIR 177.5 L F 303.5 L F WF A3 WF A5 WF A7 WF A8 WF AA8 WF AA6 WF AA5 ROCK E R Y ROCKERY - - - - LS PV LS LS LS WF AA7 WF AA4 M WATE R V A L V E WATE R M A N H O L E EXIST I N G 1 2 " G V A S P H A L T ASPH A L T AS P H A L T AS P H A L T AS P H A L T GRAVEL ASPH A L T - SIDEW A L K 24" FIR 30" Fir 18" MAPLE 30" FIR WF A6 CATCH BASIN RIM 398.80 12" CONC NE 394.86 IE 12" CONC N 394.84 IE 12" CONC SW 394.91 IE CATCH BASIN RIM 399.93 12" CONC NE 395.33 IE 12" CONC SW 395.21 IE- > SB SIGNAL BOX SB TV EXIST I N G S T R E A M N63°5 7 ' 2 7 " E 1423. 1 4 ' ( M ) 1423. 2 1 ' ( S T ) 595.0 7 ' ( C ) 595.1 0 ' ( S T ) 828.0 7 ' ( C ) 828.1 1 ' ( S T ) S 2 6 ° 0 2 ' 3 3 " E 4 5 . 0 0 ' FOUND INVERTED NAIL IN CONCRETE POST, INCASED FOUND INVERTED NAIL IN CONCRETE POST, INCASED 48" CMP CULVERT 389.11 IE 8" CONCRETE CULVERT 393.56 IE CATCH BASIN RIM 400.13 12" CONC SW 397.30 IE CATCH BASIN RIM 400.78 12" CONC SW 397.38 IE 20' SEWER EASEMENT S0 ° 1 5 ' 5 9 " W 25 6 . 7 1 ' N89° 37' 58"W164.55' N0 ° 0 0 ' 2 5 " E 17 4 . 6 8 ' N63° 5 7 ' 2 7 " E 184.4 5 ' PROPOSED COMMERCIAL BUILDING NE SU N S E T B L V D 40.00' STREAM BUFFER DISCHARGE TO EXISTING STREAM PER HPA PERMIT NUMBER 2025-4-81+01 DETENTION CHAMBERS 400 39 6 397 3 9 7 3 9 8 399 401 401 397 39 8 39 9 FF: 399.50 PERVIOUS CONCRETE OR PERVIOUS PAVING PERVIOUS CONCRETE OR PERVIOUS PAVING FRENCH DRAIN FRENCH DRAIN 6.50' ROW DEDICATION FLOW LINE TO BE MAINTAINED PER MODIFICATION REQUEST ANTICIPATED HIGH WATER MARK = 392.05 1 C4.2 2 C4.2 CO #2 CO #1 CO #3 CB #4 CB #1 CO #4 CB #2 CB #3 CB #5 CO #6 CO #8 CO #7 IE: 396.00 6" (SE) IE: 392.58 12" (N) 48 LF 12" CPEP @ 1.04% 14 LF 12" CPEP @ 0.00% 43 LF 6" CPEP @ 2.33% 5 LF 6" CPEP @ 0.50% 21 LF 12" CPEP @ 1.37% 60 LF 6" CPEP @ 0.83% 19 LF 6" CPEP @ 0.50% 12 LF 6" CPEP @ 3.16% 103 L F 6 " C P E P @ 1 . 4 9 % 33 LF 6" CPEP @ 6.43% 97 LF 6" CPEP @ 0.50% 10 LF 6" CPEP @ 0.50% 3 C4.2 BIORETENTION POND CB #6 CB #7 27 LF 6" CPEP @ 0.50% PROPOSED MEDICAL OFFICE SHELL 5,200 SF FOOTPRINT 15 LF 12" CPEP @ 0.50% CB #8 CO #5 INSTALL FOOTING DRAIN ALONG WALL CONNECT WALL DRAIN INTO ROOF DRAINS CONNECT TRASH ENCLOSURE DOWNSPOUT TO BUILDING ROOF DRAIN LINE STORM STRUCTURE TABLE STRUCTURE NAME CB #1 54" TYPE 2 CONTROL STRUCTURE SOLID LID N 618.12 E 953.98 CB #2 NYLOPLAST DRAIN 30" SOLID LID N 611.60 E 866.55 CB #3 4'x6' BIOPOD SURFACE VAULT WITH INTERNAL BYPASS N 584.71 E 873.84 CB #4 48" TYPE 2 MH SOLID LID N 661.81 E 980.15 CB #5 TYPE 1 BEEHIVE GRATE N 628.11 E 991.20 CB #6 NYLOPLAST DRAIN 30" SOLID LID N 658.30 E 972.96 CB #7 NYLOPLAST DRAIN 30" SOLID LID N 629.70 E 946.88 CB #8 TYPE 1 SOLID LID N 649.26 E 988.22 CO #1 N 778.58 E 988.24 CO #2 N 733.37 E 895.69 CO #3 N 718.77 E 865.79 CO #4 N 621.39 E 865.67 CO #5 N 587.01 E 878.56 CO #6 N 710.04 E 1000.47 CO #7 N 650.10 E 1000.19 CO #8 N 631.44 E 1000.11 STRUCTURE DETAILS RIM = 398.05 IE = 393.08 (12" S) IE = 393.08 (12" NW) RIM = 397.78 IE = 394.23 (6" SE) IE = 394.64 (6" N) IE = 393.14 (24" NE) RIM = 394.97 IE = 394.40 (6" NE) RIM = 398.45 IE = 395.00 (6" NW) IE = 394.50 (12" SE) IE = 394.50 (12" SW) RIM = 397.90 IE = 394.86 (12" N) RIM = 398.44 IE = 394.40 (12" NE) IE = 393.14 (24" SW) IE = 393.14 (12" SE) RIM = 398.24 IE = 393.08 (12" SE) IE = 393.08 (12" SW) RIM = 398.33 IE = 394.57 (12" S) IE = 395.07 (6" E) IE = 394.57 (12" NW) RIM = 399.89 IE = 398.85 (6" SW) RIM = 399.82 IE = 397.32 (6" NE) IE = 397.32 (6" SW) RIM = 399.21 IE = 395.18 (6" NE) IE = 395.18 (6" S) RIM = 397.85 IE = 394.69 (6" S) IE = 394.69 (6" N) RIM = 397.66 IE = 394.37 (6" SW) IE = 394.37 (6" NW) RIM = 397.45 IE = 395.95 (6" S) RIM = 397.00 IE = 395.45 (6" N) IE = 395.45 (6" S) IE = 395.45 (6" W) RIM = 397.04 IE = 395.54 (6" N) CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N STORM DRAINAGE PLAN C4.1 9 VERTICAL DATUM = NORTH AMERICAN VERTICAL DATUM NAVD 88 (CITY OF RENTON) CITY OF RENTON SURVEY CONTROL POINT 2189 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY ELEVATION: 400.60' SITE NO.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH END OF 6' CYCLONE FENCE. ELEVATION: 396.77 BENCHMARK EDGE OF STREAM STREAM BUFFER STREAM BUFFER 1 C4.3 Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - S T R M . d w g 1 C4.5 REFER TO ARCHITECTURAL PLANS FOR DOWNSPOUT LOCATIONS 18" 12" TYP PERMEABLE GEOTEXTILE SEPARATION FABRIC 6" PERFORATED OR SLOTTED RIGID PVC PIPE 1-1/2" DRAIN ROCK 1 NOT TO SCALE FRENCH DRAIN 1 C4.1 1 C4.1 1 C4.4 1.ALL STORM LINES AND STRUCTURES ON-SITE ARE PRIVATE UNLESS NOTED OTHERWISE STORM NOTE R-433509 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 Surface Water Enginering jfarah 07/23/2025 385 390 395 400 405 385 390 395 400 405 10+00 FG FG 4 0 0 . 9 1 10+50 FG 3 9 9 . 5 0 FG 3 9 9 . 5 0 11+00 FG 3 9 9 . 4 3 FG 3 9 8 . 6 4 11+50 FG 3 9 8 . 2 5 FG 3 9 7 . 2 2 12+00 FG BIO-RETENTION POND 52.00' BUILDING MIN. 4.0' WIDE BERM EXISTING ROW BOUNDARY PROPOSED ROW BOUNDARY PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE STORMTECH DETENTION CHAMBERS 40' STREAM BUFFER RETAINING WALL 6" VERTICAL CURB BOTTOM OF ROCK: 392.00 BOTTOM OF CHAMBER: 392.75 385 390 395 400 405 385 390 395 400 405 20+00 FG 3 9 8 . 7 4 FG 3 9 8 . 3 8 20+50 FG 3 9 8 . 0 4 FG 21+00 FG 21+25 FG BIO-RETENTION POND EXISTING STREAM STORM OUTLET WITH OUTFALL PROTECTION IE: 392.58 RETAINING WALL MIN. 4.0' WIDE BERM PROPERTY LINE PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE STORMTECH DETENTION CHAMBERS HIGH WATER MARK = 392.05 10.00' 40' STREAM BUFFER 1.96' 14 LF 12" CPEP @ 0.00% CB #1, 54" TYPE 2 CONTROL STRUCTURE SOLID LID N: 618.12 E: 953.98 RIM: 398.05 IE: 393.08 12" (S) IE: 393.08 12" (NW) 48 LF 12" CPEP @ 1 . 0 4 % 6" VERTICAL CURB N: 629.70 E: 946.88 IE: 393.08 12" (SE) IE: 393.08 12" (SW) RIM: 398.24 CB #7, NYLOPLAST DRAIN 30" SOLID LID BOTTOM OF ROCK: 392.00 BOTTOM OF CHAMBER: 392.75 1.08' OF DEAD STORAGE OHWL 390 395 400 390 395 400 23+00 FG 3 9 7 . 8 6 FG 3 9 7 . 9 6 23+50 FG 3 9 8 . 5 8 FG 3 9 8 . 5 8 24+00 FG 3 9 8 . 5 1 FG 3 9 8 . 4 9 24+40 FG 3 9 8 . 5 3 CB #2, NYLOPLAST DRAIN 30" SOLID LID N: 611.60 E: 866.55 RIM: 397.78 IE: 394.23 6" (SE) IE: 394.64 6" (N) IE: 393.14 24" (NE) PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE STORMTECH DETENTION CHAMBERS CB #6, NYLOPLAST DRAIN 30" SOLID LID N: 658.30 E: 972.96 RIM: 398.44 IE: 394.40 12" (NE) IE: 393.14 24" (SW) IE: 393.14 12" (SE) VALLEY GUTTER BOTTOM OF ROCK: 392.00 BOTTOM OF CHAMBER: 392.75 1.08' OF DEAD STORAGE CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 SITE SECTIONS C4.2 10 1 SCALE: H:1"=20', V:1"=2' SITE SECTION 1 2 SCALE: H:1"=20', V:1"=2' SITE SECTION 2 3 SCALE: H:1"=20', V:1"=2' SITE SECTION 3 2 C4.5 2 C4.5 2 C4.5 Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - S T R M . d w g R-433510 8.00' OUTFALL PROTECTION 5 C4.9 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 Surface Water Enginering jfarah 07/23/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 STORM NOTES AND DETAILS C4.3 11 CB #3 0.0215 0.1083 1 NOT TO SCALE 4X6 BIOPOD SURFACE VAULT WITH INTERNAL BYPASS Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - S T R M . d w g R-433511 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 0.5'MIN. 12"Ø OUTLET PIPE RESTRICTOR PLATE W/ IE: 393.08IE: 393.08 RIM: 398.05 BOTTOM ORIFICE 0.650" NOTCH IE: 394.84 DESIGN WS: 396.08 WIDTH: 0.12'' OIL / FLOATABLE'S BAFFLE 12"Ø INLET PIPE ROUND COVER 24" BAFFLE 18" RISER PIPE SUPPORT 165°' 2' M I N . 2' M I N . CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 STORM NOTES AND DETAILS C4.4 12 1.METAL PARTS: CORROSION RESISTNAT. NON-GALVANIZED PARTS PREFERRED. GALVANIZED PIPE PARTS TO HAVE ASPHALT TREATMENT. 2.FRAME AND LADDER OR STEPS OFFSET SO: 2.1.CLEANOUT GATE IS VISIBLE FROM TOP. 2.2.CLIMB-DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. 3.PROVIDE AT LEAST ONE 3" X 0.090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM 3' VERTICAL SPACING) 4.REFER TO CITY OF RENTON FLOW CONTROL STRUCTURE STANDARD DETAIL FOR ADDITIONAL NOTES OUTLET STRUCTURE NOTES Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - S T R M . d w g 1 SCALE: 1"=2' 54-INCH CONTROL STRUCTURE 2 CITY OF RENTON FLOW CONTROL STRUCTURE R-433512 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 VAN WF A 3 WF A 5 WF A 7 WF A 8 WF A A 8 WF A A 6 WF A A 5 WF A A 1 ROCKERY WF A A 7 WF A A 4 WF A A 1 18" M A P L E 30" F I R WF A 6 WF AA 3 EXISTING STREAM 48" C M P C U L V E R T 389 . 1 1 I E N89 ° 3 7 ' 5 8 " W 164 . 5 5 ' 396 397 397 39 7 39 7 398 398 398 397 398 39 9 110.78' 25.85' STORM CHAMBERS REFERENCE MANUFACTURER PLAN FOR FULL CHAMBER DESIGN BIORETENTION CELL BOTTOM AREA: 478 SF BOT ELEV: 396.90 TOP ELEV: 397.90 104.76' 10.73' OUTFALL PROTECTION TO TERMINATE 2.0' PRIOR TO THE ORDINARY HIGH WATER MARK OF THE STREAM (TYP.) N 581.41 E 897.43 N 581.08 E 900.06 N 617.90 E 994.47 N 628.11 E 991.20N 609.59 E 964.64 INLET PROTECTION (TYP.) INLET PROTECTION (TYP.) TW: 395.53 TW: 397.90 TW: 397.90 TW: 397.90 TW: 397.90 TW: 396.66 TW: 397.83BW: 395.53 BW: 395.73 BW: 395.80 BW: 396.13 BW: 396.26 BW: 396.42 BW: 396.66 GRADE AT BACK OF CURB ALONG THE BIO-RETENTION POND TO BE SET AT TOP OF POND ELEVATION 39 8 398 398 398 BIOPOD CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 GRAPHIC SCALE 0 10 20 1" = 10 FEET 5 N STORM NOTES AND DETAILS C4.5 13 1 SCALE: 1" = 10' STORM LAYOUT 2 NOT TO SCALE STORMTECH CHAMBER SYSTEM ACCEPTABLE FILL MATERIALS: STORMTECH SC-800 CHAMBER SYSTEMS PLEASE NOTE: 1.THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE". 2.STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 6" (150 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR. 3.WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS. 4.ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION. 5.WHERE RECYCLED CONCRETE AGGREGATE IS USED IN LAYERS 'A' OR 'B' THE MATERIAL SHOULD ALSO MEET THE ACCEPTABILITY CRITERIA OUTLINED IN TECHNICAL NOTE 6.20 "RECYCLED CONCRETE STRUCTURAL BACKFILL". NOTES: 1.CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418, "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 2.SC-800 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 3.THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS. REFERENCE STORMTECH DESIGN MANUAL FOR BEARING CAPACITY GUIDANCE. 4.PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS. 5.REQUIREMENTS FOR HANDLING AND INSTALLATION: ·TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS. ·TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN 2”. ·TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT AS DEFINED IN SECTION 6.2.8 OF ASTM F2418 SHALL BE GREATER THAN OR EQUAL TO 550 LBS/FT/%. AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73° F / 23° C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR YELLOW COLORS. MATERIAL LOCATION DESCRIPTION AASHTO MATERIAL CLASSIFICATIONS COMPACTION / DENSITY REQUIREMENT D FINAL FILL: FILL MATERIAL FOR LAYER 'D' STARTS FROM THE TOP OF THE 'C' LAYER TO THE BOTTOM OF FLEXIBLE PAVEMENT OR UNPAVED FINISHED GRADE ABOVE. NOTE THAT PAVEMENT SUBBASE MAY BE PART OF THE 'D' LAYER. ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS. CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS.N/A PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND PREPARATION REQUIREMENTS. C INITIAL FILL: FILL MATERIAL FOR LAYER 'C' STARTS FROM THE TOP OF THE EMBEDMENT STONE ('B' LAYER) TO 15" (375 mm) ABOVE THE TOP OF THE CHAMBER. NOTE THAT PAVEMENT SUBBASE MAY BE A PART OF THE 'C' LAYER. GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES OR PROCESSED AGGREGATE. MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS LAYER. AASHTO M145¹ A-1, A-2-4, A-3 OR AASHTO M43¹ 3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10 BEGIN COMPACTIONS AFTER 12" (300 mm) OF MATERIAL OVER THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN 6" (150 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR PROCESSED AGGREGATE MATERIALS. ROLLER GROSS VEHICLE WEIGHT NOT TO EXCEED 12,000 lbs (53 kN). DYNAMIC FORCE NOT TO EXCEED 20,000 lbs (89 kN). B EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS FROM THE FOUNDATION STONE ('A' LAYER) TO THE 'C' LAYER ABOVE. CLEAN, CRUSHED, ANGULAR STONE OR RECYCLED CONCRETE5 AASHTO M43¹ 3, 357, 4, 467, 5, 56, 57 NO COMPACTION REQUIRED. A FOUNDATION STONE: FILL BELOW CHAMBERS FROM THE SUBGRADE UP TO THE FOOT (BOTTOM) OF THE CHAMBER. CLEAN, CRUSHED, ANGULAR STONE OR RECYCLED CONCRETE5 AASHTO M43¹ 3, 357, 4, 467, 5, 56, 57 PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE.2,3 33" (838 mm) 15" (375 mm) MIN* 6" (150 mm) MIN 6" (150 mm) MIN (SEE NOTE 3) D C B A *TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR, INCREASE COVER TO 21" (525 mm). 12" (300 mm) MIN 12" (300 mm) MIN51" (1295 mm)6" (150 mm) MIN EXCAVATION WALL (CAN BE SLOPED OR VERTICAL) PERIMETER STONE (SEE NOTE 4) SC-800 END CAP SUBGRADE SOILS (SEE NOTE 3) PAVEMENT LAYER (DESIGNED BY SITE DESIGN ENGINEER) 8' (2.4 m) MAX **THIS CROSS SECTION DETAIL REPRESENTS MINIMUM REQUIREMENTS FOR INSTALLATION. PLEASE SEE THE LAYOUT SHEET(S) FOR PROJECT SPECIFIC REQUIREMENTS. ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALL AROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - S T R M - D E T L . d w g 2 C4.5 1 C4.8 4.00' MIN. BERM R-433513 4 C4.94 C4.9 5 C4.9 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 STORM NOTES AND DETAILS C4.6 14 Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - S T R M - D E T L . d w g SC-800 ISOLATOR ROW PLUS DETAIL NTS SC-800 END CAP OPTIONAL INSPECTION PORT SC-800 CHAMBER ONE LAYER OF ADSPLUS625 WOVEN GEOTEXTILE BETWEEN FOUNDATION STONE AND CHAMBERS 5' (1.5 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS ELEVATED BYPASS MANIFOLD 24" (600 mm) HDPE ACCESS PIPE REQUIRED USE END CAP PART #: SC800EPE24BPC NYLOPLAST STORMTECH HIGHLY RECOMMENDS FLEXSTORM INSERTS IN ANY UPSTREAM STRUCTURES WITH OPEN GRATES SUMP DEPTH TBD BY SITE DESIGN ENGINEER (24" [600 mm] MIN RECOMMENDED) INSTALL FLAMP ON 24" (600 mm) ACCESS PIPE PART#: SC74024RAMP UNDERDRAIN DETAIL NTS A A B B SECTION A-A SECTION B-BNUMBER AND SIZE OF UNDERDRAINS PER SITE DESIGN ENGINEER 4" (100 mm) TYP FOR SC-310 & SC-160LP SYSTEMS 6" (150 mm) TYP FOR SC-800, DC-780, MC-3500, MC-4500 & MC-7200 SYSTEMS OUTLET MANIFOLD STORMTECH END CAP STORMTECH CHAMBERS STORMTECH END CAP DUAL WALL PERFORATED HDPE UNDERDRAIN ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE FOUNDATION STONE BENEATH CHAMBERS FOUNDATION STONE BENEATH CHAMBERS STORMTECH CHAMBER PART #STUB B C SC800EPE06TPC 6" (150 mm)21.4" (544 mm)--- SC800EPE06BPC ---0.9" (23 mm) SC800EPE08TPC 8" (200 mm)19.2" (488 mm)--- SC800EPE08BPC ---1.0" (25 mm) SC800EPE10TPC 10" (250 mm)17.0" (432 mm)--- SC800EPE10BPC ---1.2" (30 mm) SC800EPE12TPC 12" (300 mm)14.4" (366 mm)--- SC800EPE12BPC ---1.6" (41 mm) SC800EPE15TPC 15" (375 mm)11.3" (287 mm)--- SC800EPE15BPC ---1.7" (43 mm) SC800EPE18TPC 18" (450 mm)8.0" (203 mm)--- SC800EPE18BPC ---2.0" (51 mm) SC800EPE24BPC 24" (600 mm)---2.3" (58 mm) SC800EPE NONE SOLID END CAP NOTE: ALL DIMENSIONS ARE NOMINAL NOMINAL CHAMBER SPECIFICATIONS SIZE (W X H X INSTALLED LENGTH)51.0" X 33.0" X 85.4" (1295 mm X 838 mm X 2169 mm) CHAMBER STORAGE 50.6 CUBIC FEET (1.43 m³) MINIMUM INSTALLED STORAGE*81.0 CUBIC FEET (2.29 m³) WEIGHT 81.8 lbs.(37.1 kg) NOMINAL END CAP SPECIFICATIONS SIZE (W X H X INSTALLED LENGTH)46.5" X 32.6" X 10.5" (1181 mm X 828 mm X 267 mm) END CAP STORAGE 3.4 CUBIC FEET (0.09 m³) MINIMUM INSTALLED STORAGE**15.4 CUBIC FEET (0.43 m³) WEIGHT 15.7 lbs.(7.1 kg) * ASSUMES 6" (152 mm) STONE ABOVE, BELOW, AND BETWEEN CHAMBERS **ASSUMES 6" (152 mm) STONE ABOVE AND BELOW END CAPS, 6" (152 mm) BETWEEN ROWS, 12" (305 mm) BEYOND END CAPS PRE-CORED HOLES AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "BPC" PRE-CORED HOLES AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "TPC" SC-800 TECHNICAL SPECIFICATION NTS 90.6" (2301 mm) ACTUAL LENGTH 85.4" (2169 mm) INSTALLED LENGTH BUILD ROW IN THIS DIRECTION C B 51.0" (1295 mm) 33.0" (838 mm) 46.5" (1181 mm)12.2" (310 mm) OVERLAP NEXT CHAMBER HERE (OVER SMALL CORRUGATION) START END 32.6" (828 mm) 1 NOT TO SCALE STORMTECH ISOLATOR ROW DETAIL 2 NOT TO SCALE CHAMBER UNDERDRAIN 3 NOT TO SCALE CHAMBER SPECIFICATIONS R-433514 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 STORM NOTES AND DETAILS C4.7 15 Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - S T R M - D E T L . d w g NOTE: INSPECTION PORTS MAY BE CONNECTED THROUGH ANY CHAMBER CORRUGATION CREST. STORMTECH CHAMBER 8" NYLOPLAST UNIVERSAL INLINE DRAIN BODY (PART# 2708AG4IPKIT) OR TRAFFIC RATED BOX W/SOLID LOCKING COVER CONCRETE COLLAR ASPHALT OVERLAY FOR TRAFFIC APPLICATIONS 12" (300 mm) MIN WIDTH 8" (200 mm) MIN THICKNESS OF ASPHALT OVERLAYAND CONCRETE COLLAR 4" PVC INSPECTION PORT DETAIL (SC SERIES CHAMBER) NTS CONCRETE COLLAR / ASPHALT OVERLAY NOT REQUIRED FOR GREENSPACE OR NON-TRAFFIC APPLICATIONS 4" (100 mm) SDR 35 PIPE 4" (100 mm) INSERTA TEE TO BE CENTERED ON CORRUGATION CREST NYLOPLAST 8" LOCKING SOLID COVER AND FRAME NYLOPLAST DRAIN BASIN NTS NOTES 1.8-30" (200-750 mm) GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 2.12-30" (300-750 mm) FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3.DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS 4.DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS & HANCOR DUAL WALL) & SDR 35 PVC 5.FOR COMPLETE DESIGN AND PRODUCT INFORMATION: WWW.NYLOPLAST-US.COM 6.TO ORDER CALL: 800-821-6710 A PART #GRATE/SOLID COVER OPTIONS 8" (200 mm)2808AG PEDESTRIAN LIGHT DUTY STANDARD LIGHT DUTY SOLID LIGHT DUTY 10" (250 mm)2810AG PEDESTRIAN LIGHT DUTY STANDARD LIGHT DUTY SOLID LIGHT DUTY 12" (300 mm)2812AG PEDESTRIAN AASHTO H-10 STANDARD AASHTO H-20 SOLID AASHTO H-20 15" (375 mm)2815AG PEDESTRIAN AASHTO H-10 STANDARD AASHTO H-20 SOLID AASHTO H-20 18" (450 mm)2818AG PEDESTRIAN AASHTO H-10 STANDARD AASHTO H-20 SOLID AASHTO H-20 24" (600 mm)2824AG PEDESTRIAN AASHTO H-10 STANDARD AASHTO H-20 SOLID AASHTO H-20 30" (750 mm)2830AG PEDESTRIAN AASHTO H-20 STANDARD AASHTO H-20 SOLID AASHTO H-20 INTEGRATED DUCTILE IRON FRAME & GRATE/SOLID TO MATCH BASIN O.D. VARIOUS TYPES OF INLET AND OUTLET ADAPTERS AVAILABLE: 4-30" (100-750 mm) FOR CORRUGATED HDPE WATERTIGHT JOINT (CORRUGATED HDPE SHOWN) BACKFILL MATERIAL BELOW AND TO SIDES OF STRUCTURE SHALL BE ASTM D2321 CLASS I OR II CRUSHED STONE OR GRAVEL AND BE PLACED UNIFORMLY IN 12" (305 mm) LIFTS AND COMPACTED TO MIN OF 90% TRAFFIC LOADS: CONCRETE DIMENSIONS ARE FOR GUIDELINE PUPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED GIVING CONSIDERATION FOR LOCAL SOIL CONDITIONS, TRAFFIC LOADING & OTHER APPLICABLE DESIGN FACTORS ADAPTER ANGLES VARIABLE 0°- 360° ACCORDING TO PLANS 18" (457 mm) MIN WIDTH A AASHTO H-20 CONCRETE SLAB 8" (203 mm) MIN THICKNESS VARIABLE SUMP DEPTH ACCORDING TO PLANS [6" (152 mm) MIN ON 8-24" (200-600 mm), 10" (254 mm) MIN ON 30" (750 mm)] 4" (102 mm) MIN ON 8-24" (200-600 mm) 6" (152 mm) MIN ON 30" (750 mm) 12" (610 mm) MIN (FOR AASHTO H-20) INVERT ACCORDING TO PLANS/TAKE OFF 1 NOT TO SCALE NYLOPLAST DRAIN BASIN 2 NOT TO SCALE INSPECTION PORT R-433515 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 STORM NOTES AND DETAILS C4.8 16 BIO-RETENTION SOIL NOTES SEE CITY OF RENTON STANDARD PLAN 262 FOR BIORETENTION PLANTING AND SOIL NOTES 6" PONDING DEPTH 6" MIN FREEBOARD 18" MIN BIO-RETENTION SOIL, SEE NOTES BELOW PER PLAN 6" CURB 3' MIN. 3H:1V3H:1 V 4' BERM BIORETENTION PLANTING MIX AVOID COMPACTION OF NATIVE SUB-GRADE SOIL 3' MIN. 1.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE-CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON PLAN REVIEWER. 2.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE MOST RECENT "STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION" PREPARED BY W.S.D.O.T., AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS. 3.THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS WHICH ARE ON FILE IN THE DEPARTMENT OF PUBLIC WORKS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS OR SURFACE WATER UTILITY. 4.A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5.DATUM SHALL BE NAVD 88. UNLESS OTHERWISE APPROVED BY CITY OF RENTON DEPARTMENT OF PUBLIC WORKS. REFERENCE BENCHMARK AND ELEVATION ARE NOTED ON THE PLANS. 6.ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON-SITE EROSION HAS PASSED. 7.ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, SURFACE WATER UTILITY. 8.GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, SURFACE WATER UTILITY. 9.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-04 OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C", WITH THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95 % FOR PAVEMENT AND STRUCTURAL FILL AND 90% OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6" OVER AND UNDER P.V.C. PIPE. 10.GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE. 11.ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 12.OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT OF WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY OF RENTON ADMINISTRATOR, DEPARTMENT OF PLANNING/BUILDING/PUBLIC WORKS. 13.ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF 1 FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4"-8"/40%-70% PASSING; 2"-4" ROCK/30%-40% PASSING; AND -2" ROCK/10%-20% PASSING. 14.ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE DEPARTMENT OF DEVELOPMENT SERVICES, PLAN REVIEWER OR SURFACE WATER UTILITY. AN ACCURATELY DIMENSIONED CERTIFIED AS-BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY OF RENTON UPON COMPLETION. 15.ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMIT BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 16.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFT, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE AN APPROVED TRAFFIC CONTROL PLAN BY THE TRAFFIC ENGINEERING DIVISION OF THE DEPARTMENT OF PUBLIC WORKS. ALL SECTIONS OF THE W.S.D.O.T. STANDARD SPECIFICATIONS 1-07-23, TRAFFIC CONTROL, SHALL APPLY. SURFACE WATER DRAINAGE NOTES & SPECIFICATIONS 4" 0.5% 2" MIN. MIN. BUILDING FOUNDATION SEE STRUCTURAL DETAILS 6" PVC SDR 35 TYP. FINISHED GRADE 6" PVC CAP CUT HOLE TO ALLOW DOWNSPOUT TO PENETRATE WITH 1/8" CLEARANCE. ROOF DOWNSPOUT SEE ARCHITECTURAL DETAILS. PROVIDE FITTINGS AS REQUIRED COORDINATE DOWNSPOUT LOCATIONS WITH ARCHITECTURAL PLANS AND NOTCH FOOTINGS TO ACCOMMODATE ROOF DRAINS. FOOTING 6" BELOW GRADE AT DOCKS. REFER TO STRUCTURAL. 18" (MIN.) 2" (MIN.) 4" PERFORATED RIGID DRAIN PIPE REQUIRED AT LANDSCAPE AREAS (SURROUND WITH 1" ROCK) 12" MIN. SURFACE SEAL: NATIVE SOIL OR OTHER LOW PERMEABILITY MATERIAL. NOTES: DO NOT TIE ROOF DOWNSPOUTS TO FOOTING DRAIN. SURFACE SEAL TO CONSIST OF 12" OF LESS PERMEABLE, SUTIABLE SOIL. SLOPE AWAY FROM BUILDING. CONNECT TO DETENTION SYSTEM ·SOIL RETENTION. RETAIN, IN AN UNDISTURBED STATE, THE DUFF LAYER AND NATIVE TOPSOIL TO THE MAXIMUM EXTENT PRACTICABLE. IN ANY AREAS REQUIRING GRADING REMOVE AND STOCKPILE THE DUFF LAYER AND TOPSOIL ON SITE IN A DESIGNATED, CONTROLLED AREA, NOT ADJACENT TO PUBLIC RESOURCES AND CRITICAL AREAS, TO BE REAPPLIED TO OTHER PORTIONS OF THE SITE WHERE FEASIBLE. ·SOIL QUALITY. ALL AREAS SUBJECT TO CLEARING AND GRADING THAT HAVE NOT BEEN COVERED BY IMPERVIOUS SURFACE, INCORPORATED INTO A DRAINAGE FACILITY OR ENGINEERED AS STRUCTURAL FILL OR SLOPE SHALL, AT PROJECT COMPLETION, DEMONSTRATE THE FOLLOWING: 1.A TOPSOIL LAYER WITH A MINIMUM ORGANIC MATTER CONTENT OF 10% DRY WEIGHT IN BEDS, AND 5% ORGANIC MATTER CONTENT IN TURF AREAS, AND A PH FROM 6.0 TO 8.0 OR MATCHING THE PH OF THE UNDISTURBED SOIL. THE TOPSOIL LAYER SHALL HAVE A MINIMUM DEPTH OF EIGHT INCHES EXCEPT WHERE TREE ROOTS LIMIT THE DEPTH OF INCORPORATION OF AMENDMENTS NEEDED TO MEET THE CRITERIA. SUBSOILS BELOW THE TOPSOIL LAYER SHOULD BE SCARIFIED AT LEAST 4 INCHES WITH SOME INCORPORATION OF THE UPPER MATERIAL TO AVOID STRATIFIED LAYERS, WHERE FEASIBLE. 2.MULCH PLANTING BEDS WITH 2 INCHES OF ORGANIC MATERIAL 3.USE COMPOST AND OTHER MATERIALS THAT MEET THESE ORGANIC CONTENT REQUIREMENTS: 3.a.THE ORGANIC CONTENT FOR “PRE-APPROVED” AMENDMENT RATES CAN BE MET ONLY USING COMPOST MEETING THE COMPOST SPECIFICATION FOR BIORETENTION (REFER TO SECTION C.2.6) WITH THE EXCEPTION THAT THE COMPOST MAY HAVE UP TO 35% BIOSOLIDS OR MANURE. THE COMPOST MUST ALSO HAVE AN ORGANIC MATTER CONTENT OF 40% TO 65%, AND A CARBON TO NITROGEN RATIO BELOW 25:1. THE CARBON TO NITROGEN RATIO MAY BE AS HIGH AS 35:1 FOR PLANTINGS COMPOSED ENTIRELY OF PLANTS NATIVE TO THE PUGET SOUND LOWLANDS REGION. 3.b.CALCULATED AMENDMENT RATES MAY BE MET THROUGH USE OF COMPOSTED MATERIAL MEETING “A)” ABOVE; OR OTHER ORGANIC MATERIALS AMENDED TO MEET THE CARBON TO NITROGEN RATIO REQUIREMENTS, AND NOT EXCEEDING THE LIMITS IDENTIFIED IN TABLE 220-B, TESTING PARAMETERS, IN WAC 173-350-220. 4.THE RESULTING SOIL SHOULD BE CONDUCIVE TO THE TYPE OF VEGETATION TO BE ESTABLISHED. ·IMPLEMENTATION OPTIONS: THE SOIL QUALITY DESIGN GUIDELINES LISTED ABOVE CAN BE MET BY USING ONE OF THE METHODS LISTED BELOW: 1.LEAVE UNDISTURBED NATIVE VEGETATION AND SOIL, AND PROTECT FROM COMPACTION DURING CONSTRUCTION. 2.AMEND EXISTING SITE TOPSOIL OR SUBSOIL EITHER AT DEFAULT “PRE-APPROVED” RATES, OR AT CUSTOM CALCULATED RATES BASED ON TESTS OF THE SOIL AND AMENDMENT. 3.STOCKPILE EXISTING TOPSOIL DURING GRADING, AND REPLACE IT PRIOR TO PLANTING. 4.STOCKPILED TOPSOIL MUST ALSO BE AMENDED IF NEEDED TO MEET THE ORGANIC MATTER OR DEPTH REQUIREMENTS, EITHER AT A DEFAULT “PRE-APPROVED” RATE OR AT A CUSTOM CALCULATED RATE. 5.IMPORT TOPSOIL MIX OF SUFFICIENT ORGANIC CONTENT AND DEPTH TO MEET THE REQUIREMENTS. MORE THAN ONE METHOD MAY BE USED ON DIFFERENT PORTIONS OF THE SAME SITE. SOIL THAT ALREADY MEETS THE DEPTH AND ORGANIC MATTER QUALITY STANDARDS, AND IS NOT COMPACTED DOES NOT NEED TO BE AMENDED. SOIL AMENDMENT 1 NOT TO SCALE BIORETENTION CELL 2 NOT TO SCALE ROOF DOWNSPOUT AND FOOTING DRAIN Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - S T R M - D E T L . d w g 2.00' 1.00' HEIGHT WILL BE 2" - REFER TO PLANS FOR ELEVATION 8"4" CRUSED SURFACING TOP COURSE 6" COMPACTED SUBGRADE 95% MINIMUM PROCTOR CLASS 4000 CEMENT CONCRETE REFER TO PLANS FOR PAVEMENT SECTIONS 3 NOT TO SCALE CONCRETE VALLEY GUTTER 1.5' RETAINING WALL 6" BERM R-433516 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 STORM NOTES AND DETAILS C4.9 17 Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - S T R M - D E T L . d w g 1 BIORETENTION SECTION (NO UNDERDRAIN)2 BIORETENTION PLANTING - SECTION VIEW 3 BIORETENTION SOIL MIX & COMPOST & MULCH SPECIFICATIONS R-433517 OUTFALL PIP E EXISTING AND/OR PROPOSED GROUND 1' M I N . 4" MIN. FACE QUARRY ROCK 12" MIN. DEPTH (12"Ø PIPE) 18" MIN. DEPTH (15"-18"Ø PIPE) 24" MIN. ( 24"-36"Ø PIPE) * UNLESS OTHERWISE NOTED ON PLANS DI A . + 6 ' INLET/OUTFALL PIPE *8' 4 NOT TO SCALE INLET PROTECTION (AT BIORETENTION) OUTFALL PIP E EXISTING AND/OR PROPOSED GROUND 1' M I N . 4" DIA. ROUNDED ROCK 12" MIN. DEPTH (12"Ø PIPE) 18" MIN. DEPTH (15"-18"Ø PIPE) 24" MIN. ( 24"-36"Ø PIPE) * UNLESS OTHERWISE NOTED ON PLANS DI A . + 6 ' INLET/OUTFALL PIPE *8' 2"Ø PVC PIPE DRIVEN INTO GROUND PRIOR TO ROCK PLACEMENT TO ENSURE PLANTING SPACE FOR WILLOW STAKES. PIPES SPACED 1.5' ON CENTER. REFER TO ECOLOGIST SPECIFICATIONS. 5 NOT TO SCALE OUTFALL PROTECTION (AT CREEK) 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 S0 0 ° 1 5 ' 5 9 " W 2 5 6 . 7 1 ' B I K E B I K E VAN B I K E SANITARY SEWER MANHOLE RIM 400.93 8" CONC N 391.53 IE 12" CONC NE 390.88 IE 6" CONC S 391.82 IE 12" CONC SW 390.90 IE W 14"FIR 16"FIR 24"FIR 12"FIR 20"FIR 16"FIR 30"FIR 16"FIR SANITARY SEWER MANHOLE RIM 396.32 8" PVC S 393.35 IE 8" PVC SE 393.38 IE 8" PVC N 393.27 IE 303.5 L F WF A3 WF A5 WF A7 WF A8 WF AA8 WF AA6 WF AA5 ROCK E R Y ROCKERY - - - - LS PV LS LS LS WF AA7 WF AA4 M WATE R V A L V E WATE R M A N H O L E EXIST I N G 1 2 " G V A S P H A L T ASPH A L T AS P H A L T AS P H A L T AS P H A L T GRAVEL ASPH A L T - SIDEW A L K 24" FIR 30" Fir 18" MAPLE 30" FIR WF A6 SANITARY SEWER MANHOLE RIM 400.43 12" CONC NE 388.08 IE 8" PVC S 388.91 IE 12" CONC SW 388.08 IE SANITARY SEWER MANHOLE RIM 398.25 12" CONC NE 386.00 IE 12" CONC SW 385.95 IE SANITARY SEWER MANHOLE RIM 400.71 12" CONC NE 388.80 IE 12" CONC SW 388.61 IE - > SB SIGNAL BOX SB TV EXIST I N G S T R E A M N63°5 7 ' 2 7 " E 1423.1 4 ' ( M ) 1423. 2 1 ' ( S T ) 595.0 7 ' ( C ) 595.1 0 ' ( S T ) 828.0 7 ' ( C ) 828.1 1 ' ( S T ) S 2 6 ° 0 2 ' 3 3 " E 4 5 . 0 0 ' FOUND INVERTED NAIL IN CONCRETE POST, INCASED FOUND INVERTED NAIL IN CONCRETE POST, INCASED 20' SEWER EASEMENT S0 ° 1 5 ' 5 9 " W 25 6 . 7 1 ' N89° 37' 58"W164.55' N0 ° 0 0 ' 2 5 " E 17 4 . 6 8 ' N63° 5 7 ' 2 7 " E 184.4 5 ' PROPOSED COMMERCIAL BUILDING NE SU N S E T B L V D 40.00' STREAM BUFFER 400 39 6 397 397 3 9 8 399 397 39 8 39 9 FF: 399.50 1 + 0 0 2+ 0 0 2+ 3 1 STA:1+03.46, 0.00' 1-12"x10" TEE (MJxFL) 1-10" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK WET TAP WILL BE IN ACCORDANCE WITH COR STD PLAN 300.6. SEE STANDARD PLAN 300.5 ON SHEET C5.4 FOR CONNECTION DETAIL. EXISTING FIRE HYDRANT STA:2+16.34, 0.00' 1-10"x6" TEE (MJxFL) 1-6" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK FH ASSEMBLY PER COR STD PLAN 310.1, 310.2, 310.3 STA:2+16.34, 7.50' LT CENTER FIRE HYDRANT ASSEMBLY 4'X4' CONC PAD PER COR STD DTL 310.2 EXISTING DOMESTIC SERVICE LINE TO BE CUT AND CAPPED 1" DCVA FOR IRRIGATION STA:1+93.96, 0.00' 1-22.5° BEND (MJ) 1-CONC. THRUST BLOCK STA:1+94.92, 7.16' LT 1-FIRE DEPARTMENT CONNECTION 400 399 401 401 PROPOSED MEDICAL OFFICE SHELL 5,200 SF FOOTPRINT 3 9 7 398 398 398 397 6.50' ROW DEDICATION SSCO #4 RIM: 399.46 IE: 393.79 8" (W) IE: 393.79 8" (NE) SSCO #3 RIM: 399.41 IE: 392.42 8" (NW) IE: 392.42 8" (NE) SSCO #5 RIM: 399.38 IE: 391.90 8" (W) IE: 391.90 8" (E) IE: 391.90 8" (SE) SSCO #2 RIM: 399.33 IE: 393.80 8" (SW) IE: 393.80 8" (SE) SSCO #1 RIM: 398.26 IE: 394.51 8" (NW) SSCO #6 RIM: 398.23 IE: 390.65 8" (W) IE: 390.65 8" (E) INSTALL SEWER SERVICE IE: 390.39 8" (E) 6 LF 8" PVC @ 4.36% 35 LF 8" PVC @ 3.53% 5 LF 8" PVC @ 35.28% 2 LF 8" PVC @ 2.00% 26 LF 8" PVC @ 2.01% 69 LF 8 " P V C @ 2 . 0 0 % 36 LF 8" PVC @ 2.00% STA:2+13.34, 6.49' LT 1-PIV VALVE PER COR STD DTL 360.5 1" WATER SERVICE AND RPBA BACKFLOW DEVICE SHALL BE PROVIDED INSIDE THE BUILDING PER COR STD DETAIL 350.2 DDCVA FIRE BACKFLOW ASSEMBLY SHALL BE INSTALLED INSIDE THE BUILDING PER COR STD DETAIL 360.5. FIRE SERVICE LINES TO BE 4" DI CL 52. REFER TO FIRE PROTECTION NOTE ON SHEET C5.7 STA:2+21.28, 0.00' 1-10" POLYPIG STATION PER COR STD PLAN 300.7 STA:2+10.34, 6.50' LT 1" WATER SERVICE CONNECTION (BY CITY FORCES) PER COR STD PLAN 320.1 STA:1+82.04, 6.50' LT 1" IRRIGATION SERVICE CONNECTION PER COR STD PLAN 320.1 387 390 395 400 405 387 390 395 400 405 1+00 FG FG 1+50 FG FG 4 0 0 . 8 5 2+00 FG 3 9 9 . 1 1 FG 3 9 8 . 6 6 2+31.28 FG 3 9 8 . 6 1 PROPOSED ROW BOUNDARY EXISTING ROW BOUNDARY STA: 1+03.46 1-12"x10" TEE (MJxFL) 1-10" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK WET TAP WILL BE IN ACCORDANCE WITH COR STD PLAN 300.6. SEE STANDARD PLAN 300.5 ON SHEET C5.4 FOR CONNECTION DETAIL. STA: 2+16.34 1-10"x6" TEE (MJxFL) 1-6" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK FH ASSEMBLY PER COR STD PLAN 310.1, 310.2, 310.3 STA: 2+21.28 1-10" POLYPIG STATION PER COR STD PLAN 300.7 STA: 1+47.62 EXISTING 12" SEWER MAIN T.O.P: 389.29 EXISTING GRADE AT SECTION LINE PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE PROPOSED GRADE AT SECTION LINE STA: 1+55.75 EXISTING 12" STORM MAIN IE: 395.82 90 L F 8 " D . I . C L 5 2 5 LF 8" D.I. CL52 1.50' STA: 1+90.03 PROPOSED 6" STORM IE: 396.09 1.50' 7.2% EXISTING ROAD CENTERLINE -8 . 9 % -5. 9 % STA: 1+93.96 1-22.5° BEND (MJ) 1-CONC. THRUST BLOCK 22 LF 8" D.I. CL52 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N UTILITY PLAN C5.1 18 VERTICAL DATUM = NORTH AMERICAN VERTICAL DATUM NAVD 88 (CITY OF RENTON) CITY OF RENTON SURVEY CONTROL POINT 2189 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY ELEVATION: 400.60' SITE NO.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH END OF 6' CYCLONE FENCE. ELEVATION: 396.77 BENCHMARK EDGE OF STREAM STREAM BUFFER STREAM BUFFER 1 SCALE: H:1"=20', V:1"=2' SITE SECTION 4 Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - U T I L . d w g 3 C5.4 2 C5.7 1 C5.1 W-433501 S-433501 R-433518 WT R - 2 7 - 4 3 3 5 W W P - 2 7 - 4 3 3 5 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 IN AREAS OF FILL, NEW ROADWAY SUBGRADE SHALL BE FILLED AND COMPACTED BEFORE EXCAVATION FOR INSTALLATION OF NEW WATER MAIN (TYP) C5.6 AT MAIN BY CITY FORCES. CUT AND CAP PERMIT REQUIRED DROP-IN METER BY CITY FORCES. DROP-IN METER PERMIT REQUIRED DROP-IN METER BY CITY FORCES. DROP-IN METER PERMIT REQUIRED WATER UTILITY ABDOUL GAFOUR 07/25/2025 WASTEWATER UTILITY jstowell 07/28/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 SEWER NOTES AND DETAILS C5.2 19 1.ALL WORK AND WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. 2.THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT. AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN PUBLIC RIGHT OF WAY. 3.ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. 4.A PRE-CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5.CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7.PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8.A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9.THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS-BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 10.BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 11.OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON. 12.DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 13.ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON-SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 14.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 15.SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY. 16.IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE OR MUST HAVE MINIMUM 2’ DIAMETER CONCRETE RING POURED AT GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. SANITARY SEWER NOTES & SPECIFICATIONS 1 NOT TO SCALE SEWER CLEANOUT Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - U T I L - D E T L . d w g S-433502 W W P - 2 7 - 4 3 3 5 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 WASTEWATER UTILITY jstowell 07/28/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 SEWER NOTES AND DETAILS C5.3 20 1 NOT TO SCALE PIPE BEDDING FOR SANITARY SEWERS 2 NOT TO SCALE SIDE SEWER STUB INSTALLATION 3 NOT TO SCALE AIR TEST TABLE FOR SEWERS Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - U T I L - D E T L . d w g S-433503 W W P - 2 7 - 4 3 3 5 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 WASTEWATER UTILITY jstowell 07/28/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 WATER NOTES AND DETAILS C5.4 21 1 NOT TO SCALE WATER GENERAL NOTES 3 NOT TO SCALE TAPPING TEE Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - W A T R - D E T L . d w g 2 CONNECTION TO WATER MAIN TAPPING TEE AND VALVE W-433502 WT R - 2 7 - 4 3 3 5 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 WATER UTILITY ABDOUL GAFOUR 07/25/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 WATER NOTES AND DETAILS C5.5 22 1 NOT TO SCALE FIRE HYDRANT ASSEMBLY 2 NOT TO SCALE FIRE HYDRANT PAVEMENT MARKER 3 NOT TO SCALE 1 INCH WATER SERVICE Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - W A T R - D E T L . d w g W-433503 WT R - 2 7 - 4 3 3 5 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 and WATER UTILITY ABDOUL GAFOUR 07/25/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 WATER NOTES AND DETAILS C5.6 23 1 NOT TO SCALE CONCRETE BLOCKING FOR HORIZONTAL FITTINGS 3 NOT TO SCALE DOUBLE CHECK VALVE ASSEMBLY Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - W A T R - D E T L . d w g 2 POLYPIGGING NEW WATER MAINS W-433504 WT R - 2 7 - 4 3 3 5 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 WATER UTILITY ABDOUL GAFOUR 07/25/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 WATER NOTES AND DETAILS C5.7 24 1.ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2.THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AT (425) 430-7301. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY. 3.ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATES CALL 48-HOUR LOCATORS 800-424-5555. 4.AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AT THE PRE-CONSTRUCTION MEETING. 5.DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6.ALL WATERMAIN PIPE IS TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH-ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. 7.CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-87. CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/421/4-90. IF FITTINGS ARE 3 TO 12 INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL IN ACCORDANCE WITH EITHER ANSI/AWWA C110-A21.10-87 OR ANSI/AWWA C153/A21.53-94. THREE (3) INCH TO 12 INCH DIAMETER FITTINGS, WHICH HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS, SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.87 OR A COMBINATION OF ANSI/AWWA C110/A21.10.87 AND ANSI/AWWA C153/A21.53-94 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE WITH ANSI/AWWA C153/A21.53-94 AND THAT PORTION OF THE FITTING WITH FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH AWWA C110/A21.10-87. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53.53 OF ANSI/AWWA SECTION 10-4.3 OF ANSI/AWWA C110/A21.10-87 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 8.GATE VALVES SHALL BE IRON BODY, BRONZED-MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND O-RING STUFFING BOX (AWWA C500) OR OF RESILIENT SEATED TYPE (AWWA C509). VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380, M & H, OR APPROVED EQUAL. 9.FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR COMPRESSION TYPE (OPENING AGAINST PRESSURE) CONFORMING TO AWWA C-502-85 WITH A 6 INCH MECHANICAL JOINT INLET AND A MAIN VALVE OPENING (M.V.O.) OF 5-1/4 INCH, TWO 2-1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD THREADS 7-1/2 THREADS PER INCH AND ONE 4 INCH PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH, 60 DEGREES V. THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND ROOT DIAMETER 4.6263. HYDRANTS SHALL HAVE A 1-1/4 INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT). 10.THE TWO 2-1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND PROPORTIONS AS THE HYDRANT STEM NUT. CAPS SHALL BE FITTED WITH SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST PRESSURES. 11.THE 4 INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4 INCH SEATTLE THREAD X 5 INCH STORZ. STORZ ADAPTER SHALL BE FORGED AND/OR EXTRUDED 6061-T6 ALUMINUM ALLOY, HARDCOAT ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET SCREWS 180 DEGREES APART. STORZ FACE TO BE METAL, NO GASKET TO WEATHER. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8 INCH, COATED, STAINLESS STEEL, AIRCRAFT CABLE. 12.FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT NUMBER 43-655 SAFETY YELLOW OR APPROVED EQUAL. 13.PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. 14.FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAIL FOR FIRE HYDRANTS,LATEST REVISION. 15.ALL WATERMAINS 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATERMAIN 12 INCHES AND LARGER SHALL BE AT A MINIMUM OF 48 INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATERMAINS ARE TO BE LOWERED TO CLEAR. 16.ALL WATERMAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE CLEANED WITH PIPE CLEANING “PIGS” PRIOR TO DISINFECTION. THE “POLY PIGS” SHALL BE GIRARD INDUSTRIES AQUA SWAB-AS OR APPROVED EQUAL, 2 LB/CU. FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF “PIG” ONLY. 17.“PIGS” SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 18.ALL WATERMAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY OF RENTON STANDARD PLANS & SPECIFICATIONS 7-11.3(11). THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 19.ALL WATERMAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METERED/INJECTED IN ACCORDANCE WITH SECTION 7-11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED ABOVE. 20.A PRE-CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. 21.TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 22.IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 23.INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE CITY OF RENTON. 24.ALL CONNECTION TO EXISTING MAINS IS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS, WHICH MAY BE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE ON-SITE PRIOR TO CITY NOTIFICATIONS. 25.INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS-BUILT DRAWINGS. 26.CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW-OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 27.ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. 28.ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES. OIL MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 29.A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN 10 DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. * 30.FOR CITY PROJECTS SUCH AS TELEMETRY CONDUIT, THE PVC PIPE USED SHALL BE ALL CHEMICAL PROCESS LINES SHALL BE SCHEDULE 80 PVC PIPE. SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 PVC PIPE UNDER IMPROVED AREAS. WATER UTILITY NOTES & SPECIFICATIONS Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - W A T R - D E T L . d w g FIRE PROTECTION NOTES THE FIRE PROTECTION SYSTEM INCLUDING MATERIALS, SIZING, AND CONFIGURATION IS SUBJECT TO A CONTRACTOR PROVIDED DESIGN BY A FIRE PROTECTION ENGINEER, AND AS SUCH, THE FINAL DESIGN OF THE FIRE PROTECTION SYSTEM MAY DEVIATE FROM THE SYSTEM SHOWN. THE FIRE PROTECTION SYSTEM AS SHOWN FROM THE MAIN LINE TO THE CONNECTION AT THE BUILDING SPRINKLER IS INTENDED FOR LOCATION OF THE FIRE HYDRANTS AND FIRE DEPARTMENT CONNECTION ONLY. CONTRACTOR'S BID SHALL REFLECT THE CONDITIONS OF THE FIRE PROTECTION ENGINEER'S DESIGN. CONTRACTOR SHALL COMPLY WITH ALL NATIONAL FIRE PROTECTION ASSOCIATION REQUIREMENTS AS SET FORTH BY "NFPA 13", ITS AMENDMENTS, AND LOCAL REQUIREMENTS, INCLUDING BUT NOT LIMITED TO ACQUISITION OF ALL PERMITS. FIRE SPRINKLER NOTE WHERE THE UNDERGROUND WATER SUPPLY TEES OFF TO SERVE ONLY A FIRE SPRINKLER SYSTEM AND/OR FIRE HYDRANTS, A SEPARATE DETAILED PLAN MUST BE SUBMITTED AND APPROVED BY THE FIRE MARSHAL PRIOR TO INSTALLATION. 36 " - 4 2 " GRADE 2-1/2" FDC INLET WITH LOCKING FDC CAPS MANUFACTURED BY KNOX PRODUCTS TWO-WAY FREE STANDING CHROME- PLATED FIRE DEPARTMENT CONNECTION WITH 1" MIN. HIGH LETTERS "AUTO SPKR" METAL ADDRESS PLATE WELDED ON POST OR ATTACHED BY U-BOLT AND CHAIN, 24" MIN. ABOVE GRADE AND 1" MIN. HIGH LETTERS. 18" X 18" X 8" CONC. BLOCK 2 NOT TO SCALE FIRE DEPARTMENT CONNECTION 1 3-INCH AND LARGER DETECTOR DCVA INSIDE BUILDING INSTALL W-433505 WT R - 2 7 - 4 3 3 5 3 NOT TO SCALE FIRE HYDRANT SHEAR BLOCK 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 WATER UTILITY ABDOUL GAFOUR 07/25/2025 S0 0 ° 1 5 ' 5 9 " W 2 5 6 . 7 1 ' B I K E B I K E VAN B I K E W 14"FIR 16"FIR 24"FIR 12"FIR 20"FIR 16"FIR 30"FIR 16"FIR WF A3 WF A5 WF A7 WF A8 WF AA8 WF AA6 WF AA5 ROCK E R Y ROCKERY - - - - LS PV LS LS LS WF AA7 WF AA4 M WATE R V A L V E WATE R M A N H O L E EXIST I N G 1 2 " G V A S P H A L T ASPH A L T AS P H A L T AS P H A L T AS P H A L T GRAVEL ASPH A L T - SIDEW A L K 24" FIR 30" Fir 18" MAPLE 30" FIR WF A6 - > SB SIGNAL BOX SB TV EXIST I N G S T R E A M N63°5 7 ' 2 7 " E 1423.1 4 ' ( M ) 1423. 2 1 ' ( S T ) 595.0 7 ' ( C ) 595.1 0 ' ( S T ) 828.0 7 ' ( C ) 828.1 1 ' ( S T ) S 2 6 ° 0 2 ' 3 3 " E 4 5 . 0 0 ' FOUND INVERTED NAIL IN CONCRETE POST, INCASED FOUND INVERTED NAIL IN CONCRETE POST, INCASED 20' SEWER EASEMENT S0 ° 1 5 ' 5 9 " W 25 6 . 7 1 ' N89° 37' 58"W164.55' N0 ° 0 0 ' 2 5 " E 17 4 . 6 8 ' N63° 5 7 ' 2 7 " E 184.4 5 ' PROPOSED COMMERCIAL BUILDING NE SU N S E T B L V D 40' STREAM BUFFER PERVIOUS CONCRETE OR PERVIOUS PAVING PERVIOUS CONCRETE OR PERVIOUS PAVING 24' R50' R26' R10'R2' R4.5' 24' 9' (TYP.) 20' (TYP.) 9' 9' 5' 9' 20'R2' R2' R2' R2' BARRIER FREE PARKING (TYP.) 6' 5' 5' 10' 11' 10' 6' 5' 6' 8' 9' 9' 9' 9' 9' 10'R34' 24' X X EC FC EC X X NC VC VCO VC VCO VC NC EC EC FC EC FC EC FC EC X X X X REFER TO ARCHITECTURAL PLANS FOR TRASH ENCLOSURE CONCRETE VALLEY GUTTER PROPOSED MEDICAL OFFICE SHELL 5,200 SF FOOTPRINT X X WHEEL STOP (TYP.) VAN 9'9'9'5'9' 20' PROVIDE 12"x18" SIGN 1' BEHIND CURB. TYP. EACH STALL ACCESS PARKING SYMBOL PER WSDOT STD, PLAN M-24.60-04 NO PARKING SIGNAGE NO PARKING SIGNAGE CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N HORIZONTAL CONTROL & SURFACING PLAN C6.1 25 PAVING PLAN LEGEND EC EXTRUDED CURB VC VERTICAL CURB VCO 12" VERTICAL CURB OPENING FC FLUSH CURB NC NO CURB CHANGE CURB TYPE/END CURB ASPHALT CONCRETE PAVEMENT CONCRETE SIDEWALK PERVIOUS CONCRETE MAINTENANCE ACCESS ROAD. ALTERNATIVE SURFACE. GRASS PAVE OR SIMILAR. X Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - C N T R L - S U R F . d w g N GRAPHIC SCALE 0 5 10 1" = 5 FEET 1 NOT TO SCALE ACCESSIBLE PARKING 8 C6.2 5 C6.2 2 C6.2 2 C3.2 10 C6.2 7 C6.2 6 C6.2 1 C6.2 3 C4.8 R-433519 9 C6.2 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 SURFACING NOTES AND DETAILS C6.2 26 0.02 FT/FT COMPACTED SUBGRADE PER PLAN NOTES: 4" CEMENT CONCRETE SIDEWALK 2" CRUSHED SURFACING TOP COURSE 1.CEMENT CONCRETE SHALL BE CLASS B. 2.COMPACTION FOR CONCRETE WALKS TO BE 95% MAXIMUM DENSITY. 3.EXPANSION JOINTS CONSISTING OF 3/8" BY 4" PREMOLDED JOINT MATERIAL SHALL BE PLACED AT 15 FOOT INTERVALS, OR AS DIRECTED BY THE ARCHITECTURAL PLANS. 1/4" EDGE GROOVE SHALL BE PROVIDED AT JOINT EDGES. 4.SEE ARCHITECTURAL PLANS FOR JOINT PATTERNS. ATTACHMENT DETAIL ELEVATION PLAN NOTES: 1.THE NON-SHRINK GROUT USED TO ATTACH THE PRECAST CURB SHALL CONSIST OF 3:1 SAND AND CEMENT. GROUT TO A DEPTH OF 1" FROM THE TOP OF THE BUMPER. 2.LOCATIONS FOR WEEPHOLES, AND V-SLOTS SHALL BE IDENTIFIED ON THE DELIVERY ORDER DRAWINGS. 3.CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. 13/16" DIA. HOLES9" 6' 2" CLR (TYP) 6" 5" 2 1/2"2 1/2" 6" 10" #3 BARS (2) NON-SHRINK GROUT 18" MIN #6 BAR (2) #3 BARS (2) 3 NOT TO SCALE ONSITE CONCRETE SIDEWALK 9 NOT TO SCALE WHEEL STOP 2 NOT TO SCALE PAVEMENT SECTION 5 NOT TO SCALE EXTRUDED CURB Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - C N T R L - S U R F . d w g RAMP 3/ 1 6 " 1 5/8"2 3/8" 5/8" 7/16" 7/8"1 7/16" 3/4" 1 1/2" C D A B A B A B C D MIN MAX DETECTABLE WARNING PATTERN AREA SHALL BE YELLOW, IN COMPLIANCE WITH WSDOT STANDARD SPEC. 8-14.3(3) 1. ALTERNATIVE - SIGN MAY BE SECURELY MOUNTED TO BUILDING WALL. NOTES: 9" 3' M I N . 3" 12" STALLS ONLY GRADE PROPOSED VAN ACCESSIBLE 5' M A X . 18 " SCH. 40 2" DIA. G.I.P. MI N . 8"MIN. 2. 5 ' 4" CONCRETE 4 NOT TO SCALE DETECTABLE WARNING STRIP 8 NOT TO SCALE ADA PARKING SIGN 3" 6" NOTES: 1.ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. 2.THE CONTRACTOR SHALL EXPOSE EXISTING SUBGRADE, PROOF ROLL AND COMPACT TO 95%. IF YIELDING CONDITIONS ARE ENCOUNTERED, YIELDING MATERIALS SHALL BE REPLACED WITH IMPORTED STRUCTURAL FILL MATERIAL. THE DEPTH OF MATERIAL REPLACEMENT SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER. 12" COMPACTED SUBGRADE TO 95% CRUSHED SURFACING BASE COURSE PER WSDOT 9.03-9(3) HMA CLASS 1/2" PER WSDOT 9-03.8(1) AGGREGATE STORAGE RESERVOIR COURSE 12" 8" PERMEABLE CONCRETE SECTION INFILTRATING FILL FIRM AND UNYIELDING SUBGRADE VARIES NOTES: 1.ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. 2.THE CONTRACTOR SHALL EXPOSE EXISTING SUB-GRADE, PROOF ROLL AND COMPACT TO 90-92%. IF YIELDING CONDITIONS ARE ENCOUNTERED, YIELDING MATERIALS SHALL BE REPLACED WITH IMPORTED STRUCTURAL FILL MATERIAL. THE DEPTH OF MATERIAL REPLACEMENT SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER. 3.INFILTRATING FILL BENEATH PERMEABLE CONCRETE SECTION TO PROVIDE INFILTRATION RATES MEETING OR EXCEEDING THE EXISTING UNDERLYING SOILS. FILL MATERIAL TO BE APPROVED BY GROTECHNICAL ENGINEER. PERVIOUS CONCRETE NOTES: 1.A UNIQUE IDENTIFICATION NUMBER FOR THE MIX DESIGN THAT IS APPROVED FOR THE JOB MIX FORMULA (JMF). 2.PORTLAND CEMENT SHALL BE TYPE I, TYPE II, TYPE HI, TYPE IP, OR TYPE IS. 3.CEMENTITIOUS CONTENT: 480 POUNDS PER CUBIC YARD. 4.MIX TO INCORPORATE A HYDRATION STABILIZING ADMIXTURE 5.SYNTHETIC MICROFIBERS MAY BE UTILIZED AT THE MANUFACTURER'S RECOMMENDED DOSAGE RATE. 6.WATER/ CEMENT RATIO SHALL NOT EXCEED 0.35. 7.NO MORE THAN 25 PERCENT OF PORTLAND CEMENT IN THE MIX, BY WEIGHT, MAY BE REPLACED BY FLY ASH, GROUND GRANULATED BLAST FURNACE SLAG, OR A COMBINATION OF BOTH. 8.COARSE AGGREGATE SHALL CONFORM TO SECTION 9-03.1 (4), AASHTO GRADING NO. 8. INFILTRATION TESTING NOTE PRIOR TO BACKFILL OF INFILTRATING FILL OR PERMEABLE SURFACES, CONTRACTOR SHALL COORDINATE AND RECEIVE WRITTEN GEOTECHNICAL ENGINEER APPROVAL TO BACKFILL MATERIALS. GEOTECHNICAL ENGINEER TO PROVIDE CONFIRMATION OF ACCEPTABLE SUB-GRADE FOR INFILTRATION AND PROVIDE INFILTRATION TESTING AS NEEDED. INFILTRATION VERIFICATION REPORT SHALL BE PROVIDED TO ENGINEER AND CITY INSPECTOR. TESTING SHALL BE IN ACCORDANCE WITH REFERENCE 6-A OF THE 2021 KING COUNTY SURFACE WATER DESIGN MANUAL. FINAL VERIFICATION OF PERFORMANCE TO BE CONDUCTED BY GEOTECHNICAL ENGINEER. THE CITY MUST BE NOTIFIED OF THE SCHEDULED INFILTRATION TESTING AT LEAST 2 WORKING DAYS IN ADVANCE OF THE TEST. 10 NOT TO SCALE PERMEABLE CONCRETE SECTION – ” ” ” – 7 NOT TO SCALE GRASSPAVE 1/4" EDGED GROOVE 7 3/4" 1" R 6" 1' - 4 " 1/ 2 " 5 1/2" NOTE CONSTRUCTION SHALL CONFORM TO WSDOT SPEC. 8-04.3 FINISH GROUND GRADE PAVEMENT 6 NOT TO SCALE FLUSH CURB NOTE CONSTRUCTION SHALL CONFORM TO WSDOT SPECIFICATION 8-04.3. FINISH GRADE AT SIDEWALKS 12 " 6" PAVEMENT 1 NOT TO SCALE VERTICAL CURB R-433520 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 S0 0 ° 1 5 ' 5 9 " W 2 5 6 . 7 1 ' B I K E B I K E VAN B I K E SANITARY SEWER MANHOLE RIM 400.93 8" CONC N 391.53 IE 12" CONC NE 390.88 IE 6" CONC S 391.82 IE 12" CONC SW 390.90 IE W 14"FIR 16"FIR 24"FIR 12"FIR 20"FIR 16"FIR 30"FIR 16"FIR 177.5 L F SANITARY SEWER MANHOLE RIM 396.32 8" PVC S 393.35 IE 8" PVC SE 393.38 IE 8" PVC N 393.27 IE 303.5 L F WF A3 WF A5 WF A7 WF A8 WF AA8 WF AA6 WF AA5 ROCK E R Y ROCKERY - - - - LS PV LS LS LS WF AA7 WF AA4 M WATE R V A L V E WATE R M A N H O L E EXIST I N G 1 2 " G V A S P H A L T ASPH A L T AS P H A L T AS P H A L T AS P H A L T GRAVEL ASPH A L T - SIDEW A L K 24" FIR 30" Fir 18" MAPLE 30" FIR WF A6 CATCH BASIN RIM 398.80 12" CONC NE 394.86 IE 12" CONC N 394.84 IE 12" CONC SW 394.91 IE SANITARY SEWER MANHOLE RIM 400.43 12" CONC NE 388.08 IE 8" PVC S 388.91 IE 12" CONC SW 388.08 IE CATCH BASIN RIM 399.93 12" CONC NE 395.33 IE 12" CONC SW 395.21 IE SANITARY SEWER MANHOLE RIM 398.25 12" CONC NE 386.00 IE 12" CONC SW 385.95 IE SANITARY SEWER MANHOLE RIM 400.71 12" CONC NE 388.80 IE 12" CONC SW 388.61 IE - > SB SIGNAL BOX SB TV EXIST I N G S T R E A M N63°5 7 ' 2 7 " E 1423.1 4 ' ( M ) 1423. 2 1 ' ( S T ) 595.0 7 ' ( C ) 595.1 0 ' ( S T ) 828.0 7 ' ( C ) 828.1 1 ' ( S T ) S 2 6 ° 0 2 ' 3 3 " E 4 5 . 0 0 ' FOUND INVERTED NAIL IN CONCRETE POST, INCASED FOUND INVERTED NAIL IN CONCRETE POST, INCASED 48" CMP CULVERT 389.11 IE 8" CONCRETE CULVERT 393.56 IE CATCH BASIN RIM 400.13 12" CONC SW 397.30 IE CATCH BASIN RIM 400.78 12" CONC SW 397.38 IE 20' SEWER EASEMENT NE SU N S E T B L V D 40.00' STREAM BUFFER DETENTION CHAMBERS FRENCH DRAIN FRENCH DRAIN 6.50' ROW DEDICATION PROPOSED MEDICAL OFFICE SHELL 5,200 SF FOOTPRINT1 2 3 4 5 6 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N COMPOSITE UTILITY PLAN C7.1 27 Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - C O M P - U T I L . d w g PROP. 6" STORM IE= 396.59 PROP 1" WATER T.O.P= 395.09 1.5' MIN UTILITY CROSSING 2 PROP. 6" STORM IE= 396.42 PROP 8" SEWER T.O.P= 394.46 1.96' 3 PROP. 6" STORM IE= 396.66 PROP FIRE WATER T.O.P= 395.16 1.5' MIN 1 PROP. 6" STORM IE= 395.03 PROP 8" SEWER T.O.P= 391.60 3.43' 5 PROP. 6" STORM IE= 395.85 PROP 8" SEWER T.O.P= 394.31 1.54' 6 PROP. 6" STORM IE= 396.09 PROP 10" WATER T.O.P= 394.59 1.5' 4 W-433506 S-433504 R-433521 WT R - 2 7 - 4 3 3 5 W W P - 2 7 - 4 3 3 5 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 WASTEWATER UTILITY jstowell 07/28/2025 S0 0 ° 1 5 ' 5 9 " W 2 5 6 . 7 1 ' B I K E B I K E VAN B I K E W 14"FIR 16"FIR 24"FIR 12"FIR 20"FIR 16"FIR 30"FIR 16"FIR 303.5 L F WF A3 WF A5 WF A7 WF A8 WF AA8 WF AA6 WF AA5 ROCK E R Y - - - - LS PV LS LS LS WF AA7 WF AA4 M WATE R V A L V E WATE R M A N H O L E EXIST I N G 1 2 " G V A S P H A L T ASPH A L T GRAVEL ASPH A L T - SIDEW A L K 24" FIR 30" Fir 18" MAPLE 30" FIR WF A6 > SB SIGNAL BOX SB TV EXIST I N G S T R E A M N63°5 7 ' 2 7 " E 1423. 1 4 ' ( M ) 1423. 2 1 ' ( S T ) 595.0 7 ' ( C ) 595.1 0 ' ( S T ) S 2 6 ° 0 2 ' 3 3 " E 4 5 . 0 0 ' 20' SEWER EASEMENT S0 ° 1 5 ' 5 9 " W 25 6 . 7 1 ' N89° 37' 58"W164.55' N0 ° 0 0 ' 2 5 " E 17 4 . 6 8 ' N63° 5 7 ' 2 7 " E 184.4 5 ' 40.00' STREAM BUFFER 20.00' GRASS-PAVE OR APPROVED EQUAL 20.00' 20.00' 40.00' R38.00' PROPOSED MEDICAL OFFICE SHELL 5,200 SF FOOTPRINT 9.50' 15.50' R61.00' S0 0 ° 1 5 ' 5 9 " W 2 5 6 . 7 1 ' B I K E B I K E VAN B I K E W 14"FIR 16"FIR 24"FIR 12"FIR 20"FIR 16"FIR 30"FIR 16"FIR 303.5 L F WF A3 WF A5 WF A7 WF A8 WF AA8 WF AA6 WF AA5 ROCK E R Y - - - - LS PV LS LS LS WF AA7 WF AA4 M WATE R V A L V E WATE R M A N H O L E EXIST I N G 1 2 " G V A S P H A L T ASPH A L T ASPH A L T SIDEW A L K 24" FIR 30" Fir 18" MAPLE 30" FIR WF A6 > SB SIGNAL BOX SB TV EXIST I N G S T R E A M N63°5 7 ' 2 7 " E 1423. 1 4 ' ( M ) 1423. 2 1 ' ( S T ) 595.0 7 ' ( C ) 595.1 0 ' ( S T ) 20' SEWER EASEMENT S0 ° 1 5 ' 5 9 " W 25 6 . 7 1 ' N89° 37' 58"W164.55' N0 ° 0 0 ' 2 5 " E 17 4 . 6 8 ' N63° 5 7 ' 2 7 " E 184.4 5 ' GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N NE SU N S E T B L V D 20.00' 20.00' 20.00' CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 GARBAGE TRUCK TURNING EXHIBIT C8.1 28 1 TRUCK TURNING - ENTERING SITE 2 TRUCK TURNING - EXITING SITE NE SU N S E T B L V D R43.00' Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - V E H I C L E - T R A C K I N G . d w g NOTES: GARBAGE TRUCK FOR ILLUSTRATION PURPOSES ONLY. GARBAGE TRUCKS WILL BE FRONT LOAD. R-433522 50.00' 13.00' 13'x50' AREA TO BE FREE FROM OVERHEAD OBSTRUCTIONS TO A HEIGHT OF AT LEAST 25' 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 S0 ° 1 5 ' 5 9 " W 25 6 . 7 1 ' N89° 37' 58"W164.55' N0 ° 0 0 ' 2 5 " E 17 4 . 6 8 ' N63° 5 7 ' 2 7 " E 184.4 5 ' 400 397 3 9 8 399 401 401 397 39 8 39 9 FF: 399.50 S0 0 ° 1 5 ' 5 9 " W 2 5 6 . 7 1 ' B I K E B I K E VAN B I K E 14"FIR 16"FIR 24"FIR 12"FIR 20"FIR 16"FIR 30"FIR 16"FIR 177.5 L F 303.5 L F WF A3 WF A5 WF A7 WF A8 WF AA8 WF AA6 WF AA5 ROCK E R Y ROCKERY - - - - - 6' CYC L O N E F E N C E LS PV LS LS LS WF AA7 WF AA4 M WATE R V A L V E WATE R M A N H O L E EXIST I N G 1 2 " G V A S P H A L T ASPH A L T AS P H A L T AS P H A L T AS P H A L T GRAVEL ASPH A L T - SIDEW A L K 24" FIR 30" Fir 18" MAPLE 30" FIR WF A6 CATCH BASIN RIM 398.80 12" CONC NE 394.86 IE 12" CONC N 394.84 IE 12" CONC SW 394.91 IE CATCH BASIN RIM 399.93 12" CONC NE 395.33 IE 12" CONC SW 395.21 IE- > SB SIGNAL BOX SB TV EXIST I N G S T R E A M N63°5 7 ' 2 7 " E 1423. 1 4 ' ( M ) 1423. 2 1 ' ( S T ) 595.0 7 ' ( C ) 595.1 0 ' ( S T ) S26°02 ' 3 3 " E 4 5 . 0 0 ' CATCH BASIN RIM 400.13 12" CONC SW 397.30 IE CATCH BASIN RIM 400.78 12" CONC SW 397.38 IE 20' SEWER EASEMENT W FOUND INVERTED NAIL IN CONCRETE POST, INCASED 48" CMP CULVERT 389.11 IE 8" CONCRETE CULVERT 393.56 IE W 303.5 L F WF A3 WF A5 WF A7 WF A8 WF AA8 WF AA6 WF AA5 ROCK E R Y ROCKERY GUAR D R A I L - - - - - GUAR D R A I L 6' CYC L O N E F E N C E LS PV LS LS LS WF AA7 WF AA4 M ---- WATE R V A L V E WATE R M A N H O L E A S P H A L T ASPH A L T AS P H A L T AS P H A L T AS P H A L T GRAVEL ASPH A L T - CURB D R O P SIDEW A L K 24" FIR WF A6 - > SB SIGNAL BOX SB TV EXIST I N G S T R E A M 20 ' S E W E R E A S E M E N T 21" FIR COMMON NAMEBOTANICAL NAME TREES SIZE & SPACING PLANT LEGEND SHRUBS MYRICA CALIFORNICA PACIFIC WAX MYRTLE 3 GALLON, 6' O.C. SPACING QTY CERCIDIPHYLLUM JAPONICUM KATSURA TREE 1.5" CALIPER, 5' GRAFT RIBES SANGUINEUM CORNUS SERICEA 'KELSEYI'KELSEY DOGWOOD GROUNDCOVERS ARCTOSTAPHYLOS UVA-URSI VANCOUVER JADE KINNIKINNICK 3 MIN. 18" HT., 4' O.C. SPACING STYRAX JAPONICUS JAPANESE SNOWBELL 1.5" CALIPER, 5' GRAFTS GAULTHERIA SHALLON SALAL 1 GALLON, 30" O.C. SPACING RHODODENDRON ‘PURPLE GEM’PURPLE GEM AZALEA MIN. 18" HT., 3' O.C. SPACING RED FLOWERING CURRANT HAMAECYPARIS OBTUSA 'GRACILIS'6' HT., 4' O.C. SPACING PURPLE ROCK ROSECISTUS X PURPUREA+ HYDROSEED BY COUNTRY GREEN TURF FARM PERENNIAL RYEGRASS FINE FESCUE 80% 20%8 LBS PER 1000 SQ. FT. MIN. 18" HT., 4' O.C. SPACING 1 GALLON, 30" O.C. SPACING 6 2 14 19 32 48 103 388 8 CAREX OBNUPTA SLOUGH SEDGE 1 GALLON, 2' O.C. SPACING170 S S S S + + + + WESTERN RED CEDARTHUJA PLICATA 6'-8' HEIGHT, 3' O.C SPACING DOUGLAS FIRPSEUDOTSUGA MENZIESII 6'-8' HEIGHT, 5' O.C SPACING9 8C F F F + + + + + + + SKYROCKET JUNIPERJUNIPERUS SCOPULORUM 'SKYROCKET'30 C C C C 6'-8' HEIGHT, 3' O.C SPACING MIN. 18" HT., 3' O.C. SPACING POLYSTICHUM MUNITUM SWORD FERN71 1 GALLON, 3' O.C. SPACING + + + ACER CIRCINATUM 'PACIFIC FIRE'PACIFIC FIRE VINE MAPLE 2" CALIPER, SPACING PER PLAN3 + + S S C F F C ++ + + + + ++ ++ ++ + + TALL SLENDER HINOKI CYPRESS + + EX. 30" FIR TO REMAIN EX. 18" MAPLE TO REMAIN EX. 27" FIR TO REMAIN EX. 29" FIR TO BE REMOVED SEE ARBORIST REPORT FOR ADDITIONAL INFORMATION C C TREE PROTECTION FENCING, SEE DETAIL 1/L1.00 X TREE PROTECTION FENCING, SEE DETAIL 1/L1.00 TREE PROTECTION FENCING, SEE DETAIL 1/L1.00 F F F F F SEE STREAM STUDY AND BUFFER MITIGATION PLAN FOR BUFFER ENHANCEMENT PLANTING PLAN AND NOTES, AND ALSO LOCATIONS OF SPLIT RAIL FENCING AND NGPA SIGNAGE. FDC FIRE HYDRANT LANDSCAPE NOTES AND SOIL QUALITY 1.LANDSCAPE AREAS SHOULD BE DEEP-TILLED TO A DEPTH OF AT LEAST TWELVE (12) INCHES TO FACILITATE DEEP WATER PENETRATION AND SOIL OXYGENATION. PROVIDE SOIL AMENDMENTS ENCOURAGED TO IMPROVE WATER DRAINAGE, MOISTURE PENETRATION OR WATER-HOLDING CAPACITY. FOR ALL NEWLY LANDSCAPED AREAS ORGANIC MATTER SHOULD BE INCORPORATED TO A DEPTH OF FOUR (4) TO SIX (6) INCHES TO FACILITATE DEEP WATER PENETRATION AND SOIL OXYGENATION. 2.CONTRACTOR SHALL PROVIDE 9" DEPTH IMPORTED TOPSOIL AT ALL LANDSCAPE PLANTING AREAS. 3.IMPORTED TOPSOIL SHALL BE 3-WAY MIX. 4.CONTRACTOR SHALL PROVIDE 2" DEPTH FINE COMPOST MULCH THROUGHOUT LANDSCAPE PLANTING AREAS. CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIALS FOR A PERIOD OF (1) ONE YEAR AFTER APPROVAL BY OWNER OR OWNER'S REPRESENTATIVE. 5. TREES PLANTED FIVE FEET OR LESS FROM PAVED SURFACES SHALL BE PLANTED WITH ROOT CONTROL BARRIER.6. TREE PROTECTION FENCING1 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS SUNSET HIGHLANDS RENTON PROJECT AHBL JOB #2230621.10 32 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 2111 South C Street, Tacoma, WA 98402 253-678-4173 | Eric@LyonLA.com 1 1 29 1 1 SUNSET MEDICAL OFFICE BUILDING 34 CONSTRUCTION FOR DEVELOPMENT ENGINEERING HHuynh 07/21/2025 amorganroth 07/22/2025 CURRENT PLANNING COMMON NAMEBOTANICAL NAME TREES SIZE & SPACING PLANT LEGEND SHRUBS MYRICA CALIFORNICA PACIFIC WAX MYRTLE 3 GALLON, 6' O.C. SPACING QTY CERCIDIPHYLLUM JAPONICUM KATSURA TREE 1.5" CALIPER, 5' GRAFT RIBES SANGUINEUM CORNUS SERICEA 'KELSEYI'KELSEY DOGWOOD GROUNDCOVERS ARCTOSTAPHYLOS UVA-URSI VANCOUVER JADE KINNIKINNICK 3 MIN. 18" HT., 4' O.C. SPACING STYRAX JAPONICUS JAPANESE SNOWBELL 1.5" CALIPER, 5' GRAFTS GAULTHERIA SHALLON SALAL 1 GALLON, 30" O.C. SPACING RHODODENDRON ‘PURPLE GEM’PURPLE GEM AZALEA MIN. 18" HT., 3' O.C. SPACING RED FLOWERING CURRANT HAMAECYPARIS OBTUSA 'GRACILIS'6' HT., 4' O.C. SPACING PURPLE ROCK ROSECISTUS X PURPUREA+ HYDROSEED BY COUNTRY GREEN TURF FARM PERENNIAL RYEGRASS FINE FESCUE 80% 20%8 LBS PER 1000 SQ. FT. MIN. 18" HT., 4' O.C. SPACING 1 GALLON, 30" O.C. SPACING 6 2 14 19 32 48 103 388 8 CAREX OBNUPTA SLOUGH SEDGE 1 GALLON, 2' O.C. SPACING170 WESTERN RED CEDARTHUJA PLICATA 6'-8' HEIGHT, 3' O.C SPACING DOUGLAS FIRPSEUDOTSUGA MENZIESII 6'-8' HEIGHT, 5' O.C SPACING9 8C F SKYROCKET JUNIPERJUNIPERUS SCOPULORUM 'SKYROCKET'30 6'-8' HEIGHT, 3' O.C SPACING MIN. 18" HT., 3' O.C. SPACING POLYSTICHUM MUNITUM SWORD FERN71 1 GALLON, 3' O.C. SPACING ACER CIRCINATUM 'PACIFIC FIRE'PACIFIC FIRE VINE MAPLE 2" CALIPER, SPACING PER PLAN3 TALL SLENDER HINOKI CYPRESS PLANT IMAGES CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS SUNSET HIGHLANDS RENTON PROJECT AHBL JOB #2230621.10 32 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 2111 South C Street, Tacoma, WA 98402 253-678-4173 | Eric@LyonLA.com 30 1 SUNSET MEDICAL OFFICE BUILDING 34 CONSTRUCTION FOR DEVELOPMENT ENGINEERING HHuynh 07/21/2025 amorganroth 07/22/2025 CURRENT PLANNING SCALE: 1" = 1'-0" CONIFER PLANTING DETAIL COVER SOIL LOOSENED AREA WITH 2" MULCH. KEEP MULCH 3" AWAY FROM TREE TRUNK SOIL BACKFILL (SEE SPECS) PLACE ROOTBALL ON SOLID SOIL REMOVE BURLAP FROM TOP 12 OF ROOTBALL TILL COMPACTED SUBGRADE AS SPECIFIED DIG THE PLANTING PIT AT LEAST TWICE THE SIZE OF THE ROOTBALL PLACE TOP OF ROOTBALL 1" ABOVE LEVEL GROWING IN NURSERY NOTES: 1. FERTILIZE & WATER AS SPECIFIED FOLLOWING PLANTING. 2. SEE SPECS FOR ADDITIONAL INFORMATION 3. SEE STAKING DETAILS. SCALE: NTS SCALE: 3/4" = 1'=0" DECIDUOUS TREE PLANTING DETAIL PLACE ROOTBALL ON SOLID SOIL NOTE: 1. FERTILIZE AND WATER AS SPECIFIED FOLLOWING PLANTING. 2. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3. SEE STAKING DETAILS SPECIFIED TOPSOIL DIG THE PLANTING PIT AT LEAST 2 TIMES THE SIZE OF THE ROOTBALL COVER SOIL LOOSENED AREA WITH 2" BARK MULCH. KEEP MULCH 3" FROM TREE TRUNK STRONG STOUT STEMS AND BUDS ROTOTILL COMPACTED SUBGRADE AS SPECIFIED WIDE BRANCH ATTACHMENT REMOVE BURLAP FROM TOP HALF OF ROOTBALL SCALE: NTS SCALE: 3/4" = 1'=0" DECIDUOUS TREE STAKING DETAIL TO B O T T O M B R A N C H E S STAKE TO PENETRATE 12" MIN. BELOW BOTTOM OF PLANTING PIT 1' 2" Ø LODGE POLE STAKE. PLACE OUTSIDE ROOTBALL (2) 1" CHAIN-LOCK TREE TIES SCALE: NTS SCALE: 1/2" = 1'-0" SHRUB PLANTING DETAIL FG SPREAD ROOTS OF BASE ROOT PLANTS OUT OVER CONE OF HAND-FIRMED TOPSOIL CONE OF HAND-FIRMED TOPSOIL FOR BALL & BURLAP PLANTS NOTES: 1. USE PLANT STARTER SOLUTION DURING PLANTING OPERATION. FEED AS SPECIFIED. 2. SHRUBS SHALL BEAR SAME RELATION TO FINISHED GRADE AS IT BORE TO PREVIOUS EXISTING GRADE. TOP OF ROOTBALL SHALL BE 1" ABOVE FINISHED GRADE SAUCER TOPSOIL BACKFILL (SEE SPECS) REMOVE BURLAP FROM TOP 12 OF ROOT BALL 2" MULCH 3" M I N 18 " M I N 6" 12" MIN SCALE: NTS SCALE: 1" = 1'-0" GROUNDCOVER PLANTING DETAIL 6" 6" 1 FERTILIZER TABLET SPECIFIED TOPSOIL MULCH, AS SPECIFIED SCALE: NTS EQ. 1. 5 x SP R E A D EQ. BACK OF CURB OR LANDSCAPE BED EDGE GROUNDCOVERS, TYP NOTE: 1.ALL GROUNDCOVER SHALL BE PLANTED AT EQUAL TRIANGULAR SPACING AS PER PLAN, UNLESS SHOWN OTHERWISE 2.SET GROUNDCOVER BACK FROM CURB OR WALKWAY AT LEAST 1-1/2 TIMES THE SPREAD OF SUCH GROUNDCOVER 1 2 3 4 5 6SCALE: 1" = 1'-0" CONIFER TREE STAKING 2/ 3 H E I G H T O F T R E E 2" Ø LODGE POLE STAKE. PLACE OUTSIDE ROOTBALL 1" CHAIN LOCK TREE TIE 3 ' M I N 45°-60° 8 "M I N SCALE: NTS CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS SUNSET HIGHLANDS RENTON PROJECT AHBL JOB #2230621.10 32 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 2111 South C Street, Tacoma, WA 98402 253-678-4173 | Eric@LyonLA.com 31 SUNSET MEDICAL OFFICE BUILDING 34 CONSTRUCTION FOR DEVELOPMENT ENGINEERING HHuynh 07/21/2025 amorganroth 07/22/2025 CURRENT PLANNING CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 PHOTOMETRIC CALCULATIONS P1.0 32 Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - L A N D S C A P E - I L U M . d w g DEVELOPMENT ENGINEERING HHuynh 07/21/2025 NE SUNSET BLVD 24' PROPOSED MEDICAL OFFICE SHELL 5,200 SF FOOTPRINT 3+00 4+00 5+00 6+00 PI : 5 + 9 5 . 0 7 SSSS W 303.5 LF - LS PV LS MWATER VALVE WATER MANHOLE EXISTING 12" GV AS P H A L T ASPHALT GR A V E L ASPHALT SIDEWALK - >SB SI G N A L B O X SB TV S2 6 ° 0 2 ' 3 3 " E 4 5 . 0 0 ' N63° 57' 27"E 595.07' N63° 57' 27"E 828.07' 0+00 BP : 0 + 0 0 . 0 0 FO U N D I N V E R T E D N A I L I N CO N C R E T E P O S T , I N C A S E D 14+00 14+23 EP : 1 4 + 2 3 . 1 4 FO U N D I N V E R T E D N A I L I N CO N C R E T E P O S T , I N C A S E D CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 GRAPHIC SCALE 0 20 40 1" = 20 FEET 10 N ILLUMINATION PLAN IL1.0 33 VERTICAL DATUM = NORTH AMERICAN VERTICAL DATUM NAVD 88 (CITY OF RENTON) CITY OF RENTON SURVEY CONTROL POINT 2189 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY ELEVATION: 400.60' SITE NO.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH END OF 6' CYCLONE FENCE. ELEVATION: 396.77 BENCHMARK Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - L I G H T I N G . d w g T-433501 LUMINAIRE POLE SCHEDULE LUMINAIRE POLE NO. RENTON POLE NO. *STATION REFERENCE STATION POLE OFFSET LATITUDE **LONGITUDE **MOUNTING HEIGHT ARM LENGTH WATTAGE COMMENTS NE SUNSET BLVD.4+28.61 33.4FT RT 20.0'4.0'44W NE SUNSET BLVD.5+01.56 33.4FT RT 40.0'4.0'44W NE SUNSET BLVD.5+60.61 33.4FT RT 20.0'4.0'44W 1 2 3 1 2 3 *CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE MANAGER ERIC CUTSHALL, 425-430-7423 FOR POLE NUMBERS TO BE INCLUDED ON POLES. ** CONTRACTOR SHALL DETERMINE FINAL COORDINATES FOR RECORD DRAWINGS. INSTALL DOME STYLE LED 44W FIXTURE ON POLE PER COR STD PLAN 117.1, 117.2 AND 117.3. POLE ARMS TO FACE TOWARD SIDEWALK. COORDINATE WITH CITY INSPECTOR FOR CONNECTION TO ELECTRICAL SERVICE. (VERIFY SERVICE HAS CAPACITY) INSTALL LUMINAIRE AND JUNCTION BOX CONCRETE PAD. INSTALL TYPE 1 JUNCTION BOX CONSTRUCTION NOTES 1 1 1 1 2 3 4 2 3 33 4 44 WIRING SCHEDULE KEYNOTE NO.RACEWAY CONDUIT SIZE *CONDUCTOR COMMENTS 2" SCH80 2 - #8 *ALL CONDUIT SHALL BE PVC AND SHALL CONTAIN A GROUND WIRE EQUAL IN SIZE TO THE LARGEST CONDUCTOR (MINIMUM NO. 8) UNLESS OTHERWISE NOTED. 1 1 1 1 1 1 1 1.ALL WORK SHALL BE IN ACCORDANCE WITH RENTON STANDARD SPECIFICATIONS, RENTON STANDARD PLANS, AND THE CONTRACT, UNLESS OTHERWISE NOTED. A COPY OF THESE DOCUMENTS SHALL BE ON SITE DURING CONSTRUCTION. 2.A COPY OF THE APPROVED PLAN SHALL BE ON SITE DURING CONSTRUCTION. 3.ALL PERMITS REQUIRED FOR WORK WITHIN THE PUBLIC RIGHT OF WAY MUST BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4.THE LOCATION OF EXISTING FEATURES AND UTILITIES SHOWN WITHIN THESE PLANS ARE APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCING LIGHTING WORK. NOT ALL EXISTING FEATURES AND UTILITIES MAY BE SHOWN. 5.LUMINAIRE WIRING SHALL BE PER THIS PLAN AND CITY OF RENTON STANDARD PLAN 119. 6.STREET LIGHT POLES SHALL BE NUMBERED PER CITY OF RENTON STANDARD PLAN 121. COORDINATE WITH THE CITY OF RENTON FOR NUMBERING. 7.FUSING AND/OR SPLICING OF LUMINAIRE WIRING SHALL BE PER CITY OF RENTON STANDARD PLAN J013. 8.ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I.E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 9.ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 10.ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 11.LUMINAIRE AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 12.ALL ILLUMINATION SYSTEM ARE SUBJECT TO INSPECTION BY CITY OF RENTON TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE REPRESENTATIVE. 13.CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL (425) 430-7423 FOR STREET LIGHTING INSPECTION PRIOR TO ENERGIZING. 14.THE CONTRACTOR SHALL SUBMIT, FOR REVIEW BY THE ENGINEER, DESIGNS FOR THE LUMINAIRE POLE FOUNDATIONS THAT BEAR THE SEAL AND SIGNATURE OF A VALID LICENSED WASHINGTON STATE PROFESSIONAL ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY STRUCTURAL AND/OR GEOTECHNICAL ANALYSIS THAT MAY BE NEEDED TO DETERMINE THE NECESSARY FOUNDATION DEPTHS FOR THE NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE POLES, IN ACCORDANCE WITH CITY OF RENTON STANDARD PLAN 116.1. A GEOTECHNICAL ENGINEER SHALL BE PRESENT AT THE TIME OF BORING OF THE FOUNDATION TO VERIFY SOIL CONDITIONS. GENERAL NOTES 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 Luminaire 1 and 3 shall be per COR std 117.2 with 44W LED fixture, 4-ft arm, 20-ft clearance, no flower basket and facing sidewalk. Luminaire 2 shall be per COR std 117.1 with dual fixtures: with one at 35-ft clearance facing street, 8-ft arm and 110W fixture; and lower fixture with 20-ft clearance, facing sidewalk, 4-ft arm and 44W fixture. TRANSPORTATION OPERATION cbarnes 07/29/2025 CITY OF RENTON IN COMPLIANCE WITH CITY OF RENTON STANDARDS T A C O M A 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422TEL 253.383.2572FAX www.ahbl.comWEB S E A T T L E S P O K A N E T R I - C I T I E S SUNSET MEDICAL OFFICE BUILDING AHBL JOB #2230621.10 34 Know what's below. before you dig.Call R C2 4 0 0 6 3 2 7 PR 2 4 - 0 0 0 0 5 2 LU A 2 4 - 0 0 0 2 1 8 TE D - 4 0 - 4 3 3 5 ILLUMINATION DETAILS IL1.1 34 Q: \ 2 0 2 3 \ 2 2 3 0 6 2 1 \ 1 0 _ C I V \ C A D \ _ F i n a l D e s i g n \ 2 2 3 0 6 2 1 - S H - L I G H T I N G . d w g T-433502 07/21/2025 DEVELOPMENT ENGINEERING HHuynh 07/21/2025 use of cor std plan J013 - Splice kit required where needed. TRANSPORTATION OPERATION cbarnes 07/29/2025