Loading...
HomeMy WebLinkAboutR-433511LO C') C'7 It I 0 w I — q e� Know what's below. Call before you dig. 4"-6" RECOMMENDED CURB INLET THROAT OPENING CAST -IN PLACE CURB & GUTTER BY OTHERS CURB INLET DETAIL SEE CURB INLET DETAIL THIS SHEET LEFT END VIEW ALTERNATE OUTLET LOCATION M11i 012" RCP MAX. OUTLET INLET CONTOUR RACK WITH PERFORATED FLOOR OPENING TO BIOFILTRATION CHAMBER 18"X36" ACCESS HATCH BYPASS WEIR/OUTLET BAY 6" TOP SLAB - -I— 4'-0" 3'-0" 4X6 BIOPOD SURFACE VAULT WITH INTERNAL BYPASS NOT TO SCALE T @� �i T A C O M A S E A T T L E �46 SPOKANE TRI-CITIES ��of sslGIST 9 Eg�1�� 2215 North 30th Street, Suite 300 Tacoma, WA 98403 ONAL E 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 07/21 /2025 7'-0" 4'-0" -1 PLAN VIEW ELEVATION VIEW ALTERNATE INLET LOCATIONS AVAILABLE CURB INLET WITH 6" NOSING 24"x7" OPENING FOR CURB INLET 36"X36" ACCESS HATCH 2" MULCH 1'-T StormMixTM MEDIA 6" DRAIN ROCK UNDERDRAIN PIPE Bioretention/ Biofiltration NOTES: 1. DESIGN LOADINGS: A. 300 PSF PEDESTRIAN LOADING B. DESIGN SOIL COVER: 0' MAXIMUM C. ASSUMED WATER TABLE: BELOW BASE OF PRECAST (ENGINEER -OF -RECORD TO CONFIRM SITE WATER TABLE ELEVATION) D. LATERAL EARTH PRESSURE: 45 PCF (DRAINED) E. LATERAL LIVE LOAD SURCHARGE: 80 PSF (APPLIED TO 8'-0" BELOW GRADE) F. NO LATERAL SURCHARGE FROM ADJACENT BUILDINGS, WALLS, PIERS, OR FOUNDATIONS. 2. CONCRETE 28-DAY MINIMUM COMPRESSIVE STRENGTH: 5,000 PSI MINIMUM. 3. REINFORCING: REBAR, ASTM A615/A706, GRADE 60 4. CEMENT: ASTM C150 5. REQUIRED ALLOWABLE SOIL BEARING CAPACITY: 2,500 PSF 6. REFERENCE STANDARD: A. ASTM C890 B. ASTM C913 C. ACI318-14 7. THIS STRUCTURE IS DESIGNED TO THE PARAMETERS NOTED HEREIN. ENGINEER -OF -RECORD SHALL VERIFY THAT NOTED PARAMETERS MEET OR EXCEED PROJECT REQUIREMENTS. IF DESIGN PARAMETERS ARE INCORRECT, REVIEWING ENGINEER/AUTHORITY SHALL NOTIFY OLDCASTLE INFRASTRUCTURE UPON REVIEW. 8. INLET AND OUTLET HOLES WILL BE FACTORY CORED/CAST PER PLANS AND CUSTOMER REQUIREMENTS. INLET AND OUTLET LOCATIONS CAN BE MIRRORED. 9. CONTRACTOR RESPONSIBLE TO VERIFY ALL SIZES, LOCATIONS, AND ELEVATIONS OF OPENINGS. 10. CONTRACTOR RESPONSIBLE TO ENSURE ADEQUATE BEARING SURFACE IS PROVIDED (I.E. COMPACTED AND LEVEL PER PROJECT SPECIFICATIONS). 11. SECTION HEIGHTS, SLAB/WALL THICKNESSES, AND KEYWAYS ARE SUBJECT TO CHANGE AS REQUIRED FOR SITE REQUIREMENTS AND/OR DUE TO PRODUCT AVAILABILITY AND PRODUCTION FACILITY CONSTRAINTS. 12. MAXIMUM PICK WEIGHTS": A. TOP: XX,XXX LBS B. BASE: XX,XXX LBS' (' COMBINED WEIGHT OF BASE INCLUDES BYPASS WEIR, DIVIDER WALL, ROCK & MEDIA) 13. INTERNALS SHALL CONSIST OF UNDERDRAIN PIPE, ROCK, STORMMIXTA4 MEDIA, MULCH, AND INLET CONTOUR RACK. R-433511 r\ N CM QD C) O N � U N Ln C) C) I N 00 T N O O I N Q D J