Loading...
HomeMy WebLinkAboutR-433512Co co It I 0 W q e� Know what's below. Call before you dig. f')111 IKIr% r%t-%X/r r) RIM: 398.05 OUTLET STRUCTURE NOTES 1. METAL PARTS: CORROSION RESISTNAT. NON -GALVANIZED PARTS PREFERRED. GALVANIZED PIPE PARTS TO HAVE ASPHALT TREATMENT. 2. FRAME AND LADDER OR STEPS OFFSET SO: 2.1. CLEANOUT GATE IS VISIBLE FROM TOP. 2.2. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. 3. PROVIDE AT LEAST ONE 3" X 0.090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM T VERTICAL SPACING) 4. REFER TO CITY OF RENTON FLOW CONTROL STRUCTURE STANDARD DETAIL FOR ADDITIONAL NOTES 54-INCH CONTROL STRUCTURE SCALE: 1 "=2' �+ T . kr WASfJj, @� T A C O M A S E A T T L E rt S P O K A N E T R I- C I T I E S ��1069�g���� w� 2215 North 30th Street, Suite 300 Tacoma, WA 98403 NAL E 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 07/21 /2025 _E ..RO. V DocuSign Envelope ID: 3B1 B34D3-7EOA-476C-ADB3-4329FFEOC108 ADDITIONAL LADDER RUNGS (IN SETS) TO 2' MIN. CLEARANCE TO ALLOW ACCESS TO TANKS OR VAULTS ANY PORTION OF FLOW RESTRICTOR �`�l� WHEN CATCH IS FILLED WITH WATER TEE INCLUDING ELBOWS / REMOVABLE WATERTIGHT COUPLING OR FLANGE 2" MIN. I /� /I 1 _ �� \ I I II I l J ELBOW RESTRICTOR, SEE DETAIL AND NOTE 10 I 1 ANGLE AS / NECESSARY, � SEE NOTE 7 6" MIN. 6" MAX. 2' MIN, PLATE WELDED TO ELBOW WITH PLAN VIEW ORIFICE AS SPECIFIED, SEE NOTE 3 ELBOW RESTRICTOR DETAIL ELEVATION PER PLANS FRAME & SOLID COVER MARKED "DRAIN" WITH 12" MIN. UNDER LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 PAVEMENT =[-�T.IJ,Ji J•]rom 16" MAX. VERTICAL BAR GRATE FOR SECONDARY INLET 6" MIN. LESIUGN WATER ELBOW RESTRICTOR, FACE SEE DETAIL AND NOTE 10 HANDHOLDS, STEPS, OR LADDER PIPE SUPPORTS, SEE NOTE 6 " (TYP.) 1.5 x D SEE NOTE 9 (TYP.) MIN. MIN. — � I I i OUTLET PIPE, SEE INLET PIPE NOTES 1 & 5 2' o MIN. SHEAR GATE WITH CONTROL ROD FOR INVERT AND CLEANOUT/DRAIN (ROD BENT AS REQUIRED ELEVATION PER PLANS FOR VERTICAL ALIGNMENT WITH COVER) 12" SECTION OF PIPE ATTACHED BY 2 PER STD. PLAN 237.30 GASKETED BAND TO ALLOW REMOVAL MIN. 12" 1 WELDED RESTRICTOR PLATE WITH ORIFICE DIA AS SPECIFIED, SEE NOTE 10 a=i` ri rh ki A 1. USE A MIMIMUM OF A 54" DIAMETER TYPE 2 CATCH BASIN. 2. OUTLET CAPACITY: 100-YEAR DEVELOPED PEAK FLOW. 3. METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 4. FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. 5. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4". 6. PROVIDE AT LEAST ONE 3" X .090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM 3'-0" VERTICAL SPACING). 7. LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN. 8. LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER. 9. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10. IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 237.00 c PUBLIC WORKS FLOW CONTROL STRUCTURE - �I� DEPARTMENT RESTRICTOR TEE CITY OF RENTON FLOW CONTROL STRUCTURE DATE 0 1 8: R-433512 r\ N co CO C) O Nt N A, LJ N C) C) I Nt N LL N C) C) C) N Q D J