STORMTECH HIGHLY RECOMMENDS
FLEXSTORM INSERTS IN ANY UPSTREAM
STRUCTURES WITH OPEN GRATES
ELEVATED BYPASS MANIFOLD
SUMP DEPTH TBD BY
SITE DESIGN ENGINEER NYLOPLAST
(24" [600 mm] MIN RECOMMENDED)
INSTALL FLAMP ON 24" (600 mm) ACCESS PIPE
PART#: SC74024RAMP
SC-800 CHAMBER
24" (600 mm) HDPE ACCESS PIPE REQUIRED
USE END CAP PART #: SC800EPE24BPC
SC-800 ISOLATOR ROW PLUS DETAIL
NTS
STORMTECH ISOLATOR ROW DETAIL
NOT TO SCALE
11 MT1 f-%KIAI I K I C'` n r n T 1/% K l Ml1 M-r
SC-800 END CAP
N" "., ". --
FOUNDATION WOVEN GEOTEXTILE BETWEEN-
FOUNDATION STONE AND CHAMBERS
5' (1.5 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS
6
12.2"
(310 mm)
SC-800 TECHNICAL SPECIFICATION
46.5" (1181 mm)
51.0"
(1295 mm)
NOMINAL CHAMBER SPECIFICATIONS
1m)
NTS
1m)
f-MICCI AC AICVT f'UAr010CE:) UCCC
a BUILD ROW IN THIS DIRECTION
85.4" (2169 mm) INSTALLED LENGTH
90.6" (2301 mm) ACTUAL LENGTH
SIZE (W X H X INSTALLED LENGTH)
51.0" X 33.0" X 85.4"
(1295 mm X 838 mm X 2169 mm)
CHAMBER STORAGE
50.6 CUBIC FEET
(1.43 m3)
MINIMUM INSTALLED STORAGE*
81.0 CUBIC FEET
(2.29 m3)
WEIGHT
81.81bs.
(37.1 kg)
UNDERDRAIN DETAIL
NTS NOMINAL END CAP SPECIFICATIONS
STORMTECH STORMTECH SIZE (W X H X INSTALLED LENGTH)
46.5" X 32.6" X 10.5"
(1181 mm X 828 mm X 267 mm)
CHAMBERS STORMTECH CHAMBER END CAP STORAGE
3.4 CUBIC FEET
(0.09 m3)
END CAP MINIMUM INSTALLED STORAGE**
15.4 CUBIC FEET
(0.43 m3)
WEIGHT
OUTLET MANIFOLD
15.71bs.
(7.1 kg)
FOUNDATION STONE
BENEATH CHAMBERS
ADS GEOSYNTHETICS 601
NON -WOVEN GEOTEXTIL
STORMTECH
END CAP
FOUNDATION STONE
BENEATH CHAMBERS
ADS GEOSYNTHETICS 601T
NON -WOVEN GEOTEXTILE
I -1-1 x -- L I 1 I I L "I L.,1. 11- I "I x VI I" JESIGN ENGINEER
4" (100 mm) TYP FOR SC-310 & SC-160LP SYSTEMS
6" (150 mm) TYP FOR SC-800, DC-780, MC-3500, MC-4500 & MC-7200 SYSTEMS
CHAMBER UNDERDRAIN
NOT TO SCALE
Know what's below.
Call before you dig.
�+ T. xrj
�VO� pg WASk j*N <
�
ado,\ SEC T72
�`sSIONAL
C1=rT1r)K1 R_R
T A C O M A S E A T T L E
S P O K A N E T R I- C I T I E S
2215 North 30th Street, Suite 300 Tacoma, WA 98403
253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB
L WALL
FORATED
E
ERDRAIN
* ASSUMES 6" (152 mm) STONE ABOVE, BELOW, AND BETWEEN CHAMBERS
**ASSUMES 6" (152 mm) STONE ABOVE AND BELOW END CAPS, 6" (152 mm) BETWEEN ROWS, 12" (305 mm) BEYOND END CAPS
PRE -CORED HOLES AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "BPC"
PRE -CORED HOLES AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "TPC"
PART #
STUB
B
C
SC800EPE06TPC
6" (150 mm)
21.4" (544 mm)
---
SC800EPE06BPC
---
0.9" (23 mm)
SC800EPE08TPC
8° (200 mm)
19.2" (488 mm)
---
SC800EPE08BPC
---
1.0" (25 mm)
SC800EPE10TPC
10" (250 mm)
17.0" (432 mm)
---
SC800EPE10BPC
---
1.2" (30 mm)
SC800EPE12TPC
12" (300 mm)
14.4" (366 mm)
---
SC800EPE12BPC
---
1.6" (41 mm)
SC800EPE15TPC
15" (375 mm)
11.3" (287 mm)
---
SC800EPE15BPC
---
1.7" (43 mm)
SC800EPE18TPC
18" (450 mm)
8.0" (203 mm)
---
SC800EPE18BPC
---
2.0" (51 mm)
SC800EPE24BPC
24" (600 mm)
---
2.3" (58 mm)
SC800EPE
NONE
SOLID END CAP
NOTE: ALL DIMENSIONS ARE NOMINAL
CHAMBER SPECIFICATIONS
NOT TO SCALE
C
START
END
R-433514
r\
t'J
CO
O
O
N
u
�,
N
O
O
O
O
N
KOC
O
O
O
N
Q
D
J
07/21 /2025