Loading...
HomeMy WebLinkAboutR-433514Co co It i 6 0 W I - STORMTECH HIGHLY RECOMMENDS FLEXSTORM INSERTS IN ANY UPSTREAM STRUCTURES WITH OPEN GRATES ELEVATED BYPASS MANIFOLD SUMP DEPTH TBD BY SITE DESIGN ENGINEER NYLOPLAST (24" [600 mm] MIN RECOMMENDED) INSTALL FLAMP ON 24" (600 mm) ACCESS PIPE PART#: SC74024RAMP SC-800 CHAMBER 24" (600 mm) HDPE ACCESS PIPE REQUIRED USE END CAP PART #: SC800EPE24BPC SC-800 ISOLATOR ROW PLUS DETAIL NTS STORMTECH ISOLATOR ROW DETAIL NOT TO SCALE 11 MT1 f-%KIAI I K I C'` n r n T 1/% K l Ml1 M-r SC-800 END CAP N" "., ". -- FOUNDATION WOVEN GEOTEXTILE BETWEEN- FOUNDATION STONE AND CHAMBERS 5' (1.5 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS 6 12.2" (310 mm) SC-800 TECHNICAL SPECIFICATION 46.5" (1181 mm) 51.0" (1295 mm) NOMINAL CHAMBER SPECIFICATIONS 1m) NTS 1m) f-MICCI AC AICVT f'UAr010CE:) UCCC a BUILD ROW IN THIS DIRECTION 85.4" (2169 mm) INSTALLED LENGTH 90.6" (2301 mm) ACTUAL LENGTH SIZE (W X H X INSTALLED LENGTH) 51.0" X 33.0" X 85.4" (1295 mm X 838 mm X 2169 mm) CHAMBER STORAGE 50.6 CUBIC FEET (1.43 m3) MINIMUM INSTALLED STORAGE* 81.0 CUBIC FEET (2.29 m3) WEIGHT 81.81bs. (37.1 kg) UNDERDRAIN DETAIL NTS NOMINAL END CAP SPECIFICATIONS STORMTECH STORMTECH SIZE (W X H X INSTALLED LENGTH) 46.5" X 32.6" X 10.5" (1181 mm X 828 mm X 267 mm) CHAMBERS STORMTECH CHAMBER END CAP STORAGE 3.4 CUBIC FEET (0.09 m3) END CAP MINIMUM INSTALLED STORAGE** 15.4 CUBIC FEET (0.43 m3) WEIGHT OUTLET MANIFOLD 15.71bs. (7.1 kg) FOUNDATION STONE BENEATH CHAMBERS ADS GEOSYNTHETICS 601 NON -WOVEN GEOTEXTIL STORMTECH END CAP FOUNDATION STONE BENEATH CHAMBERS ADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE I -1-1 x -- ­L I 1 I I L "I L.,1. 11- I "I x VI I" JESIGN ENGINEER 4" (100 mm) TYP FOR SC-310 & SC-160LP SYSTEMS 6" (150 mm) TYP FOR SC-800, DC-780, MC-3500, MC-4500 & MC-7200 SYSTEMS CHAMBER UNDERDRAIN NOT TO SCALE Know what's below. Call before you dig. �+ T. xrj �VO� pg WASk j*N < � ado,\ SEC T72 �`sSIONAL C1=rT1r)K1 R_R T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB L WALL FORATED E ERDRAIN * ASSUMES 6" (152 mm) STONE ABOVE, BELOW, AND BETWEEN CHAMBERS **ASSUMES 6" (152 mm) STONE ABOVE AND BELOW END CAPS, 6" (152 mm) BETWEEN ROWS, 12" (305 mm) BEYOND END CAPS PRE -CORED HOLES AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "BPC" PRE -CORED HOLES AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "TPC" PART # STUB B C SC800EPE06TPC 6" (150 mm) 21.4" (544 mm) --- SC800EPE06BPC --- 0.9" (23 mm) SC800EPE08TPC 8° (200 mm) 19.2" (488 mm) --- SC800EPE08BPC --- 1.0" (25 mm) SC800EPE10TPC 10" (250 mm) 17.0" (432 mm) --- SC800EPE10BPC --- 1.2" (30 mm) SC800EPE12TPC 12" (300 mm) 14.4" (366 mm) --- SC800EPE12BPC --- 1.6" (41 mm) SC800EPE15TPC 15" (375 mm) 11.3" (287 mm) --- SC800EPE15BPC --- 1.7" (43 mm) SC800EPE18TPC 18" (450 mm) 8.0" (203 mm) --- SC800EPE18BPC --- 2.0" (51 mm) SC800EPE24BPC 24" (600 mm) --- 2.3" (58 mm) SC800EPE NONE SOLID END CAP NOTE: ALL DIMENSIONS ARE NOMINAL CHAMBER SPECIFICATIONS NOT TO SCALE C START END R-433514 r\ t'J CO O O N u �, N O O O O N KOC O O O N Q D J 07/21 /2025