HomeMy WebLinkAboutW-433501DROP -IN METER BY CITY FORCES. DROP -IN METER PERMIT REQUIRED EXISTING DOMESTIC - SERVICE LINE TO BE CUT AND CAPPED STA:1 +03.46, 0.00' AT MAIN BY CITY FORCES. CUT AND CAP 1-12"x10" TEE (MJxFL) PERMIT REQUIRED 1-10" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK WET TAP WILL BE IN ACCORDANCE WITH COR STD PLAN 300 6 1 ' SEE STANDARD PLAN 300.5 ON SHEET C5.1 .% / R C5.4 FOR CONNECTION DETAIL. 1�23. EXISTING FIRE HYDRANT \ STA:1 +82.04, 6.50' LT GJ / �( 1" IRRIGATION SERVICE CONNECTION /� P( �NC,12 \ PER COR STD PLAN 320.1 DROP -IN METER BY CITY FORCES. DROP -IN METER PERMIT / / ANITARY SEWER REQUIRED / MANHOLE I M 400.4 12" CONC NE IE 8" PVC 8. I /12" CO W 388 / B® °a / / S :1 +94.9 .16 LT 2 1-FIRE DEP MENT NNECTION FOUND INVERTED NAIL IN ST • 3.96, 0.00' / d ONCRETE POST, INCASED �E 1- 2.50 BEND (MJ S el ° i 1-CONC. THRUST B STA:2+10.34, 6.50' LT 1" WATER SERVICE CONNECTION 0 (BY CITY F(1R(F PER COR STD PLAN 323y�F T + 34, 0.00' 1-10"x "TEE (MJxFL) ° / FOUND INVERTED NAIL IN CONCRETE POST, INCASED / SANITARY SEWER MANHOLE RIM 400.93 8" CONC N 391.53 IE 1" DCVA FOR 12" CONC NE 390.88 IE IRRIGATION �-' / O cP, 6" CONC S 391.82 IE 12" CONC SW 390.90 IE S � JANIT SEWER MANHOLE RI 0.71 / p " CONC NE 388.8_1 FR 12" QE)NC 5W388.61 I GRAVEL- / i 6.50' ROW DEDICATION 6 �� I PROPOSED COMMERCIAL BUILDING i / PRPOSED MEDICAL /'OFFICE SHELL / 6,200 SF FOOTPRINT • FF: 399.50 1" WATER SER\/ACE AND RPBA BACKFLOW I a2 DEVICE SHAD BE PROVIDED INSIDE THE z ° BUILDING PAR COR STD DETAIL 350.2 LS / VA FIR BACKFLOW ASSEMBLY SHALL BE INSTALLED INSIDE THE BUILDING PER COR STD 0TA:2+13.34, 6.49 LT 1-PIV VALVE PER COR STD DTL 360.5 1-6 GATE VALVE (FLxMJ) :2/,T&34, 7.50' LT 1-CONC. THRUST BLOCK ER\FIRE HYDRANT ASSEM MANHOLE SANITARY SEWER FH ASSEMBLY PER COR ° ,4'X4' CON PAD PER RIM 398.25 STD PLAN 310.1, 310.2, 310.3 COR STD DTL 310.2 12" CONC NE 386.00 IE STA:2+21.28, 0.00' \ / \ 12" CONC SW 385.95 IE 1-10" POLYPIG STATION i PER COR STD PLAN 300.7 DETAIL 360.5. FIRE SERVICE LINES TO BE 4" DI CL 52. REFER TO FIRE PROTECTION NOTE ON SHEET C5.7 LO co M U) 2 SSCO #2 RIM:399.33 / IE: 393.80 8" (SW) LO IN / IE: 393.80 8" (SE) 1 I 36 LF 8" PVC @ 2.00% •� � II SSCO #1 RIM: 398.26 IE: 394.51 8" (NW) INSTALL SEWER SERVICE` 1-1 IE: 390.39 8" (E) CO # 5 LF 8" 8% RIM:399.41 GIA ENTERPRISES 6 LF 8" PVC @ 4.36% IE: 392.42 8" (NW) 0323059097 9j 35 LF 8" SSCO #6 IE: 392.42 8" (NE) / C0 RIM: 398.23 IN PVC @ 3.5 ° 8' /0 398 A IE: 390.65 8" (W) 4"FIR .:: � \ Q IE: 390.65 8" (E) � R91 I 9 3 � < 20' SEWER EASEMEN 16"FI "� 1.9 ) E: 8" SE) < WORKMAN ARLENE M. \ i 0323059055 .0"FI 16"FIRS Ix W W W I W _ / 3g6 I I 9 , I 30IR 24" FIRM / / 40 .00' STREAM �I BUFFS / �' V`tF 8 14"FIR l � \ . . . =� SANITARY SEWER MANHOLE - RIM 396.32 8" PVC S 393.35 IE 8" PVC SE 393.38 IE 8" PVC N 393.27 IE 164.55 N890 37; 58 W 16"FI 0" Fir /BECK HOLDINGS LLC 30 -393' % j / i ii 0323059044 F /� I f /-392- O pF WASgj���O�l 0 Q Q�� TACOMA • SEATTLE rl ;P 46972 wSPOKANE TRI-CITIES �,srsTER�O 2215 North 30th Street, Suite 300 Tacoma, WA 98403 Know what's below. SIGNAL E� 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Call before you diq. 07/21/2025 ° 2- ROCKERY SURVEYED: DESIGNED: QF DRAWN: QF 1 PLANS REVISED PER COR 1ST REVIEW COMMENTS QF 2/21/25 CHECKED: SK NO. REVISION BY DATE APPR APPROVED: SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY STREAM BUFFER EDGE OF STREAM STREAM BUFFER NCHMARK DA*C71TY CAL DATUM = NORTH AMERICAN VERTICAL M NAVD 88 (CITY OF RENTON) F RENTON SURVEY CONTROL POINT 2189 405 EXISTING ROAD CENTERLINE Ew STA: 1 +03.46 1-12"x10" TEE (MJxFL) 1-10" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK WET TAP WILL BE IN ACCORDANCE WITH COR STD PLAN 300.6. SEE STANDARD PLAN 300.5 ON SHEET C5.4 FOR CONNECTION DETAIL. 395 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY ELEVATION: 400.60' SITE NO.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH END OF 6' CYCLONE FENCE. ELEVATION: 396.77 PROPOSED ROW I BOUNDARY EXIST G ROW BOUNDARY PROPOSED GRADE AT SEC TION LINE \ EXISTING GRADE AT J SECTION LINE STA: 1 +55.75 EXISTING 12" STORM MAIN W.- -I IE:395.82 c�s2 T 1I 1 1 1.50' 1.50' i i 1 N GRAPHIC SCALE N 0 10 20 40 CY) O 1" = 20 FEET O N U LO 405 O O IN AREAS OF FILL, NEW ROADWAY SUBGRADE SHALL BE FILLED AND COMPACTED BEFORE EXCAVATION (V FOR INSTALLATION OF NEW WATER MAIN (TYP) 400 00 O T N - O O C) _ N STA: 1 +90.03 Q PROPOSED 6" ST RM _ J 395 STA: 2+21.28 1-10" POLYPIG STATION PER COR STD PLAN 300.7 1-22. ° BEND (MJ) / 1-CONC. TH UST BLOCK 22 LF 8" J STA: 2+16.34 5 LF 8" TA: 1+47.62 1-10' 6" TEE (MJxFL) 390 EXISTING 12" EWER MAIN 1- AT VALVE FLxM D.I. CL52 390 T.O.P: 389.29 1-CONC. HRUST BLOCK \ I FH ASS MBLY PER COR EX STING GRADE PROPOSED GRADE 387 AT SECTION LINE AT SECTION LINE 7 r7 �, 0 o cfl 00 o rno ao7 06Iq r10 o 0)0 WWCD 00 00 CDM M �`� M W W LL W LL WILL W LL 1+00 1+50 2+00 2+31.28 10 SITE SECTION 4 SCALE: H:1 "=20', V:1 "=2' W-433501 S-433501 R-433518 IN COMPLIANCE WITH CITY OF RENTON STANDARDS R DEVELOPMENT ENGINEERING ` • LHuynh 07/21/2025 '� WATER UTILITY WASTEWATER UTILITY U;%RW ABDOUL GAFOUR 07/25/2025 `� jstowell 07/28/2025 VERTICAL: NAVD 1988• SUNSET MEDICAL D I CAL OFFICE BUILDING DATE: FOR HORIZONTAL: NAD 1983/183/1991 CITY OF CONSTRUCTION FIELDBOOK: RENTON PAGE: ;R AHBL JOB #2230621.10 DATUM • DRAWING NO: Planning/Building/Public Works Dept. UTILITY PLAN C5.1 SHEET: 18 OF: 34