Loading...
HomeMy WebLinkAboutW-433503C'7 C'7 N Know what's below. Call before you dig. NOTES: 1. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF SAFETY YELLOW DTM ACRYLIC GLOSS OR ENAMEL PAINT. 2. PUMPER NOZZLE TO FACE ROADWAY OR AS DIRECTED BY RRFA. 3. A MINIMUM 3' RADIUS UNOBSTRUCTED WORKING AREA SHALL BE PROVIDED AROUND THE OUTSIDE OF THE HYDRANT. KA ATCDI AI f O HYDRANT O TEE OC VALVE OD VALVE BOX OE PIPE OF JOINT RESTRAINT OG GRAVEL OH CONCRETE BLOCK OI BLOCKING JO SHEAR BLOCK O PAVEMENT MARKER COMPRESSION TYPE HYDRANT (SEE APPROVED MATERIALS LIST) WITH 6" MJ INLET WITH LUGS, 5 %4" MVO, 1 %4" PENTAGON OPERATING NUT, TWO (2) 2 %" NST HOSE NOZZLES, AND 4.875" SST PUMPER NOZZLE EQUIPPED WITH 5" STORZ ADAPTER AND 1/8" STAINLESS STEEL CABLE, WITH EXTENSION IF NECESSARY. MAIN LINE TEE WITH 6" FLANGE SIDE OUTLET 6" GATE VALVE (FLxMJ) VALVE BOX AND LID PER STD PLAN 330.7 AND CLASS 52 DI, LENGTH TO FIT MECHANICAL JOINT RESTRAINT WITH CONCRETE BLOCKING (2) 3/4" CORTEN STEEL TIE RODS 1 %4" WASHED DRAIN ROCK, MINIMUM 1' ABOVE BOOT FLANGE WITH 8-MIL POLYETHYLENE SHEETING AROUND TOP AND SIDES OF GRAVEL MINIMUM 16"x8"x4" CONCRETE BLOCKS UNDER FIRE HYDRANT AND GATE VALVE CONCRETE BLOCKING PER STD PLAN 330.1 4'x4'x6" CONCRETE SHEAR BLOCK AROUND FIRE HYDRANT, SEE STANDARD DETAIL 310.2 BLUE REFLECTIVE PAVEMENT MARKER PER STD PLAN 310.3 STD. PLAN - 310.1 PUBLIC WORKS APPROVED: CAIR) DEPARTMENT FIRE HYDRANT ASSEMBLY J 6/28/2023 Martin Pastuchavur DATE Public Works Administrator FIRE HYDRANT ASSEMBLY NOT TO SCALE T A C O M A S E A T T L E 16rt w�69S P O K A N E T R I- C I T I E S ��102215 North 30th Street, Suite 300 Tacoma, WA 98403 NAL253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 07/21 /2025 FIRE HYDRANT PAVEMENT MARKER NOT TO SCALE FINISHED GRADE 9" TO 12" d d a \ 24" TO 30" A /jam 221v MAIN LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN SERVICE LINE TO METER MATERIALS O CORPORATION STOP O TUBING OC METER SETTER OD WATER METER OE METER BOX OF COUPLER AND PLUG OG GRAVEL W Z J w Z - IN UNIMPROVED ROW, J w INSTALL METER BOX Cr CITY PRIVATE p AT PROPERTY LINE WITH p r a 1" COPPER TAILPIECE a PIPING PIPING SIDEWALK I �12"� 21" TO 30" G g 1" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET, FORD FB1000-4-Q-NL OR A.Y. MCDONALD 74701BQ 1" TYPE "K" SOFT COPPER TUBING 1" SETTER, QUICK JOINT INLET AND OUTLET, PADLOCK WINGS ON INLET ANGLE BALL VALVE, SINGLE CHECK VALVE ON OUTLET, FORD VBH74-15W-44-44-Q-NL, A.Y. MCDONALD 721-415WCQQ 44, OR MUELLER B-24701-6AN, INSTALL CENTERED AND SQUARED IN METER BOX, PROVIDE ADAPTERS FOR 5/8"x3/4" METERS AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY METER BOX, ARMORCAST A6001946PCX18, WITH METER BOX LID, ARMORCAST A6001969RC1-H7, TO READ "RENTON WATER" COUPLER (PACK JOINT x PACK JOINT), FORD C4#-4#-Q-NL, WITH 1" GALVANIZED PLUG IF SERVICE LINE TO PROPERTY IS TO BE INSTALLED IN THE FUTURE 114" WASHED GRAVEL PUBLIC WORKS DEPARTMENT 1" WATER SERVICE 1 INCH WATER SERVICE NOT TO SCALE Pastucha STD. PLAN - 320.1 UHIt W-433503 N C'D (C) O O Nt N A, u KOE N O C) C) N Q D J