Loading...
HomeMy WebLinkAboutR-4335205 1/2" 1" R FINISH GROUND GRADE PAVEMENT - N '' =III_,, III ;III ;III Q. d NOTE a a IT CONSTRUCTION SHALL CONFORM TO WSDOT SPEC. 8-04.3 a a a 7 3/4" VERTICAL CURB NOT TO SCALE 50 CM (19.7") 16.7 CM (6.6") 25 CM (9.8") ENLARGEMENT SPECIFICATIONS UNIT SIZE - 50 CM X 50 CM X 2.5 CM OR 1 M X 1 M X 2.5 CM (20" X 20" X 1 " OR 40" X 40" X I") AVAILABLE IN 9 STANDARD ROLL SIZES JNIT WEIGHT - 510 GRAMS (18 OZ.) OR 2.0 KG (4.5 POUNDS) ;TRENGTH - 1121 KG/C;M (15,940 PSI) �OLOR - BLACK RESIN - 100% RECYCLED HDPE PLAN GRASSPAVE2 SQUARES ADJACENT GRASSPAVE2 UNITS SEE ENLARGEMENT BELOW HYDROGROW MIX BELOW RING SUPPLIED FREE BY MANUFACTURER HMA CLASS 1/2" PER WSDOT 9-03.8(1) 3" 6'0 0 0 -CRUSHED SURFACING BASE COURSE PER WSDOT 9.03-9(3) 12" COMPACTED NOTES: SUBGRADE TO 95% 1. ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. 2. THE CONTRACTOR SHALL EXPOSE EXISTING SUBGRADE, PROOF ROLL AND COMPACT TO 95%. IF YIELDING CONDITIONS ARE ENCOUNTERED, YIELDING MATERIALS SHALL BE REPLACED WITH IMPORTED STRUCTURAL FILL MATERIAL. THE DEPTH OF MATERIAL REPLACEMENT SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER. PAVEMENT SECTION NOT TO SCALE 10" 6" BOTTOM OF CEMENT CONCRETE CUT/SAWED JOINT o 2.5" 5" L. 2.5" CURB, WSDOT SPEC. 15' INTERVAL 8-04 ��°° III=� III =1-- O° O� 0000° I' O � O0 k O�° O°O O o° � °° O ° SEE LANDSCAPE PLAN o �° �0° o FOR FILL BEHIND CURBS ° EXTRUDED CURB :5: NOT TO SCALE RINGS FILLED WITH CONCRETE SAND (CLEAN, SHARP SAND) -COMPACTED SANDY GRAVEL ROAD BASE s" 95% MODIFIED PROCTOR DENSITY -SEE FULL TECHNICAL SPECIFICATIONS FOR COMPOSITION COMPACTED SUBGRADE, SECTION TOP F GRASS ROOT MASS 6 MM (1 4") ABOVE TOP OF RING GRASSPAVE2 ATTACH WITH SNAP -FIT FASTENERS ;INGS FILLED WITH CONCRETE SAND (CLEAN, SHARP SAND) OMPACTED SANDY GRAVEL BASE COURSE -SEE FULL TECHNICAL SPECIFICATIONS FOR COMPOSITION NOTE: GRASS MIX SHALL BE DEEP ROOTING AND HARDY SPECIES FOR REGION. PROVIDE RYE OR FESCUE LAWN MIX. TYPICAL GRASSPAVE2 DETAIL CHOOSE THIS PRODUCT FOR REINFORCING GRASS WEARING SURFACES NOT TO SCALE 16265 E. 33RD DR., SUITE 20 AURORA, COLORADO 80011 800-233-1510 OR 303-233-8383 FAX: 800-233-1522 OR 303-233-8282 www.invisiblestructures.com GRASSPAVE Invisible Structures, Inc. rev. 1/18 GPDET18.DWG NOT TO SCALE 0 a� Know what's below. Call before you dig. T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S ���.5kEClSTER�9 �� �SSIONAL E2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 07/21 /2025 CC 12" NOTES: 1. ALTERNATIVE - SIGN MAY BE SECURELY MOUNTED TO BUILDING WALL. ADA PARKING SIGN NOT TO SCALE 1/4" EDGED GROOVE 0.02 FT/FT 1.4 a a a a a a a a . a 4" CEMENT CONCRETE SIDEWALK 2" CRUSHED SURFACING TOP COURSE PER PLAN q RAMP DETECTABLE WARNING PATTERN AREA COMPACTED SUBGRADE B SHALL BE YELLOW, IN COMPLIANCE WITH WSDOT STANDARD SPEC. 8-14.3(3) O O 0 NOTES: 1. CEMENT CONCRETE SHALL BE CLASS B. 2. COMPACTION FOR CONCRETE WALKS TO BE 95% MAXIMUM DENSITY. 3. EXPANSION JOINTS CONSISTING OF 3/8" BY 4" PREMOLDED JOINT MATERIAL SHALL BE PLACED AT 15 FOOT INTERVALS, OR AS DIRECTED BY THE ARCHITECTURAL PLANS. 1/4" EDGE GROOVE SHALL BE PROVIDED AT JOINT EDGES. 4. SEE ARCHITECTURAL PLANS FOR JOINT PATTERNS. ONSITE CONCRETE SIDEWALK NOT TO SCALE PAVEMENT 6" FINISH GRADE AT SIDEWALKS ' a a.. a a , 4 a. iv NOTE CONSTRUCTION SHALL CONFORM TO WSDOT a SPECIFICATION 8-04.3. FLUSH CURB NOT TO SCALE L #3 BARS (2) ELEVATION 13/16" DIA. HOLES r%0 A \. 2" CLR (TYP) 5" 2 1/2" � 2 1/2" 6„ #3 BARS (2) 101, NOTES: NON -SHRINK 1. THE NON -SHRINK GROUT USED TO GROUT ATTACH THE PRECAST CURB SHALL CONSIST OF 3:1 SAND AND CEMENT. GROUT TO A DEPTH OF 1" FROM THE TOP OF THE BUMPER. #6 BAR (2) 18" MIN 2. LOCATIONS FOR WEEPHOLES, AND V-SLOTS SHALL BE IDENTIFIED ON ( THE DELIVERY ORDER DRAWINGS. Id 3. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 ATTACHMENT DETAIL PSI AT 28 DAYS. WHEEL STOP NOT TO SCALE CD M MIN MAX A 1 5/8" 2 3/8" B 5/8" 1 1/2" C 7/1 6" 3/4" D 7/8" DETECTABLE WARNING STRIP NOT TO SCALE o 0 0 0 0 0 0 0 0 0 0 o PERMEABLE CONCRETE SECTION 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 U 8" D O O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 AGGREGATE STORAGE RESERVOIR COURSE 12" INFILTRATING FILL VARIES r FIRM AND UNYIELDING /// ///\//\//\//\//\ SUBGRADE PERVIOUS CONCRETE NOTES: 1. A UNIQUE IDENTIFICATION NUMBER FOR THE MIX DESIGN THAT IS APPROVED FOR THE JOB MIX FORMULA (JMF). 2. PORTLAND CEMENT SHALL BE TYPE I, TYPE II, TYPE HI, TYPE IP, OR TYPE IS. 3. CEMENTITIOUS CONTENT: 480 POUNDS PER CUBIC YARD. 4. MIX TO INCORPORATE A HYDRATION STABILIZING ADMIXTURE 5. SYNTHETIC MICROFIBERS MAY BE UTILIZED AT THE MANUFACTURER'S RECOMMENDED DOSAGE RATE. 6. WATER/ CEMENT RATIO SHALL NOT EXCEED 0.35. 7. NO MORE THAN 25 PERCENT OF PORTLAND CEMENT IN THE MIX, BY WEIGHT, MAY BE REPLACED BY FLY ASH, GROUND GRANULATED BLAST FURNACE SLAG, OR A COMBINATION OF BOTH. 8. COARSE AGGREGATE SHALL CONFORM TO SECTION 9-03.1 (4), AASHTO GRADING NO. 8. NOTES: 1. ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. 2. THE CONTRACTOR SHALL EXPOSE EXISTING SUB -GRADE, PROOF ROLL AND COMPACT TO 90-92%. IF YIELDING CONDITIONS ARE ENCOUNTERED, YIELDING MATERIALS SHALL BE REPLACED WITH IMPORTED STRUCTURAL FILL MATERIAL. THE DEPTH OF MATERIAL REPLACEMENT SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER. 3. INFILTRATING FILL BENEATH PERMEABLE CONCRETE SECTION TO PROVIDE INFILTRATION RATES MEETING OR EXCEEDING THE EXISTING UNDERLYING SOILS. FILL MATERIAL TO BE APPROVED BY GROTECHNICAL ENGINEER. INFILTRATION TESTING NOTE PRIOR TO BACKFILL OF INFILTRATING FILL OR PERMEABLE SURFACES, CONTRACTOR SHALL COORDINATE AND RECEIVE WRITTEN GEOTECHNICAL ENGINEER APPROVAL TO BACKFILL MATERIALS. GEOTECHNICAL ENGINEER TO PROVIDE CONFIRMATION OF ACCEPTABLE SUB -GRADE FOR INFILTRATION AND PROVIDE INFILTRATION TESTING AS NEEDED. INFILTRATION VERIFICATION REPORT SHALL BE PROVIDED TO ENGINEER AND CITY INSPECTOR. TESTING SHALL BE IN ACCORDANCE WITH REFERENCE 6-A OF THE 2021 KING COUNTY SURFACE WATER DESIGN MANUAL. FINAL VERIFICATION OF PERFORMANCE TO BE CONDUCTED BY GEOTECHNICAL ENGINEER. THE CITY MUST BE NOTIFIED OF THE SCHEDULED INFILTRATION TESTING AT LEAST 2 WORKING DAYS IN ADVANCE OF THE TEST. PERMEABLE CONCRETE SECTION NOT TO SCALE R-433520 N (fl O Nt N , U N LO O O It N Ir N O O O N Q J