Loading...
HomeMy WebLinkAboutzR-4335setRENTON CONTROL MONUMENTS UTILITIES/SERVICES GRAPHIC SCALE L FOUND INVERTED NAIL IN CITY OF RENTON CONTROL POINT 2097. CONTROL POINT 2097 WAS FOUND TO WATER: CITY OF RENTON 0 10 20 40 CONCRETE POST, INCASED HAVE A LAMBERT GRIDE NORTH ZONE COORDINATE OF 191108.643 FT. / SEWER: CITY OF RENTON a �iO 1316760.378 FT. POWER: PUGET SOUND ENERGY GAS: PUGET SOUND ENERGY Oh CITY OF RENTON CONTROL POINT 1845. CONTROL POINT 1845 WAS FOUND TO TELEPHONE: QWEST COMMUNICATIONS 1" = 20 FEET / c> OWNER HAVE A LAMBERT GRID NORTH ZONE COORDINATE OF 186170.657 FT. / SCHOOLS: SCHOOL DISTRICT NO. 403 N� / 1316637.843 FT. FIRE: RENTON FIRE / o ADF PROPERTIES, LLC 15007 WOODINVILLE-REDMOND `` JO emu'. ROAD SUITE A BASIS OF BEARING �v WOODINVILLE, WA98072 \` G •0 CONTACT: MR. DALE FONK TRUE NORTH. BASED UPON GLOBAL POSITIONING SYSTEM (GPS) LAMBERT GRID WASHINGTON STATE NORTH ZONE COORDINATES. A CONVERGENCE / / ' Sv� i �' / / / CIVIL ENGINEER ARCHITECT ANGLE OF 00 58 31.09" COUNTERCLOCKWISE WAS APPLIED AT A BRASS PIN IN CONCRETE POST, INCASES, AT THE INTERSECTION OF 148TH AVENUE SE AND AHBL ENGINEERS, PLANNERS, & JON GRAVES ARCHITECTS & SE 112TH STREET. THE MONUMENT IS THE SOUTHEAST SECTION CORNER OF �B> SURVEYORS PLANNERS, PLLC SECTION 3, TOWNSHIP 23 NORTH, RANGE 5 EAST OF THE WILLAMETTE /p.`�Q 2215 NORTH 30TH STREET, SUITE 300 3110 RUSTON WAY, SUITE B MERIDIAN. THE NORTH AMERICAN DATUM OF 1983/1991 (NAD 83/91) GRID L c TACOMA, WA 98403 TACOMA, WA 98403 COORDINATES WERE FOUND TO BE 186170.695 / 1316637.784 AT THAT POINT. i ° ° PH. (253) 383-2422 PH. (253) 272-4214 THE INVERSE OF BOTH THE SEA LEVEL CORRECTION FACTOR OF 0.999981199 FAX (253) 383-2572 FAX (253) 272-4218 AND THE GRID SCALE FACTOR OF 0.999999475 WAS APPLIED TO THE GRID i`z2,�, `c��l / �' , i� �. CONTACT: MATT WEBER, PE CONTACT: TYLER GRAFF COORDINATES FOR SHOWN GROUND DISTANCES. GRAVEL SURVEYOR WETLAND CONSULTANT LEGAL DESCRIPTION CENTRE POINT CONSULTANTS, INC., PS WETLAND RESOURCES LOT 2 OF CITY OF RENTON SHORT PLAT NO. 345-79, i NN GJ \ \ N / / i S i / / 206 RAILROAD AVENUE NORTH 9505 19TH AVE. SE, SUITE 106 RECORDED UNDER KING COUNTY RECORDING NO. 0 i �P�� NG�2 \\ KENT, WA 98032 EVERETT, WA 98208 7908179008, BEIGN A PORTION OF THE iJp, �s�� / i �/ i i ate.. PH. (253) 813-1901 PH. (425) 337-3174 SOUTHWEST QUARTER OF SECTION 3, TOWNSHIP �(E� �� \ �� i c' i �., q, �` / FAX (253) 813-1908 CONTACT: SCOTT BRAINARD 23 NORTH, RANGE 5 EAST, W.M., IN KING COUNTY, `NP' / \ 5g5° o �5�1 ° / /< CONTACT: STEPHEN WOODS, PLS WASHINGTON. i � \ 6951 \ S ✓ ��°� / / SITE ADDRESS ��' / / psPNP�\ �S\' ' a ' '/Cn 4401 NE SUNSET BOULEVARD RENTON, WA 98059 > / B® \ ° / \ \ / DATUM BENCHMARK VERTICAL / DATUM NAVD 88 CIT NORTH AN VERTICAL OF RENTON) FOUND INVERTED NAIL IN / CONCRETE POST, INCASED l PARCEL NUMBER 0323059093 TRENCH NOTE IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3) IT SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKER SAFETY AND AHBL ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTE SHALL MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND HEALT ACT, CHAPTER 49.17 RCW. UTILITY NOTE M 6.50 ROW DEDICATION I PZ CITY OF RENTON SURVEY CONTROL POINT 2189 BASE: CITY OF RENTON CONTROL POINT #1845 PROPOSED MEDICAL ° FOUND MONUMENT INCASED AT STREET OFFICE SHELL INTERSECTION OF 148TH AVENUE SOUTHEAST 5,200 SF FOOTPRINT AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET / SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE Q OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT = CENTER OF DRIVEWAY B I \ d O I LS Q ELEVATION:400.60' \ cL \ a I 4. SITE NO.2 R 4 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH S I m� / END OF 6' CYCLONE FENCE. 4.G ° ELEVATION: 396.77 HILO a �, 4 ` ILID o ° o THE LOCATIONS OF EXISTING UNDERGROUND ool UTILITIES ARE APPROXIMATE ONLY AND HAVE c9 NOT BEEN INDEPENDENTLY VERIFIED BY THE GIA ENTERPRISES OWNER OR ITS REPRESENTATIVE. THE WORKMAN ARLENE M. 0323059097 CONTRACTOR SHALL DETERMINE THE EXACT 0323059055 LOCATION OF ALL EXISTING UTILITIES BEFORE w COMMENCING WORK AND AGREES TO BE FULLY 12"FIR -'- J RESPONSIBLE FOR ANY AND ALL DAMAGES THAT o M = HAPPEN DUE TO THE CONTRACTOR'S FAILURE �� TO LOCATE EXACTLY AND PRESERVE ANY AND o FIz ALL UNDERGROUND UTILITIES. AHBL ASSUMES 24"R .: � Q NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. 20' SEWER EASEMENT 16711 i i TOPOGRAPHIC NOTE 20"FI n THE EXISTING CULTURAL AND TOPOGRAPHIC �, DATA SHOWN ON THESE DRAWINGS HAS BEEN 16"FIRf�'•�•� W PREPARED, IN PART, BASED UPON INFORMATION'' 30" FIR FURNISHED BY OTHERS. WHILE THIS O / INFORMATION IS BELIEVED TO BE RELIABLE, - 40.00' STREAM AHBL CANNOT ENSURE ACCURACY AND THUS IS 24" FIR / W / NOT RESPONSIBLE FOR THE ACCURACY OF W W / THAT INFORMATION OR FOR ANY ERRORS OR W W W W / BUFFER OMISSIONS WHICH MAY HAVE BEEN 14"FIR I W W W / WF A8 I INCORPORATED INTO THESE DRAWINGS AS A W / JVF A7 WF AA8'. RESULT. FILL SPECIFICATION IMPORTED FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH OTHERWISE VIOLATE ANY STATE, FEDERAL, OR LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE, ORDER, OR STANDARD. Know what's below. Call before you dig. 16"FI W F A6 164.55' N89° 37' 58"W 0" Fir WF A5 W F / 18" 30"F W F AA51 WFA3, . - .4 / / TACOMA S E A T T L E �� S P O K A N E T R I- C I T I E S ���.5kEClSTER�9 �� �SSIONAL E2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 07/21 /2025 _1_y__ BECK HOLDINGS LLC 0323059044 ROCKERY SHEET INDEX PAGE # SHEET # SHEET TITLE 1 C0.1 COVER SHEET 2 C1.1 TESC AND DEMOLITION PLAN 3 C1.2 TESC NOTES AND DETAILS 4 C1.3 TESC NOTES AND DETAILS 5 C2.1 GRADING PLAN 6 C3.1 FRONTAGE IMPROVEMENTS PLAN 7 C3.2 FRONTAGE IMPROVEMENTS DETAILS 8 C3.3 FRONTAGE IMPROVEMENTS DETAILS 9 C4.1 STORM DRAINAGE PLAN 10 C4.2 SITE SECTIONS 11 C4.3 STORM NOTES AND DETAILS 12 C4.4 STORM NOTES AND DETAILS 13 C4.5 STORM NOTES AND DETAILS 14 C4.6 STORM NOTES AND DETAILS 15 C4.7 STORM NOTES AND DETAILS 16 C4.8 STORM NOTES AND DETAILS 17 C4.9 STORM NOTES AND DETAILS 18 C5.1 UTILITY PLAN 19 C5.2 SEWER NOTES AND DETAILS 20 C5.3 SEWER NOTES AND DETAILS 21 C5.4 WATER NOTES AND DETAILS 22 C5.5 WATER NOTES AND DETAILS 23 C5.6 WATER NOTES AND DETAILS 24 C5.7 WATER NOTES AND DETAILS 25 C6.1 HORIZONTAL CONTROL & SURFACING PLAN 26 C6.2 SURFACING NOTES AND DETAILS 27 C7.1 COMPOSITE UTILITY PLAN 28 C8.1 GARBAGE TRUCK TURNING EXHIBIT 29 L1.00 LANDSCAPE PLAN 30 L1.01 PLANT LEGEND AND IMAGES 31 L1.02 PLANTING DETAILSS 32 P1.0 PHOTOMETRIC CALCULATIONS 33 IL1.0 ILLUMINATION PLAN 34 IL1.1 ILLUMINATION DETAILS 7__ C/) co co w w Of NF gvN 0 NE 12TH ST Q co SI E m m VICINITY MAP 1" = 1/4 MILES LEGEND EXISTING DESCRIPTION PROPOSED MONUMENT LIGHT -0- POWER/TELE. POLE E__ GUY WIRE O TELEPHONE MH ❑ TELEPHONE RISER ® CATCH BASIN ■ OO DRAIN MH Q■ CLEANOUT SANITARY MH SIGN HYDRANT FIRE DEP'T CONNECTION WATER VALVE W WATER METER TRAFFIC SIGNAL BOX SIGNAL POLE WIRE FENCE CHAIN LINK FENCE -0-0-0-0- WOOD FENCE CONTOURS ELEV ON -SITE CLEARING LIMITS - - - D - - - STORM DRAIN LINE D ---W--- WATERLINE W - - - S - - - SANITARY SEWER LINE S ROOF DRAIN LINE RD PROPOSED PAVING WASTEWATER UTILITY REGIONAL FIRE AUTHORITY 4G'S T�ti jstowell 07/28/2025 APPROVED cthomas 07/28/2025 °0" R-433501 U �, LO O 0 N KOC O O i N Q J III') co It i 0 w �1 L FOUND INVERTED NAIL IN a2$o�1lGl(1 CONCRETE POST, INCASED ,S i ' SANITARY SEWER / IP MANHOLE RIM 400.93 8" CONC N 391.53 IE 12" CONC NE 390.88 IE 0 6" CONC S 391.82 IE 12 CONC SW 390.90 IE •0 % CATCH BASIN V REMOVE DRIVWAY RIM 400.78 ��� / 12" CONC SW 397.38 IE REMOVE DRIVWAY, REMOVE AN6 CL i i REMOVE AND REPLACE CURB AS REPLACE CURB AS -REQUIRED REQUIRED REMOVE EXISTING `'�psPNP� �' / ' / ✓�/ / /a METER, EXISTING SANIT SEWER MANHOLE �i S SL SERVICE LINE OBE RI 0.71 '' i ✓ REMOVE SIDEWALK CUT AND C " CONC N 88.80-IE- '' i /� TO NEAREST JOINT CATCH BASIN '' W \ 12" CONC .61 1 S / AT MAIN BY CITY � / RIM 400.13 FORCES, CUT AND CAP 12" CONC SW 397.30 IE / ' \ PERMIT REQUIRED CATCH BASIN �1 S i J GRAV SIGNAL BQ< �-- RIM 398.80 F 2�,� EM_Q SIDEWALK i ' / / / \- 'ALONG FRONTAGE / T.E.S.C. LEGEND CE TEMPORARY CONSTRUCTION ENTRANCE PER RENTON DETAIL 215.10 2 C1.; IP STORM DRAIN INLET PROTECTION PER RENTON DETAIL 216.30 3 C1.2 SF SILT FENCE PER RENTON DETAIL 214.00 1 C1.2 CP CLEAR PLASTIC COVERING, SEE PLASTIC COVERING NOTES ON SHEET C1.2 TS TEMPORARY SEEDING, SEE HYDROSEEDING NOTES CL CLEARING LIMITS VR NATURAL VEGETATION RETENTION OPROTECT UTILITY AND BRING TO GRADE SL SAWCUT LINE 12" CONC NE 394.86 IE 1�� 6 � � � � �� 35 D�0 � - ' - � � - 12 CONC N394.841E �,0\- N6 - s INSPECTION SCHEDULE FOR ESC FACILITIES 12" CONC SW 394.91 IE OPN G� ' P ��P\p,C EROSION CONTROL AND SEDIMENT CONTROL (ESC) FACILITIES SHALL NOT BE ALLOWED TO FALL INTO %� ��\ l S ' ✓ / I DISREPAIR. ALL ESC FACILITIES SHALL BE INSPECTED AS A MINIMUM, ACCORDING TO THE FOLLOWING ✓ \ 0) SCHEDULE: SANITARY SEWER 5g5 10 l' / �0� �� �O� % / i MANHOLE ✓ \�P' i RIM 400.4 p S `� � G o y�, 2� / //� J / DRY SEASON: ONCE A WEEK i 12" CONC NE 38 IE 00 LSCn WET SEASON: DAILY AND AFTER EVERY RAINFALL EVENT PRODUCING RUNOFF. 8.91 P8" PVC 1-,-//EMOVE 2" CO 1J - _ RE E SIDEWACK 001 GUARD R - NEEDED REPAIRS SHALL BE MADE WITHIN 24 HOURS OR IMMEDIATELY IF POSSIBLE. NEA T JOINT / TS CATC ASIN S �O M 399.93 1 P !! � / 12 C NE 395.331E �� T.E.S.C. GENERAL NOTES: 1 ONC SW 395.2 / EMOVE GUARD jo r2, 1. AT A MINIMUM, ALL T.E.S.C. FEATURES SHALL BE INSPECTED AND MAINTAINED PER THE SCHEDULE RAIL U P PROVIDED ON THIS SHEET. 2. TREES TO BE PROTECTED SHALL BE SURROUNDED BY CONSTRUCTION FENCING AT THE DRIP LINE. 4 �q� �� ANY CLEARING REQUIRED INSIDE THE DRIP LINE SHALL BE PERFORMED BY HAND TO PREVENT CE DAMAGE TO THE ROOTS. IF ROOTS GREATER THAN 1" IN DIAMETER ARE DAMAGED DURING g35� N CLEARING OR GRADING, THEY SHALL BE SEALED WITH EMULSIFIED ASPHALT AND COVERED WITH 39 WET BURLAP TO PREVENT THE ROOTS FROM DRYING OUT PRIOR TO BE RECOVERED. COVER EXPOSED ROOTS WITH SOIL AS SOON AS PRACTICABLE. 00 CL TS M Q ✓ER FUTURE BUILDING CONSTRUCTION SEQUENCE 3.25 OUTLINE (TYP.) M S Q 3.LE rt 0 IE ��� 1. SURVEY AND FLAG CLEARING LIMITS. 5 IE 2. SCHEDULE AND ATTEND PRECONSTRUCTION MEETING WITH CITY OF RENTON. 3. PROVIDE MISC. DEMOLITION AND CLEAR AND GRUB AREA WITHIN CLEARING LIMITS REMOVE TREE �':R: a:.' REQUIRED FOR INSTALLATION OF TEMPORARY EROSION CONTROL FACILITIES. ALL �FIR CONTRACTOR TO STABILIZE PROTECT EXISTING EROSION AND SEDIMENT CONTROL FACILITIES SHOWN ON THE EROSION CONTROL '� •2 " CP ALL DISTURBED PORTIONS / TS I, FENCE DURING PLAN SHALL BE INSTALLED PRIOR TO, OR AS A FIRST STAGE OF SITE PREPARATION. O1 OF THE SITE USING SEED, ' CONSTRUCTION U) L MULCH, OR OTHER 4. PROVIDE CONSTRUCTION ENTRANCE, SILT FENCE, AND CATCH BASIN INLET ENGINEER APPROVED BMP. / 11 PROTECTION AS SHOWN ON SHEET C1.2. FILL SLOPE _39", CL CATCH LINE (TYP.) O 5. THE CONTRACTOR SHALL INSPECT EROSION CONTROL MEASURES WEEKLY AND WORKMAN ARLENE M. TEMPORARY SOIL PROVIDE REPAIRS AS NEEDED. 0323059055 U) STOCKPILE AREA, SEE AFTER CB IP * CIA ENTERPRISES 6. PROVIDE COVER MEASURES TO INCLUDE ARMORING, MULCHING AND / STOCKPILE NOTES ON INSTALLATION 0323059097 HYDROSEEDING TO STABILIZE DENUDED AREAS AND PREVENT THE TRANSPORT OF 12"FIR@ - / SHEET C2.2 J SEDIMENT -LADEN STORMWATER OFF -SITE. Grp Q 7. PROVIDE STORM SYSTEM, SANITARY SYSTEM, WATER AND MISCELLANEOUS FILL SLOPE UTILITIES AS SHOWN ON THE PLANS. PROVIDE 6" VERTICAL AND 3' HORIZONTAL 24"FIR O lop\39 AFTER CB IP TYP. SF CATCH LINE (TYP.) CLEARANCE (OUTSIDE SURFACES) BETWEEN STORM DRAIN LINES AND OTHER :': / INSTALLATION UTILITY PIPES AND CONDUITS. 20' SEWERfYP SF 167I 1 � � 3gB / _ i 8. PROVIDE CATCH BASIN SEDIMENT PROTECTION ON ALL CATCH BASINS. PROVIDE CONSTRUCTION IP AFTER CB i PROVIDE CONSTRUCTION FENCE AROUND TREE // J INSTALLATION FENCE AROUND TREE 9. AFTER SITE IS STABILIZED, COMPLETE BIO-RETENTION CONSTRUCTION: DRIPLINE TO PROTECT 0"FI /Cf) i 39'I / / i.,�� - - DRIPLINE TO PROTECT 9.1. SCARIFY ALL BIO-RETENTION SUB -GRADES (DO NOT COMPACT DURING CONSTRUCTION I / 0 3g$ 3 / DURING CONSTRUCTION BIO-RETENTION BOTTOMS) 16"FIR / - - -396_ 9.2. SCHEDULE GEOTECHNICAL ENGINEER FOR INFILTRATION TESTING TO / / �• 30" IR PROVIDE SELECT CLEARING ENSURE TESTING TO INCLUDEN FUNCTION PER DESMINIMUM OF 2 TESTSIPER BRO-RETENTION SY INFILTRATIONOVIDE EM. ✓ / I AS REQUIRED FOR STORM _ 3 6j • VR INSTALLATION INFILTRATION TESTING PER PIERCE COUNTY STORMWATER MANAGEMENT O AND SITE DEVELOPMENT MANUAL. CITY MUST BE NOTIFIED AT LEAST 2 24" FIR :;:;:;:;I: :;:;.;\\ I / 40.00' STREAM / / \ BUSINESS DAYS PRIOR TO INFILTRATION TESTING. BUFFER �� �394- 48" CMP CULVERT 9.3. UPON APPROVAL OF INFILTRATION TESTING RESULTS, PROVIDE �393- - /Vdf 8 T 389.11 IE _ BIO-RETENTION TREATMENT SOIL MIX PER PLANS. BIO-RETENTION SOIL MIX 14"FIR \ �co- / �� 'i PLACEMENT AND BIO-RETENTION EXCAVATION SHALL NOT BE CONDUCTED �✓ �� ` DURING WET OR SATURATED CONDITIONS. SANITARY SEWER MANHOLE �. / / ��i J 9.4. PROVIDE LANDSCAPE PLANTINGS AND FINAL BIO-RETENTION STABILIZATION RIM 396.32 / `^/ 8 PVC S 393.35 IE 1 VR -/ _ F � '' ,l / / PER LANDSCAPE DESIGN. 8" PVC SE 393.38 IE /�'/ • , , 8" PVC N 393.27 IE 164.55' - - - T N89° 37' / 1 10. FINE GRADE SITE AND PAVE. COORDINATE WITH THE CITY FOR REQUIRED - 58 "W F / ✓i/ ✓ - - INSPECTIONS. VR �95 SF TYP . ✓� / i/ / �� = ROCKERY PROVIDE CONSTRUCTION 0" Fir O ,� CL �W.P5✓%, 5' ��%%�/ FENCE AROUND TREE 6"FI�g� �S°��' /j BECK HOLDINGS LLC 11. REMOVE SEDIMENT FROM STORM PIPES AND CATCH BASIN SUMPS. DRIPLINE TO PROTECT I �q� FILL SLOPE _ % i /� / i 30"F r fCH LINE (TYP_ fiidVF A�C5Y ✓ / / / / 0323059044 12. STABILIZE ALL REMAINING DISTURBED AREAS. DURING CONSTRUCTION I r / / -392- ^ - - j /✓ / / / i/ 8" CONCRETE CULVERT WF A 1• - i / ��� 393.56 IE 13. COORDINATE WITH THE CITY OF RENTON FOR FINAL INSPECTION. W F1-1 J l /14. REMOVE REMAINING TEMPORARY EROSION CONTROL DEVICES WHEN AREA HAS BEEN PERMANENTLY STABILIZED WITH VEGETATION AND REMOVAL IS APPROVED `V T • x� j BY THE CITY. OpF WASOG - SURVEYED: SCALE:` O TACOMA SEATTLE S P O K A N E T R I- C I T I E S TER S lkEC�9 Know what's below. �SSIOT E2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Call before you dig. 07/21/2025 LANDUSE CONDITION OF APPROVAL GRAPHIC SCALE 0 10 20 40 1" = 20 FEET 1. THE APPLICANT SHALL RETAIN EITHER THE 29-INCH (29") DBH DOUGLAS FIR TREE OR THE 27-INCH (27") DBH DOUGLAS FIR TREE IDENTIFIED IN THE ARBORIST REPORT SUBMITTED WITH THE APPLICATION. 2. A SCREENING DETAIL FOR ANY PROPOSED SURFACE OR ROOF MOUNTED UTILITY EQUIPMENT BE SUBMITTED TO THE CURRENT PLANNING PROJECT MANAGER FOR REVIEW AND APPROVAL. THE SCREENING DETAIL FOR SURFACE MOUNTED UTILITY EQUIPMENT THAT INCLUDES CROSS SECTIONS OF THE UTILITY AND SCREENING SHALL BE PROVIDED AT THE TIME OF CONSTRUCTION PERMIT REVIEW. 3. THE APPLICANT SHALL SUBMIT A LETTER FROM THE GARBAGE AND RECYCLING SERVICE PROVIDER APPROVING THE LOCATION OF THE ENCLOSURE. THE LETTER SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO CIVIL CONSTRUCTION PERMIT ISSUANCE. 4. A BICYCLE PARKING DETAIL BE SUBMITTED AT THE TIME OF BUILDING PERMIT REVIEW FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER DEMONSTRATING THAT THE PROPOSAL WOULD COMPLY WITH THE BICYCLE PARKING REQUIREMENTS AS REQUIRED IN RMC 4-4-080F.11. 5. THE APPLICANT SHALL SUBMIT A LIGHTING PLAN THAT DEMONSTRATES COMPLIANCE WITH RMC 4-4-075 AND PROVIDES ENOUGH LIGHT FOR SECURITY BUT DOES NOT CREATE EXCESSIVE LIGHT IMPACTS ON NEIGHBORING PROPERTIES. IN ADDITION, THE PARKING AND PEDESTRIAN AREAS SHALL ALSO CONTAIN ADEQUATE LIGHTING TO ENSURE SAFETY AND SECURITY. THE LIGHTING PLAN SHALL INCLUDE DETAILED SHEETS OF ALL EXISTING AND NEW LIGHT FIXTURES ON SITE, FOOTCANDLE ILLUMINATION INFORMATION, AND SHALL BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO CIVIL CONSTRUCTION PERMIT ISSUANCE. 6. THE APPLICANT SHALL PROVIDE A SERVICE AREA SCREENING DETAIL AT THE TIME OF BUILDING PERMIT REVIEW DEMONSTRATING THAT THE SERVICE ELEMENT DOORS WOULD BE SELF- CLOSING. 7. THE SECTION OF THE ON -SITE SIDEWALK BETWEEN THE PUBLIC SIDEWALK IN NE SUNSET BLVD AND THE PLAZA AREA NEAR THE MAIN ENTRANCE SHALL HAVE A MINIMUM WIDTH OF SIX FEET (6'). 8. THE APPLICANT SHALL INSTALL TWO (2) BENCHES, OR AN ALTERNATIVE SEATING OPTION, NEAR EITHER THE FRONT OR ADJACENT REAR ENTRANCE OF THE BUILDING. THE SITE FURNITURE LOCATIONS AND DETAILS DEMONSTRATING COMPLIANCE WITH THE DESIGN STANDARDS SHALL BE PROVIDED WITH THE BUILDING PERMIT APPLICATION FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT MANAGER. 9. THE APPLICANT SHALL SUBMIT A MATERIALS BOARD TO THE CURRENT PLANNING PROJECT MANAGER AT THE TIME OF BUILDING PERMIT REVIEW FOR REVIEW AND APPROVAL. 10. THE APPLICANT SHALL SUBMIT AN INTERNAL TRAFFIC CIRCULATION ANALYSIS THAT DEMONSTRATES HOW VEHICLES WOULD SAFELY ENTER AND EXIT THE PARKING LOT ON THE SITE. THE ANALYSIS SHALL EVALUATE TURNING MOVEMENTS BOTH INTO AND OUT OF THE STALLS, AS WELL AS IDENTIFY WHERE DRIVERS COULD SAFELY TURNAROUND ON THE SITE IF ALL PARKING STALLS WERE FILLED. THE ANALYSIS SHALL BE REVIEWED OR APPROVED PRIOR TO ISSUANCE OF THE CIVIL CONSTRUCTION PERMIT. 11. THE APPLICANT SHALL SUBMIT AN UPDATED SITE PLAN IDENTIFYING A LOADING AND DELIVERY AREA SEPARATE FROM THE CUSTOMER/EMPLOYEE PARKING AND PEDESTRIAN AREAS. THE UPDATED SITE PLAN SHALL BE REVIEWED AND APPROVED BY THE CURRENT PLANNING PROJECT MANAGER PRIOR TO CONSTRUCTION PERMIT ISSUANCE. 12. THE APPLICANT SHALL SUBMIT A SIGNED AND SEALED LETTER FROM A LICENSED GEOTECHNICAL ENGINEER STATING THAT THEY HAVE REVIEWED THE CONSTRUCTION PLANS AND, IN THEIR OPINION, THE PROPOSED PLANS AND SPECIFICATIONS MEET THE INTENT OF THE REPORT. THE LETTER SHALL BE SUBMITTED TO THE CURRENT PLANNING PROJECT MANAGER PRIOR TO ISSUANCE OF THE CIVIL CONSTRUCTION PERMIT. 13. THE APPLICANT SHALL PROVIDE DOCUMENTATION OF THE EXISTING 20-FOOT (20') WIDE SEWER EASEMENT ON THE SITE. THE DOCUMENT SHALL BE REVIEWED AND APPROVED BY THE PUBLIC WORKS PLAN REVIEWER PRIOR TO ISSUANCE OF THE CIVIL CONSTRUCTION PERMIT. IF NO EASEMENT IS FOUND TO EXIST, THE APPLICANT SHALL ESTABLISH A NEW SEWER EASEMENT PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR THE NEW BUILDING. THE LOCATION, SIZE, AND LANGUAGE OF THE EASEMENT SHALL BE REVIEWED AND APPROVED BY THE PUBLIC WORKS PLAN REVIEWER PRIOR TO ISSUANCE OF THE CIVIL CONSTRUCTION PERMIT. IN ADDITION, A PAVED ACCESS ROAD TO THE EXISTING SEWER MANHOLE (COR FACILITY ID MH 3619) WITHIN THE 20 FEET WIDE EASEMENT SHALL BE PROVIDED. NO STRUCTURES SHALL BE INSTALLED WITHIN THE EXISTING EASEMENT, AND THE PROPOSED BIORETENTION CELL SHALL BE LOCATED OUTSIDE OF THE EXISTING PUBLIC UTILITY EASEMENT. 14. THE PROPOSAL SHALL CONFORM TO ALL RECOMMENDATIONS MADE IN THE APPLICANT'S STREAM STUDY AND BUFFER MITIGATION PLAN, PREPARED BY WETLAND RESOURCES, INC., DATED MAY 30, 2024 EXHIBIT 13). R-433502 N co Cfl O N U �, O O i N V% O O O N Q D J L0 C'D It I 0 Uj DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 JOINTS IN FILTER FABRIC SHALL BE SPLICED AT POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS 2"x2" 14 GAUGE WIRE, OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC 2' MIN. DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 R=25'MIN. EX�S�\NOROPo CONSTRUCTION ENTRANCE NOTES: 1. DRIVEWAYS SHALL BE PAVED TO THE EDGE OF THE RIGHT-OF-WAY RI PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY. \ 2. IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD INSTALL DRIVEWAY CULVERT 6 MAX. I I I 12" MIN. IF THERE IS A ROADSIDE PO O 8' SPACING WIRE BACKING S USED I I 4 x4" MIN. TRENCH I I DITCH PRESENT, AS PER CITY I'UII ROAD STANDARDS BACKFILL TRENCH WITH NATIVE SOIL OR 3/4" TO 1-1/2" WASHED GRAVEL 4"-8" QUARRY SPALLS 2"x4" WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP.) %SECTION VIEW DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 SEDIMEN NOTES: 1. CONDITIONS OF USE 1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. AOS (ASTM D4751) 30-100 SIEVE SIZE (0.60-0.15mm) FOR SILT FILM 50-100 SIEVE SIZE (0.30-0.15mm) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D4491) 0.02 SEC' MINIMUM GRAB TENSILE STRENGTH (ASTM D4632) 180 LBS. MIN. FOR EXTRA STRENGTH FABRIC 100 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM D4632) 30% MAX. (WOVEN) ULTRAVIOLET RESISTANCE (ASTM D4355) 70% MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V 2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4"X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 3.4. SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NITS) PUBLIC WORKS STD. PLAN - 214.00 PRO DEPARTMENT SILT FENCE GAZ 9/28/2018 Public Works Adminl#rato, DATE SILT FENCE NOT TO SCALE PLASTIC COVERING NOTES: 1. PLASTIC SHEETING SHALL HAVE A MINIMUM THICKNESS OF 6 MILS AND SHALL MEET THE REQUIREMENTS OF THE STATE STANDARD SPECIFICATIONS SECTION 9-14.5. 2. COVERING SHALL BE INSTALLED AND MAINTAINED TIGHTLY IN PLACE BY USING SANDBAGS OR TIRES ON ROPES WITH A MAXIMUM 10-FOOT GRID SPACING IN ALL DIRECTIONS. ALL SEAMS SHALL BE TAPED OR WEIGHTED DOWN FULL LENGTH AND THERE SHALL BE AT LEAST A 12 INCH OVERLAP OF ALL SEAMS. 3. CLEAR PLASTIC COVERING SHALL BE INSTALLED IMMEDIATELY ON AREAS SEEDED BETWEEN NOVEMBER 1 AND MARCH 31 AND REMAIN UNTIL VEGETATION IS FIRMLY ESTABLISHED. 4. WHEN THE COVERING IS USED ON UN -SEEDED SLOPES, IT SHALL BE KEPT IN PLACE UNTIL THE NEXT SEEDING PERIOD. 5. PLASTIC COVERING SHEET SHALL BE BURIED TWO FEET AT THE TOP OF SLOPES IN ORDER TO PREVENT SURFACE WATER FLOW BENEATH SHEETS. 6. PROPER MAINTENANCE INCLUDES REGULAR CHECKS FOR RIPS AND DISLODGED ENDS. Know what's below. Call before you dig. �+ T . kr WASg j�� r 4o-k kECISTER�9 w �SSIONAL 07/21 /2025 :45 An SOIL STOCKPILE NOTES: GEOTEXTILE 15MIN. PROVIDE FULL WIDTH OF INGRESS/EGRESS AREA 12" MIN. THICKNESS NOTES: 1. CONDITION OF USE 1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. 1.2. FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION ENTRANCE. STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTHANIDTH TO PROVIDE VEHICLE ACCESS/PARKING, BASED ON LOT SIZE/CONFIGURATION. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXTILE SHALL MEET THE FOLLOWING STANDARDS: GRAB TENSILE STRENGTH (ASTM D4632) 200 LBS. MIN. GRAB TENSILE ELONGATION (ASTM D4632) 30% MAX. (WOVEN) CBR PUNCTURE STRENGTH (ASTM D6241) 495 LBS. MIN. AOS (ASTM D4751) 20-45 (U.S. STANDARD SIEVE SIZE) 2.2. DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABILIZATION BECAUSE THESE PRODUCTS RAISE pH LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED. 2.3. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT. 2.4. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE. 2.5. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE. 3. MAINTENANCE STANDARDS 3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. 3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, OR THE INSTALLATION OF A WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND. 3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET, EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS. 3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NITS) STD. PLAN - 215.10 VAR)PUBLIC WORKS APPROVED: DEPARTMENT STABILIZED CONSTRUCTION ENTRANCE GAZ 9/28/2018 Public Works Administrator DATE CONSTRUCTION ENTRANCE NOT TO SCALE 1. STOCKPILES SHALL BE STABILIZED (WITH PLASTIC COVERING OR OTHER APPROVED DEVICE) DAILY BETWEEN NOVEMBER 1 AND MARCH 31. 2. IN ANY SEASON, SEDIMENT LEACHING FROM STOCK PILES MUST BE PREVENTED. 3. TOPSOIL SHALL NOT BE PLACED WHILE IN A FROZEN OR MUDDY CONDITION, WHEN THE SUBGRADE IS EXCESSIVELY WET, OR WHEN CONDITIONS EXIST THAT MAY OTHERWISE BE DETRIMENTAL TO PROPER GRADING OR PROPOSED SODDING OR SEEDING. 4. PREVIOUSLY ESTABLISHED GRADES ON THE AREAS TO BE TOPSOILED SHALL BE MAINTAINED ACCORDING TO THE APPROVED PLAN. T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB HYDROSEEDING NOTES: :45 AP DRAINAGE GRATE (RECTAN( BI ISOMETRIC VIEW iS 11�.1�9N7� NOTES: 1. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE (BIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE. 5. THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS). 6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15). 8. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) PUBLIC WORKS APPR ED: STD. PLAN - 216.30 PAR) DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 Public Works Administrator DATE CATCH BASIN INSERT NOT TO SCALE 1. HYDROSEEDING SHALL BE APPLIED IN ACCORDANCE WITH THE "EROSION CONTROL 8. THE SEEDBED SHALL BE FIRM WITH A FAIRLY FINE SURFACE, FOLLOWING SURFACE NOTES" ON THIS SHEET. ROUGHENING. PERFORM ALL OPERATIONS ACROSS OR AT RIGHT ANGLES TO THE SLOPE. 2. HYDROSEEDING TO BE THE FOLLOWING MIXTURE: -I'Al 17.2.1.2.K EROSION CON-11101, SEED R711 Common Name/Latin Name % Species Composition Desired Seeds per Square Foot PLS Pounds/Acre Spike bent rass/A rostis exarata 6 9 0.1 California brorrlel8roraus carinatus 15 23 9.8 Tufted hair rass/Descharn sia ces itosa 15 23 0.4 Blue wildr e/Et mus gfaucus 18 27 10.7 California oat rass/Danthonia cafitomica 18 27 5.6 Native red fescue/Fesfuca rubra var. rubra 18 27 2.4 Iwleadow barleyIJ4ordeum brachyantherum 10 15 7:7 3. APPLICATION TO BE 100 LBS/ACRE. 4. 500 LBS/ACRE 10-20-20 FERTILIZER, 2000 LBS/ACRE WOOD FIBER CELLULOSE AND 40 LBS/ACRE SOIL BINDER OR TACKING AGENT TO BE APPLIED WITH SEED MIXTURE. 5. SEED BEDS PLANTED BETWEEN MAY 1 AND OCTOBER 31 WILL REQUIRE IRRIGATION AND OTHER MAINTENANCE AS NECESSARY TO FOSTER AND PROTECT THE ROOT STRUCTURE. 6. FOR SEED BEDS PLANTED BETWEEN OCTOBER 31 AND APRIL 30, ARMORING OF THE SEED BED WILL BE NECESSARY. (E.G., GEOTEXTILES, JUTE MAT, CLEAR PLASTIC COVERING.) 7. BEFORE SEEDING, INSTALL NEEDED SURFACE RUNOFF CONTROL MEASURES SUCH AS GRADIENT TERRACES, INTERCEPTOR DIKES, SWALES, LEVEL SPREADERS AND SEDIMENT BASINS. 9. FERTILIZERS ARE TO BE USED ACCORDING TO SUPPLIERS RECOMMENDATIONS. AMOUNTS USED SHOULD BE MINIMIZED, ESPECIALLY ADJACENT TO WATER BODIES AND WETLANDS. 10. SEED SHALL NOT BE USED IN AREAS SUBJECT TO WEAR BY CONSTRUCTION TRAFFIC MULCHING NOTES: :45 AP 1. MULCH MATERIALS USED SHALL BE HAY OR STRAW, AND SHALL BE APPLIED AT THE RATE OF 2 TONS/ACRE. (MIN. 2" THICK) 2. MULCHES SHALL BE APPLIED IN ALL AREAS WITH EXPOSED SLOPES GREATER THAN 2:1. 3. MULCHING SHALL BE USED IMMEDIATELY AFTER SEEDING OR IN AREAS WHICH CANNOT BE SEEDED BECAUSE OF THE SEASON. 4. ALL AREAS NEEDING MULCH SHALL BE COVERED BY NOVEMBER 1. R-433503 I ` NM t'J C) Nt N LJ �1 N C] C) C) 1 N D J co co It i 0 I..LI 'ED _LY TREE PROTECTION NOTES: 1. A 6-FOOT HIGH TEMPORARY CHAIN LINK FENCE MUST BE PLACED WHERE SHOWN ON PLANS A MINIMUM OF FOUR BUSINESS DAYS PRIOR TO THE COMMENCEMENT OF WORK OR SITE DEMOLITION. VERIFY LOCATIONS WITH CIVIL. NOTIFY THE CLEARING AND GRADING INSPECTOR TO GET BOTH THE INSPECTION AND WRITTEN APPROVAL OF FLAGGED TREES AND TEMPORARY PROTECTION FENCING AROUND TREES TO BE SAVED PER TIME APPROVED PLANS. 2. NO STOCKPILING OF MATERIAL AND NO VEHICULAR TRAFFIC ARE ALLOWED WITHIN THE LIMITS OF THE TEMPORARY FENCING. LIMIT INTRUSION INTO TREE DRIP ZONES WHEN POSSIBLE. FILLING, EXCAVATING. AND CLEARING WITHIN FENCED AREAS MUST BE ACCOMPLISHED BY HAND METHODS ONLY. 3. ROOTS OF TREES TO BE SAVED WHICH ARE DAMAGED DURING CONSTRUCTION! WILL BE TREATED IN THE FOLLOWING WAY' FOR DAMAGED ROOTS OVER 1" IN DIAMETER. MAKE A CLEAN, STRAIGHT GUT TO REMOVE THE DAMAGED PORTION OF THE ROOT. ALL EXPOSED R007S WILL BE TEMPORARILY COVERED WITH DAMP BURLAP OR WOOD SHAVING TO PREVENT DRYING AND COVERED WITH EARTH AS SOON AS POSSIBLE- 4- PER RMC 4-1-130-H.9.f, ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED COMPLETELY AND EVENLY WITH A MINIMUM OF THREE INCHES (Y) OF BARK MULCH PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING. RESTRICTIONS: TREES TO BE PRESERVED SHALL BE DESIGNATED IN ACCORDANCE WITH APPROVED TREE PRESERVATION PLAN ON FILE WITH THE CITY OF RENTON. DESIGNATED TREES WHICH ARE DAMAGED OR DESTROYED SHALL BE REPLACED IN ACCORDANCE WITH RMC 4-4-130 TREE RETENTION AND LAND CLEARING REGULATIONS. OR AS HEREAFTER AMENDED_ TREE PROTECTION FENCING Know what's below. Call before you d �+T T. kr ,: O ,OY WAS, ,; �O kE'ISTEW S CONAL T A C O M A S P O K A N E S E A T T L E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB R-433504 r\ N C') (C) C) O Nt N u �, N LO O O O O i Nt N rr n KOC N C) C) C) N Q D J 07/21 /2025 EARTHWORK SITE AREA: PROPOSED CUT: PROPOSED FILL: FOUND INVERTED NAIL IN Off, �Gl 1 CONCRETE POST, INCASED / SANITARY SEWER MANHOLE 1,590 CU YD (IMPORT) / N� i RIM 400.93 / o 8" CONC N 391.53 IE / 1�? s 12" CONC NE 390.88 IE IE EARTHWORK QUANTITIES PROVIDED ARE FOR PERMITTING / "°�'. �" 1 CONONC S W 390 9 � ' / 12" CONC SW 390.90 IE PURPOSES ONLY, CONTRACTOR SHALL DETERMINE �� CATCH BASIN o EARTHWORK QUANTITIES FOR CONSTRUCTION / / / �� o. / / RIM 400.78 12" CONC SW 397.38 IE STREAM BUFFER /E�>��`°,// EDGE OF STREAM SANIT SEWER MANHOLE - RI � � RI 0.71 / � p "CONC NE388.8_1E-/ STREAM BUFFER CATCH BASIN 12" CONC-S.W3n.61 I RIM 400.13 12" CONC SW 397.30 IE CATCH BASIN ��, Vv `� � / V S � � ®S �IG. AL1 GRAVFL- RIM 398.80 F 12 CONC NE 394.86 IE Nil 5 �N �� \\ \\ / 6 / TWIN 12" CONC N 394.84 IEO N ```�► i i j I 12"CONCSW394.91IE/ �PNT \ \ �-�/ V� 1-1� / / CD � �, l S\(iiG: 401.11 G.r4�13 SANITARY SEWER 9 �0 l �/ / / . ° / r' / i MANHOLE 95' \ S / a%1 / TW:397.87 i RIM 400.4 o \ : 4 1.09 \ ! 6 5�� 2 / , �q B S . 397.87 D i� 12"CONC NE38 IE �� �' i///. "� � l 8"PVC 8.91 IE 'ASP \ \ �/ 1i/ / ° i/ / Cf) / 12" CO W 388 P i \ i �i / 0 / - - _ / ��FG: 400.92 /, a �� / I T 399.50 D / B® / o BW 397.62 FG: 400.88 CATC ASIN S °4 a coo M 399.93 / 2' MSE OR BLOCK FOUND INVERTED NAIL IN 12" C NE 395.33 IE i , / a °. / c 1 ONC SW 395.2 i c' . / � � y WALL, CONTRACTOR CONCRETE POST, INCASED _ el° a a °-�0 DO / / /� TO DESIGN �1 a 00 RIM: 399.82 PROPOSED MEDICAL 1 .0 FG: 399.41 OFFICE SHELL C2.1 FG: 402 a \ 5,200 SF FOOTPRINT FG: 399.29 • FF: 399.50 TW: 399.50 S -F 9.72 399 L FG:399.42 BW: 397.66 CO #3 j TW: 99.43 RIM:399.21 / G:30.41 / a FG:398.88 00 BW: 97.49 G: 398.89 \ 6.63% co TW 397.42 Q SANITARY SEWER / / -' BW 397.42 T- MANHOLE G:39 .32 \ a _ ,3 FG'° FG:399.�9 O co I LS Q RIM 398.25 8� % o FG: 398.42 \\ o 0 12" CONC NE 386.00 IE o �-i FG: 399.20 \ a.° ° 6 12" CONC SW 385.95 IE ° FG: 398.33 0 0 FG: 399.3� . o ° O ACCESSIBLE PARKING 1 0 ° o C6.1 FG:398.33 a ° FG: 398.54 3 FG: 398.24 ° FG: 398.60 CONCRETE F< C4.8 VALLEY GUTTER FG: 398.24 �. ° a ° FG: 39 6 FG: 398.24 FG: 398.15 CB / FG: 2 38.38 RIM: 398.45 FG: 398.43 FG: 3 8.29 FG:398.15 FG:398.26 CO 7 WORKMAN ARLENE M. FG:398.06 15 � RI 397.00 03230590550 I °° GIA ENTERPRISES FG: 397.88 FG: 397.81 NL < 0323059097 FG: 397.83 FG: 98.08 : 398. 7 FG: 397.66 CO #4 On"FIR .: \ RI \�2-3i CB #5 AI RIM:3 7.90 FG:397.77 � 20' SEV'-, CH�)EMENT 16"F CB #2 i / • 9 CB #1 RIM: 397.78 _1/94 20"FI /��� / FG: 398.22 RIM: 98.05 FG: 397.95 p2olo / i 1R"FIRVG: 3 7.75 I S SHEET C4.5 FOR W . 4.37 3�IR WALL ELEVATIONS FG: 397.85 24" FIR W 40.00 STREAM �g5 _ / � 48" CMP CULVERT GRADE AT BACK OF CURB BUFF 8 389.11 IE 14"FIR z , \ ALONG THE BIO-RETENTION /- / -- j� _ _ 9.397.06 °j POND TO BE SET AT TOPS M POND ELEVATION SANITARY SEWER MANHOLE / RIM 396.32 W 00. W W FG: 397.70 `^// 8" PVC S 393.35 IE FG: 397.38 FG: 3_98:5& _Vr 8" PVC SE 393.38 IE 8" PVC N 3q97 IE .3 - FG: 396.33 164.55' 1\189° 37;58"W" j AAgI / FG: 396.54 ROCKERY 0" Fir F .cam- ` 5 �j� BECK HOLDINGS LLC FG: 396.22 30"F I l -393' - % % i , / / /ii / 0323059044 / -392- - r" / // 8" CONCRETE CULVERT - )NFA^1---� � �i% /// �� �/ i/ 393.561E 34,000 SF 0CUYD O �� pF WASgj���Ol 0 O Q Q�� TACOMA SEATTLE 46972 •wSPOKANE TRI-CITIES °A�,s�A'crsT , ' 2215 North 30th Street, Suite 300 Tacoma, WA 98403 Know what's below. SIONAL E� 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Call before you dig. 07/21/2025 DATUM BENCHMARK VERTICAL DATUM = NORTH AMERICAN VERTICAL DATUM NAVD 88 (CITY OF RENTON) CITY OF RENTON SURVEY CONTROL POINT 2189 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY ELEVATION: 400.60' SITE NO.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH END OF 6' CYCLONE FENCE. ELEVATION: 396.77 GENERAL NOTE ALL NEW AND EXISTING POWER AND COMMUNICATION SERVICES SHALL BE UNDERGROUND. PROPOSED BUILDING PROP( GI MSE OR BLOCK WALL, ONTRACTOR TO DESIGN PROPERTY LINE I I EXISTING GRADE 0.25' Y I ORATED FOOTING DRAIN WALL SECTION NOT TO SCALE N GRAPHIC SCALE 0 10 20 40 1" = 20 FEET R-433505 N co O Nt N U �, O O i N V% O O i N Q J Co co It I 0 w CON0 N,q�� c�SFO SANITARY SEWER MANHOLE RIM 398.25 12" CONC NE 386.00 IE 12" CONC SW 385.95 IE CATCH BASIN RIM 398.80 CATCH BASIN 12" CONC NE 394.86 IE RIM 400.13 12" CONC N 394.84 IE 12" CONC SW 397.30 IE 12" CONC SW 394.91 IE 15.00' UTILITY PATCH 3 177.5 LF --D ----D - --D - WATER VAW -W----W----�nl-W--- i I- W--� ---W-- WATER MANHOLE EXISTING 12" GV TYPE C1B CONCRETE 2 - SANITARY SEWER I I DRIVEW Y C3.3 , M- MANHOLE I I 1\163T57'27E 1423.21' (ST) RIM 400.43 CATCH BASIN 12" CONC NE 388.08 IE I TC:400j8 - -401- - - - - RIM 399.93 8" PVC S 388.91 IE 1 FL: 40018 12" CONC NE 395.33 IE 12" CONC SW 388.08 IE ASP A IC3.1 I ::E TCA00.79 TCA00.08 /12" CONC SW 395.21 IE FL: 400.29 �j PROTE T S-T�4uo.5� S S BO��� TC:401�0 EXISTING FL: 400.06 BOX TO GRADE 303.5 LF ^--- ---� ------��- FL_400.50 CMCHBASIN S EG:400.28 WORKMAN ARLENE M. 0323059055 0 v 0 oa � Know what's below. Call before you dig. 20' SEWER EASEMENT ew •• �'T - - , 11' 00 I ! 'R 405 EXISTING ROW BOUNDARY EXISTING GRADE AT SECTION LINE 395 390 LO 0 0 C.� W W----W SANITARY SEWER MANHOLE RIM 400.71 12" CONC NE 388.80 IE 12" CONC SW 388.61 IE ASPHALT C3.1 -BRING SIGNAL BOX TO GRAD€ tO1- - 00, WALK a-400-7� --. �. --P ca e a' �' . � c 5.00' - q 401 - - - - - �-� - -�� 6.50' 405 Ail 8.00, SIDEWALK o�o r, L EXISTING GRADE ELEV. r PROPOSED GRADE ELEV. AT SECTIONNI LINE fill L-%�l ON LINE 00 ai M W U-) rn 0 It 0 0 00 � W 10+00 DRIVEWAY SECTION SCALE: H:1 "=20', V:1 "=2' �+ T . 74 �VO� pg WASk j*N < d�0 SEC 697 TER�O �SSIONAL E��1 07/21 /2025 �11 395 390 M rn M 0 LL 10+50 I CAT PROPOSED MEDICAL OFFICE SHELL 5,200 SF F09TPRINT PROPOSED ROW BOUNDARY PROPOSED GRADE AT SECTION LINE T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 3g9 BENCHMARK DA*CITY VERTICAL DATUM = NORTH AMERICAN VERTICAL DATUM NAVD 88 (CITY OF RENTON) OF RENTON SURVEY CONTROL POINT 2189 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT co 828.07' (C) CENTER OF DRIVEWAY 828 1 1'-(ST-) ELEVATION: 400.60' NE SUNSET BLVD �o �,yp� SITE N0.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF - S - -4R1- -� S - - - - S - - - - S -�cRF F�,oRTFp LIGHT STANDARD, 27' NORTHEAST OF SOUTH TC:401.50 o = OST /1ig74 END OF 6' CYCLONE FENCE. FL: 401.00 11V6gSN Fp ELEVATION: 396.77 - - ---- ---- - - -401- - - - - - - SANITARY SEWER _ - - MANHOLE CATCH BASIN RIM 400.93 8" CONC N 391.53 IE 'T 0 460- . RIM 400.78 12" CONC NE 390.88 IE EG: 12" CONC SW 397.38 IE 6" CONC S 391.82 IE _ - 12" CONC SW 390.90 IE 4& • 11 w 8' 8' z J 28.5' ± BUFFER SIDEWALK w 6" z w 1 MATCH EXISTING U C3.3 GRADE @ 1.5% SAWCUT 2' 1' MAX VARIFS _ \J/ 7" H MA //�\\.��\` EXISTING PAVEMENT 6" CSTC / MATCH EXISTING FLOWLINE GRADE NE SUNSET BLVD SECTION NOT TO SCALE 6.5' 15' 4" CEMENT 2 2" CRUSHED CONCRETE C3.2 SURFACING SIDEWALK TOP COURSE BUILDING WALL N GRAPHIC SCALE 0 10 20 40 1" = 20 FEET R-433506 r\ N CO O Nt N u LO O O I N N O O O N Q D J co co It I 0 w FACE OF CURB 6 1/2'_ 5 1/2" 1" 1/2" R. 1" R. 1:24 ' TOP OF in 1/2" R. ROADWAY 1 r io T V-6" CEMENT CONCRETE TRAFFIC CURB AND GUTTER FACE OF ADJACENT CURB -- 6 112" FLUSH WITH GUTTER PAN AT SIDEWALK RAMP ENTRANCE 1:12 1:24 TOP OF 112" R. ROADWAY 1 in f DEPRESSED CURB SECTION AT SIDEWALK RAMPS 3/8" -r � ' b PREMOLDED JOINT FILLER E FULL -DEPTH EXPANSION JOINT 6" CEMENT CONCRETE 1/2" R. 1" R SIDEWALK RAMP OR LANDING VARIES ` FROM r 6•, TO 0 1 6" 3/B" PREMOLDED JOINT FILLER CEMENT CONCRETE PEDESTRIAN CURB AT SIDEWALK RAMPS AND LANDINGS FACE OF ADJACENT CURB 6 1 /2"`' SEE DEPRESSED CURB DETAIL THIS SHEET 1:24 TOP OF f T 1" 1/2" R. ROADWAY 2" �• I ip r V-6" DEPRESSED CURB SECTION AT RESIDENTIAL DRIVEWAYS ONLY. FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104.2 1/2" R. FACE OF ADJACENT CURB I GUTTER SURFACE T 6 1/2" —5 1/2` y 1" 1"R. FACE OF CURB 8 1/4" s CEMENT CONCRETE TRAFFIC CURB DEPRESSED CURB DETAIL AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS GENERAL NOTES. 1. See standard plans 102 and 101.1 for curb expansion and contraction joint spacing. 2. Expansion joint shall be full depth, 3/8" (in.) premolded joint filler. 3. For Depressed Monolithic Driveway Curb & Gutter Section, see Standard Plan 104.2 TOP OF ROADWAY STD. PLAN — 101 R• PUBLIC WORKS CEMENT CONCRETE CURBS DEPARTMENT CEMENT CONCRETE CURBS NOT TO SCALE Know what's below. Call before you dig. �+ T . kr WASfJj, @� T A C O M A S E A T T L E �f S P O K A N E T R I- C I T I E S ���.5kEClSTER�9 �� �SSIONAL E2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 07/21 /2025 6" RAISED EDGE DETAIL V-0- 6-1 SIDEWALK LEVEL 112- EXTEND SIDEWALK TRANSVERSE 1' - 0 1,-Cr 1/2- (IN) R JOINTS TO INCLUDE RAISED EDGE ROU DING 2.0% 1 1f2-(IN)R (rYP.)- � 1 r� SEE RAISED EDGE LTYPICAL SIDEWALK DETAIL - THIS SHE UNDER SIDEWALK ALL CUT MIN- SLOPES WITH RAISED EDGE U2" (IN) R. UYP.) 2.0% - 1 FOR CURB DETAILS ` 1.5% _ SEE STD PLAN 101 2' - 0' SIDEWALK ADJACENT TO CURB MIN 11 X 1' a. 112" (IN) R. (TYP.) ROU DING _2.0% BRIDGE OR PEDESTRIAN RAILING ADJACENT TO CURB BARRIER - SEE SIDEWALK FOR CURB DETAILS SEE STD PLAN 101. (STEEP FILL SLOPES) CONTRACT PLANS /----WALL OR BARRIER ' I SIDEWALK FLUSH �* 1.5% • • •: ,• • • ••r W- I IN) R. W �• 1�� ••�►7 ��:C VERTICAL WALL - • SEE DETAIL 318- (IN) PREMOLDED JOINT FILLER ADJACENT TO CURB AND RAILING OR WALL B' (IN) PREMOLDED JOINT FILLER FOR SIDE TREATMENT SIDEWALK BUFFER STRIP SIDEWALK ADJACENT TO WALL DETAIL SEE 07RER (SEE NOTE 10) SIDEWALK R. SECTIONS 1 �'N) a 1.5% FOR CURB DETAILS 1.5% MIN. SEE STD PLAN 101 FINISHED GRADE 1- (IN) BELOW TOP OF CONCRETE SURFACE FOR PLANTING - FLUSH IF PAVED - ADJACENT TO BUFFER STRIP NOTES 1. Four feet of the sidewalk width shall be the minimum pedestrian accessible route (PAR) free of vertical and horizontal obstructions. Gratings, Access Covers, Junction Boxes, Cable Vaults, Pull Boxes and other appurtenances within the sidewalk must be flush with surface, and match grade of the sidewalk. 2. Monolithic Cement Concrete Curb and Sidewalk is not permitted In new construction. When replacement work necessitates a Monolithic Cement Concrete Curb build per WSDOT Standard Plan F-30.I0-03. 3. Concrete to be 4,000 PSI. • , p 14 a' 00 / L% 0 I / ell For other referenced NOTES see STD PLAN 104,2. Paved surfaces must comply with STD PLAN 102.1 as applicable. 319- (IN) PREMOLDED JOINT FILLER TYPICAL WHERE APPLJCABLE -FOR CURB DETAILS SEE STD PLAN 101 STING ROADWAY CRUSHEO ROCK BAS CRUSHED SURFACING TOP COURSE (CSTC) COMPACT TO 95%. MODIFIED PROCTOR (UNLESS REQUIREMENT WAIVED BY ENGINEER) TYPICAL UNDER ALL CURB, GUTTER 8 SIDEWALK. CSTC UNDER CURB S GUTTER TO BE 6' THICKNESS OR MATCH EXISTING ROADWAY CRUSHED ROCK BASE, WHICHEVER IS GREATER (TYP. FOR ALL CURB 8 GUTTER). 1 FINISHED GRADE 1• (IN) BELOW TOP OF CONCRETE SURFACE FOR CURB DETAILS SEE STD PLAN 101 e IN SIDEWALK JOINT IN SIDEWALK ONLY FULL -DEPTH EXPANSION JOINT IN BOTH CURB AND SIDEWALK (SEE STD PLAN 101.1) if 3V JOINT AND FINISH DETAIL BROOMED FINISH OR MATCH EXISTING 4` WIDE, SMOOTH TROWELED PERIMETER CEMENT CONCRETE CURB (CURB AND GUTTER SHOWN) FOR CURB DETAILS SEE STD PLAN 101 z 118• TO 114• •� a r � ' C CONTRACTION JOINT JOINT FILLER E FULL -DEPTH EXPANSION JOINT STD PLAN — 109 PUBLIC WORKS DEPARTMENT CEMENT CONCRETE SIDEWALK 1, ;,} I(,'. I;I-) 1.F't'' CEMENT CONCRETE SIDEWALK NOT TO SCALE R-433507 W LJ r� I D J U7 co co It I 0 w r-� 'J n, AAIA1 EXISTING ASPHA PAVEMENT SAWCUT (SEE NOTE 2) ARTERIAL STREET_ MINIMUM 7" HMA (or ACP Class B) (SEE NOTE: 1). OVER 6" CRUSHED ROCK RESIDENTIAL STREET MINIMUM 4" HMA (or ACP Class B) (SEE NOTE 1), OVER 6" CRUSHED ROCK NOTES: 1. MUST MATCH EXISTING THICKNESS IF GREATER. 2. SAWCUT SHALL BE POSITIONED 1' -- 0" BEYOND EDGE OF DAMAGED PAVEMENT. 3. THE INTENT OF THIS DESIGN IS TO DESCRIBE PAVEMENT PLACEMENT AT 'THE GUTTER FACE. SEE STANDARD PLAN FOR CEMENT CONCRETE CURBS. .� STD. PLAN — 103 + �+ PUBLIC WORKS CURB AND GUTTER ~ PPRO D: DEPARTMENT REPLACEMENT DETAILJA fio Are CURB AND GUTTER NOT TO SCALE Know what's below. Call before you dig. �+ T . WASk,kr ,; T A C O M A S E A T T L E �S P O K A N E T R I- C I T I E S .5 AEG STER�9 � �SSIONAL 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 07/21 /2025 — - 810 REM (INCLUDES SIDEWALK RAJAS; _ b r.1 ., )ql ft ?3EE 110TE n b,W+ 10 LF OF PAVED DRNEWAY REOUIRED IF EXPANSIONI JOINT (TYP I �J'S4EESTD' EXPANS'ON JOINT (TYP.I CEA-ENT '.SEE STD PLAN 102: 7. 'PLAN1321 CONCRETE \ (/ SIDEWALK 1 � � SEE NOTE b i yl A cc g W 3 Z Q' kiii+ cc CONSTRUCTION JOW SEE NOTE T CEMENTCOfICAM RA1AP AFTM 12H IV j CURB t GJTTER SLOPE (TYP) (SEE NOTE 1 3'5- CONTRACTION JOINT (TYP (SEE STD PLAN IO21 PLAN VIEW (TYPE C3 S40WN CI d C2 S C-MAX SIMILAR) (SEE NOTE 9) VARIES r l�ffi Wi s 11% VAIL SEF PATE s (riPi . • - 10.1AV1 " - •' • _ _ 10' etN DEPTtf SSE] CURB i GU' TER - \ tc YN (SEE NOTE A scEvrAx DE eWA I:agc11E•E is- E""MON JOSYT MvJ \\\ Tp� SECTICM A ISE! SM R.A Y*% YP.) S"WhK WIDTH 10` CIPPERENCEIN&OPEYA>• - -••ORNEMAI W: SLOPE 1S,.OPE S"OMEXA(WARATED, t bT1 rlwtve DRIVEWAY - t0. MIN tr um DRIVEWAY Wi RELATIVE NEGATIVE SLOPE (AOP6 SE ION SHOWN LXAGCERATED For NOTES see STD PLAN 104.2 I Cir"` AN — 104.4 D. PLAN PUBLIC WORKS CEMENT CONCRETE DRIVEWAY p STD ST'IPL DEPARTMENT ENTRANCE - TYPES CIO, C2139 C313, and C-MAXB (WITH BUFFER)It 4 TYPE C1 B CONCRETE DRIVEWAY NOT TO SCALE Gregg Zimmerman, Public Works Administrator 41 SPECIAL NOTE: IN THE EVENT TRANSVERSE PATCHES EXIST WITHIN THE AFFECTED STREET, THE LENGTH OF THE PATCH SHALL BE EXTENDED TO INCLUDE ANY EXISTING PATCH WITHIN 10 FEET OF THE EDGE OF THE PATCH REQUIRED FOR THE NEW CROSSING AND ANY SUBSEQUENT PATCH EDGE WITHIN 10 FEET OF THE EDGE OF THE SECOND PATCH AND SO ON UP TO A TOTAL OF 300 FEET. TRAFFIC FLOW 2" HMA 2" TO 8" HMA 6.5' MIN. 2" DEPTH OF PLANING OR SAWCUT AND REMOVE VARIES: 6.5' MIN. MIN I MIN r 1VA i IES MIN I MIN / I I 2" SAWCUT AND REMOVE J OR PLANE, SEAL WITH AR-400OW (EACH SIDE) 2" HMA SAWCUT AFTER BACKFILL (EACH SIDE) WIDTH OF TRENCH AS REQUIRED BY SIZE OF PROPOSED IMPROVEMENT (SEE WSDOT STANDARD SPECIFICATION 2-09.4) PLUS AN ALLOWANCE FOR ANY SHORING. SHORING, IF NEEDED, SHALL MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATION 7-08.3(1)B TRENCH WIDTH FACE OF GUTTER OR EDGE OF PAVEMENT CENTER LINE OR LANE LINE DEPTH OF EXISTING PAVEMENT 2" - 6" MIN. HMA (SEE NOTE 2) 6" CRUSHED SURFACING TOP COURSE (CSTC) (9-03.9(3)) PER WSDOT STANDARD SPECIFICATIONS, COMPACTED TO 95% MODIFIED PROCTOR. CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19), GRAVEL BORROW (9-03.14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEOTECH REPORT, COMPACTED TO 95% MODIFIED PROCTOR. PIPE ZONE BEDDING. MATERIAL- SEE STANDARD PLAN 110.1. FOR NOTES, SEE STANDARD PLAN 110.1 TYPICAL TRANSVERSE PATCH FOR STD. PLAN - 110 PUBLIC WORKS FLEXIBLE PAVEMENT OR RIGID F'p Ep D DEPARTMENT PAVEMENT WITH OVERLAY j� r; TRANVERSE PATCH WITH OVERLAY NOT TO SCALE R-433508 r\ N C') (C) O O N U �, LO C) O I N r� Co co i 0 W CATCH BASIN RIM 400.13 12" CONC SW 397.30 IE CATCH BASIN RIM 398.80 12" CONC NE 394.86 IE 12" CONC N 394.84 IE 12"CONC SW394.91 IENPN,L G P� LF 6" CPE .43 @ 643` OUND INVERTED NAIL IN NCRETE POST, INCASED WORKMAN ARLENE M. 0323059055 0 a- rn Know what's below. Call before you dig. CATCHBASIN M 399.93 N E 395.33 IE NC SW 395.21,4E 97 LF 6" CPEP @ 0.50% PERVIOUS CONCRETE OR PERVIOUS PAVING CO #4---, 4 10 LF 6" CPEP @ 0.50% 24"FIR .: CB #2 20' SEWER EASEMENT 16"FIF 27 LF 69,,f REP @ 0.50°/ 5 LF 6" CPEP @ 0.50% CB #3-- I / �0.� kEGISTV w �SSIONAL E��1 07/21 /2025 FLOW LINE TO BE MAINTAINED PER MODIFICATION REQUEST 23' i � CO #2 T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB / FOUND INVERTED NAIL IN CONCRETE POST, INCASED CATCH BASIN RIM 400.78 12" CONC SW 397.38 IE PROPOSED COMMERCIAL BUILDING III � D - REFER TO ARCHITECTURAL PLANS FOR DOWNSPOUT LOCATIONS <ti INSTALL FOOTING DRAIN ALONG WALL BECK HOLDINGS LLC 0323059044 8" CONCRETE CULVERT 393.56 IE 1IOUS CONCRETE ERVIOUS PAVING -6`0 LF 6" CPEP @ 0.83% CONNECT TRASH ENCLOSURE DOWNSPOUT TO BUILDING ROOF DRAIN LINE LF 6" CPEP @ 2.33% - FRENCH DRAIN -CB #4 LF 12" CPEP @ 0.50% 12 LF 6" CPEP @ 3.16% -21 LF 12" CPEP @ 1.37% -19 LF 6" CPEP @ 0.50% DETENTION CHAMBERS 48 LF 12" CPEP @ 1.04% DISCHARGE TO EXISTING STREAM PER HPA PERMIT NUMBER 2025-4-81+01 48" CMP CULVERT 389.11 IE �{ ANTICIPATED HIGH WATER MARK = 392.05 ROCKERY GIA ENTERPRISES 0323059097 1 C4.4 1 C4.3 STORM STRUCTURE TABLE STRUCTURE NAME STRUCTURE DETAILS CB #1 54" TYPE 2 RIM = 398.05 CONTROL STRUCTURE IE = 393.08 (12" S) SOLID LID IE = 393.08 (12" NW) N 618.12 E 953.98 CB #2 RIM = 397.78 NYLOPLAST DRAIN 30" IE = 394.23 (6" SE) SOLID LID IE = 394.64 (6" N) N 611.60 IE = 393.14 (24" NE) E 866.55 CB #3 4'x6' BIOPOD SURFACE VAULT RIM = 394.97 WITH INTERNAL BYPASS IE = 394.40 (6" NE) N 584.71 E 873.84 CB #4 RIM = 398.45 48" TYPE 2 MH IE = 395.00 (6" NW) SOLID LID IE = 394.50 (12" SE) N 661.81 IE = 394.50 (12" SW) E 980.15 CB #5 TYPE 1 RIM = 397.90 BEEHIVE GRATE IE = 394.86 (12" N) N 628.11 E 991.20 CB #6 RIM = 398.44 NYLOPLAST DRAIN 30" IE = 394.40 (12" NE) SOLID LID IE = 393.14 (24" SW) N 658.30 IE = 393.14 (12" SE) E 972.96 CB #7 NYLOPLAST DRAIN 30" RIM = 398.24 SOLID LID IE = 393.08 (12" SE) N 629.70 IE = 393.08 (12" SW) E 946.88 CB #8 RIM = 398.33 TYPE 1 IE = 394.57 (12" S) SOLID LID IE = 395.07 (6" E) N 649.26 IE = 394.57 (12" NW) E 988.22 CO #1 RIM = 399.89 N 778.58 IE = 398.85 (6" SW) E 988.24 CO #2 RIM = 399.82 IE = 397.32 (6" NE) N 733.37 IE = 397.32 (6" SW) E 895.69 CO #3 RIM = 399.21 IE = 395.18 (6" NE) N 718.77 IE = 395.18 (6" S) E 865.79 CO #4 RIM = 397.85 IE = 394.69 (6" S) N 621.39 IE = 394.69 (6" N) E 865.67 CO #5 RIM = 397.66 IE = 394.37 (6" SW) N 587.01 IE = 394.37 (6" NW) E 878.56 CO #6 RIM = 397.45 N 710.04 IE = 395.95 (6" S) E 1000.47 CO #7 RIM = 397.00 IE = 395.45 (6" N) N 650.10 IE = 395.45 (6" S) E 1000.19 IE = 395.45 (6" W) CO #8 RIM = 397.04 N 631.44 IE = 395.54 (6" N) E 1000.11 N GRAPHIC SCALE 0 10 20 40 1" = 20 FEET STREAM BUFFER EDGE OF STREAM STREAM BUFFER BENCHMARK VERTICAL DATUM = NORTH AMERICAN VERTICAL DATUM NAVD 88 (CITY OF RENTON) CITY OF RENTON SURVEY CONTROL POINT 2189 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY ELEVATION: 400.60' SITE NO.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH END OF 6' CYCLONE FENCE. ELEVATION: 396.77 STORM NOTE 1. ALL STORM LINES AND STRUCTURES ON -SITE ARE PRIVATE UNLESS NOTED OTHERWISE 18" 1-1/2" DRAIN ROCK .. • i!►.�.�.�.� SEPARATION FABRIC 6" PERFORATED • - SLOTTED QW54�PIIPP FRENCH DRAIN NOT TO SCALE R-433509 r\ co O Nt N U �, 0 O i 4 .� % N O O O N Q D J LO C') C'7 It i 0 w 405 400 395 390 385 O O O 0 W 10+00 10+50 SIT�ESE CTION 1 SCALE: H:1 "=20', V:1 "=2' U0 v 0 oa � Know what's below. Call before you dig. EXISTING ROW BOUNDARY PROPOSED ROW BOUNDARY 52.00' BUILDING PROPOSED GRADE � \ I I\ I I AT SECTION LINE BIO-RETENTION POND 6" VERTICAL CURB rpm,: EXISTING GRADE T SECTION LINE I I I I BOTTOM OF CHAMBER: 392.75 BOTTOM OF ROCK: 392.00 I I I I 2 DETEN1 C4.5 CHAMBERS ION EX AT STING GRADE PROPOSED GRADE SECTION LINE AT SECTION LINE h7 O LL 00 WLLW Ln 00 O CD ' O O LQ r\ O M coM 0 00 LL W O Cfl r` O co M 00 LL W co r` O co 00 LL W O CD O CO coM LL W Ln N CO CO co�`� LL W N O N CO co LL W 11+00 11+50 pF WASgIN��o�G T A C O M A S E A T T L E ;pC 69 E2.9 SPOKANE TRI-CITIES vdO� SE'W� �SSIONAL E2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 07/21 /2025 405 400 MIN. 4.0' WIDE BERM RETAINING WALL 40'STREAM BUFFER 395 395 BOTTOM OF - CHAMBER: 392.75 1.08' OF DEAD _ STORAGE BOTTOM OF- .)0 390 405 390 385 LL 12+00 400 385 r` O to 0 W CB #1, 54" TYPE 2 CONTROLSTRUC URE SOLID LID N: 618.12 E: 953.98 PROPERTY LINE IE: 393.08 12" (S) IE: 393.08 12" (NW) PROPOSED GRADE 6" VERTICAL CURB AT SECTION LINE I BI -RETENTION POND MIN. 4.0' I E ISTING GRADE WIDE BERM 1.96'yl 40' STREAM BUFFER _ RETAINING _ - WALL F- \ ` I \ 48 _____10.00'j LF 12" CPE 1 nA01Fd&11 \ 14 LF 12" CPEP 0.00 0 H7 2 DETE TION 5 OUTFALL ROTECTION C4.5 CHAM ERS KCT IE:392.58 I I 11 I HIGH WATER MARK = 392.05 CB #7, NYLOPLAST DRAIN 30" SOLID LID OHWL N: 629.70 E: 946.88 EXISTING STREAM RIM: 398.24 IE: 393.08 12" (SE) IE: 393.08 12" (SW) EX STING GRADE PROPOSED GRADE AT SECTION LINE AT SECTION LINE r W f� r, cM C600 O 0)M O 0-)to LLL LLL L L LL W LL W LL W W W 20+00 20+50 SIT�ESE CTION 2 SCALE: H:1 "=20', V:1 "=2' 405 400 395 400 ALL PROTECTION 390 385 LL 21+00 21+25 395 390 O n 0 W VALLEY GUTTER CB #6, NYLOPLAST DRAIN 30" CB #2, NYLOPLAST DRAIN 30" SOLID LID SOLID LID N: 611.60 N: 658.30 E: 866.55 E: 972.96 RIM: 397.78 RIM: 398.44 IE: 394.23 6" (SE) IE: 394.40 12" (NE) IE: 394.64 6" (N) IE: 393.14 24" (SW) IE: 393.14 24" (NE) IE: 393.14 12" (SE) 400 PROPOSED GRADE AT SECTION LINE EXISTING GRADE AT SECTION LINE 1.08' OF DEAD BOTTOM OF CHAMBER: 392.75 DETENTION CHAMBERS 2 C4.5 BOTTOM OF ISTORMTECH EXISTING GRADE AT SECTION LINE PROPOSED GRADE AT SECTION LINE co an 0p L6 co LL W (D � 01 (6 M M LL W ao 00 UC C6 M M LL W op N UC � M LL W - r Lf � M M LL W rn M M U_ W 23+00 23+50 SITE SECTION 3 SCALE: H:1 "=20', V:1 "=2' 24+00 395 Wo co Ln 00 O co C7 LL 24+40 R-433510 r\ N CM (C) O O qqt 6 A u N LO O O N 00 T N O O O i N Q D J LO C') C'7 It I 0 w I — q e� Know what's below. Call before you dig. 4"-6" RECOMMENDED CURB INLET THROAT OPENING CAST -IN PLACE CURB & GUTTER BY OTHERS CURB INLET DETAIL SEE CURB INLET DETAIL THIS SHEET LEFT END VIEW ALTERNATE OUTLET LOCATION M11i 012" RCP MAX. OUTLET INLET CONTOUR RACK WITH PERFORATED FLOOR OPENING TO BIOFILTRATION CHAMBER 18"X36" ACCESS HATCH BYPASS WEIR/OUTLET BAY 6" TOP SLAB - -I— 4'-0" 3'-0" 4X6 BIOPOD SURFACE VAULT WITH INTERNAL BYPASS NOT TO SCALE T @� �i T A C O M A S E A T T L E �46 SPOKANE TRI-CITIES ��of sslGIST 9 Eg�1�� 2215 North 30th Street, Suite 300 Tacoma, WA 98403 ONAL E 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 07/21 /2025 7'-0" 4'-0" -1 PLAN VIEW ELEVATION VIEW ALTERNATE INLET LOCATIONS AVAILABLE CURB INLET WITH 6" NOSING 24"x7" OPENING FOR CURB INLET 36"X36" ACCESS HATCH 2" MULCH 1'-T StormMixTM MEDIA 6" DRAIN ROCK UNDERDRAIN PIPE Bioretention/ Biofiltration NOTES: 1. DESIGN LOADINGS: A. 300 PSF PEDESTRIAN LOADING B. DESIGN SOIL COVER: 0' MAXIMUM C. ASSUMED WATER TABLE: BELOW BASE OF PRECAST (ENGINEER -OF -RECORD TO CONFIRM SITE WATER TABLE ELEVATION) D. LATERAL EARTH PRESSURE: 45 PCF (DRAINED) E. LATERAL LIVE LOAD SURCHARGE: 80 PSF (APPLIED TO 8'-0" BELOW GRADE) F. NO LATERAL SURCHARGE FROM ADJACENT BUILDINGS, WALLS, PIERS, OR FOUNDATIONS. 2. CONCRETE 28-DAY MINIMUM COMPRESSIVE STRENGTH: 5,000 PSI MINIMUM. 3. REINFORCING: REBAR, ASTM A615/A706, GRADE 60 4. CEMENT: ASTM C150 5. REQUIRED ALLOWABLE SOIL BEARING CAPACITY: 2,500 PSF 6. REFERENCE STANDARD: A. ASTM C890 B. ASTM C913 C. ACI318-14 7. THIS STRUCTURE IS DESIGNED TO THE PARAMETERS NOTED HEREIN. ENGINEER -OF -RECORD SHALL VERIFY THAT NOTED PARAMETERS MEET OR EXCEED PROJECT REQUIREMENTS. IF DESIGN PARAMETERS ARE INCORRECT, REVIEWING ENGINEER/AUTHORITY SHALL NOTIFY OLDCASTLE INFRASTRUCTURE UPON REVIEW. 8. INLET AND OUTLET HOLES WILL BE FACTORY CORED/CAST PER PLANS AND CUSTOMER REQUIREMENTS. INLET AND OUTLET LOCATIONS CAN BE MIRRORED. 9. CONTRACTOR RESPONSIBLE TO VERIFY ALL SIZES, LOCATIONS, AND ELEVATIONS OF OPENINGS. 10. CONTRACTOR RESPONSIBLE TO ENSURE ADEQUATE BEARING SURFACE IS PROVIDED (I.E. COMPACTED AND LEVEL PER PROJECT SPECIFICATIONS). 11. SECTION HEIGHTS, SLAB/WALL THICKNESSES, AND KEYWAYS ARE SUBJECT TO CHANGE AS REQUIRED FOR SITE REQUIREMENTS AND/OR DUE TO PRODUCT AVAILABILITY AND PRODUCTION FACILITY CONSTRAINTS. 12. MAXIMUM PICK WEIGHTS": A. TOP: XX,XXX LBS B. BASE: XX,XXX LBS' (' COMBINED WEIGHT OF BASE INCLUDES BYPASS WEIR, DIVIDER WALL, ROCK & MEDIA) 13. INTERNALS SHALL CONSIST OF UNDERDRAIN PIPE, ROCK, STORMMIXTA4 MEDIA, MULCH, AND INLET CONTOUR RACK. R-433511 r\ N CM QD C) O N � U N Ln C) C) I N 00 T N O O I N Q D J Co co It I 0 W q e� Know what's below. Call before you dig. f')111 IKIr% r%t-%X/r r) RIM: 398.05 OUTLET STRUCTURE NOTES 1. METAL PARTS: CORROSION RESISTNAT. NON -GALVANIZED PARTS PREFERRED. GALVANIZED PIPE PARTS TO HAVE ASPHALT TREATMENT. 2. FRAME AND LADDER OR STEPS OFFSET SO: 2.1. CLEANOUT GATE IS VISIBLE FROM TOP. 2.2. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. 3. PROVIDE AT LEAST ONE 3" X 0.090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM T VERTICAL SPACING) 4. REFER TO CITY OF RENTON FLOW CONTROL STRUCTURE STANDARD DETAIL FOR ADDITIONAL NOTES 54-INCH CONTROL STRUCTURE SCALE: 1 "=2' �+ T . kr WASfJj, @� T A C O M A S E A T T L E rt S P O K A N E T R I- C I T I E S ��1069�g���� w� 2215 North 30th Street, Suite 300 Tacoma, WA 98403 NAL E 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 07/21 /2025 _E ..RO. V DocuSign Envelope ID: 3B1 B34D3-7EOA-476C-ADB3-4329FFEOC108 ADDITIONAL LADDER RUNGS (IN SETS) TO 2' MIN. CLEARANCE TO ALLOW ACCESS TO TANKS OR VAULTS ANY PORTION OF FLOW RESTRICTOR �`�l� WHEN CATCH IS FILLED WITH WATER TEE INCLUDING ELBOWS / REMOVABLE WATERTIGHT COUPLING OR FLANGE 2" MIN. I /� /I 1 _ �� \ I I II I l J ELBOW RESTRICTOR, SEE DETAIL AND NOTE 10 I 1 ANGLE AS / NECESSARY, � SEE NOTE 7 6" MIN. 6" MAX. 2' MIN, PLATE WELDED TO ELBOW WITH PLAN VIEW ORIFICE AS SPECIFIED, SEE NOTE 3 ELBOW RESTRICTOR DETAIL ELEVATION PER PLANS FRAME & SOLID COVER MARKED "DRAIN" WITH 12" MIN. UNDER LOCKING BOLTS PER STD. PLANS 204.40 AND 204.50 PAVEMENT =[-�T.IJ,Ji J•]rom 16" MAX. VERTICAL BAR GRATE FOR SECONDARY INLET 6" MIN. LESIUGN WATER ELBOW RESTRICTOR, FACE SEE DETAIL AND NOTE 10 HANDHOLDS, STEPS, OR LADDER PIPE SUPPORTS, SEE NOTE 6 " (TYP.) 1.5 x D SEE NOTE 9 (TYP.) MIN. MIN. — � I I i OUTLET PIPE, SEE INLET PIPE NOTES 1 & 5 2' o MIN. SHEAR GATE WITH CONTROL ROD FOR INVERT AND CLEANOUT/DRAIN (ROD BENT AS REQUIRED ELEVATION PER PLANS FOR VERTICAL ALIGNMENT WITH COVER) 12" SECTION OF PIPE ATTACHED BY 2 PER STD. PLAN 237.30 GASKETED BAND TO ALLOW REMOVAL MIN. 12" 1 WELDED RESTRICTOR PLATE WITH ORIFICE DIA AS SPECIFIED, SEE NOTE 10 a=i` ri rh ki A 1. USE A MIMIMUM OF A 54" DIAMETER TYPE 2 CATCH BASIN. 2. OUTLET CAPACITY: 100-YEAR DEVELOPED PEAK FLOW. 3. METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 4. FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. 5. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4". 6. PROVIDE AT LEAST ONE 3" X .090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM 3'-0" VERTICAL SPACING). 7. LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN. 8. LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER. 9. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10. IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 237.00 c PUBLIC WORKS FLOW CONTROL STRUCTURE - �I� DEPARTMENT RESTRICTOR TEE CITY OF RENTON FLOW CONTROL STRUCTURE DATE 0 1 8: R-433512 r\ N co CO C) O Nt N A, LJ N C) C) I Nt N LL N C) C) C) N Q D J LO C') C'7 It I O 1 0 w / / / BI;OPOD / V_ l V_ V_ V_ V_ V V_ CV) V_ V_ TW: 395.53 BW: 395.53 i V_ C§1 N 581.08 E 900.06 N 581.41 E 897.43 TW: 397.90 BW: 395.73 25.85' 4 INLET C4.9 PROTECTION (TYP.) 4.00' MIN. BERM I-TW: 397.90 BW: 395.80 II 1l��1 II •- � � - ® l� III III III l� III III III III III III Fc PLAN FOR FULL CHAMBER DESIGN 110.78' GRADE AT BACK OF CURB \ ALONG THE BIO-RETENTION Mr ['+rT AT Tl M /'1r STORM LAYOUT SCALE: 1" = 10' 0 v 0 oa � Know what's below. Call before you dig. IT. xrJ o-k kECl9T01 ASV �SSIONAL E��l 07/21 /2025 n T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB INLET 4 PROTECTION C 9 (TYP. ) N 628.11�/_, N 609.59 E 991.20 E 964.64 0.73 N 617.90 E 994.47 ITW: 397.90 BW: 396.13 TW: 397.90 / BW:396.26 / ZETENTION CELL 1 TOM AREA: 478 SF C4.8 ELEV: 396.90 ELEV:397.90 / 4 / / / / �7 GRAPHIC SCALE 0 5 10 1" = 10 FEET 20 PERIMETER STONE (SEE NOTE 4) EXCAVATION WALL (CAN BE SLOPED OR VERTICAL) / / / TW: 396.66 BW: 396.66 / TW: 383 BW: 6.42 12" (300 mm dlf'1TC�. ADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE ALL AROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS 100 END CAP SUBGRADE SOILS J (SEE NOTE 3) PAVEMENT LAYER (DESIGNED BY SITE DESIGN ENGINEER) 1 1 i "TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR, 15, 8 INCREASE COVER TO 21" (525 mm). (2.4 m) MAX (375 mm) MIN' 6" (150 mm) MIN 6" (150 mm) MIN 33" "THIS CROSS SECTION DETAIL REPRESENTS (838 mm) MINIMUM REQUIREMENTS FOR INSTALLATION. PLEASE SEE THE LAYOUT SHEET(S) FOR PROJECT SPECIFIC REQUIREMENTS. II I I li- III— 6" (150 mm) MIN TT (SEE NOTE S) 51" (1295 mm) 12" (300 mm) MIN 1. CHAMBERS SHALL MEET THE REQUIREMENTS OF ASTM F2418, "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 2. SC-800 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 3. THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS. REFERENCE STORMTECH DESIGN MANUAL FOR BEARING CAPACITY GUIDANCE. 4. PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS. 5. REQUIREMENTS FOR HANDLING AND INSTALLATION: • TO MAINTAIN THE WIDTH OF CHAMBERS DURING SHIPPING AND HANDLING, CHAMBERS SHALL HAVE INTEGRAL, INTERLOCKING STACKING LUGS. • TO ENSURE A SECURE JOINT DURING INSTALLATION AND BACKFILL, THE HEIGHT OF THE CHAMBER JOINT SHALL NOT BE LESS THAN 211 . • TO ENSURE THE INTEGRITY OF THE ARCH SHAPE DURING INSTALLATION, a) THE ARCH STIFFNESS CONSTANT AS DEFINED IN SECTION 6.2.8 OF ASTM F2418 SHALL BE GREATER THAN OR EQUAL TO 550 LBS/FT/%. AND b) TO RESIST CHAMBER DEFORMATION DURING INSTALLATION AT ELEVATED TEMPERATURES (ABOVE 73° F / 23° C), CHAMBERS SHALL BE PRODUCED FROM REFLECTIVE GOLD OR YELLOW COLORS. ACCEPTABLE FILL MATERIALS: STORMTECH SC-800 CHAMBER SYSTEMS AASHTO MATERIAL MATERIAL LOCATION DESCRIPTION COMPACTION / DENSITY REQUIREMENT CLASSIFICATIONS FINAL FILL: FILL MATERIAL FOR LAYER'D' STARTS FROM THE PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED D TOP OF THE 'C' LAYER TO THE BOTTOM OF FLEXIBLE ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS. N/A INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND PAVEMENT OR UNPAVED FINISHED GRADE ABOVE. NOTE THAT CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS. PREPARATION REQUIREMENTS. PAVEMENT SUBBASE MAY BE PART OF THE'D' LAYER. AASHTO M145' BEGIN COMPACTIONS AFTER 12" (300 mm) OF MATERIAL OVER GRANULAR WELL -GRADED SOIL/AGGREGATE MIXTURES, <35% FINES OR A-1, A-2-4, A-3 THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN INITIAL FILL: FILL MATERIAL FOR LAYER'C' STARTS FROM THE PROCESSED AGGREGATE. 6" (150 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR C TOP OF THE EMBEDMENT STONE ('B' LAYER) TO 15" (375 mm) OR WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR ABOVE THE TOP OF THE CHAMBER. NOTE THAT PAVEMENT MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS PROCESSED AGGREGATE MATERIALS. ROLLER GROSS SUBBASE MAY BE A PART OF THE'C' LAYER. LAYER. AASHTO M43' VEHICLE WEIGHT NOT TO EXCEED 12,000 Ibs (53 kN). DYNAMIC 3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10 FORCE NOT TO EXCEED 20,000 Ibs (89 kN). EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS CLEAN, CRUSHED, ANGULAR STONE AASHTO M43' B FROM THE FOUNDATION STONE (W LAYER) TO THE 'C' LAYER OR RECYCLED CONCRETE 3, 357, 4, 467, 5, 56, 57 NO COMPACTION REQUIRED. ABOVE. A FOUNDATION STONE: FILL BELOW CHAMBERS FROM THE CLEAN, CRUSHED, ANGULAR STONE AASHTO M43' PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE.z,s SUBGRADE UP TO THE FOOT (BOTTOM) OF THE CHAMBER. OR RECYCLED CONCRETE 3, 357, 4, 467, 5, 56, 57 PLEASE NOTE: 1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE". 2. STORMTECH COMPACTION REQUIREMENTS ARE MET FORA' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 6" (150 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR. 3. WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS. 4. ONCE LAYER'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION. 5. WHERE RECYCLED CONCRETE AGGREGATE IS USED IN LAYERS W OR'B' THE MATERIAL SHOULD ALSO MEET THE ACCEPTABILITY CRITERIA OUTLINED IN TECHNICAL NOTE 6.20 "RECYCLED CONCRETE STRUCTURAL BACKFILL". STORMTECH CHAMBER SYSTEM NOT TO SCALE R-433513 r\ CM N u IN LO O O O i N I..L W T N C) I N Q D J Co co It i 6 0 W I - STORMTECH HIGHLY RECOMMENDS FLEXSTORM INSERTS IN ANY UPSTREAM STRUCTURES WITH OPEN GRATES ELEVATED BYPASS MANIFOLD SUMP DEPTH TBD BY SITE DESIGN ENGINEER NYLOPLAST (24" [600 mm] MIN RECOMMENDED) INSTALL FLAMP ON 24" (600 mm) ACCESS PIPE PART#: SC74024RAMP SC-800 CHAMBER 24" (600 mm) HDPE ACCESS PIPE REQUIRED USE END CAP PART #: SC800EPE24BPC SC-800 ISOLATOR ROW PLUS DETAIL NTS STORMTECH ISOLATOR ROW DETAIL NOT TO SCALE 11 MT1 f-%KIAI I K I C'` n r n T 1/% K l Ml1 M-r SC-800 END CAP N" "., ". -- FOUNDATION WOVEN GEOTEXTILE BETWEEN- FOUNDATION STONE AND CHAMBERS 5' (1.5 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS 6 12.2" (310 mm) SC-800 TECHNICAL SPECIFICATION 46.5" (1181 mm) 51.0" (1295 mm) NOMINAL CHAMBER SPECIFICATIONS 1m) NTS 1m) f-MICCI AC AICVT f'UAr010CE:) UCCC a BUILD ROW IN THIS DIRECTION 85.4" (2169 mm) INSTALLED LENGTH 90.6" (2301 mm) ACTUAL LENGTH SIZE (W X H X INSTALLED LENGTH) 51.0" X 33.0" X 85.4" (1295 mm X 838 mm X 2169 mm) CHAMBER STORAGE 50.6 CUBIC FEET (1.43 m3) MINIMUM INSTALLED STORAGE* 81.0 CUBIC FEET (2.29 m3) WEIGHT 81.81bs. (37.1 kg) UNDERDRAIN DETAIL NTS NOMINAL END CAP SPECIFICATIONS STORMTECH STORMTECH SIZE (W X H X INSTALLED LENGTH) 46.5" X 32.6" X 10.5" (1181 mm X 828 mm X 267 mm) CHAMBERS STORMTECH CHAMBER END CAP STORAGE 3.4 CUBIC FEET (0.09 m3) END CAP MINIMUM INSTALLED STORAGE** 15.4 CUBIC FEET (0.43 m3) WEIGHT OUTLET MANIFOLD 15.71bs. (7.1 kg) FOUNDATION STONE BENEATH CHAMBERS ADS GEOSYNTHETICS 601 NON -WOVEN GEOTEXTIL STORMTECH END CAP FOUNDATION STONE BENEATH CHAMBERS ADS GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE I -1-1 x -- ­L I 1 I I L "I L.,1. 11- I "I x VI I" JESIGN ENGINEER 4" (100 mm) TYP FOR SC-310 & SC-160LP SYSTEMS 6" (150 mm) TYP FOR SC-800, DC-780, MC-3500, MC-4500 & MC-7200 SYSTEMS CHAMBER UNDERDRAIN NOT TO SCALE Know what's below. Call before you dig. �+ T. xrj �VO� pg WASk j*N < � ado,\ SEC T72 �`sSIONAL C1=rT1r)K1 R_R T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB L WALL FORATED E ERDRAIN * ASSUMES 6" (152 mm) STONE ABOVE, BELOW, AND BETWEEN CHAMBERS **ASSUMES 6" (152 mm) STONE ABOVE AND BELOW END CAPS, 6" (152 mm) BETWEEN ROWS, 12" (305 mm) BEYOND END CAPS PRE -CORED HOLES AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "BPC" PRE -CORED HOLES AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "TPC" PART # STUB B C SC800EPE06TPC 6" (150 mm) 21.4" (544 mm) --- SC800EPE06BPC --- 0.9" (23 mm) SC800EPE08TPC 8° (200 mm) 19.2" (488 mm) --- SC800EPE08BPC --- 1.0" (25 mm) SC800EPE10TPC 10" (250 mm) 17.0" (432 mm) --- SC800EPE10BPC --- 1.2" (30 mm) SC800EPE12TPC 12" (300 mm) 14.4" (366 mm) --- SC800EPE12BPC --- 1.6" (41 mm) SC800EPE15TPC 15" (375 mm) 11.3" (287 mm) --- SC800EPE15BPC --- 1.7" (43 mm) SC800EPE18TPC 18" (450 mm) 8.0" (203 mm) --- SC800EPE18BPC --- 2.0" (51 mm) SC800EPE24BPC 24" (600 mm) --- 2.3" (58 mm) SC800EPE NONE SOLID END CAP NOTE: ALL DIMENSIONS ARE NOMINAL CHAMBER SPECIFICATIONS NOT TO SCALE C START END R-433514 r\ t'J CO O O N u �, N O O O O N KOC O O O N Q D J 07/21 /2025 U7 Co co It i 0 w NYLOPLAST DRAIN BASIN NTS INTEGRATED DUCTILE IRON FRAME & GRATE/SOLID TO MATCH BASIN O.D. 12" (610 mm) MIN (FOR AASHTO H-20) INVERT ACCORDING TO PLANS/TAKE OFF VARIOUS TYPES OF INLET AND OUTLET ADAPTERS AVAILABLE: 4-30" (100-750 mm) FOR CORRUGATED HDPE WATERTIGHT JOINT (CORRUGATED HDPE SHOWN) NOTES 18" (457 mm) MIN WIDTH AASHTO H-20 CONCRETE SLAB 8" (203 mm) MIN THICKNESS TRAFFIC LOADS: CONCRETE DIMENSIONS ARE FOR GUIDELINE PUPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED GIVING CONSIDERATION FOR LOCAL SOIL CONDITIONS, TRAFFIC LOADING & OTHER APPLICABLE DESIGN FACTORS ADAPTER ANGLES VARIABLE 00- 3600 ACCORDING TO PLANS VARIABLE SUMP DEPTH ACCORDING TO PLANS [6" (152 mm) MIN ON 8-24" (200-600 mm), 10" (254 mm) MIN ON 30" (750 mm)] 4" (102 mm) MIN ON 8-24" (200-600 mm) 6" (152 mm) MIN ON 30" (750 mm) BACKFILL MATERIAL BELOW AND TO SIDES OF STRUCTURE SHALL BE ASTM D2321 CLASS I OR II CRUSHED STONE OR GRAVEL AND BE PLACED UNIFORMLY IN 12" (305 mm) LIFTS AND COMPACTED TO MIN OF 90% 1. 8-30" (200-750 mm) GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 2. 12-30" (300-750 mm) FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3. DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS 4. DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS & HANCOR DUAL WALL) & SDR 35 PVC 5. FOR COMPLETE DESIGN AND PRODUCT INFORMATION: WWW.NYLOPLAST-US.COM 6. TO ORDER CALL: 800-821-6710 A PART # GRATE/SOLID COVER OPTIONS 8 PEDESTRIAN LIGHT STANDARD LIGHT (200 mm) 2808AG DUTY DUTY SOLID LIGHT DUTY 101, PEDESTRIAN LIGHT STANDARD LIGHT (250 mm) 2810AG DUTY DUTY SOLID LIGHT DUTY 12 PEDESTRIAN STANDARD AASHTO SOLID (300 mm) 2812AG AASHTO H-10 H-20 AASHTO H-20 15" PEDESTRIAN STANDARD AASHTO SOLID (375 mm) 2815AG AASHTO H-10 H-20 AASHTO H-20 18 PEDESTRIAN STANDARD AASHTO SOLID (450 mm) 2818AG AASHTO H-10 H-20 AASHTO H-20 24 PEDESTRIAN STANDARD AASHTO SOLID (600 mm) 2824AG AASHTO H-10 H-20 AASHTO H-20 30" PEDESTRIAN STANDARD AASHTO SOLID (750 mm) 2830AG AASHTO H-20 H-20 AASHTO H-20 NYLOPLAST DRAIN BASIN NOT TO SCALE 99 kEClST sv S CONAL T A C O M A S P O K A N E S E A T T L E T R I- C I T I E S 12" (300 mm) MIN WIDTH 8" (200 mm) MIN THICKNESS OF ASPHALT . OVERLAYAND CONCRETE COLLAR ASPHALT OVERLAY FOR TRAFFIC APPLICATIONS NYLOPLAST 8" LOCKING SOLID COVER AND FRAME CONCRETE COLLAR / ASPHALT OVERLAY NOT REQUIRED FOR GREENSPACE OR NON -TRAFFIC APPLICATIONS 8" NYLOPLAST UNIVERSAL INLINE DRAIN BODY (PART# 2708AG41PKIT) OR TRAFFIC RATED BOX W/SOLID LOCKING COVER 4" (100 mm) SDR 35 PIPE 4" (100 mm) INSERTA TEE TO BE CENTERED ON CORRUGATION CREST NOTE: INSPECTION PORTS MAY BE CONNECTED THROUGH ANY CHAMBER CORRUGATION CREST. 4" PVC INSPECTION PORT DETAIL (SC SERIES CHAMBER) NTS INSPECTION PORT NOT TO SCALE R-433515 , LJ N U7 O O O O N KOC N O O 0 N Q J Know what's below. Call before you d 07/21 /2025 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Co co It i i 0 w SURFACE WATER DRAINAGE NOTES & SPECIFICATIONS 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON PLAN REVIEWER. 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE MOST RECENT "STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION" PREPARED BY W.S.D.O.T., AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS. 3. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS WHICH ARE ON FILE IN THE DEPARTMENT OF PUBLIC WORKS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS OR SURFACE WATER UTILITY. 4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5. DATUM SHALL BE NAVD 88. UNLESS OTHERWISE APPROVED BY CITY OF RENTON DEPARTMENT OF PUBLIC WORKS. REFERENCE BENCHMARK AND ELEVATION ARE NOTED ON THE PLANS. 6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED. 7. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, SURFACE WATER UTILITY. 8. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE DEPARTMENT OF PUBLIC WORKS, SURFACE WATER UTILITY. 9. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-04 OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C", WITH THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95 % FOR PAVEMENT AND STRUCTURAL FILL AND 90% OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6" OVER AND UNDER P.V.C. PIPE. 10. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE. 11. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 12. OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT OF WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY OF RENTON ADMINISTRATOR, DEPARTMENT OF PLANNING/BUILDING/PUBLIC WORKS. 13. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF 1 FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4"-8"/40%-70% PASSING; 2"4' ROCK/30%-40% PASSING; AND -2" ROCK/10%-20% PASSING. 14. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE DEPARTMENT OF DEVELOPMENT SERVICES, PLAN REVIEWER OR SURFACE WATER UTILITY. AN ACCURATELY DIMENSIONED CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY OF RENTON UPON COMPLETION. 15. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMIT BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFT, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE AN APPROVED TRAFFIC CONTROL PLAN BY THE TRAFFIC ENGINEERING DIVISION OF THE DEPARTMENT OF PUBLIC WORKS. ALL SECTIONS OF THE W.S.D.O.T. STANDARD SPECIFICATIONS 1-07-23, TRAFFIC CONTROL, SHALL APPLY. SOIL AMENDMENT • SOIL RETENTION. RETAIN, IN AN UNDISTURBED STATE, THE DUFF LAYER AND NATIVE TOPSOIL TO THE MAXIMUM EXTENT PRACTICABLE. IN ANY AREAS REQUIRING GRADING REMOVE AND STOCKPILE THE DUFF LAYER AND TOPSOIL ON SITE IN A DESIGNATED, CONTROLLED AREA, NOT ADJACENT TO PUBLIC RESOURCES AND CRITICAL AREAS, TO BE REAPPLIED TO OTHER PORTIONS OF THE SITE WHERE FEASIBLE. • SOIL QUALITY. ALL AREAS SUBJECT TO CLEARING AND GRADING THAT HAVE NOT BEEN COVERED BY IMPERVIOUS SURFACE, INCORPORATED INTO A DRAINAGE FACILITY OR ENGINEERED AS STRUCTURAL FILL OR SLOPE SHALL, AT PROJECT COMPLETION, DEMONSTRATE THE FOLLOWING: 1. A TOPSOIL LAYER WITH A MINIMUM ORGANIC MATTER CONTENT OF 10% DRY WEIGHT IN BEDS, AND 5% ORGANIC MATTER CONTENT IN TURF AREAS, AND A PH FROM 6.0 TO 8.0 OR MATCHING THE PH OF THE UNDISTURBED SOIL. THE TOPSOIL LAYER SHALL HAVE A MINIMUM DEPTH OF EIGHT INCHES EXCEPT WHERE TREE ROOTS LIMIT THE DEPTH OF INCORPORATION OF AMENDMENTS NEEDED TO MEET THE CRITERIA. SUBSOILS BELOW THE TOPSOIL LAYER SHOULD BE SCARIFIED AT LEAST 4 INCHES WITH SOME INCORPORATION OF THE UPPER MATERIAL TO AVOID STRATIFIED LAYERS, WHERE FEASIBLE. 2. MULCH PLANTING BEDS WITH 2 INCHES OF ORGANIC MATERIAL 3. USE COMPOST AND OTHER MATERIALS THAT MEET THESE ORGANIC CONTENT REQUIREMENTS: 3.a. THE ORGANIC CONTENT FOR "PRE -APPROVED" AMENDMENT RATES CAN BE MET ONLY USING COMPOST MEETING THE COMPOST SPECIFICATION FOR BIORETENTION (REFER TO SECTION C.2.6) WITH THE EXCEPTION THAT THE COMPOST MAY HAVE UP TO 35% BIOSOLIDS OR MANURE. THE COMPOST MUST ALSO HAVE AN ORGANIC MATTER CONTENT OF 40% TO 65%, AND A CARBON TO NITROGEN RATIO BELOW 25:1. THE CARBON TO NITROGEN RATIO MAY BE AS HIGH AS 35:1 FOR PLANTINGS COMPOSED ENTIRELY OF PLANTS NATIVE TO THE PUGET SOUND LOWLANDS REGION. 3.b. CALCULATED AMENDMENT RATES MAY BE MET THROUGH USE OF COMPOSTED MATERIAL MEETING "A)" ABOVE; OR OTHER ORGANIC MATERIALS AMENDED TO MEET THE CARBON TO NITROGEN RATIO REQUIREMENTS, AND NOT EXCEEDING THE LIMITS IDENTIFIED IN TABLE 220-B, TESTING PARAMETERS, IN WAC 173-350-220. 4. THE RESULTING SOIL SHOULD BE CONDUCIVE TO THE TYPE OF VEGETATION TO BE ESTABLISHED. • IMPLEMENTATION OPTIONS: THE SOIL QUALITY DESIGN GUIDELINES LISTED ABOVE CAN BE MET BY USING ONE OF THE METHODS LISTED BELOW: 1. LEAVE UNDISTURBED NATIVE VEGETATION AND SOIL, AND PROTECT FROM COMPACTION DURING CONSTRUCTION. 2. AMEND EXISTING SITE TOPSOIL OR SUBSOIL EITHER AT DEFAULT "PRE -APPROVED" RATES, OR AT CUSTOM CALCULATED RATES BASED ON TESTS OF THE SOIL AND AMENDMENT. 3. STOCKPILE EXISTING TOPSOIL DURING GRADING, AND REPLACE IT PRIOR TO PLANTING. 4. STOCKPILED TOPSOIL MUST ALSO BE AMENDED IF NEEDED TO MEET THE ORGANIC MATTER OR DEPTH REQUIREMENTS, EITHER AT A DEFAULT "PRE -APPROVED" RATE OR AT A CUSTOM CALCULATED RATE. 5. IMPORT TOPSOIL MIX OF SUFFICIENT ORGANIC CONTENT AND DEPTH TO MEET THE REQUIREMENTS. MORE THAN ONE METHOD MAY BE USED ON DIFFERENT PORTIONS OF THE SAME SITE. SOIL THAT ALREADY MEETS THE DEPTH AND ORGANIC MATTER QUALITY STANDARDS, AND IS NOT COMPACTED DOES NOT NEED TO BE AMENDED. 0 a- rn Know what's below. Call before you dig. T . kr 0-G 16� 46972sv� 0.4 ��GISTV �SSIONAL E��1 07/21 /2025 T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 6" 6" CURB 7 F_ BERM 3' MIN. BIORETENTION CELL NOT TO SCALE REFER TO PLANS FOR PAVEMENT SECTIONS oQ . CLASS 4000 CEMENT CONCRETE 6" COMPACTED SUBGRADE 95% MINIMUM PROCTOR PER PLAN HEIGHT WILL BE 2" - REFER TO PLANS FOR ELEVATION 2.00' 1.00, a ° d a D0. O11 8" 4" CRUSED SURFACING TOP COURSE CONCRETE VALLEY GUTTER NOT TO SCALE 3' MIN. 4' BERM 1.5' RETAINING WALL FOOTING 6" BELOW GRADE AT DOCKS. REFER TO STRUCTURAL. ROOF DOWNSPOUT SEE ARCHITECTURAL DETAILS. 6" PVC CAP CUT HOLE TO ALLOW DOWNSPOUT TO PENETRATE WITH 1/8" CLEARANCE. 6" PVC SDR 35 TYP. 2" MIN FINISHED GRADE --\ 4" - COORDINATE DOWNSPOUT LOCATIONS WITH ARCHITECTURAL PLANS AND NOTCH FOOTINGS TO ACCOMMODATE ROOF DRAINS. SURFACE SEAL: NATIVE SOIL OR OTHER LOW PERMEABILITY MATERIAL. 4" PERFORATED RIGID DRAIN PIPE REQUIRED AT LANDSCAPE AREAS (SURROUND WITH 1" ROCK) 2" (MIN.) CONNECT TO 0.5% DETENTION SYSTEM MIN. - -III 12" MIN._ 18" (MIN.)I I I I ICI n BUILDING FOUNDATION J SEE STRUCTURAL DETAILS PROVIDE FITTINGS NOTES: AS REQUIRED DO NOT TIE ROOF DOWNSPOUTS TO FOOTING DRAIN. SURFACE SEAL TO CONSIST OF 12" OF LESS PERMEABLE, SUTIABLE SOIL. SLOPE AWAY FROM BUILDING. ROOF DOWNSPOUT AND FOOTING DRAIN NOT TO SCALE R-433516 r\ N co CO O O Nt N , u N O O O O 4 N V% N O O O i N Q J LO C'O It I 1 LU DocuSign Envelope ID: A9707D3B-AOEF-441F-8140-2CDB48E878CA DESIGNER TO SPECIFY WATER STORAGE ELEVATION FOR EDGE TREATMENT OPTIONS, OVERFLOW STRUCTURE PER STD. PLAN SEE STD. PLAN 262.20 262.40 UNLESS SPECIFIED OTHERWISE BOTTOM WIDTH SIDEWALK, LANDSCAPING, MIN. 18" [SEE STD. DRIVEWAY, OR PAVEMENT PLAN I SIDE SLOPE AT TREE, SEE NOTE 7 262.20 TOP OF BANK SEE STD. ELEVATION74X ..-- �- 6" MIN. ROADWAY OR 2% 2"-12" PONDING FREEBOARD PLAN 262.20 DEPTH PARKING LOT r --1 1=1 I1=1 1=1I 1=1 f -.T- 1�5 . / 1=111=111=1 I1 _1 TRANSITION ZONE SOIL, \j/�'� �� 2.5 MIN; _ _ : , -,� 2.5 MIN SEE STD. PLAN 262.20 2"-4" DEPTH ARBORIST WOOD CHIP MULCH, _ _ _,• �- - -; r`'- - _18" MIN N. SEE NOTE 4 - - - - ANGLE OF REPOSE BIORETENTION SOIL MIX (BSM), OVERFLOW TO STORM MAIN SEE NOTE 3 0 0 0 0 12" MIN. ABOVE SCARIFIED AND UNCOMPACTED SUBGRADE, SEASONAL HIGH _ SEE NOTES 1 AND 2 GROUNDWATER OR HYDRAULICALLY RESTRICTIVE LAYER GRAVEL BASE, SEE STD. PLAN 262.40 1. AVOID COMPACTION OF EXISTING SUBGRADE BELOW BASIN. 2. SCARIFY SUBGRADE TO A DEPTH OF 3 INCHES MINIMUM IMMEDIATELY PRIOR TO PLACEMENT OF BIORETENTION SOIL MIX (BSM) AND UNDERDRAIN AGGREGATE. 3. 18" MIN. BIORETENTION SOIL MIX ON BOTTOM AND SIDES TO TOP OF PONDING AREA. BIORETENTION SOIL MIX TO MEET STD. PLAN 262.60. 4. ARBORIST WOOD CHIP MULCH TO MEET STD. PLAN 262.60. 5. DO NOT USE FILTER FABRIC BETWEEN SUBGRADE AND THE BIORETENTION SOIL MIX. 6. MAXIMUM LONGITUDINAL SLOPE (ALONG DIRECTION OF FLOW) OF BIORETENTION SWALES SHALL BE 6%. 7. WHERE NOT CONFLICTING WITH REQUIRED CLEARANCES OR UTILITIES, TREES MAY BE LOCATED IN BIORETENTION. REDUCE BOTTOM WIDTH TO 6 INCHES MINIMUM AND INCREASE SIDE SLOPE TO 1.5H:1V ADJACENT TO TREE. TREES TO BE LOCATED ONLY OUTSIDE OF LINER FOR LINED FACILITIES. GENERAL NOTES: 1. MINIMUM UTILITY SETBACKS AND PROTECTION MEASURES MUST CONFORM TO CURRENT CITY STANDARDS, STD. PLANS 265.00, 265.10, AND 265.20, AND OTHER UTILITY PROVIDER REQUIREMENTS. COORDINATE WITH CITY ENGINEER IN THE EVENT OF UTILITY CROSSINGS OR CONFLICTS. 2. BSM PLACEMENT, GRADING, AND CONSOLIDATION SHALL NOT OCCUR WHEN THE BSM IS EXCESSIVELY WET OR HAS BEEN SUBJECTED TO MORE THAN 1/2" OF PRECIPITATION WITHIN 48 HOURS PRIOR TO PLACEMENT. EXCESSIVELY WET IS DEFINED AS BEING AT OR ABOVE 22% SOIL MOISTURE BY A GENERAL TOOLS AND INSTRUMENTS DSMM500 PRECISION DIGITAL SOIL MOISTURE METER WITH PROBE (OR EQUIVALENT). THERE SHOULD BE NO VISIBLE FREE WATER IN THE MATERIAL. THE CONTRACTOR SHALL PLACE BSM LOOSELY WITH A CONVEYOR BELT OR WITH AN EXCAVATOR OR LOADER FROM A HEIGHT NO HIGHER THAN 6 FEET, UNLESS OTHERWISE APPROVED BY THE ENGINEER (I.E., DO NOT DUMP MATERIAL DIRECTLY FROM TRUCK INTO CELL). COMPACT BSM USING NON -MECHANICAL COMPACTION METHODS (E.G., BOOT PACKING, HAND TAMPING, OR WATER CONSOLIDATION) TO 83 % (± 2%) OF THE MAXIMUM DRY DENSITY PER MODIFIED PROCTOR TEST (ASTM D1557), OR AS DIRECTED BY THE ENGINEER. 3. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 262.00 Alffi=V`R] .PUBLIC WORKS BIORETENTION SECTION APP DEPARTMENT (NO UNDERDRAIN) Martin Pastucha 11/2/2 -8881134FD98B449D... DATE Public Works Administrator BIORETENTION SECTION (NO UNDERDRAIN) 0 v 0 oa � Know what's below. Call before you dig. 20 1 1 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 PLANTING ZONES,- -- _ _ _ _ _ SEE BELOW;L..-, O O O ) O 2"-4" DEPTH ARBORIST I I I I WOOD CHIP MULCH, SEE STD. PLAN 262.60 BOTTOM WIDTH SIDE SLOPE AT MIN. 18" TREE, SEE NOTE 1 ROADWAY SIDEWALK OR LANDSCAPING 2"-12" PONDING _ DEPTH _ o / i` = 1.5 a . TRANSITION ZONE SOIL, !\'\ _,il `-a;/ =`,_ 'x',:, SEE STD. PLAN 262.20 / _ - - 6" MIN.`-�-'y,° MIN';' BIORETENTION SOIL MIX, !\'x SEE STD. PLAN 262.60 _ lr':• SCARIFIED AND UNCOMPACTED SUBGRADE 1. WHERE NOT CONFLICTING WITH REQUIRED CLEARANCES OR UTILITIES, TREES MAY BE LOCATED IN BIORETENTION. REDUCE BOTTOM WIDTH TO 6" MIN. AND INCREASE SIDE SLOPE TO 1.5H:1V ADJACENT TO TREE. TREES TO BE LOCATED ONLY OUTSIDE OF LINER FOR LINED FACILITIES. GENERAL NOTES: 1. ALL PLANTS SHALL BE SELECTED WITH A MAXIMUM MATURE HEIGHT NOT GREATER THAN 30-INCHES ABOVE THE TOP OF THE FACILITY, WITH THE EXCEPTION OF TREES AND ACCENT SHRUBS. 2. SEE STD. PLANS 262.00, 262.10, AND 262.20 FOR SECTION VIEWS OF BIORETENTION FACILITIES. 3. SEE THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) TABLE C.2.6.A FOR A SELECTION OF APPROVED WATER TOLERANT PLANTS. ADDITIONAL SPECIES ARE ALLOWED WITH CITY APPROVAL. 4. SELECT A MINIMUM OF 50 % EVERGREEN PLANTS. 5. PLANTS ADJACENT TO STREET, DRIVEWAY, OR SIDEWALK SHALL BE SELECTED AND SPACED TO ALLOW ACCESS TO VEHICLES AND NOT IMPEDE PEDESTRIANS. 6. PLANTS SHALL BE SPACED TO ENSURE CLEAR ACCESS AND UNIMPEDED FLOW FROM INLETS, OUTLETS, AND OVERFLOWS. 7. CONTINUE MULCH FOR A MINIMUM OF 2-FEET PAST THE TOP OF BANK ELEVATION OR INSTALL LANDSCAPE EDGING IF FACILITY IS ADJACENT TO TURF. 8. PLANTING DESIGN SHOULD MINIMIZE COMPACTION OF BIORETENTION SOIL MIX THROUGH PLANNED MAINTENANCE ACCESS. ANNUAL PLANTS REQUIRING SOIL DISTURBANCE FOR HARVESTING (E.G., CARROTS) OR ANNUAL REPLANTING ARE NOT PERMITTED. 9. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. TABLE: PLANTING ZONES ZONE PLANT TYPE LOCATION EMERGENTS, PERENNIALS & LOW SHRUBS (PLANTS O THAT CAN TOLERATE STANDING WATER) FACILITY BOTTOM PERENNIALS & LOW SHRUBS (PLANTS OEMERGENTS, 2 THAT CAN TOLERATE OCCASIONAL STANDING LOWER SLOPE TO TOP OF PONDING WATER) OGROUNDCOVERS / SHRUBS UPPER SLOPE / SIDEWALK GRADE O O O ACCENT SHRUBLAPPROPRIATE SHRUB SIDEWALK GRADE / LOWER SLOPE / FACILITY BOTTOM BASEDON ZONE OTREE UPPER SLOPE, SEE NOTE 1 UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 262.50 fiRl PUBLIC WORKS BIORETENTION PLANTING - APPR E° DEPARTMENT SECTION VIEW GAZ 9/28/2018 P,brc W,,k:Admmi,t,, r DATE BIORETENTION PLANTING - SECTION VIEW *$ *UNLESS OTHERWISE NOTED ON PLANS 0000000 000000 00 ODODOD0 0 0 ODOR O O O O O O C:) 0 0 0 0 0 0 0 0 0 0 0 INLET/OUTFALL PIPE O O O O O o 0000000000000000 EXISTING AND/OR PROPOSED GROUND OUO U n n 4" MIN. FACE QUARRY ROCK \-12" MIN. DEPTH (12"0 PIPE) 18" MIN. DEPTH (15"-18" O PIPE) 24" MIN. (24"-36" O PIPE) SECTION INLET PROTECTION (AT BIORETENTION) NOT TO SCALE I'd 46972sv� �.� �ECISTY19k �SSIONAL E��l 07/21 /2025 T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB :45 AN 2"0 PVC PIPE DRIVEN INTO GROUND PRIOR TO ROCK PLACEMENT TO ENSURE PLANTING SPACE FOR WILLOW STAKES. PIPES SPACED 1.5' ON CENTER. REFER TO ECOLOGIST SPECIFICATIONS. *8 * UNLESS OTHERWISE NOTED ON PLANS 0®0S000000 0000 00<5060b0?000 0000 000 Q O® O 6) O 6) O 0. INLET/OUTFALL PIPE O O O O O 0�0®0®O®0®OD0 0 0 PLAN EXISTING AND/OR -�p1PE PROPOSED GROUND O O C- O OUO UO 00 n n 12" MIN. DEPTH (12"0 PIPE) 4" DIA. 18" MIN. DEPTH (15"-18" O PIPE) ROUNDED ROCK 24" MIN. (24"-36" O PIPE) DocuSign Envelope ID: 3131 B34D3-7EOA-476C-ADB3-4329FFEOC108 BIORETENTION SOIL MIX BIORETENTION SOIL MIX (BSM) SHALL BE A WELL -BLENDED HOMOGENEOUS MIXTURE OF 60 TO 65 PERCENT BY VOLUME MINERAL AGGREGATE FOR BIORETENTION SOIL AND 35 TO 40 PERCENT BY VOLUME COMPOST AS DETAILED IN THE TABLES BELOW. MINERAL AGGREGATE FOR BIORETENTION SOIL TABLE: MINERAL AGGREGATE GRADATION SIEVE SIZE PERCENT PASSING 3/8-INCH 100 PERCENT U.S. NO. 4 95 TO 100 PERCENT U.S. NO. 10 75 TO 90 PERCENT U.S. NO. 40 25 TO 40 PERCENT U.S. NO. 100 4 TO 10 PERCENT U.S. NO. 200 2 TO 4 PERCENT TABLE: COMPOST GRADATION SIEVE SIZE MIN. PERCENT PASSING 2-INCH 100 PERCENT 1-INCH 99 PERCENT 5/8-INCH 90 PERCENT 1/4-INCH 75 PERCENT MINERAL AGGREGATE FOR BIORETENTION SOIL MUST BE FREE OF WOOD, WASTE, COATING, OR ANY OTHER DELETERIOUS MATERIAL, AND ALL AGGREGATE PASSING THE NO. 200 SIEVE SIZE MUST BE NON -PLASTIC. MINERAL AGGREGATE MUST BE ANALYZED BY AN ACCREDITED LAB USING THE SIEVE SIZES NOTED IN THE TABLE TO THE LEFT, AND MUST MEET THE REQUIRED GRADATIONS. COMPOST MUST ORIGINATE A MINIMUM 65 PERCENT BY VOLUME FROM RECYCLED PLANT WASTE COMPRISED OF YARD DEBRIS, CROP RESIDUES, AND BULKING AGENTS, AND MEET THE DEFINITION OF "COMPOSTED MATERIAL" IN WAC 173-350-100. COMPOST SHALL HAVE A MOISTURE CONTENT THAT HAS NO VISIBLE FREE WATER OR DUST PRODUCED WHEN HANDLING THE MATERIAL. COMPOST SHALL HAVE AN ORGANIC MATTER CONTENT OF 40 PERCENT TO 65 PERCENT BY DRY WEIGHT, A CARBON TO NITROGEN RATIO BELOW 25:1, AND A pH BETWEEN 6.0 AND 8.0 ABORIST WOOD CHIP MULCH TABLE: ARBORIST WOOD CHIP MULCH GRADATION SIEVE SIZE PERCENT PASSING 6-INCH 100 PERCENT 2-INCH 95 TO 100 PERCENT 1-INCH 70 TO 100 PERCENT 5/8-INCH 0 TO 50 PERCENT U.S. NO. 4 0 TO 30 PERCENT ARBORIST WOOD CHIP MULCH SHALL BE COARSE GROUND WOOD CHIPS (APPROXIMATELY 1/2" TO 6" ALONG THE LONGEST DIMENSION) DERIVED FROM THE MECHANICAL GRINDING OR SHREDDING OF THE ABOVE -GROUND PORTIONS OF TREES. IT MAY CONTAIN WOOD, WOOD FIBER, BARK, BRANCHES, AND LEAVES, BUT MAY NOT CONTAIN WEEDS, WEED SEEDS, OR VISIBLE AMOUNTS OF SOIL. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 262.60 V'RI • PUBLIC WORKS BIORETENTION SOIL MIX, COMPOST,1T@&W1F9@@B44@rD_ 6&Rdby: DEPARTMENT AND MULCH SPECIFICATIONS artin Pastucha 8/13/20 artin Pa,[ ha DATE BIORETENTION SOIL MIX & COMPOST & MULCH SPECIFICATIONS SECTION OUTFACE PROTECTION (AT CREEK) NOT TO SCALE MIL. R-433517 A Li CD C) C) C) N r 0- DROP -IN METER BY CITY FORCES. DROP -IN METER PERMIT REQUIRED EXISTING DOMESTIC - SERVICE LINE TO BE CUT AND CAPPED STA:1 +03.46, 0.00' AT MAIN BY CITY FORCES. CUT AND CAP 1-12"x10" TEE (MJxFL) PERMIT REQUIRED 1-10" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK WET TAP WILL BE IN ACCORDANCE WITH COR STD PLAN 300 6 1 ' SEE STANDARD PLAN 300.5 ON SHEET C5.1 .% / R C5.4 FOR CONNECTION DETAIL. 1�23. EXISTING FIRE HYDRANT \ STA:1 +82.04, 6.50' LT GJ / �( 1" IRRIGATION SERVICE CONNECTION /� P( �NC,12 \ PER COR STD PLAN 320.1 DROP -IN METER BY CITY FORCES. DROP -IN METER PERMIT / / ANITARY SEWER REQUIRED / MANHOLE I M 400.4 12" CONC NE IE 8" PVC 8. I /12" CO W 388 / B® °a / / S :1 +94.9 .16 LT 2 1-FIRE DEP MENT NNECTION FOUND INVERTED NAIL IN ST • 3.96, 0.00' / d ONCRETE POST, INCASED �E 1- 2.50 BEND (MJ S el ° i 1-CONC. THRUST B STA:2+10.34, 6.50' LT 1" WATER SERVICE CONNECTION 0 (BY CITY F(1R(F PER COR STD PLAN 323y�F T + 34, 0.00' 1-10"x "TEE (MJxFL) ° / FOUND INVERTED NAIL IN CONCRETE POST, INCASED / SANITARY SEWER MANHOLE RIM 400.93 8" CONC N 391.53 IE 1" DCVA FOR 12" CONC NE 390.88 IE IRRIGATION �-' / O cP, 6" CONC S 391.82 IE 12" CONC SW 390.90 IE S � JANIT SEWER MANHOLE RI 0.71 / p " CONC NE 388.8_1 FR 12" QE)NC 5W388.61 I GRAVEL- / i 6.50' ROW DEDICATION 6 �� I PROPOSED COMMERCIAL BUILDING i / PRPOSED MEDICAL /'OFFICE SHELL / 6,200 SF FOOTPRINT • FF: 399.50 1" WATER SER\/ACE AND RPBA BACKFLOW I a2 DEVICE SHAD BE PROVIDED INSIDE THE z ° BUILDING PAR COR STD DETAIL 350.2 LS / VA FIR BACKFLOW ASSEMBLY SHALL BE INSTALLED INSIDE THE BUILDING PER COR STD 0TA:2+13.34, 6.49 LT 1-PIV VALVE PER COR STD DTL 360.5 1-6 GATE VALVE (FLxMJ) :2/,T&34, 7.50' LT 1-CONC. THRUST BLOCK ER\FIRE HYDRANT ASSEM MANHOLE SANITARY SEWER FH ASSEMBLY PER COR ° ,4'X4' CON PAD PER RIM 398.25 STD PLAN 310.1, 310.2, 310.3 COR STD DTL 310.2 12" CONC NE 386.00 IE STA:2+21.28, 0.00' \ / \ 12" CONC SW 385.95 IE 1-10" POLYPIG STATION i PER COR STD PLAN 300.7 DETAIL 360.5. FIRE SERVICE LINES TO BE 4" DI CL 52. REFER TO FIRE PROTECTION NOTE ON SHEET C5.7 LO co M U) 2 SSCO #2 RIM:399.33 / IE: 393.80 8" (SW) LO IN / IE: 393.80 8" (SE) 1 I 36 LF 8" PVC @ 2.00% •� � II SSCO #1 RIM: 398.26 IE: 394.51 8" (NW) INSTALL SEWER SERVICE` 1-1 IE: 390.39 8" (E) CO # 5 LF 8" 8% RIM:399.41 GIA ENTERPRISES 6 LF 8" PVC @ 4.36% IE: 392.42 8" (NW) 0323059097 9j 35 LF 8" SSCO #6 IE: 392.42 8" (NE) / C0 RIM: 398.23 IN PVC @ 3.5 ° 8' /0 398 A IE: 390.65 8" (W) 4"FIR .:: � \ Q IE: 390.65 8" (E) � R91 I 9 3 � < 20' SEWER EASEMEN 16"FI "� 1.9 ) E: 8" SE) < WORKMAN ARLENE M. \ i 0323059055 .0"FI 16"FIRS Ix W W W I W _ / 3g6 I I 9 , I 30IR 24" FIRM / / 40 .00' STREAM �I BUFFS / �' V`tF 8 14"FIR l � \ . . . =� SANITARY SEWER MANHOLE - RIM 396.32 8" PVC S 393.35 IE 8" PVC SE 393.38 IE 8" PVC N 393.27 IE 164.55 N890 37; 58 W 16"FI 0" Fir /BECK HOLDINGS LLC 30 -393' % j / i ii 0323059044 F /� I f /-392- O pF WASgj���O�l 0 Q Q�� TACOMA • SEATTLE rl ;P 46972 wSPOKANE TRI-CITIES �,srsTER�O 2215 North 30th Street, Suite 300 Tacoma, WA 98403 Know what's below. SIGNAL E� 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Call before you diq. 07/21/2025 ° 2- ROCKERY SURVEYED: DESIGNED: QF DRAWN: QF 1 PLANS REVISED PER COR 1ST REVIEW COMMENTS QF 2/21/25 CHECKED: SK NO. REVISION BY DATE APPR APPROVED: SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY STREAM BUFFER EDGE OF STREAM STREAM BUFFER NCHMARK DA*C71TY CAL DATUM = NORTH AMERICAN VERTICAL M NAVD 88 (CITY OF RENTON) F RENTON SURVEY CONTROL POINT 2189 405 EXISTING ROAD CENTERLINE Ew STA: 1 +03.46 1-12"x10" TEE (MJxFL) 1-10" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK WET TAP WILL BE IN ACCORDANCE WITH COR STD PLAN 300.6. SEE STANDARD PLAN 300.5 ON SHEET C5.4 FOR CONNECTION DETAIL. 395 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY ELEVATION: 400.60' SITE NO.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH END OF 6' CYCLONE FENCE. ELEVATION: 396.77 PROPOSED ROW I BOUNDARY EXIST G ROW BOUNDARY PROPOSED GRADE AT SEC TION LINE \ EXISTING GRADE AT J SECTION LINE STA: 1 +55.75 EXISTING 12" STORM MAIN W.- -I IE:395.82 c�s2 T 1I 1 1 1.50' 1.50' i i 1 N GRAPHIC SCALE N 0 10 20 40 CY) O 1" = 20 FEET O N U LO 405 O O IN AREAS OF FILL, NEW ROADWAY SUBGRADE SHALL BE FILLED AND COMPACTED BEFORE EXCAVATION (V FOR INSTALLATION OF NEW WATER MAIN (TYP) 400 00 O T N - O O C) _ N STA: 1 +90.03 Q PROPOSED 6" ST RM _ J 395 STA: 2+21.28 1-10" POLYPIG STATION PER COR STD PLAN 300.7 1-22. ° BEND (MJ) / 1-CONC. TH UST BLOCK 22 LF 8" J STA: 2+16.34 5 LF 8" TA: 1+47.62 1-10' 6" TEE (MJxFL) 390 EXISTING 12" EWER MAIN 1- AT VALVE FLxM D.I. CL52 390 T.O.P: 389.29 1-CONC. HRUST BLOCK \ I FH ASS MBLY PER COR EX STING GRADE PROPOSED GRADE 387 AT SECTION LINE AT SECTION LINE 7 r7 �, 0 o cfl 00 o rno ao7 06Iq r10 o 0)0 WWCD 00 00 CDM M �`� M W W LL W LL WILL W LL 1+00 1+50 2+00 2+31.28 10 SITE SECTION 4 SCALE: H:1 "=20', V:1 "=2' W-433501 S-433501 R-433518 IN COMPLIANCE WITH CITY OF RENTON STANDARDS R DEVELOPMENT ENGINEERING ` • LHuynh 07/21/2025 '� WATER UTILITY WASTEWATER UTILITY U;%RW ABDOUL GAFOUR 07/25/2025 `� jstowell 07/28/2025 VERTICAL: NAVD 1988• SUNSET MEDICAL D I CAL OFFICE BUILDING DATE: FOR HORIZONTAL: NAD 1983/183/1991 CITY OF CONSTRUCTION FIELDBOOK: RENTON PAGE: ;R AHBL JOB #2230621.10 DATUM • DRAWING NO: Planning/Building/Public Works Dept. UTILITY PLAN C5.1 SHEET: 18 OF: 34 LO C') It i 0 w FOUND INVERTED NAIL IN CONCRETE POST, INCASED U0 v 0 oa � Know what's below. Call before you dig. i i N2 EEL STOP (TYP.) CONCRETE VALLEY GUTTER PERVIOUS CONCRETE OR PERVIOUS PAVING WORKMAN ARLENE M. 0323059055 20' SEWER EASEMENT 1671 �+ T. xrJ CVO -F WASgIN� < ��.� kEClSTEg�9 ASV �SSIONAL E��l 07/21 /2025 k\ O G� V / 6 N � c IVAi a ' W F 164.55' N89° 37' 58"W, WF AA61� W F A31 , T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB W F AA51 BECK HOLDINGS LLC 0323059044 / FOU CON / PROPOSED COMMERCIAL BUILDING PERVIOUS CONCRETE OR PERVIOUS PAVING REFER TO ARCHITECTURAL PLANS FOR TRASH ENCLOSURE GIA ENTERPRISES 0323059097 I GRAPHIC SCALE 0 10 20 40 1" = 20 FEET ACCESSIBLE PARKING NOT TO SCALE PAVING PLAN LEGEND EC EXTRUDED CURB 5 C6.2 VC VERTICAL CURB 1 C6.2 a VCO 12" VERTICAL CURB OPENING FC FLUSH CURB 6 C6.2 NC NO CURB O CHANGE CURB TYPE/END CURB ASPHALT CONCRETE PAVEMENT 2 u C6.2 CONCRETE SIDEWALK 2 C3.2 PERVIOUS CONCRETE 10 C6.2 MAINTENANCE ACCESS ROAD. ALTERNATIVE 7 SURFACE. GRASS PAVE OR SIMILAR. C6.2 N GRAPHIC SCALE 0 5 10 1"=5FEET 8 :6.2 R-433519 N co co N AM u III') O O O 4 oc n 00 T N O O O N Q D J 5 1/2" 1" R FINISH GROUND GRADE PAVEMENT - N '' =III_,, III ;III ;III Q. d NOTE a a IT CONSTRUCTION SHALL CONFORM TO WSDOT SPEC. 8-04.3 a a a 7 3/4" VERTICAL CURB NOT TO SCALE 50 CM (19.7") 16.7 CM (6.6") 25 CM (9.8") ENLARGEMENT SPECIFICATIONS UNIT SIZE - 50 CM X 50 CM X 2.5 CM OR 1 M X 1 M X 2.5 CM (20" X 20" X 1 " OR 40" X 40" X I") AVAILABLE IN 9 STANDARD ROLL SIZES JNIT WEIGHT - 510 GRAMS (18 OZ.) OR 2.0 KG (4.5 POUNDS) ;TRENGTH - 1121 KG/C;M (15,940 PSI) �OLOR - BLACK RESIN - 100% RECYCLED HDPE PLAN GRASSPAVE2 SQUARES ADJACENT GRASSPAVE2 UNITS SEE ENLARGEMENT BELOW HYDROGROW MIX BELOW RING SUPPLIED FREE BY MANUFACTURER HMA CLASS 1/2" PER WSDOT 9-03.8(1) 3" 6'0 0 0 -CRUSHED SURFACING BASE COURSE PER WSDOT 9.03-9(3) 12" COMPACTED NOTES: SUBGRADE TO 95% 1. ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. 2. THE CONTRACTOR SHALL EXPOSE EXISTING SUBGRADE, PROOF ROLL AND COMPACT TO 95%. IF YIELDING CONDITIONS ARE ENCOUNTERED, YIELDING MATERIALS SHALL BE REPLACED WITH IMPORTED STRUCTURAL FILL MATERIAL. THE DEPTH OF MATERIAL REPLACEMENT SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER. PAVEMENT SECTION NOT TO SCALE 10" 6" BOTTOM OF CEMENT CONCRETE CUT/SAWED JOINT o 2.5" 5" L. 2.5" CURB, WSDOT SPEC. 15' INTERVAL 8-04 ��°° III=� III =1-- O° O� 0000° I' O � O0 k O�° O°O O o° � °° O ° SEE LANDSCAPE PLAN o �° �0° o FOR FILL BEHIND CURBS ° EXTRUDED CURB :5: NOT TO SCALE RINGS FILLED WITH CONCRETE SAND (CLEAN, SHARP SAND) -COMPACTED SANDY GRAVEL ROAD BASE s" 95% MODIFIED PROCTOR DENSITY -SEE FULL TECHNICAL SPECIFICATIONS FOR COMPOSITION COMPACTED SUBGRADE, SECTION TOP F GRASS ROOT MASS 6 MM (1 4") ABOVE TOP OF RING GRASSPAVE2 ATTACH WITH SNAP -FIT FASTENERS ;INGS FILLED WITH CONCRETE SAND (CLEAN, SHARP SAND) OMPACTED SANDY GRAVEL BASE COURSE -SEE FULL TECHNICAL SPECIFICATIONS FOR COMPOSITION NOTE: GRASS MIX SHALL BE DEEP ROOTING AND HARDY SPECIES FOR REGION. PROVIDE RYE OR FESCUE LAWN MIX. TYPICAL GRASSPAVE2 DETAIL CHOOSE THIS PRODUCT FOR REINFORCING GRASS WEARING SURFACES NOT TO SCALE 16265 E. 33RD DR., SUITE 20 AURORA, COLORADO 80011 800-233-1510 OR 303-233-8383 FAX: 800-233-1522 OR 303-233-8282 www.invisiblestructures.com GRASSPAVE Invisible Structures, Inc. rev. 1/18 GPDET18.DWG NOT TO SCALE 0 a� Know what's below. Call before you dig. T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S ���.5kEClSTER�9 �� �SSIONAL E2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 07/21 /2025 CC 12" NOTES: 1. ALTERNATIVE - SIGN MAY BE SECURELY MOUNTED TO BUILDING WALL. ADA PARKING SIGN NOT TO SCALE 1/4" EDGED GROOVE 0.02 FT/FT 1.4 a a a a a a a a . a 4" CEMENT CONCRETE SIDEWALK 2" CRUSHED SURFACING TOP COURSE PER PLAN q RAMP DETECTABLE WARNING PATTERN AREA COMPACTED SUBGRADE B SHALL BE YELLOW, IN COMPLIANCE WITH WSDOT STANDARD SPEC. 8-14.3(3) O O 0 NOTES: 1. CEMENT CONCRETE SHALL BE CLASS B. 2. COMPACTION FOR CONCRETE WALKS TO BE 95% MAXIMUM DENSITY. 3. EXPANSION JOINTS CONSISTING OF 3/8" BY 4" PREMOLDED JOINT MATERIAL SHALL BE PLACED AT 15 FOOT INTERVALS, OR AS DIRECTED BY THE ARCHITECTURAL PLANS. 1/4" EDGE GROOVE SHALL BE PROVIDED AT JOINT EDGES. 4. SEE ARCHITECTURAL PLANS FOR JOINT PATTERNS. ONSITE CONCRETE SIDEWALK NOT TO SCALE PAVEMENT 6" FINISH GRADE AT SIDEWALKS ' a a.. a a , 4 a. iv NOTE CONSTRUCTION SHALL CONFORM TO WSDOT a SPECIFICATION 8-04.3. FLUSH CURB NOT TO SCALE L #3 BARS (2) ELEVATION 13/16" DIA. HOLES r%0 A \. 2" CLR (TYP) 5" 2 1/2" � 2 1/2" 6„ #3 BARS (2) 101, NOTES: NON -SHRINK 1. THE NON -SHRINK GROUT USED TO GROUT ATTACH THE PRECAST CURB SHALL CONSIST OF 3:1 SAND AND CEMENT. GROUT TO A DEPTH OF 1" FROM THE TOP OF THE BUMPER. #6 BAR (2) 18" MIN 2. LOCATIONS FOR WEEPHOLES, AND V-SLOTS SHALL BE IDENTIFIED ON ( THE DELIVERY ORDER DRAWINGS. Id 3. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 ATTACHMENT DETAIL PSI AT 28 DAYS. WHEEL STOP NOT TO SCALE CD M MIN MAX A 1 5/8" 2 3/8" B 5/8" 1 1/2" C 7/1 6" 3/4" D 7/8" DETECTABLE WARNING STRIP NOT TO SCALE o 0 0 0 0 0 0 0 0 0 0 o PERMEABLE CONCRETE SECTION 0 0 0 0 0 0 0 0 0 0 0 0 O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 U 8" D O O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 AGGREGATE STORAGE RESERVOIR COURSE 12" INFILTRATING FILL VARIES r FIRM AND UNYIELDING /// ///\//\//\//\//\ SUBGRADE PERVIOUS CONCRETE NOTES: 1. A UNIQUE IDENTIFICATION NUMBER FOR THE MIX DESIGN THAT IS APPROVED FOR THE JOB MIX FORMULA (JMF). 2. PORTLAND CEMENT SHALL BE TYPE I, TYPE II, TYPE HI, TYPE IP, OR TYPE IS. 3. CEMENTITIOUS CONTENT: 480 POUNDS PER CUBIC YARD. 4. MIX TO INCORPORATE A HYDRATION STABILIZING ADMIXTURE 5. SYNTHETIC MICROFIBERS MAY BE UTILIZED AT THE MANUFACTURER'S RECOMMENDED DOSAGE RATE. 6. WATER/ CEMENT RATIO SHALL NOT EXCEED 0.35. 7. NO MORE THAN 25 PERCENT OF PORTLAND CEMENT IN THE MIX, BY WEIGHT, MAY BE REPLACED BY FLY ASH, GROUND GRANULATED BLAST FURNACE SLAG, OR A COMBINATION OF BOTH. 8. COARSE AGGREGATE SHALL CONFORM TO SECTION 9-03.1 (4), AASHTO GRADING NO. 8. NOTES: 1. ALL DEPTHS SHOWN ARE COMPACTED DEPTHS. 2. THE CONTRACTOR SHALL EXPOSE EXISTING SUB -GRADE, PROOF ROLL AND COMPACT TO 90-92%. IF YIELDING CONDITIONS ARE ENCOUNTERED, YIELDING MATERIALS SHALL BE REPLACED WITH IMPORTED STRUCTURAL FILL MATERIAL. THE DEPTH OF MATERIAL REPLACEMENT SHALL BE DETERMINED BY THE GEOTECHNICAL ENGINEER. 3. INFILTRATING FILL BENEATH PERMEABLE CONCRETE SECTION TO PROVIDE INFILTRATION RATES MEETING OR EXCEEDING THE EXISTING UNDERLYING SOILS. FILL MATERIAL TO BE APPROVED BY GROTECHNICAL ENGINEER. INFILTRATION TESTING NOTE PRIOR TO BACKFILL OF INFILTRATING FILL OR PERMEABLE SURFACES, CONTRACTOR SHALL COORDINATE AND RECEIVE WRITTEN GEOTECHNICAL ENGINEER APPROVAL TO BACKFILL MATERIALS. GEOTECHNICAL ENGINEER TO PROVIDE CONFIRMATION OF ACCEPTABLE SUB -GRADE FOR INFILTRATION AND PROVIDE INFILTRATION TESTING AS NEEDED. INFILTRATION VERIFICATION REPORT SHALL BE PROVIDED TO ENGINEER AND CITY INSPECTOR. TESTING SHALL BE IN ACCORDANCE WITH REFERENCE 6-A OF THE 2021 KING COUNTY SURFACE WATER DESIGN MANUAL. FINAL VERIFICATION OF PERFORMANCE TO BE CONDUCTED BY GEOTECHNICAL ENGINEER. THE CITY MUST BE NOTIFIED OF THE SCHEDULED INFILTRATION TESTING AT LEAST 2 WORKING DAYS IN ADVANCE OF THE TEST. PERMEABLE CONCRETE SECTION NOT TO SCALE R-433520 N (fl O Nt N , U N LO O O It N Ir N O O O N Q J / FOUND INVERTED NAIL IN CONCRETE POST, INCASED S / / MANIHORE SEWER RIM 400.93 o 8" CONC N 391.53 IE 12" CONC NE 390.88 IE 6" CONC S 391.82 IE 12" CONC SW 390.90 IE V� / .0/ / CATCH BASIN / ,` _`S�i RIM 400.78 V� 12" CONC SW 397.38 IE 45 B> �1 / JANIT SEWER -MANHOLE S / L ° a / a RI 0.71 CONC-NE 388.80 IE CATCH BASIN `S\) 12" CMC SW 388.61 I S RIMCONC SW 397.30 IE / / \ / � 23?1 CATCH BASIN \ \ S AL.�07C / i ° GRAVEL � / N S R398.80 2MCONC NE 394.86 IE N � 12" CONC N 394.84 IENil 12" CONC SW 394.91 IIE/ / P NG� \ / \ / / �� / / G S/ SANITARY SEWER \\ 595' ,' / / / j ° / / MANk6LE ° S / .RtM 400.4 \ \ / / �/ ' / / 12" COJ� NE 38 IE L� / i, 00, / 1 LS D / /8" PVC 8.911 gP \ S \ �� / ° / / `� _,,I2" CO W 388 E BN / CATC ASI °4 a a M 399.93 / / ° . ° :. ° .: .000, �� FOUND INVERTED NAIL IN 12 C NE 395.33 IE / i a., ,�.. FRENCH DRAIN ONCRETE POST, INCASED 1 " ONC SW 395.2 / / / O 6.50' ROW DEDICATION S / PROPOSED MEDICAL / ° Q a SANITARY SEWE.. MANHOLE RIM 398.25 12" CONC NE 386.00 IE 12" CONC SW 385.95 IE 12"FIR \ WORKMAN ARLENE M. 0323059055 24"FIR \ 20' SEWER EASEMENT 1671 2071 16"FIR .•G•,•'�, I� 24" FIR 14"FIR SANITARY SEWER MANHOLE RIM 396.32 8" PVC S 393.35 IE 8" PVC SE 393.38 IE 8" PVC N 393.27 IE #; f::• : 0" Fir 1671 :1rfi OFFICE SHELL 5,200 SF FOOTPRINT 0- LS 30" FIR / 40.00' STREAM / BUFFER / WF A8 / F A7 W F AA8 WF AA7 WF A6 18" M,4 WF AA6I WF A5 BECK HOL INGS LLC 30"F WF AA51 03230 9044 8" CONCRETE CULVERT WF A3, / 393.56 IE S I O Q T A C O M A S E A T T L E 46972 �� SPOKANE TRI-CITIES �.��6 'GIST Know what's b@IOW. 2215 North 30th Street, Suite 300 Tacoma, WA 98403 AL E� 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEBCall before you dig. 07/21/2025 J Q 2 a- U) Q FRENCH DRAIN DETENTION CHAMBERS U) Q 48" CMP CULVERT 389.11 IE ROCKERY GIA ENTERPRISES 0323059097 N GRAPHIC SCALE 0 10 20 40 1" = 20 FEET UTILITY CROSSING O O O O PROP.6" O PROP.6" PROP. STORM STORM STO 1.5' MIN IE= 396.66 1.5' MIN IE= 396.59 rE=t.42 PROP FIRE WATER PROP 1" WATER PROP 8" SEWER T.O.P= 395.16 T.O.P= 395.09T.O.P= 394.46 0 0 0 O PROP.6" O PROP.6" O PROP.6" STORM STORM STORM 1.5' IE= 396.09 3.43' IE= 395.03 1.54' IE= 395.85 PROERO" PROP 8" SEWER PROP 8" SEWER T.O.P= 394.59 T.O.P= 391.60 T.O.P= 394.31 W-433506 S-433504 R-433521 N co CO O N , u O O I N V% O 0 i N Q J co co It i O 0 W V � I I I I bI WORKMAN ARLENE M. ti 0323059055 12"FIRO w LO �e N O 20' SEWER EASEMENT 1671 GRASS -PAVE OR APPROVED EQUAL _4" FIR 14"FIR Ov 0 oa � Know what's below. Call before you dig. / WWW / WWW / 164.55' N89° 37'58") / S i i i / I 30" FIR 40.00' STREAM BUFFER W F A8 I c� WF A7 WF AA8' W F A_ A7 WF A6 S��NGS� 18" M,4 W F AA6 WF AA51 / WF A31 / TRUCK TURNING - ENTERING SITE �+ T. WAxrj �VO� pg Sk j14 < OA GIST �SSIONAL E��1 07/21 /2025 T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB V BECK HOLDINGS LLC 0323059044 / / / S L yNA -� 1p�2 JO - i�i a ,�• N S AL.PO)C 1 /a � /NOSE LPN GO \ C,V / o .010 / V � I I I I bI WORKMAN ARLENE M. 0323059055 12"FIRO w bJ - 20' SEWER EASEMENT 16"FI 0 24" FIR 14"FIR 0 LIE s ° 13.00 43.00' 20.00' i i W 20. 0' W / / 30" FIR WWW / WWW / WWW / W F A8 c� WWW / W F A7 W F AA8 W F AA7 W W F A6 `s��NG 18" M,4 / 164.55' N89° 37' 58"W. - WF AA61 AV30" Fir WF A5y WF AA51 hk\ WF A31 / TRUCK TURNING - EXITING SITE 'L/ BECK HOLDINGS LLC 0323059044 Il' GRAPHIC SCALE 0 10 20 40 1" = 20 FEET Copy of Rear —Load Garbage Truck Overall Len th Overall Widt� Overall Body He i ht Min Body Ground Clearance Track Width Lock —to —lock time Curb to Curb Turning Radius NOTES: GARBAGE TRUCK FOR ILLUSTRATION PURPOSES ONLY. GARBAGE TRUCKS WILL BE FRONT LOAD. 37.000ft 8.833ft 18.000 ft 1.080ft 8.833ft 6.00s 38.000ft R-433522 U �, LO O O O O N rr 0— KOC N O O N Q D J CY) I I W a / IZ CATCH BASIN RIM400.13 12" CONIC SW 397.30 IE ATCH BASIN \\ / AL PDX � - GRAVEL - RIM 398.80 F / / 12 CONIC NE 394.86 IE 1�� ,2� 6 / : S. ° < 12" CONIC 394.84 1E / T' J 12" CONC SW 394.91 IE/ \ \ / N / S / 4. as � �' / \\595 ,��� �°� O°� a ❑ � `// 'i ell Cn a D >�CAIC AS I N + / M 399.93 / / / / .� ° ° / 12" C NE 395.33 IE + 1 ONC SW 395.2 4 / ^4 . °Q / LS _ a y�F \ 3�3 C a L_ EX. 29" FIR TO BE REMOVED I co 12"FIR :+: + ° + ° 0 24"FIR • 20' SEWER EASEMENT 16"FI 2071 C 16"FIR C TREE PROTECTION FENCING, SEE DETAIL 111.00 EX. 27" FIR TO REMAIN 14"FIR 16"FIE- 30" • 0>1� • FF: 399.50 _MvA•6 III MIAMI <. . • CATCH BASIN RIM 400.78 12" CONIC SW 397.38 IE TREE PROTECTION FENCING, SEE DETAIL 111.00 - EX. 30" FIR TO REMAIN I CRETE CULVERT -�1 I (V A�l �1 �� /� /�/i 393.561E i WFA4 LANDSCAPE NOTES AND SOIL QUALITY 1. LANDSCAPE AREAS SHOULD BE DEEP -TILLED TO A DEPTH OF AT LEAST TWELVE (12) INCHES TO FACILITATE DEEP WATER PENETRATION AND SOIL OXYGENATION. PROVIDE SOIL AMENDMENTS ENCOURAGED TO IMPROVE WATER DRAINAGE, MOISTURE PENETRATION OR WATER -HOLDING CAPACITY. FOR ALL NEWLY LANDSCAPED AREAS ORGANIC MATTER SHOULD BE INCORPORATED TO A DEPTH OF FOUR (4) TO SIX (6) INCHES TO FACILITATE DEEP WATER PENETRATION AND SOIL OXYGENATION. 2. CONTRACTOR SHALL PROVIDE 9" DEPTH IMPORTED TOPSOIL AT ALL LANDSCAPE PLANTING AREAS. Know what's below. Call before you dig. 48" CMP CULVERT 389.11 IE N ROCKERY 3. IMPORTED TOPSOIL SHALL BE 3-WAY MIX. 4. CONTRACTOR SHALL PROVIDE 2" DEPTH FINE COMPOST MULCH THROUGHOUT LANDSCAPE PLANTING AREAS. 5. CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIALS FOR A PERIOD OF (1) ONE YEAR AFTER APPROVAL BY OWNER OR OWNER'S REPRESENTATIVE. 6. TREES PLANTED FIVE FEET OR LESS FROM PAVED SURFACES SHALL BE PLANTED WITH ROOT CONTROL BARRIER. PLANT LEGEND QTY I BOTANICAL NAME COMMON NAME SIZE &SPACING TREES 3 CERCIDIPHYLLUM JAPONICUM KATSURA TREE 1.5" CALIPER, 5' GRAFT 6 STYRAX JAPONICUS JAPANESE SNOWBELL 1.5" CALIPER, 5' GRAFT 2 HAMAECYPARIS OBTUSA'GRACILIS' TALL SLENDER HINOKI CYPRESS 6' HT., 4' O.C. SPACING 9 PSEUDOTSUGA MENZIESII DOUGLAS FIR 64HEIGHT, 5' O.0 SPACING 8 THUJA PLICATA WESTERN RED CEDAR 6'-8' HEIGHT, 3' O.0 SPACING 30 JUNIPERUS SCOPU LO RUM 'SKYROCKET' SKYROCKET JUNIPER 64HEIGHT, S O.0 SPACING 3 ACER CIRCINATUM'PACIFIC FIRE' PACIFIC FIRE VINE MAPLE 2" CALIPER, SPACING PER PLAN SHRUBS 14 MYRICA CALIFORNICA PACIFIC WAX MYRTLE 3 GALLON, 6' O.C. SPACING 19 RIBES SANGUINEUM RED FLOWERING CURRANT MIN. 18" HT., 4' O.C. SPACING 32 CISTUS X PURPUREA PURPLE ROCK ROSE MIN. 18" HT., 4' O.C. SPACING 48 RHODODENDRON `PURPLE GEM' PURPLE GEM AZALEA MIN. 18" HT., 3' O.C. SPACING 103 CORNUS SERICEA'KELSEYI' KELSEY DOGWOOD MIN. 18" HT., 3' O.C. SPACING 71 POLYSTICHUM MUNITUM SWORD FERN 1 GALLON, 3' O.C. SPACING GROUNDCOVERS 388 ARCTOSTAPHYLOS UVA-URSI VANCOUVER JADE KINNIKINNICK 1 GALLON, 30" O.C. SPACING 8 GAULTHERIA SHALLON SALAL 1 GALLON, 30" O.C. SPACING 170 CAREX OBNUPTA SLOUGH SEDGE 1 GALLON, 2' O.C. SPACING HYDROSEED BY COUNTRY GREEN TURF FARM 8 LBS PER 1000 SQ. FT. PERENNIAL RYEGRASS 80% FINE FESCUE 20% TREE PROTECTION FENCING, SEE DETAIL 111.00 'ED _LY TREE PROTECTION NOTES 1. A 6-FOOT HIGH TEMPORARY CHAIN LINK FENCE MUST BE PLACED WHERE SHOWN ON PLANS A MINIMUM OF FOUR BUSINESS DAYS PRIOR TO THE COMMENCEMENT OF WORK OR SITE DEMOLITION. VERIFY LOCATIONS WITH CIVIL. NOTIFY THE CLEARING AND GRADING INSPECTOR TO GET BOTH THE INSPECTION AND WRITTEN APPROVAL OF FLAGGED TREES AND TEMPORARY PROTECTION FENCING AROUND TREES TO BE SAVED PER THE APPROVED PLANS. 2. NO STOCKPILING OF MATERIAL AND NO VEHICULAR TRAFFIC ARE ALLOWED WITHIN THE LIMITS OF THE TEMPORARY FENCING. LIMIT INTRUSION INTO TREE DRIP ZONES WHEN POSSIBLE. FILLING, EXCAVATING, AND CLEARING WITHIN FENCED AREAS MUST BE ACCOMPLISHED BY HAND METHODS ONLY. 3. ROOTS OF TREES TO BE SAVED WHICH ARE DAMAGED DURING CONSTRUCTION WILL BE TREATED IN THE FOLLOWING WAY: FOR DAMAGED ROOTS OVER 1" IN DIAMETER, MAKE A CLEAN, STRAIGHT CUT TO REMOVE THE DAMAGED PORTION OF THE ROOT. ALL EXPOSED ROOTS WILL BE TEMPORARILY COVERED WITH DAMP BURLAP OR WOOD SHAVING TO PREVENT DRYING AND COVERED WITH EARTH AS SOON AS POSSIBLE. 4. PER RMC 4-4-130-H.9.f, ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED COMPLETELY AND EVENLY WITH A MINIMUM OF THREE INCHES (3") OF BARK MULCH PRIOR TO INSTALLATION OF THE PROTECTIVE FENCING. RESTRICTIONS: TREES TO BE PRESERVED SHALL BE DESIGNATED IN ACCORDANCE WITH APPROVED TREE PRESERVATION PLAN ON FILE WITH THE CITY OF RENTON. DESIGNATED TREES WHICH ARE DAMAGED OR DESTROYED SHALL BE REPLACED IN ACCORDANCE WITH RMC 4-4-130 TREE RETENTION AND LAND CLEARING REGULATIONS, OR AS HEREAFTER AMENDED. 1TREE PROTECTION FENCING SURVEYED: SCALE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/13/1991 DESIGNED: DRAWN: ZA STATE OF ZA WASHINGTON ONE INCH REGISTERED LANDSCAPE ARCHITECTS 1 PLANS REVISED PER COR 1 ST REVIEW COMMENTS ZA 4/09/25 CHECKED: EW DATUM LANDSCAPE_ ARCHITECT AT FULL SCALE 21 1 1 South C Street, Tacoma, WA 98402 IF NOT ONE INCH RIC J. WILLIAMS N 0. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY CERTIFICATE NO. 775 253-678-41 73 I Eric@LyonLA.com CITY OF RENTON Planning/Building/Public Works Dept. IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING HHuynh 07/21/2025 CURRENT PLANNING amorganroth 07/22/2025 DATE: FOR SUNSET MEDICAL OFFICE BUILDING CONSTRUCTION FIELDBOOK: PAGE: AHBL JOB #2230621.10 DRAWING N0: SHEET: 29 OF: 34 u N O O O N co T N O O O I N Q J LO C'7 C') 6 PLANT LEGEND ® CITY OF RENTON I PERMIT SERVICES TREE RETENTION AND CREDIT WORKSHEET 0 QTY I BOTANICAL NAME COMMON NAME SIZE & SPACING W TREES 3 CERCIDIPHYLLUM JAPONICUM KATSURA TREE 1.5" CALIPER, 5' GRAFT TREE RETENTION REQUIREMENTS N s 6 STYRAX JAPONICUS JAPANESE SNOWBELL 1.5" CALIPER, 5' GRAFT co A minimum retention of thirty percent (30%) of all significant trees (as defined in RMC 4-11-200) is required on site. O O 2 HAMAECYPARIS OBTUSA'GRACILIS' TALL SLENDER HINOKI CYPRESS 6' HT., 4' O.C. SPACING Please complete the form below to verify compliance with minimum tree retention requirements. O F 9 PSEUDOTSUGA MENZIESII DOUGLAS FIR 6'-8' HEIGHT, 5' O.0 SPACING Identify total number of trees 6-inch caliper or greater (or alder or N C 8 THUJA PLICATA WESTERN RED CEDAR 6'-8' HEIGHT, T O.0 SPACING cottonwood trees8-inch caliper or greater) on site: 4 Trees 0 + 30 JUNIPERUS SCOPULORUM 'SKYROCKET' SKYROCKET JUNIPER 6'-8' HEIGHT, T O.0 SPACING Deductions —Certain trees are excluded from the retention calculation: o° o Trees that are high -risk, as defined in RMC 4-11-200: Trees 3 ACER CIRCINATUM'PACIFIC FIRE' PACIFIC FIRE VINE MAPLE 2" CALIPER, SPACING PER PLAN o Trees within existing and proposed public right-of-way: Trees SHRUBS o Trees within wetlands, streams, very high landslide hazards, 14 MYRICA CALIFORNICA PACIFIC WAX MYRTLE 3 GALLON, 6' O.C. SPACING protected slopes, and associated buffers: 2 Trees • 19 RIBES SANGUINEUM RED FLOWERING CURRANT MIN. 18" HT., 4' O.C. SPACING 0Total remaining trees after deductions: 2 Trees 32 CISTUS X PURPUREA PURPLE ROCK ROSE MIN. 18" HT., 4' O.C. SPACING • Required tree retention (30%): 0.66666 Trees Required • Identify number of trees proposed for retention: 1 Trees Proposed O 48 RHODODENDRON 'PURPLE GEM' PURPLE GEM AZALEA MIN. 18" HT., 3' O.C. SPACING Identify number of trees requested for replacement in lieu of retention N C 103 CORNUS SERICEA'KELSEYI' KELSEY DOGWOOD MIN. 18" HT., 3' (skip page 3 if no tree replacement is requested): -0•4 Trees O.C. SPACING LO O 71 POLYSTICHUM MUNITUM SWORD FERN 1 GALLON, T O.C. SPACING O GROUNDCOVERS TREE CREDIT REQUIREMENTS O Tree credit requirements apply at a minimum rate of thirty (30) credits per net acre. Complete the form below to 4 388 ARCTOSTAPHYLOS UVA-URSI VANCOUVER JADE KINNIKINNICK 1 GALLON, 30" O.C. SPACING determine minimum tree credit requirements. N a 8 GAULTHERIA SHALLON SALAL 1 GALLON, 30" O.C. SPACING 0 Gross area of property in square feet: 35,593 Square Feet 170 CAREX OBNUPTA SLOUGH SEDGE 1 GALLON, 2' O.C. SPACING 0Deductions: Certain areas are excluded from tree credit calculation: o Existing and proposed public right-of-way: 1,200 Square Feet O Wetlands, streams, very high landslide hazards, protected slopes, HYDROSEED BY COUNTRY GREEN TURF FARM and associated buffers: 5,087 _ Square Feet • PERENNIAL RYEGRASS 80% Total excluded area: 6,287 Square Feet 8 LBS PER 1000 SQ. FT. FINE FESCUE 20% Net land area (after deductions) in square feet: 35,593 sf - 6,287 sf = 29,306 Square Feet • Net land area (after deductions) in acres: 0.673 Acres 00 T • Required tree credits: 0.673 * 30 credits = 20.19 Tree Credits Required N O O O N Q PLANT IMAGES TREE RETENTION AND CREDIT WORKSHEET J TREES SHRUBS/PERENNIALS PROPOSED TREE CREDITS Please complete the table below to calculate the total tree credits proposed for your project. Identify the quantity of trees for each tree category, after deducting trees within excluded areas, as shown in the previous section. 41 w TREE SIZE TREE CREDITS TREE QUANTITY TOTAL TREE CREDITS �.4' ~�r� Purple Rock Rose Purple Gem Azalea Pacific Wax Myrtle RETAINED TREES Preserved tree 6 9" caliper 4 0 Preserved tree 10 — 12" caliper 5 0 Preserved tree 12 — 15" caliper 6 0 °' T'\' ` _ K �! r t Preserved tree 16 — 18" caliper 7 0 Preserved tree 19 — 21" caliper 8 0 Preserved tree 22 — 24" caliper 9 0 Hinoki Cypress Pacific Fire Vine Maple Katsura Sword Fern Red Flowering (Current Kelsey Dogwood Preserved tree 25 — 28" caliper 10 1 10 Preserved tree 29 — 32" caliper 11 0 Preserved tree 33 — 36" caliper 12 0 GROUND COVERS/GRASSES _ r trr d t 1 0 . ,�°. • �„ `. .. ram, � & NEW TREES ! sib' vas New small species tree (30' or less at maturity) 0.25 44 11 New medium species tree (30' to 50' at maturity) 1 4 New large species tree (50' or more at maturity) 2 17 34 ,r Salal Kinninnick Slough Sedge 3, L�'^' ►� y y 2. `, •fir W 4 �. I-, 'A - - ► LixiTi�1 T ' S1ti "�I tt t • +�� IN COMPLIANCE WITH CITY OF RENTON STANDARDS Skyrocket Juniper Japanese Snowbell Douglas Fir Western Red Cedar a 0 STATE OF WASHINGTON REGISTERED LANDSCAPE ARCHITECTS Know what's below. LANDSCAPE ARCHITECT 21 1 1 South C Street, Tacoma, WA 98402 Cal before you dig. CERRITIFF CEJ. RTIFICATE 0. WILLIAMS 75 253-678-4173 1 Eric@)LyonLA.com LO C'7 C') i w WIDE BRANCH ATTACHMENT REMOVE BURLAP FROM TOP HALF OF ROOTBALL ROTOTILL COMPACTED SUBGRADE AS SPECIFIED STRONG STOUT STEMS AND BUDS COVER SOIL LOOSENED AREA WITH 2" BARK MULCH. KEEP MULCH 3" FROM TREETRUNK DIG THE PLANTING PIT AT LEAST 2 TIMES THE SIZE OF THE ROOTBALL I- ''1 ��. -'' I =1 I I1 I I1 I I1 I I1 �� 11 111 111 111 111 111 III =1 I �—III—I I —III —I I —I III III —III —III —I 1 I —I I-1 I - NOTE: —1 I I —III —I —I I III III-1=� 11=1 1. FERTILIZE AND WATER AS "� I SPECIFIED FOLLOWING PLANTING. SPECIFIED TOPSOIL 2. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. PLACE ROOTBALL ON SOLID SOIL 3. SEE STAKING DETAILS 1 DECIDUOUS TREE PLANTING DETAIL SCALE: NTS U) W z ry m O O m O DECIDUOUS TREE STAKING DETAIL SCALE: NTS NOTES: 1. FERTILIZE & WATER AS SPECIFIED FOLLOWING PLANTING. PLACE TOP OF 2. SEE SPECS FOR ADDITIONAL ROOTBALL 1"ABOVEAli INFORMATION 2� d'. LEVEL GROWING IN3. SEE STAKING DETAILS. �L NURSERY DIG THE PLANTING PIT AT LEAST TWICE THE SIZE OF THE ROOTBALL TILL COMPACTED SUBGRADE AS SPECIFIED iiI REMOVE BURLAP FROM TOP)/2 OF ROOTBALL CONIFER PLANTING DETAIL SCALE: NTS Know what's below. Call before you dig. COVER SOIL LOOSENED AREA WITH 2" MULCH. KEEP MULCH 3" AWAY FROM TREE TRUNK SOIL BACKFILL (SEE SPECS) PLACE ROOTBALL ON SOLID SOIL LL LL rro LL C. LL C\ CONIFER TREE STAKING SCALE: NTS YON STATE OF WASH INGTON REGISTERED LANDSCAPE ARCHITECTS LANDSCAPE _ ARCHITECT f__ 21 1 1 South C Street, Tacoma, WA 98402 RIG J. wILNO.LIAS 7 253-678-4173 1 Eric@LyonLA.com CERTIFICATE X TREE TIES _E STAKE. PLACE 3ALL TRATE 12" MIN. 1 OF PLANTING PIT CHAIN LOCK TREE TIE 0 LODGE POLE STAKE. -ACE JTSIDE )OTBALL NOTES: 1. USE PLANT STARTER SOLUTION DURING PLANTING OPERATION. FEED AS SPECIFIED. 2. SHRUBS SHALL BEAR SAME RELATION TO FINISHED GRADE AS IT BORE TO PREVIOUS / rlV EXISTING GRADE. TOP F ROOTBALL SHALL BE 1" ABOVE FINISHED GRADE 2" MULCH SAUCER REMOVE BURLAP FROM TOP% OF ROOT BALL SHRUB PLANTING DETAIL SCALE: NTS FIG z SPREAD ROOTS OF BASE ROOT PLANTS OUT OVER CONE OF HAND -FIRMED TOPSOIL CONE OF HAND -FIRMED TOPSOIL FOR BALL & BURLAP PLANTS MULCH, AS SPECIFIED 0 (0 & & 0 0 11 GROUNDCOVERS, ` EQ. _ TYP 1 FERTILIZER TABLETCn BACK OF CURB OR — CO - LANDSCAPE BED EDGE 6„ SPECIFIED TOPSOIL NOTE: I 11. ALL GROUNDCOVER SHALL BE PLANTED AT EQUAL TRIANGULAR SPACING AS PER PLAN, UNLESS SHOWN OTHERWISE 2. SET GROUNDCOVER BACK FROM CURB OR WALKWAY AT "� GROUNDCOVER PLANTING DETAIL LEAST 1-1/2 TIMES THE SPREAD OF SUCH GROUNDCOVER SCALE: NTS CM (0 O O Nt N LO O O O O N 00 N CD O O N Q J