HomeMy WebLinkAboutzW-4335setDROP -IN METER BY CITY FORCES. DROP -IN METER PERMIT REQUIRED EXISTING DOMESTIC - SERVICE LINE TO BE CUT AND CAPPED STA:1 +03.46, 0.00' AT MAIN BY CITY FORCES. CUT AND CAP 1-12"x10" TEE (MJxFL) PERMIT REQUIRED 1-10" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK WET TAP WILL BE IN ACCORDANCE WITH COR STD PLAN 300 6 1 ' SEE STANDARD PLAN 300.5 ON SHEET C5.1 .% / R C5.4 FOR CONNECTION DETAIL. 1�23. EXISTING FIRE HYDRANT \ STA:1 +82.04, 6.50' LT GJ / �( 1" IRRIGATION SERVICE CONNECTION /� P( �NC,12 \ PER COR STD PLAN 320.1 DROP -IN METER BY CITY FORCES. DROP -IN METER PERMIT / / ANITARY SEWER REQUIRED / MANHOLE I M 400.4 12" CONC NE IE 8" PVC 8. I /12" CO W 388 / B® °a / / S :1 +94.9 .16 LT 2 1-FIRE DEP MENT NNECTION FOUND INVERTED NAIL IN ST • 3.96, 0.00' / d ONCRETE POST, INCASED �E 1- 2.50 BEND (MJ S el ° i 1-CONC. THRUST B STA:2+10.34, 6.50' LT 1" WATER SERVICE CONNECTION 0 (BY CITY F(1R(F PER COR STD PLAN 323y�F T + 34, 0.00' 1-10"x "TEE (MJxFL) ° / FOUND INVERTED NAIL IN CONCRETE POST, INCASED / SANITARY SEWER MANHOLE RIM 400.93 8" CONC N 391.53 IE 1" DCVA FOR 12" CONC NE 390.88 IE IRRIGATION �-' / O cP, 6" CONC S 391.82 IE 12" CONC SW 390.90 IE S � JANIT SEWER MANHOLE RI 0.71 / p " CONC NE 388.8_1 FR 12" QE)NC 5W388.61 I GRAVEL- / i 6.50' ROW DEDICATION 6 �� I PROPOSED COMMERCIAL BUILDING i / PRPOSED MEDICAL /'OFFICE SHELL / 6,200 SF FOOTPRINT • FF: 399.50 1" WATER SER\/ACE AND RPBA BACKFLOW I a2 DEVICE SHAD BE PROVIDED INSIDE THE z ° BUILDING PAR COR STD DETAIL 350.2 LS / VA FIR BACKFLOW ASSEMBLY SHALL BE INSTALLED INSIDE THE BUILDING PER COR STD 0TA:2+13.34, 6.49 LT 1-PIV VALVE PER COR STD DTL 360.5 1-6 GATE VALVE (FLxMJ) :2/,T&34, 7.50' LT 1-CONC. THRUST BLOCK ER\FIRE HYDRANT ASSEM MANHOLE SANITARY SEWER FH ASSEMBLY PER COR ° ,4'X4' CON PAD PER RIM 398.25 STD PLAN 310.1, 310.2, 310.3 COR STD DTL 310.2 12" CONC NE 386.00 IE STA:2+21.28, 0.00' \ / \ 12" CONC SW 385.95 IE 1-10" POLYPIG STATION i PER COR STD PLAN 300.7 DETAIL 360.5. FIRE SERVICE LINES TO BE 4" DI CL 52. REFER TO FIRE PROTECTION NOTE ON SHEET C5.7 LO co M U) 2 SSCO #2 RIM:399.33 / IE: 393.80 8" (SW) LO IN / IE: 393.80 8" (SE) 1 I 36 LF 8" PVC @ 2.00% •� � II SSCO #1 RIM: 398.26 IE: 394.51 8" (NW) INSTALL SEWER SERVICE` 1-1 IE: 390.39 8" (E) CO # 5 LF 8" 8% RIM:399.41 GIA ENTERPRISES 6 LF 8" PVC @ 4.36% IE: 392.42 8" (NW) 0323059097 9j 35 LF 8" SSCO #6 IE: 392.42 8" (NE) / C0 RIM: 398.23 IN PVC @ 3.5 ° 8' /0 398 A IE: 390.65 8" (W) 4"FIR .:: � \ Q IE: 390.65 8" (E) � R91 I 9 3 � < 20' SEWER EASEMEN 16"FI "� 1.9 ) E: 8" SE) < WORKMAN ARLENE M. \ i 0323059055 .0"FI 16"FIRS Ix W W W I W _ / 3g6 I I 9 , I 30IR 24" FIRM / / 40 .00' STREAM �I BUFFS / �' V`tF 8 14"FIR l � \ . . . =� SANITARY SEWER MANHOLE - RIM 396.32 8" PVC S 393.35 IE 8" PVC SE 393.38 IE 8" PVC N 393.27 IE 164.55 N890 37; 58 W 16"FI 0" Fir /BECK HOLDINGS LLC 30 -393' % j / i ii 0323059044 F /� I f /-392- O pF WASgj���O�l 0 Q Q�� TACOMA • SEATTLE rl ;P 46972 wSPOKANE TRI-CITIES �,srsTER�O 2215 North 30th Street, Suite 300 Tacoma, WA 98403 Know what's below. SIGNAL E� 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Call before you diq. 07/21/2025 ° 2- ROCKERY SURVEYED: DESIGNED: QF DRAWN: QF 1 PLANS REVISED PER COR 1ST REVIEW COMMENTS QF 2/21/25 CHECKED: SK NO. REVISION BY DATE APPR APPROVED: SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY STREAM BUFFER EDGE OF STREAM STREAM BUFFER NCHMARK DA*C71TY CAL DATUM = NORTH AMERICAN VERTICAL M NAVD 88 (CITY OF RENTON) F RENTON SURVEY CONTROL POINT 2189 405 EXISTING ROAD CENTERLINE Ew STA: 1 +03.46 1-12"x10" TEE (MJxFL) 1-10" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK WET TAP WILL BE IN ACCORDANCE WITH COR STD PLAN 300.6. SEE STANDARD PLAN 300.5 ON SHEET C5.4 FOR CONNECTION DETAIL. 395 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY ELEVATION: 400.60' SITE NO.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH END OF 6' CYCLONE FENCE. ELEVATION: 396.77 PROPOSED ROW I BOUNDARY EXIST G ROW BOUNDARY PROPOSED GRADE AT SEC TION LINE \ EXISTING GRADE AT J SECTION LINE STA: 1 +55.75 EXISTING 12" STORM MAIN W.- -I IE:395.82 c�s2 T 1I 1 1 1.50' 1.50' i i 1 N GRAPHIC SCALE N 0 10 20 40 CY) O 1" = 20 FEET O N U LO 405 O O IN AREAS OF FILL, NEW ROADWAY SUBGRADE SHALL BE FILLED AND COMPACTED BEFORE EXCAVATION (V FOR INSTALLATION OF NEW WATER MAIN (TYP) 400 00 O T N - O O C) _ N STA: 1 +90.03 Q PROPOSED 6" ST RM _ J 395 STA: 2+21.28 1-10" POLYPIG STATION PER COR STD PLAN 300.7 1-22. ° BEND (MJ) / 1-CONC. TH UST BLOCK 22 LF 8" J STA: 2+16.34 5 LF 8" TA: 1+47.62 1-10' 6" TEE (MJxFL) 390 EXISTING 12" EWER MAIN 1- AT VALVE FLxM D.I. CL52 390 T.O.P: 389.29 1-CONC. HRUST BLOCK \ I FH ASS MBLY PER COR EX STING GRADE PROPOSED GRADE 387 AT SECTION LINE AT SECTION LINE 7 r7 �, 0 o cfl 00 o rno ao7 06Iq r10 o 0)0 WWCD 00 00 CDM M �`� M W W LL W LL WILL W LL 1+00 1+50 2+00 2+31.28 10 SITE SECTION 4 SCALE: H:1 "=20', V:1 "=2' W-433501 S-433501 R-433518 IN COMPLIANCE WITH CITY OF RENTON STANDARDS R DEVELOPMENT ENGINEERING ` • LHuynh 07/21/2025 '� WATER UTILITY WASTEWATER UTILITY U;%RW ABDOUL GAFOUR 07/25/2025 `� jstowell 07/28/2025 VERTICAL: NAVD 1988• SUNSET MEDICAL D I CAL OFFICE BUILDING DATE: FOR HORIZONTAL: NAD 1983/183/1991 CITY OF CONSTRUCTION FIELDBOOK: RENTON PAGE: ;R AHBL JOB #2230621.10 DATUM • DRAWING NO: Planning/Building/Public Works Dept. UTILITY PLAN C5.1 SHEET: 18 OF: 34 C'7 1 N Know what's below. Call before you d WATER PLAN GENERAL NOTES Standard Plan No. 300 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2. ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1-800-424-5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3. ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND "CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON -SITE. 4. ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. PIPE JOINTS SHALL BE PUSH -ON OR MECHANICAL JOINT. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/AWWA C110/A21.10-82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. 5. MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10-INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12-INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE-HALF OF PIPE MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD (MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6. CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS (OR SIMILAR PRODUCT) MAYBE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7. ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALLSUPPLY, INSTALLAND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. 8. NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BYTHE PUBLIC WORKS INSPECTOR. 9. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. Y o STD. PLAN — 300.0 WD PUBLIC WORKS WATER PLAN GENERAL NOTES .,AN DEPARTMENT N'T MARCH 2O10 WATER GENERAL NOTES NOT TO SCALE t+ T. kr WASFJ,, @� .� �SWIA�, �SSIONALE� T A C O M A S P O K A N E S E A T T L E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB TESTING CONNECTION EXISTING WATER MAIN POLYPIG STATION PER STD PLAN 300.7 (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING N'. g'± a d • Q �/� oOo NEW DI WATER MAIN 4 00 TEMPORARY BLOCKING CONNECTION TO EXISTING MAIN (BY CITY APPROVED WET TAP CONTRACTOR) 3 x ID (1) TAPPING TEE (FL) PER STD PLAN 300.6 MIN (1) TAPPING GATE VALVE (FLxMJ) (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH CONCRETE THRUST BLOCKING PER STD PLAN 330.1 tj FINAL CONNECTION UPON COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW -OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) (2) DI SPOOLS (1) LONG BODY DI SLEEVE (MJ) a a d • Q o o0O o NEW DI WATER MAIN 0 a NOTES: 1. ALL CONNECTIONS TO EXISTING WATER MAINS WILL BE CONDUCTED BY CITY FORCES AS SPECIFIED IN SECTION 5-14.2 OF THE CITY OF RENTON WATER UTILITY CONSTRUCTION STANDARDS 2. LONG BODY DI SLEEVE FOR CONNECTION FROM DI TO DI PIPE AND FROM DI TO CI PIPE WITH SAME OUTSIDE DIAMETER • STD. PLAN - 300.5 • PUBLIC WORKS CONNECTION TO WATER MAIN APPROVED: DEPARTMENT TAPPING TEE AND VALVE � 6/28/2023 Martin Pastucha DATE Public Works Administrator CONNECTION TO WATER MAIN TAPPING TEE AND VALVE ELEVATION NEW WATER MAIN CONCRETE SUPPORT BLOCKS COMPACTED BEDDING GRAVEL PER SECTION 9-03.12(3) OF THE WSDOT STANDARD SPECIFICATIONS NOTES: 1. WET TAPPING OF EXISTING WATER MAINS SHALL BE PERFORMED BY A CITY APPROVED WET TAP CONTRACTOR (SPEER TAPS, INC., LEGACY TAPPING, INC. OR OTHER FIRM APPROVED BY CITY ENGINEER). 2. CONTRACTOR SHALL POTHOLE AND VERIFY THE HORIZONTAL AND VERTICAL ALIGNMENT OF EXISTING WATER MAIN AND SHALL LAY THE NEW WATER MAIN TO MATCH. 3. TAPPING TEE SHALL BE STAINLESS STEEL OR STEEL WITH FULL CIRCLE SEAL WITH CORTEN OR STAINLESS STEEL NUTS AND BOLTS. 4. ALL TEES AND VALVES SHALL BE WATER TESTED BEFORE TAPPING OR ASSEMBLY SEALS SHALL BE TESTED VIA AIR PRESSURE AFTER THE TAPPING SLEEVE IS INSTALLED TO THE MAIN AND THE TAPPING VALVE IS INSTALLED. 5. TAPPING TEES MAY BE SIZE -ON -SIZE, PROVIDED THE SHELL CUTTER DIAMETER IS AT LEAST 2" SMALLER THAN THE EXISTING MAIN DIAMETER. 6. TAPPING TEES SHALL NOT BE INSTALLED ON STEEL OR ASBESTOS CEMENT WATER MAINS. • STD. PLAN - 300.6 .-} PUBLIC WORKS APPROVED: TAPPING TEE - DEPARTMENT J 6/28/2023 Martin ha Public Work cAdministrator DATE TAPPING TEE NOT TO SCALE W-433502 N C'D (0 O O Nt N A, u N 0 C) i N KOE N O O O N Q D J 07/21 /2025 C'7 C'7 N Know what's below. Call before you dig. NOTES: 1. FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF SAFETY YELLOW DTM ACRYLIC GLOSS OR ENAMEL PAINT. 2. PUMPER NOZZLE TO FACE ROADWAY OR AS DIRECTED BY RRFA. 3. A MINIMUM 3' RADIUS UNOBSTRUCTED WORKING AREA SHALL BE PROVIDED AROUND THE OUTSIDE OF THE HYDRANT. KA ATCDI AI f O HYDRANT O TEE OC VALVE OD VALVE BOX OE PIPE OF JOINT RESTRAINT OG GRAVEL OH CONCRETE BLOCK OI BLOCKING JO SHEAR BLOCK O PAVEMENT MARKER COMPRESSION TYPE HYDRANT (SEE APPROVED MATERIALS LIST) WITH 6" MJ INLET WITH LUGS, 5 %4" MVO, 1 %4" PENTAGON OPERATING NUT, TWO (2) 2 %" NST HOSE NOZZLES, AND 4.875" SST PUMPER NOZZLE EQUIPPED WITH 5" STORZ ADAPTER AND 1/8" STAINLESS STEEL CABLE, WITH EXTENSION IF NECESSARY. MAIN LINE TEE WITH 6" FLANGE SIDE OUTLET 6" GATE VALVE (FLxMJ) VALVE BOX AND LID PER STD PLAN 330.7 AND CLASS 52 DI, LENGTH TO FIT MECHANICAL JOINT RESTRAINT WITH CONCRETE BLOCKING (2) 3/4" CORTEN STEEL TIE RODS 1 %4" WASHED DRAIN ROCK, MINIMUM 1' ABOVE BOOT FLANGE WITH 8-MIL POLYETHYLENE SHEETING AROUND TOP AND SIDES OF GRAVEL MINIMUM 16"x8"x4" CONCRETE BLOCKS UNDER FIRE HYDRANT AND GATE VALVE CONCRETE BLOCKING PER STD PLAN 330.1 4'x4'x6" CONCRETE SHEAR BLOCK AROUND FIRE HYDRANT, SEE STANDARD DETAIL 310.2 BLUE REFLECTIVE PAVEMENT MARKER PER STD PLAN 310.3 STD. PLAN - 310.1 PUBLIC WORKS APPROVED: CAIR) DEPARTMENT FIRE HYDRANT ASSEMBLY J 6/28/2023 Martin Pastuchavur DATE Public Works Administrator FIRE HYDRANT ASSEMBLY NOT TO SCALE T A C O M A S E A T T L E 16rt w�69S P O K A N E T R I- C I T I E S ��102215 North 30th Street, Suite 300 Tacoma, WA 98403 NAL253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB 07/21 /2025 FIRE HYDRANT PAVEMENT MARKER NOT TO SCALE FINISHED GRADE 9" TO 12" d d a \ 24" TO 30" A /jam 221v MAIN LOOP DOWN TO CENTERLINE OF WATER MAIN TO PROVIDE SLACK IN SERVICE LINE TO METER MATERIALS O CORPORATION STOP O TUBING OC METER SETTER OD WATER METER OE METER BOX OF COUPLER AND PLUG OG GRAVEL W Z J w Z - IN UNIMPROVED ROW, J w INSTALL METER BOX Cr CITY PRIVATE p AT PROPERTY LINE WITH p r a 1" COPPER TAILPIECE a PIPING PIPING SIDEWALK I �12"� 21" TO 30" G g 1" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET, FORD FB1000-4-Q-NL OR A.Y. MCDONALD 74701BQ 1" TYPE "K" SOFT COPPER TUBING 1" SETTER, QUICK JOINT INLET AND OUTLET, PADLOCK WINGS ON INLET ANGLE BALL VALVE, SINGLE CHECK VALVE ON OUTLET, FORD VBH74-15W-44-44-Q-NL, A.Y. MCDONALD 721-415WCQQ 44, OR MUELLER B-24701-6AN, INSTALL CENTERED AND SQUARED IN METER BOX, PROVIDE ADAPTERS FOR 5/8"x3/4" METERS AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BY THE CITY METER BOX, ARMORCAST A6001946PCX18, WITH METER BOX LID, ARMORCAST A6001969RC1-H7, TO READ "RENTON WATER" COUPLER (PACK JOINT x PACK JOINT), FORD C4#-4#-Q-NL, WITH 1" GALVANIZED PLUG IF SERVICE LINE TO PROPERTY IS TO BE INSTALLED IN THE FUTURE 114" WASHED GRAVEL PUBLIC WORKS DEPARTMENT 1" WATER SERVICE 1 INCH WATER SERVICE NOT TO SCALE Pastucha STD. PLAN - 320.1 UHIt W-433503 N C'D (C) O O Nt N A, u KOE N O C) C) N Q D J C'7 C'7 i N 900 BEND CAP / PLUG TEE 450 BEND 2212° BEND 1114- BEND B o E, MINIMUM BEARING AREA AGAINST UNDISTURBED SOIL (SF) * PIPE SIZE PRESSURE O O O O O 4„ 200 2/(1) 1/(NONE) 1/(NONE) NONE NONE 300 3/(2) 2/(2) 2/(1) 1/(1) NONE 6" 200 4/(3) 3/(2) 3/(1) 1/(1) 1/(NONE) 300 6/(4) 4/(3) 3/(2) 2/(1) 1/(NONE) 8„ 200 7/(5) 5/(3) 4/(3) 2/(2) 1/(1) 300 11/(8) 8/(5) 6/(4) 3/(2) 2/(1) 10" 200 11/(8) 8/(6) 6/(4) 3/(2) 2/(1) 275 16/(11) 11/(7) 9/(6) 11/(8) 9/(6) 5/(3) 3/(2) 12" 200 16/(11) 5/(3) 3/(2) 250 24/(16) 17/(11) 13/(9) 16/(11) 12/(8) 7/(5) 4/(3) 14 200 22/(13) 6/(4) 3/(2) 250 33/(22) 23/(16) 18/(12) 9/(6) 5/(3) 16" 200 29/(19) 21/(14) 16/(11) 8/(6) 5/(3) 225 32/(21) 23/(16) 17/(12) 9/(6) 5/(3) 18" 200 36/(24) 26/(17) 20/(13) 10/(7) 5/(4) 20" 200 45/(29) 32/(21) 24/(16) 13/(8) 7/(4) 24" 200 64/(43) 46/(30) 35/(23) 18/(12) 9/(6) * VALUES BASED ON SAFE BEARING LOAD OF 2,000/(3,000) PSF SOIL TYPE MUCK OR PEAT SOFT CLAY SAND SAND AND GRAVEL CEMENTED WITH CLAY HARD SHALE NOTES: 1. MINIMUM BEARING AREA MUST BE ADJUSTED FOR PIPE SIZE, PRESSURE, AND SOIL CONDITIONS. 2. FITTINGS SHALL BE POLYWRAPPED PRIOR TO POURING CONCRETE BLOCKING. SAFE BEARING LOAD (PSF) 0 1,000 2,000 3,000 4,000 10,000 3. CONCRETE BLOCKING SHALL BE CAST IN PLACE AND SHALL HAVE A MINIMUM OF 0.25 SF BEARING AREA AGAINST THE FITTING. 4. CONCRETE BLOCKING SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE CLEAR OF JOINTS TO PERMIT TAKING UP OR DISMANTLING JOINT. S. CONTRACTOR SHALL INSTALL BLOCKING ADEQUATE TO WITHSTAND FULL HYDROSTATIC TEST PRESSURE AS WELL AS TO CONTINUOUSLY WITHSTAND OPERATING PRESSURE UNDER ALL CONDITIONS OF SERVICE. 6. ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. 7. IN MUCK OR PEAT, ALL THRUSTS SHALL BE RESTRAINED BY PILES OR TIE RODS TO SOLID FOUNDATION OR MUCK OR PEAT SHALL BE REMOVED AND REPLACED WITH BALLAST OF SUFFICIENT STABILITY TO RESIST THRUST. 8. CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS. STD. PLAN - 330.1 PUBLIC WORKS CONCRETE BLOCKING APPROVED: 1.1-151*1 DEPARTMENT FOR HORIZONTAL FITTINGS 6/28/2( • Martin Pastucha 1%09Public Works Administrator DATE CONCRETE BLOCKING FOR HORIZONTAL FITTINGS NOT TO SCALE pF �VASgj���01.G TACOMA SEATTLE rt 46972 �sv� SPOKANE TRI-CITIES �.��5��'GISTEg�9 Gti 2215 North 30th Street, Suite 300 Tacoma, WA 98403 Know what's below. SIONAL E� 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Call before you dig. 07/21/2025 METERED BACKFLOW ASSEMBLY (TO BE OBTAINED FROM CITY) (1) 2'2" CONTROL VALVE (1) CONSTRUCTION METER (1) RPBA METER SUPPORT (BY CONTRACTOR) NSF 61 SUPPLY HOSE I LIV I r"11 RMRI DLVLI\I IVQ HYDRANT ON EXISTING WATER MAIN TEMPORARV RI nMLnCC Acc CRARl V (1) 2" GAL (1) 2" 90° (1) 2" GAT NEW DI WATER MAIN POLYPIG STATION (1) VERTICAL CROSS (M1xFL), SIZE TO MATCH WATER MAIN (1) BLIND FLANGE WITH 2" TAP ON TOP OF CROSS (1) TEMPORARY BLOW -OFF ASSEMBLY (1) BLIND FLANGE ON BOTTOM OF CROSS (1) PLUG (MJ) ON END OF CROSS WITH TEMPORARY THRUST BLOCKING NOTES: 1. THE BACKFLOW PREVENTION ASSEMBLY AND SUPPLY HOSE MUST BE DISCONNECTED DURING HYDROSTATIC PRESSURE TESTING OF THE NEW WATER MAIN. 2. POLYPIG AND ALL DEBRIS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS VIA SANITARY METHOD PRIOR TO DISINFECTION OF NEW WATER MAIN. 3. UPON REMOVAL OF POLYPIG, REMOVE TEMPORARY BLOW -OFF ASSEMBLY AND INSTALL 2" PLUG. 4. THE NEW WATER MAIN SHALL BE CONNECTED TO THE EXISTING SYSTEM ONLY AFTER NEW WATER MAIN IS POLYPIGGED, DISINFECTED AND SATISFACTORY BACTERIOLOGICAL SAMPLE RESULTS ARE OBTAINED. 5. THE INTERIORS OF ALL PIPES AND FITTINGS TO BE USED IN FINAL CONNECTION MUST BE SWABBED OR SPRAYED WITH A 5-6% AVAILABLE CHLORINE SOLUTION. STD. PLAN - 300.7 PUBLIC WORKS APPROVED: '�1` DEPARTMENT POLYPIGGING NEW WATER MAINS - J 6/28/2( Martin Pastucha DATE Public Works Administrator ;N POLYPIGGING NEW WATER MAINS TO ME I—'LHIN BOXES DRAINING GRAVEL NOTES: 1. ALL DOUBLE CHECK VALVE ASSEMBLIES (DCVA's) MUST BE LISTED ON LATEST LIST OF "BACKFLOW PREVENTION ASSEMBLIES APPROVED FOR INSTALLATION IN WASHINGTON STATE", PUBLISHED BY STATE OF WASHINGTON DEPARTMENT OF HEALTH. 2. THE OWNER/APPLICANT MUST OBTAIN A SEPARATE CITY OF RENTON PLUMBING PERMIT FOR THE INSPECTION OF THE INSTALLATION OF THE DCVA AND PIPING. THE OWNER SHALL FURNISH, INSTALL AND MAINTAIN THE DCVA AND ALL PIPING AND APPURTENANCES SHOWN ON THIS PLAN. 3. THE DCVA MUST BE TESTED BY A STATE CERTIFIED BACKFLOW ASSEMBLY TESTER AFTER ITS INITIAL INSTALLATION, AFTER REPAIRS AND ANNUALLY THEREAFTER AT OWNER'S EXPENSE. A COPY OF THE TEST REPORT SHALL BE SENT OR FAXED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPT., ATTN: WATER UTILITY CROSS —CONNECTION CONTROL SPECIALIST, FAX NO. 425-430-7241. 4. DCVA AND METER BOX SHALL BE LOCATED ON PRIVATE PROPERTY AND AS NEAR AS POSSIBLE TO THE WATER METER. Y ► PUBLIC WORKS 34�� TO 2" DOUBLE CHECK VALVE STD. PLAN — 340.8 ' DEPARTMENT ASSEMBLY FOR IRRIGATION OR C RESIDENTIAL FIRE SPRINKLER MARCH 2O10 DOUBLE CHECK VALVE ASSEMBLY NOT TO SCALE W-433504 N C') (C) O O Nt N A, u O O O i N O O O i N Q D J WATER UTILITY NOTES & SPECIFICATIONS L/ M 1 N 1 1♦ 1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AT (425) 430-7301. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATES CALL 48-HOUR LOCATORS 800-424-5555. 4. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AT THE PRE -CONSTRUCTION MEETING. 5. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6. ALL WATERMAIN PIPE IS TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. 7. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-87. CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/421/4-90. IF FITTINGS ARE 3 TO 12 INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL IN ACCORDANCE WITH EITHER ANSI/AWWA C110-A21.10-87 OR ANSI/AWWA C153/A21.53-94. THREE (3) INCH TO 12 INCH DIAMETER FITTINGS, WHICH HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS, SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.87 OR A COMBINATION OF ANSI/AWWA C110/A21.10.87 AND ANSI/AWWA C153/A21.53-94 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE WITH ANSI/AWWA C153/A21.53-94 AND THAT PORTION OF THE FITTING WITH FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH AWWA C11O/A21.10-87. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53.53 OF ANSI/AWWA SECTION 10-4.3 OF ANSI/AWWA C11O/A21.10-87 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 8. GATE VALVES SHALL BE IRON BODY, BRONZED -MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND O-RING STUFFING BOX (AWWA C500) OR OF RESILIENT SEATED TYPE (AWWA C509). VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380, M & H, OR APPROVED EQUAL. 9. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR COMPRESSION TYPE (OPENING AGAINST PRESSURE) CONFORMING TO AWWA C-502-85 WITH A 6 INCH MECHANICAL JOINT INLET AND A MAIN VALVE OPENING (M.V.O.) OF 5-1/4 INCH, TWO 2-1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD THREADS 7-1/2 THREADS PER INCH AND ONE 4 INCH PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH, 60 DEGREES V. THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND ROOT DIAMETER 4.6263. HYDRANTS SHALL HAVE A 1-1/4 INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT). 10. THE TWO 2-1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND PROPORTIONS AS THE HYDRANT STEM NUT. CAPS SHALL BE FITTED WITH SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST PRESSURES. 11. THE 4 INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4 INCH SEATTLE THREAD X 5 INCH STORZ. STORZ ADAPTER SHALL BE FORGED AND/OR EXTRUDED 6061-T6 ALUMINUM ALLOY, HARDCOAT ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET SCREWS 180 DEGREES APART. STORZ FACE TO BE METAL, NO GASKET TO WEATHER. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8 INCH, COATED, STAINLESS STEEL, AIRCRAFT CABLE. 12. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT NUMBER 43-655 SAFETY YELLOW OR APPROVED EQUAL. 13. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. 14. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAIL FOR FIRE HYDRANTS,LATEST REVISION. 15. ALL WATERMAINS 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATERMAIN 12 INCHES AND LARGER SHALL BE AT A MINIMUM OF 48 INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATERMAINS ARE TO BE LOWERED TO CLEAR. 16. ALL WATERMAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL, 2 LB/CU. FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY. 17. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 18. ALL WATERMAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY OF RENTON STANDARD PLANS & SPECIFICATIONS 7-11.3(11). THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 19. ALL WATERMAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METERED/INJECTED IN ACCORDANCE WITH SECTION 7-11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED ABOVE. 20. A PRE -CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. 21. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 22. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 23. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE CITY OF RENTON. 24. ALL CONNECTION TO EXISTING MAINS IS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS, WHICH MAY BE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE ON -SITE PRIOR TO CITY NOTIFICATIONS. 25. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS. 26. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 27. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. 28. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES. OIL MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 29. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN 10 DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. * 30. FOR CITY PROJECTS SUCH AS TELEMETRY CONDUIT, THE PVC PIPE USED SHALL BE ALL CHEMICAL PROCESS LINES SHALL BE SCHEDULE 80 PVC PIPE. SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 PVC PIPE UNDER IMPROVED AREAS. Know what's below. Call before you dig. t+ T . kr @� 46972sv� GISTVV� �SSIONAL 07/21 /2025 T A C O M A SEATTLE S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB CITY OWNED AND MAINTAINED O O z a W r W z 3 J } U H W W a. d PRIVATELY OWNED AND MAINTAINED MAXIMUM PIPE LENGTH FROM PROPERTY LINE TO DDCVA MUST NOT EXCEED 50 FEET •�4 4 CONCRETE BOLLARDS •'� 03 10 a z 0.l z W f W a C3 O FT. MAX. 13 12 11 DDCVA MUST BE INSTALLED IMMEDIATELY AFTER PIPE PIPE PENETRATION THROUGH BUILDING FLOOR SLAB. ROOM IN WHICH DDCVA IS LOCATED SHALL: A. HAVE FLOOR DRAIN CONNECTED TO THE SANITARY SEWER SYSTEM. B. HAVE A HEATING SYSTEM (40• F MIN. TEMP.) NO HEAT TAPE C. NOT BE USED FOR STORAGE AROUND THE DDCVA D. HAVE CLEARLY DELINEATED ACCESS WAYS TO DDCVA AND PIVs. A RIGHT -OF -ENTRY AGREEMENT MUST BE GRANTED TO THE CITY OF RENTON FOR INSPECTION OF THE DDCVA AND METER. SEPARATE FIRE SPRINKLER PLANS INCLUDING INSTALLATION OF DDCVA MUST BE SUBMITTED TO RENTON REGIONAL FIRE AUTHORITY FOR REVIEW AND APPROVAL. A SEPARATE FIRE SPRINKLER PERMIT IS REQUIRED. 1. MAIN LINE TEE (MJ x FL) WITH CONCRETE BLOCKING (WATER MAIN LOCATED IN EASEMENT ON PRIVATE PROPERTY SHALL NOT BE MORE THAN 50 FEET TO BUILDING) 2. BRANCH VALVE (FL x MJ) WITH VALVE BOX AND COVER 3. CLASS 52 DUCTILE IRON PIPE (4 INCH MINIMUM) ALL PIPE AND FITTINGS SHALL BE RESTRAINED WITH SHACKLE RODS AND CONCRETE THRUST BLOCKS PER NFPA AND AWWA STANDARDS. 4. POST -INDICATOR VALVE (MJ) WITH TAMPER SWITCH 5. 2-90• BENDS (FL x FL) WITH FLANGED DUCTILE IRON PIPE SPOOL 6. 18" LONG SPOOL (FL x PE) 7. FLANGE COUPLING ADAPTOR 8. APPROVED DDCVA ON MAIN LINE IN HORIZONTAL POSITION ONLY. (PER LATEST DEPT. OF HEALTH APPROVED LIST OF BACKFLOW PREVENTION DEVICES) BOTTOM OF DDCVA SHALL BE A MINIMUM OF 24 INCH ABOVE FLOOR LEVEL AND NOT HIGHER THAN 3 FEET MAXIMUM. INSTALL 3 CONCRETE PADS OR ADJUSTABLE PIPE SUPPORT COLUMNS UNDER DDCVA 9. 0 ' S & Y VALVES TO BE RESILIENT SEATED WITH TAMPER SWITCHES. ADD WIRING IN ACCORDANcE WITH L & I 10. METERED 3/4 INCH BY-PASS DCVA - BY-PASS METER SHALL BE A 3/4 INCH "SENSUS-ECR" SR POSITIVE DISPLACEMENT METER EQUIPPED ICE REGISTER WITH A REMOTE READ SENSOR PLATE MOUNTED ON THE OUTSIDE OF THE BUILDING WALL (WALL MOUNT TYPE). 11. SWING TYPE GRAVITY CHECK VALVE, FLANGE WITH BALL DRIP IN VAULT OR OUTSIDE BUILDING 12. 4"x 4" x 6" BULL, ELBOW, THREADED 13. UL LISTED FIRE DEPT. CONNECTION, UL LISTED BREAK AWAY CAPS, LOCATE WITHIN 50 FEET MAXIMUM OF A PUBLIC FIRE HYDRANT. AFTER FIELD INSTALLATION, MAIN DDCVA AND BY-PASS DCVA MUST BE TESTED SATISFACTORILY BY A DEPARTMENT OF HEALTH CERTIFIED BACKFLOW ASSEMBLY TESTER. TEST REPORT MUST BE SUBMITTED TO CITY OF RENTON WATER UTILITY ENGINEERING DEPARTMENT PRIOR TO ACTIVATION OF NEW LINE. INSTALL BRASS Y4" FLARE TEST COCKS WITH Y4" FLARE CAPS BUILDING WALL U to N I� a 10 0 8 Y i 0 J J O m F O 0 z 0 z_ 0 J_ 4 INCH N 48 INCH M m of J Y W 0 w z H o N s r m N 2 W w W J `L L� oa F (n PERIMETERS OF MINIMUM CLEARANCES TO BE PAINTED ON FLOOR IN WHITE ENAMEL PAINT STRIPE, WITH 2 INCH STENCILED BLACK LETTERS TO SAY: "DO NOT BLOCK ACCESS" STANCHIONS BOLTED TO FLOOR. Y STD. PLAN -360.5 INSIDE BUILDING INSTALL FOR 3" AND APPROVED: PUBLIC WORKS + + DEPARTMENT LARGER DETECTOR DOUBLE CHECK -� �FNSo� VALVE ASSEMBLY 6/28/2023MartinPastucha P.blir W.,ksAdmi.istn l,.r DATE 3-INCH AND LARGER DETECTOR DCVA INSIDE BUILDING INSTALL 2-1/2" FDC INLET WITH TWO-WAY FREE STANDING CHROME - LOCKING FDIC CAPS PLATED FIRE DEPARTMENT CONNECTION MANUFACTURED BY WITH 1" MIN. HIGH LETTERS "AUTO SPKR" KNOX PRODUCTS 0 0 METAL ADDRESS PLATE WELDED ON POST OR ATTACHED BY U-BOLT AND CHAIN, 24" MIN. N ABOVE GRADE AND 1" MIN. HIGH LETTERS. M 18" X 18" X 8" CONC. BLOCK GRADE FIRE DEPARTMENT CONNECTION NOT TO SCALE CUT FILL 3LOCK T MIN RADIUS jUNOBSTRUCTED WORKING AREA AROUND OUTSIDE OF FIRE HYDRANT TE SHEAR BLOCK NOTE: 4'x4'x6" CONCRETE SHEAR BLOCK AROUND FIRE HYDRANT WITH EXPANSION JOINT AT BACK OF SIDEWALK, FINISH TO MATCH SIDEWALK, ALL CONCRETE SHALL BE MINIMUM 3,000 PSI AND SHALL BE MECHANICALLY MIXED - JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED. `�T Y 0" + + :FNT0P FIRE HYDRANT ASSEMBLY SHEAR BLOCK FIRE HYDRANT SHEAR BLOCK NOT TO SCALE STD. PLAN - 310.2 Martin Pastucha Public Works Administrator FIRE PROTECTION NOTES DATE THE FIRE PROTECTION SYSTEM INCLUDING MATERIALS, SIZING, AND CONFIGURATION IS SUBJECT TO A CONTRACTOR PROVIDED DESIGN BY A FIRE PROTECTION ENGINEER, AND AS SUCH, THE FINAL DESIGN OF THE FIRE PROTECTION SYSTEM MAY DEVIATE FROM THE SYSTEM SHOWN. THE FIRE PROTECTION SYSTEM AS SHOWN FROM THE MAIN LINE TO THE CONNECTION AT THE BUILDING SPRINKLER IS INTENDED FOR LOCATION OF THE FIRE HYDRANTS AND FIRE DEPARTMENT CONNECTION ONLY. CONTRACTOR'S BID SHALL REFLECT THE CONDITIONS OF THE FIRE PROTECTION ENGINEER'S DESIGN. CONTRACTOR SHALL COMPLY WITH ALL NATIONAL FIRE PROTECTION ASSOCIATION REQUIREMENTS AS SET FORTH BY "NFPA 13", ITS AMENDMENTS, AND LOCAL REQUIREMENTS, INCLUDING BUT NOT LIMITED TO ACQUISITION OF ALL PERMITS. FIRE SPRINKLER NOTE WHERE THE UNDERGROUND WATER SUPPLY TEES OFF TO SERVE ONLY A FIRE SPRINKLER SYSTEM AND/OR FIRE HYDRANTS, A SEPARATE DETAILED PLAN MUST BE SUBMITTED AND APPROVED BY THE FIRE MARSHAL PRIOR TO INSTALLATION. W-433505 , �i N LO C) C) O N I..L r� N C) C) I N Q D J