HomeMy WebLinkAboutzS-4335setDROP -IN METER BY CITY FORCES. DROP -IN METER PERMIT REQUIRED EXISTING DOMESTIC - SERVICE LINE TO BE CUT AND CAPPED STA:1 +03.46, 0.00' AT MAIN BY CITY FORCES. CUT AND CAP 1-12"x10" TEE (MJxFL) PERMIT REQUIRED 1-10" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK WET TAP WILL BE IN ACCORDANCE WITH COR STD PLAN 300 6 1 ' SEE STANDARD PLAN 300.5 ON SHEET C5.1 .% / R C5.4 FOR CONNECTION DETAIL. 1�23. EXISTING FIRE HYDRANT \ STA:1 +82.04, 6.50' LT GJ / �( 1" IRRIGATION SERVICE CONNECTION /� P( �NC,12 \ PER COR STD PLAN 320.1 DROP -IN METER BY CITY FORCES. DROP -IN METER PERMIT / / ANITARY SEWER REQUIRED / MANHOLE I M 400.4 12" CONC NE IE 8" PVC 8. I /12" CO W 388 / B® °a / / S :1 +94.9 .16 LT 2 1-FIRE DEP MENT NNECTION FOUND INVERTED NAIL IN ST • 3.96, 0.00' / d ONCRETE POST, INCASED �E 1- 2.50 BEND (MJ S el ° i 1-CONC. THRUST B STA:2+10.34, 6.50' LT 1" WATER SERVICE CONNECTION 0 (BY CITY F(1R(F PER COR STD PLAN 323y�F T + 34, 0.00' 1-10"x "TEE (MJxFL) ° / FOUND INVERTED NAIL IN CONCRETE POST, INCASED / SANITARY SEWER MANHOLE RIM 400.93 8" CONC N 391.53 IE 1" DCVA FOR 12" CONC NE 390.88 IE IRRIGATION �-' / O cP, 6" CONC S 391.82 IE 12" CONC SW 390.90 IE S � JANIT SEWER MANHOLE RI 0.71 / p " CONC NE 388.8_1 FR 12" QE)NC 5W388.61 I GRAVEL- / i 6.50' ROW DEDICATION 6 �� I PROPOSED COMMERCIAL BUILDING i / PRPOSED MEDICAL /'OFFICE SHELL / 6,200 SF FOOTPRINT • FF: 399.50 1" WATER SER\/ACE AND RPBA BACKFLOW I a2 DEVICE SHAD BE PROVIDED INSIDE THE z ° BUILDING PAR COR STD DETAIL 350.2 LS / VA FIR BACKFLOW ASSEMBLY SHALL BE INSTALLED INSIDE THE BUILDING PER COR STD 0TA:2+13.34, 6.49 LT 1-PIV VALVE PER COR STD DTL 360.5 1-6 GATE VALVE (FLxMJ) :2/,T&34, 7.50' LT 1-CONC. THRUST BLOCK ER\FIRE HYDRANT ASSEM MANHOLE SANITARY SEWER FH ASSEMBLY PER COR ° ,4'X4' CON PAD PER RIM 398.25 STD PLAN 310.1, 310.2, 310.3 COR STD DTL 310.2 12" CONC NE 386.00 IE STA:2+21.28, 0.00' \ / \ 12" CONC SW 385.95 IE 1-10" POLYPIG STATION i PER COR STD PLAN 300.7 DETAIL 360.5. FIRE SERVICE LINES TO BE 4" DI CL 52. REFER TO FIRE PROTECTION NOTE ON SHEET C5.7 LO co M U) 2 SSCO #2 RIM:399.33 / IE: 393.80 8" (SW) LO IN / IE: 393.80 8" (SE) 1 I 36 LF 8" PVC @ 2.00% •� � II SSCO #1 RIM: 398.26 IE: 394.51 8" (NW) INSTALL SEWER SERVICE` 1-1 IE: 390.39 8" (E) CO # 5 LF 8" 8% RIM:399.41 GIA ENTERPRISES 6 LF 8" PVC @ 4.36% IE: 392.42 8" (NW) 0323059097 9j 35 LF 8" SSCO #6 IE: 392.42 8" (NE) / C0 RIM: 398.23 IN PVC @ 3.5 ° 8' /0 398 A IE: 390.65 8" (W) 4"FIR .:: � \ Q IE: 390.65 8" (E) � R91 I 9 3 � < 20' SEWER EASEMEN 16"FI "� 1.9 ) E: 8" SE) < WORKMAN ARLENE M. \ i 0323059055 .0"FI 16"FIRS Ix W W W I W _ / 3g6 I I 9 , I 30IR 24" FIRM / / 40 .00' STREAM �I BUFFS / �' V`tF 8 14"FIR l � \ . . . =� SANITARY SEWER MANHOLE - RIM 396.32 8" PVC S 393.35 IE 8" PVC SE 393.38 IE 8" PVC N 393.27 IE 164.55 N890 37; 58 W 16"FI 0" Fir /BECK HOLDINGS LLC 30 -393' % j / i ii 0323059044 F /� I f /-392- O pF WASgj���O�l 0 Q Q�� TACOMA • SEATTLE rl ;P 46972 wSPOKANE TRI-CITIES �,srsTER�O 2215 North 30th Street, Suite 300 Tacoma, WA 98403 Know what's below. SIGNAL E� 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB Call before you diq. 07/21/2025 ° 2- ROCKERY SURVEYED: DESIGNED: QF DRAWN: QF 1 PLANS REVISED PER COR 1ST REVIEW COMMENTS QF 2/21/25 CHECKED: SK NO. REVISION BY DATE APPR APPROVED: SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY STREAM BUFFER EDGE OF STREAM STREAM BUFFER NCHMARK DA*C71TY CAL DATUM = NORTH AMERICAN VERTICAL M NAVD 88 (CITY OF RENTON) F RENTON SURVEY CONTROL POINT 2189 405 EXISTING ROAD CENTERLINE Ew STA: 1 +03.46 1-12"x10" TEE (MJxFL) 1-10" GATE VALVE (FLxMJ) 1-CONC. THRUST BLOCK WET TAP WILL BE IN ACCORDANCE WITH COR STD PLAN 300.6. SEE STANDARD PLAN 300.5 ON SHEET C5.4 FOR CONNECTION DETAIL. 395 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET SITE NO. 1 SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY ELEVATION: 400.60' SITE NO.2 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF LIGHT STANDARD, 27' NORTHEAST OF SOUTH END OF 6' CYCLONE FENCE. ELEVATION: 396.77 PROPOSED ROW I BOUNDARY EXIST G ROW BOUNDARY PROPOSED GRADE AT SEC TION LINE \ EXISTING GRADE AT J SECTION LINE STA: 1 +55.75 EXISTING 12" STORM MAIN W.- -I IE:395.82 c�s2 T 1I 1 1 1.50' 1.50' i i 1 N GRAPHIC SCALE N 0 10 20 40 CY) O 1" = 20 FEET O N U LO 405 O O IN AREAS OF FILL, NEW ROADWAY SUBGRADE SHALL BE FILLED AND COMPACTED BEFORE EXCAVATION (V FOR INSTALLATION OF NEW WATER MAIN (TYP) 400 00 O T N - O O C) _ N STA: 1 +90.03 Q PROPOSED 6" ST RM _ J 395 STA: 2+21.28 1-10" POLYPIG STATION PER COR STD PLAN 300.7 1-22. ° BEND (MJ) / 1-CONC. TH UST BLOCK 22 LF 8" J STA: 2+16.34 5 LF 8" TA: 1+47.62 1-10' 6" TEE (MJxFL) 390 EXISTING 12" EWER MAIN 1- AT VALVE FLxM D.I. CL52 390 T.O.P: 389.29 1-CONC. HRUST BLOCK \ I FH ASS MBLY PER COR EX STING GRADE PROPOSED GRADE 387 AT SECTION LINE AT SECTION LINE 7 r7 �, 0 o cfl 00 o rno ao7 06Iq r10 o 0)0 WWCD 00 00 CDM M �`� M W W LL W LL WILL W LL 1+00 1+50 2+00 2+31.28 10 SITE SECTION 4 SCALE: H:1 "=20', V:1 "=2' W-433501 S-433501 R-433518 IN COMPLIANCE WITH CITY OF RENTON STANDARDS R DEVELOPMENT ENGINEERING ` • LHuynh 07/21/2025 '� WATER UTILITY WASTEWATER UTILITY U;%RW ABDOUL GAFOUR 07/25/2025 `� jstowell 07/28/2025 VERTICAL: NAVD 1988• SUNSET MEDICAL D I CAL OFFICE BUILDING DATE: FOR HORIZONTAL: NAD 1983/183/1991 CITY OF CONSTRUCTION FIELDBOOK: RENTON PAGE: ;R AHBL JOB #2230621.10 DATUM • DRAWING NO: Planning/Building/Public Works Dept. UTILITY PLAN C5.1 SHEET: 18 OF: 34 DocuSign Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3 Lid M M 1 N RECESSED Not to Scale LIFT POCKET FRAME 10-1/2" 14" �-- 12-3/4"� . 11" 12-1/4" CAST IRON RING AND DR )ABLE NOTES, 1 8" AND 6" CLEAN —OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC No 3698 (PRODUCT NO 00369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY 2 IN UNIMPROVED AREAS, POUR A 8" THICK, 3'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER 3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106 STD. PLAN - 403.1 PUBLIC WORKS 8" OR 6" CLEANOUT 7=Martin ne y 1` DEPARTMENT FOR SANITARY SEWER MAIN Pastucfia/26/2020 W49D DATE SEWER CLEANOUT NOT TO SCALE SANITARY SEWER NOTES & SPECIFICATIONS 1. ALL WORK AND WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT. AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN PUBLIC RIGHT OF WAY. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. 4. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. T. WAS, kr ,; kEClST sv S CONAL T A C O M A S P O K A N E 1 12 : 1 7. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 10. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 11. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON. 12. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. S E A T T L E T R I- C I T I E S 13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY. 16. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE OR MUST HAVE MINIMUM 2' DIAMETER CONCRETE RING POURED AT GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. S-433502 I*,- N CO O Nt N u �, N LID C) O O O N rr n KOC N O O O N Q D J Know what's below. Call before you dig. 07/21 /2025 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB L0 M M ti N DocuSlgn Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3 BEDDING MATERIAL FOR SANITARY SEWER PIPE (SEE NOTE 5) FOUNDATION LEVEL rW(SEE NOTE 7) LIMITS OF PIPE ZONE ON 0. D. Of PIPE Lot BEDDING FOR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS 5 PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3) OF THE STANDARD SPECIFICATIONS 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED 7 TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. STD. PLAN - 405 UBLIC WORKS PIPE BEDDING APP `�-- URI DEPARTMENT FOR SANITARY SEWERS Martin PastuCfta/26/202 rabic Wort, Addm �96E;449D DATE PIPE BEDDING FOR SANITARY SEWERS NOT TO SCALE Know what's below. Call before you T . WAS, kr ,; T A C O M A S E A T T L E rt S P O K A N E T R I- C I T I E S .c�sslc 69g �w� 2215 North 30th Street, Suite 300 Tacoma, WA 98403 ONAL E 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB dig. 07/21 /2025 DocuSlgn Envelope ID 345B681 D-914F-4F2D-AB59-7C 192D3B78A3 r---i-r----------- EX. SEWER MAIN I 1 1 I I I I PROPERTY LINE rr SPOOL I I I Z I (LENGTH AS NEEDED) i I i i 3'-0" MIN 6" SEWER STUB 1 I 1 ` ram• I I I I I I I I SEWER MAIN TEE X 6" TEE SIDEWALK i l z I I I I I J COUPLING TYP I I I I } I 0 I' r -r•--- J ------ --------- -ts L---J BEND AS REQUIRED EXISTING SANITARY SEWER MAIN r2 0% MI FUTURE 4" SIDE SEWER �0E-------------------- 3 2"x 4" STUD MARKING POST PAINTED 6" CAP/ WHITE WITH THE WORD "SEWER" STENCILED IN 3" HIGH BLACK LETTERS AND #6 WIRE WRAPPED AROUND THE STUD AND EXTENDED TO THE TOP OF THE STUD 6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR APPROVED EQUAL, SPECIFY "SEWER" ON LID), CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD CONCRETE PAD TO BE 8" IN DEPTH 6" SEWER STUB ` 6"X6"X6" WYE SEWER MAIN SIZE X 6" TEE PUTURE 4" SIDE SEWER FUTURE 6"x 4" REDUCER ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL), B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL) C PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUP-INGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F HDPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL NOTES. 1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT 2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER 3 SIDE SEWERS SHALL HAVE A MINIMUM 2 % SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR 4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 110 2 6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405 7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OP WASHINGTON SIDE SEWER STUB 4 STD. PLAN -406.1 APP SVk��9 nad by i PUBLIC WORKS INSTALLATION R] DEPARTMENT Martin PastuchW26/202 (SEWER MAIN TO PROPERTY LINE) 8H8.k33FD985449J— Pubic Works Admmistratm DATE SIDE SEWER STUB INSTALLATION NOT TO SCALE 1 12: DocuSlgn Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3 LENGTH(FT) w 0 d 50 100 Uj 150 200 Q 250 0 300 Z 350 00 400 450 LENGTH(FT) a 0 :L 50 100 150 Li 200 d 250 0 300 Z 350 400 450 LENGTH(FT) _`' 0 0- 50 of 100 Li w 150 200 a 0 250 Z 300 350 400 450 LENGTH(FT) ``I 0 a 50 Of 100 w u 150 < Q 200 0 250 Z 300 350 400 450 6 IN DIAMETER PIPE 0 50 1 100 150 200 250 300 350 400 450 1 500 0 80 160 236 316 396 476 556 632 680 680 140 220 300 380 456 536 616 696 712 708 708 280 360 440 520 600 676 748 744 7361 732 728 424 500 580 660 740 780 772 764 756 748 744 564 644 720 800 808 796 788 780 772 764 760 704 784 856 836 820 808 800 792 784 776 772 844 880 860 844 832 820 808 800 792 788 780 908 884 868 852 840 828 820 808 804 796 788 908 888 872 856 844 836 824 816 808 804 796 908 888 876 860 852 840 832 824 816 808 804 TIME (SECONDS) 6 IN DIAMETER PIPE 0 50 100 150 1 200 250 300 350 1 400 450 500 0 80 160 236 316 396 476 556 632 680 680 220 300 380 456 536 616 696 768 760 752 744 440 520 600 676 756 836 840 828 812 804 792 660 740 820 896 932 908 888 868 856 840 832 880 960 1028 992 964 940 920 900 888 872 860 1100 1084 1044 1012 988 964 944 928 912 900 888 1132 1092 1056 1028 1004 984 964 948 932 920 908 1132 1096 1068 1040 1016 996 980 964 948 936 924 1132 1100 1076 11052 1028 1008 992 976 964 952 940 1132 1104 1080 11056 1036 1020 1004 988 976 964 952 TIME (SECONDS) 6 IN DIAMETER PIPE 0 50 100 150 200 250 300 350 400 450 500 0 80 160 236 316 396 476 556 632 680 680 316 396 476 556 632 712 832 816 804 804 792 632 712 792 872 952 984 952 928 908 888 876 952 1028 1108 1132 1088 1052 1020 992 972 952 936 1268 1284 1224 1176 1132 1100 1068 1044 1020 1000 984 1360 1300 1248 1204 1164 1132 1104 1080 1056 1036 1020 1360 1308 1264 1224 1192 1160 1132 1108 1088 1068 1052 1360 1316 1276 1240 1208 1180 1156 1132 1112 1096 1076 1360 1320 1284 1252 1224 1200 1176 1152 1132 1116 1100 1360 1324 12.92 1264 1236 1212 1192 1168 1152 1132 1116 TIME (SECONDS) 6 IN DIAMETER PIPE 0 50 100 150 200 250 300 350 400 450 500 0 80 160 236 316 396 476 556 632 680 680 496 576 652 732 812 892 972 948 924 900 884 988 1068 1148 1228 1248 1192 1144 1104 1072 1044 1020 1484 1564 1484 1408 1344 1292 1248 1208 1172 1144 1116 1700 1608 1532 1464 1408 1360 1316 1280 1248 1216 1 1192 1700 1624 1560 1504 1452 1408 1368 1332 1304 1272 1248 1700 1636 1580 1532 1484 1444 1408 1376 1344 1316 1292 1700 1644 1596 1552 15'2 1472 1440 1408 1380 1352 1328 1700 1652 1608 1568 1532 1496 1464 1436 1408 1384 1360 1700 11656 1 1616 1580 11548 1516 1484 1460 1432 1408 1388 TIME (SECONDS) PROCEDURE SLOWLY PRESSURIZE THE PIPE TO 4 0 P S I G ALL SEWER PIPE SHALL MEET A MINIMUM AIR ALLOW 2 MINUTES FOR STABILIZATION, ADDING PRESSURE TEST OF 4 0 P S I G FOR 5 MINUTES AIR AS REQUIRED TO STABILIZE THE PRESSURE WITH NO LOSS OF PRESSURE IF THERE IS A LOSS AT 4 0 P S.I.G CF PRESSURE, THEN THE TIME OF THE DROP FROM 3 5 P S I G TO 2 5 P S I G SHALL NOT BE LESS THAN THE TIME SHOWN ON THE ABOVE TABLES AIR TEST TABLE APPI�85 ignodby PLAN - 410 r� PUBLIC WORKS LOW PRESSURE) DEPARTMENT Martin Pastuctt426/2020 FOR SANITARY SEWERS(*w"86&161FD98B449L) r ubbc Works Admmistrato DATE AIR TEST TABLE FOR SEWERS NOT TO SCALE 1 12 : S-433503 N C.fl O O N u �, N LO C) O i N KOC N C) C) O N Q D J