Loading...
HomeMy WebLinkAboutT-433502Co co It I 0 w coNcR o FIFA O ,N FRT + CD iNcgs4 N\ m 0100 3+00 r---� - D WATER D - D - I WATER MANHOLE EXISTING 12" GV I 4 IO I N63� - 595.07 ASPHALT 1 1 1 4 3 I I 1 5+00 n NE SUNSET BLVD 44 � ASPHALT r-(3) X� I 1 3 --S ----S -- - - i - /D--- S303.5 LF--- -- _�-� - -_ - - - - - -- - SID.EVV,ALK, PV' S S S TV °. v a 24' f7/ o i WORKMAN ARLENE M. 0323059055 / l / PROPOSED MEDICAL OFFICE SHELL LUMINAIRE 1 AND 3 SHALL BE PER COR STD 1 17.2 5,200 SF FOOTPRINT WITH 44W LED FIXTURE, 4-FT ARM, 20-FT CLEARANCE, NO FLOWER BASKET AND FACING SIDEWALK. LUMINAIRE 2 SHALL BE PER COR STD 1 1 7. 1 WITH DUAL FIXTURES: WITH ONE AT 35-FT CLEARANCE FACING STREET, 8-FT ARM AND 1 1 OW FIXTURE; AND LOWER FIXTURE WITH 20-FT CLEARANCE, FACING SIDEWALK, 4-FT ARM AND 44W FIXTURE. LUMINAIRE POLE SCHEDULE LUMINAIRE RENTON POLE POLE MOUNTING ARM STATION REFERENCE STATION LATITUDE ** LONGITUDE ** WATTAGE COMMENTS POLE NO. NO. OFFSET HEIGHT LENGTH O9 NE SUNSET BLVD. 4+28.61 33AFT RT 20.0' 4.0' 44W O2 NE SUNSET BLVD. 5+01.56 33AFT RT 40.0' 4.0' 44W O3 NE SUNSET BLVD. 5+60.61 33AFT RT 20.0' 4.0' 44W CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE MANAGER ERIC CUTSHALL, 425-430-7423 FOR POLE NUMBERS TO BE INCLUDED ON POLES. CONTRACTOR SHALL DETERMINE FINAL COORDINATES FOR RECORD DRAWINGS. WIRING SCHEDULE RACEWAY KEYNOTE NO. CONDUCTOR COMMENTS CONDUIT SIZE ZL 2" SCH80 2 - #8 ALL CONDUIT SHALL BE PVC AND SHALL CONTAIN A GROUND WIRE EQUAL IN SIZE TO THE LARGEST CONDUCTOR (MINIMUM NO. 8) UNLESS OTHERWISE NOTED. Know what's below. Call before you dig. �0.� kEGISTV w �SSIONAL 07/21 /2025 T A C O M A S E A T T L E S P O K A N E T R I- C I T I E S 2215 North 30th Street, Suite 300 Tacoma, WA 98403 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB S a a CONSTRUCTION NOTES N BENCHMARK DATUM VERTICAL DATUM = NORTH AMERICAN VERTICAL DATUM NAVD 88 (CITY OF RENTON) CITY OF RENTON SURVEY CONTROL POINT 2189 BASE: CITY OF RENTON CONTROL POINT #1845 FOUND MONUMENT INCASED AT STREET INTERSECTION OF 148TH AVENUE SOUTHEAST AND SOUTHEAST 112TH STREET. KING COUNTY SURVEY CONTROL POINT NO. 3725. ELEVATION: 467.77 FEET o N SITE NO. 1 + SET MAG NAIL IN SIDEWALK, 3' SOUTH OF FACE LO _ OF CURB ON SOUTH SIDE OF SUNSET BLVD. AT CENTER OF DRIVEWAY w ELEVATION: 400.60' 6+00 14+00 14 23 4 N63° 57' 27"E - �� SITE N0.2 N 828.07 SET PK NAIL IN ASPHALT, 8.8' NORTHEAST OF 1 LIGHT STANDARD, 27' NORTHEAST OF SOUTH 3 oN FOB END OF 6' CYCLONE FENCE. 1 w OON R //Vv ELEVATION: 396.77 Mv 2- - - - - � /Nc�s o �FNFR�I N[�TFS OINSTALL DOME STYLE LED 44W FIXTURE ON POLE PER COR STD PLAN 117.1, 117.2 AND 117.3. OCOORDINATE WITH CITY INSPECTOR FOR CONNECTION TO ELECTRICAL SERVICE. (VERIFY SERVICE HAS CAPACITY) OINSTALL LUMINAIRE AND JUNCTION BOX CONCRETE PAD. O4 INSTALL TYPE 1 JUNCTION BOX GRAPHIC SCALE 0 10 20 40 1" = 20 FEET 1. ALL WORK SHALL BE IN ACCORDANCE WITH RENTON STANDARD SPECIFICATIONS, RENTON STANDARD PLANS, AND THE CONTRACT, UNLESS OTHERWISE NOTED. A COPY OF THESE DOCUMENTS SHALL BE ON SITE DURING CONSTRUCTION. 2. A COPY OF THE APPROVED PLAN SHALL BE ON SITE DURING CONSTRUCTION. 3. ALL PERMITS REQUIRED FOR WORK WITHIN THE PUBLIC RIGHT OF WAY MUST BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. THE LOCATION OF EXISTING FEATURES AND UTILITIES SHOWN WITHIN THESE PLANS ARE APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCING LIGHTING WORK. NOT ALL EXISTING FEATURES AND UTILITIES MAY BE SHOWN. 5. LUMINAIRE WIRING SHALL BE PER THIS PLAN AND CITY OF RENTON STANDARD PLAN 119. 6. STREET LIGHT POLES SHALL BE NUMBERED PER CITY OF RENTON STANDARD PLAN 121. COORDINATE WITH THE CITY OF RENTON FOR NUMBERING. 7. FUSING AND/OR SPLICING OF LUMINAIRE WIRING SHALL BE PER CITY OF RENTON STANDARD PLAN J013. 8. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I.E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 9. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 10. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 11. LUMINAIRE AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 12. ALL ILLUMINATION SYSTEM ARE SUBJECT TO INSPECTION BY CITY OF RENTON TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE REPRESENTATIVE. 13. CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL (425) 430-7423 FOR STREET LIGHTING INSPECTION PRIOR TO ENERGIZING. 14. THE CONTRACTOR SHALL SUBMIT, FOR REVIEW BY THE ENGINEER, DESIGNS FOR THE LUMINAIRE POLE FOUNDATIONS THAT BEAR THE SEAL AND SIGNATURE OF A VALID LICENSED WASHINGTON STATE PROFESSIONAL ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY STRUCTURAL AND/OR GEOTECHNICAL ANALYSIS THAT MAY BE NEEDED TO DETERMINE THE NECESSARY FOUNDATION DEPTHS FOR THE NEIGHBORHOOD STREET PEDESTRIAN LUMINAIRE POLES, IN ACCORDANCE WITH CITY OF RENTON STANDARD PLAN 116.1. A GEOTECHNICAL ENGINEER SHALL BE PRESENT AT THE TIME OF BORING OF THE FOUNDATION TO VERIFY SOIL CONDITIONS. T-433501 r\ N co CO O O Nt N U �, O 0 I N V% O O O I N Q D J