Loading...
HomeMy WebLinkAboutR-392406N 00 M I I 0 LU 0 ro 0 00 0 0 N 0 CL 0 0 0 a 0 0 V) r 0 m 0 0 N O (n N r i c 0 i c w U d t 0 r N c 0 m 0 L coY Y 0 N I i 0 O co0 I U CL i X w a z J U_ A PORTION OF SECTION 10, TOWNSHIP 23 N., RANGE 05 E., W.M. 5 2.5 0 5 SCALE: 1 " = 5' CHELAN AVE NE . . . . . . . . . . . 5 2.5 . 0 5 (RESIDENTIAL ACCESS ROADWAY) CHELAN AVE NE : SCALE: 1° = 5' (RESIDENTIAL LIMITED ACCESS ROADWAY) ----------- - - - - - - -- - - - - - - - - - - - - - - - - - - - - - FL: 432.51 FL: 432.56 FL: 432.67 FL: 432.73 . . . . . . TBC: 433.01 TBC: 432.73 TBC: 432.84 TBC: 433.23 34.72 FL: 434.84 PROPOSED v 8' PLANTER 0 \ Qo SW: 435.38 1"- SW: 435.45 N5OPROPOSED5'SIDEWALKSW: 435.53 SW: 435.46 ABBREVIATION KEY SW: FINISHED GRADE ELEVATION @ TOP OF SIDEWALK FL: FINISHED GRADE ELEVATION @ FLOWLINE OF CURB TBC: FINISHED GRADE ELEVATION @ TOP BACK OF CURB RAMP #1 DETAIL SCALE: 1 "=5' d0 SW: 433.14 d0 M 47' 35' 12' 1 12' DEDICATION U U I PER DEED REC # O oI 20050823000001 W I oil ail 21.5' 13.5'- I lr BOUN SHORT PLAT 5'± I I I I (ON-SITE GRADING) 12'± EXISTING PAVEMENT I I VARIES 15.8'± EXISTING PAVEMENT I I 4 8 M PLANTER MAX 27.8'± PAVED ROADWAY �* 1, 5' SIDEWALK PER CITY OF RENTON ill 4.5' STD. PLAN 102 (TYP) WALK EXISTING � I I I ROAD CROWN @ ROW CIL 2%± PROPOSED 3' SAWCUT COMPACT SUBGRADE TO ACHIEVE 95% OF MAXIMUM DENSITY STANDARD PROCTOR 1.5% (MIN.) 1" X1.5% PROPOSED CURB & GUTTER (PER COR DETAIL 101) .4" HMA CL z" (PG 64-22) (MIN.) 6" CSTC CHELAN AVE NE TYPICAL ROAD SECTION (47' ROW) SCALE: N.T.S. (STA 1+99.39 TO STA 2+56.04) 12'-15' GRAVEL ACCESS ROAD 71� SLOP4"CRUSHED oE VARIES SURFACING TOP �1E (12% MAX.) _ COURSE (CSTC) 6" QUARRY SPALLS GEOTEXTILE FABRIC TYPICAL MAINTENANCE ACCESS ROAD SECTION SCALE: NTS =9 /1\ I ` 1 S W: 433.1 MA -d0 SW: 433.29 DO 434................................................................ ABBREVIATION KEY SW: FINISHED GRADE ELEVATION @ TOP OF SIDEWALK FL: FINISHED GRADE ELEVATION @ FLOWLINE OF CURB TBC: FINISHED GRADE ELEVATION @ TOP BACK OF CURB DRI VEWA Y DETAIL SCALE: 1 "=5' O U O W � W � U CLCL0 O 00 CLI a 23.5' RIGHT OF WAY DEDICATION 12' 10' 10' PLANTER 2 20' PAVED ROADWAY 5' SIDEWALK PER (MIN.) CITY OF RENTON STD. PLAN 102 (TYP) 1. 5% (MIN.) BOUN SHORT PLAT (ON-SITE GRADING) 201- ,1.5% TIE IN TO EXISTING GRADE @ 2:1 (MAX.) PROPOSED CURB & GUTTER (PER COR DETAIL 101) �4"HMA CL z" (PG 64-22) (MIN.) 6" CSTC COMPACT SUBGRADE TO ACHIEVE 95% OF MAXIMUM DENSITY STANDARD PROCTOR CHELAN AVE NE TYPICAL ROAD SECTION (35' ROW) SCALE: N.T.S. (STA 3+27.79 TO STA 4+04.20) SURVEY DATUM VERTICAL DATUM: HORIZONTAL BASIS OF BEARING: NAVD88 THE MONUMENTED CENTERLINE OF NE 10TH STREET BETWEEN CHELAN AVENUE NE AND DUVALL AVE NE PER BENCHMARK: CITY OF RENTON SHORT PLAT RECORDED UNDER CITY OF RENTON BENCHMARK #RENT159 RECORDING NUMBER 20120110900001 BRASS DISK IN CONCRETE RECESSED 0.6' BELOW THE TOP OF MONUMENT CASE AND COVER IN THE CENTER OF THE N 88030'08" W INTERSECTION AT NE 12TH STAND UNION AVE NE ELEVATION=415.961 EQUIPMENT USED: TOPCON PS 103A TOTAL STATION. STANDARD FIELD TRAVERSE METHODS FOR CONTROL AND STAKING. 4/25/18 NO. U 16' ROW DEDICATION 2' 6' 6' 2' 12' PAVED ROADWAY /b 221., i2% i20/ COMPACT SUBGRADE TO 4" HMA CL z" ACHIEVE 95% OF MAXIMUM (PG 64-22) (MIN.) DENSITY STANDARD PROCTOR 6" CSTC CHELAN PLACE NE TYPICAL ROAD SECTION (LOOKING NORTH) SCALE: N.T.S. SOURCE: CITY OF RENTON AMENDMENTS TO THE KING CO SWDM, REFERENCE 7-B 1. THESE NOTES SHALL APPEAR ON PROJECTS FOR THE SURFACE WATER UTILITY. 2. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD BETWEEN THE CITY OF RENTON PLAN REVIEW SECTION AND THE APPLICANT. 3. ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE RENTON MUNICIPAL CODE (RMC), THE LATEST EDITION OF THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE PROFESSIONAL CIVIL ENGINEER TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THIS PLANS, ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4, APPROVAL OF THIS ROAD, GRADING, PARKING AND DRAINAGE PLAN DOES NOT CONSTITUTE AN APPROVAL OF ANY OTHER CONSTRUCTION (E.G. DOMESTIC WATER CONVEYANCE, SEWER CONVEYANCE, GAS, ELECTRICAL. ETC.)THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN WITH THE CITY. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 5. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. GRADING ACTIVITIES (SITE ALTERATION) ARE LIMITED TO THE HOURS OF 7 A.M. TO 7 P.M. MONDAY THROUGH SATURDAY AND NO WORK ON SUNDAY IS ALLOWED, UNLESS OTHERWISE APPROVED WITH A WRITTEN DECISION BY THE CITY OF RENTON. 7. IT SHALL BE THE APPLICANT'S/CONTRACTOR'S RESPONSIBILITY TO OBTAIN ALL CONSTRUCTION EASEMENTS NECESSARY BEFORE INITIATING OFF-SITE WORK. EASEMENTS REQUIRE CITY REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. 8. FRANCHISED UTILITIES OR OTHER INSTALLATIONS THAT ARE NOT SHOWN ON THESE APPROVED PLANS SHALL NOT BE CONSTRUCTED UNLESS AN APPROVED SET OF PLANS THAT MEET ALL REQUIREMENTS OF CHAPTER 4 OF THE 2009 KING COUNTY SURFACE WATER DESIGN MANUAL ARE SUBMITTED TO THE CITY OF RENTON. 9. DATUM SHALL BE NAVD 88 UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 10. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWA TER FACILITIES MUST BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 11. ALL UTILITY TRENCHES AND ROADWAY SUBGRADE SHALL BE BACKFILLED AND COMPACTED TO 95 PERCENT DENSITY, STANDARD PROCTOR. 12. OPEN CUTTING OF EXISTING ROADWAYS FOR NON -FRANCHISED UTILITY OR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY OF RENTON AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY OF RENTON TRENCH RESTORATION UTILITY NOTE: THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. BEYLER CONSULTING ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. REVISION Know what's below. Call before you dig. SURVEYED: SCALE: BEYLER CONSULT. DESIGNED: 1 DTY/KRD DRAWN: DTY/KRD ONE INCH CHECKED: AT FULL SCALE DRB IF NOT ONE INCH BY DATE AP P R APPROVED: SCALE ACCORDINGLY DRB VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M U (n Q � . W � W U Un WI U. U U U Q Q Q 16' ACCT SS EASEMENT PROPOSED 2' 1 ASPHALT WEDGE 12' PAVED ROADWAY 4' U� 2' 0 VARIES i2 1/. VARIES 74" HMA CL z" (PG 64-22) (MIN.) 6" CSTC COMPACT SUBGRADE TO ACHIEVE 95010 OF MAXIMUM DENSITY STANDARD PROCTOR ACCESS EASEMENT TYPICAL ROAD SECTION SCALE: N.T.S. STANDARDS. 13. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON-SITE EROSION HAS PASSED. 14. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C", WITH THE EXCEPTION OF PVC PIPE. 16. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE. 17. ALL DRAINAGE STRUCTURES, SUCH AS CATCH BASINS AND MANHOLES SHALL HAVE SOLID LOCKING LIDS. ALL DRAINAGE STRUCTURES ASSOCIATED WITH A PERMANENT RETENTION/DETENTION FACILITY SHALL HAVE SOLID LOCKING LIDS. 18. BUILDING AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH RENTON MUNICIPAL CODE TABLE 4-2-11 OA SETBACKS LINES. 19. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 20. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY OF RENTON RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK 140 - 70% PASSING; 2 - 4 INCH ROCK/ 30 - 40% PASSING; AND LESS THAN 2 INCH ROCK/ 10 - 20% PASSING. 21. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. 22. DRAINAGE OUTLETS (STUB -OUTS) SHALL BE PROVIDED FOR EACH INDIVIDUAL LOT, EXCEPT FOR THOSE LOTS APPROVED FOR INFILTRATION BY THE CITY. STUB -OUTS SHALL CONFORM TO THE FOLLOWING: A. EACH OUTLET SHALL BE SUITABLY LOCATED AT THE LOWEST ELEVATION ON THE LOT, SO AS TO SERVICE ALL FUTURE ROOF DOWNSPOUTS AND FOOTING DRAINS, DRIVEWAYS, YARD DRAINS, AND ANY OTHER SURFACE OR SUBSURFACE DRAINS NECESSARY TO FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH OTHERWISE VIOLATE ANY STATE, FEDERAL. OR LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE, ORDER, OR STANDARD. RENDER THE LOTS SUITABLE FOR THEIR INTENDED USE. EACH OUTLET SHALL HAVE FREE-FLOWING, POSITIVE DRAINAGE TO AN APPROVED STORMWATER CONVEYANCE SYSTEM OR TO AN APPROVED OUTFALL LOCATION. B. OUTLETS ON EACH LOT SHALL BE LOCATED WITH A FIVE -FOOT -HIGH, 2" X 4" STAKE MARKED "STORM" OR "DRAIN". THE STUB -OUT SHALL EXTEND ABOVE SURFACE LEVEL, BE VISIBLE, AND BE SECURED TO THE STAKE. C. PIPE MATERIAL SHALL CONFORM TO UNDERDRAIN SPECIFICATIONS DESCRIBED IN CHAPTER 4 OF THE 2009 KING COUNTY SURFACE WATER DESIGN MANUAL AND, IF NON-METALLIC, THE PIPE SHALL BE PLACED IN A TRENCH WITH A TRACING WIRE ABOVE OR OTHER ACCEPTABLE DETECTION. D. PRIVATE DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO CONVEY FLOWS THROUGH INDIVIDUAL LOTS. E. THE APPLICANT/CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL STUBOUT CONVEYANCE LINES WITH RESPECT TO OTHER UTILITIES (E.G. POWER, GAS, TELEPHONE, TELEVISION). F. ALL INDIVIDUAL STUB -OUTS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE LOT HOME OWNER. G. STORM DRAINAGE PIPE SYSTEMS SHALL NOT PENETRATE BUILDING FOUNDATIONS, EXCEPT FOR SUMP PUMP DISCHARGE LINES USED TO DRAIN CRAWL SPACES, PROVIDED THE SUMP PUMP SYSTEM INCLUDES BACKFLOW PREVENTION OR A CHECK VALVE. 23. ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE MUST DEMONSTRATE ONE OF THE FOLLOWING: THE EXISTING DUFF LAYER SHALL BE STAGED AND REDISTRIBUTED TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL, OR; AMENDED SOIL SHALL BE ADDED TO MAINTAIN THE MOISTURE CAPACITY. 24. PROOF OF LIABILITY INSURANCE SHALL BE SUBMITTED TO THE CITY PRIOR TO CONSTRUCTION PERMIT ISSUANCE. 25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 26. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. 27. PROJECT LOCATED WITHIN THE AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT #6 OF THE SURFACE WATER DESIGN MANUAL AND AQUIFER PROTECTION REGULATIONS (RMC 4-3-050). IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3)B, IT SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKERS SAFETY AND BEYLER CONSULTING ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17 RCW. 1 H N T I T Q J c R-392406 IN COMPLIANCE WITH CITY OF RENTON STANDARDS BEYLER DEVELOPMENT ENGINEERING ' SURFACE WATER UTILITY CONSULTING `~� CONTACT (Fitz -James 04/30/2018 krevans 05/04/2018 phone: 253-301-4157 OFFICE Q fax: 253-336-3950 5920 100TH ST SW, STE 25 beylerconsulting.com Lakewood, WA 98499 DATE: O CITY OF BOUN SHORT PLAT 12/14/2017 = RENTON CONSTRUCTION PLANS PAGE:FIELDOOK:NA ANA LU16-000124 SHPL-A U16-006297 PAGE: z • � f 7 DRAWING N0: Planning/Building/Public Works Dept. GRADING/PAVING/STORMWATER PLAN & PROFILE C6 DUVALL AVE NE SHEET: 6 OF: 19 CO 6' 12' 6' 0. 60101 PROPOSED co 8'PLANTER X15 SW: 433.31 0.6% 6. /o SW: 43 .07 vi 010 p5 0 Fo PROPOSED 5' SIDEWALK d0 SW: 433.14 d0 M 47' 35' 12' 1 12' DEDICATION U U I PER DEED REC # O oI 20050823000001 W I oil ail 21.5' 13.5'- I lr BOUN SHORT PLAT 5'± I I I I (ON-SITE GRADING) 12'± EXISTING PAVEMENT I I VARIES 15.8'± EXISTING PAVEMENT I I 4 8 M PLANTER MAX 27.8'± PAVED ROADWAY �* 1, 5' SIDEWALK PER CITY OF RENTON ill 4.5' STD. PLAN 102 (TYP) WALK EXISTING � I I I ROAD CROWN @ ROW CIL 2%± PROPOSED 3' SAWCUT COMPACT SUBGRADE TO ACHIEVE 95% OF MAXIMUM DENSITY STANDARD PROCTOR 1.5% (MIN.) 1" X1.5% PROPOSED CURB & GUTTER (PER COR DETAIL 101) .4" HMA CL z" (PG 64-22) (MIN.) 6" CSTC CHELAN AVE NE TYPICAL ROAD SECTION (47' ROW) SCALE: N.T.S. (STA 1+99.39 TO STA 2+56.04) 12'-15' GRAVEL ACCESS ROAD 71� SLOP4"CRUSHED oE VARIES SURFACING TOP �1E (12% MAX.) _ COURSE (CSTC) 6" QUARRY SPALLS GEOTEXTILE FABRIC TYPICAL MAINTENANCE ACCESS ROAD SECTION SCALE: NTS =9 /1\ I ` 1 S W: 433.1 MA -d0 SW: 433.29 DO 434................................................................ ABBREVIATION KEY SW: FINISHED GRADE ELEVATION @ TOP OF SIDEWALK FL: FINISHED GRADE ELEVATION @ FLOWLINE OF CURB TBC: FINISHED GRADE ELEVATION @ TOP BACK OF CURB DRI VEWA Y DETAIL SCALE: 1 "=5' O U O W � W � U CLCL0 O 00 CLI a 23.5' RIGHT OF WAY DEDICATION 12' 10' 10' PLANTER 2 20' PAVED ROADWAY 5' SIDEWALK PER (MIN.) CITY OF RENTON STD. PLAN 102 (TYP) 1. 5% (MIN.) BOUN SHORT PLAT (ON-SITE GRADING) 201- ,1.5% TIE IN TO EXISTING GRADE @ 2:1 (MAX.) PROPOSED CURB & GUTTER (PER COR DETAIL 101) �4"HMA CL z" (PG 64-22) (MIN.) 6" CSTC COMPACT SUBGRADE TO ACHIEVE 95% OF MAXIMUM DENSITY STANDARD PROCTOR CHELAN AVE NE TYPICAL ROAD SECTION (35' ROW) SCALE: N.T.S. (STA 3+27.79 TO STA 4+04.20) SURVEY DATUM VERTICAL DATUM: HORIZONTAL BASIS OF BEARING: NAVD88 THE MONUMENTED CENTERLINE OF NE 10TH STREET BETWEEN CHELAN AVENUE NE AND DUVALL AVE NE PER BENCHMARK: CITY OF RENTON SHORT PLAT RECORDED UNDER CITY OF RENTON BENCHMARK #RENT159 RECORDING NUMBER 20120110900001 BRASS DISK IN CONCRETE RECESSED 0.6' BELOW THE TOP OF MONUMENT CASE AND COVER IN THE CENTER OF THE N 88030'08" W INTERSECTION AT NE 12TH STAND UNION AVE NE ELEVATION=415.961 EQUIPMENT USED: TOPCON PS 103A TOTAL STATION. STANDARD FIELD TRAVERSE METHODS FOR CONTROL AND STAKING. 4/25/18 NO. U 16' ROW DEDICATION 2' 6' 6' 2' 12' PAVED ROADWAY /b 221., i2% i20/ COMPACT SUBGRADE TO 4" HMA CL z" ACHIEVE 95% OF MAXIMUM (PG 64-22) (MIN.) DENSITY STANDARD PROCTOR 6" CSTC CHELAN PLACE NE TYPICAL ROAD SECTION (LOOKING NORTH) SCALE: N.T.S. SOURCE: CITY OF RENTON AMENDMENTS TO THE KING CO SWDM, REFERENCE 7-B 1. THESE NOTES SHALL APPEAR ON PROJECTS FOR THE SURFACE WATER UTILITY. 2. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD BETWEEN THE CITY OF RENTON PLAN REVIEW SECTION AND THE APPLICANT. 3. ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE RENTON MUNICIPAL CODE (RMC), THE LATEST EDITION OF THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE PROFESSIONAL CIVIL ENGINEER TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THIS PLANS, ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4, APPROVAL OF THIS ROAD, GRADING, PARKING AND DRAINAGE PLAN DOES NOT CONSTITUTE AN APPROVAL OF ANY OTHER CONSTRUCTION (E.G. DOMESTIC WATER CONVEYANCE, SEWER CONVEYANCE, GAS, ELECTRICAL. ETC.)THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN WITH THE CITY. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 5. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. GRADING ACTIVITIES (SITE ALTERATION) ARE LIMITED TO THE HOURS OF 7 A.M. TO 7 P.M. MONDAY THROUGH SATURDAY AND NO WORK ON SUNDAY IS ALLOWED, UNLESS OTHERWISE APPROVED WITH A WRITTEN DECISION BY THE CITY OF RENTON. 7. IT SHALL BE THE APPLICANT'S/CONTRACTOR'S RESPONSIBILITY TO OBTAIN ALL CONSTRUCTION EASEMENTS NECESSARY BEFORE INITIATING OFF-SITE WORK. EASEMENTS REQUIRE CITY REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. 8. FRANCHISED UTILITIES OR OTHER INSTALLATIONS THAT ARE NOT SHOWN ON THESE APPROVED PLANS SHALL NOT BE CONSTRUCTED UNLESS AN APPROVED SET OF PLANS THAT MEET ALL REQUIREMENTS OF CHAPTER 4 OF THE 2009 KING COUNTY SURFACE WATER DESIGN MANUAL ARE SUBMITTED TO THE CITY OF RENTON. 9. DATUM SHALL BE NAVD 88 UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 10. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWA TER FACILITIES MUST BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 11. ALL UTILITY TRENCHES AND ROADWAY SUBGRADE SHALL BE BACKFILLED AND COMPACTED TO 95 PERCENT DENSITY, STANDARD PROCTOR. 12. OPEN CUTTING OF EXISTING ROADWAYS FOR NON -FRANCHISED UTILITY OR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY OF RENTON AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY OF RENTON TRENCH RESTORATION UTILITY NOTE: THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. BEYLER CONSULTING ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. REVISION Know what's below. Call before you dig. SURVEYED: SCALE: BEYLER CONSULT. DESIGNED: 1 DTY/KRD DRAWN: DTY/KRD ONE INCH CHECKED: AT FULL SCALE DRB IF NOT ONE INCH BY DATE AP P R APPROVED: SCALE ACCORDINGLY DRB VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M U (n Q � . W � W U Un WI U. U U U Q Q Q 16' ACCT SS EASEMENT PROPOSED 2' 1 ASPHALT WEDGE 12' PAVED ROADWAY 4' U� 2' 0 VARIES i2 1/. VARIES 74" HMA CL z" (PG 64-22) (MIN.) 6" CSTC COMPACT SUBGRADE TO ACHIEVE 95010 OF MAXIMUM DENSITY STANDARD PROCTOR ACCESS EASEMENT TYPICAL ROAD SECTION SCALE: N.T.S. STANDARDS. 13. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON-SITE EROSION HAS PASSED. 14. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C", WITH THE EXCEPTION OF PVC PIPE. 16. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE. 17. ALL DRAINAGE STRUCTURES, SUCH AS CATCH BASINS AND MANHOLES SHALL HAVE SOLID LOCKING LIDS. ALL DRAINAGE STRUCTURES ASSOCIATED WITH A PERMANENT RETENTION/DETENTION FACILITY SHALL HAVE SOLID LOCKING LIDS. 18. BUILDING AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH RENTON MUNICIPAL CODE TABLE 4-2-11 OA SETBACKS LINES. 19. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 20. ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY OF RENTON RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK 140 - 70% PASSING; 2 - 4 INCH ROCK/ 30 - 40% PASSING; AND LESS THAN 2 INCH ROCK/ 10 - 20% PASSING. 21. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. 22. DRAINAGE OUTLETS (STUB -OUTS) SHALL BE PROVIDED FOR EACH INDIVIDUAL LOT, EXCEPT FOR THOSE LOTS APPROVED FOR INFILTRATION BY THE CITY. STUB -OUTS SHALL CONFORM TO THE FOLLOWING: A. EACH OUTLET SHALL BE SUITABLY LOCATED AT THE LOWEST ELEVATION ON THE LOT, SO AS TO SERVICE ALL FUTURE ROOF DOWNSPOUTS AND FOOTING DRAINS, DRIVEWAYS, YARD DRAINS, AND ANY OTHER SURFACE OR SUBSURFACE DRAINS NECESSARY TO FILL MATERIAL SHALL NOT CONTAIN PETROLEUM PRODUCTS, OR SUBSTANCES WHICH ARE HAZARDOUS, DANGEROUS, TOXIC, OR WHICH OTHERWISE VIOLATE ANY STATE, FEDERAL. OR LOCAL LAW, ORDINANCE, CODE, REGULATION, RULE, ORDER, OR STANDARD. RENDER THE LOTS SUITABLE FOR THEIR INTENDED USE. EACH OUTLET SHALL HAVE FREE-FLOWING, POSITIVE DRAINAGE TO AN APPROVED STORMWATER CONVEYANCE SYSTEM OR TO AN APPROVED OUTFALL LOCATION. B. OUTLETS ON EACH LOT SHALL BE LOCATED WITH A FIVE -FOOT -HIGH, 2" X 4" STAKE MARKED "STORM" OR "DRAIN". THE STUB -OUT SHALL EXTEND ABOVE SURFACE LEVEL, BE VISIBLE, AND BE SECURED TO THE STAKE. C. PIPE MATERIAL SHALL CONFORM TO UNDERDRAIN SPECIFICATIONS DESCRIBED IN CHAPTER 4 OF THE 2009 KING COUNTY SURFACE WATER DESIGN MANUAL AND, IF NON-METALLIC, THE PIPE SHALL BE PLACED IN A TRENCH WITH A TRACING WIRE ABOVE OR OTHER ACCEPTABLE DETECTION. D. PRIVATE DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO CONVEY FLOWS THROUGH INDIVIDUAL LOTS. E. THE APPLICANT/CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL STUBOUT CONVEYANCE LINES WITH RESPECT TO OTHER UTILITIES (E.G. POWER, GAS, TELEPHONE, TELEVISION). F. ALL INDIVIDUAL STUB -OUTS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE LOT HOME OWNER. G. STORM DRAINAGE PIPE SYSTEMS SHALL NOT PENETRATE BUILDING FOUNDATIONS, EXCEPT FOR SUMP PUMP DISCHARGE LINES USED TO DRAIN CRAWL SPACES, PROVIDED THE SUMP PUMP SYSTEM INCLUDES BACKFLOW PREVENTION OR A CHECK VALVE. 23. ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE MUST DEMONSTRATE ONE OF THE FOLLOWING: THE EXISTING DUFF LAYER SHALL BE STAGED AND REDISTRIBUTED TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL, OR; AMENDED SOIL SHALL BE ADDED TO MAINTAIN THE MOISTURE CAPACITY. 24. PROOF OF LIABILITY INSURANCE SHALL BE SUBMITTED TO THE CITY PRIOR TO CONSTRUCTION PERMIT ISSUANCE. 25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 26. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. 27. PROJECT LOCATED WITHIN THE AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT #6 OF THE SURFACE WATER DESIGN MANUAL AND AQUIFER PROTECTION REGULATIONS (RMC 4-3-050). IF WORKERS ENTER ANY TRENCH OR OTHER EXCAVATION FOUR OR MORE FEET IN DEPTH THAT DOES NOT MEET THE OPEN PIT REQUIREMENTS OF WSDOT SECTION 2-09.3(3)B, IT SHALL BE SHORED AND CRIBBED. THE CONTRACTOR ALONE SHALL BE RESPONSIBLE FOR WORKERS SAFETY AND BEYLER CONSULTING ASSUMES NO RESPONSIBILITY. ALL TRENCH SAFETY SYSTEMS SHALL MEET THE REQUIREMENTS OF THE WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT, CHAPTER 49.17 RCW. 1 H N T I T Q J c R-392406 IN COMPLIANCE WITH CITY OF RENTON STANDARDS BEYLER DEVELOPMENT ENGINEERING ' SURFACE WATER UTILITY CONSULTING `~� CONTACT (Fitz -James 04/30/2018 krevans 05/04/2018 phone: 253-301-4157 OFFICE Q fax: 253-336-3950 5920 100TH ST SW, STE 25 beylerconsulting.com Lakewood, WA 98499 DATE: O CITY OF BOUN SHORT PLAT 12/14/2017 = RENTON CONSTRUCTION PLANS PAGE:FIELDOOK:NA ANA LU16-000124 SHPL-A U16-006297 PAGE: z • � f 7 DRAWING N0: Planning/Building/Public Works Dept. GRADING/PAVING/STORMWATER PLAN & PROFILE C6 DUVALL AVE NE SHEET: 6 OF: 19 CO