HomeMy WebLinkAboutW-392402tN7 co T M N co 0 0 N a 0 a 0 a 0 0 r N 3 0 m m 0 N I m i a) 0 r i N 3 0 0 i w i 0 a 0 0 m m 0 L Y Y 0 0 N I 0 0 O 0 I 0 i U a� a` i X Lija z 20 10 0 20 40 SCALE: 1" = 20' EXISTING ROAD WEST OF CL - ESTIMATED EXISTING GRADE ABOVE EXISTING GRADE (NO EDGE OF ROW PROPOSED D.I.P. TOPOGRAPHIC INFORMATION) 44 PROPOSED FIRE HYDRANTASSEMBLY PER COR 310.1 EXISTING 12" RCP IE 435.4 (TO BE REMOVED)43 CONCRETE THRUST BLOCK PER COR 310.1 (TYP) CAST IRON VALVE BOX PER COR 310.1 43 5II 1 I L J APPROX. OF EX, 1 O DATE: 12/14/2017 POINT OF CONNECTION #3 1 MAIN (P STA 103+86.42, 25.00'R (DUVALL AVE NE) 16x8 TAPPING TEE (MJ X FL) 60f LF - 8" D. P. CL -52 W/ (1) 8" TAPPING VALVE (FL X MJ) EXISTING GRADE EXISTING EDGE OF ASPHALT PROPOSED GRADE @ PER C.O.R. DETAIL 300.1 DIRECTLY ABOVE W/ THRUST BLOCKING .....::::::::::::::i APPROX. LOCATION 8"x6" TEE (MJxFL) i U -)r\ OF EX. 16" WATER W/ (1) 6" GATE VALVE (FLxMJ K MAIN (PER W-2950) W/ PExPE DI SPOOL PIECE), 1 8" PLUG MJ W 36" (MIN.) ' W/ THRUST BLOCKING✓ 6400D. - -52 O 84 __j_U f -5� F-$.DLp-C �- 60f LF 8" I.P. CL INSTALL HYDRANT ASSEMBLY a PER COR 310.1 W 5.6' 8t LF - 6" STA 103+86.42 (COORDINATE FLANGE (PIPE CROSSING #6) CL -52 D.LP.:;; w ELEVATION WITH CITY PRIOR TO i ............:: INSTALLATION) w ::::: (SEE SHEET C11.0) W W W �I 0'1 1 1 ' "'........ NOTE: TEMPORARY BOLLARDS MAY BE REQUIRED TO PROTECT HYDRANT EXISTING 12" RCP 00 ti Ln rn DEPENDING ON TIMELINE OF (TO BE REMOVED, TEMPORARY w W V- v HYDRANT INSTALLATION AND CITY CONVEYANCE DITCH SHALL BE Nt ""` J DUVALL AVE NE PROJECT. IN LIEU OF RCP) . J ........... y.wwW w :....::::::.....:......::r..... DUVALL AVE NE FIRE HYDRANT PLAN SCALE: HORIZONTAL: 1" = 20' CENTER LINE OF 20 10 0 20 40 SCALE: 1" = 20' EXISTING ROAD WEST OF CL - ESTIMATED EXISTING GRADE ABOVE EXISTING GRADE (NO EDGE OF ROW PROPOSED D.I.P. TOPOGRAPHIC INFORMATION) 44 PROPOSED FIRE HYDRANTASSEMBLY PER COR 310.1 EXISTING 12" RCP IE 435.4 (TO BE REMOVED)43 CONCRETE THRUST BLOCK PER COR 310.1 (TYP) CAST IRON VALVE BOX PER COR 310.1 43 5II 1 2.4% 4o/o_ J APPROX. OF EX, 1 O DATE: 12/14/2017 1: 36" (MIN.) U) MAIN (P DRAWING NO: C13 II 60f LF - 8" D. P. CL -52 EXISTING GRADE PROPOSED GRADE @ DIRECTLY ABOVE RIGHT OF WAY PROPOSED 8" D.I.P. 0) U -)r\ K 36" (MIN.) 40 LOCATION 6" WATER ER W-2950) 35 0+90 30 DUVALL AVE NE FIRE HYDRANT PROFILE SCALE: HORIZONTAL: 1 " = 20' VERTICAL: 1" = 5' SOURCE: CITY OF RENTON AMENDMENTS TO THE KING CO SWDM, REFERENCE 7-B 1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AT (425) 430-7301. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATES CALL 48-HOUR LOCATORS 800-424-5555. 4. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AT THE PRE -CONSTRUCTION MEETING. 5. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6. ALL WATERMAIN PIPE IS TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C105/A21.5-93 STANDARDS. 7. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA CI 10/A21.10-87. CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104142114-90. IF FITTINGS ARE 3 TO 12 INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL IN ACCORDANCE WITH EITHER ANSI/AWWA C110 -A21.10-87 OR ANSI/AWWA C153/A21.53-94. THREE (3) INCH TO 12 INCH DIAMETER FITTINGS, WHICH HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS, SHALL BE IN ACCORDANCE WITH ANSI/AWWA CI 10/A21.10.87 OR A COMBINATION OF ANSI/AWWA C110/A21.10.87 AND ANSI/AWWA C153/A21.53-94 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE WITH ANSI/AWWA C153/A21.53-94 AND THAT PORTION OF THE FITTING WITH FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH AWWA C110/A21.10-87. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53.53 OF ANSI/AWWA SECTION 10-4.3 OF ANSI/AWWA CI 10/A21.10-87 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 8. GATE VALVES SHALL BE IRON BODY, BRONZED -MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND O-RING STUFFING BOX (AWWA C500) OR OF RESILIENT SEATED TYPE (AWWA C509). VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380 OR M & H. 9. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR COMPRESSION TYPE (OPENING AGAINST PRESSURE) CONFORMING TO AWWA C-502-85 WITH A 6 INCH MECHANICAL JOINT INLET AND A MAIN VALVE OPENING (M. V. O.) OF 5-1/4 INCH, TWO 2-1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD THREADS 7-1/2 THREADS PER INCH AND ONE 4 INCH PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH, 60 DEGREES V. THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND ROOT DIAMETER 4.6263. HYDRANTS SHALL HAVE A 1-1/4 INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT). 10. THE TWO 2-1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND PROPORTIONS AS THE HYDRANT STEM NUT. CAPS SHALL BE FITTED WITH SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST PRESSURES. 11. THE 4 INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4 INCH SEATTLE THREAD X 5 INCH STORZ. STORZ ADAPTER SHALL BE FORGED AND/OR EXTRUDED 6061-T6 ALUMINUM ALLOY, HARDCOAT ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET SCREWS 180 DEGREES APART. STORZ FACE TO BE METAL, NO GASKET TO WEATHER. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8 INCH, COATED, STAINLESS STEEL, AIRCRAFT CABLE. 12. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT NUMBER 43-655 SAFETY YELLOW OR APPROVED EQUAL. 13. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. 14. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAIL FOR FIRE HYDRANTS, LATEST REVISION. 15. ALL WATERMAINS 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATERMAIN 12 INCHES AND LARGER SHALL BE ATA MINIMUM OF 48 INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATERMAINS ARE TO BE LOWERED TO CLEAR. 16. ALL WATERMAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL, 2 LB/CU. FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY. 17. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 18. ALL WATERMAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY OF RENTON STANDARD PLANS & SPECIFICATIONS 7-11.3(11). THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 19. ALL WATERMAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METERED/INJECTED IN ACCORDANCE WITH SECTION 7-11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED ABOVE. 20. A PRE -CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. 21. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 22. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 23. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE CITY OF RENTON. 24. ALL CONNECTION TO EXISTING MAINS IS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS, WHICH MAY BE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE ON-SITE PRIOR TO CITY NOTIFICATIONS. 25. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS. A PORTION OF SECTION 10, TOWNSHIP 23 N., RANGE 05 E., W.M. 4/25/18 SEE SHEET C1.0 FOR INFORMATION REGARDING THE LOCATION OF THE HYDRANT AND WATER CROSSINGS. 26. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 27. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. 28. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES. OIL MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 29. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN 10 DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH. 30. FOR CITY PROJECTS SUCH AS TELEMETRY CONDUIT, THE PVC PIPE USED SHALL BE ALL CHEMICAL PROCESS LINES SHALL BE SCHEDULE 80 PVC PIPE. SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 PVC PIPE UNDER IMPROVED AREAS. UTILITY NOTE: THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. BEYLER CONSULTING ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. 1. ALL CONCRETE BLOCKING FOR HORIZONTAL BENDS, TEE, AND VERTICAL BENDS SHALL BE PER CITY OF RENTON STD. PLANS 330.2 AND 330.3. 2. WATER MAIN PIPES IN CHELAN PLACE NE (ALLEY) SHALL BE DUCTILE IRON CL -52 TYTON JOINT (PUSH -ON) PIPE WITH RESTRAINED HARNESS AT BELLS EQUAL TO MEGALUG SERIES 1700 OR ROMAGRIP 600 SERIES OR APPROVED EQUAL OR WATER MAIN PIPES SHALL BE MECHANICAL JOINT PIPES WITH RESTRAINED RETAINER GLANDS EQUAL TO MEGALUG 1100 SERIES OF ROMAGRIP OR APPROVED EQUAL. 3. ALL FITTINGS SHALL BE MECHANICAL JOINT WITH RESTRAINED RETAINER GLANDS AND WITH CONCRETE BLOCKING PER CITY OF RENTON STANDARD PLANS. 20 10 0 20 40 SCALE: 1" = 20' POINT OF CONNECTION #2 -c3u MLiuM /V1 M M STA 3+04.15, 4'38'R 8" - 90° D.I. BEND (MJ) E CHELAN AVE NE W/ THRUST BLOCKING--+' .•:' . ' E E E • •E F E E E E E E' 4� • E E E E E E•'' P E. •. E E E E E E E E E E E E E E - E E E E E E E E E E E E E E E E E E E E E E E E •E' E E E E E E E E E E E E E E E E E- E E E• • 'E' •' .�L E E E E E E E E• f, .E. • E E•' 'f . E• E E E E E -_1 F__ CHELAN AVE NE WATER PLAN SCALE: HORIZONTAL: 1" = 20' 8" - 900 D.I. BEND W/ THRUST BLOCKING M76 431 POINT OF CONNECTION #2 8" TAPPING TEE (MJ X FL) W/ (1) 8" TAPPING VALVE (FL X MJ) PER C.O.R. DETAIL 300.1 W/ THRUST BLOCKING 42: (SEE SHEET C14.0) VERTICAL DATUM: NAVD88 BENCHMARK: CITY OF RENTON BENCHMARK #RENT159 BRASS DISK IN CONCRETE RECESSED 0.6' BELOW THE TOP OF MONUMENT CASE AND COVER IN THE CENTER OF THE INTERSECTION AT NE 12TH ST AND UNION AVE NE ELEVATION=415.961 SURVEYED: SCALE: BEYLER CONSULT. DESIGNED: 1 "=20' DTY/KRD DRAWN: DTY/KRD ONE INCH CHECKED: AT FULL SCALE DRB IF NOT ONE INCH NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY DRB 421 `STA 4+04.35 7.00'L INSTALL TEMPORARY 8"x8" VERTICAL CROSS (MJxMJ) FOR REMOVAL OF POLYPIGS PER CITY OF RENTON STD. PLAN 300.6 AFTER COMPLETION OF POLYPIG CLEANING/DEBRIS REMOVAL INSTALL 1 - 8" D.I. CAP (MJ) W/ 2" TAP X 2" TEMPORARY BLOW -OFF ASSEMBLY PER C. 0. R. STANDARD DETAIL 340.2 (SEE SHEET C14.0) 4+24 - VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M TEMPORARY 2" GALVANZIED PIPE AND 2" GATE VALVE PER COR STANDARD PLAN 300.6 (SEE SHEET C14.0) 135 125 3+00 4+00 4+20 CHELAN AVE NE WATER PROFILE SCALE: HORIZONTAL: 1 " = 20' VERTICAL: 1" = 5' Know what's below. 0111 before you dig. HORIZONTAL BASIS OF BEARING: THE MONUMENTED CENTERLINE OF NE 10TH STREET BETWEEN CHELAN AVENUE NE AND DUVALL AVE NE PER CITY OF RENTON SHORT PLAT RECORDED UNDER RECORDING NUMBER 20120110900001 N 88030'08" W EQUIPMENT USED: TOPCON PS 103A TOTAL STATION. STANDARD FIELD TRAVERSE METHODS FOR CONTROL AND STAKING. v CITY OF RENTOR Planning/Building/Public Works Dept. CONCRETE THRUST BLOCKING PER COR STANDARD PLAN 300.6 (SEE SHEET C14.0) BEYLER CONSULTING CONTACT phone: 253-301-4157 OFFICE fax: 253-336-3950 5920 100TH ST SW, STE 25 beylerconsulting.com Lakewood, WA 98499 W-392402 IN COMPLIANCE WITH CITY OF RENTON STANDARDS EPMENT ENGINEERING WATER UTILITY + + [Abdoul Gafour 04/ 0/201 I- mes 04/30/2018 3 8 ' BOUN SHORT PLAT CONSTRUCTION PLANS LUA16-000124, SHPL-A, U16-006297 WATER PLAN & PROFILE DUVALL AVE NE _j EXISTING GRADE @ It It O DATE: 12/14/2017 1: FIELDBOOK: NA U) RIGHT OF WAY Z DRAWING NO: C13 SHEET: 1 OF:1 M CENTERLINE (TYP) PROPOSED GRADE @ RIGHT OF WAY CENTERLINE (TYP) 36" (MIN.) __j_U f -5� F-$.DLp-C �- APPROX 5.6' (PIPE CROSSING #6) i �I 0'1 N ti 141) Ln p rl 00 ti Ln rn r6 V- v Nt VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M TEMPORARY 2" GALVANZIED PIPE AND 2" GATE VALVE PER COR STANDARD PLAN 300.6 (SEE SHEET C14.0) 135 125 3+00 4+00 4+20 CHELAN AVE NE WATER PROFILE SCALE: HORIZONTAL: 1 " = 20' VERTICAL: 1" = 5' Know what's below. 0111 before you dig. HORIZONTAL BASIS OF BEARING: THE MONUMENTED CENTERLINE OF NE 10TH STREET BETWEEN CHELAN AVENUE NE AND DUVALL AVE NE PER CITY OF RENTON SHORT PLAT RECORDED UNDER RECORDING NUMBER 20120110900001 N 88030'08" W EQUIPMENT USED: TOPCON PS 103A TOTAL STATION. STANDARD FIELD TRAVERSE METHODS FOR CONTROL AND STAKING. v CITY OF RENTOR Planning/Building/Public Works Dept. CONCRETE THRUST BLOCKING PER COR STANDARD PLAN 300.6 (SEE SHEET C14.0) BEYLER CONSULTING CONTACT phone: 253-301-4157 OFFICE fax: 253-336-3950 5920 100TH ST SW, STE 25 beylerconsulting.com Lakewood, WA 98499 W-392402 IN COMPLIANCE WITH CITY OF RENTON STANDARDS EPMENT ENGINEERING WATER UTILITY + + [Abdoul Gafour 04/ 0/201 I- mes 04/30/2018 3 8 ' BOUN SHORT PLAT CONSTRUCTION PLANS LUA16-000124, SHPL-A, U16-006297 WATER PLAN & PROFILE DUVALL AVE NE _j It It O DATE: 12/14/2017 1: FIELDBOOK: NA U) PAGE: NA Z DRAWING NO: C13 SHEET: 1 OF:1 M