HomeMy WebLinkAboutR-436219N
co
co
W
DRIP CONTROL VALVE
ill =30'
JUNCTION
1-INCH CONDUIT
FITTINGS TO PO1
SUF
POWER SUPPLY V
3ATION CONTROLLER:
TROLLER IN CABINET WITH
L MOUNT. INSTALL CONTROLLER AND
NET ON WALL PER MANUFACTURER'S
DMMENDATIONS.
CONDUIT AND
3S FOR STATION
TO REMOTE
,OL VALVES
NOTES:
1. FOR EASE OF INSTALLATION INTO A CONTROLLER WITH MORE THAN 24 STATIONS, INSTALL A JUNCTION
BOX AT THE BASE OF CONTROLLER AND TRANSITION LARGER VALVE AND COMMON WIRES FROM
FIELD TO 18 AWG MULTI CONDUCTOR WIRE TO BE USED IN CONTROLLER.
2. USE STEEL CONDUIT FOR ABOVE GRADE AND SCH 40 PVC CONDUIT FOR BELOW GRADE CONDITIONS.
3. PROVIDE PROPER GROUNDING COMPONENTS TO ACHIEVE GROUND RESISTANCE OF 10 OHMS OR LESS.
IRRIGATION CONTROLLER
1" = 10' SEA-090-191-000-42
0 FINISH GRADE/TOP OF MULCH
2 VALVE BOX WITH LOCKING COVER
3 REMOTE CONTROL VALVE
4 30-INCH LINEAR LENGTH OF WIRE, COILED
5 WATERPROOF CONNECTION
6 ID TAG
7 PRESSURE REGULATING QUICK CHECK BASKET FILTER
$ PVC SCH 80 NIPPLE (LENGTH AS REQUIRED)
J PVC SCH 40 ELL
1 PVC SCH 80 NIPPLE (2-INCH LENGTH, HIDDEN) AND
PVC SCH 40 ELL
11 PVC SCH 40 TEE OR ELL
12 MAINLINE PIPE
13 6-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL
14 PVC SCH 80 NIPPLE, CLOSE
116
PVC SCH 40 ELL
PVC SCH 40 TEE
LATERAL PIPE
PVC SCH 40 FEMALE ADAPTOR
PLAN
SEA-090-191-000-44
VALVE BOX WITH COVER
FINISHED GRADE/ TOP
OF MULCH
QUICK -COUPLING VALVE
PVC SCH 80 NIPPLE
6-INCH MINIMUM DEPTH OF
3/4-INCH WASHED GRAVEL
3RICK (1 EACH CORNER) SUPPORT
SCH 80 NIPPLE
STAINLESS STEEL GEAR
CLAMPS OR EQUIVALENT
SUPPORT SYSTEM
PVC SCH 40 SWEEP ELL -
PVC SCH 40 ELL-
SCH 40 SWEEP ELL
SCH 40 TEE OR ELL
ILINE PIPE
NOTE:
FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE
INLET SIZE.
TYPICAL QUICK COUPLER
1 /2" = 1'-0"
SEA-090-191-000-46
-III-III-I
IIII�IIIIII
MASTER CONTROL
VALVE AS SPECIFIED.
WATERPROOF WIRE
CONNECTORS,ON
30" LOOPED WIRES.
SCH 80 NIPPLES,
VALVE INLET SIZE.
J
AT BOTTOM OF EACH BOX:
1/2" WIRE CLOTH GOPHER SCREEN, WRAP
UP SIDES, OVER BRICK SUPPORTS,
ONE EACH SIDE (TWO PER BOX).
NDS RECTANGULAR BOXES WITH 6' EXTENSIONS AS REQUIRED.
FINISHED GRADE.
11 I I1 I I1 I I1 11 I IIII=III1 I I_
SCHEDULE 80 NIPPLES, VALVE INLET SIZE.
FLOW SENSOR AS SPECIFIED.
/ WATERPROOF WIRE CONNECTORS ON
18" LOOPED WIRES.
SENSOR CABLE TO CONTROLLER
SENSOR TERMINAL BOARD
FLOW F�
X X X[j x bC X X
REDUCER AS REQUIRED.
_FIVE PIPE DIAMETERS I I TEN PIPE DIAMETERS
NO VALVES, REDUCERS, OR ELBOWS IN THIS AREA.
MASTER CONTROL VALVE / FLOW SENSOR ASSEMBLY
1"=20'
NOZZLES
FINISHE
GRADE/TOP
OF MULCH
���I/✓//�Il��r � ���lM�'V Vl1llN�'V
I --I I IMI
-
OP -UP SPRAY SPRINKLER ON
-P
RISER AS SPECIFIED PER
— —
—III
I IRRIGATION SCHEDULE
SCH 40 SWEEP ELBOW
/2" FLEX PIPE, LENGTH AS NEEDED
ATERAL TEE
LATERAL PIP
TYPICAL SPRAY / ROTAR HEAD
1" = 20' SEA-090-191-000-47
W J
as
�U
=O
ww
�ie
PVC MAIN LINE
FROM BACKFLOW
DEVICE.
SEA-090-191-000-43
REDUCED PRESSURE BACKFLOW DEVICE
AS SPECIFIED
BACKFLOW ENCLOSURE
GALVANIZED NIPPLES AND
ELBOW AS REQUIRED
GALVANIZED UNIONS AT EACH
SIDE
GALVANIZED RISERS
FINISHED GRADE
I I I I I I I I I I III I III I_ I I I III I I — ONCRETE THRUST BLOCKS,
90LBS OF CONCRETE (TYP)
I i lI —1 I —III —III GALVANIZED ELBOW AND
—1 I— NIPPLE, TYPICAL EA. SIDE
_ VC COUPLER AND SCHEDULE
—III 80 TOE NIPPLE, TYPICAL EACH
I- SIDE
SERVICE SID Q : I I — FLOW
--MAIN LINE, SIZE AS
1-III—III— PER PLANS
�I-III
BACKFLOW PREVENTER
1 /2" = 1'-0" SEA-090-191-000-45
R-436219
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
HHuynh 07/22/2025 '
CURRENT PLANNING o 7
jding 07/22/2025 '
J I
QBULLETIN 1 TB 6.24.251 SURVEYED: SCALE: DATE:
VERTICAL: NAVD 6/10/25
HORIZONTAL: NAD ,983/183,,99, •
DESIGNED: CITY Y OF C H I P OT L E 10 8T H AVE SE
FIELDBOOK:
RENTON
DRAWN: RL PAGE:
VR
ONE INCH DATUM vul• DRAWING NO:
CHECKED: SE AT FULL SCALE Planning/Building/Public Works Dept. IRRIGATION DETAILS L6.2
IF NOT ONE INCH
W NO. REVISION BY DATE APPR APPROVED: SHEEP: OF:
J SCALE ACCORDINGLY
U- 16 19
T
N
O
N
O
O
LO
N
CU