Loading...
HomeMy WebLinkAboutMFP25003634.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP25003634 IVR Number: 25003634 Permit Information Permit Name: Puget Sound Energy Gas Permits 109102766Address/Location:07/17/2025Application Date:0886610050Parcel Number: 737 N 6TH ST Permit Type:08/12/2025Issue Date:Franchise Permit Work Class:08/12/2026Expiration Date:Major Utility Job Number: 109102766Franchise Type:Natural Gas Description: PSE Gas Pre Construction meeting Required. Crew to Install 439' of 2" PE arterial gas main and 688' of 2" PE non arterial gas main. Retire 2 HP gas services and tie them back onto the new IP main as IP gas services. All restoration to be completed to City of Renton Standards. Contacts Name Address PhoneTypeBilling Katie Zimmerman Puget Sound Energy 1660 Park Lane Burlington, WA 98233 B: (425) 620-6742 C: (425) 620-6742 ApplicantX Permits Central 355 110th Ave NE Bellevue, WA 98004 B: (425) 620-6742 H: (425) 620-6742 C: (425) 620-6742 Contact Stuart Bennett Infrasource Services LLC 1622 Eastport Plaza Dr Collinsville, IL 62234 B: (303) 419-8755 H: (425) 677-5197 C: (713) 985-6489 Contact INFRASOURCE SVCS B: (206) 949-5846Contractor Business License Number: 36742Construction Contractor: INFRASL871C2 Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08 Bellevue, WA 98009 B: (888) 225-5773Emergency Contact CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Katie Zimmerman Puget Sound Energy 1660 Park Lane Burlington, WA 98233 B: (425) 620-6742 C: (425) 620-6742 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. PUBLIC WORKS DEPARTMENT Page 1 of 6 | Published: 2/25/2025 Transportation Systems Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 2/25/2025 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK AND FOR TRAFFIC SIGNAL WORK WITHIN 150 FEET OF THE INTERSECTION AT LEAST FIFTEEN (15) WORKING DAYS BEFORE THE DATE OF WORK. FOR PURPOSES OF THIS APPLICATION, WORKING DAYS ARE DEFINED AS MONDAY THRU FRIDAY, AND EXCLUDING CITY HOLIDAYS. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a Traffic Control Plan (TCP) and obtain City's approval of that plan when construction, repair, or maintenance work is to be conducted within the City's right-of-way. 1.Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2.All TCPs must conform to all attached requirements. Failure to do so may be subject to resubmittal. 3.Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” 4.Resubmittal may be required for TCPs that are incomplete and do not display proper requirements as described in the guidelines. Additional review time may be needed. By signing, I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge and have read all the requirements and guidelines on this application. Applicant’s Signature Date Applicant’s Name (Print) Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: ___________ Description of Work: 24 Hour Emergency Contact Name & Phone: Approval By: ______________________________________________ Date:____________________ PW/Transportation or CED/Development Engineering Division 6905 S 228th St Kent, WA 98466 Please See Attached Infrasource, Inc Katie Zimmerman 7/17/2025 109102766 737 N 6th St Jocelyn Means 206-305-8570 MFP25003634 Monday Friday 8:00am 3:00pm Scott Warlick CED 8/12/2025 Page 2 of 6 | Published: 2/25/2025 This Page Intentionally Left Blank Page 3 of 6 | Published: 2/25/2025 APPLICANT AGREES TO ALL THE FOLLOWING REQUIREMENTS: GENERAL • Applicant is responsible for compliance with all traffic regulations of the City of Renton (City) and the State of Washington, including codes and regulations not described in this application. • Work Zone Traffic Control shall be in accordance with Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to Washington State Department of Transportation (WSDOT) traffic control plans. • Any lane or street closures not in conformance with the approved Traffic Control Plan (TCP) and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved TCPs including claims arising from towing of private vehicles and the acts of Applicant’s agents and employees. • Applicant must comply with all conditions of the application. • The City shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this application, Applicant is responsible to pay for legal counsel chosen by the City to defend against same. • No more than one TCP shall be in use at any given time for a single project. If multiple TCPs are submitted for review and approval at the same time, the TCPs shall be clearly labeled as separate plans and include construction phasing and sequencing. • Previously approved TCPs cannot be combined into a new TCP without review and approval by the City. • Expired TCP is not valid and shall not be used. Applicant shall resubmit the expired TCP for approval with the updated date and time and/or any changes to TCP. • Applicant must have the approved TCP prior to commencing the work. • Approved TCP must be at the work site during work hours. • Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. • At signalized intersections, vehicle detection shall always remain operational, unless approved in this TCP and notified Transportation Signal Maintenance prior to commencing work. If damage occurs to existing vehicle detection that is to remain, it is Applicant’s responsibility to replace with video vehicle detection equipment that meets current City’s standards at Applicant’s expense. • When not in use, temporary traffic control devices shall be removed or covered immediately. It is the Applicant’s responsible to cover any temporary traffic control devices when not applicable for the construction activities. Similarly, when work is suspended for short periods of time, traffic control devices that are no longer necessary shall be removed or covered. If deemed abandoned, City crews will remove and may store them at the City’s maintenance shop (3555 NE 2nd Street) for up to sixty (60) days. The City is not responsible for any private property from City assets and identifying the property owner. • Applicant is responsible to maintain existing pedestrian accessible routes during work and non-work hours. At intersections, the work on pedestrian facilities shall be limited to one (1) corner at a time, with the least possible inconvenience or delay to pedestrians. Pedestrian pushbuttons shall remain accessible at all times, unless approved pedestrian accessible detour(s) are provided. Accessibility to existing or temporary Page 4 of 6 | Published: 2/25/2025 pedestrian pushbuttons shall not be impaired. Deficiencies caused by Applicant’s operations shall be repaired at Applicant’s expense. • Applicant shall provide complete assistance and accommodation from a dedicated pedestrian escort to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. • Driveway and alley access shall be maintained at all times, also see RMC Chapters 9 and 10 for Street Closure and Street Excavation for details. Applicant is responsible for coordinating with the property owners and/or residents prior to commencement of the work. • Pavement excavation shall be limited to a maximum of one travel lane at a time unless otherwise approved. • Accessibility for emergency vehicles shall be maintained at all times. PUBLIC OUTREACH • Applicant must notify Transportation Signal Maintenance (425-430-7423) and City inspector (425-430- 7203) at least twenty-four (24) hours before commencing work (lane shift/closure or near a signal) affecting the vehicle detection. • Applicant shall notify emergency services (253-852-2121) twenty-four (24) hours before any street closures or lane closures. • Applicant shall call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five (5) working days (excluding weekends and holidays) prior to starting any work. • Applicant shall coordinate with King County Metro Transit Construction Information Center (206-477-1140 or construction.coord@kingcounty.gov) for any construction or installation activities affecting transit operations or facilities. Notification information and guidelines can be found at: https://kingcounty.gov/en/dept/metro/about/contractor-resources/transit-system-impacts. WORKING DAYS AND TIMES • Normal working days are Monday through Friday. Work on holidays, weekends or at night shall not occur without City’s approval. For work times between 10:00 p.m. and 7:00 a.m., see Night Work section below for details. • Work time begins when any street or travel lane is fully or partially closed. This includes set up and removal within the traveled way. • If the City determines the closure hours adversely affect traffic during the work, the City may require to adjust or reduce the working hours accordingly. Reduced work hours may be required by the City to minimize traffic impacts for any work located near a school during pick-up and drop-off times or on an arterial street. (See WSDOT Functional Classification Map: https://www.wsdot.wa.gov/data/tools/geoportal/?config=FunctionalClass) • Applicant may request the City for consideration of extended or modified working hours. Such request must be approved by the City before changing hours of work. CLOSURES • All closure hours and days are subject to local permit and ordinance conditions (such as noise ordinances). More information can be found on https://www.rentonwa.gov/City-Services/Permit-Center. Total street closure lasting more than twenty-four (24) hours is subject to City Council authorization per Section 9-9 of the Renton Municipal Code (RMC). • Road closure notice – Applicant must install Portable Changeable Message Sign (PCMS) boards no less than five (5) working days in advance of effective date and time, not including holidays, at location(s) as identified in the TCP. Other methods of displaying the messages shall be approved by the City. Page 5 of 6 | Published: 2/25/2025 • Road closure notice messages must include at least the following:  ROAD WILL BE CLOSED  MONTH/DAY – MONTH/DAY  _AM - _PM • Road and/or sidewalk closure must be evaluated by the City with respect to both the necessity as well as the impact of the closure to the public. Applicant shall submit detour plans for road closures to accommodate both motorized and non-motorized users, including accessible pedestrian route(s). Road closures shall require additional temporary traffic control including advance notification, approach and detour signage. • Applicant is responsible to temporarily remove the flags and install bags over the flag holders for any work requiring the temporary closure of a crosswalk equipped with pedestrian flags. Applicant shall ensure the bags remain intact and shall replace damaged bags as needed or determined necessary by the City of Renton inspector. For any misplaced or lost flags, Applicant is responsible to replace at Applicant’s own expense. Upon restoration of the crosswalk, Applicant shall remove the bags and return all flags to the holders. Inventory of pedestrian flags must be submitted to the City inspector and reported to City of Renton Transportation Signal Maintenance (425-430-7423) prior to removal. UNIFORMED POLICE OFFICERS (UPO) / FLAGGERS • Any construction activities within one hundred and fifty (150) feet of a signalized intersection shall require Uniformed Police Officer(s) (UPO) at the traffic signal, unless otherwise approved in this TCP and evaluated by City Transportation for the impacts of traffic signal operations and safety. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • For TCPs that require the presence of UPO to manage vehicular traffic and pedestrians at signalized intersections, Applicant shall coordinate with Transportation Signal Maintenance (425-430-7423) at least twenty-four (24) hours in advance for any signal that will be placed in red flashing mode. Applicant shall notify Transportation Signal Maintenance when the intersection is back to the normal traffic signal operations. TEMPORARY TRAFFIC SIGNALS OR TRAFFIC SIGNAL MODIFICATION • Temporary traffic signal programming or modification requires a minimum fifteen (15) working days for each traffic signal controller to be programmed and tested by City Transportation staff before starting the work. The Start Date on this TCP shall reflect the time for temporary traffic signal programming or modification. TEMPORARY NO-PARKING • Applicant must post notice of date(s) and time(s) of Temporary No Parking Zone with signs at every hundred (100) feet at least seventy-two (72) hours in advance of effective date and time. • Applicant is responsible to show on the TCP the limits of Temporary No Parking Zone, identifying barricade locations for vacate parking or curb lane usage. The cover sheet of this approved TCP form must be attached to each Temporary No Parking Sign on the project site. • Two travel lanes (one for each approach) must be open at all times on arterial streets unless approved in this TCP. NIGHT WORK • Between the hours of 10 p.m. and 7 a.m., approved Noise Variance shall be required (See Section RMC 8-7- 8) for night work. Process may take up to twelve (12) weeks. More information can be found at https://www.rentonwa.gov/City-Services/Permit-Center/Land-Use-Development/Noise-Variance. • City may require night work for TCPs that have severe traffic impacts on arterial streets. Page 6 of 6 | Published: 2/25/2025 • Night work shall always be required if two lanes of traffic (One for each approach) cannot be maintained on an arterial street. • Night work shall be required if an evaluation of existing traffic volumes and patterns finds that any TCP will functionally reduce an arterial or high-volume collector street to only one lane of traffic. • The following configurations may require night work:  Work at traffic signals that requires shifting one direction of traffic into a left turn pocket where a high volume of left turns occur.  Work at traffic signals that requires shifting two directions of traffic into left turn pockets.  Work at traffic signals that requires shifting high-volume left-turn movement into a through lane on a single approach to the intersection.  Work at signals that requires shifting left-turning traffic into a through lane on multiple approaches to the intersection. • If City’s initial TCP review finds that night work is required, a pre-construction meeting is mandatory to confirm the extents of the work required, the duration of work, anticipated noise levels, and any potential alternatives to mitigate the impact of night work to adjacent residents prior to review and approval of the TCP. TRAFFIC CONTROL PLAN (TCP) FORMAT • TCP must be site and project specific. The TCP shall clearly indicate all existing transportation facilities impacted by work including roads, bike lanes, sidewalks, transit stops, and driveways. Typical drawings, taper tables and MUTCD illustrations, by themselves, are insufficient. • Each construction phase shall be provided with appropriate work zone traffic control. The impacts of utility relocation, traffic delays, detours and capacity restrictions must be considered and addressed. A suitable sequence of construction activities must be discussed with City Staff prior to fully developing TCPs based on the complexity of a project. • TCPs shall be clearly labeled as separate plans to identify the construction sequencing during each phase when more than one TCP layout is submitted. • TCP must be submitted with an electronic copy of TCP layout(s), on 11” X 17” paper size PDF format, which consist of:  Map(s) showing the location of the project and work area.  All fonts shall be legible and a minimum 10-point font size.  All symbols of viewing or printing shall be clear and contrasting.  All streets shall be labeled, and layout must include a north arrow and scale.  Must show channelizing devices, signing, flagger locations, barricades, PCMS boards, etc.  Show locations where the standard traffic control plans are applied. 737 N 6th St Renton WA 98057 USAN 6TH STWELLS AVE N ONLY1830ONE WAY 11 11 11 11 11151518181010 BUSSTOP11111111 11 11 11 11 1111111111111211111112N 6TH STN 6TH STWILLIAMS AVE N BURNETT AVE N LOGAN AVE N LOGAN AVE NBUSSTOP RESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSUREARRW-BRD W20-1ROAD WORK AHEAD RIGHT LANECLOSEDAHEAD W20-5RW4-2RX'≥X'≥X'≥W20-1ROADWORKAHEADW20-1ROADWORKAHEADNSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVJason Bisenius425-424-7316jason.bisenius@pse.com1 OF 5737 N 6TH ST, RENTON, WA 980570 11266435 04/15/2025Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flaggers shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPWORK PITMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840RESTORATION TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Jason BiseniusCard No. ES2 000394Card Exp. 01/31/2028Jason.Bisenius@pse.com(425)424-7316MFP25003634 737 N 6th St Renton WA 98057 USA151518181010BUSSTOP 1111111111 11 11 11 11POLICEUPO11111111111211111112N 6TH STN 6TH STWILLIAMS AVE N BURNETT AVE N LOGAN AVE N LOGAN AVE NBUSSTOP 11 11 11 11 11 11111111ARRW-BRD ARRW-BRD W20-1ROADWORKAHEAD RIGHT LANE CLOSED AHEAD W20-5RW4-2RX'≥X'≥X'≥X'≥C/WCLOSEDR9-3DETOURM4-9B C/WCLOSEDR9-3DETOURM4-9BW20-1ROADWORKAHEADRIGHT LANECLOSEDAHEADW20-5RW4-2RX'≥X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7ACONETOPPERW20-1ROADWORKAHEADLEFT LANECLOSEDAHEADW20-5L X'≥X'≥X'≥ W20-7A KEEPR4-7BRIGHTW20-7AProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVJason Bisenius425-424-7316jason.bisenius@pse.com2 OF 5737 N 6TH ST, RENTON, WA 980570 11266435 04/15/2025Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flaggers shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPWORK PITMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840RESTORATION TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Jason BiseniusCard No. ES2 000394Card Exp. 01/31/2028Jason.Bisenius@pse.com(425)424-7316NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040MFP25003634 737 N 6th St Renton WA 98057 USAN 6TH ST11 11 11 11 11151518181010 BUS STOP 1111111111 11 11 11 11POLICEUPO11111111111211111112N 6TH STN 6TH STWILLIAMS AVE N BURNETT AVE N LOGAN AVE N LOGAN AVE NBUSSTOP ARRW-BRD W20-1ROADWORKAHEAD W20-5RRIGHTTWO LANESCLOSEDAHEADW4-2RX'≥X'≥X'≥X'≥C/WCLOSEDR9-3 DETOURM4-9B C/WCLOSEDR9-3DETOURM4-9B11 11 11 11 11 W20-7ALEFT KEEP R4-8B W20-1ROADWORKAHEADARRW-BRD W20-1 ROADWORKAHEADRIGHT LANECLOSEDAHEADW20-5RW4-2R X'≥X'≥X'≥X'≥ W20-7A BIKELANEENDSW9-1BBIKESMERGE WITHTRAFFICW4-1BX'≥X'≥11111111W20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADLEFT LANECLOSEDAHEADW20-5LX'≥X'≥X'≥W20-7ACONETOPPER 11111112 TEMPORARY BUS STOPProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVJason Bisenius425-424-7316jason.bisenius@pse.com3 OF 5737 N 6TH ST, RENTON, WA 980570 11266435 04/15/2025Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flaggers shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPWORK PITMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840RESTORATION TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Jason BiseniusCard No. ES2 000394Card Exp. 01/31/2028Jason.Bisenius@pse.com(425)424-7316NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040MFP25003634 1515BUSSTOP 1111111111 11 11 11 11 121112TRUCKSONLYTRUCKSONLYTRUCKSONLYTHRULANEONLY121112 12 11 11121111 11111111111211111112 11 11 N 6TH STN 6TH STBURNETT AVE N LOGAN AVE N LOGAN AVE NBUSSTOP 11111111ARRW-BRD W20-1ROAD WORK AHEAD RIGHT LANECLOSEDAHEAD W20-5RW4-2RX'≥X'≥X'≥W20-1ROADWORKAHEAD X'≥W20-1ROADWORKAHEADX'≥ KEEPR4-7BRIGHTCONETOPPERW20-1ROADWORKAHEADLEFT LANECLOSEDAHEADW20-5LX'≥X'≥Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVJason Bisenius425-424-7316jason.bisenius@pse.com4 OF 5737 N 6TH ST, RENTON, WA 980570 11266435 04/15/2025Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flaggers shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPWORK PITMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840RESTORATION TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Jason BiseniusCard No. ES2 000394Card Exp. 01/31/2028Jason.Bisenius@pse.com(425)424-7316NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040MFP25003634 121112TRUCKSONLYTRUCKSONLYTRUCKSONLYTHRULANEONLY 121112 12 11 111211111111 N 6TH ST121112STOP W20-1ROADWORKAHEADW2 0 - 4 ONE LANEROADAHEADX'≥ X'≥ X'≥ W2 0 - 7 A STOP W20-7ACONETOPPER ARRW-BRDSTOP W20-1ROADWORK AHEAD RIGHT LANECLOSEDAHEAD W20-5RW4-2RX'≥X'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADLEFT LANECLOSEDAHEADW20-5LX'≥X'≥X'≥W20-7ALOGAN AVE NN 6TH ST1211111112N 6TH STSTOP THE CREW SHALL CEASEWORK AND ESCORT PEDESTRIANSAROUND/THRU WORK AREAProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVJason Bisenius425-424-7316jason.bisenius@pse.com5 OF 5737 N 6TH ST, RENTON, WA 980570 11266435 04/15/2025Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flaggers shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPWORK PITMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840RESTORATION TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Jason BiseniusCard No. ES2 000394Card Exp. 01/31/2028Jason.Bisenius@pse.com(425)424-7316NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040PLACE W20-1 SIGNS ON ALLADJACENT STREETS WITHINX' FEET OF WORK AREA(USE SIGN SPACING CHART)W20-1 ROADWORKAHEADW20-1ROADWORKAHEADMFP25003634 Owner / Developer Contact Info officeATTN: THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) 109160181 108653203 108655230 GAS PROJECT PHASE Notification #Order # Retire SVCs Retire SVCs SAP Superior Service/Meter Service/Meter HP Svc/MSA Dis. Reg. / FT Ind. MSA Ind. Service Service/Meter Service/Meter AREA VIEW SCALE: N.T.S. LEGEND FIELD NOTES: FIELD DESIGNER: CELL: EMAIL: CONSTRUCTION QUESTIONS: PROJECT CONTACT INFORMATION: CONST MANAGER: CELL: EMAIL: PROJ MANAGER: CELL: EMAIL: FOR MAIN DESIGNS REALIGNMENTS - FIELD DESIGNER SHALL BE CONTACTED: BILLING QUESTIONS: 925-450-3083 NYA HILL nya.hill@pse.com 206-255-4824 STEVE MELLINGER steve.mellinger@pse.com 206-305-8570 JOCELYN MEANS jocelyn.means@pse.com Cell Phone: "Locates Required" "Flagging Required" Yes No Yes No E-Mail: Manager: Project Manager Contact Information: JOCELYN MEANS 206-305-8570 jocelyn.means@pse.com 109102766HOLE HOG/BORE TABLE CALLOUT LOCATION DEPTH LENGTH BP1 START BP2 END BP3 START BP4 END BP5 START BP6 END BP7 START BP8 END BP9 START BP10 END BP11 START BP12 END BP13 START BP14 END BP15 START BP16 END BP17 START BP18 END BP19 START BP20 END BP21 START BP22 END BP23 START BP24 END STOP TIME START TIME GAS MAIN PRESSURE & TESTING TESTED BY GAS MAIN INSTALLATION/RETIREMENT SOAP AIR NITROGEN WATER SOAP AIR NITROGEN WATER STOP TIME START TIME TESTED BY TEST RESULTS P F TESTED BY PSE PRESSURE CONTROL, SEE FORM 1928 P F Type/Work ManufacturerPipe Size Type Est Length Act Lgth TYPE TEST / / DATE OFF PRESSURE DATE ON DATE OFF TYPE TEST PRESSURE SYS MAOPDESIGN PRESS DATE ON 2023 02/18 TEST RESULTS / / / / / / Verify Testing Requirements, Chart vs Gauge GOS 2525.3300 sec. 5, Table 5-1 and sec. 5.5 GASSED UP PIPELINE PIPE SEGMENT FOREMAN'SDATENAME INSTALL 2"MPE 439' INSTALL 2"MPE 688' 60 PSIG 45 PSIG Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: __________________________ Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr PC APPROVAL 1/6 J.MEANS 206-305-8570 N.HILL 925-450-3083 H.NGUYEN 303-788-9142 M.LOCK 425-424-6413 A.ALEXANDER 925-394-2228 B.JOHNSON 206-571-8519 6-13-24 N/A RENTON 2" MPE MAIN EXTENSION 737 N 6TH ST RENTON, WA 98057 PUGET SOUND ENERGY 109102766 109102766 1"=20' KING 498 PMPDPM13 SE 7-23-05 E / SW 8-23-05 E 204.080 207.081/207.082 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 10910276611266435 STANDARD GAS CONSTRUCTION NOTES: 1.FIELD LOCATE ALL UNDERGROUND UTILITIES. EXCAVATOR TO CALL "ONE-CALL" TWO WORKING DAYS PRIOR TO CONSTRUCTION, IN WESTERN WASHINGTON CALL: 1-800-424-5555. OR CALL NATIONWIDE: 811 2.NOTIFY APPROPRIATE PERMITTING AGENCY PRIOR TO JOB START (SEE PERMIT REQUIREMENTS). 3.ALL CONSTRUCTION IS TO CONFORM TO PSE GAS OPERATING STANDARDS AND GAS FIELD PROCEDURES. 4.EROSION AND SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE 0150.3200 TECHNIQUES FOR TEMPORARY EROSION AND SEDIMENT CONTROL AND ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. 5.NOTIFY PROPERTY OWNERS ADJACENT TO PROPOSED CONSTRUCTION ACTIVITIES A MINIMUM OF TWO WORKING DAYS PRIOR TO BEGINNING CONSTRUCTION. USE iSi TO DISTRIBUTE FLYERS IF JOB IS LARGE, OTHERWISE HAND DELIVER FLYERS BE SURE TO INCLUDE THE LIST OF FREQUENTLY ASKED QUESTIONS AND INFORMATION ABOUT THE OPPORTUNITY TO PURCHASE AN EXCESS FLOW VALVE WHEN THEIR SERVICE IS INSTALLED OR REPLACED PER GAS OPERATING STANDARD 2550.1600. ALLOW ADEQUATE TIME FOR CUSTOMER DECISION AND RESPONSE. 6.ANY CHANGE IN ROUTE, PIPE SIZE/TYPE, TIE-IN METHOD OR ADDITIONAL MAIN FOOTAGE MUST BE APPROVED BY THE APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE. 7.COMPLETE "PIPE CONDITION REPORT" ON ALL METALLIC PSE FACILITIES. CHECK BOX ON REPORT FOR WIRE BOX (TEST LEAD) INSTALLATION. 8.PIPELINE MARKERS AND WARNING SIGNS SHALL BE INSTALLED AND RECORDED BY THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2500. 9.INSTALL MAIN VALVES OUT OF TRAFFIC WHERE POSSIBLE. VALVE MARKERS SHALL BE INSTALLED AND RECORDED BY THE CONTRACTOR PER PSE GAS OPERATING STANDARD 2525.2600 FOR ALL HP VALVES IF THE LOCATION IS NOT READILY ACCESSIBLE, AND FOR ALL VALVES WHERE PERSISTENT SNOWFALL MAY OBSCURE THE VALVE BOX. 10.TO PREVENT ACCIDENTAL OVERPRESSURE OF ADJOINING SYSTEMS, NO TWO MAINS SHALL BE CONNECTED EXCEPT AS SHOWN ON THIS DESIGN UNLESS APPROVED BY APPROPRIATE PSE ENGINEER OR PSE REPRESENTATIVE. 11.SYSTEM MAOP DENOTED BY: SYSTEM MAOP = 45 PSIG 12.GAUGE AND MONITOR USE OF ALL STOPPERS TO ENSURE ADEQUATE FEED. 13.RESTORE ALL DRIVEWAYS SUBJECT TO OPEN CUT TO ORIGINAL OR BETTER CONDITION. 14.PURGE POINTS TO BE INSTALLED PER PSE GAS OPERATING STANDARDS 2525.3400. 15.MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300 AND 2525.3400. 16.IF METALLIC PIPE IS INVOLVED, COORDINATE INSTALLATION WITH CP TECH. ____B.JOHNSON__________________________, PHONE___206-571-8519___________. 17.NOTE ALL ACTUAL FOOTAGE, LOCATION AND MATERIAL CHANGES ON THE AS-BUILT IN RED. ( ') DENOTES FOOTAGE BETWEEN FITTINGS. 18.EXCESS FLOW VALVE TO BE INSTALLED ON ALL NEW RESIDENTIAL SERVICES PER GOS 2500.2200. (RECORD ALL INFORMATION ON D-4 CARD) STANDARD IP & LP GAS REPLACEMENT CONSTRUCTION NOTES 1.NOTIFY GAS CUSTOMERS, OR DISTRIBUTE FLYER #1443 A MINIMUM OF TWO WORKING DAYS PRIOR TO A PLANNED OUTAGE. 2.INSTALL ONE POUND ANODE FOR EVERY 1000' OF LOCATING WIRE. INSTALL ANODE AND TEST LEAD WIRES PER PSE GAS OPERATING STANDARD 2525.2300. 3.MAINTAIN CATHODIC PROTECTION FOR STEEL MAINS BY THE USE OF CONTINUITY BONDS OR OTHER MEANS DETERMINED BY THE PSE CORROSION ENGINEER PER PSE GAS OPERATING STANDARD 2600.1300. 4.INSTALL ANODES AND TEST LEAD WIRES AS REQUIRED PER PSE GAS FIELD PROCEDURES 4515.1000 AND 4515.1020 AND PSE GAS OPERATING STANDARD 2600.1200. TEST LEAD WIRES ARE REQUIRED ON ALL TRANSITION FITTINGS. 5.INSTALL CURB VALVE AT PROPERTY LINE OR 5/8" PE WHIP AT MAIN (AS REQUIRED) ON NEW AND EXISTING SERVICES PER PSE GAS OPERATING STANDARD 2550.1600. 6.REFER TO PSE GAS OPERATING STANDARD 2525.1700 FOR MAIN AND SERVICE COVER REQUIREMENTS. 7.MAINS AND SERVICES SHALL BE TESTED AND PURGED PER PSE GAS OPERATING STANDARDS 2525.3300 AND 2525.3400 AND PSE GAS FIELD PROCEDURE 4700.1500. 8.PROJECT MANAGER TO MAKE AN ACTIVE SERVICE RUN IMMEDIATELY PRIOR TO STARTING CONSTRUCTION. 9.INSTALL REPLACEMENT MAINS PER PSE GAS OPERATING STANDARD 2525.2100. 10.PLUG ENDS OF DEACTIVATED OR INSERTED MAINS AND SERVICES IN ACCORDANCE WITH PSE GAS OPERATING STANDARDS 2525.2100 AND 2525.3600. 11.REMOVE OR RENDER INOPERABLE DEACTIVATED VALVES ON CASING WHERE MPE PIPE IS INSERTED. 12.INSIDE METER SETS SHALL BE MOVED OUTSIDE WHENEVER POSSIBLE OR SET REGULATORS AND VENTS OUTSIDE PER PSE GAS OPERATING STANDARDS 2575.2300 AND 2550.1700. 13.REPLACE EXISTING ACTIVE SERVICES PER PSE GAS OPERATING STANDARDS 2525.2100 AND 2575.2300. 14.REPLACE ALL "NO RECORD" SERVICES AND 1-1/8" PE SERVICES INSTALLED PRIOR TO 1985. 15.ACTIVE SERVICES TO BE REPLACED DENOTED BY: 16.MAINS AND SERVICES SHALL BE CONSTRUCTED IN ACCORDANCE WITH 2525.1200. 17. PIPE SQUEEZING SHALL BE DONE IN ACCORDANCE WITH GOS 2525.1200 AND GAS FIELD PROCEDURES 4700.1300 AND 4700.1310. 18.WHEN INSTALLING, DEACTIVATING, REPAIRING, OR OTHERWISE MODIFYING A PIPELINE THAT IS LOCATED WITHIN 200 FEET OF ANY ACTIVE REGULATING STATION, PRESSURE RELIEF AND LIMITING DEVICE, OR SINGLE SERVICE FARM TAP WHERE GAS SYSTEM ENGINEERING REVIEW AND APPROVAL IS REQUIRED PER GAS OPERATING STANDARDS. SEE REVIEW DOCUMENTS, PROVIDED BY ENGINEERING. 19.FIELD TO VERIFY THAT ALL PROPER SERVICE ACTIONS (FOLLOWING THE KEY TO SERVICE ACTION LEGEND) HAVE BEEN ACCOUNTED FOR PER THE "SERVICE CHECKLIST". IF A RISER IS FOUND IN THE FIELD AND WASN'T ACCOUNTED FOR, FIELD PERSONNEL SHALL CONFIRM WHETHER THE RISER IS AN ABANDONED OR IDLE RISER: 19.1 IF IT IS AN ABANDONED RISER, CONTACT THE POINT DESK TO REQUEST GFR TO REMOVE IT. 19.2 IF IT IS AN IDLE RISER, REPORT THE RISER TO THE PROJECT MANAGER SO THAT THE PROJECT MANAGER MAY CONFIRM WITH THE CUSTOMER WHETHER THEY WOULD LIKE TO KEEP THE SERVICE AND RISER. THE PROJECT MANAGER MAY INSTRUCT TO TEST AND TIE THE SERVICE IF THE CUSTOMER WANTS GAS OR DOESN'T PROVIDE PSE A RESPONSE IN A TIMELY MANNER. ### 1.ALL DUPONT AND STW PIPES SHALL BE RETIRED PER SCOPE OF WORK. 2.NOTIFY PROJECT MANAGER IF ADDITIONAL DUPONT AND/OR STW MATERIALS ARE FOUND DURING CONSTRUCTION, INCLUDING AT OR BEYOND THE CONNECTION POINTS. ### T&T ### KEY TO SERVICE ACTION T&T C&C RWM ### ### ### ### METHOD OF CONSTRUCTION 109160182 SHEET 3 SHEET 4 SHEET 5 N 6TH ST LOGAN AVE NLOGAN AVE NN 6TH ST (ARTERIAL)BURNETT AVE NWILLIAMS AVE NARTERIAL(ARTERIAL)(ARTERIAL)This permit is for Major construction work in the ROW and will be billed at an additional $158/HR for inspections. After hours and weekend work will be billed at $175/HR PRE-CONSTRUCTION MEETING REQUIRED POTHOLE ALL EXISTING UTILITIES RESTORATION PER CITY OF RENTON STANDARDS MFP25003634 GAS OPERATIONS MAP SCALE: NONE Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: __________________________ Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr PC APPROVAL 2/6 J.MEANS 206-305-8570 N.HILL 925-450-3083 H.NGUYEN 303-788-9142 M.LOCK 425-424-6413 A.ALEXANDER 925-394-2228 B.JOHNSON 206-571-8519 6-13-24 N/A RENTON 2" MPE MAIN EXTENSION 737 N 6TH ST RENTON, WA 98057 PUGET SOUND ENERGY 109102766 109102766 N/A KING 498 PMPDPM13 SE 7-23-05 E / SW 8-23-05 E 204.080 207.081/207.082 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A WORK SITE MFP25003634 P P P P P PGGPPPPP P P P P P P P P P TPC 1/2" REBAR NO CAP 0.2' ABOVE GRADE UT xxxxxxxxUTUTUTxxxxxxxxGGGGGGGGGGT T TUTUTUTUTUTUTWWPP P P P P PPPP T T T T T T T TT T T G G G G G G G G G G x x x x x x FOFOFOFOFOPPUTUTFOFOT T T T T T T T T T T T T T T T T T TT P P P P PPP P P P P P P P P P P P PPPP P P P G G G G G G G G G G G G G G G G G G G G G G Gxxxxxxxxxxxxxxxxxxxxxxxx SDMH RIM=26.12 24" CIP E,W IE=18.5 SDMH RIM=28.35 8" RCP NW IE=22.9 24" CIP W IE=19.6 24" DI E IE=19.6 SDMH RIM=28.50 24" DI W IE=19.2 24" DI E IE=19.2 12" CPP S IE=21.3 CB TYPE 1 RIM=25.84 12" CPP NW IE=21.9 CB TYPE 2 RIM=27.55 24" CIP E,W IE=19.1 CB RIM=27.98 12" CPP N IE=22.3 SSMH RIM=27.99 CANNOT ACCESS LID LOCKED ROTATING SECURITY GATE 4' CLF15MPHAW AW CW 4' CLFCGWCR CW BUILDING 7' CLF W/ BW CC STOPSTOP CW CW 6.5' WIF 6.5' WIF ICV(2) ECB ICV 6.5' WIF6.5' WIFCULVERT 12" CIP W TOP OF PIPE=27.5CULVERT 12" CIP E TOP OF PIPE=27.1 CULVERT 12" CIP W TOP OF PIPE=25.0 WCR CW CCCCCONC SD SD SD SD SD SD SD CONC WALL W/ 7' CLF W/ BW 7' CLF W/ BW SD SD SD SD SD SD P P P P P P P P P P PA GVL GVLCONCGVL CONC PA GVL CONC TJR ASPH ASPH PA PA P P CONC CONCPA CW EP PA DIT CONC CGCGCGCGSTOPSTOPDIT CG CGCC WV WV(2) UTIL 6" STW HP 6" STW HP 6" STW HP 6" STW HP 3/4" STW1" STW3/4" STWTOP OF DIT 7' CLF W/ BW R/W R/W30'32'30'R/W R/W30'33'30'R/W R/W30'33'0723059001 0723059001 0723059001 0723059001 6" STW HP ASPH CW CW CGCG SD24" CIP 24" CIP 24" CIP 24" CIP 24" CIP 24" DI24" CIP 24" CIP BUILDING 0723059046737 LOGAN AVE N 737 LOGAN AVE N 801 N RIVERSIDE DR737 LOGAN AVE N 737 LOGAN AVE N PA W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W P P P P P P P P x x x x x x x x x x x x x x x x x x x x x x CONC CONCP PA PA PA SSSS SSICV GM GV 6.5' WIF TTTTT T T EPEP DIT CB TYPE 2 SOLID LID RIM=29.17 24" DI W IE=19.2 24" CPP E IE=19.3 12" CPP SE IE=23.6SD24" DI 24" DI 6" STW HP SSASPH R/W R/W30'33'VARIESR/W R/W30'52.5'CG CG 24" CIP DDD D 0723059001 737 LOGAN AVE N 0723059001 737 LOGAN AVE N S (____)737PLAN VIEW SCALE: 1"=20' Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: __________________________ Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr PC APPROVAL 3/6 J.MEANS 206-305-8570 N.HILL 925-450-3083 H.NGUYEN 303-788-9142 M.LOCK 425-424-6413 A.ALEXANDER 925-394-2228 B.JOHNSON 206-571-8519 6-13-24 N/A RENTON 2" MPE MAIN EXTENSION 737 N 6TH ST RENTON, WA 98057 PUGET SOUND ENERGY 109102766 109102766 1"=20' KING 498 PMPDPM13 SE 7-23-05 E / SW 8-23-05 E 204.080 207.081/207.082 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/AMATCHLINE A-ASHEET 4N 6TH ST N RIVERSIDE DRPRIVATE ROADPRIVATE ROADMATCHLINE A-A THIS SHEET MFP25003634 SDMH RIM=31.00 8" CONC W IE=23.7, PIPE POSSIBLY ABANDONED 24" CONC S IE=19.7 WWWWWWWWP P P P P G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G GxxxxxxxxxxxxxxxxxSSMH RIM=29.62 CANNOT ACCESS/LOCKED P P P P P P PPPPP P P P P P PPP P P P P P P P P P x x x x x x x x x x x x WWWWWW W WWWGGGGFOFOT T T T T T T T T T T T P P P P PPPPPPP P xxxxx xxx xxxW W W W W W W W W W W W W W W W W WWW W W W W W W W W W WWPPPPP P P P P P P P P PP P P PPP x x x x x x x x x x x x x x x x CONC CONC CONCPAPA CB TYPE 1 RIM=28.85 12" CPP NW IE=24.9 CB TYPE 1 RIM=28.54 8" CONC NW IE=26.4 8" CONC S IE=26.5 CB TYPE 1 RIM=30.01 8" CONC N IE=26.9 CB TYPE 1 RIM=29.68 8" CONC N IE=-2.58 8" CONC SE IE=-2.86 CB TYPE 1 SOLID LID RIM=31.04 8" CONC SW IE=27.8 CB TYPE 1 RIM=30.70 8" CONC S IE=28.5 CB TYPE 1 RIM=30.93 12" CPP W IE=28.5 CB TYPE 1 RIM=30.78 12" CPP N IE=28.4 12" CPP E IE=28.5 SDMH RIM=31.78 24" CPP N IE=23.8 24" CPP W IE=20.3 24" CPP E IE=20.4 SDMH RIM=31.79 24" CPP N IE=25.2 24" CPP S IE=24.2 SDMH RIM=31.14 8" CONC NE IE=26.3 24" CONC E IE=25.6 12" CONC W IE=25.5 SDMH RIM=30.84 24" CONC W IE=25.3 12" CPP E IE=25.0 24" CONC S IE=25.5 SDMH RIM=30.70 12" CPP W IE=24.7 12" CPP N IE=21.3 24" CPP E IE=20.3 12" CONC SW IE=UNK SDMH RIM=30.60 24" CPP W IE=20.1 24" CONC N IE=20.0 24" CONC E IE=20.2 8" CONC SE IE=23.6 18" CMP S IE=21.5 SDMH RIM=30.76 15" CONC W IE=21.0 15" CONC E IE=21.0 CLOSED PIPE RUNS THROUGH 12" SDMH RIM=30.71 24" CPP E IE=19.4 12" UNK SW IE=19.4CB TYPE 1 RIM=30.66 6" PVC NW IE=28.9 SDMH RIM=31.17 12" CONC(BROKEN) N IE=25.7 12" CONC E IE=25.6 SSMH RIM=30.43 UNKNOWN PIPE SIZE N & S IE=6.4 SSMH RIM=30.10 24" CONC W IE=19.4 24" CONC E IE=19.5 8" CONC S IE=20.7 SDMH RIM=30.55 18" CMP RISER N IE=21.0 24" CMP S IE=21.1 PPP PP P 6.5 ' W I F 6.5 ' W I F CW CW CG RC PECCCW WV CW CC PCW WM WVWV(4) CWEM ECB CGCG CGCCWV(3) WV CG CGCW CC PA CC CW CW CW CW CONC CC CONC DW CONCECCECCASPH DW CONC METAL GRATEECC6.5' WIF 6. 5 ' W I F 6. 5 ' W I F G A T E ICV(2) P PAPA CGCGCGPPECB(4) CONC WALLT PA CW GRASSWV WV CGCG AW CW CW 7' WIF7' WIF7.5' CLF W/ BW GATE PGAR GV7.5' CLF W/ BW6.5' WIF PA PATTTTTT CGTE TE EP EP DIT SSMH RIM=30.03 24" CONC W IE=20.6 12" DI N IE=21.3 18" CONC NE IE=20.6 24" CONC S IE=20.6 SSMH RIM=30.37 24" DI NW IE=20.1 24" CONC E IE=20.1 CB TYPE 2 SOLID LID RIM=29.17 24" DI W IE=19.2 24" CPP E IE=19.3 12" CPP SE IE=23.6 SDSD SD SDSD SD S D S D S D SDSD SD SDSDSD SD SD SD SDSD SD SSSSSD2" BRASS CAP W/ PUNCH IN CONC IN MONUMENT CASE 0.5' BELOW GRADE N: 182524.23 E: 1300730.89 1 1/2" BRASS CAP W/ PUNCH IN CONC IN MONUMENT CASE 0.5' BELOW GRADE N: 182524.26 E: 1300717.64SD SD SD 24" DI 24" CPP 24" CPP 24" CPP24" CPP24" CPP 24" CONC24" CPP24" CPP24" CONC 24" CONC 24" CONC18" CMP24" CMP24" CONC 24" DI 24" DI 24" CONC 24" CONCCWCW 6" STW HP 6" STWTJR ECC CW SSSS6" STW HP 6.5' WIF CW CG CG ASPH ASPH PA 6.5' WIF PA WWWW W W W W 2" BRASS CAP IN CONC IN MONUMENT CASE W/ PUNCH 0.8' BELOW GRADE N: 182522.62 E: 1300894.47 SDSDSSSD 24" CPP 24" CONC 18" CONC15" CONC 15" CONC 15" CONC 15" CONC24" CONC24" CONC24" CONC24" CONC 24" CPP24" CPP24" CPP R/W R/W30'52.5'VARIESR/W R/W30'VARIESR/W R/W30'VARIESR/WR/W60'54'R/W40.5'VARIES R/WR/W R/W VARIES29.9'SDMH RIM=31.06 15" CONC W IE=21.1 12" CONC NE IE=22.3 15" CONC E IE=21.1 12" CONC E IE=23.2 12" CONC S IE=23.3 R/W29.9'HAS A WV LID BUT MIGHT BE A GV NO PAINT NEARBY R/W30'30'R/WR/W30'SSMH RIM=30.60 24" CONC SW IE=19.3 24" CONC E IE=19.4 WM WV24" CPPCG6" STW HP D D D D DD D D D D D GV 737 LOGAN AVE N 0723059001 737 LOGAN AVE N 0723059001 737 LOGAN AVE N 0723059100 600 LOGAN AVE N 0886610020 660 LOGAN AVE N 7224500315 546 BURNETT AVE N 24" CONC 24" CONCS SCO S S D S 0723059100 600 LOGAN AVE N EAST LINE OF SE 1/4 OF SEC 07, T23N R4EWEST LINE OF SW 1/4 OF SEC 08, T23N R4EEAST LINE OF SE 1/4 OF SEC 07, T23N R4EWEST LINE OF SW 1/4 OF SEC 08, T23N R4EPLAN VIEW SCALE: 1"=20' Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: __________________________ Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr PC APPROVAL 4/6 J.MEANS 206-305-8570 N.HILL 925-450-3083 H.NGUYEN 303-788-9142 M.LOCK 425-424-6413 A.ALEXANDER 925-394-2228 B.JOHNSON 206-571-8519 6-13-24 N/A RENTON 2" MPE MAIN EXTENSION 737 N 6TH ST RENTON, WA 98057 PUGET SOUND ENERGY 109102766 109102766 1"=20' KING 498 PMPDPM13 SE 7-23-05 E / SW 8-23-05 E 204.080 207.081/207.082 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/AMATCHLINE B-BSHEET 5N 8TH ST MATCHLINE A-ASHEET 3LOGAN AVE NLOGAN AVE NBURNETT AVE NN 6TH ST (ARTERIAL) N 6TH ST N 5TH STN 4TH ST (ARTERIAL)(ARTERIAL)MFP25003634 TTTT 2" BRASS CAP IN CONC IN MONUMENT CASE W/ PUNCH 0.6' BELOW GRADE N: 182519.93 E: 1301179.29 G G G G G G G G G G P P P P P P P P P P P xx x x x x x x x x x x WWWGGGG G G G G G T T T T T T T T T T T CB TYPE 1 RIM=29.56 8" CONC N IE=26.4 8" CONC S IE=26.3 CB TYPE 1 RIM=29.39 8" PVC S IE=27.2 CB TYPE 2 SOLID LID RIM=30.84 8" CONC N IE=27.3 8" CMP SW IE=27.1 W/ FLOW RESISTOR CB TYPE 1 RIM=29.23 8" CONC NE IE=26.9 8" PVC S IE=26.8 SDMH RIM=30.19 24" CONC NW IE=20.4 24" CONC E IE=20.6 8" CONC S IE=25.5 SDMH RIM=29.85 24" CONC W IE=20.3 8" CONC NE IE=24.4 24" CONC SE IE=20.3 SSMH RIM=30.10 24" CONC W IE=19.4 24" CONC E IE=19.5 8" CONC S IE=20.7 PPA CC CW ASPH PARKING LOT GVL PARKING LOT GRASSCW CW CG CG CW CG GV CW CW PA 6.5' WIF6.5' WIF CW CW ICV(3) CONC PPA PA CC CONC DWECCCONC METAL GRATE 6.5' WIFECC SDSD SDSDSDSD SSGV(2) AW 24" CONC 24" CONC GVS 6" STW HP 2" STW IP 2" STW IP 6" STW HP ASPH DW DW DWDW T CONC WWWWW W W W W W W W W W W W W WV WV SDMH RIM=30.31 24" CONC W IE=20.8 24" CONC E IE=20.6 8" CONC NW IE=25.6 SDMH RIM=30.45 15" CONC W IE=22.1 15" CONC E IE=22.0 6" CONC S IE=24.1 6" CONC SE IE=27.3 CB TYPE 1 SOLID LID RIM=29.83 8" CONC N IE=27.1SDWV S D SDSDSDSDSD SD24" CONC 24" CONC 15" CONC 15" CONC15" CONC R/W30'R/W30'R/W30'R/W VARIESGRASS 36.2'R/W WV ECC R/W12'R/WWM W WV D D D D 546 BURNETT AVE N 7224500310 WILLIAMS AVE N 0886610020 660 LOGAN AVE N 24" CONC 24" CONC 24" CONC S Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: __________________________ Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr PC APPROVAL 5/6 J.MEANS 206-305-8570 N.HILL 925-450-3083 H.NGUYEN 303-788-9142 M.LOCK 425-424-6413 A.ALEXANDER 925-394-2228 B.JOHNSON 206-571-8519 6-13-24 N/A RENTON 2" MPE MAIN EXTENSION 737 N 6TH ST RENTON, WA 98057 PUGET SOUND ENERGY 109102766 109102766 1"=20' KING 498 PMPDPM13 SE 7-23-05 E / SW 8-23-05 E 204.080 207.081/207.082 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/AMATCHLINE B-BSHEET 41 WELLS AVE NWILLIAMS AVE NN 6TH ST (ARTERIAL) N 5TH ST IP GAS FLOW IP GAS FLOW Scale: N.T.S. TIE IN DETAIL1 MFP25003634 xxxxxxxxxxxxxUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTxxxxxxxxxxxxxxxxxGGGGGGGGGGGGGGGGGGGGGGGBLAST WALLCCCC WCR WCR IRC ICV (2)7' CLF W/ BW4' CLF4' CLF7' CLF W/ BW7' CLF W/ BW CW CW AW AW AW SD SD SD SD SD SD UTIL UTILUTILUTILCONC CONC UTIL CULVERT 4" PVC SW TOP OF PIPE=29.0 CULVERT 4" PVC SW TOP OF PIPE=29.0 CULVERT 4" PVC SW TOP OF PIPE=29.1 CULVERT 4" PVC SW TOP OF PIPE=29.2 CULVERT 4" PVC SW TOP OF PIPE=29.3 CULVERT 4" PVC SW TOP OF PIPE=29.0 BLAST WALLAPPROXIMATE LOCATION UN-OPENED R/W STATE RD. NO. 7 0723059001 0723059001 R/W 30'30'R/W R/W 30'30'0723059001 07230590013/4" STW3/4" STW4' CLF7' CLF W/ BW AW ASPH 4' CLF 737 LOGAN AVE N 737 LOGAN AVE N 737 LOGAN AVE N 737 LOGAN AVE N ASPH x xxxxW WGGGGGG GG7' CLF CULVERT 4" PVC SW TOP OF PIPE=29.1 CCFIRE STATION CO2 STORAGE TANK7' CLF W / BW SD SD CULVERT 4" PVC SW TOP OF PIPE=29.2 ASPH3/4" STW7' CLF W/ BWBLAST WALLGV UV LOOKS LIKE STORM FROM THE OUTSIDE SOLID LID UNKNOWN VALVE INSIDE3/4" STW ASPH RAMP (____)PEI800PLAN VIEW SCALE: 1"=20' Inspected Steel and PE pipe per GOS 2450.1400 and 2450.1500 Reviewed and complied with all construction notes. Recorded all required information on the as-built per GOS 2500.1700. Completed post installation inspection per GOS 2525.1200 and 2525.2700. Left the work area in a clean and safe condition. FITTER'S CHECKLIST Foreman's Name (printed) ___________________________________ Foreman's Signature________________________________________ Company: __________________________ Date ______________ (CHECK BOX TO CONFIRM COMPLETION) 4680 06/11 DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC OP MAP Emer Sect GAS WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY CP APPROVAL MAPPING SCALE PAGE ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE Drawing Number SAP Sup Order Nbr PC APPROVAL 6/6 J.MEANS 206-305-8570 N.HILL 925-450-3083 H.NGUYEN 303-788-9142 M.LOCK 425-424-6413 A.ALEXANDER 925-394-2228 B.JOHNSON 206-571-8519 6-13-24 N/A RENTON 2" MPE MAIN EXTENSION 737 N 6TH ST RENTON, WA 98057 PUGET SOUND ENERGY 109102766 109102766 1"=20' KING 498 PMPDPM13 SE 7-23-05 E / SW 8-23-05 E 204.080 207.081/207.082 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/APRIVATE ROADMATCHLINE D-D THIS SHEET MATCHLINE C-C SHEET 3 MATCHLINE D-D THIS SHEET PRIVATE ROADMFP25003634 BOM for WO: 109102766 ITEM QTY DESCRIPTION PART NO. 1 CAP 5/8" MECHANICAL 5200551 2 CP BOX TEST STATION COMPLETE PLASTIC 5000307 1 CAP 2" MDPE 5200649 4 ELBOW 2" X 90 MDPE 6000484 1127'PIPE 2" COIL MED DENSITY 7000261 1 CP COPPER ADAPTER SLEEVE 7600540 1 STOP-SHORT 2" X 150 PSIG, MUELLER H-17190 7600743 1 TEE-PUNCH, SERV 1/2" X 5/8" X 125 PSIG, PE OUTLET, 1/4" CUTTER 7800575 1 TRANSITION, 2" X 0.154" X SDR-11, GR B, WELD X FUSE 7800809 1 WELD METAL CATHODIC MOLD 8500080 10 CP WIRE #10 COPPER 8500930 1127'WIRE #14 COPPER TRACER 8500940 MFP25003634 P PPP PTPC 1/2" REBAR NO CAP 0.2' ABOVE GRADE xxxxxxxxUTUTUTUTUTUTUTUTUTUTxxxxxxxxxxxTUT PPPP FO FO FO FO x x FOFOFOFO FO FO FO P PPxx x SDMH RIM=26.1224" CIP E,W IE=18.5 SDMH RIM=28.35 8" RCP NW IE=22.924" CIP E,W IE=19.6 SDMH RIM=0.000" CONC E IE=0.0 CB TYPE 1RIM=25.84 12" CPP NW IE=21.9 CB TYPE 2 RIM=27.55 24" CIP E,W IE=19.1 CB RIM=0.00 0" CONC E IE=0.0 SSMH RIM=27.99 CANNOT ACCESSLID LOCKED 7' CLFPRIVATE ROADN 6TH ST 25 MPHPRIVATE ROADBLAST WALL CULVERT 4" PVC SW TOP OF PIPE=29.1 CCCCCCWCR WCR ROTATINGSECURITYGATE FIRE STATION CO2 STORAGE TANK7' CLF W/ BW IRC ICV (2)7' CLF W / BW4' CLF4' CLF4' CLF7' CLF W / BW7' CLF W/ BW15MPHCW CW AW AW AW AW AW CW 4' CLFCGWCR CW BUILDING 7' CLF W/ BW CC STOPSTOP CW CW 6' WIF 6' WIF ICV(2) ECB ICV 6' WIF6' W IF CULVERT12" CIP W TOP OF PIPE=27.5CULVERT 12" CIP E TOP OF PIPE=27.1 CULVERT12" CIP W TOP OF PIPE=25.0 WCR CW CCCCCONCSDSD CONC WALL W/ 7' CLF W/ BW 7' CLF W/ BW SD SD P P P PPA GVL GVLCONCGVL CONC PA GVL CONC UTIL UTILUTILUTILCONC CONC UTIL CULVERT4" PVC SW TOP OF PIPE=29.2 CULVERT4" PVC SW TOP OF PIPE=29.0 CULVERT 4" PVC SW TOP OF PIPE=29.0 CULVERT 4" PVC SW TOP OF PIPE=29.1 CULVERT4" PVC SW TOP OF PIPE=29.2 CULVERT 4" PVC SW TOP OF PIPE=29.3 CULVERT4" PVC SW TOP OF PIPE=29.0 ASPH ASPH ASPH PA PAPP CONC CONCPA CW EPEP PA DITCONC CGCGCGCG CGSTOPSTOPDIT CG CGCC WV WV(2) UTIL TOP OF DIT 7' CLF W/ BWBLAST WALLBLAST WALL7' CLF W / BW GV UV LOOKS LIKE STORMFROM THE OUTSIDESOLID LIDUNKNOWN VALVE INSIDE ASPH RAMP APPROXIMATE LOCATION UN-OPENED R/W STATE RD. NO. 7 R/W R/W30'32'30'R/W R/W30'33'30'R/W R/W30'33'0723059001 0723059001 0723059001 0723059001 0723059001 0723059001 0723059046 R/W R/W 30'30'R/W R/W 30'30'0723059001 0723059001 0723059046 PRIVATE ROADASPH CW CW CGCG W W W W W W W W 4' CLF7' CLF W / BW AW ASPH 24" CIP 24" CIP 24" CIP 24" CIP 24" CIP 24" CIP24" CIP 24" CIP BUILDING 4' CLF0723059046737 LOGAN AVE N 737 LOGAN AVE N 801 N RIVERSIDE DR737 LOGAN AVE N 737 LOGAN AVE N 737 LOGAN AVE N 737 LOGAN AVE N 737 LOGAN AVE N 737 LOGAN AVE N 801 N RIVERSIDE DR 801 N RIVERSIDE DR PA ASPH TJR GV S D SSS ICV DD SGM SS6" STW HP 6" STW HP 3/4" STW1" STW3/4" STW3/4 " STW3/4" STW3/4 " STW3/4" STW CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG RETIRE (2) HP SERVICES BOEING 5-27 & BOEING 5-28 737 N 6TH ST, RENTON 108653203 4D02-469 1/4 PLOT PLAN GAS MAIN PRESSURE AND TESTING REVISIONS FITTER'S CHECKLIST DRAWING SHEET INDEX SAP ORDER #108653203TYPE/ WORK PIPE SIZE TYPE EST LENGTH ACT LENGTH MANUFACTURER GAS MAIN INSTALLATION/RETIREMENT PROJECT CONTACT LIST FOR JOB#108653203 DETAIL SECTION DETAIL CALLOUT DETAIL LABEL SECTION CALLOUT SECTION LABEL PLAT MAP PRELIMINARY DRAWING REVIEW (60%) Changes NeededRoleName Engineer Blank Approving Engineer Cathodic Protection Pressure Control Construction Management Project Manager Gas System Integrity & Planning Industrial Meter Operations Instrumentation OK as Designed Date MFP25003634 CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG RETIRE (2) HP SERVICES BOEING 5-27 & BOEING 5-28 737 N 6TH ST, RENTON 108653203 4D02-469 2/4 GAS MAIN PRESSURE AND TESTING FITTER'S CHECKLIST WELDER REVISIONS NOTE S T O B E P R O VI D E D A T L A T E R D A T E MFP25003634 P P TPC xT T TUTUTUTUTUTUTWWPP P P P P PP FO FO FO FO FO FO FO FO x x x x FOFOFOFOFO SDMH RIM=26.12 24" CIP E,W IE=18.5 CB TYPE 1 RIM=25.84 12" CPP NW IE=21.9 ROTATING SECURITY GATE BUILDING CULVERT 12" CIP E TOP OF PIPE=27.1 CULVERT 12" CIP W TOP OF PIPE=25.0 CONC SD SD SD SD SD CONC WALL W/ 7' CLF W/ BW 7' CLF W/ BW SD P P P P P P P P P GVL GVLCONCGVL CONC PA GVL CONC DIT CGCC WV WV(2) UTIL R/W R/W30'32'30'0723059001 ASPH CW CW CGCG W W W W W W W W W 24" CIP 24" CIP 24" CIP 24" CIP BUILDING 0723059046801 N RIVERSIDE DR737 LOGAN AVE N PA TJR DD SGM SS6" STW HP 6" STW HP 3/4" STW6" STW HP CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG RETIRE (2) HP SERVICES BOEING 5-27 & BOEING 5-28 737 N 6TH ST, RENTON 108653203 4D02-469 4/4 GAS MAIN PRESSURE AND TESTING FITTER'S CHECKLIST REVISIONS PLAN VIEW - 1DETAIL MFP25003634 CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG RETIRE (2) HP SERVICES BOEING 5-27 & BOEING 5-28 737 N 6TH ST, RENTON 108653203 4D02-469 3/4 GAS MAIN PRESSURE AND TESTING FITTER'S CHECKLIST REVISIONS MFP25003634