Loading...
HomeMy WebLinkAbout305 RentonSH A T T U C K A V E S S 3RD STREET FRONT DOOR ENTRY BACKDOOR ENTRY WH I T W O R T H A V E S NO.DATE DESCRIPTION INTERIOR REMODEL TITLE: SCALE: SHEET: 4730 UNIVERSITY WAY NESTE 104 #111SEATTLE WA 98105 ALITTLECEDAR@GMAIL.COM LITTLECEDAR LITTLE CEDAR LLC. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENTMAY BE REPRODUCED ANY FORM OR BY ANY MEANS WITHOUTPERMISSION IN WRITING FROM LITTLE CEDAR LLC. 1" = 10'-0" A0.0 GENERAL NOTESAND SITE PLANS 305 RENTON TENANTIMPROVEMENT AREA OF WORK (INTERIOR WORK ONLY) PARCEL NUMBER: 784130-0020 ADDRESS: 305 S 3RD STREET RENTON WA 98057 SCOPE OF WORK: INTERIOR REMODEL IN THE EXISTING RETAIL SPACE. ADD SOUND INSULATION WALL INSIDE OF THE EXISTING WALL TO CONVERT THE SPACE TO BE A MULTI MEDIA ROOM. PROPERTY LEESE: HONGBIN LIN ZONING: CD EXISTING FINISHED AREA: 2,965 SF(1F)+200 SF (2F)= 3165 SF (NO CHANGE) NEW FINISHED AREA: 0 SF PROJECT INFORMATION LEGAL DESCRIPTION SHEET INDEX CODE CONFORMANCE ABBREVIATIONS GENERAL NOTES CONTRACTOR SHALL BE IN COMPLIANCE WITH ALL THE REQUIREMENT OF THE 2021 INTERNATIONAL BUILDING CODE, 2021 WASHINGTON ENERGY CODE, AND OTHER ALL APPLICABLE CODE. FEDERAL, STATE AND LOCAL CODE REQUIREMENTS SHALL TAKE PRECEDENCE OVER THIS DOCUMENT. CONTRACTOR IS SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITION OF THE JOB SITE, INCLUDING SAFETY, PROTECTION AND THE LINK DURING THE PERFORMANCE OF THE WORK. CONTRACTOR TO COORDINATE OWNER’S WORK, ITEMS SUPPLIED BY OWNER AND INSTALLED BY CONTRACTOR AND ITEMS NOT IN CONTRACTOR BUT ATTACHED TO CONTRACTOR ’S SCOPE. WHERE THERE ARE DISCREPANCIES AND CONFLICTS IN THE DRAWING SET, THE MOST STRINGENT REQUIREMENTS SHALL APPLY UNLESS DIRECTED OTHERWISE BY THE ARCHITECT. NO SCALE MEASUREMENT SHALL BE USED AS DIMENSION FOR WORK. COORDINATE ALL DISCREPANCIES IN DRAWINGS WITH OWNER AND ARCHITECT IMMEDIATELY PRIOR TO FABRICATION OR INSTALLATION. CONTRACTORS SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING WORK. EXISTING ELECTRICAL MECHANICAL & PLUMBING MAY REQUIRE RELOCATION, DEMOLITION, OR OTHER WORK, TO ACHIEVE THE DESIGN INTENT OF THE DRAWINGS. CONTRACTOR TO REVIEW WALL/ FLOOR ASSEMBLY AND LAYOUT WITH ARCHITECT PRIOR FRAMING. COORDINATE WITH STRUCTURAL SHEAR-WALL SCHEDULE AND ADD GYPSUM WALL BOARD AS NEEDED TO MATCH THICKNESS OF PLYWOOD SOF FLUSH FINISH SURFACE. CONTRACTOR SHALL REVIEW THE LATEST EDITION OF “FIRE RESISTIVE DESIGN MANUAL” BY THE GYPSUM ASSOCIATION ONSITE WHERE RATED ASSEMBLIES ARE REQUIRED. ARCHITECTURAL DRAWINGS ARE TO CONVEY ARCHITECTURAL INTENTS ONLY. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. INSTALL ALL ELECTRICAL FIXTURES & DEVICES IN ACCORDANCE WITH THE LATEST EDITIONS OF THE NEC, IBC AND WAC. CLEAN, PATCH AND REFINISH EXISTING WALLS SCHEDULED TO REMAIN AFTER DEMOLITION. PLUMBING SYSTEMS: FURNISH SEPARATE FEES AND PERMIT FOR DEFERRED PERMIT SUBMITTAL. ALL WATER HEATER PRESSURE RELIEF VALVES AND DRIP PAN OVERFLOWS TO BE HARD PIPED TO SEWER SYSTEM OR TERMINATE AT EXTERIOR GRADE PER CODE. MECHANICAL SYSTEMS: FURNISH SEPARATE FEES AND PERMIT FOR DEFERRED PERMIT SUBMITTAL. CONFIRM FINAL LOCATION OF ALL MECHANICAL EQUIPMENT (INDOOR AND OUTDOOR) WITH OWNER PRIOR TO INSTALL. ELECTRICAL SYSTEMS: FURNISH SEPARATE FEES AND PERMIT FOR DEFERRED PERMIT SUBMITTAL. FURNISH AND INSTALL ALL CONDUCTOR, DISCONNECTS AND DEVICES FOR HVAC SYSTEMS. CONFIRM FINAL LOCATION OF ALL DEVICES, FIXTURES AND OUTLETS WITH OWNER PRIOR TO ROUGH-IN. EMERGENCY AND ALARM DEVICES PER FLOOR PLAN LAYOUT ARE SHOWN FOR ARCHITECTURAL DESIGN AND EGRESS CODE REVIEW BY BUILDING OFFICIAL. FINAL LAYOUT, LOCATION AND QUANTITY TO BE DETERMINED BY AUTHORITY HAVING JURISDICTION FOR CODE COMPLIANCE AND ENFORCEMENT. CONTRACTOR SHALL FIELD COORDINATE WITH SHOP DRAWING SUBMITTAL AND AUTHORITY HAVING JURISDICTION INSPECTIONS. ALL DOORS ARE DIMENSIONED TO FINISH DOOR SIZE, NOT INCLUDING ROUGH - IN OR JAMB. STRUCTURAL ELEMENTS AND GRADES AS SHOWN IN ARCHITECTURAL DRAWINGS ARE FOR DESIGN INTENT ONLY. ALL STRUCTURAL SIZE, FOOTING DEPTHS, AND GRADES ARE SUBJECT TO CHANGE PER STRUCTURAL/CIVIL DRAWINGS, GEOTECHNICAL REPORT AND ACTUAL FIELD CONDITION. A0.0 GENERAL NOTES AND SITE PLAN A1.1 FLOOR PLANS SMITHERS 5TH ADD TO RENTON PLAT BLOCK: 1 PLAT LOT: 4-5-6 2021 INTERNATIONAL BUILDING CODE WITH STATEWIDE AND CITY AMENDMENTS ABV ABOVE BLK'G BLOCKING BI BIFOLDING FLOOR C CENTER LINE CLR CLEAR CONT CONTINUOUS CS CASEMENT WINDOW DBL DOUBLE DS DOWNSPOUT EL ELEVATION EQ EQUAL (E) EXISTING GC GENERAL CONTRACTOR GWB GYPSUM WALL BOARD FTG FOOTING FX FIXED WINDOW HDR HEADER HDWD HARDWOOD HGR HANGER HORIZ HORIZONTAL MAX MAXIMUM MFR MANUFACTURER MIN MINIMUM o/ OVER O.C. ON CENTER SD SMOKE DETECTOR SG SAFETY GLASS SGL-HG SINGLE- HUNG WINDOW SF SQUARE FEET SIM SIMILAR SLD SLIDING WINDOW PT POCKET DOOR PR PAIR DOOR TYP TYPICAL UNO UNLESS NOTED OTHERWISE VIF VERIFY IN FIELD W/ WITH 1" = 10'-0"11 SITE PLANSITE PLAN 305 S 3RD ST RENTON WA 98057 08/05/2025 PERMIT SUBMITTAL 305 PROJECT NAME: 305 RENTON TENANT IMPROVEMENT SIZE OF EXISTING SPACE: 3165 SQ FT SIZE OF WORK AREA: 485 SQ FT LOCATION OF SITE: 305 S 3RD STREET ZONING DESIGNATION : CD CURRENT USE OF THE SITE AND ANY EXISTING IMPROVEMENTS: VACANT RETAIL SPACE SPECIAL SITE FEATURES: NONE STATEMENT ADDRESSING SOIL TYPE AND DRAINAGE CONDITIONS: NONE; THE SCOPE OF WORK IS ALL INTERIOR PROPOSED USE OF THE PROPERTY AND SCOPE OF THE PROPOSED DEVELOPMENT : BUSINESS; REMODEL EXISTING ROOM TO MULTI MEDIA ROOM PROPOSED OFF-SITE IMPROVEMENTS: NONE TOTAL ESTIMATED CONSTRUCTION COST AND ESTIMATED FAIR MARKET VALUE OF THE PROPOSED PROJECT: $ 10,000 ESTIMATED QUANTITIES AND TYPE OF MATERIALS INVOLVED IF ANY FILL OR EXCAVATION IS PROPOSED: N/A NUMBER, TYPE AND SIZE OF TREES TO BE REMOVED: N/A PROJECT NARRATIVE UP (E)KITCHEN (E)TOILET (E)TOILET (E)SAUNA (E)STORAGE (E)OPEN SPACE MULTI MEDIA ROOM INSTALL SOUND INSULATION WALL AROUND THE EXISTING WALL (E)BATH (E)DINING (E)CABINET (E)STEP (E)COLUMNS TO REMAIN NEW DEMOLISH EXISTING PLAN LEGENDPLAN LEGEND EXISTING; NOT IN SCOPE OF WORK 1. USE CONVENTIONAL FRAMING AND SHEATHGIN U.N.O. 2. ALL EXTERIOR WALLS TO BE 2X6 FRAMING U.N.O. 3. ALL INTERIOR WALLS TO BE 2X4 FRAMING U.N.O. 4. ALL DOOR JAMBS TO BE SET OFF WALLS WALLS 6" TYP. U.N.O. 5. ALL DIMENSIONS ARE TO FACE OF FRAMING U.N.O. 6. ALL EXHUST FANS ARE TO VENTED TO OUTSIDE. PLAN NOTESPLAN NOTES 7. DOOR HT. AT THIS FLOOR IS 6'-8", TYP. 8. ALL SMOKE DETECTORS MUST BE PROVIDED W/ PRIMARY POWER FROM BUILDING WIRING, PROVIDED W/ BATTERY BACKUP, AND BE INTERCONNECTED. 9. CEILING HEIGHT TO ALIGN WITH EXISTING 10. ESCAPE (EGRESS) WINDOW MUST HAVE A CLEAR OPENABLE AREA OF 5.7 S.F. W/ A MINIMUM NET CLEAR HEIGHT OF 24" AND WIDTH DIMENSION OF 20". THE SILL HEIGHT MUST NOT BE MORE THAN 44" ABOVE THE FLOOR. 11. ALL EXTERIOR COLUMNS, BEAMS AND JOISTS ARE EXPOSED TO THE WEATHER MUST BE PRESSURE - TREATED. 12. EXISTING CEILING, WALL OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION SHALL BE FILLED WITH INSULATION. 2X4 FRAMED WALLS SHALL BE INSULATED TO BE INSULATED TO A MINIMUM OF R-15 AND 2X6 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OF R-21. 13. ALL NEW PERMANENTLY INSTALLED LIGHTING FIXTURES, EXCLUDING KITCHEN APPLIANCE LIGHTING FIXTURES, SHALL CONTAIN ONLY HIGH EFFICACY LIGHT SOURCES. 14. KITCHEN, BATHROOM, AND LAUNDRY EXHAUST TERMINATIONS TO EXIT THE STRUCTURE NOT LESS THAN 3 FEET FROM PROPERTY LINES, 3 FEET FROM OPERABLE OPENINGS INTO THE BUILDING AND 10 FEET FROM MECHANICAL AIR INTAKE CONTRACTOR TO VERIFY ALL OF EXISTING CONDITIONS PRIOR TO CONSTRUCTION. REPORT ARCHITECT FOR ANY DISCPRANCIES FUND. (E) ATTIC (NO CHANGE) NO.DATE DESCRIPTION INTERIOR REMODEL TITLE: SCALE: SHEET: 4730 UNIVERSITY WAY NESTE 104 #111SEATTLE WA 98105 ALITTLECEDAR@GMAIL.COM LITTLECEDAR LITTLE CEDAR LLC. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENTMAY BE REPRODUCED ANY FORM OR BY ANY MEANS WITHOUTPERMISSION IN WRITING FROM LITTLE CEDAR LLC. As indicated A1.1 FLOOR PLANS 305 RENTON TENANTIMPROVEMENT 1/4" = 1'-0"11 F1 FLOOR PLANF1 FLOOR PLAN 22 F2 FLOOR PLANF2 FLOOR PLAN 06/12/2025 STFI PERMIT SUBMITTAL 539 26TH AVE S SEATTLE WA 98144 AREA OF WORK (INTERIOR WORK ONLY) (E)FRONT DOOR ENTRY (E)BACK DOOR ENTRY (E)STAIR TO ATTIC 08/05/2025 PERMIT SUBMITTAL