HomeMy WebLinkAboutMFP25003894.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP25003894
IVR Number: 25003894
Permit Information
Permit Name: Puget Sound Energy - Electric
186069496- ENGR1 COMCAST TK#6585566Address/Location:08/01/2025Application Date:6197800025Parcel Number: 18408 116TH AVE SE
Permit Type:08/18/2025Issue Date:Franchise
Permit Work Class:08/18/2026Expiration Date:Major Utility
Job Number: 186069496Franchise Type:Electric
Description: Puget Sound Energy Electric CREW TO REPLACE 5 POLES @ GRIDS 316260 166558; 316252 166558; 316231
166558; 316208 166538 & 316178 166556. RAISE UNDERBUILD AND DISTRIBUTION @ GRIDS 316245 166557 &
316206 166557. TREE TRIMMING REQUIRED TO BE COMPLETED AS WELL. NO HS RESTORATION ANTICIPATED.
Contacts
Name Address PhoneTypeBilling
Katie Zimmerman
Puget Sound Energy
1660 Park Lane
Burlington, WA 98233
B: (425) 620-6742
C: (425) 620-6742
ApplicantX
Permits Central 355 110th Ave NE
Bellevue, WA 98004
B: (425) 620-6742
H: (425) 620-6742
C: (425) 620-6742
Contact
Vicki Henson
Potelco Inc
8001 212th St S
Kent, WA 98032
B: (253) 863-0484Contractor
Business License Number: 5109Electrical Contractor: POTELI*344O4
Construction Contractor: POTELI*227PL
Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08
Bellevue, WA 98009
B: (888) 225-5773Emergency
Contact
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Katie Zimmerman
Puget Sound Energy
1660 Park Lane
Burlington, WA 98233
B: (425) 620-6742
C: (425) 620-6742
Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
PUBLIC WORKS DEPARTMENT
Page 1 of 6 | Published: 2/25/2025
Transportation Systems Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 2/25/2025
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK AND FOR TRAFFIC SIGNAL
WORK WITHIN 150 FEET OF THE INTERSECTION AT LEAST FIFTEEN (15) WORKING DAYS BEFORE THE DATE OF WORK.
FOR PURPOSES OF THIS APPLICATION, WORKING DAYS ARE DEFINED AS MONDAY THRU FRIDAY, AND EXCLUDING
CITY HOLIDAYS.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a Traffic
Control Plan (TCP) and obtain City's approval of that plan when construction, repair, or maintenance work is to be
conducted within the City's right-of-way.
1.Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2.All TCPs must conform to all attached requirements. Failure to do so may be subject to resubmittal.
3.Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
4.Resubmittal may be required for TCPs that are incomplete and do not display proper requirements as
described in the guidelines. Additional review time may be needed.
By signing, I certify that the information on this application and within the submittal documents are accurate to the
best of my knowledge and I acknowledge and have read all the requirements and guidelines on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip: ___________
Description of Work:
24 Hour Emergency
Contact Name & Phone:
Approval By: ______________________________________________ Date:____________________
PW/Transportation or CED/Development Engineering Division
Potelco, Inc
6905 S 228th St Kent, WA 98466
Please See Attached
Katie Zimmerman
8/1/2025
186069496- ENGR1 COMCAST TK#6585566
18408 116TH AVE SE
BLAKE JOHNSON 253-553-6882
Monday Friday 3:00pm
Scott Warlick CED 8/18/2025
MFP25003894
9:00am
Page 2 of 6 | Published: 2/25/2025
This Page Intentionally Left Blank
Page 3 of 6 | Published: 2/25/2025
APPLICANT AGREES TO ALL THE FOLLOWING REQUIREMENTS:
GENERAL
• Applicant is responsible for compliance with all traffic regulations of the City of Renton (City) and the State
of Washington, including codes and regulations not described in this application.
• Work Zone Traffic Control shall be in accordance with Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to Washington State Department of Transportation
(WSDOT) traffic control plans.
• Any lane or street closures not in conformance with the approved Traffic Control Plan (TCP) and/or without
notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs
or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable
State and City codes.
• Indemnify and hold harmless the City from any and all claims, actions, and judgments, including all costs of
defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved TCPs including claims arising from towing of private vehicles and the acts
of Applicant’s agents and employees.
• Applicant must comply with all conditions of the application.
• The City shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such
event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this application, Applicant is
responsible to pay for legal counsel chosen by the City to defend against same.
• No more than one TCP shall be in use at any given time for a single project. If multiple TCPs are submitted
for review and approval at the same time, the TCPs shall be clearly labeled as separate plans and include
construction phasing and sequencing.
• Previously approved TCPs cannot be combined into a new TCP without review and approval by the City.
• Expired TCP is not valid and shall not be used. Applicant shall resubmit the expired TCP for approval with
the updated date and time and/or any changes to TCP.
• Applicant must have the approved TCP prior to commencing the work.
• Approved TCP must be at the work site during work hours.
• Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or
slippery road conditions during work and non-work hours.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number
at a conspicuous place on the vehicle or equipment.
• At signalized intersections, vehicle detection shall always remain operational, unless approved in this TCP
and notified Transportation Signal Maintenance prior to commencing work. If damage occurs to existing
vehicle detection that is to remain, it is Applicant’s responsibility to replace with video vehicle detection
equipment that meets current City’s standards at Applicant’s expense.
• When not in use, temporary traffic control devices shall be removed or covered immediately. It is the
Applicant’s responsible to cover any temporary traffic control devices when not applicable for the
construction activities. Similarly, when work is suspended for short periods of time, traffic control devices
that are no longer necessary shall be removed or covered. If deemed abandoned, City crews will remove
and may store them at the City’s maintenance shop (3555 NE 2nd Street) for up to sixty (60) days. The City
is not responsible for any private property from City assets and identifying the property owner.
• Applicant is responsible to maintain existing pedestrian accessible routes during work and non-work hours.
At intersections, the work on pedestrian facilities shall be limited to one (1) corner at a time, with the least
possible inconvenience or delay to pedestrians. Pedestrian pushbuttons shall remain accessible at all times,
unless approved pedestrian accessible detour(s) are provided. Accessibility to existing or temporary
Page 4 of 6 | Published: 2/25/2025
pedestrian pushbuttons shall not be impaired. Deficiencies caused by Applicant’s operations shall be
repaired at Applicant’s expense.
• Applicant shall provide complete assistance and accommodation from a dedicated pedestrian escort to all
kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a
work zone.
• Driveway and alley access shall be maintained at all times, also see RMC Chapters 9 and 10 for Street
Closure and Street Excavation for details. Applicant is responsible for coordinating with the property
owners and/or residents prior to commencement of the work.
• Pavement excavation shall be limited to a maximum of one travel lane at a time unless otherwise
approved.
• Accessibility for emergency vehicles shall be maintained at all times.
PUBLIC OUTREACH
• Applicant must notify Transportation Signal Maintenance (425-430-7423) and City inspector (425-430-
7203) at least twenty-four (24) hours before commencing work (lane shift/closure or near a signal)
affecting the vehicle detection.
• Applicant shall notify emergency services (253-852-2121) twenty-four (24) hours before any street closures
or lane closures.
• Applicant shall call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five (5) working days (excluding
weekends and holidays) prior to starting any work.
• Applicant shall coordinate with King County Metro Transit Construction Information Center (206-477-1140
or construction.coord@kingcounty.gov) for any construction or installation activities affecting transit
operations or facilities. Notification information and guidelines can be found at:
https://kingcounty.gov/en/dept/metro/about/contractor-resources/transit-system-impacts.
WORKING DAYS AND TIMES
• Normal working days are Monday through Friday. Work on holidays, weekends or at night shall not occur
without City’s approval. For work times between 10:00 p.m. and 7:00 a.m., see Night Work section below
for details.
• Work time begins when any street or travel lane is fully or partially closed. This includes set up and removal
within the traveled way.
• If the City determines the closure hours adversely affect traffic during the work, the City may require to
adjust or reduce the working hours accordingly. Reduced work hours may be required by the City to
minimize traffic impacts for any work located near a school during pick-up and drop-off times or on an
arterial street. (See WSDOT Functional Classification Map:
https://www.wsdot.wa.gov/data/tools/geoportal/?config=FunctionalClass)
• Applicant may request the City for consideration of extended or modified working hours. Such request
must be approved by the City before changing hours of work.
CLOSURES
• All closure hours and days are subject to local permit and ordinance conditions (such as noise ordinances).
More information can be found on https://www.rentonwa.gov/City-Services/Permit-Center. Total street
closure lasting more than twenty-four (24) hours is subject to City Council authorization per Section 9-9 of
the Renton Municipal Code (RMC).
• Road closure notice – Applicant must install Portable Changeable Message Sign (PCMS) boards no less than
five (5) working days in advance of effective date and time, not including holidays, at location(s) as
identified in the TCP. Other methods of displaying the messages shall be approved by the City.
Page 5 of 6 | Published: 2/25/2025
• Road closure notice messages must include at least the following:
ROAD WILL BE CLOSED
MONTH/DAY – MONTH/DAY
_AM - _PM
• Road and/or sidewalk closure must be evaluated by the City with respect to both the necessity as well as
the impact of the closure to the public. Applicant shall submit detour plans for road closures to
accommodate both motorized and non-motorized users, including accessible pedestrian route(s). Road
closures shall require additional temporary traffic control including advance notification, approach and
detour signage.
• Applicant is responsible to temporarily remove the flags and install bags over the flag holders for any work
requiring the temporary closure of a crosswalk equipped with pedestrian flags. Applicant shall ensure the
bags remain intact and shall replace damaged bags as needed or determined necessary by the City of
Renton inspector. For any misplaced or lost flags, Applicant is responsible to replace at Applicant’s own
expense. Upon restoration of the crosswalk, Applicant shall remove the bags and return all flags to the
holders. Inventory of pedestrian flags must be submitted to the City inspector and reported to City of
Renton Transportation Signal Maintenance (425-430-7423) prior to removal.
UNIFORMED POLICE OFFICERS (UPO) / FLAGGERS
• Any construction activities within one hundred and fifty (150) feet of a signalized intersection shall require
Uniformed Police Officer(s) (UPO) at the traffic signal, unless otherwise approved in this TCP and evaluated
by City Transportation for the impacts of traffic signal operations and safety.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic
or pedestrian safety or travel.
• For TCPs that require the presence of UPO to manage vehicular traffic and pedestrians at signalized
intersections, Applicant shall coordinate with Transportation Signal Maintenance (425-430-7423) at least
twenty-four (24) hours in advance for any signal that will be placed in red flashing mode. Applicant shall
notify Transportation Signal Maintenance when the intersection is back to the normal traffic signal
operations.
TEMPORARY TRAFFIC SIGNALS OR TRAFFIC SIGNAL MODIFICATION
• Temporary traffic signal programming or modification requires a minimum fifteen (15) working days for
each traffic signal controller to be programmed and tested by City Transportation staff before starting the
work. The Start Date on this TCP shall reflect the time for temporary traffic signal programming or
modification.
TEMPORARY NO-PARKING
• Applicant must post notice of date(s) and time(s) of Temporary No Parking Zone with signs at every
hundred (100) feet at least seventy-two (72) hours in advance of effective date and time.
• Applicant is responsible to show on the TCP the limits of Temporary No Parking Zone, identifying barricade
locations for vacate parking or curb lane usage. The cover sheet of this approved TCP form must be
attached to each Temporary No Parking Sign on the project site.
• Two travel lanes (one for each approach) must be open at all times on arterial streets unless approved in
this TCP.
NIGHT WORK
• Between the hours of 10 p.m. and 7 a.m., approved Noise Variance shall be required (See Section RMC 8-7-
8) for night work. Process may take up to twelve (12) weeks. More information can be found at
https://www.rentonwa.gov/City-Services/Permit-Center/Land-Use-Development/Noise-Variance.
• City may require night work for TCPs that have severe traffic impacts on arterial streets.
Page 6 of 6 | Published: 2/25/2025
• Night work shall always be required if two lanes of traffic (One for each approach) cannot be maintained
on an arterial street.
• Night work shall be required if an evaluation of existing traffic volumes and patterns finds that any TCP will
functionally reduce an arterial or high-volume collector street to only one lane of traffic.
• The following configurations may require night work:
Work at traffic signals that requires shifting one direction of traffic into a left turn pocket where a high
volume of left turns occur.
Work at traffic signals that requires shifting two directions of traffic into left turn pockets.
Work at traffic signals that requires shifting high-volume left-turn movement into a through lane on a
single approach to the intersection.
Work at signals that requires shifting left-turning traffic into a through lane on multiple approaches to
the intersection.
• If City’s initial TCP review finds that night work is required, a pre-construction meeting is mandatory to
confirm the extents of the work required, the duration of work, anticipated noise levels, and any potential
alternatives to mitigate the impact of night work to adjacent residents prior to review and approval of the
TCP.
TRAFFIC CONTROL PLAN (TCP) FORMAT
• TCP must be site and project specific. The TCP shall clearly indicate all existing transportation facilities
impacted by work including roads, bike lanes, sidewalks, transit stops, and driveways. Typical drawings,
taper tables and MUTCD illustrations, by themselves, are insufficient.
• Each construction phase shall be provided with appropriate work zone traffic control. The impacts of utility
relocation, traffic delays, detours and capacity restrictions must be considered and addressed. A suitable
sequence of construction activities must be discussed with City Staff prior to fully developing TCPs based on
the complexity of a project.
• TCPs shall be clearly labeled as separate plans to identify the construction sequencing during each phase
when more than one TCP layout is submitted.
• TCP must be submitted with an electronic copy of TCP layout(s), on 11” X 17” paper size PDF format, which
consist of:
Map(s) showing the location of the project and work area.
All fonts shall be legible and a minimum 10-point font size.
All symbols of viewing or printing shall be clear and contrasting.
All streets shall be labeled, and layout must include a north arrow and scale.
Must show channelizing devices, signing, flagger locations, barricades, PCMS boards, etc.
Show locations where the standard traffic control plans are applied.
18408P01W20-1ROAD
WORK
AHEAD W20-4ONE LANE
ROADAHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AX'≥X'≥W20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7ASTOP
STOP
STOP
1111551010SE 184TH STSE 184TH ST115TH PL SE
116TH AVE SE1212STOPSTOPW20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7ANSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Project Address:PagePSEPUGETSOUNDENERGYContact:Job #REVJohn Crofoot425-424-6658John.Crofoot@pse.com1 OF 6 18408 116TH AVE SE, RENTON, WA0 51591277607/16/2025Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flaggers shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOP
POLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:John CrofootCard No. 012613Card Exp. 10/31/24John.Crofoot@pse.com(425)424-6658W20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥X'≥FROMTOTOW AWAY AREAPHONE 684-5444NAME OF FIRM XXX-XXX-XXXXNO PARKINGRESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSUREW20-7A
3XJHW6RXQG(QHUJ\7UDIILF&RQWURO6XSHUYLVRU˛-RKQ&URIRRW&DUG1R,6ˇˆ&DUG([S˙-RKQ&URIRRW#SVHFRP˘ˇˇ˘˙MFP25003894
18408
P02
P03W20-1ROAD
WORK
AHEAD
BE
PREPARED
TO
STOP W3-4STOP
STOP 111155SE 184TH ST
SE 184TH ST
115TH PL SE116TH AVE SE1212W20-1ROAD
WORK
AHEAD W20-4ONE LANE
ROAD
AHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADBEPREPAREDTOSTOPW3-4X'≥X'≥
W20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥N
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Project Address:
Page
PSE PUGET
SOUND
ENERGY
Contact:
Job #
REV
John Crofoot
425-424-6658
John.Crofoot@pse.com
2 OF 6 18408 116TH AVE SE, RENTON, WA
0
515912776
07/16/2025
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
POLE
TEMPORARY TRAFFIC CONTROL PLAN
W20-7A1010
Puget Sound Energy
Traffic Control Supervisor:
John Crofoot
Card No. 012613
Card Exp. 10/31/24
John.Crofoot@pse.com
(425)424-66581010FROMTOTOW AWAY AREAPHONE 684-5444NAME OF FIRM XXX-XXX-XXXXNO PARKINGRESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSUREW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥3XJHW6RXQG(QHUJ\
7UDIILF&RQWURO6XSHUYLVRU˛
-RKQ&URIRRW
&DUG1R,6ˇˆ
&DUG([S˙-RKQ&URIRRW#SVHFRP˘ˇˇ˘˙
MFP25003894
18408
P04115TH PL SE1212W20-7AW20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥SE 186TH ST STOPN
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Project Address:
Page
PSE PUGET
SOUND
ENERGY
Contact:
Job #
REV
John Crofoot
425-424-6658
John.Crofoot@pse.com
3 OF 6 18408 116TH AVE SE, RENTON, WA
0
515912776
07/16/2025
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
POLE
TEMPORARY TRAFFIC CONTROL PLAN
W20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7AW20-1ROAD
WORK
AHEAD W20-4ONE LANE
ROAD
AHEADX'≥X'≥116TH AVE SEPuget Sound Energy
Traffic Control Supervisor:
John Crofoot
Card No. 012613
Card Exp. 10/31/24
John.Crofoot@pse.com
(425)424-6658STOPRESIDENT(S) WILL BE INFORMED OF
TEMPORARY DRIVEWAY CLOSURE
12121010FROMTOTOW AWAY AREAPHONE 684-5444NAME OF FIRM XXX-XXX-XXXXNO PARKING1010
3XJHW6RXQG(QHUJ\7UDIILF&RQWURO6XSHUYLVRU˛
-RKQ&URIRRW
&DUG1R,6ˇˆ
&DUG([S˙
-RKQ&URIRRW#SVHFRP
˘ˇˇ˘˙
MFP25003894
P05
W20-1ROAD
WORK
AHEAD W20-4ONE LANE
ROAD
AHEADX'≥X'≥W20-7A116TH AVE SEW20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥W20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7ASTOP
STOP
1010
1010SE 186TH ST
101014N
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Project Address:
Page
PSE PUGET
SOUND
ENERGY
Contact:
Job #
REV
John Crofoot
425-424-6658
John.Crofoot@pse.com
4 OF 6 18408 116TH AVE SE, RENTON, WA
0
515912776
07/16/2025
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
POLE
TEMPORARY TRAFFIC CONTROL PLAN
W20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7APuget Sound Energy
Traffic Control Supervisor:
John Crofoot
Card No. 012613
Card Exp. 10/31/24
John.Crofoot@pse.com
(425)424-6658STOPSE 186TH PL1212
10103XJHW6RXQG(QHUJ\
7UDIILF&RQWURO6XSHUYLVRU˛
-RKQ&URIRRW
&DUG1R,6ˇˆ
&DUG([S˙-RKQ&URIRRW#SVHFRP˘ˇˇ˘˙
MFP25003894
P06W20-1ROADWORKAHEADX'≥X'≥X'≥W20-7AW20-4ONE LANEROADAHEADW20-1ROADWORKAHEADX'≥X'≥BEPREPAREDTOSTOPW3-4W20-1ROADWORKAHEAD X'≥X'≥BEPREPAREDTOSTOPW3-4 SE 186TH ST116TH AVE SE1010Project Address:PagePSEPUGETSOUNDENERGYContact:Job #REVJohn Crofoot425-424-6658John.Crofoot@pse.com5 OF 6 18408 116TH AVE SE, RENTON, WA0 51591277607/16/2025NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flaggers shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPPOLEMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:John CrofootCard No. 012613Card Exp. 10/31/24John.Crofoot@pse.com(425)424-6658RESIDENT(S) WILL BE INFORMED OFTEMPORARY DRIVEWAY CLOSUREW20-7ASTOPFROMTOTOW AWAY AREAPHONE 684-5444NAME OF FIRM XXX-XXX-XXXXNO PARKINGPLACE SIGNS BOTHSIDES OF WORK AREASTOP
10101212
3XJHW6RXQG(QHUJ\7UDIILF&RQWURO6XSHUYLVRU˛-RKQ&URIRRW&DUG1R,6ˇˆ&DUG([S˙-RKQ&URIRRW#SVHFRP˘ˇˇ˘˙MFP25003894
P07
SE 186TH PL
1010116TH AVE SE14N
SIGN SPACING
MPH
60/65
45/55
35/40
30
25
"X"
1000'
500'
350'
200'
100'
CHANNELIZATION
DEVICE SPACING
MPH
55/70
35/45
25/30
TAPER
40
30
20
TANGENT
80
60
40
Project Address:
Page
PSE PUGET
SOUND
ENERGY
Contact:
Job #
REV
John Crofoot
425-424-6658
John.Crofoot@pse.com
6 OF 6 18408 116TH AVE SE, RENTON, WA
0
515912776
07/16/2025
Notes:
1. All signs and spacing to conform to the
MUTCD and City of Renton standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated,
if indicated use ADA compliant channelization.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and
shall not obstruct pedestrian access.
5. Crew is required to leave a minimum of 10' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place during approved work hours as
per jurisdictional requirements. (Generally between 9
a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3
p.m. on arterials. If night time work is approved,
signaling and flaggers shall conform to WAC
296-155-305. Night time work to take place between
_____________and ______________.)
8. All Flagger and Downstream tapers shall be 50'-100'.
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
10
11
12
20
70
75
80
25
105
115
125
30
150
165
180
35
205
225
245
40
270
295
320
45
475
495
540
POSTED SPEED (MPH)
50
500
550
600
55
550
605
660
60
-
660
720
65
-
-
780
70
-
-
840
LEGEND
28" TRAFFIC CONE
SIGN LOCATION
TRAFFIC FLOW
WORK VEHICLE/
FLASHING LIGHTS
RIGHT OF WAY
WORK AREA
CHEVRON
ARROW BOARD
FLAGGER
UNIFORMED
POLICE OFFICERPOLICE
STOP
POLE
TEMPORARY TRAFFIC CONTROL PLAN
1010
W20-1ROADWORKAHEAD BEPREPAREDTOSTOPW3-4X'≥X'≥X'≥W20-7AW20-1ROAD
WORK
AHEAD W20-4ONE LANE
ROAD
AHEADX'≥X'≥X'≥W20-7AW20-1ROADWORKAHEADW20-4ONE LANEROADAHEADX'≥X'≥X'≥W20-7APuget Sound Energy
Traffic Control Supervisor:
John Crofoot
Card No. 012613
Card Exp. 10/31/24
John.Crofoot@pse.com
(425)424-6658STOPSTOPSTOPFROMTOTOW AWAY AREAPHONE 684-5444NAME OF FIRM XXX-XXX-XXXXNO PARKING10103XJHW6RXQG(QHUJ\
7UDIILF&RQWURO6XSHUYLVRU˛-RKQ&URIRRW&DUG1R,6ˇˆ&DUG([S˙-RKQ&URIRRW#SVHFRP
˘ˇˇ˘˙
MFP25003894
SE 184TH ST116TH AVE SE '18408'116TH AVE SESE 186TH ST'18434''18626'SE 186TH PL'11443''18418'115TH PL SETREETRIMMINGREQ'D515912776186069496101184907/108163177PROJECT PHASEPWRNOTIF#ORDER#SuperiorSub OrderN/AN/ATHIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIESCALL (800) 424-55552 BUSINESS DAYS BEFORE YOU DIGSAP W.O. #186069496FOREMAN (CHECK BOX WHEN COMPLETED)PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.Grid, Cable, and Switch numbers INSTALLED & VERIFIED.Field Changes RED-LINED on As-built.Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.Foreman's Signature _______________________________________________Print Name ___________________________________ Date ______________Material VERIFIED and CHANGES noted on Paperwork.Total PRIMARY Cable noted on As-built.Company ID#'s RECORDED in correct location on As-built.Deviations noted on the As-built and their reason.I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met.OH CIRCUIT MAP: D2305E136 SCALE 6" = 1 MILEARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSIONSTRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.)EROSION & SEDIMENT CONTROL REQUIREMENTSNOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES(LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROLEROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE& ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS.POWER GENERAL NOTES1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from thiswork sketch must be AUTHORIZED by Potelco's Project Manager and NOTED on the Foremans' Copy.2.All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three(3) working days in advance.3.Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing workto get the underground facilities located.4.All work is to be done in accordance with local municipal and county permit requirements as applicable.5.Inclement weather conditions may cause delays in construction times and dates.VICINITY MAPSITE SPECIFIC NOTESP01 (316260-166558)-REPLACE EXIST 40' POLE-INST 50' CL1 POLE (6010.1000 PD501)-CREW TO DEEP SET 2'-6"-INST 3Ø PRI NEUT DBL DE (6033.3064 DDEP313)-EXTEND 397.5MCMAAC PRI AS NEEDED (_____')-EXTEND 4/0 NEUT AS NEEDED (_____')-INST 2Ø PRI NEUT DE (6032.1040 DE2015) EAST-INST JUMPERS (_____/_____')-EXTEND #4ACSR PRI AS NEEDED (_____')-EXTEND #4ACSR NEUT AS NEEDED (_____')-INST 1Ø OH-UG TERM (6043.1000 TSU1C1) W/ LB C/O FUSED AT 40T(3412500)-INST 2" PRI RISER (6042.1000 RIS2CSS) ON S/O BKTS APPROX. 40'(_____') UP POLE-REPULL 1/0 UG PRI APPROX. 275'(_____') FROM EXIST VAULT THROUGH RISER-INST EXIST SW#SK00537-INST 1Ø OH-UG TERM (6043.1000 TSU1L1) W/ LI C/O FUSED AT 65T(3412600)-INST 2" PRI RISER (6042.1000 RIS2CSS) ON S/O BKTS APPROX. 40'(_____') UP POLE-SPLICE AT BASE OF POLE 1/0 UG PRI APPROX. 45'(_____') THROUGH RISER-INST EXIST SW# SK00538-TRANSFER EXIST OH SEC. SPLICE AND EXTEND AS NEEDED (_____/_____')-REPLACE EXIST PUSH BRACE POLE-INST 40' PUSH BRACE (6013.5000 PUSH) SET 7' DEEP-TOP POLE TO COMMSP02 (316252-166558)-REPLACE EXIST 30' CL4 POLE-INST 40' CL1 POLE (6010.1000 PD401)-CREW TO DEEP SET 2'-6"-INST (2) RC-TRANSFER EXIST OH SEC. SPLICE AND EXTEND AS NEEDED (_____/_____')-TRANSFER EXIST OH SVC. SPLICE AND EXTEND AS NEEDED (_____/_____')-TOP POLE TO COMMSP03 (316245-166557)-RAISE UNDERBUILD 7'-INST 3Ø PRI NEUT SINGLE ARM (6033.3012 TAP313)-RAISE SECONDARY 7'-CREW TO MAINTAIN SAFETY SPACE CLEARANCESP04 (316231-166558)-REPLACE EXIST 40' CL3 POLE-INST 45' CLH2 POLE (6010.1000 PD45H2)-CREW TO DEEP SET 1'-INST 3Ø PRI NEUT SINGLE ARM (6033.3012 TAP313)-TRANSFER EXIST 25kVA 120/240v XF W/ LB C/O FUSED AT 10T(3412200)-TRANSFER EXIST OH SEC. SPLICE AND EXTEND AS NEEDED (_____/_____')-TRANSFER EXIST OH SVC. SPLICE AND EXTEND AS NEEDED (_____/_____')-TRANSFER EXIST S/L(SLAR8522)-TOP POLE TO COMMSP05 (316206-166557)-RAISE UNDERBUILD 5'-INST 3Ø PRI NEUT SINGLE ARM (6033.3012 TAP313)-INST 1Ø POLE MOUNTED TAP (6031.5100 LAT115) W/ LI C/O FUSED AT 100T(3412700) WEST-EXTEND #4ACSR PRI AS NEEDED (_____')-EXTEND # 4ACSR NEUT AS NEEDED (_____')-CREW TO MAINTAIN SAFETY SPACE CLEARANCESP06 (316208-166538) TREE TRIMMING REQ'D-REPLACE EXIST 45' CL4 POLE-INST 50' CL1 POLE (6010.1000 PD501)-INST 1Ø PTP (6031.1010 TAN115)-TRANSFER EXIST 50kVA 120/240v XF W/ LB C/O FUSED AT 15T(3412300)-REMOVE EXIST 3 SPOOL RACK-INST RC-CREW TO MAINTAIN SAFETY SPACE CLEARANCES-TRANSFER EXIST OH SEC. SPLICE AND EXTEND AS NEEDED (_____/_____')-TRANSFER EXIST OH SVCS. SPLICE AND EXTEND AS NEEDED (_____/_____')-TRANSFER EXIST S/L(SLAK4721)-TOP POLE TO COMMSP07 (316178-166556)-REPLACE EXIST 40' CL4 POLE-INST 45' CLH2 POLE (6010.1000 PD45H2)-CREW TO DEEP SET 1'-INST 3Ø PRI NEUT SINGLE ARM (6033.3012 TAP313)-REPLACE EXIST 25kVA 120/240v XF-INST 25kVA 120/240v XF (6025.1000 TRFNXF)-INST 3Ø OH-UG TERM (6043.1000 TSU3L1F) W/ LI C/O FUSED AT 100T(3412700)-INST 4" PRI RISER (6042.1000 RIS4CSS) ON S/O BKTS APPROX. 40'(_____') UP POLE-SPLICE AT BASE OF POLE 3Ø 1/0 UG PRI APPROX. 45'(_____') THROUGH RISER-INST EXIST SW# X8936-TRANSFER EXIST OH SVCS. SPLICE AND EXTEND AS NEEDED (_____/_____')-TOP POLE TO COMMSTHIS PAGE PERTAINS TO DISTRIBUTION UNDERBUILDSEE ADDITIONAL PRINT FOR TRANSMISSION NOTESSCALE: 1:100UG CIRCUIT MAP: P01DESIGNED BYUTILITIESCONTACTPHONE#COUNTY1/4 SECU-MAP NO (POWER)OP MAPEmer SectGas Wk CtrPOWER WK CTRPLAT MAPJOINT FACILITIES ARRANGEMENTSDRAWN BYCHECKED BYAPPROVED BYFOREMAN #1FOREMAN #2MAPPINGINCIDENTMAOPGas OrderElect OrderSCALEPAGEENGR - POWERENGR - GASFUNCTIONPROJECT MGRPERMITREAL ESTATE/EASEMENT21REV#3DATEDESCRIPTIONBYCONTACTPHONE NODATEOH CKT MAPCIRCUIT NOUG CKT MAPB. JOHNSON253-553-688202/07/25J. REYNA253-259-707602/07/25N/AN/AN/AB. JOHNSON253-553-688202/07/25N/ACITY OF RENTONENGR1 COMCAST TK#6585566REPLACE (5) DIST. POLES, RAISE TRANSMISSION UNDERBUILD18408 116TH AVE SE Renton, WA 98058POTELCON/AN/AN/A186069496AS NOTED1/1KINGN/AN/AQCSOKET23, R05E, S33N/AN/AA2305E131D2305E136R2305E131PAN-15N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/ARemoved at site:Grid Number:kVA Rating:Foreman to redline the following informationTRANSFORMER REMOVALCompany ID#:Primary phase connected to:Tested Secondary VoltageP07 316178-166556 25kVA 120/240vInstalled at site:Grid Number:kVA Rating:TRANSFORMER INSTALLATION (OH)Company ID#:Primary phase connected to:Tested Secondary VoltageMaterial ID#:Foreman to redline the following informationP07 316178-166556POLE TABLE (NEW)Site#Pole DataGrid #HeightClassYearRemarks / Location Ref.P01316260-1665585012'-6" DEEP SETP01316260-166558401PUSH POLE, L=18', EMBED 7'P02316252-1665584012'-6" DEEP SETP04316231-16655845H21' DEEP SETP06316208-166538501P07316178-16655645H21' DEEP SET POLE RETIREMENT TABLE TEMP TRANSFERSST. LIGHT TRANSFERSSITE#POLE DATAPOLETELTVFIBERTRANRMVDID NUMBERGRID #HEIGHTCLASSYEARTOPPEDRMVDP01316260-16655840UNKUNKN/AP01316260-16655840UNKUNKN/AP02316252-1665583042005N/AP04316231-1665584032020SLAR8522P06316208-1665384541959SLAK4721P07316178-1665564041956N/AJOB SITENew pole at site:Grid Number:kVA Rating:Foreman to redline the following informationTRANSFORMER TRANSFERCompany ID#:Primary phase connected to:Tested Secondary VoltageP04316231-16655825kVA 120/240vNew pole at site:Grid Number:kVA Rating:Foreman to redline the following informationTRANSFORMER TRANSFERCompany ID#:Primary phase connected to:Tested Secondary VoltageP06316208-16653850kVA 120/240vSCALE: 1:100UG CIRCUIT MAP: P07JOB SITE25kVA 120/240vSCALE: 1:100SITE PLAN: P01-P07PSENoNoNoYesYesYesNoYesDeveloper"Flagging Required""Outages Required""Locates Required""Veg Management Required""Joint Trench Coord Required"YesYesNoNoUNITS OF PROPERTYINSTALL ONLYCROSSARMSMATERIALQTYDIST. WOODDIST. FIBERGLASSDIST. STEELDIST. OTHERSTRANS. WOODTRANS. FIBERGLASSTRANS. STEELTRANS. OTHERSUNITS OF PROPERTYINSTALL ONLYLINE FIXTURESMATERIALQTYDIST. ARRESTERSDIST. CUTOUTSDIST. INSULATORSTRANS. ARRESTERSTRANS. INSULATORSUNITS OF PROPERTYREMOVAL ONLYMATERIALQTYDIST. ARRESTERSDIST. CUTOUTSDIST. INSULATORSTRANS. ARRESTERSTRANS. INSULATORSCROSSARMSMFP25003894RESTORATION PER CITY OF RENTON STANDARDSThis permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HR