r. 4' 6', 1 r. OR 24"
- ONE 43 BAR \HOOP FOR 6' HEIGHT
INCREMENT (SPACED EQUALLY).
'.EF NOTE 1
RECTANGULAR ADJUSTMENT SECTION
N�A�B
�fF 40jF
e
Y
43 BAR EACH CORNER r
i
\ I rr
n3 BAR EACH SIDE
03 BAR EACH WAY
PRECAST BASE SECTION
R3 BAR HOOP
n3 BARE CH
CORNER 18' MIN
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
• PUBLIC WORKS
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR PLAIN
1r
CONCRETE
ALL METAL PIPE
15'
CPSSP'.
1r
STD.SPEC. 9-05-m
SOLID WALL PVC.
STD SPEC. 9-05.12(1)
15"
PROFILE WALL PVC.
STD SPEC. 9-05.12(2)
is,
' CORRUGATED POLYETHYLENE STORM
SEWER PIPE
NOTES:
I AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHU.'.N
IN THE PRECAST BASE 9ECTKNJ, FIBERS (PLACED IN
ACCORDANCE WITH STANDARD SPECIFICATION
9-05.sot 9)I, OR WIRE MESH HAVING A MINIMUM AREA OF
0.12 SOLD (E INCHES PER FOOT SMALL BE USED WITH
THE MINIMUM REQUIRED REBAR SHOWN IN THE
ALTERNATIVE PRECAST BASE SECTION. WIRE MESH
SHALL NOT BE PLACED IN THE KNOCKOUTS AS AN
ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN
THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH
HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER
FOOT MAY BE USED
2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER
THAN 20'. KNOCKOUTS SHALL HAVE A WALL THICKNESS
OF r MINIMUM TO 2 S" MAXIMUM. PROVIDE A 1.5'
MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE
OUTSIDE OF THE PIPE AFTER THE PIPE IS INSTALLED,
FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH
STANDARD SPECIFICATION 9-04.3.
3 THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO
THE LOWEST PIPE INVERT SHALL BE 5 FEET
4 THE FRAME AND GRATE MUST BE INSTALLED WITH THE
FLANGE DOWN
S. THE PRECAST BASE SECTION MAY HAVE A ROUNDED
FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF
1FF.24V OR STEEPER-
6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE
PRECAST BASE SECTION.
7. ALL PICKUP HOLES SMALL BE GROUTED FULL AFTER THIF
INLET HAS BEEN PLACED USE GROUT TYPE 2 FOR
NON -SHRINK APPLICATIONS IN ACCORDANCE WI I"
STANDARD SPECIFICATION 0,20.3(2)
8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN
MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE
AND OUTSIDE OF ALL JOINTS, RINGS. RISERS. AND
FRAMES.
9. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS
10 FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH
11 ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE UPON COMPLETION.
UNLESS OTHERWISE NOTED, DRAWING ISNOT TO SCALE INS)
STD. PLAN - 200.00
APPR
DEPARTMENT CATCH BASIN TYPE 1 GAZ 9/28/2018 1
BATE
REMOVABLE WATERTIGHT
COUPLING OR FLANGE -
IF MAX. FOR
MAINTENANCE
SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT
NW 1/4 NE 1/4, SEC 09, T 23 N, R 05 E. W. M.
CATCH BASIN FRAME AND VANED
GRATE PER STD. PLAN 204-00
RECTANGULAR OR CIRCULAR ADJUSTMENT
SECTION ITWO SECTIONS MAX I
- MORTAR. ITYP) SEE NOTE 5
4- MIN,
26' MAX
1S" MAX
FLAT SLAB TOP
96", 120' OR 4C
EE NOTE 6 TYP
I
IMIN
1' MIN2.5'
MAFORCING
'O'GRAVEL
STEEL. (TYP. )
BACKFIL L FOR PIPE ZONE
BEDDING PER WSDOT STD.
SPECIFICATION SECTION 9-03.12(3)
G
W
SEPARATE BASE INTEGRAL BASE
PRECAST
PRECAST WITH RISER
NOTEST
vu STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LES&
2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE
SLOPED TO FACILITATE CLEANING.
3 THE RECTANGULAR FRAME AND GRATE MUST BE
INSTALLED WITH THE FLANGE DOWN THE FRAME MAY BE
CAST INTO THE ADJUSTMENT SECTION
4 KNOCKOUTS SHALL HAVE A WALL THICKNESS OF r
MINIMUM TO 2.Y MAXIMUM. PROVIDE A 1 5' MINIMUM) GAP
BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE
PIPE AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH
JOINT MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3.
5. ALL GRADE RINGS, RISERS. AND CASTINGS SHALL BE SET
IN MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04 3
6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE
CONNECTOR (KOR•N•SEAL BOOT WITH CORRUGATED PIPE
ADAPTER OR APPROVED E(XUAL) WHEN CONNECTING TO
AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF
THE SAME MATERIAL AS THE CONNECTING PIPE.
7 MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURERS DIRECTIONS,
8 FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH
9, ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE UPON COMPLETION
CATCH BASIN DIMENSIONS
CATCH BASIN
DIAMETER
MIN. WALL
TMICKNE99
MIN BASE
THICKNESS
MA%IMUM
KNOCKOUT SIZE
MINIMUM
DISTANCE
BETWEEN
KNOCKOUTS
4W
54'
4.5'
✓E
4r
S'
60'
5'
B'
48'
8'
72'
6'
8'
60"
12'
1.
r
12"
7r
12'
96,
r
12'
84'
12'
12T
10"
12'
98"
t2'
141"
12"
12'
108,
12'
PIPE ALLOWANCES
CATCH BASIN
PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER
DIAMETER
CONCRETE
ALL METAL
CPSSP'
SOLID WALL
PVC °
PROFILE WALL
PVC
48"
24'
3T
24'
30"
30'
54"
30,
36"
30'
36"
36"
613"
36'
42'
36'
42"
42"
72"
dr
54"
42'
48"
48'
84"
5A'
1'
1.
48"
1"
98"
60'
72"
50'
48"
48'
120'
66'
84"
60,
48"
48-
144'
78'
9fl"1
60-
48"
48'
CORRUGATED POLYETHYLENE STORM SEWER PIPE ISM. SPEC. 9-05.20)
STD. SPEC. 9-05, 12(11
SPEC 9-05 1242)
STD. PLAN - 201.00
PUBLIC WORKS CATCH BASIN TYPE 2 R
DEPARTMENT FOV""' -
GAZ 9/28/2018 1
BATE
,4', r. 12'. OR 24'
ONE 43 BAR HOOP FOR 6' HEIGHT
INCREMENT (SPACED EQUALLY),
SEE NOTE 1
RECTANGULAR ADJUSTMENT SECTION
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR PLAIN
CONCRETE
12"
ALL METAL PIPE
15'
CPSSP',
STD. SPEC. 9-0620
12'
SOLID WALL PVC.
STD. SPEC. 9,05.1211)
15,
PROFILE WALL PVC,
STD. SPEC. 9-05.1212)
15'
'CORRUGATED POLYETHYLENE STORM
SEWER PIPE
.�.,tES SFF4b'
E� Tes
NOTES:
\
\
1
AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN
t71
THE PRECAST BASE SECTION, FIBERS (PLACED IN
U�
ACCORDANCE WITH STANDARD SPECIFICATION 9.0S WET)).
�STS
Oct
OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE
INCHES PER FOOT SHALL BE USED WITH THE MINIMUM
REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST
BASE SECTION WIRE MESH SHALL NOT BE PLACED IN THE
n3 BAR EACH CORNER I
KNOCKOUTS- AS AN ACCEPTABLE ALTERNATIVE TO THE
REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT
SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12
03 BAR EACH SIDE
SQUARE INCHES PER FOOT MAY BE USED
TOP AND BOTTOM
2.
THE KNOCKOUT DIAMETER SMALL NOT BE GREATER THAN
ONE R3 BAR
18'. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2"
ACROSS BOTTOM
MINIMUM TO 2.5' MAXIMUM PROVIDE A 1.5" MINIMUM GAP
BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE
PRECAST BASE SECTION
PIPE AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH
JOINT MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9-04.3.
3,
THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE
LOWEST PIPE INVERT SHALL BE S
4
THE FRAME AND GRATE SHALL BE INSTALLED WITH THE
FLANGE DOWN.
5.
THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR,
AND THE WALLS MAY BE SLOPED AT A RATE OF 1 H 24V OR
\
STEEPER8.
THE STRUCTURE OPENING DIMENSIONS SHALL BE
XT
MEASURED AT THE TOP OF THE PRECAST BASE SECTION
A3 BAR EACH
7.
ALL PICKUPHOLES SHALL BE GROUTED FURL AFTER THE
CHAS
CORNER 18"IMIN
INLET BEEN PLACED. USE GROUT TYPE 2 FOR
I
WITH
03 BAR HOOP
SNStiRIN TANDARD SPt�CCATI ION �IN�ZORDANCE
8.
ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR
IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3
THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL
JOINTS, RINGS RISERS, AND FRAMES
SEE NOTE 1
9.
MORTAR SHALL BE MIXED AND APPLIED PER
ALTERNATIVE PRECAST BASE SECTION
MANUFACTURER'S DIRECTIONS
10
FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
Tt
ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAi'.
VISIBLE UPON COMPLETION,
UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS)
Aowu
STD. PLAN - 200.30
PUBLIC WORKS
ED
DEPARTMENT
CONCRETE
INLET
GAZ 9/28/2018 1
BATE
RECESSED Not ;o Scale
LIFT POCKET
o o FRAME
3/4" LETTERING `SEWER` -0 1 DIAMETER , 1'-0'
400 o � o � o
SEWER (2) BOLT SOC. (ALLEN HEAD)
5/8" - 11 X 15 STAINLESS
o a o STEEL
REF PART #00981177
�10-112'
Tt-3/16" 1SEE NOTE 3
5/8"
1�
1"
1 ,,B
2-1/4
III- 12-3/4�
11"
12-
AST IRON RING AND COVER
BOLT DETAIL
45' (T/6) BEND
SAND OR
EXPANDABLE
FOAM
4
Pa
J~
lXO
P PIPE MATERIAL AS SPECIFIED
BY THE ENGINEER
45- (1/8) BEND
1 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC
No 3698 (PRODUCT NO D0369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY
2 IN UNIMPROVED AREAS, POUR A 8" THICK; Y-O' SOUARE
CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER
3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106
STD. PLAN - 403.1
PUBLIC WORK5 8" OR 6" CLEANOUT
DEPARTMENT FOR SANITARY SEWER MAIN Martin PBStUCIW26/2020
BD DATE
1
200.00
2
20 1 ,00
3
200.30
4
403, 1
C3.0
SCALE: NTS
C3.0
SCALE:NTS
C3.0
SCALE: NITS
SCALE. NTS
7 MIN CLEARANCE TO
ANY PORTION OF FLOW RESTRICTOR
TEE INCLUDING ELBOWS
r MIN.
ELBOW RESTRICTOR,
SEE DETAIL AND NOTE 10 -
8' MIN
J r MIN.
8' MAX.
PLATE WELDED TO ELBOW WITH
ORIFICE AS SPECIFIED. SEE NOTE 3
ELBOW RESTRICTOR DETAIL
ELEVATION PER PLANS
12' MIN. UNDER
PAVEMENT
ADDITIONAL LADDER RUNGS (IN SETS) TO
ALLOW ACCESS TO TANKS OR VAULTS
WHEN CATCH IS FILLED WATER
i
T
I 1
I J
i
/
ANGLE AS
/
NECESSARY,
/
SEE NOTE 7
PLAN VIEW
FRAME 6 SOLID COVER MARKED •DRAIN" WITH
LOCKING BOLTS PER STD. PLANS 2D4-40 AND 204,50
16" MINX.
VERTICAL BAR GRATE FOR
SECONDARY INLET
6'MIN.
DESIGN WATER
ELBOW RESTRICTOR.
ERFAff
SEE DETAIL AND NOTE 10
HANDHOLDS. STEPS. OR LADDE+t
PIPE SUPPORTS, SEE NOTE 6
tr (TYP.)
1.5xD
f
SEE NOTE 9(TYP.)
MIN.
2. MN
T- I
ISOMETRIC I
OUTLET PIPE, SEE
INLET PIPE
NOTES 1 A 5
7
MIN.
SHEAR GATE WITH CONTROL ROD FOR
INVERT AND
CLEANDUTfDRA1N (ROD BENT AS REQUIRED
ELEVATION PER PLANS
FOR VERTICAL ALIGNMENT WITH COVER)
12' SECTION OF PIPE ATTACHED BY
PER STD. PLAN 237.30
GASKETED BAND TO ALLOW REMOVAL
7
12* MIN,
WELDED RESTRICTOR PLATE WITH
ORIFICE DIA AS SPECIFIED. SEE NOTE t0
SECTION A
NOTES:
USE A MIMIMUM OF A 54' DIAMETER TYPE 2 CATCH BASIN
2 OUTLET CAPACITY 100-YEAR DEVELOPED PEAK FLOW
3 METAL PARTS PREFERRED TO BE STAINLESS STEEL ALUMINIZED STEEL. OR ALUMINUM ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMEN's • na
4 FRAME AND LADDER OR STEPS OFFSET SO.
A CLEANOUT GATE IS VISIBLE FROM TOP
8 CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE-
C. FRAME IS CLEAR OF CURB
5. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE OUTLET PIPE TO HAVE SMOOTH O D. EQUAL TO CONCRETE PIPE I D- LESS 114",
6 PROVIDE AT LEAST ONE 3' X 090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL (MAXIMUM T-O' VERTICAL SPACING)
7 LOCATE ELBOW RESTRICTOR(S) AS NECESSARY 70 PROVIDE MINIMUM CLEARANCE AS SHOWN
8. LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER.
9. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR IKOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING.
TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE.
70 IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED.
UNLESS OTHERWISE NOTED. DRAWING IS NOT T05GLE (NISI
STD. PLAN - 237.00
• PUBLIC WORKS FLOW CONTROL STRUCTURE - y
V DEPARTMENT RESTRICTOR TEE Martin Pastucha 8/13/20
90. DA7E
5 23 7.00
C3.0 SCALE,NTS
DocuSign
Envelope ID: 3SIB34D3-7EOA476C-ADB34329PFEOC108
SURFACE WATER STANDARD PLAN NOTES:
I 1 I ' lT 4A. ' - AI NL- I - - %TH I"I IV I' .. F, I 'v -1:
HE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INL.0 . URA; LJ IN 'rl' U 2 J! _ L I'.A .,� I AL. L NU U c L ,. !� C t � C L
+'ROJECT THE APPLICANT OR OWNER. HEREBY REFERRED TO AS APPLICANT MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER. THL
APPLICANT SHALL NOT RENUMBER NOR EDITTHE REMNNING NOTES. IF ADDITIONAL ARE NEEDED FOR SPECIFIC ASPECTS. THEY SHALL BE ADDED AFTER THE
'.;URFACE WATER STANDARD PLAN NOTES
BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS. A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY
REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANTS CONTRACTOR
THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION
-I ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE
WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC). AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL
CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO
CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO
THE CITY
4 APPROVAL OF THE ROAD. GRADING, PARKING, BUILDING. AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER.
SEWER. GAS, ELECTRICAL ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES. VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY
THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, ANY DEVIATION
FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY.
_ A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS -
THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABUSHED BY FIELD SURVEYOR OBTAINED FROM AVAILABLE RECORDS AND SHALL
THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANTS
CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN. AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT
SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS-BULT DRAWINGS ALL
UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A
CONFLICT EXISTS.
VERTICAL DATUM SHALL BE NAV0 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH). UNLESS OTHERWISE APPROVED BY THE CITY.
REFERENCE BENCHMARK. DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS.
R ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SMALL BE COMPACTED TO 95%MAXIMUM DRY DENSITY PER SECTION 2-03.3000 - COMPACTION AND
MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERM1tEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH BACKF IU •_ sllnu
SE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY
- OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRANAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON T"E -=
APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS
1;1 ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION WHERE SHOWN ON THE PLANS OR WHERE
DIRECTED BY THE CITY. THE EXISTING MANHOLES. CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED
1 I ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE
APPROVED BY THE CRY.
12 ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD
SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION
MATERIAL. AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE
SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220 00,220 10, AND
22020
13 STEEL PIPE SHALL BE ALUMINIZED. OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 51NSIDE AND OUTSIDE.
14 ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN
204.10. 20420. 2D4.30, 20440. AND 204 50. STRUCTURES SHALL HAVE.
• RECTANGULAR OR ROUND. SOLID LIDS WHEN NOT COLLECTING RUNOFF. AND OUTSIDE OF THE ROADWAY.
• ROUND. SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY. BUT OUTSIDE OF THE CURB/GUTTER LINE
• ROUND. SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CRY. PRIVATE STRUCTURE LIDS OUTSIDE
PUSUC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO -
IF, BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4 1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDAI
I-, LIDS OF MANHOLES/CATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING ALL MANHOLE/CATCH BASIN RIMS
SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN
17 ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 31 SLOPE FROM THE EDGE OF THE
DRIVEWAY TO THE BOTTOM OF THE DITCH
6 26 7.00
C3.0 SCALE,' NTS
UNLESS OTHERWISE NOTED DRAWING 6 NOT TO SCALL : `.
STD. PLAN - 267.00
PUBLIC WORKS
SURFACE WATER STANDARD PLAN
flwoil4 Dy.
DEPARTMENT
NOTES (1 OF 2)
artin Pastucha8/13/zozo
1 a:a
DATE
05/23/23
DocuSign
Envelope ID: 3B1B34D3-7EOA476C-AD834329FFEOC108
SURFACE WATER STANDARD PLAN NOTES:
THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PUN SET. ALL THE NOTES ON THE LIST MA) N� 7 1 L F i A'I: I (, C'L LI'
•'ROJECT THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER. THE
APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAIN64G NOTES- IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE
:SURFACE WATER STANDARD PLAN NOTES
18 ROCK FOR EROSION PROTECTION OF ROADSIDE OITCHES. WHERE REOUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT
AND SHALL MEET THE FOLLOWING SPECIFICATIONS
• 4-8INCH ROCK 140 - 70% PASSING;
• 2 - 4 INCH ROCK 130 - 40% PASSING; AND
• LESS THAN 2INCH ROCK 110. 20%PASSING.
I D. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE
CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE. UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BAPS
20, THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED, A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED'STORM' OR'DRAIN' SHALL BE LOCATED AT THE
PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00
21, ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDEL
TO THE CITY PRIOR TO CONSTRUCTION
22 ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV
ACCORDING TO THE CITY STANDARD PLAN 266.DD CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL
PROJECT CURBS, GUTTERS ANO.IOR PAVEMENT
23 ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.30) OF THE WSDOT STANDARD SPECIFICATION:-
AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS
TESTED
24 FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED. ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOLI.
EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLA":
28400
25 ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION ANMOR LIABILIT ,
CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM
SYSTEM PROVIDED DURING CONSTRUCTION
26 ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT- FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY Of
THE PUBLIC. AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED
RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY ALL SECTIONS OF THE WSDOT
STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY
27. PROJECTS LOCATED WITHIN THE CITSHALL COMPLY AQUIFER PROTECTION AREA (APA) SHACOMPLY WITH SPECIAL REOUIREMLM 160E THE RENTON SWOM AND AQUIFER
PROTECTION REGULATIONS (RUC 4-3-050)
28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASINiMANHOLE LIDS, CLEANDUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH. INTERSECTIONS U,
STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A
SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NONSKID LID PER ADA REQUIREMENTS
29. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT.
30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1 A2 OF THE RENTON SWOM
31. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE
PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO
CONSTRUCTION APPROVAL OF THE PAVEMENT COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO TH-
PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE. THEN THE PAVEMENT IS CONSIDERED TO MEET THE
MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1.D00 SQUARE FEET OF PERMEABLE PAVEMENT, IF THIS TEST IS NOT CONCLUSIVE.
THEN ANOTHER TEST PER ASTM C1701 SMALL BE CONDUCTED, FOR LARGE AREAS IF G., PARKING AREAS). TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE
WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING
ASTM C1781.
7 267. 1 0
C3.0 SCALE.' NTS
UNLESS OTHERWISE NOTED, DRAWING 6 NOT TO SCALL '.
STD. PLAN - 267.10
PUBLIC WORKS
SURFACE WATER STANDARD PLAN
+br»4w:
DEPARTMENT
NOTES (2 OF 2)
artin Pastuchg/13/zozo
8:48
•"•^fS•AFl7B46490 OAT[
FLOW
6" MiN PIPE -
INFILTRATION FILTER
SECTION
NTS
LAST REVISED: 01/2017
12" MiN PIPE
6" MIN PIPE
FLOW
WiRE MESH BASKET
1. PRODUCT SHALL BE ORENCO S06`1236-6L STORMWA TER CATCH BASIN OR
EQUIVALENT.
2. PLACE THE INFIL TRA TION FIL TER UPSTREAM OF THE INFIL TRA TION SYSTEM (EX.
DRYWELL, INFILTRATION TRENCH, ETC.).
8 INFILTRATION F/LTEl4
c3o SCALE. NTS R-423406
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SURFACE WATER UTILITY
J Farah 08/11 /2023
DEVELOPMENT ENGINEERING
NJanders 08/04/2023 '
SURVEYED:
_
SCALE:
NTS
VERTICAL: NAVD 1988SHUM
HORIZONTAL: NAD1983/183/1991
-
® CITY OF
SHORT PLAT
CIVIL CONSTRUCTION PERMIT
DATE:
05/23/23
DESIGNED:
SC
FIELDBOOK:---
RENTON
PAGE: ---
DRAWN:
cc
ONE INCH
DATU M
GRADING & DRAINAGE DETAILS
DRAWING N0:
CHECKED:
SC
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
Planning/Building/Public Works Dept.
1157 QUEEN AVE NE, RENTON, WA. 98056
C3. 1
NO.
REVISION
BY
DATE
APPR
APPROVED: