HomeMy WebLinkAboutR-423410M
1
1
W
C�
G
IZ
W
n
Z
_0
U
IZ
�I—
U7
Z
0
U
J
U
1
n
I—
LL
0
VJ
2
U7
O
co
J
J
J
J
DEPARTMENT OF COMMUNITY CITY OF
AND ECONOMIC DEVELOPMENT Renton 0
PARCEL'A'/ TRACT 'A'
TREE RETENTION WORKSHEET
Planning Division
1055 South Grady Way -Renton, WA 98057
Phone 425-430-7200 1 www rentonwa.gov
1. Total number of trees over 6" diameter', or alder or cottonwood
trees at least 8" in diameter on project site 3 trees
2. Deductions: Certain trees are excluded from the retention calculation:
Trees that are dangerous`' trees
Trees in proposed public streets trees
Trees in proposed private access easements/tracts trees
Trees in critical areas and buffers trees
Total number of excluded trees: 1 trees
3. Subtract line 2 from line 1: 2 trees
4. Next, to determine the number of trees that must be retained °, multiply line 3 by:
0.3 in zones RC, R-1, R-4, R-6 or R-8
0.2 in all other residential zones
0.1 in all commercial and industrial zones 1 trees
5. List the number of 6" in diameter, or alder or cottonwood trees
over 8" in diameter that you are proposings to retain'': � trees
6. Subtract line 5 from line 4 for trees to be replaced:
(if line 6 is zero or less, stop here. No replacement trees are required) 0 trees
7. Multiply line 6 by 12" for number of required replacement inches: o inches
8. Proposed size of trees to meet additional planting requirement:
I'Minimum 2" caliper trees reauired for replacement, otherwise enter Ol inches per tree
9. Divide line 7 by line 8 for number of replacement trees6:
(If remainder is .5 or greater, round up to the next whole number) 0 trees
' Measured at 4.S' above grade.
A tree certified, In a written report, as dead, terminally diseased, damaged, or otherwise dangerous to persons or property by a licensed
landscape architect, or certified arborlst, and approved by the City.
Critical areas, such as wetlands, streams, floodplains and protected slopes, are defined in RMC 4-3-050.
` Count only those trees to be retained outside of critical areas and buffers,
s The City may require modification of the tree retention plan to ensure retention of the maximum number of trees per RMC 4-4-1301-117a.
° When the required number of protected trees cannot be retained, replacement trees, with at least a two-inch (2') caliper or an evergreen at least
six feet (6') tall, shall be planted- See RMC 4-4-130.H.1.e.(ii) for prohibited types of replacement trees.
t
H:\CED\Data\Forms•Templates\SeIf. Help Handouts\Planning\Tree Retention Worksheet.docx 08/2CI5
PLANT SCHEDULE
Qty. Symbol Botanical/ Common Name Size/ Remarks Location
TREES:
EXISTING TREE TO REMAIN
]STING TREE TO BE REMOVED
.er g. 'Flame'/ AMUR MAPLE
uja plicata 'Hogan'/ HOGAN W R CEDAR
agnolia grandiflora Little Gem'/
EVERGREEN MAGNOLIA
4 Parrotia p. 'Vanessa'/ PERSIAN PARROTIA
min. 2" cal., single trunk Lots A and B
min. 8'0" hgt. (4" cal.) Lots A and B
min. 2" cal. Lots A and B
min. 2" cal., single trunk Offsite
TREE RETENTION/ REPLACEMENT PLAN NOTES:
See Tree Assessment 1157 Queen Ave NE Renton, WA (Tree Report)
prepared by Arbor Info LLC, 2406 N Castle Way Brier, WA for Tree
Descriptions, Driplines, Assessment, Construction Impacts and other
Site Tree information.
PARCEL 'A': Replacement Inches Required- 0
TREE DENSITY NOTES:
2 Trees per 5,000 s.f. Required
PARCEL 'A' + TRACT 'A': 14,560 s.f. (/) 5,000 (x) 2 = 6 Trees Required
12 Trees Provided (11- new + 1- Existing Maple)
Glenn Takagi
1V Z Landscape Architect
a00 6 ~ Z 18550 Firlands Way N.
m Z Suite #102
gLII) 3 a Shoreline, WA 98133
Q " (206)542-6100
glencol 029@earthlink.net
SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT
NW1/4.NE 1/4, SEC 09,T23 N.ROS E. W. M.
0 T-13
Rej
-C
0.1"DFIR I
y
T-A
\
I G
O \
\.-
21.9"DFIR
- — —\ - - - - - - - - - - - -i
\ yl
T_-10
_K15.8"DFIR
\ Tree Protection — — —
\ \
/
a
Fencing -- — —— �— — — — — — — — —
10
\ /
I /
T-9
30.6 DFIR
a ° d
+ /
LOT B
II
Tree 'Dripline' I C
�/
I
d
T-1 T—
'(typ•) 51.;"MAD I 12. "sM0
(
-- — /
ExistingTree to Existing Tree to be
r
Remain (typ.) t \ Removed (typ.) I
R
26. I \
26.3"DFIR
d
\ d`
\ L/
30.5"DFIR a / — —
°.° Existing Tree to be
a
T-a2 ° Removed (typ.) —
f-- --T--
° 3"DFIR14
° ° d
d d \d
T-6
3a
1.8"DFIR
LOT W
.fi
Tree, Dripline
(typ.)
T-5
/ 3E25.3"DFIR
Q
*29.5"Dlr/
I d
REVISION
R
I
\ I I
I \ I I
\ Tree 'Dripline'
(typ.) "
/ Tree Protection /
Fencing
I
Existing Tree to
Remain (typ.) /
SURVEYED
DESIGNED
GT
DRAW
GT
CHECKED;
GT
BY DATE APPR AFC:
APPROVED
0' 5' 10, 20'
SCALE: 1" = 10'- 0"
FIORIZONT�AL tI D 198 IO/1/1991
1 "= 10'-0"
ONE INCH DATU M
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
NORTH
CITY OF
RENTON
Planning/Building/Public Works Dept.
!'TRACT
A
�n v
R-42341 0
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING o
AWeihs 08/08/2023
SHUM SHORT PLAT 3/ 16/23
CIVIL CONSTRUCTION PERMIT �0ft
PAGi
TREE RETENTION/ REPLACEMENT PLAN DDPAW MW.
L3.0
1157 QUEEN AVE NE RENTON, WA 98056 giEET 12 OF 12
X
X
X
X
X
X
X
,
U
T
0
O
N
N
Q
J
L0
O
O
N
�N•
LL
I-
J
�I
0
U'7
U'7