Loading...
HomeMy WebLinkAboutzR-4234set/,. N p W "" 40 �, HORIZONTAL SCALE Iv STA 2+58.51, 33.0' RT END 5' WIDE SIDEWALK P SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT NW 1/4 7 NE 1/4, SEC 09, T 23 N, R 05 E. W. M. STA 20+37.15, 6.1' RT END ROAD WAY TRANSITION/TAPER. I (n i � •- 1 PROJECT STATIONING. • l FENCE 5' - V S 20+ OP,L STA TION 2+00 /S PERPENDICULAR ' a rr TO THE NORTH PROPERTY LINE. TREE CANOPY �\ \ oA o� o LLI +� N87'59'50"W 111.12' _%-STA 20+00.00, 13.0'LT - - - - =4 END CURB GUTTER & STA 2+00.00, 13.O' RT FO ND 'REBAR I D O ��� 20 00- I ' AP AT GRAD �•1 <' _SIDEWALK. BEGIN ROADWAY z END EXTRUDED M 09 o2-z X � \ FOUND 1/2- RP R TRANSITION/TAPER. - - O CONCRETE CURB � 1 12 / � I o F r I I S•�i COMPLETE GRIND AND OVERLAY, ABANDON EXISTING P N L OT B I, \ ALONG PROJECT FRONTAGE, TYP SIDE SEWER 1o C) 6 0' 5753 SF _ �, I (PER CITY OF RENTON STANDARDS) 1 8.0' PLANTER on z I 1 1 --------- ,'-1.5' CURB & GUTTER �V 1 j I I j O I I + P] 13.0' DRIVE LANE � II II y \ 267E I I I v I,, PA VEMENT PATCH (VARIES) I I I i ❑5 - ,- I cn ------- 5. 0' SIDEWALK > STA 1+39.60, 13.0 RT U BEGIN EXTRUDED _ _x TRACT A 4 a r I ! JJ i CONCRETE CURB I 3291 SF QJ $T,nA ,T-L-7.7 6;RT[7]Ub-.. 1I101I 1I 01 212' WDE DRI VEWA Y17 I lii :l•.'��j i�� ss- Jo r SS 0 I + I I I I I I I I i 1'• i STA 1+15.60, 13.O' RT O END EXTRUDED SSMH I I I = CONCRETE CURBT 8- GONG NCES STA 1+5.60, 9QL � 2 ln' E)rTRIDFQ L OT A ✓i i � I i 10i 19 CONCRETE CURB I F I 5515 SF 3 I I I I a TRANSITION I I N 6" 2 4 I-IpUpII ■ I j _ X L J to _ - / SL STA 0+76.35! 10.9' RT -I J FENCE CROSSES PIL r' •. � l IVI - 10' EXTRUDED CONCRETE �� 0 I CURB RETURN ° �* O _ / 5' L LF SSMH 0 TOP 432.03 -0 ° E a. P N87°59'46"W 114.151 BOTTOM STRUC E STA 18+68.89 13.0' LT ° I 9 R I CEDAR HEDGE ELEV 42766 U 0. 02 21 r NO CHANNEL BEGIN CURB, GUTTER °" "BASIN SIDEWALK NSITION 433 33 W & SIDEWALK. END ROADWAY "CONCIE432.3 IN-W) \ ' ' GMP IE 43, za t T_S, P.L. 0 STA 0+68.11 v I TRANSITION/TAPER. ��6, o 6"CONCIE43236(DU,.E) STA 0+67.90, 29.5' RT 6 L. ® STA 18+68.89 0I EGIN ALK ❑ 12 9 1 EXISTING CURB LINE STA 0+56.60, 27.4 RT (APPROXIMA TED FROM �, o EGIN EXTRUDED AERIAL PHOTO, NOT 0i ONCRETE CURB SURVEYED), TYP -- STA 18+29.38, 8. 1' RT BEGIN ROADWA Y N I TRANSITION/TAPER. o I ° n SITE PLAN o 7°59'46"W 114 -* Eo E 2 DEDICATION PLAN SCALE- 1 "=30' PROJECT TEAM; OWNER: HOl-FLING SHUM 17723 110TH PL. SE RENTON, WA 98055 PH.- EMAIL: SHARON. ZHANG29@YAHOO. COY PROJECT COORDINA TOR. - DWI DESIGN DA WD WI 14632 14 TH AVE SE MILL CREEK, WA 98012 PH.- (425)512-1780 EMAIL: DWUDESIGNOGUAIL. COM PROJECT ENGINEER.• PA TRICK HARRON & ASSOCIA TES, LLC SCHWIN CHAOSILAPAKUL, PE 14900 INTERURBAN AVENUES, STE 1279 SEA TTLE, WA 98168 PH.- (206)674-4659 EMAIL: SCHWWOPA TRICKHARRON. COY PROJECT SURVEYOR.• DA WD EVANS AND ASSOC. INC. VANCE V. BLUE 20300 WOODINVILLE SNOHOMISH RD NE WOODINVILLE, WA 98072 PH.- (425)415-2023 EMAIL: VANCE. BL UEODEAINC. COM PROJECT GE07ECHNICAL: GARY A. FLOWERS, PLLC GEOLOGICAL & GE07ECHNICAL CONSULTING 5205 23RD A VE W EVERETT, WA 98203 PH.- (206)819-4304 EMAIL: GFLOWERS01000UCAST.NET PROJECT ARBORIST.• ARBOR INFO LLC TOM HANSON 2406 N CASTLE WAY BRIER, WA 98036 PH.- (206)300-9711 EMAIL: TOM. HANSONOARBORINFO. COY PROJECT LANDSCAPE ARCHITECT• GLENN TAKAGI 18550 FIRLANDS WAY N SHORELINE, WA 98133 PH.- (206)542-6100 EMAIL: GLENCO10290EAR THLINK. NET PROJECT INFORMATION; DEVELOPMENT DA TA: PROJECT NAME SHUM PRELIMINARY SHORT PLA T PROPERTY ADDRESS 1157 QUEEN AVE NE RENTON, WA 98056 PARCEL NUMBER 1065700100 ZONED R-8 PROPERTY AREA 17,174 SF (0.39 AC) RIGHT-OF-WAY DEDICA TION 2,615 SF (0.06 AC) PROPERTY AREA (POST DEDICATION) 14,560 SF (0.33 AC) BUILDING SETBACKS. - FRONT YARD 20 FT SIDE YARD 5 FT REAR YARD 20 FT MINIMUM LOT SIZE 5, 000 SF LOT COVERAGE (BLDG) 507. (MAX) DENSITY CAL CULA TION.- 14,559SF LOT / 43,560 = 0.334 * 8 (LOTS ALLOWED PER ACRE) = 2.67 = 2 LOT SHORT PLAT PROPOSED. !9f1/11111461 WA TER.- CITY OF RENTON SEWER: CITY OF RENTON FIRE.- RENTON REGIONAL FIRE AUTHORITY LEGAL DESCRIPTION; PARCEL A OF KING COUNTY BOUNDARY LINE ADJUSTMENT, RECORDED UNDER RECORDING NO. 9802099012, RECORDS OF KING COUNTY, WASHINGTON. DATUM; SCALE- 1 "=20' VERTICAL DATUM.- NA VD88 ® SITE CALLOUTS; SITE NOTES; SITE BENCHMARKS-- 1. PROPERTY BOUNDARY, TYP. 1. ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY SHALL COMPLY WITH THE TRENCH TBMI: TOP OF REBAR AND CAP, SET IN ASPH DRIVE, 46' (f) SW OF SW CORNER OF 2. FUTURE BUILDING FOOTPRINT AND DRI VEWA Y, TYP (FOR REFERENCE ONL Y). RESTORA TION AND STREET 0VERLA Y REQUIREMENTS. SUBJECT PROPERTY ON SITE AS SHOWN. ELEVA TION = 434.36'. J. EXISTING TREES TO BE PROTECTED -IN -PLACE UNLESS OTHERWISE NOTED, T1P (SEE 2 A SEPARATE FRANCHISE PERMIT IS REQUIRED FOR POWER AND TELECOM PROVIDERS SHEET CSP2.0 AND L3 FOR LIMITS OF DISTURBANCE AND TREE PROTECTION). TO RELOCATE FACILITIES. FRANCHISE PERMIT MAY BE OBTAINED POST CIVIL T9M2.- TOP OF REBAR AND CAP, SET IN MIDDLE OF SUBJECT PROPERTY AS SHOWN. 4. INSTALL CEMENT CONCRETE TRAFFIC CURB & GUTTER, PER CITY OF RENTON STD. PERMIT ISSUANCE. ELEVA770 = 430.64'. PLAN NO. 101, 101.1 AND 103, TYP (SEE DETAILS 1, 2 AND 4, SHEET C1.1). 5. INSTALL EXTRUDED CONCRETE CURB, PER CITY OF RENTON STD. PLAN NO. 101, TYP ® STORM CA L L O UTS; EARTHWORK Q DA NT/T/ ES; (SEE DETAIL 1, SHEET C1.1). 6. INSTALL 5' CONCRETE SIDEWALK, PER CITY OF RENTON STD. PLAN NO. 102 (SEE 1. PROPOSED STORM DRAINAGE SYSTEM, TYP (SEE SHEET C3.0 FOR DRAINAGE PLAN). CUT 260 CY DETAIL 3, SHEET C1.1). 5. 0' (MIN) FROM LOT PROPERTY LINE. FILL 730 CY 7. INSTALL 12. 0' WIDE CONCRETE DRIVEWAY, PER CITY OF RENTON STD. PLAN NO. TOTAL VOLUME- 990 CY 104.3 (SEE DETAIL 5, SHEET C1.1). ®_UTI L I TY CA L L OUTS; NET VOLUME (FILL): 470 CY 8. INSTALL ASPHALT ROADWAY, PER CITY OF RENTON STD. PLAN NO. 110 AND 110.1,THESE TYP (SEE DETAIL 6 AND 7, SHEET C1.1). 1. PROPOSED DOMESTIC WA TER SYSTEM, TYP (SEE SHEET C4. 0 FOR WA TER PLAN). QUANTITIES ARE FOR THE ESTABLISHMENT OF A CLEARING AND GRADING PERMIT 9. INSTALL 25 LF CHANNELIZATION MARKING PER WSDOT STD. PLAN NO. M-20.10-04. 2. PROPOSED SANITARY SEWER SYSTEM, TYP (SEE SHEET C4.0 FOR SEWER PLAN). ONLY AND SHALL NOT BE CONSIDERED TO INDICA TE A BALANCED SITE OR ACTUAL CUT AND FILL QUANTITIES REQUIRED BY THE CONTRACTOR. THE ABOVE GRADING VOLUMES 10. INSTALL STREET TREE, TYP (SEE PLANTING DETAIL, SHEET L2). J. EXISTING FIRE HYDRANT - FUTURE STRUCTURES WILL BE WITHIN 300' (MAX. ARE FROM NEAT -LINE EXISTING GRADE TO FINISHED GRADE CALCULATIONS AND MAKE 11. INSTALL 5' WIDE ASPHALT SIDEWALK TRANSITION TO EXISTING GRADE, TYP. DISTANCE APPROX. 280' TO FUTURE LOT B STRUCTURE). NO ALLOWANCE FOR STRIPPING$, GRAVEL, PAVEMENT SECTION MATERIALS, UTILITY 12. INSTALL NEW UNDERGROUND POWER ALONG PROPERTY FRONTAGE (IN PLANTER 4. PROPOSED FIRE HYDRANT ASSEMBLY (SEE SHEET C4.0). COORDINATE WITH EXCAVATIONS, AND VOLUMES LOST AND GAINED THROUGH EXPANSION AND COMPACTION AREA), AS SHOWN. REMOVE AND RELOCATE EXISTING POLE AT NORTH END OF PROJECT ARBORIST FOR TREE PROTECTION ON HYDRANT INSTALLATION. OF CUT AND FILL MATERIALS. PROJECT AREA, TO MAINTAIN EXISTING OVERHEAD POWER. UNDERGROUND NEW SERVICE SOUTH OF THE PROJECT AREA (TO NEXT POLE SOUTH). PROVIDE GUY DEDICATIONS III EASEMENTS; THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THEIR OWN QUANTITIES FOR WIRES FOR POLE SUPPORT. ALL ELECTRICAL WORK, BY OTHERSS, SEE SITE NOTE 2. # BIDDING PURPOSES AND SHALL NOT HOLD THE ENGINEER OR OWNER RESPONSIBLE FOR 13. PROPOSED ON -SITE TREE, TYP (SEE LANDSCAPE PLANS). 1. 23.0' - PIERCE AVE NE RIGHT-OF-WAY. ANY ERRORS IN THEIR BID QUANTITIES RESULTING FROM THE ABOVE APPROXIMATE 2. 3.0' - PIERCE AVE NE RIGHT-OF-WAY. EARTHWORK QUANTITIES. G DS// J. PRI VA TE ACCESS AND UTILITY EASEMENT LOT A IN BENEFIT OF LOT B. �A pF WASy'�•,Cj.•:9 02 • �r • SURVEYED: SCALE: 1 "=20' VERTICAL: NAVD 1988 HORIZONTAL:NAD1983/183/1991 CITY OF DESIGNED:U Sc 3 • � RENTON DRAWN: lIx, ..Is CC ••.• ONE INCH DATUM N E CHECKED: SIC AT FULL SCALE Planning/Building/Public Works Dept. 05/23/23 NO. REVISION BY DATE APPR IF NOT ONE INCH SCALE ACCORDINGLY APPROVED: Sc ; . � Maestro m N NE lAln S NE 1Nh S Q I O NE 131h PI e InAuto Parts - lor< o . g _ m m E,mS Q NE-h 51 0 NE 121h St Q NE 12th Se Q; o 3 Valgree�ne R Q - 11 Re Queen Ave NE a on, WA 98056 NE 1111, PI ® PROJECT SITE NE ltthm QThe Highlander - 3 Evangelical Chinese NE tom Pl m NE 10mN St And raw Church of SKC Presbyterian Church 0 Bethlehem Luiheran Church Q Q NE 1- Renton Seventh -day Adventist Church 3 VICINITY MAP SCALE- NTS SOURCE- GOOi r La Chiquit Goodyear Auto Sery VNmar Euro Food® Newcastle Montessori g Q Childress House m NF 121hS El0 0 v NE 121h S Rainier Crest AparP PI �3 cRc mNE 11NG1 m-Highla m NE lxr� 0 s Renton Bible Church Q NE 1pm Sr A - SHEET LIST SHEET # NAME DESCRIPTION 1 C1.0 COVER SHEET & SITE PLAN 2 C1.1 SITE DETAILS 3 C2.0 DEMOLITION & TESC PLAN 4 C2.1 TESC DETAILS 5 C3.0 GRADING &STORM DRAINAGE PLAN 6 C3.1 GRADING & STORM DRAINAGE DETAILS 7 C3.2 STORM DRAINGE PROFILE 8 C4.0 UTILITY PLAN 9 C4.1 UTILITY DETAILS 10 L 1 PLANTING PLAN 11 L2 NOTES & DETAILS 12 L3 TREE RETENTION & REPLACEMENT PLAN AREA INVENTORY; Proposed Surface Area (Including Frontage) Description Area (sf) Area (ac) Project Area 24,239 a556 Driveway nsite) 1,095 0.025 Rooftop (50% Coverage) 5,635 0.129 Patio (Max. Coverage) 595 0.014 51dewalk(Frontage) 2,003 0.046 Roadway (Frontage) 3,736 0.086 Curb & Gutter (Frontage) 292 0.007 Driveway Entrance (Frontage) 321 0.007 New + Replaced Hard Surface (Property) 7,325 a 168 New + Replaced Hard Surface (Frontage) 6,352 0.146 PROPERTY AREA INVENTORY; DESCRIPTION (SF) TOTAL PROPERTY (POST DEDICATION) 14560 TRACT A (STORMWA TER) 3291 LOT A 5516 LOT B 5753 REFERENCES; 1. BOUNDARY AND TOPOGRAPHIC SURVEY BY DA WD EVANS 2. PRELIMINARY ARCHITECTURAL PLANS BY DWI DESIGN. J. ARBORIST REPORT BY ARBOR INFO LLC. 4. GE07ECHNICAL REPORT BY GARY A. FLOWERS. 5. LANDSCAPE PLANS BY GLENN TAKAGI. R-423401 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CURRENT PLANNING SURFACE WATER UTILITY AWeihs 08/08/2023 I JFarah 08/11 /2023 REGIONAL FIRE AUTHORITY r� ^Tod DEVELOPMENT ENGINEERING ° APPROVEDD:', `� IL cthomas 08/04/2023 oy�<FrNEN�� NJanders 08/04/2023 DATE: SHUM SHORT PLAT 05/23/23 CIVIL CONSTRUCTION PERMIT FIELDBOOK:___ PAGE: COVER SHEET & SITE PLAN DRAWING NO: .0 1157 QUEEN AVE NE, RENTON, WA. 98056 SHEET: 1 OF: 12 N d) O O N �, u LO O O N co N 1 0 W I- F ACL 0, CURD 6' CEMENT CONCRETE _ _ 112'R. 1-R S'DEWALK RAMP - - 6 1 rI- 51l2' 1- VARIES OR LANDING FROM t' R 124 6' TOP OF 1 1 r1' R ROADWAY 34' PREMOLDED t JOINT FILLER - CEMENT CONCRETE I m PEDESTRIAN CURB r AT SIDEWALK RAMPS AND LANDINGS T FACE OF ADJACENT CURB CEMENT CONCRETE 6 Mr - TRAFFIC CURB AND GUTTER SEE DEPRESSED CURB DETAIL THIS SHEET FACE OF ADJACENT CURB 1.20 TOP OF 6 17 - -- FLUSH WITH GUTTER , 1• 112'H. ROADWAY PAN AT SIDEWALK 2• 1 RAA1P ENTRANCE 1.12 124 �/ 1 TOP OF 112-R. ROADWAY 1 DEPRESSED CURB SECTION 1° AT RESIDENTIAL DRIVEWAYS ONLY, f FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104 2 - 6- - DEPRESSED CURB SECTION FACE OF CURB AT SIDEWALK RAMPS - -617- 112 _5 _I 17R, 1•R FACE OF ADJACENT CURB F TOP OF ROADWAY • P R '1• • GUTTER SURFACE T J PREMULOED JOINT FILLER t E FULL -DEPTH 1 R _ 6 ,14' EXPANSION JOINT 1R. CEMENT CONCRETE TRAFFIC CURB DEPRESSED CURB DETAIL AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS GENERAL NOTES 1. See stanOarO plans 102 and 101.1 for a b expansion and contraction )ant Waang 2. Expanuon joint shall be full depth. 3/B' Un.) premoldcd Joint filter 3. For Depressed A1ono:i(hc D-way Curb S curter Section, see Stardard Plan 104 2 • PUBLIC WORKS - STD. PLAN 101n CEMENT CONCRETE CURBS DEPARTMENT SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT NW 1/4 NE 1/4, SEC 09, T 23 N, R 05 E. W. M. I I 3/8' PRFJ.IOLOED JO,NT FI BEE Na[E2 /BRA X S/B"D DUMMY JOINT SEE NOTE LCEMECONCRIETE L CUREI As [SOME 41 EOGLULTAIL 10 t �Cy�•.; - LEVELOEWAt1(10.46VEASE 1'-S 1'-T 3S-(.NIP0.ENOLDED JOINT FM1IER EDGE ivPTCAL 1YNERE APFUCAULL C`r=- Vr OMaINCLUD01WSED ROU 'NO FORCURB DETASS _I%% BEE STDPIJW1Di ,Fn _ ;- SING ROAGwAT �. •� sr).• •• �SNEONOCK SASI SEE RAISED I--------- «cRvanED"FA0W 1'•E' ISOMAIX DETAIL -Tm3 SIZE `TYPICAL IINOER TD I2011 EiCSTq ALLCUT s1oE1YALK 10 9:x MOOFIEp PRO, IOa MN ILPPACT $ ] WITH RAISED EDGE ENGIlISSRIOW EWWWANT BY ENGINEER) TYPIGL UIIDERALL EURe. VT eM 0. RYP.1 CUTTER A SIDEIYALIL CSTt UNDER (/ CURS A GUTTER To BEE' 1N109"S OR 1 L I.S% F6EGE 6TD Fui1101e MATCH EXISTING ROADWAYCRUSFEO ROCK %N GO, B+LI C W HICHEVER LS GREATER ITYP FOR HNSTFF •. ALl CURIF A GUTTFRI IF `1, 1 FINISHED GRADE 1 %a BELW! 1J TOP OF CONCRETE SURFACE r-r WOEWALK ADJACENT TO CURB MIN T•E' 1'•E' RO DING VrON)W(TY►I i ` FOR CURS DETAAS �2071 1JI% _ / SEESrO PLAN t01 BRIDGE OAPmESTIING.• .•• - A" "I LNG 4Y" FOR WRB OEtAIIsE('1T TO CURB (STEEP FILL SLOPES) DRIER -SEE SIDEWALK SrLSTD PLAN 101 CMONTRACT PUNS ALL OR WRIER J I 1?ON) R iTYPI -- Fl t/5N J J SKNEWALX 1 5% a ••• Ts faT R VERT CAL WALL- SEE OETAA. 1D' PM PREM LX:G JOINT "ELLLLEA ADJACENT TO CURB AND RAILING OR WALL PRkT�A10glDEO JOINT F4ER FOR SIDE DUFFER STAID TRLATMEN-r SDEWµK SIDEWALK ADJACENT TO WALL DETAIL (SEE NOTE 101 SID V ANK 5tc11G s 1?IBN)R , I FOR CURa CETAAS 1 S% 1 a%AaN SEE STD PUN 101 \':�� ^Mp ORMMATCHFEXISIING . D•t•WlocSMOOTH S TROWELEDPERAIETER FINISHEDGAAGLI'INIBELOWTCp OFCONCA\7E1t, SURFACE FOR PLANTING - FLUSII IF PAQ• 1d' S'-� •^` -. CCMGNT CONCRETE CURB \ - (CURB ANDOURLR 9HOMIN) ADJACENT TO BUFFER STRIP l �,-� FEESID 10, SEE 9TD PLAN IDI PLAN � "ayr NOTES - 1. F.wloaf of NO sidewalwall,wa'1e1 - � be the minimum pedostlien COHTAACTNJNJdvr • be the / /�'-- IN 9pEWnL(ONLr►•�'�'e acceslJbio roue ;-,:. hae or vOnlcal e • � .' , end horUontal obstruanns. GraWgf, �� \-\ • : E Access CDYors, JUnctbn Bllxef, // N FULL -DEPTH EXPANSION JOINT NOOTH • ' ' Cable Vauib. Pull Boxm and other �, �-� \' CURB AND SIDEWALK (%IF sm F1AN to IF appu4snances within The sidewalk _ ass- C CONTRACTION JOINT must be Hush with Surface, and rnimI& ` '44- gmde of the sid-11, JOINT AND FINISH DETAIL -- 2. Monolithic Cement Cottle Curb and •e • •,, a x4'k'o sidewalk Is notpermmed In new For alter referenced NOTES see q , consin.Imlon. Wren replacemsnt work STO PLAN 104.2. ' � • necessUatet a Monollmic Cemllm Concrete Curb bDIId per WSDOT mill. DE :DINT FILLER S'andard Plan F-30.10-Q3. Paved surfaces must COmply With STD PLAN 102.1 as applicable. E FULL -DEPTH 3. Concrete to be 4.000 PSL EXPANSION JOINT - STD. PLAN 102I;-i, • PUBLIC WORKS CEMENT CONCRETE DEPARTMENT SIDEWALK I Coll 17 n W INtkl_.--- _EXISTING ASPH! PAVEMENT SAWCUT (SEE NOTE 2) ARTERIAL STREET MINIMUM 7" HMA (or ACP Class 8) (SEE NOTE 1), OVER 6" CRUSHED ROCK RESIDENTIAL STREET MINIMUM I 4" HMA (or ACID Class B) (SEE NOTE 1). OVER '6 CRUSHED ROCK NOTES: 1. MUST MATCH EXISTING THICKNESS IF GREATER 2. SAWCUT SHALL BE POSITIONED 1' 0" BEYOND EDGE OF DAMAGED PAVEMENT. 3. THE INTENT OF THIS DESIGN IS TO DESCRIBE PAVEMENT PLACEMENT AT THE GUTTER FACE. SEE STANDARD PLAN FOR CEMENT CONCRETE CURBS, STD. PLAN - 103 a PUBLIC WORKS CURB AND GUTTER � PPROPL D: DEPARTMENT REPLACEMENT DETAIL. Z 4:` o ATE 1 701 2 701, 1 3 102 4 703 - O SCALE. NTS - O SCALE: NTS , SCALE. NTS SCALE. NTS w�wFinauoa�a%.utwwl_ ._ � Fa[[NDrte. 11 Rle[wtEu i DRAlwAr ICgRMD MR I'D 1r 111*a IaF nMJIN la» cD Icac a E �6 ! 1 C � M[ratas L 4 5 {rt cT1oN JDNI FFF MJIf l C(AeMi epN{FET[ our NnT«1J»ti a e1Km♦wTnA uoF[ irnr 1 Gee NDrt K X.-peNTRACi4F LAN IE[!*DhM'" roll PLAN VIEW ❑:IFaeNCC MfLOR IJAx �` ` nog;:+IX w�A11 LO� v.aaf - ISaE r:dk"io " a s� IJU a[ rot` a IT1R L nMM1 E'r��iE a•r IN-$s�Ei,:•a Fc,rnn sapaYA imstnlR°i�t'n Itr•. SECTION / � aWr�tnea ELt2rEHlOPe fIFJMNLwcrJIRAr[m ` k. ,r= I• 1._. -. Itivib. OD 1I FaaIRwW T 1 �1 TYPE RIB - ISOMETRIC VIEW (RESIDENTIAL WITH BUFFER) CENENT CONOKM calm a oulr[R Pell NOR, V For NOTES STD PLAN 104.2 STD. PLAN - 104.3 PUBLIC WORKS' CEMENT CONCRETE DRIVEWAY DEPARTMENT ENTRANCE - TYPE RIB nP,e„,,�,M,yN1� 5 1 04. 3 C1.0 SCALE. NTS Gre" Lrnmerman, Public WONk% Administrator ...{I ,' I MINI ,• VAR S MIN MIN I MIN SPSPECIAL_NOTECIE IN THE EVENT TRANSVERSE PATCHES EXIST ��E•��gII WITHIN THE AFFECTED STREET, THE LENGTH III 111 OF THE PATCH SHALL BE EXTENDED TO INCLUDE ANY EXISTING PATCH WITHIN 10 FEET OF THE EDGE Of THE PATCH REQUIRED FOR THE NEW CROSSING AND ANY I I SUBSEQUENT PATCH EDGE WITHIN 10 FEET f OF THE EDGE OF THE SECOND PATCH AND I I 50 ON LIP TO A TOTAL OF 300 FEET. TRAFFIC FLOW 11 I 2" HMA I) 2" TO e" HMA I lII 6 5' MIN. 2" DEPTH OF PLANING OR SAWCUT AND REMOVE VARIES. 6.5' MIN MIN I MIN VARIES MIN I MIN 2" SAWCUT AND REMOVE OR PLANE. SEAL WITH AR-4DOOW (EACH SIDE) 2" HMA SAWCUT AFTER BACKFILL (EACH SIDE) WIDTH OF TRENCH AS REWIRED BY SIZE PROPOSED IMPROVEMENT (SEE WSDOT STANDARD SPECIFICATION 2-09 4) PLUS AN ALLOWANCE FOR ANY SHORING. SHORING, IF NEEDED. SHALL MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATION 7-08.3(1)8 TRENCH WIDTH FACE OF GUTTER OR EDGE OF PAVEMENT CENTER LINE OR LANE LINE DEPTH OF EXISTING PAVEMENT ` 2- - 6" MIN, HMA (SEE NOTE 2) 6" CRUSHED SURFACING TOP COURSE (CSTC) (9-03.9(3)) PER WSOOT STANDARD SPECIFICATIONS, COMPACTED TO 95% MODIFIED PROCTOR, CSTC, BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19), GRAVEL BORROW (9-03.14(1)) PER WSDOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEOTECH REPORT. COMPACTED TO 95X MODIFIED PROCTOR PIPEZONE BEDDING. MATERIAL- SEE STANDARD PLAN 1TO1 FOP Nn TFS, SEE STANDARD PLAN 110.1 TYPICAL TRANSVERSE PATCH FOR PLAN PUBLIC WORKS FLEXIBLE PAVEMENT OR RIGID aA i1 DEPARTMENT PAVEMENT WITH OVERLAY FASy1 ••• 6 1 1O C1.0 SCALE,NTS W 05/23/23 NO. REVISION J Lt VARIES: 4-5' MIN. LANE LINE MARKING SAWCUT AFTER BACKFILL DEPTH OF EXISTING PAVEMENT 2" - 6" HMA (SEE NOTE 2) )' 1' EDGE OF PAVEMENT, EDGE OF CURB & GUTTER, OR MIN. MIN. CENTER OF LANE MARKING 2" HMA (SEE NOTE 2) 6" CRUSHED SURFACING TOP COURSE (CSTC) (9-03.9(3)) PER WSOOT STANDARD 2" SAWCUT AND REMOVE SPECIFICATIONS. COMPACTED TO 95% OR PLANE, SEAL WITH MODIFIED PROCTOR AR-4000W CSTC. BANK RUN GRAVEL FOR TRENCH BACKFILL (9-03.19). GRAVEL BORROW (9-03.14(1)) PER WSOOT STANDARD SPECIFICATIONS OR NATIVE MATERIAL IF APPROVED IN WRITING BY ENGINEER BASED ON GEOTECH REPORT, COMPACTED TO WIDTH OF TRENCH AS REQUIRED BY SIZE OF0 959E MODIFIED PROCTOR, PROPOSED IMPROVEMENT (SEE WSDOT STANDARD SPECIFICATION 2-09.4) PLUS AN PIPE ZONE BEDDING MATERIAL AND COMPACTION AS ALLOWANCE FOR ANY SHORING. SHORING, IF REQUIRED BY THE WSOOT STANDARD SPECIFICATIONS NEEDED, SHALL MEET THE REQUIREMENTS OF FOR THE TYPE of IMPROVEMENT INSTALLED. EXCEPT: WSOOT STANDARD SPECIFICATION 7-05.3(1)B • FOR STORM AND WATER PIPE, PER STD PLAN 220.0 • FOR SANITARY SEWER, PER STD PLAN 405 TRENCH WIDTH • FOR JOINT UTILITY TRENCH, SAND WITH 95% PASSING A k4 SIEVE AND LESS THAN 5% PASSING A p200 SIEVE NOTES 1. WHEN EXISTING PAVEMENT IN A LANE REQUIRING A FULL WIDTH REPLACEMENT IS BROKEN OR DETERIORATED TO A PAVEMENT CONDITION INDEX RATING OF 70 OR LESS, THE EXISTING PAVEMENT IN THAT LANE, AND FOR THAT DISTANCE SO CLASSIFIED, SHALL BE REMOVED AND REPLACED WITH HMA MATCHING THE DEPTH USED IN THE EXISTING STREET OR THE DEPTH PER CITY STANDARD, WHICHEVER IS GREATER. 2 PRINCIPAL/ MINOR/COLLECTOR, ARTERIAL, & INDUSTRIAL ACCESS STREETS - MATERIAL AND THICKNESS SHALL BE HMA CL J" PG 64-22 AND MATCH EXISTING THICKNESS AND IN NO CASE LESS THAN 6". RESIDENTIAL ACCESS STREETS - HMA CL J" PG 64-22. THE THICKNESS SHALL BE THAT OF THE EXISTING PAVEMENT SECTION AND IN NO CASE LESS THAN 4". 3. WHEN THE "SAWCUT AFTER BACKFILL" ENCROACHES INTO AN ADJACENT LANE, CURB & GUTTER OR SHOULDER, THE AFFECTED LANE SHALL BE PLANED AND OVERLAID WITH HMA FULL WIDTH, THE CURB & GUTTER SHALL BE REMOVED AND REPLACED, OR THE SHOULDER SHALL BE PLANED OR REMOVED AND OVERLAID WITH HMA 4. IF TRENCH UNDERMINES EXISTING SIDEWALK AND/OR CURBS, THEN THE SIDEWALK AND/OR CURB SHALL BE REPLACED FROM EXPANSION JOINT TO EXPANSION JOINT S. IF TRENCHING THROUGH EXISTING DRIVEWAY OR SIDEWALK RAMP, THE DRIVEWAY OR SIDEWALK RAMP SHALL BE REPLACED TO MEET ADA STANDARDS TYPICAL LONGITUDINAL PATCH 31'D. PLAN - 110.1 0 Fri PUBLIC WORKS FOR FLEXIBLE PAVEMENT OR DEPARTMENT RIGID PAVEMENT WITH OVERLAY )� J BY I DATE SURVEYED_ DESIGNED: SIC DRAWN: cc CHECKED: sc A P P R APPROVED: sc 7 1 1 0. 1 C1.0 SCALE.' NTS SCALE: NTS ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL. NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M R-423402 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING ` IL NJanders 08/04/2023 DATE: SHUM SHORT PLAT 05/23/23 CITY OF I;R RENTON CIVIL CONSTRUCTION PERMIT FIELDPAGE: OK:--- PAGE: SITE DETAILS SITE N0: Planning/Building/Public Works Dept. C1.1 1157 QUEEN AVE NE, RENTON, WA. 98056 SHEET: 2 OF: 12 N N m C) LO N �J LO C) C) N N 1 n rr Lu n Z O I- U I- C/) Z O U U I- J n O C/) O N U w Q z J 0 10 HORIZONTAL SCALE SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT NW 1/4 NE 1/4, SEC 09, T 23 N, R 05 E. W. M. 1 � 1 SHED ON CONC SLAB I I \ 6"DEC /°A 1FENCE�.5' WOFP/L o CLEARING LMTS x \ / AT PROPERTY BOUNDARY >NOPY \ \ \ / 30"F UNLESS OTHERWISE NOTED = (TYP) \ II x \ I I 18"F \ oA 87'59'50"W 111.12' ` FO ND 2'REBARA D ^ I O < SF T _ SF ��������w��� k AP AT GRA T 947 ro C /' - - "MHT947 -1-� , 10.7' � `� � E. 0.1' v �s V � � � - - - I ^09-J2-21 /� \ FOUND 1/2" REBAR AND x I ry ` 4.8' A , , CAP IN 5" X 5" CONIC I A �00 , "MHT 9470" ss ss r-+ x \ x •/ I \ \,f E. 0. 1' I \I 14 F t • \, 09-02-21 ` I I REMOVE TREE, TYP. \ xcf) ����� x 000 o..F j I -1 , v � x �` I U I U 1 � 60 MA I 12"DEC I / I � 1 I I Ic 1 TEMPORARY TREE I 1 3 3' PROTECTION U 1 26"F I I FENCING, TYP. I I I �� IaI x I II _ 7 Z N I I/ � xl � � i El- I .3L. 0 F , I I cn I � I , x CATCH BASIN INSERT, TYP. I I / -OP `I 1 '` ������ x l w T-12 _ II 6.3"DFIR J II I�I N I rr 100.0, x 1 cf) s s _ 1 O _ � 0 0 1 - � -' 1 x I - w x OO C SSMH 1 �x _ ,- ~♦ D D D TOP 434 25 �♦ 20 • � 24"F I I 08"DEC(2) I I C (W), 8" CONIC (N), a Y I -I' ♦♦ I I i I I --m 8" CONIC (S) ; 2 CENTER CHANNEL o 1 x ELEV.425.43 - _ WV �5 STABILIZED 1 I 1 I I I I I I CLEARING LIMITS TO AVOID ®Wv CONSTRUCTIONx 1 1 ENTRANCE I I I I TREES PER ARBORIST II � � 1 I I I I I I RE�OP, T CONTRACTOR TO x MINIMIZE GROUND I 1 \ 1 I I I I I DISTURBANCE BEYOND 1 s°F 1 I I I I THESE LIMITS, TYP x X I - J s�• �; � �'--� I J 011 \ I CD --x 1 , l o TEMPORARY SlL T FENCE, TYP ® I loor 4%* ` y` FENCE CROSSES P/L A ,\ I I I sO /n Imo` o ►�=_� ���_ __ �yren■■ISF��� 10M--\ x � 9.8' Aso ♦ � 1yl i L'� 5' T L L IN FENCE0.;2's.C=P/L ^A' L_ N87°594 1� _"` ��;- I�� r. ■ , FOUN� PFAPF ,4"I 'v �? u. ..� i X REBAR CEDAR HEDGE xv 0 W. 0.5' I 0.5' 09-02-21 CATCH BASIN DO I ' o TOP 433.33 co 6" CONIC IE 432.30 (IN-W) 8" CMP IE 431.28 (OUT-S) CATCH BASIN DEMOL/T N & TESC PLAN TOP 433.61 ILL.�-L�. E.• 1„=10, ~ I I l.`" !/l `Nl(` IC A']7 ')/1 /(ll IT C\ SCALE. Q 05/23/23 s: x x SURVEYED: SCALE: DESIGNED: 1 "=1 0' Sc DRAWN: cc ONE INCH CHECKED: AT FULL SCALE `SC' IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY SC i JTJIR VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M I � . TESC LEGEND; a x REMOVE TREE 0 0 STORM DRAIN PROTECTION INSERT T-X TREE NUMBER (PER ARBORIST) v SF - - - SIL T FENCE x TEMPORARY TREE PROTECTION FENCING 0 ■�������■ CLEARING LIMITS pO pO pO STABILIZED CONSTRUCTION ENTRANCE I x [j] DEMOLITION & TESC CALLOUTS; 1. PROTECT EXISTING FENCE (TYP). 2 DEMOLISH EXISTING FENCE, TYP. PROPOSED FENCING SHALL BE LOCA TED OUTSIDE OF THE PUBLIC RIGHT OF WAY AND DEMONSTRATE COMPLIANCE WITH THE MAXIMUM FENCE HEIGHT REGULA TIONS. J. CATCH BASIN INSERT PER CITY OF RENTON STD. PLAN NO. 216.30, TYP (SEE DETAIL 1, SHEET C2.1). 4. SIL T FENCE, PER Cl TY OF RENTON STD. PLAN NO. 214. 0, TYP (SEE DETAIL 2, SHEET C2.1). 5. STABILIZED CONSTRUCTION ENTRANCE, PER CITY OF RENTON STD. PLAN NO. 215.10 (SEE DETAIL 3, SHEET C2.1). 6. TEMPORARY TREE PROTECTION FENCING, PER LANDSCAPE ARCHITECTURE PLANS, TYP (SEE DETAIL 4, SHEET C2.1). a DEMOLITION & TESC NOTES; 1. REFER TO LANDSCAPE ARCHTECTURE PLANS FOR ADDITIONAL INFORMA TION ON TREE PROTECTION (SEE SHEETS L 1 AND L2). 0 2. PRIOR TO BEGINNING ANY CONSTRUCTION, COORDINATE INSTALLATION OF TREE PROTECTION FENCING AND ANY GRADING/SOIL IMPROVEMENTS WITH THE GENERAL CONTRACTOR, CITY AND OWNERS REPRESENTATIVE PROJECT ARBORIST. J. PROJECT ARBORIST BE ON SI TE TO OBSERVE GRADING OPERA TIONS IN THE WCINI TY OF x TREES TO REMAIN. 4. FOR ADDI TIONAL TESC MEASURES IN THE QUEEN A VE NE PUBLIC RIGHT -OF- WA Y, SEE SHEET C3.2, TYP. 5. WINTERTIME EROSION CONTROL IS REQUIRED FROM OCTOBER 1 - APRIL 30. 6. THE SITE SHALL BE IN COMPLIANCE WITH EROSION CONTROL AS DEFINED IN APPENDIX D OF THE 2022 RSWDM. THE PLAN REPRESENTS THE MINIMUM EROSION CONTROL ELEMENTS IDENTIFIED IN DESIGN, HOWEVER, ADDITIONAL ELEMENTS MAY BE REQUIRED. 7. ADDITIONAL TESC NOTES, PER CITY OF RENTON STD. PLAN N0. 268, TYP (SEE DETAIL 5, o SHEET C2.1). RECOMMENDED CONSTRUCTION SE47UENCE; 0 0 0 SSMH TOP 432.03 K IE 427.63 (8" BOTTOM ST ELEV. 427.6E NO CHANNE Adx%kCITY OF mimK RENTON • Planning/Building/Public Works Dept. 1. SCHEDULE A PRE -CONSTRUCTION MEETING WITH CITY ENGINEERING DIVISION. TWO DAY (48 HR) NOTICE IS REQUIRED. 2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROL NOTES. J. CALL FOR UTILITY LOCATES. 4. INSTALL TESC MEASURES AS SHOWN AND MAINTAIN DUST CONTROL WHILE PREVENTING DISTURBANCE OF ANY AREAS OF VEGETATION OUTSIDE THE CONSTRUCTION ZONE. 5. HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF RENTON CITY ENGINEERING INSPECTOR. ALL TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE CLEARING. EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR DEVICES SHALL BE MAINTAINED UNTIL PERMANENT VEGETA TION IS ESTABLISHED. 6. DEMOLISH EXISTING STRUCTURES, BUT EXISTING FOUNDATIONS TO REMAIN. 7. REMOVE EXISTING DRIVEWAYS AND DRIVEWAY APPROACHES. 8. ROUGH GRADE SI TE AS REQUIRED TO INSTALL DRAINAGE FEA TURFS. 9. CLEAR, GRUB & ROUGH GRADE SITE. REVEGETAIF DISTURBED AREAS NOT SUBJECT TO ADDI TIONAL SURFACE DISTURBANCE IMMEDIA TEL Y AFTER ROUGH GRADING. (OTHER EXPOSED AREAS SHALL BE STABILIZED PER EROSION CONTROL NOTES). 10. INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS, INCLUDING FRONTAGE IMPROVEMENTS. 11. STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO REVEGETA TION OF ENTIRE SIIF 12. ESTABLISH LANDSCAPING AND PERMANENT VEGETA TION. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE STABILIZATION AND APPROVAL BY CITY INSPECTOR. R-423403 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CURRENT PLANNING AWeihs 08/08/2023 DEVELOPMENT ENGINEERING % NJanders 08/04/2023 DATE: SHUM SHORT PLAT 05/23/23 CIVIL CONSTRUCTION PERMIT FIELDBOOK:___ PAGE: DEMOLITION & TESC PLAN DRAWING NO: 1157 QUEEN AVE NE, RENTON, WA. 98056 SHEET: 3 OF:12 N L0 C) N �, u O O N a J LO O 0 N 1 I5- L rr W n Z O I- U I- Z O U J U I nJ n I- O Cl) L T N U Q z J LL 5' MAX DRAINAGE GRATE TRIM GRATE FRAME _ C- OVERFLOW BYPASS BELOW INLET GRATE DEVICE SEDIMENT AND DEBRIS FILTERED WATER SECTION VIEW DRAINAGE GRATE I RECTANGULAR GRATE SHOWN) I RETRIEVAL SYSTEM (TYP.) OVERFLOW BYPASS (TYP ) BELOW INLET GRATE DEVICE ISOMETRIC VIEW NOTES: .RUTECT:GN SHALL BE PRUVDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR !:ONSTRUCTION AREA. UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP 2. "JET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM 3, THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE IBIGD) FOR THE STORMWATER STRUCTURE IT WILL SERVICE 5. THE BIGO SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM IOVERFLOW BYPASS) 6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE GIGO WITHOUT SPILLING THE COLLECTED MATERIAL. 7 PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01,305) 8 ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE.THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE It." STD. PLAN - 216.30 PUBLIC WORKS PPR E ' R DEPARTMENT CATCH BASIN INSERT (GAZ 9/28/2018 1 ]AR 1 2 1 6.30 C -o SCALE- NTS DocuSign Envelope ID: 6EECF5B6-602A.4E4A43436-A317AA636878 EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SL I. ALL THE NOI LS ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT THE APPLICANT OR OWNER. HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER. THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES I. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON- HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANTS CONTRACTOR. 2 THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORM WATER GENERAL PERMIT. IF IT IS REQUIRED FOR THE PROJECT THE APPLICANT SMALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT 3 THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETA)LING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4 THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS. AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN(S)SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWOM) PRIOR TO THE START OF CONSTRUCTION DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SMALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPUCAWDESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT ADDITIONAL MEASURES. SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK-W TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE. PUBLIC ROADS SKLLL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. OR MORE FREQUENTLY DURING WET WEATHER. AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE b WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS. 7 ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING ANDIOR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER. DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SMALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING ANDIDR CONSTRUCTION 0 COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFT I-= CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST THE IMPLEMENTATION, MAINTENANCE REPLACEMENT, ENHANCEMENT. AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT B ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT RAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY 9 THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE. THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE, DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONOMONS THAT MAY SE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS. OVER AND ABOVE MINIMUM REQUIREMENTS. AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 10 APPROVAL OF THIS PLAN IS FOR ESC ONLY IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN. SIZE NOR LOCATION OF PIPES, RESTRICTORS CHANNELS, OR STORMWATER FACILITIES 11 ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL 12 ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON IOCTOBER 1ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1 ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E G , SEEDING. MULCHING. PLASTIC COVERING. ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM 13. WET SEASON ESC REOUIREM ENT$ APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH. UNLESS OTHERWISE APPROVED BY THE CITY. 14 ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS 15 THE ESC BMPS ON INACTIVE SITES SMALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY 16 BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216 30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION 17 AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENTA ADEN WATER INTO THE DOWNSTREAM SYSTEM 18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINK GRADE OF THE PERMANENT FACILITY 19 AREAS DESIGNATED ON THE PLANIS) CONTAINING EXISTING STORMWATER FACILITIES OR ON -SITE BMPS (AMENDED SOILS. SIORETENTION. PERMEABLE PAVEMENT. ETC ) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION 20. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST). ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW 21. PRIOR TO FINK CONSTRUCTION ACCEPTANCE. THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITE. ALL ESC BMPS SMALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON -SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED AT A MINIMUM. DISTURBED AREAS SMALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINK APPROVAL MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST 22 ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROOKERIES OUTSIDE of ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 268.00 PUBLIC WORKS DEPARTMENT EROSION AND SEDIMENT CONTROL STANDARD PLAN NOTES :45 Aj tGAZ9/28/2018 1 DATE 5 268 -o SCALE- NTS SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT 2'I.2' 14 GAUGE WIRE. OR EQUIVALENT IF STANDARD STRENGTH FABRIC USED FILTER FABRIC NW 1/4 , NE 1/4, SEC 09, T 23 N, R 05 E, W. M. 2' MIN --I�----------- 6 MAX. -� I I I IY MIN POST SPACING MAY BE INCREASED W 4' MIN. TRENCH U TO R IF WIRE BACKING IS USED BACKFILLTRENCH WITH NATIVE SOIL OR 34' TO 1-17Y WASHED GRAVEL 2••R4' WOOD POSTS. STEEL FENCE POSTS, OR EQUIVALENT (TYP I NOTES: 1. CONDITIONS OF USE I 1 SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 12 SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2 DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. ADS (ASTM 04751) 30.100 SIEVE SIZE (0.60-0 )SIT-) FOR SILT FILM 50-100 SIEVE SIZE (0.3D-0.15TIR1I) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM 04.491) 0.02 SEC' MINIMUM GRAB TENSILE STRENGTH (ASTM D4632) LBS. MIN. FOR EXTRA STRENGTH FABRIC ISO 00 LBS, MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION(ASTM D4032) 30%MAX (WOVEN) ULTRAVIOLET RESISTANCE (ASTM D4355) 70% MIN. '2 I9TANDARD 5TREN TH FABRIC REOUIRES WRE BACKING TO INCREASE THE STRENGTH OF FENCE WERE BACKING OR CLOSER POST SPACING MAY BE FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. L.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H,1V 24 IF ATYPICAL SILT FENCE IS USED, THE STANDARD VX4• TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AN - SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE J.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY 32 IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND 13 IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT 3.4 SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 61NCHES HIGH 35 IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. UNLESS OTHERWISE NOTED. DRAWING IS NOT TO SCALE )NTS) STD. PLAN - 214.00 PUBLIC WORKS DEPARTMENT SILT FENCE 9/28/2018 I GAZ DATE 05/23/23 2 2 1 4.00 C -o SCALE- NTS REVISION EylS�WNC' 'Opp R = 2S MIN _"jg e I DRIVEWAYS SHALL BE PAVED TO THE EDGE OF THE RIGHT-OF-WAY PRIOR TO INSTALLATION OF THE CONSTRUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY 2. IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD iCSY \ Yi'' tOQ MIN INSTALL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT. AS PER CITY ROAD STANDARDS 4"-8' OUARRY SPELLS GEOTEXTILE 15' MIN PROVIDE FULL WIDTH OF INGRESSIEGRESS AREA 12' MIN THICKNESS NOTES: CONDITION OF USE I 1 CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. I ; FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION ENTRANCE STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTHMRDTH TO PROVIDE VEHICLE ACCESSIPARKING. BASED ON LOT SIZEACONINGURATI)N 2. DESIGN AND INSTALLATION SPECIFICATIONS Zt A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD- THE GEOTEXTILE SHALL MEET THE FOLLOWING STANDARDS GRAB TENSILE STRENGTH (ASTM 04632) 1NO LBS. MIN. GRAB TENSILE ELONGATION (ASTM D4632) 1 30% MAX. (WOVEN) CBR PUNCTURE STRENGTH (ASTM D6241) 140 LBS MIN. ADS (ASTM D4751) 20451U.S STANDARD SIEVE SIZE) 2.2, DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIOE FOR CONSTRUCTION ENTRANCE STA84LIZATION BECAUSE THESE PRODUCTS RAISE PH LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED. 23 HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPELLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT MEFROM BEING TRACKED ONTO PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT 14. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE 25 WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM. COMPACTED SUBGRADE THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE 3- MAINTENANCE STANDARDS 3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS 12, IF THE ENTRANCE IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE OF SEDIMENT SHALL BE USED THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE. OR THE INSTALLATION OF A WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SMALL DRAIN TO A SEDIMENT TRAP OR POND 3.3, ANY SEDIMENT TKAT IS TRACKED ONTO PAVEMENT SKALL BE REMOVED IMMEDIATELY BY SWEEPING, THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET. EXCEPT WHEN SWEEPING 15 INEFFEC71VE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS. A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS. 3.4, ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. 3.5, IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCES). FENCING SHALL BE INSTALLED TO CONTROL TRAFFIC, UNLESS OTHERWISE NOTTO DRAWING IS NOT TO SIA_E 11, STD. PLAN - 215.10 _ PUBLIC WORKS t"ZX DEPARTMENT STABILIZED CONSTRUCTION ENTRANCE 9/28/2018.1] DATI iI_m�. .... 3 27S.10 C -o SCALE. NTS SURVEYED: DESIGNED: SC DRAWN: CC CHECKED: sC APPROVED: sC SCALE: NTS ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M TREE PROTECTION (for public and private trees) SIGNIFICANT EXISTING TREE f • CONTINUOUS CHAINLINK INSTALL AT LOCATION AS SHOWN ON PLANS 1. MINIMUM SIX (6) y `I FOOT HIGH TEMPORARY1• • OR DESIGNATED LIMIT OF DISTURBANCE OF THE TREE TO BE SAVED. FENCE SHALL COMPLETELY ENCIRCLE TREE(S). INSTALL FENCE POSTS USING PIER BLOCK ONLY. AVOID POST OR STAKES INTO MAJOR ROOTS. MODIFICATIONS TO FENCING MATERIAL AND LOCATION MUST BE APPROVED BY PLANNING OFFICIAL. 2. TREATMENT OF ROOTS EXPOSED DURING CONSTRUCTION:FOR ROOTS OVER ONE DIAMETER DAMAGED DURING CONSTRUCTION, MAKE A CLEAN STRAIGHT CUT TO REMOVE DAMAGED PORTION OF ROOT. ALL EXPOSED ROOTS SHALL BE TEMPORARILY COVERED WITH DAMP BURLAP TO PREVENT DRYING AND COVERED WITH SOIL AS SOON AS POSSIBLE. 3. NO STOCKPILING OF MATERIALS, VEHICULAR TRAFFIC, OR STORAGE OF EQUIPMENT OR MACHINERY SHALL BE ALLOWED OF THE FENCING.NOT • • OR REMOVED UNLESS APPROVED SUPERVISIONBY THE CITY PLANNING OFFICIAL. WORK WITHIN PROTECTION FENCE SHALL BE DONE MANUALLY UNDER THE OF •N-SITE ARBORIST AND WITH PRIOR APPROVAL BY THE CITY PLANNING OFFICIAL. 4. FENCING SIGNAGE AS DETAILED ABOVE MUST BE POSTEDALONG TREE PROTECTION FENCING SCALE. NTS ® CITY OF RENTON • Planning/Building/Public Works Dept. R-423404. IN COMPLIANCE WITH CITY OF RENTON STANDARDS F MENT ENGINEERING �ers 08/04/2023 DATE: SHUM SHORT PLAT 05/23/23 CIVIL CONSTRUCTION PERMIT FIELDBOOK:___ PAGE: T E S C DETAILS DRAWING NO: C2.1 1157 QUEEN AVE NE, RENTON, WA. 98056 SHEET: 4 OF:12 N N d) L0 O N N �, O O O I N N a J QD L O O O O N N 1 n N It LLI I- 75 rr LIJ n Z O I- U Z) rr C%) Z O C) J C) J n rr O (1) O C6 C) w Q z J SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT NW 1/4 NE 1/4, SEC 09, T 23 N, R 05 E, W. M. �T � I / _ / I i 1. 5' p� �I Oa�ti 0 10 2 � ° x I ""*24"F b�° / SHED ON �/ I HORIZONTAL SCALE CONC SLAB I 16"D °A x / \cn I IN\ I SSMH TOP 434.25 8" CONC (N), 8" CONC (S) =R CHANNEL ELEV. 425.43 FENCE 5' IL o N I 18"DEC2/ W. OF P/L A O 10 u FUTURE DRAINAGE COLLECTION \ , l 1 SYSTEM TO BE INSTALLED W/ / TREE CANOPY LINE LINE G DEVELOPMENT OF LOT B (TYP) \ I X \ Aar 307 .O x 432.24 V'� I 18"F/ I PF 4 1.19 \ GN�31. 0 oA EG 4a1.991 I� o / I 1 - . N 87°59� 1 2 - FG 433.11 O TC 432.84 _ _ FL 432.34 2 Oq 43� _� FO ND Zf'REBARA D �� �\ 431 - ------ - - - - - - �� o � }�P AT GRAD U - , "MHT 947 ' � � ---------- c■ a• °, o o E 0.1' \ / . - TRACT A o / r I 09 62-21 v\ ti`' �\ \ (STORM 1FR) 3AR AND430.67 �o TJR 1.67. 2. a + 37 LF OF 12" DI SD a a1 x� • \ \ \ 0 4. 79 (PRI VA 7E) 714"F 1 1.5Z 432 \ \ I ° FUTURE BLDG OUTLINE \ \ �N� SHOWN FOR REFERENCE SD AREA DRAIN 1 ONL Y, TYP. I 1 RIM 431.0 - \ 1 / 6" IE 428.7' 1 • � j2. � � LOT B " a 0 I \i o F A° j ,°� BUILDING PAD 9LF 6" PVC SO I EL. 433.75 ° ® 15.67o (PRIVA TE) ° VANED GRA TE 10 } I FUTURE DR/VEWA Y SHOWN 2� 1 - 10 / \ I ♦ 433 FOR REFERENCE ONLY, I O O a %<, I TrP I I I I I Idlll EG 432.78 EG 433.12 4.3q ® STORM DRAINAGE CALLOUTS; 1. INSTALL STORM DRAIN CATCH BASIN TYPE 1, PER CITY OF RENTON STD. PLAN NO. 200.00, TYP (SEE DETAIL 1, SHEET C3.1). 2. INSTALL STORM DRAIN CA TCH BASIN TYPE 2, PER Cl TY OF RENTON STD. PLAN NO. 201.00, TYP (SEE DETAIL 2, SHEET C3.1). J. INSTALL CONCRETE INLET, PER CITY OF RENTON S7D. PLAN NO. 200.30, TYP (SEE DETAIL 3, SHEET C3.1). 4. INSTALL STORM DRAIN CLEANOUT, PER CITY OF RENTON STD. PLAN NO. 403.1, TYP (SEE DETAIL 4, SHEET C3.1). 5. INSTALL FLOW CONTROL STRUCTURE, PER CITY OF RENTON STD. PLAN NO. 237.00, TYP (SEE DETAIL 5, SHEET C3.1). 6. INSTALL DETENTION FACILITY (SEE DETAIL 1, SHEET 02). INLET PIPES ON N, E & S (1E o = 427.5). INLET PIPE ON W (1E = 427.0). 7. INSTALL VANED GRATE, PER CITY OF RENTON STD. PLAN NO. 204.00, TYP. EG 432.74 EG 433.08 8. INSTALL SOLID LOCKING LID, PER CITY OF RENTON STD. PLAN NO. 204.4 AND 204.5, TYP. 4 2X 9. FOR ADDITIONAL INFORMATION ON THIS STRUCTURE, SEE DETAIL 2, SHEET C3.2. - 10. INSTALL INFIL 7RA 77ON FIL TER (SEE DETAIL 8, SHEET C3.1). " 2 8 11. 24' DIA. ACCESS RISERS (TO GRADE), TYP. (6 PLACES). RIM 432.5' 12. INSTALL FINE SCREEN MESH OVER DOWN -TURNED ELBOW. 12' 1E 425.5' (OUT-S) g SOLID LOCKING LID � O STORM DRAINAGE NOTES; 3 RIM 432.3' 12' IE 429.3' (OUT -SW) 9 1. FOR QUEEN AVE NE STORM DRAINAGE PLAN AND PROFILE, SEE SHEET C3.2, TYP VANED GRA 7E 2. FUTURE, ON -SITE GRADING AND CONTOURS SHOWN FOR REFERENCE ONLY, T1P. EG 32. 71 EG 433.04 4. �x ` J.SURFACE WA TER STANDARD PLAN NOTES, PER CITY OF RENTON S7D. PLAN NO. 267.00 AND 267.10, TYP (SEE DETAIL 6 AND 7, SHEET C3.1). 1 F I � I UTILITY CALLOUTS' 10 LF (TYP) 6" PVC SD ® 0I I I I I I 5%2. 29 (STUB FOR FUTURE BLDG I I I I I EG 432.69 EG 4133.02 a ROOF/FOOLING DRAIN) 15 LF OF 6" PVC SD I I I I 0 2 4.1% I 1 (6' 1E 428.0) (PRI VA 7E) 02.09 (PRI VA TE) II • I I I 11 ° SD YARD DRAIN 2 O O SDCB 5 TYPE 1 i I I i RIM 430.7' O 26"F RIM 431.7 I 1 �4) 6' IE 427.5' (IN-N, S) lI 8LF 6PVC SD ®156% (OUT-E, WINE) I i i I W / (PRI TE)1 1 VANED GRATE W `V 1 - 434 I (PRIVATE) VANED I I II GRATE I I I I I I p °.. LV FG 434.00 A L i i i i 10 \EJ 4 I i I I i I 1 I EG 432.67 EG 4 2.99 fL W 433�f1 x x 10 LF 6' PVC SD ® 2.07o I I I 2. 6 r. 4.0% \ • ���q� a ! -- (STUB FOR FUTURE BLDG I / I � �a 1,5% ��� � f �� a� i ROOF/FOOTING DRAIN) ,: FG 434:30 4 2 r , a c 1 (6' IE 428.0) (PRIVATE) I i i I acn 1 °.cn I� xo . a. .a I l F6.434:MUN 434.60 ii t W I I Z 1 � SSI S ° a• °.. S A 1.59. 2.09 I Ico o S FG 433.E FG 434.20 a 1 I I I I I �`� I I 1 I `EG 432.59 EG 432.87 _ e DETENTION, TRENCH .0� 5 I I 13.2. `� i/ 4.0� DIM. 84 Lx12 Wx5 D 5I I I I - 1 ° w (A=1, 008 SF) 1 X", a a FG=431.5' P I TOP=430.5, -54 ' c r " ,� O I ,� x____ '� 1 12 /E 425.5 �, CONTROL STRUCTURE I I I I � SD YARD DRAIN 3 1 _ _ _ .4 BOTEL. 425.0 RIM 432.3 I I ° RIM 431. 0 Y ♦ 12' IE 425.5' (IN-W) I I I I 6" IE 428.7' (OUT-W) 1 ♦ %° a 12" 1E 425.5' (OUT -SE) I I I I \ l 1 / 8LF 6" PVC SD ® 15.69 w 0 wv 1 ^�(PRIVA 7E) SOLID I I I A o a t o (PRIVATE) VANED GRA lE •wv 1 1 ; °..� LOCKING LID I I I I I I 10 a EG 432.55 EG 432.74 1 d.� 1 LOT A A " 1 I j l I I ti A I r 1.9z l / I BUILDING PAD 7 LF OF 12 PVC SO I I I I ' cn I 1 ' EL. 433.75 2� 0 0. 07 (PRI VA TE) I I I I I I 37 LF OF 12 PVC SD I 1 6"F 1. :.. I I I ® 0.81w. (PRI VA 7E) I I LJ I 1 N87° 9'�. x . xk3 I 1ir o.. 4 °X t o I X 1 XTEMPORARY TREE ♦ I I PR07EC77ON FENCING. �� i I I 1 / a EXCA VA 77ON NOT TO I / 1 EG 433.7/ I ► EXTEND INTO THIS AREA. +� I "�°� a I EG 432 40 \ I 1 ♦ a� EG 433 88 < 1 �, 2 WM " o �i , °EG 433 88 ° G 433.84 , FENCE CROSSES P/L / `�% S11-5 - I a _ '� 5q 04 44 1 1 o I RIM 432.0 x w �° . ° 10 12 LF OF 12" PVC SD \ ° _ 16 l N 12" IE 424.9' (IN-N, NW)(OUT-S) a ® 0.59 (PRI VA 7E) o �b SOLID LOCK/NG LlD =Not#�� < �TMItLI�LF� s = 5' -I 12 1 �� o FEN S. P/L M N87°59'46"W 114.15' RIM 432.0 M CATCH BASIN J TOP 433.33 6" CONC IE 432.30 (IN-W) 8" CMP IE 431.28 (OUT-S) CATCH BASIN TOP 433.61 R" r niki!` IC A00 0A /!ll 1T C\ F U EG� 0 597 EG 4 3.43 09-02-21 I 05/23/23 as \ GRADING & D SCALE. 1'=10' 061 12' IE 428.3' (IN -SE) 4 ° CEDAR HEDGE 12" IE 428.3' (OUT -NW, W/DTF) SOLID LOCK/NG LlD � EG 429.97 27 LF OF 12" D/ SD FG 4J2.62 ® 2.07. (PRI VA 7E) EG 429. 89 EG 431 NA G E PLAN v O RIM 431.8' 7O12" IE 428.8' (OUT -NW) VANED GRA 7E SURVEYED: SCALE: DESIGNED: SC DRAWN: CC ONE INCH CHECKED: AT FULL SCALE SC IF NOT ONE INCH REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY SC I EG 432.26 200 32q '2.03 .63 (8" PVC (OUT-N) BOTTOM STRUCTURE ETC 43 . 5 I I ELEV.427.66 FL 431. NO CHANNEL I I o I N I ° G I VERTICAL. NAVD 1988 • HORIZONTAL: NAD 1983/1991 CITY OF R RENTON Valor DATU M Planning/Building/Public Works Dept. 1. FOR PROPOSED SANITARY SEWER DESIGN, SEE SHEET C4.0, TYP. 2. FOR PROPOSED WA TER DESIGN, SEE SHEET C4.0, TYP. PL/7RACT TRACT/ROW I I 1 1.0' 1 1 I 5.5' j 5.0'- 12' DETEN7ION I 10.0' LANDSCAPING FACILITY 1 DETENTION SECTION A C3.0 SCALE- NTS TRACT/ROW C.L. 0. 5' CURB I SAWCUT 3.5' 5.0' 8.0' 13.0' 7.0' 1 PLANTER DRIVE LANE (VARIES) I 1.5% 29 1 27. VARIES 3�(MAX) 1 1 SIDEWALK I 10. O' LANDSCAPING B QUEEN AVE NE SECTION C3.0)SCALE- NTS C.L. ROW ROW DEDICATION I EXTRUDED 23.0' 1011 CURB 0. 5'- 1 3.0' 13.0' 18.0' 5.0' 1 EDGE OF DRIVE LANE PLANTER/LANDSCAPE PA VEMENT 1 y 1 VARIES 1.59 1 I n I SIDEWALK PIERCE AVE NE SECTION Jv^"""J R-4234 05 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CURRENT PLANNING SURFACE WATER UTILITY AWeihs 08/08/2023 J Farah 08/11 /2023 ' DEVELOPMENT ENGINEERING NJanders 08/04/2023 ' DATE: SHUM SHORT PLAT 05/23/23 CIVIL CONSTRUCTION PERMIT FIELDBOOK:--- PAGE: GRADING & DRAINAGE PLAN DRAWING NO: C3.o 1157 QUEEN AVE NE, RENTON, WA. 98056 SHEET: 5 OF: 12 N Lid O N A, u O O N Q J L0 O O N N co N 1 0 W TM U 41)E 4M4''4►�'�♦ ♦ r. 4' 6', 1 r. OR 24" - ONE 43 BAR \HOOP FOR 6' HEIGHT INCREMENT (SPACED EQUALLY). '.EF NOTE 1 RECTANGULAR ADJUSTMENT SECTION N�A�B �fF 40jF e Y 43 BAR EACH CORNER r i \ I rr n3 BAR EACH SIDE 03 BAR EACH WAY PRECAST BASE SECTION R3 BAR HOOP n3 BARE CH CORNER 18' MIN SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION • PUBLIC WORKS PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN 1r CONCRETE ALL METAL PIPE 15' CPSSP'. 1r STD.SPEC. 9-05-m SOLID WALL PVC. STD SPEC. 9-05.12(1) 15" PROFILE WALL PVC. STD SPEC. 9-05.12(2) is, ' CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: I AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHU.'.N IN THE PRECAST BASE 9ECTKNJ, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.sot 9)I, OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SOLD (E INCHES PER FOOT SMALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20'. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF r MINIMUM TO 2 S" MAXIMUM. PROVIDE A 1.5' MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3 THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET 4 THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN S. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1FF.24V OR STEEPER- 6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SMALL BE GROUTED FULL AFTER THIF INLET HAS BEEN PLACED USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WI I" STANDARD SPECIFICATION 0,20.3(2) 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS. RISERS. AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS 10 FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH 11 ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING ISNOT TO SCALE INS) STD. PLAN - 200.00 APPR DEPARTMENT CATCH BASIN TYPE 1 GAZ 9/28/2018 1 BATE REMOVABLE WATERTIGHT COUPLING OR FLANGE - IF MAX. FOR MAINTENANCE SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT NW 1/4 NE 1/4, SEC 09, T 23 N, R 05 E. W. M. CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204-00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION ITWO SECTIONS MAX I - MORTAR. ITYP) SEE NOTE 5 4- MIN, 26' MAX 1S" MAX FLAT SLAB TOP 96", 120' OR 4C EE NOTE 6 TYP I IMIN 1' MIN2.5' MAFORCING 'O'GRAVEL STEEL. (TYP. ) BACKFIL L FOR PIPE ZONE BEDDING PER WSDOT STD. SPECIFICATION SECTION 9-03.12(3) G W SEPARATE BASE INTEGRAL BASE PRECAST PRECAST WITH RISER NOTEST vu STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LES& 2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3 THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION 4 KNOCKOUTS SHALL HAVE A WALL THICKNESS OF r MINIMUM TO 2.Y MAXIMUM. PROVIDE A 1 5' MINIMUM) GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 5. ALL GRADE RINGS, RISERS. AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04 3 6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR•N•SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED E(XUAL) WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7 MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURERS DIRECTIONS, 8 FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH 9, ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL TMICKNE99 MIN BASE THICKNESS MA%IMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 4W 54' 4.5' ✓E 4r S' 60' 5' B' 48' 8' 72' 6' 8' 60" 12' 1. r 12" 7r 12' 96, r 12' 84' 12' 12T 10" 12' 98" t2' 141" 12" 12' 108, 12' PIPE ALLOWANCES CATCH BASIN PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER DIAMETER CONCRETE ALL METAL CPSSP' SOLID WALL PVC ° PROFILE WALL PVC 48" 24' 3T 24' 30" 30' 54" 30, 36" 30' 36" 36" 613" 36' 42' 36' 42" 42" 72" dr 54" 42' 48" 48' 84" 5A' 1' 1. 48" 1" 98" 60' 72" 50' 48" 48' 120' 66' 84" 60, 48" 48- 144' 78' 9fl"1 60- 48" 48' CORRUGATED POLYETHYLENE STORM SEWER PIPE ISM. SPEC. 9-05.20) STD. SPEC. 9-05, 12(11 SPEC 9-05 1242) STD. PLAN - 201.00 PUBLIC WORKS CATCH BASIN TYPE 2 R DEPARTMENT FOV""' - GAZ 9/28/2018 1 BATE ,4', r. 12'. OR 24' ONE 43 BAR HOOP FOR 6' HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 12" ALL METAL PIPE 15' CPSSP', STD. SPEC. 9-0620 12' SOLID WALL PVC. STD. SPEC. 9,05.1211) 15, PROFILE WALL PVC, STD. SPEC. 9-05.1212) 15' 'CORRUGATED POLYETHYLENE STORM SEWER PIPE .�.,tES SFF4b' E� Tes NOTES: \ \ 1 AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN t71 THE PRECAST BASE SECTION, FIBERS (PLACED IN U� ACCORDANCE WITH STANDARD SPECIFICATION 9.0S WET)). �STS Oct OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION WIRE MESH SHALL NOT BE PLACED IN THE n3 BAR EACH CORNER I KNOCKOUTS- AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 03 BAR EACH SIDE SQUARE INCHES PER FOOT MAY BE USED TOP AND BOTTOM 2. THE KNOCKOUT DIAMETER SMALL NOT BE GREATER THAN ONE R3 BAR 18'. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" ACROSS BOTTOM MINIMUM TO 2.5' MAXIMUM PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PRECAST BASE SECTION PIPE AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3, THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE S 4 THE FRAME AND GRATE SHALL BE INSTALLED WITH THE FLANGE DOWN. 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1 H 24V OR \ STEEPER8. THE STRUCTURE OPENING DIMENSIONS SHALL BE XT MEASURED AT THE TOP OF THE PRECAST BASE SECTION A3 BAR EACH 7. ALL PICKUPHOLES SHALL BE GROUTED FURL AFTER THE CHAS CORNER 18"IMIN INLET BEEN PLACED. USE GROUT TYPE 2 FOR I WITH 03 BAR HOOP SNStiRIN TANDARD SPt�CCATI ION �IN�ZORDANCE 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3 THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS RISERS, AND FRAMES SEE NOTE 1 9. MORTAR SHALL BE MIXED AND APPLIED PER ALTERNATIVE PRECAST BASE SECTION MANUFACTURER'S DIRECTIONS 10 FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. Tt ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAi'. VISIBLE UPON COMPLETION, UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) Aowu STD. PLAN - 200.30 PUBLIC WORKS ED DEPARTMENT CONCRETE INLET GAZ 9/28/2018 1 BATE RECESSED Not ;o Scale LIFT POCKET o o FRAME 3/4" LETTERING `SEWER` -0 1 DIAMETER , 1'-0' 400 o � o � o SEWER (2) BOLT SOC. (ALLEN HEAD) 5/8" - 11 X 15 STAINLESS o a o STEEL REF PART #00981177 �10-112' Tt-3/16" 1SEE NOTE 3 5/8" 1� 1" 1 ,,B 2-1/4 III- 12-3/4� 11" 12- AST IRON RING AND COVER BOLT DETAIL 45' (T/6) BEND SAND OR EXPANDABLE FOAM 4 Pa J~ lXO P PIPE MATERIAL AS SPECIFIED BY THE ENGINEER 45- (1/8) BEND 1 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC No 3698 (PRODUCT NO D0369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY 2 IN UNIMPROVED AREAS, POUR A 8" THICK; Y-O' SOUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER 3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106 STD. PLAN - 403.1 PUBLIC WORK5 8" OR 6" CLEANOUT DEPARTMENT FOR SANITARY SEWER MAIN Martin PBStUCIW26/2020 BD DATE 1 200.00 2 20 1 ,00 3 200.30 4 403, 1 C3.0 SCALE: NTS C3.0 SCALE:NTS C3.0 SCALE: NITS SCALE. NTS 7 MIN CLEARANCE TO ANY PORTION OF FLOW RESTRICTOR TEE INCLUDING ELBOWS r MIN. ELBOW RESTRICTOR, SEE DETAIL AND NOTE 10 - 8' MIN J r MIN. 8' MAX. PLATE WELDED TO ELBOW WITH ORIFICE AS SPECIFIED. SEE NOTE 3 ELBOW RESTRICTOR DETAIL ELEVATION PER PLANS 12' MIN. UNDER PAVEMENT ADDITIONAL LADDER RUNGS (IN SETS) TO ALLOW ACCESS TO TANKS OR VAULTS WHEN CATCH IS FILLED WATER i T I 1 I J i / ANGLE AS / NECESSARY, / SEE NOTE 7 PLAN VIEW FRAME 6 SOLID COVER MARKED •DRAIN" WITH LOCKING BOLTS PER STD. PLANS 2D4-40 AND 204,50 16" MINX. VERTICAL BAR GRATE FOR SECONDARY INLET 6'MIN. DESIGN WATER ELBOW RESTRICTOR. ERFAff SEE DETAIL AND NOTE 10 HANDHOLDS. STEPS. OR LADDE+t PIPE SUPPORTS, SEE NOTE 6 tr (TYP.) 1.5xD f SEE NOTE 9(TYP.) MIN. 2. MN T- I ISOMETRIC I OUTLET PIPE, SEE INLET PIPE NOTES 1 A 5 7 MIN. SHEAR GATE WITH CONTROL ROD FOR INVERT AND CLEANDUTfDRA1N (ROD BENT AS REQUIRED ELEVATION PER PLANS FOR VERTICAL ALIGNMENT WITH COVER) 12' SECTION OF PIPE ATTACHED BY PER STD. PLAN 237.30 GASKETED BAND TO ALLOW REMOVAL 7 12* MIN, WELDED RESTRICTOR PLATE WITH ORIFICE DIA AS SPECIFIED. SEE NOTE t0 SECTION A NOTES: USE A MIMIMUM OF A 54' DIAMETER TYPE 2 CATCH BASIN 2 OUTLET CAPACITY 100-YEAR DEVELOPED PEAK FLOW 3 METAL PARTS PREFERRED TO BE STAINLESS STEEL ALUMINIZED STEEL. OR ALUMINUM ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMEN's • na 4 FRAME AND LADDER OR STEPS OFFSET SO. A CLEANOUT GATE IS VISIBLE FROM TOP 8 CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE- C. FRAME IS CLEAR OF CURB 5. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE OUTLET PIPE TO HAVE SMOOTH O D. EQUAL TO CONCRETE PIPE I D- LESS 114", 6 PROVIDE AT LEAST ONE 3' X 090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL (MAXIMUM T-O' VERTICAL SPACING) 7 LOCATE ELBOW RESTRICTOR(S) AS NECESSARY 70 PROVIDE MINIMUM CLEARANCE AS SHOWN 8. LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER. 9. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR IKOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING. TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 70 IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED. UNLESS OTHERWISE NOTED. DRAWING IS NOT T05GLE (NISI STD. PLAN - 237.00 • PUBLIC WORKS FLOW CONTROL STRUCTURE - y V DEPARTMENT RESTRICTOR TEE Martin Pastucha 8/13/20 90. DA7E 5 23 7.00 C3.0 SCALE,NTS DocuSign Envelope ID: 3SIB34D3-7EOA476C-ADB34329PFEOC108 SURFACE WATER STANDARD PLAN NOTES: I 1 I ' lT 4A. ' - AI NL- I - - %TH I"I IV I' .. F, I 'v -1: HE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INL.0 . URA; LJ IN 'rl' U 2 J! _ L I'.A .,� I AL. L NU U c L ,. !� C t � C L +'ROJECT THE APPLICANT OR OWNER. HEREBY REFERRED TO AS APPLICANT MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER. THL APPLICANT SHALL NOT RENUMBER NOR EDITTHE REMNNING NOTES. IF ADDITIONAL ARE NEEDED FOR SPECIFIC ASPECTS. THEY SHALL BE ADDED AFTER THE '.;URFACE WATER STANDARD PLAN NOTES BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS. A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANTS CONTRACTOR THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION -I ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC). AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY 4 APPROVAL OF THE ROAD. GRADING, PARKING, BUILDING. AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER. SEWER. GAS, ELECTRICAL ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES. VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. _ A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS - THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABUSHED BY FIELD SURVEYOR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANTS CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN. AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS-BULT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EXISTS. VERTICAL DATUM SHALL BE NAV0 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH). UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK. DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS. R ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SMALL BE COMPACTED TO 95%MAXIMUM DRY DENSITY PER SECTION 2-03.3000 - COMPACTION AND MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERM1tEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH BACKF IU •_ sllnu SE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY - OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRANAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON T"E -= APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS 1;1 ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY. THE EXISTING MANHOLES. CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED 1 I ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CRY. 12 ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL. AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220 00,220 10, AND 22020 13 STEEL PIPE SHALL BE ALUMINIZED. OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 51NSIDE AND OUTSIDE. 14 ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN 204.10. 20420. 2D4.30, 20440. AND 204 50. STRUCTURES SHALL HAVE. • RECTANGULAR OR ROUND. SOLID LIDS WHEN NOT COLLECTING RUNOFF. AND OUTSIDE OF THE ROADWAY. • ROUND. SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY. BUT OUTSIDE OF THE CURB/GUTTER LINE • ROUND. SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CRY. PRIVATE STRUCTURE LIDS OUTSIDE PUSUC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO - IF, BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4 1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDAI I-, LIDS OF MANHOLES/CATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING ALL MANHOLE/CATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN 17 ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 31 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH 6 26 7.00 C3.0 SCALE,' NTS UNLESS OTHERWISE NOTED DRAWING 6 NOT TO SCALL : `. STD. PLAN - 267.00 PUBLIC WORKS SURFACE WATER STANDARD PLAN flwoil4 Dy. DEPARTMENT NOTES (1 OF 2) artin Pastucha8/13/zozo 1 a:a DATE 05/23/23 DocuSign Envelope ID: 3B1B34D3-7EOA476C-AD834329FFEOC108 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PUN SET. ALL THE NOTES ON THE LIST MA) N� 7 1 L F i A'I: I (, C'L LI' •'ROJECT THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER. THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAIN64G NOTES- IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE :SURFACE WATER STANDARD PLAN NOTES 18 ROCK FOR EROSION PROTECTION OF ROADSIDE OITCHES. WHERE REOUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT AND SHALL MEET THE FOLLOWING SPECIFICATIONS • 4-8INCH ROCK 140 - 70% PASSING; • 2 - 4 INCH ROCK 130 - 40% PASSING; AND • LESS THAN 2INCH ROCK 110. 20%PASSING. I D. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE. UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BAPS 20, THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED, A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED'STORM' OR'DRAIN' SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00 21, ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDEL TO THE CITY PRIOR TO CONSTRUCTION 22 ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266.DD CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS ANO.IOR PAVEMENT 23 ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.30) OF THE WSDOT STANDARD SPECIFICATION:- AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED 24 FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED. ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOLI. EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLA": 28400 25 ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION ANMOR LIABILIT , CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION 26 ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT- FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY Of THE PUBLIC. AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY 27. PROJECTS LOCATED WITHIN THE CITSHALL COMPLY AQUIFER PROTECTION AREA (APA) SHACOMPLY WITH SPECIAL REOUIREMLM 160E THE RENTON SWOM AND AQUIFER PROTECTION REGULATIONS (RUC 4-3-050) 28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASINiMANHOLE LIDS, CLEANDUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH. INTERSECTIONS U, STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NONSKID LID PER ADA REQUIREMENTS 29. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT. 30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1 A2 OF THE RENTON SWOM 31. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO TH- PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE. THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1.D00 SQUARE FEET OF PERMEABLE PAVEMENT, IF THIS TEST IS NOT CONCLUSIVE. THEN ANOTHER TEST PER ASTM C1701 SMALL BE CONDUCTED, FOR LARGE AREAS IF G., PARKING AREAS). TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. 7 267. 1 0 C3.0 SCALE.' NTS UNLESS OTHERWISE NOTED, DRAWING 6 NOT TO SCALL '. STD. PLAN - 267.10 PUBLIC WORKS SURFACE WATER STANDARD PLAN +br»4w: DEPARTMENT NOTES (2 OF 2) artin Pastuchg/13/zozo 8:48 •"•^fS•AFl7B46490 OAT[ FLOW 6" MiN PIPE - INFILTRATION FILTER SECTION NTS LAST REVISED: 01/2017 12" MiN PIPE 6" MIN PIPE FLOW WiRE MESH BASKET 1. PRODUCT SHALL BE ORENCO S06`1236-6L STORMWA TER CATCH BASIN OR EQUIVALENT. 2. PLACE THE INFIL TRA TION FIL TER UPSTREAM OF THE INFIL TRA TION SYSTEM (EX. DRYWELL, INFILTRATION TRENCH, ETC.). 8 INFILTRATION F/LTEl4 c3o SCALE. NTS R-423406 IN COMPLIANCE WITH CITY OF RENTON STANDARDS SURFACE WATER UTILITY J Farah 08/11 /2023 DEVELOPMENT ENGINEERING NJanders 08/04/2023 ' SURVEYED: _ SCALE: NTS VERTICAL: NAVD 1988SHUM HORIZONTAL: NAD1983/183/1991 - ® CITY OF SHORT PLAT CIVIL CONSTRUCTION PERMIT DATE: 05/23/23 DESIGNED: SC FIELDBOOK:--- RENTON PAGE: --- DRAWN: cc ONE INCH DATU M GRADING & DRAINAGE DETAILS DRAWING N0: CHECKED: SC AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY Planning/Building/Public Works Dept. 1157 QUEEN AVE NE, RENTON, WA. 98056 C3. 1 NO. REVISION BY DATE APPR APPROVED: SHEET: OF: 6 N L^N O C) N A, LJ LO O O N N I Ir n co N 0 Lu I5- L W n z O U F- cn z O U J U Q J n rr O C/) 5 cn N C'7 U a z J W(D) A� 0 >>. N OP 450 440 430 420 O O STA 1.9+.96.7.3, 4. R' l T SDCB #4, TYPE 2-48" RIM 432.5' 12" IE 425.5' (OUT-S) SOLID LOCKING LID. FIELD VERIFY SUFFICIENT SEPARATION BETWEEN UTILITIES IS FEASIBLE. REPORT DISCREPANCIES TO ENGINEER. W(D) W(D) - - W(D) - W(D) O 6 STA 1.9+.91.94 19 0' l T 00, SD INLET 12 RIM 432.3' 12" IE 429.3' (OUT -SW) VANED GRATE X 126 LF OF 12" PVC SD- I ® 0.59 (PUBLIC) W(D) - SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT NW 1/4 NE 1/4, SEC 09, T 23 N, R 05 E. W. M. STA 1R+70.4 4.R' / T SDCB #3, TYPE 2-48" RIM 432.0' 12" IE 424.9' (IN-N, NW)(OUT-S) SOLID LOCKING LID LL X LLN�w 02,=�o N wmw= -4- - jT K? A I 2 �® SD ■ -�- x -SS-ss sin dSs ss- -ss ss ss cc o 0- BP BP BP BP BP BP 0 oQ �► � \ UO I ' W5 ozo. ?8X mo o L woox2 r� I ----_---------------F�22 ILL! I --- P L-- ------� I I, N -- jllltll S X �_ A/77 CCESS RISER, TYP o,. CTA 1010-^ 77 A R' l T CTA 1 Ri 7/1 QO A R C l T SDCB 12, TYPE 2-48" RIM 430.5' 12" IE 424.3' (IN-N)(OUT-S) SOLID LOCKING LID 113 LF OF 12" PVC SD ® 0.57. (PUBLIC) O \d0 OP � OP SD SD -�v P SD -gP -gP P STA 1 R+70. R.9, 19. 0' 1 T O O SD INLET #1 RIM 431.8' 12" IE 428.8' (OUT -NW) - - VANED GRA TE I nr� ♦ � . cn nn i n� J r SDCB #I, TYPE 1 (EX) RIM 429.0' (COR) 'u- 423. 12 1E 423.7' (IN-N) 113 LF OF 12" PVC SD ® 0.59 (PUBLIC) o I EX. 12" SD o 00.57. I - SD SD SD SD IL I I I I I ..J SDCB 14, TYPE 2-48" RIM 432.5' 12 IE 425.5 OUT-S) SOLID LOCKING LID SDCB 13, TYPE 2-48" RIM 432.0' 12 IE 424.9 IN-N, NW(OUT-S) X. SIDE SEWER O EX. SIDE SEWER SOLID LOCKING LID (APPROX) (APPROX) SDCB 12, TYPE 1 RIM 430.5' 12 IE 424.3 (IN-N)(OUT-S) SOLID LOCKING LID SDCB #I, TYPE 1 (EX) RIM 429.0' (COR) 12 /E 423.7 (COR) 12" 1E 423.7' (IN-N) EX. 12" SD 00.510.1 EXISTING GRADE-1FINISHED GRADE O 126 LF OF 12" PVC SD ® 0.5% 113 LF OF 1 " PVC D 0 O. ® 0.5 113 LF OF 12" PVC SD ° I ACCESS RISER, 5.5' 5.0' 1 4+ 00 I 1 3+ 00 12 + 00 THIS FACILITY IS SUBTERRANEAN AND N BE COVERED WITH GROUND COVER AND OTHER LANDSCAPING (PER PLAN) FINISHED GRADE = 432.0' \N \NY/ \ \NY/ w w j \N�� I I I I r ® 409 WRAP IN PERFORA TED (TYP) NON -WOVEN GOETEXTILE FABRIC (ALL SIDES), TYP STORM EXTENSION PLAN & PROFILE SCALE- 1 "=20' (PER PLAN) 0.5' MIN TOP OF RISER (12" DIA) 430.5' d (#2) 1 DETENTION TRENCH d a C3.0 SCALE- NTS 05/23/23 IE 428.5' i 2" IE 425.5' 423.5' REVISION 1.9' SURVEYED: DESIGNED: Sc. DRAWN: CC CHECKED: SC BY DATE APPR APPROVED: SC 1 1 +00 n �� ni inn 10+00 427.8' OEX. 8" SS lE 427.1' 2 STORM DRAIN INLET # 1 C3.0 SCALE- NTS SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M • CITY OF RENTON Planning/Building/Public Works Dept. c 0 10 20 HORIZONTAL SCALE 450 440 IIIII HORIZONTAL SCALE 430 420 ® STORM DRAINAGE CALLOUTS; 1. INSTALL STORM DRAIN CATCH BASIN TYPE 1, PER CITY OF RENTON STD. PLAN NO. 200.00, TYP (SEE DETAIL 1, SHEET C3.1). 2. INSTALL STORM DRAIN CATCH BASIN TYPE 2, PER CITY OF RENTON STD. PLAN NO. 201.00, TYP (SEE DETAIL 2, SHEET C3.1). J. INSTALL CONCRETE INLET, PER CITY OF RENTON STD. PLAN NO. 200.30, TYP (SEE DETAIL 3, SHEET C3.1). 4. INSTALL VANED GRATE, PER CITY OF RENTON STD. PLAN NO. 204.00, TYP. 5. INSTALL SOLID LOCKING LID, PER CITY OF RENTON STD. PLAN NO. 204.4 AND 204.5, TYP. 6. CONTRACTOR TO POTHOLE THE LOCATION AND DEPTH OF THE EXISTING SEWER STUBS. STORM DRAINAGE NOTES; 1. SURFACE WATER STANDARD PLAN NOTES, PER CITY OF RENTON STD. PLAN NO. 267.00 AND 267.10, TYP (SEE DETAIL 6 AND 7, SHEET C3.1). ®UTILITY ,CA LLOUTS; 1. FOR PROPOSED SANITARY SEWER DESIGN, SEE SHEET C4.0, TYP. 2 FOR PROPOSED WATER DESIGN, SEE SHEET C4.0, TYP. R-423407 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CURRENT PLANNINGIL SURFACE WATER UTILITY AWeihs 08/08/2023%.�#J Farah 08/11 /2023 :01 FNJand(ers MENT ENGINEERING 08/04/2023 :0] DATE: SHUM SHORT PLAT 05/23/23 CIVIL CONSTRUCTION PERMIT FIELDBOOK:___ PAGE: ___ DRAINAGE PLAN & PROFILE DRAWINC3.2 1157 QUEEN AVE NE, RENTON, WA. 98056 SHEET: 7 OF: 12 N N 0) O N N LJ O O N a J LO O O O O N N 1 co 6 0 W I— IC- G Z _O U rr Cn Z O U J U Q n I— rr O 2 C/) 75 2 C/) O r J PLANT SCHEDULE tty. Symbol 00 • 27 0 182 11 90 ,III 96 90 V'E 18 37 266 388 �l Botanical/ Common Name TREES: EXISTING TREE TO REMAIN :ISTING TREE TO BE REMOVED er g. 'Flame'/ AMUR MAPLE ignolia grandiflora Little Gem'/ EVERGREEN MAGNOLIA rrotia p. 'Vanessa'/ PERSIAN PARROTIA uja plicata 'Hogan'/ HOGAN WESTERN RED CEDAR Size/ Remarks min. 2" cal., single trunk min. 2" cal. min. 2" cal., single trunk min. 8'0" hgt. (4" cal.) HRUBS/ PERENNIALS/ GROUNDCOVERS: Cistus hybridus/ ROCKROSE min. 24" spr. Epimedium x versicolor 'Sulphureum' / NCN 1 gal. Myrica californica/ PACIFIC WAXLEAF MYRTLE min. 36" hgt. Pennisetum 'Hamlyn'/ DWARF FOUNTAIN GRASS 1 gal. Polystichum munitum / SWORD FERN min. 5 fronds @ 12" ea. Prunus I. 'Mt. Vernon'/ DWARF LAUREL min. 15" spr. Ribes s. 'King Ed. VII'/ FLWG. CURRANT min. 30" hgt. Vaccinium ovatum/ EVERGREEN HUCKLEBERRY min. 24" hgt. Arctostaphylos'Vancouver Jade'/ KINNICKINNICK 1 gal. @ 24" o.c., tri-spacing Mahonia repens/ CREEPING MAHONIA' 1 gal. @ 24 o.c., tri-spacing 'bold' * Plant sizes are specified per the American Standard for Nursery Stock, Publication - May 2, 1986 sponsored by the American Association of Nurserymen, Inc. * If plant quantity shown on schedule conflicts with what is represented by symbol on Plan, the quantity represented by symbol shall be used. SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT NW1/4. NE 1/4, SEC 09,T23 N.ROS E, W. M. \\ T-A/ \ .9DFIR s I � I\\ 21.9"DFlR� \ N / \ — T-46 \ 15.8"DFlR \ T-9 Existing Tree to 30.6 DFt .. (Remain (typ.) Y� / Existing Tree to \\\ \l\ \ Remain (typ.) Note: Keep all new planting a min. 8'-0" clr. REV-0- of trunk to minimize root 26.3 disturbance. \ .5",I ti T-12 I Al Existing Tree to Remain (typ.) I I T-C .1 "DFIR I 15'-0" 15'-0" 10'-0" — ti ti -titi - - ti ti ti ti ti ti ti ti ti� ti ti ti ti ti ti� Tree Protection Fencing (typ.) See \ `\` Civil Plans Sheet C2.0 i ° _ • LOT 'B' I I ` s�„ve T-1 MAD Perimeter of Infiltration a ° ° ; Trench I s t ° I I L � I ° 0� a vZ a' � � • ;Plant the row of groundcover a��V"`z ° • iadjacent to curb/ sidewalk ��lti • A8" clear of edge. l ti \�I/ tor ti ti ti ti titi ti ti ti ti ti ti` ti •. a c Plant the row of groundcover I l~ TRACTL n"• ad'acent to curb/ sidewalk ° 1 18" clear of edge. A z d I � O d I`rl I g, z • `' I� til tilt • a 5'-0" -,e— 8'-0" ° 4 `\` ` \ \ lam` ll • 4 44 I �- Tree Protection Fencing (typ.) See Civil Plans Sheet C2.0 SI v� ~`�111 /I\ / v \ Seeding Note: �l~l `� • \ d \I All areas outside of Building Setback \Line not planted as landscape beds til AE)l\ ° d ° shall be seeded a 'Low Grow' Erosion ° d ° Control Mix as approved. / o 0 = / ti ti ti ti • I `l~ll~l l~ll • • - 8 9"MAP \\lti\ti\ ~ l lti lti Existing Tree to \ \ Remain (typ.) / 0' 5' 10, 20' SCALE: 1" = 10'- 0" NORTH bill L - 23408 IN COMPLIANCE WITH CITY OF RENTON STANDARDS 10 X X X X X X X A, U T O 0 N N Q J O O N N I..L R CURRENT PLANNING o ,, AWeihs 08/08/2023 Q J Z W � �=�W 3 - Glenn Takagi � � Landscape Architect y�� 18550 Firlands Way N. ,r Suite#102 Shoreline, WA 98133 (206) 542-6100 glenco1029@earthlink.net SURVEYED SCALE VERMA1: NAVD 1 HORIZONTAL NAD 1983/199' DATUM • CITY O F � R E N TO N Planning/Building/Public Works Dept. S H U M SHORT PLAT CIVIL CONSTRUCTION PERMIT LANDSCAPE PLANTING PLAN 1157 QUEEN AVE NE RENTON , WA 98056 GT Dw► GT ONE INCH AT FULL SOME 9 ALNE�ACCCOORDNN�fiLY T N0. REVISION BY DATE APPR A APPROVED n �I rr DAM O 3/16/23 _ FlEUDOI C n PAGE: IMM1 O NO: L1.0 SNW. 10 OF 12 ( f co N O 0 LU rr LU IZ Z _O U D rr Cn Z O U J U Q J In rr O Cn 2 Cn O N J GENERAL NOTES: 1. Coordinate work with other trades as required. Determine location of underground utilities and perform work in a manner which will avoid possible damage. Coordinate with Utilities Underground Location Center and Owner for locations of existing underground utilities, etc. servicing or routed through the site. 2. Provide protection of all property, persons, work in progress, structures, utilities, walls, walks, curbs and paved surfaces from damages incurred arising from this work. The Contractor shall pay for any such damage at no additional cost to the Owner. 3. During construction, keep pavements, building clean. Protect site and adjacent properties from damage due to construction operations, operations by other Contractors/trades and trespassers. Unfinished and completed work shall be protected from damage by erosion or trespassing, and proper safeguards shall be erected to protect the Public. 4. Staking and Layout: Immediately notify Landscape Architect in writing of any variance between plans and actual site. Landscape Architect has the right to adjust the location of elements. Verify layout with Landscape Architect prior to any installation work. 5. Prior to beginning any construction, coordinate installation of Tree Protection Fencing and any Grading/ Soil Improvements with General Contractor, City and Owners Representative and Project A rhnrict 6. Verify installation conditions as satisfactory to receive work. Do not install any site elements until any unsatisfactory conditions are corrected. Beginning of work constitutes acceptance of conditions as satisfactory. When conditions detrimental to plant growth /constructed elements, are encountered such as rubble fill, adverse conditions, or obstructions, notify Landscape Architect. 7. New plantings shall be hand watered until established (generally 5 growing seasons) OR served by a Bidder Design Automatic Irrigation. Provide 20 gal. 'Slow Release Watering Bags' at each new tree planting if 'hand watering' option is selected. If Automatic System is selected, design and install per latest Irrigation Association Standards, 'WaterWise' Principles and local Codes/ Ordinances. Provide neat and legible color coded 'As Built' Plans to Owner prior to Project Completion. PLANTING NOTES: 1. Planting soil for new planting areas shall be a pre -approved approved Compost cultivated into the existing prepared subgrade. If existing subsoil is deemed not suitable by Landscape Architect, a pre -mixed soil with a 'Sandy Gravelly Loam' texture shall be used to achieve finish planting grades. Provide textural and nurtrient analysis of imported Sandy Gravelly Loam for approval. 2. Soil Preparation: Planting Beds: Determine/ attain shrub bed subgrade and cultivate to a minimum depth of eight inches (8"), clean/ remove all rocks, roots, debris over two inches in diameter. Lay a two inch (2") depth of Compost (or three (Y) depth of imported soil mix) over entire bed and till again to a minimum depth of six inches (6") to incorporate Compost thoroughly into grade. Then lay a two inch lift of Compost (or four (4") depth of imported soil mix) and till again. (total of 4" of added Compost or total of 7" of imported soil mix). Note that finish grade of mulched beds shall be one inch (1 ") below adjacent paved surfaces. NOTE: Do not use mechanical soil preparation techniques around Existing Trees to Remain; hand cultivating only to minimize root disturbance. 3. Fertilize all installed plants during backfill operations with 4-2-2 Agro Transplanter as recommended by Manufacturer. 4. Mulch all new ornamental beds and area within the Limit of Disturbance -Root Zone of Existing Trees to Remain with a minimum three inch (Y) depth of approved coarse shredded bark 'mulch' or Arborists Chips as approved. Finish grade of mulch shall be 1" below adjacent hard surfaces/ walls. 5. Stake trees per detail and as directed by Landscape Architect. 6. Maintenance: Provide landscape maintenance immediately after planting. Work to include but not limited to watering, pruning, resetting of plants, restoring eroded areas, adjustments to staking and removal of weeds/debris as required for healthy growth of plants. Maintain until Final Acceptance, but in no case less than 30 days. 7. The Landscape Architect retains the right to inspect trees, shrubs and groundcover for compliance with requirements for plant size and quality at any time. This includes but is not limited to size and condition of rootballs, root systems, insects, latent injuries and defects. Remove rejected material immediately from project site. 8. Upon completion, the Contractor shall request a 'Substantial Completion' of the installed work. Upon completion of the inspection, the Landscape Architect shall prepare a Contractor's list of items to be completed or corrected (Punch List) and indicate the time period for their completion or correction. If based on the opinion of the Landscape Architect the bulk of the work is acceptable, a Provisional Acceptance shall be granted. The Landscape Architect will make an inspection for Final Acceptance of the Work upon request by the Contractor. If all of the items of the Punch List have not been completed to the satisfaction of the Landscape Architect, additional inspections will be scheduled at the request of the Contractor. Final Acceptance shall not be granted until all of the items of the Punch List have been completed to the satisfaction of the Landscape Architect. At this time the Landscape Architect shall certify in writing the Final Acceptance of the Work. 9. Replacement of Plantings: Remove from site and replace with new planting, at Contractors expense, any plant that is either dead or in unsatisfactory condition, as determined by Landscape Architect as soon as conditions permit within normal planting season. All replacement plantings are then to be under reinstated guarantee period, as specified. Identify these replacements and take whatever necessary steps to prevent similar demise of plant materials. 10. Warranty: This Warranty shall include replacing and planting same size and species of plant material shown on Drawings that is designated to be replaced by the Landscape Architect. Except for loss due to excessively severe climatological conditions (20 year weather charts), installed plant materials are required to be guaranteed until the end of one growing season against defects and unsatisfactory growth, except for cases of neglect/abuse by Owners/others. All plants replaced shall be reinstated under plant guaranty conditions. SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT NW 1/4, NE 1/4,SEC 09,T23N, R05E,W.M. CHAINLOCK TIES MIN. 1.5 x 1.5 IN. APPROVED STAKE MATERIAL ALL STAKES SHALL BE DRIVEN OUTSIDE THE EDGE OF THE ROOT BALL. AMENDED BACKFILL 18"- DEEP ROOT BARRIER (PLASTIC, # AS REQUIRED (MIN. 4'0"). SET 1/2 BELOW GRADE ON SIDE TO BE PROTECTED. COMPACTED AMENDED BACKFILL. TAMP SOIL AROUND ROOT BALL BASE FIRMLY WITH FOOT PRESSURE SO THAT ROOT BALL DOES NOT SHIFT. i ° ° SECURE W/ LOOP OF CHAINLOCK. EACH TREE MUST BE PLANTED SUCH THAT THE TRUNK FLARE IS 2" ROUND PRESS. TREATED PINE POLE (OR APPROVED EQUAL) SET VISIBLE AT THE TOP OF THE ROOT BALL. TREES WHERE THE TRUNK TO LEE OF PREVAILING WINDS. FLARE IS NOT VISIBLE SHALL BE REJECTED. DO NOT COVER THE TOP OF THE ROOT BALL WITH SOIL. 4 IN. HIGH EARTH SAUCER BEYOND EDGE OF ROOTBALL. WOOD CHIP MULCH PER SPECIFICATIONS — ' 7--- l FINISH GRADE AMENDED BACKFILL FORM 6" HIGH J� PLANT PIT WITH ANGLED SIDES CONTINUOUS WATER BASIN ROOT BALL IF PLANT IS SHIPPED WITH A WIRE BASKET AROUND THE ROOT BALL, CUT THE WIRE BASKET IN FOUR PLACES AND FOLD DOWN 8 IN. INTO PLANTING HOLE. SET TOP OF ROOT 3 x dia. ► BALL FLUSH TO GRADE 1-2 IN. HIGHER IN SLOWLY DRAINING SOILS. TIGHTEN TIES ONLY ENOUGH TO KEEP FROM SLIPPING. ALLOW FOR SOME TRUNK MOVEMENT. CHAINLOCK SHALL BE LONG ENOUGH TO ACCOMMODATE 1.5 IN. OF GROWTH. DECIDUOUS TREE PLANTING NOT TO SCALE i B&B OR CONTAINERIZED SHRUB, TYP SET ALL PLANTS AT NURSERY LEVEL \ MIN 2"-3" OF MULCH (PER SPECS) SHRUB BED SOIL PREPARATION DEPTH (SEE SPECS) / ! FINISH GRADE DEPTH PER SPECS — �- REMOVE CONTAINER 7 COMPLETELY OR REMOVE ( BURLAP, WIRE & STRING FROM TOP 2/3 OF ROOTBALL NATIVE BACKFILL WITH SOIL AMENDMENTS - -- ---- (SEE SPECS.) UNDISTURBED SUBGRADE (PROVIDES FIRM BASE SO THAT ROOTBALL WILL NOT SINK) n,3 SHRUB PLANTING NOT TO SCALE 4 X O' S X 3 M Glenn Takagi o Landscape Architect Z 18550 Firlands Way N. Z Suite #102 Shoreline, WA 98133 (206) 542-6100 glenco1029@earthlink.net SURVEYED. SLUE SCALE ��CA r A ;��,�, DATUM �NM. T DRAWN: GT ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CHEMIMI GT NO. REVISION BY DATE APPR mmvED: APPROVED UNDISTURBED NATIVE -- SOIL OR COMPACTED SUBGRADE min. 3 x dia. No. CONIFEROUS TREE PLANTING NOT TO SCALE 4 GROUND COVER PLANTING NOT TO SCALE ADD JUTE FABRIC UNDERNEATH BARK MULCH ON SLOPES OVER 2:1 MIN 2"MULCH (PER SPECS) FINISH GRADE TYPICAL GROUND COVER 1 PLANTED AT NURSERY LEVEL l 1___SOIL AMENDMENT MIXED WITH NATIVE SOIL (SEE SPECS) SCARIFIED SUBGRADE R-423409 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CURRENT PLANNING AWeihs 08/08/2023 CITY OF SHUM SHORT PLAT DATE:3/16/23 =� CIVIL CONSTRUCTION PERMIT FIE�BDOK: RENTON LANDSCAPE NOTES &DETAILS DRAWING NO. Am Planning/Building/Public Works Dept. L2,0 1157 QUEEN AVE NE RENTON, WA 98056 sHor 11 OF 12 X X X X X X X � u (0 L0 O O O O N oC M 1 1 W C� G IZ W n Z _0 U IZ �I— U7 Z 0 U J U 1 n I— LL 0 VJ 2 U7 O co J J J J DEPARTMENT OF COMMUNITY CITY OF AND ECONOMIC DEVELOPMENT Renton 0 PARCEL'A'/ TRACT 'A' TREE RETENTION WORKSHEET Planning Division 1055 South Grady Way -Renton, WA 98057 Phone 425-430-7200 1 www rentonwa.gov 1. Total number of trees over 6" diameter', or alder or cottonwood trees at least 8" in diameter on project site 3 trees 2. Deductions: Certain trees are excluded from the retention calculation: Trees that are dangerous`' trees Trees in proposed public streets trees Trees in proposed private access easements/tracts trees Trees in critical areas and buffers trees Total number of excluded trees: 1 trees 3. Subtract line 2 from line 1: 2 trees 4. Next, to determine the number of trees that must be retained °, multiply line 3 by: 0.3 in zones RC, R-1, R-4, R-6 or R-8 0.2 in all other residential zones 0.1 in all commercial and industrial zones 1 trees 5. List the number of 6" in diameter, or alder or cottonwood trees over 8" in diameter that you are proposings to retain'': � trees 6. Subtract line 5 from line 4 for trees to be replaced: (if line 6 is zero or less, stop here. No replacement trees are required) 0 trees 7. Multiply line 6 by 12" for number of required replacement inches: o inches 8. Proposed size of trees to meet additional planting requirement: I'Minimum 2" caliper trees reauired for replacement, otherwise enter Ol inches per tree 9. Divide line 7 by line 8 for number of replacement trees6: (If remainder is .5 or greater, round up to the next whole number) 0 trees ' Measured at 4.S' above grade. A tree certified, In a written report, as dead, terminally diseased, damaged, or otherwise dangerous to persons or property by a licensed landscape architect, or certified arborlst, and approved by the City. Critical areas, such as wetlands, streams, floodplains and protected slopes, are defined in RMC 4-3-050. ` Count only those trees to be retained outside of critical areas and buffers, s The City may require modification of the tree retention plan to ensure retention of the maximum number of trees per RMC 4-4-1301-117a. ° When the required number of protected trees cannot be retained, replacement trees, with at least a two-inch (2') caliper or an evergreen at least six feet (6') tall, shall be planted- See RMC 4-4-130.H.1.e.(ii) for prohibited types of replacement trees. t H:\CED\Data\Forms•Templates\SeIf. Help Handouts\Planning\Tree Retention Worksheet.docx 08/2CI5 PLANT SCHEDULE Qty. Symbol Botanical/ Common Name Size/ Remarks Location TREES: EXISTING TREE TO REMAIN ]STING TREE TO BE REMOVED .er g. 'Flame'/ AMUR MAPLE uja plicata 'Hogan'/ HOGAN W R CEDAR agnolia grandiflora Little Gem'/ EVERGREEN MAGNOLIA 4 Parrotia p. 'Vanessa'/ PERSIAN PARROTIA min. 2" cal., single trunk Lots A and B min. 8'0" hgt. (4" cal.) Lots A and B min. 2" cal. Lots A and B min. 2" cal., single trunk Offsite TREE RETENTION/ REPLACEMENT PLAN NOTES: See Tree Assessment 1157 Queen Ave NE Renton, WA (Tree Report) prepared by Arbor Info LLC, 2406 N Castle Way Brier, WA for Tree Descriptions, Driplines, Assessment, Construction Impacts and other Site Tree information. PARCEL 'A': Replacement Inches Required- 0 TREE DENSITY NOTES: 2 Trees per 5,000 s.f. Required PARCEL 'A' + TRACT 'A': 14,560 s.f. (/) 5,000 (x) 2 = 6 Trees Required 12 Trees Provided (11- new + 1- Existing Maple) Glenn Takagi 1V Z Landscape Architect a00 6 ~ Z 18550 Firlands Way N. m Z Suite #102 gLII) 3 a Shoreline, WA 98133 Q " (206)542-6100 glencol 029@earthlink.net SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT NW1/4.NE 1/4, SEC 09,T23 N.ROS E. W. M. 0 T-13 Rej -C 0.1"DFIR I y T-A \ I G O \ \.- 21.9"DFIR - — —\ - - - - - - - - - - - -i \ yl T_-10 _K15.8"DFIR \ Tree Protection — — — \ \ / a Fencing -- — —— �— — — — — — — — — 10 \ / I / T-9 30.6 DFIR a ° d + / LOT B II Tree 'Dripline' I C �/ I d T-1 T— '(typ•) 51.;"MAD I 12. "sM0 ( -- — / ExistingTree to Existing Tree to be r Remain (typ.) t \ Removed (typ.) I R 26. I \ 26.3"DFIR d \ d` \ L/ 30.5"DFIR a / — — °.° Existing Tree to be a T-a2 ° Removed (typ.) — f-- --T-- ° 3"DFIR14 ° ° d d d \d T-6 3a 1.8"DFIR LOT W .fi Tree, Dripline (typ.) T-5 / 3E25.3"DFIR Q *29.5"Dlr/ I d REVISION R I \ I I I \ I I \ Tree 'Dripline' (typ.) " / Tree Protection / Fencing I Existing Tree to Remain (typ.) / SURVEYED DESIGNED GT DRAW GT CHECKED; GT BY DATE APPR AFC: APPROVED 0' 5' 10, 20' SCALE: 1" = 10'- 0" FIORIZONT�AL tI D 198 IO/1/1991 1 "= 10'-0" ONE INCH DATU M AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY NORTH CITY OF RENTON Planning/Building/Public Works Dept. !'TRACT A �n v R-42341 0 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CURRENT PLANNING o AWeihs 08/08/2023 SHUM SHORT PLAT 3/ 16/23 CIVIL CONSTRUCTION PERMIT �0ft PAGi TREE RETENTION/ REPLACEMENT PLAN DDPAW MW. L3.0 1157 QUEEN AVE NE RENTON, WA 98056 giEET 12 OF 12 X X X X X X X , U T 0 O N N Q J L0 O O N �N• LL I- J �I 0 U'7 U'7