NOTES:
H
1.
FIRE HYDRANT TO BE PAINTED WITH TWO COATS OF SAFETY YELLOW DTM ACRYLIC GLOSS OR ENAMEL PAINT.
2,
PUMPER NOZZLE TO FACE ROADWAY OR AS DIRECTED BY RRFA.
3.
A MINIMUM T RADIUS
UNOBSTRUCTED WORKING AREA SHALL BE PROVIDED AROUND THE OUTSIDE OF THE HYDRANT.
MATERIALS
COMPRESSION TYPE HYDRANT (SEE APPROVED MATERIALS LIST) WITH 6" MJ INLET WITH LUGS, 5 X" MVO,
OA
HYDRANT
1 A" PENTAGON OPERATING NUT, TWO (2) 2 )2" NST HOSE NOZZLES, AND 4.875" SST PUMPER NOZZLE
EQUIPPED WITH 5" STORZ ADAPTER AND 1/8" STAINLESS STEEL CABLE, WITH EXTENSION IF NECESSARY.
O
TEE
MAIN LINE TEE WITH 6" FLANGE SIDE OUTLET
OC
VALVE
6" GATE VALVE (FLxMJ)
O
VALVE BOX
VALVE BOX AND LID PER STD PLAN 330.7
OE
PIPE
CLASS 52 DI, LENGTH TO FIT
O
JOINT RESTRAINT
MECHANICAL JOINT RESTRAINT OR (2) 3/4" CORTEN STEEL TIE RODS FOR DISTANCES OVER ONE PIPE LENGTH
O
GRAVEL
1 X" WASHED DRAIN ROCK, MINIMUM V ABOVE BOOT FLANGE WITH 8-MIL POLYETHYLENE SHEETING
AROUND TOP AND SIDES OF GRAVEL
O
CONCRETE BLOCK
MINIMUM 16"x8"x4" CONCRETE BLOCKS UNDER FIRE HYDRANT AND GATE VALVE
O
BLOCKING
CONCRETE BLOCKING PER STD PLAN 330.1
4'x4'x6" CONCRETE SHEAR BLOCK AROUND FIRE HYDRANT WITH EXPANSION JOINT AT BACK OF SIDEWALK,
O
SHEAR BLOCK
FINISH TO MATCH SIDEWALK, ALL CONCRETE SHALL BE MINIMUM 3,000 PSI AND SHALL BE MECHANICALLY
MIXED - JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT ALLOWED.
OK
PAVEMENT MARKER
BLUE REFLECTIVE PAVEMENT MARKER PER STD PLAN 310.3
STD. PLAN - 310.1
4A PUBLIC WORKS
FIRE HYDRANT ASSEMBLY
APPiO',E'l
DEPARTMENT
SHUM SHORT PLAT - CIVIL CONSTRUCTION PERMIT
NW 1/4 NE 1/4, SEC 09, T 23 N, R 05 E. W. M.
�I INUNIMPROVED ROW,
�I
w • INSTALL METER BOX w • CITY I PRIVATE
p• AT PROPERTY LINE WITH p• ��
a 1" COPPER TAILPIECE a I PIPINGI PIPING
I
I
p E SIDEWALK
FINISHED GRADE 9" TO 12"
24" TO 30" I 21" TO 30'
22 3/2' -cLa
MAIN 8 C
V
LOOP DOWN TO CENTERLINE OF WATER MAIN
TO PROVIDE SLACK IN SERVICE LINE TO METER
MATERIALS
O CORPORATION STOP 1" BALL CORPORATION STOP WITH BALL VALVE, AWWA TAPERED THREAD (CC) INLET, QUICK JOINT OUTLET,
FORD FB1000-4•Q-NL OR A.Y. MCDONALD 74701BQ
OB TUBING 1" TYPE "K" SOFT COPPER TUBING
1" SETTER, QUICK JOINT INLET AND OUTLET, PADLOCK WINGS ON INLET ANGLE BALL VALVE, SINGLE CHECK
O METER SETTER VALVE ON OUTLET, FORD VBH74-15W-44.44-Q-NL, A.Y. MCDONALD 721.415WCQQ44, OR MUELLER
B-24701-6AN, INSTALL CENTERED AND SQUARED IN METER BOX, PROVIDE ADAPTERS FOR 5/8"x3/4" METERS
OD WATER METER AMI WATER METER WITH RADIO AND BATTERY UNIT, TO BE PROVIDED BYTHE CITY
O METER BOX METER BOX, ARMORCASTA6001946PCX18, WITH METER BOX LID, ARMORCASTA6001969RC1-H7, TO READ
"RENTON WATER"
O COUPLER AND PLUG COUPLER (PACK JOINT x PACK JOINT), FORD C4#4#-Q-NL, WITH 1" GALVANIZED PLUG IF SERVICE LINF TO
PROPERTY IS TO BE INSTALLED IN THE FUTURE
GO GRAVEL 1 X" WASHED GRAVEL
nPPaovEo STD. PLAN - 320.1
• PUBLIC WORKS
DEPARTMENT 1'I WATER SERVICE
DA�i
MINIMUM BEARING AREA
AGAINST UNDISTURBED SOIL (SF) "
90' BEND 45P BEND
A C
i-
CAP / PLUG 22 Y2P BEND
B DIS13
TEE 111/4P BEND • VALUES BASED ON SAFE BEARING LOAD OF 2,000/(3,000) PSF
Cr-- B P .� E SOIL TYPE SAFE BEARING LOAD (PSF)
MUCK OR PEAT 0
SOFT CLAY 1,000
SAND 2,000
SAND AND GRAVEL 3,000
CEMENTED WITH CLAY 4,000
HARD SHALE 10,ODO
NOTES:
1. MINIMUM BEARING AREA MUST BE ADJUSTED FOR PIPE SIZE, PRESSURE, AND SOIL CONDITIONS.
2. FITTINGS SHALL BE POLYWRAPPED PRIOR TO POURING CONCRETE BLOCKING.
3. CONCRETE BLOCKING SHALL BE CAST IN PLACE AND SHALL HAVE A MINIMUM OF 0.25 SF BEARING AREA AGAINST THE FITTING.
4. CONCRETE BLOCKING SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE CLEAR OF JOINTS TO PERMIT TAKING UP OR DISMANTLING
JOINT.
S. CONTRACTOR SHALL INSTALL BLOCKING ADEQUATE TO WITHSTAND FULL HYDROSTATIC TEST PRESSURE AS WELL AS TO CONTINUOUSLY
WITHSTAND OPERATING PRESSURE UNDER ALL CONDITIONS OF SERVICE.
6. ALL CONCRETE SHALL BE MECHANICALLY MIXED. JOB SITE MIXING, HAND -MIXED CONCRETE, AND MOBILE CONCRETE MIXERS ARE NOT
ALLOWED.
7. IN MUCK OR PEAT, ALL THRUSTS SHALL BE RESTRAINED BY PILES OR TIE R005 TO SOLID FOUNDATION OR MUCK OR PEAT SHALL BE
REMOVED AND REPLACED WITH BALLAST OF SUFFICIENT STABILITY TO RESIST THRUST.
8. CONCRETE BLOCKING SHALL BE LEFT OPEN OR SHEETED FOR MINIMUM 24 HOURS.
:.rvsov6o STD. PLAN - 330.1
• PUBLIC WORKS CONCRETE BLOCKING
�� DEPARTMENT FOR HORIZONTAL FITTINGS
DocuSlgn Envelope ID 345B681D-914F-4F2D-AB59-7C192D3B78A3
r-1----------
I— EX. SEWER MAIN
r
i I
PROPERTY LINE
—SPOOL
i
z
(LENGTH AS NEEDED) ( 1
1 }'-0'
MIN
5" SEWER STUB
I I I
I M H
O I
I
FUTURE 4' SIDE SEWER
I I I
2"x 4" STUD MARKING POST PAINTED
6' CAP J WHITE WITH THE WORD 'SEWER' STENCILED
SEWER MAIN TEE X 6"
TEE i i i
i I
IN 3" HIGH BLACK LETTE45 AND /6 ORE
I i
SIDEWALK l i
WRAPPED AROUND THE STUD AND
COUPLING (TYP)
1
IL
L_J_L_________J
<
EXTENDED TO THE TOP OF THE STUD
t>1
6"X5'%6' SURFACE CLEANOUT WITH CAST IRON RING AND COVER
(EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR
(4
APPROVED EQUAL. SPECIFY "SEWER- ON UD),
I m
CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD
CONCRETE PAD TO BE 8' IN DEPTH
r
"---,
--
BEND AS g"
REQUIRED
EXISTING SAW iARY
SEWER MAIN —2-OX MIN SLOP£ `
`FUTURE 4" SIDE SEWER
1 �6" SEWER 57uB 6"x6'%6" WYE FUTURE fi"x i' REDUCER
\\SEWER MAIN SIZE X 6" TEE
ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTUMS TO E70S M SEWER KAII
A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK' FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL).
B CONCRETE MAIN - CUT IN A NEW PVC 'TEE' USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL)
C PVC & C900 PVC MAIN - CUT IN NEW TEE USING RICID COUPLINGS OR CORE --DRILLED ON A ROMAC SADDLE
(OR APPROVED EQUAL)
D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL)
E LINED MAIN - CONNECTION TO SEWER MAINS THAI HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING
'STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL),
F HOPE - CORE -DRILLED WITH A ROMAC SADDLE 'INSERTA-TEE- MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER
C MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE
SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL
tI NOTES
TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM ME CITY OF
RENTON PUBLIC WORKS DEPARTMENT
2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER
3 SIDE SEWERS SHALL HAVE A MINIMUM 2 X SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR
4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SDE
SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT
THE APPOINTED TIME 00 NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR
5 ALL TRENCH RESTORATION FOR S1DE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102
6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405
7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON
WORKS
SIDE SEWER STUB P ySTD. PLAN -406.1
PUBUIC DEPARTMENT INSTALLATION AMartin PaStUChW26/202
(SEWER MAIN TO PROPERTY LINE)DAR
Sll•LT3101Ad'J
1 3 1 O, 1 2 320, 1 3 330, 1 4 406. 1
C4" 0 SCALE- NTS C4. 0 SCALE. NTS C - 0 SCALE. NTS , SCALE. NTS
DocuSlgn Envelope ID 345B681D-914F-4F2D-AB59-7CT92D3B78A3
ALL 90 TURNS SMALL BE ACCOMPLISHED
4" BEND AS REWIRED (NO GREATER
BY MEANS OF A WYE OM CLEANOUT AND
45 BEND TWO 45' BENDS SHALL NOT BE
THAN 45' BEND) EVERY 2ND CHANCE
4" CLEANOUT WYE ON
ACCEPTABLE (SEE NOTE It)
IN DIRECTION DR GRADE WILL REQUIRE
45 BEND AND PLUG
A CLFANOUT WYE (SEE NOTE 11)
I (SEE NOTE II)
HOUSE
I
HOUSE
gl
HOUSE
EI
HOSE
3
-0" MIN
4" SEWER PIPE
SURFACE CLEANOUT
CE6".
6"x6"WYE
(SEE STO PLAN - 407)
4" TEST TEE VAN
4" SEWER PIPE. SEE NOTES 2
AND 3 MINIMUM LINE SIZE FOR
VjC;LESAu11W.
PLUG FACE UP
OTHER THAN SINGLE FAMILY IS 6"
R 0 W LINE
(TYPICAL) I,
R 0 W TINE
3' MIN
6"x 4" REDUCER
(TYPICAL).
NOTES
IF THE BUILDING SEWER SERVES ANY FIXTURE HAVING
FLOW LEVEL RIMS LOCATED BELOW THE ELEVATION
I PRIOR TO INSTALLATION Of A SANITARY SEWER CONNECTION.
g OF THE NEXT UPSTREAM MANHOLE COVER OF THE
SIDE -SEWER PERMIT MUST BE PURCHASED FROM THE CITY Or
PUBLIC SEWER SYSTEM. A BACKFLOW PREVENDON
RENTON PUBLIC WORKS DEPARTMENT
c 3 DEVICE SUCH AS CLEAN CHECK EXTENDABLE
BACKWATER VALVE OR APPROVED EQUAL SHALL BE
m INSTALLED
2 FOR INSPECTION OF SDE SEWER, CALL 24 HORS IN ADVANCE
THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER PERMIT
4" FLEXIBLE COUPLING (FERNCO OR EQUAL)
'}� ¢
SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE
ON SITE WEN INSPECTOR ARRIVES AT APPOINTED TIME DO NOT
9 I}'
BACKFTLL THE OITCI- UNTIL APPROVAL IS GIVEN BY THE INSPECTOR
r, I� SURFACE CLEANOUT
r3 4'•• 4"•4" WYE
3 SIDE SEWER PIPE AND FITTINGS SHALL BE PVC SDR 35 NTH RUBBER
4" PIPING
GASKET JOINTS UNLESS OTHERWISE APPROVED BY THE PUBLIC
PLAN
WORKS DEPARTMENT
BUILDING DRAIN FOR
LOW ELEVA DONHOUSE
4 A MINIMUM GRADE OF 2X (1/4" PER FOOT) MUST BE MAUNTAINEO
WITH A 4" PIPE IN ME EVENT A 2X GRADE CANNOT BE MAINTAINED
ON TIRE APPROVAL OF THE PUBLIC WORKS INSPECTOR, THE
MAIN TO S FEET
CONTRACTOR MAY INSTALL A 6' DIAMETER SIDE SEWER AT NO LESS
R O W LINE R O W, LINE TO CLEANOUT AX
THAN 1X
90E SEWER BUILDING SEWER BUILDING
STUB DRAIN
5 INSTALL SDE SEWER OTH 2' MINIMUM COVER 13" COVER IS ALLOWED
S FEET MIN I—
AT THE MOUSE IF OUTLET IS SHALLOW
�Lrr�
6 All BUILDING SEWER AND 510E SEWERS SHALL NAVE REDOING IN
�I I
ACCORDANCE HIM STANDARD PLAN tD5
n j +
7 WHENEVER FEASIBLE. THERE SHALL BE A MINIMUM 5 FOOT
z� '�
c
HORIZONTAL SEPARATION BETWEEN SANITARY SIDE SEWERS AND ALL
VIo8 >e>i>
y"• OH;r� S
OTHER UTILITIES
�� z
'R, ♦ O z S
r g n,, IA
8 SIDE SEWER TESTING SHALL CONSIST OF PLACING A PLUG IN THE
n u fP Tz
z o £
TEST TEE AND INSTALLING A 4-FOOT RISER PIPE ON THE CLEANOUT
a g c- g
n
AT ME BUIDINC. THE SIDE SEWER PIPE SMALL BE FILLED TO WITH
♦ i .r.
&- n
WATER TO ME TOP OF THE RISER PIPE NO LOSS OF WATER SHALL
OCCUR FOR A PERIOD O 10 MINUTES. THE SIDE SEWER MAY BE
r�•
,..• z
CONNECTED TO THE BUILDING FOLLOWNG THE SUCCESSFUL
o P,
COMPLETION OF ME LEAK TEST
'a v
9 THE CLEANOUT AT THE RIGHT-OF-WAY SHALL BE INSTALLED PER
P AN
STANDARD PLAN 4061 THE CLEANOUT AT THE BUILDING SHALL BE
BINSTAL SEWER
INSTALLED TO SURFACE GRADE ALL OTHER CLEANOUFS SHALL BE
WLOING TION
INSTALLED TO WITHIN 12' OF THE SURFACE
10 IF SIDE SEWER STUB IS NOT AVAILABLE THE OWNER SHALL BE
RESPONSIBLE FOR ITS INS7ALLAnON PER STANDARD PLAN 4061
ALL WORK "THIN STREET RIGHT-OF-WAY SHALL BE DONE BY A
LICENSED AND BONOED CONTRACTOR
CALL 811 BEFORE YOU DIG
11 AL- TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC
or go CO
RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102
www co9oeforeyoua g org
12 ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE W tH THE
WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACT (OSHA)
TYPICAL BUILDING SEWER
STD. PLAN -406,2
PUBLIC WORKS
APPp�
DEPARTMENT
FROM PROPERTY
LINE TO
Martin PastUCHjV26/202
BUILDING CONNECTION
—�ww�006 90 MR
5 406,2
C - 0 SCALE. NTS
1 12:
05/23/23
Rol
REVISION
BY I DATE
SURVEYED:
DESIGNED:
DRAWN: SC
CC
CHECKED:
SC
A P P R APPROVED:
SC
SCALE:
NTS
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
IL
I
1 12:
W-423402 S-423402
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
IN
DEVELOPMENT ENGINEERING
•
NJanders 08/04/2023
DATE:
VERTICAL: NAVD 1988 • SHUM SHORT PLAT
HORIZONTAL: NAD 1983/1991 CITY OF 05/23/23
RENTON CIVIL CONSTRUCTION PERMIT FIELDBOOK:===
PAGE:
•
DATUM DRAWING N0:
Planning/Building/Public Works Dept. UTILITY DETAILS C4. 1
1157 QUEEN AVE NE, RENTON, WA. 98056 SHEET: 9 OF: 12