HomeMy WebLinkAboutNE 12th St Townhomes_Pre-App-Map-Site PlanNE 12TH ST
30
.
0
0
'
134'
124'
10'
30
2
'
18
7
'
11
5
'
PROPOSED
4-PLEX
(BLDG A)
15
.
0
0
'
10.00'
40.67'
40.00'
21.38'
10
.
0
0
'
10.00'
20.00'
28.50'
COMMON OPEN
SPACE
PROPOSED
4-PLEX
(BLDG B)
PROPOSED
4-PLEX
(BLDG C)
PROPOSED
DRIVE AISLE
PROPOSED
DRIVE AISLE
(R
O
W
)
5.00'
5.00'
8' PLANTING STRIP
5' SIDEWALK
13
.
0
0
'
16
.
5
4
'
10
0
.
0
0
'
33
.
3
6
'
27
.
4
6
'
10
.
0
1
'
10.06'27.46'28.99'27.46'39.95'
10.00'100.00'23.90'
14
.
6
7
'
27
.
4
6
'
31
.
3
7
'
10
0
.
0
0
'
15
.
0
0
'
6" CURB/GUTTER
TREE #1, 26" LOMBARDY
POPLAR (POPLULUS
NIGRA 'ITALICA') OFF SITE
TREE #2, 14" COLORADO
BLUE SPRUCE (PICEA
PUNGENS GLAUCA) TO
BE REMOVED
TREE #3, 24" COLORADO
BLUE SPRUCE (PICEA
PUNGENS GLAUCA) TO
BE REMOVED
TREE #4, 14" PONDEROSA
PINE (PINUS PONDEROSA)
TO BE REMOVED
TREE #5, 54" DOUGLAS
FIR (PSEUDOTSUGA
MENZIESII) TO REMAIN
TREE #9, 10" MOUNTAIN
ASH (SORBUS AUCUPARIA)
TO REMAIN
TREE #10, 52" DOUGLAS
FIR (PSEUDOTSUGA
MENZIESII) TO REMAIN
TREE #11, DEAD TREE
TO BE REMOVED
TREE #6, 16" APPLE
(MALUS DOMESTICA)
TO BE REMOVEDTREE #7, 12" APPLE
(MALUS DOMESTICA)
TO BE REMOVED
TREE #8, 12" MOUNTAIN
ASH (SORBUS AUCUPARIA)
TO BE REMOVED
TREE #12, 24" LOMBARDY
POPLAR (POPLULUS
NIGRA 'ITALICA') TO BE
REMOVED
Renton, WA 98057
425-271-0082 (office)
P.O. Box 476
Project No:
Drawn By:
Date:
WRITTEN DIMENSIONS ON THESE
DRAWINGS SHALL HAVE PRECEDENCE
OVER SCALED DIMENSIONS. CONTRACTOR
SHALL VERIFY ALL DIMENSIONS AND SITE
CONDITIONS FOR THIS PROJECT, PRIOR TO
THE CONSTRUCTION PHASE. IT IS THE
CONTRACTORS RESPONSIBILITY TO
REPORT ANY/ALL DISCREPANCIES TO THE
DESIGNER AT THE TIME THEY ARE
IDENTIFIED.
CW DESIGN, INC MUST BE NOTIFIED OF ANY
VARIATIONS FROM THE DIMENSIONS
AND/OR CONDITIONS SHOWN ON THESE
DRAWINGS. ANY SUCH VARIATIONS SHALL
BE RESOLVED PRIOR TO PROCEEDING WITH
ANY WORK, OR THE CONTRACTOR SHALL
ACCEPT FULL RESPONSIBILITY FOR COST
TO RECTIFY SAME. IN THE EVENT ANY
LIABILITY IS IMPOSED ON CW DESIGN, INC,
OUR LIABILITY TO YOU AND/OR ANY THIRD
PARTY SHALL NOT EXCEED THE FEE PAID
TO CW DESIGN, INC, FOR THE DRAWINGS
PRODUCED FOR THIS PROJECT. ANY
UNAUTHORIZED ALTERATIONS OF THESE
DRAWINGS BY THE CONTRACTOR AND/OR
THIRD PARTY, SHALL HOLD CW DESIGN, INC.
HARMLESS FROM ANY CLAIMS ARISING
FROM UNAUTHORIZED ALTERATIONS.
Copyright 2025
CW Design, IncC
Status:
Scale:
Sheet Name:
No.Remarks Date
-Submittal Set
nc.CW Design,I
WJB
1
2
3
4
5
6
7
8
9
NE
1
2
t
h
S
t
T
o
w
n
h
o
m
e
s
34
0
1
N
E
1
2
t
h
S
t
Re
n
t
o
n
,
W
A
25039
Aug 19, 2025
Review Set
xx/xx/23
--
--
--
--
--
--
--
--
--
1 of 1
Preliminary
Site Plan
1" = 20'-0"
SITE DATA
PARCEL NO:092305-9124
LEGAL DESC:W 34 FT OF E 269 FT OF N 5 AC OF W 1/2
OF NW 1/4 OF NE 1/4 LESS S 115 FT OF E
124 FT LESS CO RD LESS C/M RGTS SUBJ
TO ESMT TRANS LN
SITE AREA:26,140 SF (0.60 ACRES)
SCOPE OF CONSTRUCT (3) NEW 4-PLEX TOWNHOUSE
WORK:BUILDINGS. EACH UNIT TO HAVE A 2-CAR
GARAGE.
ZONING:RM-F & URBAN DESIGN DISTRICT B
REQ'D FRONT YARD - 15'
REQ'D SIDE YARD - 5'
REQ'D REAR YARD - 10'
MAX WALL PL HEIGHT - 32' ABV AVG GRD
MAX ROOF HEIGHT - ADDITIONAL 6' ABV
MAX WALL PL HEIGHT IF ROOF
SLOPES AT 4:12 OR GREATER
BUILDING COVERAGE
BUILDING FOOTPRINT, BLDG A): 2,886.84 SF
BUILDING FOOTPRINT, BLDG B): 2,886.84 SF
BUILDING FOOTPRINT, BLDG C): 2,886.84 SF
TOTAL BLDG COV AREA: 8,660.52 SF
(33.13%)
ALLOWABLE BLDG COV:18,298.00 SF
(70.00%)
Site Plan
20'
1"=20'
40'10'0'
N
IMPERVIOUS COVERAGE
ROOF AREA, BLDG A): 3,213.70 SF
ROOF AREA, BLDG B): 3,213.70 SF
ROOF AREA, BLDG C): 3,213.70 SF
DRIVE AISLE PAVING 6,030.23 SF
TOTAL IMP COV AREA:15,671.33 SF
(59.95%)
ALLOWABLE IMP COV:19,605.00 SF
(75.00%)
Vicinity Map
NOT TO SCALE
N
SITE
LOCATION
Project Narrative – NE 12th St Townhomes
Site Address – 3401 NE 12th St, Renton WA 98056
Parcel No – 0923059124
Applicant – CW Design, Inc / 425-271-0082 / PO Box 476, Renton WA 98057
The subject parcel currently has a one-story single-family dwelling (approx. 990sf) constructed in
1938. Based on city GIS mapping there are no critical areas within the subject parcel. The subject
parcel is 26,140 square feet (0.60 acres), based on King County Assessor’s data.
The proposed townhouse development will consist of (3) separate 3-story buildings, each
building will have 4 dwelling units with attached garages. Each dwelling will have an entry
accessed from the on-site paved drive aisle. Access to the subject parcel will be taken from NE
12th St.
The subject parcel is zoned RMF, which allows for a minimum net density of 10 dwelling units
per acre up to a maximum net density of 20 dwelling units per acre. The proposed development
will have 12 total dwelling units (0.60 acres x 10 = 6 min dwelling units and 0.60 acres x 20 = 12
max dwelling units).
The subject parcel has 11 existing trees on site. The proposed development will retain 3 of the
existing trees (trees 5, 9, and 10). Tree #11 was determined to be a dead tree and will be
removed. The trees to be removed for the proposed development are 1, 2, 3, 4, 6, 7, and 8.
Pre-App Questions
1. Based on retaining three of the existing trees, will additional replacement trees be
required due to the trees being removed for development?
2. We are proposing a paved 20ft access to the site. Does this meet the current fire access
requirements? Is a fire apparatus turn-around required?
3. If the buildings are sprinkled, can we reduce the rated wall assembly requirements?
4. If we provide two parking spaces within each unit garage, are we required to add any
surface parking for guests?
5. What are the required frontage improvements along NE 12th St?
6. Are there any minimum common area/amenity area measurements (i.e. 20ft in any one
direction)?
7. Can we place the stormwater facility under the proposed drive aisle?
8. Is there a ROW dedication required?
9. Are affordable units required for a 12-unit development?
10. Is SEPA required?
11. Do we need to submit for a civil permit prior to the building permits, or can they run
concurrently?