Loading...
HomeMy WebLinkAboutPN_Project Narrative_180516-Final.pdfINNOVA Architects Inc. (253) 572-4903 950 Pacific Avenue, Suite 450 Tacoma, WA 98402 Page 1 of 2 PROJECT NARRATIVE May 16, 2018 Planning Division City of Renton 1055 South Grady Way Renton, WA 98057 Project Name: 601 Monster Road SW Building and Site Redevelopment Land Use Permits Required: SEPA, demolition permit, NPDES, SWPPP Zoning Designation: Industrial Medium (IM), adjacent properties are like zoning and use. Property to the east, opposite side of right-of-way is Industrial Heavy. Current Use of Site and Existing Improvements: The site is a 9.61 acre industrial parcel (242304-9008) located at 601 Monster Road SW. The existing concrete tilt-up warehouse building was most recently used by Graphic Packaging and has a 143,862 SF footprint with a small portion of this being a single story office. To the south of the main building is a small shop facility building. The developed portions of the site are generally flat and allowed for the maneuverability of large semi- trucks. There is a portion of the site used for vehicle parking near the southeast corner of the building that is slightly elevated. Beyond the southern development limits of the site the grades climb upwards toward the adjacent parcel. The existing stormwater collection system collects stormwater around the site and discharges it off this site at three locations. The existing north parking area directs flows directly to Monster Road SW with no on-site collection facility. There is one catch basin at the northeast corner of the site that picks up a small amount of flow and directs it to the existing conveyance system along Monster Road SW on the east side of the site. The rest of the impervious surfaces, parking, driveways and the roof area are collected in a conveyance system that first flows south then west along the south side of the site and on to an existing off-site conveyance system. This system along with the other two noted above are directed to an existing stormwater “Regional Detention Facility Pump Station” system created in 1995 about 200 feet west of this site. The existing building is connected to the City of Renton’s sanitary sewer system at the northeast corner of the building. There is an existing 8” and 3” service lines that drains to an existing sanitary sewer manhole at this location. The 8” sewer line continues north to the main trunk line which runs west to east along Monster Road SW. This line continues to the regional sanitary sewer plant just east of this site. INNOVA Architects Inc. (253) 572-4903 950 Pacific Avenue, Suite 450 Tacoma, WA 98402 Page 2 of 2 There is an existing domestic water service and fire lines to this building are along the north side of the building and come from the City of Renton’s water mains that run along Monster Road SW. Special Site Features: A majority of the site is relatively flat but sits lower than the adjacent south parcel and right-of-way to the east. Adjacent property grades fall onto the project site from slight slopes to as great as 40%. No development is proposed within these steep slope areas. Statement addressing Soil Type and Drainage Conditions: Test pit data has been provided as part of the soils investigation developed by Terra Associates Inc. It identifies site soils for most of the site as fill material, averaging about 5 feet deep; underlain by soft to dense interbedded alluvial soils. Proposed Use of the Property and Scope of the Proposed Development: The immediate proposed effort is demolition of the existing 143,862 SF concrete building and the detached 2,900 SF shop building. Demolition efforts include capping of existing utilities, Future redevelopment of the site is currently under land-use review. For Plats Indicate the Proposed Number, Density and Range of Sizes of New Lots: Not Applicable. Access: Existing-The site is currently served by four points of access. One drive serves the existing east parking and truck service areas at Monster Road accessed by SW. A second drive (of two driveways) serves the north parking area at the existing office area. The last point of access is from a private drive along the west face of the building which connects to a south drive lane along the existing building. Proposed- The demolition efforts will utilize the existing driveways. Proposed Off-site Improvements: None, this proposal for building demolition effort only. Total Estimated Construction Cost and Estimate Fair Market Value: Estimated project costs are currently approximated to be $373,750 limited to demolition efforts only. Estimated Quantities and Type of Materials Involved if any Fill or Excavation is Proposed: None Number, Type and Size of any Trees to be Removed: None Explanation of any Land to be Dedicated to the City: None Any Proposed Job Shacks, Sales Trailers and/or Model Homes: The general contractor for the project may establish a temporary work trailer office. Any Proposed Modifications Being Requested: None