FOOTINGt�` �
ED F PR P �IGHTPOLEA; TYP REFER T
Q L C AND STRUCT PLAN
d.
a 1
PCAB ° ' L`J'
R -- � � 1 I �.: a
P C AB B �D WORLD CUP LEGACY POP LIGHTING RO T N a. >
SQUARE PROJECT (2)-1" PVC 01 I S
(E31�' THEIRS) EFER TO ELEC PLAN Z
RM CAG-25-044 I 1 Q
0
1 0
o
P �
BLDR I
PROP LIGHTING POC 3 METAL HA 4'.0'
COORDINATE WITH WORLD CUP IGHT POLE ,dC,TYP ° --
SQUARE PROJECT FOR ROUTING �-RfFER TO ELELANS .
TO SERVICE CABINET (2)-3/4" PVC I
CONDUITS REFER TO ELEC PLANS � -
a .a
SD
SD
P I -
RIGHT-OF-WAY LINE, TYP
1
LIMITS OF WORK, TYP MATCH EXIST GRADES AT
EXIST PAVEMENT AND
RESTORE PAVEMENT TO
NEAREST JOINT LINE, TYP
W W W W
S 3RD ST
1601 5th Avenue, Suite 1600
Seattle, WA 98101
206.622.5822
www.kpff.com
• Call 811
• a two business days
before you dig
N0.
REVISION
0
c`M
CU
H
w
w
U)
0
w
LL
LLJ
OC
LLJ
Z_
J
F_
BY I DATE
SURVEYED:
DESIGNED:
DRAWN:
CHECKED:
AP P R I APPROVED
SCALE:
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
NOTES:
1. REFER TO C1.00 TO C1.02 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.
REFER TO C3.00 FOR CIVIL IMPROVEMENT'S LEGEND AND NOTES.
2. CONTRACTOR SHALL CONFIRM POC'S PRIOR TO CONSTRUCTION WHEN CONNECTING TO EXISTING
SYSTEMS AND NOTIFY ENGINEER OF ANY DISCREPANCIES. PRIOR TO CONSTRUCTION, FIELD VERIFY
DOWNSTREAM INVERTS FOR ALL EXISTING SS AND SD PIPES, AREA DRAINS AND CATCH BASINS WITH
PROPOSED UPSTREAM CONNECTIONS. CONFIRM EXISTING OUTLET INVERTS PROVIDE POSITIVE DRAINAGE
FOR ALL UPSTREAM PIPES. PIPES SHALL BE VERIFIED WITH DYE TEST, CCTV, OR OTHER METHOD
COORDINATED AND APPROVED BY CITY OF RENTON. COORDINATE TESTING WITH CITY.
3. PROJECT ASSUMES THAT ALL CITY EXISTING UTILITY INFRASTRUCTURE IS ADEQUATELY SIZED TO
SUPPORT THE PROJECT.
4. PRIOR TO DEMOLITION, CONTRACTOR SHALL FIELD VERIFY AND LOCATE ALL EXISTING UTILITIES TO REMAIN
WITHIN AND ADJACENT TO LIMIT OF WORK.
5. ALL EXISTING PAVEMENT STRIPING DISTURBED DURING CONSTRUCTION SHALL BE REPLACED IN KIND.
PRODUCTS SHALL BE PER CITY OF RENTON PUBLIC WORKS DEPARTMENT STANDARD PLANS AND
SPECIFICATIONS, AND WSDOT STANDARD PLANS AND SPECIFICATIONS. CONTRACTOR SHALL SUBMIT A
PAVEMENT RESTORATION PLAN INCLUDING, CUTTING AND JOINTING, FOR ALL PAVEMENT BEING
DISTURBED.
6. FULL DEPTH PAVEMENT REPLACEMENT, AND TRENCH RESTORATION AT UTILITY CUTS, SHALL BE PER CITY
OF RENTON STD DETAILS. PAVEMENT SECTION SHALL BE PER CITY OF RENTON STD DETAILS, OR MATCH
EXISTING WHICHEVER IS GREATER. MATCH EXISTING PAVEMENT MATERIAL PER ASSOCIATED STANDARD
DETAILS. TRENCH AND BACKFILL SHALL BE PER CITY OF RENTON RENTON STD. PLAN 220.20. PEDESTRIAN
CONCRETE PAVEMENT SHALL BE PER CITY OF RENTON STD. PLAN 102. VEHICULAR CONCRETE PAVING
SHALL BE PER CITY OF RENTON RENTON STD. PLAN 110, 110.1 AND 111 AND PROJECT DETAILS.
7. PEDESTRIAN CONCRETE, MINIMUM SECTION:
4" CONCRETE
6" CSBC
REFER TO LANDSCAPE FOR CONCRETE SCORING, COLOR, AND FINISHES.
8. THE RENTON MARKET AND PIAllA PROJECT IS REQUIRED TO MEET STORMWATER REQUIREMENTS PER
THE 2022 CITY OF RENTON SURFACE WATER DESIGN MANUAL (RSWDM).
8.1. FLOW CONTROL: THE PROJECT PROPOSES MORE THAN 5,000 SQUARE FEET OF NEW PLUS REPLACED
IMPERVIOUS SURFACE AND IS LOCATED IN THE PEAK FLOW RATE CONTROL STANDARD AREA. TARGET
SURFACES DO NOT GENERATE MORE THAN A 0.15-CFS INCREASE IN THE EXISTING SITE CONDITIONS
100-YR PEAK FLOW, THEREFORE FLOW CONTROL IS NOT REQUIRED.
8.2. WATER QUALITY: THE PROJECT PROPOSES LESS THAN 5,000 SQUARE FEET OF NEW PLUS REPLACED
IMPERVIOUS SURFACE (PGIS), AND LESS THAN % ACRES OF POLLUTANT GENERATION PERVIOUS
SURFACE (PGPS), THEREFORE WATER QUALITY IS NOT REQUIRED.
8.3. ON -SITE BMPS: THE PROJECT PROPOSES MORE THAN 2,000-SF OF NEW PLUS IMPERVIOUS SURFACE,
THEREFORE ON -SITE STORMWATER MANAGEMENT (OSM) IS REQUIRED. ALL AVAILABLE OSM BMP'S
WERE EVALUATED AND ARE NOT FEASIBLE FOR THE SITE.
8.4. THE PROJECT IS LOCATED IN AN AQUIFER PROTECTION AREA, THEREFORE STORMWATER MITIGATION
FACILITIES SHALL NOT INFILTRATE AND SHALL BE COLLECTED VIA STORMWATER CONVEYANCE AND
DISCHARGE TO THE CITY MAIN.
9. GREASE INTERCEPTOR SIZE AND VAULT PER MECHANICAL.
10. ELECTRICAL SERVICE FOR THE SITE IS PER ELECTRICAL.
11. STORM, SEWER, AND WATER INFRASTRUCTURE SHALL BE PER CITY OF RENTON STANDARDS AND WSDOT
STANDARD SPECIFICATIONS, UNLESS OTHERWISE NOTED.
12. STORM DRAINAGE PIPE MATERIAL SHALL BE PER RSWDM TABLE 4.2.1.A2, UNLESS OTHERWISE NOTED.
13. ALL REGULATORY SIGNAGE AND PAVEMENT STRIPING SHALL CONFORM TO CITY OF RENTON AND MUTCD
SPECIFICATIONS.
0 5' 10, 20'
1 inch =10 feet
(% CITY OF
RENTON
vtog
Planning/Building/Public Works Dept.
R-4334010
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
msippo 08/13/2025
WATER UTILITY
ABDOUL GAFOUR 08/13/2025
DATE:
RENTON MARKET & PIAZZA 7/16/2025
CIVIL CONSTRUCTION PERMIT FIELDBOOK:
PAGE:
DRAWING NO:
CIVIL IMPROVEMENT PLAN C3.03
SHEET: 0 OF: