HomeMy WebLinkAboutR-433442,;I- IRRIGATION NOTES — PIAZZA
M 1. IRRIGATION IMPROVEMENTS FOR THE PIAZZA REQUIRE
RENOVATION TO AN EXISTING IRRIGATION SYSTEM.
O CONFIRM THE LOCATION, OPERATIONAL STATUS, AND EXISTING IRRIGATION AT ZONE Al PROPERTY LINE ►
CONDITIONS OF THE EXISTING IRRIGATION PIPING AND SERVICING TREES IS INTENDED TO
FEATURES NOTED FOR RETENTION AND RECONNECTION. ROUTE AND SLEEVE NEW PIPE UNDER MATCH LINE SEE SHEET L4.01
Q REMAIN IN PLACE UNDER EXISTING -
LJJ PROVIDE SYSTEM AS-BUILTS OR A SUMMARY PLAN PAVING. FIELD VERIFY LOCATION NEW PAVEMENT AS NECESSARY TO
��- -- --- �►������� CONECTTOEXISTINGIRRIGATION ��---------- -����-----------�-�--
DETAILING THESE CONDITIONS FOR REVIEW AND APPROVAL OF EXISTING IRRIGATION PIPES AND - - - - - 1 co
PRIOR TO BEGINNING RENOVATION. THIS DOCUMENTATION I CONNECT TO NEW SYSTEM AS aS ,�ECO1D ° PIPING TO REMAIN IN PLACE I M
WILL FORM THE BASIS FOR TESTING REQUIREMENTS FOR SHOWN. REPLACE VALVE WITH -- /� a ° ;' -TERMINQ, PROVIDEAL END OFALLMAINLINES, TYP. N
RENOVATED COMPONENTS. NEW 1" AUTOMATIC CONTROL a °I. O I I \_ ° ----- - =-- v O
2. CONFIRM AVAILABLE WATER PRESSURE AND FLOW, METER VALVE AND WIRE TO NEW _ I O
SIZE AND WATER SUPPLY SIZE AND SUBMIT A REPORT FOR CONTROLLER. '�� r' - - STATION STATION :�-: e I L0
REVIEW PRIOR TO INSTALLING THE IRRIGATION SYSTEM.
3. SELECTIVE DEMOLITION AND PROTECTION ARE REQUIRED
_
TO PREPARE THE EXISTING SYSTEM FOR RENOVATION AND GPM VALVE GPM vALVE
9
TO ACCOMMODATE THE WORK OF OTHER TRADES. THESE g 8— - - - - 19.84 1 _ 2.08 1 _
ACTIVITIES INCLUDE, BUT ARE NOT LIMITED TO CUTTING AND STATION T ° ■
CAPPING OF PIPES, CUTTING, LABELING, AND SPLICING - - — - - — — - _ ---+a- J _ — _ — - — - REUSE EXISTING
IRRIGATION CONTROL WIRES. PROTECTING PLANTING Oil W �.,�`, --- - �,,�` FOUNTAIN
AREAS WHERE IRRIGATION PIPES AND FIXTURES WILL e ° o i PLUMBING
GPM VALVE 4 RE USE EXIST ° TING ,
A ,
REMAIN IN PLACE DURING CONSTRUCTION.-LL.`.W.-.W \Z� a IRRIGATION a ,� PATHWAY TO
I
4. INSTALL, TEST AND RECORD NEW LAYOUT ON DRAWINGS IN 9.58 1 LL y WWW WWLL-WW W WWy W W W W .W.W y ` ,
%� `w METAL ACCESS VAULT AT ° CONTROLLER °. ° I h PROVIDE
ACCORDANCE WITH REQUIREMENTS IN 328400 PLANT w W W ' w LL O , ° IRRIGATION TO
°°
°
f
��.°. ��.°� .-. .�.°��.-. .°��.°. .- JUNCTIONS TO EXISTING e
IRRIGATION. sTATION w _ _ w �� _ w _ AREA
° ° I
°�� Al �� R �� THIS
5. LOCATE THE SUPPLY END OF EACH IRRIGATION LATERAL AT / IRRIGATION LINES. �� �,
Wow °
E �` %a ^ a•°
RENOVATED PLANTING AREAS. CUT AND PREPARE PIPES TO 02 I - w . . . - w - - VALVE AND �"'�� - °
P
°w� �.��� w� PROVIDE GATE ��.�� °�i - I CEO
ALLOW CONNECTIONS FOR EXTENDING NEW IRRIGATION GPM VALVE .-.y�'.y.'.�.'�'.'�'� i�'.�.'.'.i�';y.'.�.`�'.y� QUICK COUPLER AT \ \ i M
INTO THESE AREAS.
8.08 1 . . . . . %W. TERMINATION OF MAINLINE. �,
NEwsPRINKLERANDIRRIGATIONSHALL I �'_'.'_'_'�'_'�'_' w `��-�����-`� �`�����`w�� PROVIDE ADDITIONAL WIRE TO ��. ° ' ATTACH RAIN SENSOR ' ----- ��
BE INSTALLED DOWNSTREAM of THE -' CONTROLLER FOR FUTURE TO LIGHT POLE °
EXISTING AND/OR PROPOSED DCVA ��������� ����������/� ������ ������� �����-�� °° / i
STATION . y . y - . - SYSTEM EXPANSION.
°
ANSIO
- - ° O STATION Q
w
031 a
°� � ��`� �! INSTALL NEW MICROLINE a i
�� .._w.� IRRIGATION AT NEW TREE.
°
. . . . ° d �� al $ I
W - - - - - - - GPM VALVE I .w W W. W W W W.W, l LL..WWWW WWWW. i yWWW y. EXISTING MICROLINE ° ° 1 6 J
r
PROVIDE WATER BAGS AT
9.93 1" �.�.�. �. �.-.�.�.�. . .�.�.�.� IRRIGATION TO BE a a9. a 4 NEW TREE DURING a
W
°
�� REMOVED. ° a p ° ��a GPM VALVE
ESTABLISHMENT PERIOD 12.51 1"
BUBBLERS
Z STATION
04 '
°
,
O ° a ° .. ..
GPM VALVE
°
a
,n
6.0 1 PIPING LOCATION SHOWN IS ° ° ! �. - - - i
J DIAGRAMMATIC. INSTALL ALL .y. W .WW WWW W WW.y.WW I Lu
STATION PIPING WITHIN LANDSCAPE AREAS ..�����.�.�.���������.���.�.�.�.� I 00
.� WHERE POSSIBLE. WHERE PIPING
REPEAT COMMENT: 1" DCVA O
LIMIT OF WORK
Al REQUIRED FORBACKILOW MUST RUN UNDER HARDSCAPING,
�, -- GPM VALVEPREVENTIONw w w w
IROUTE AND SLEEVE AS NEEDED. I O
- — "�
W W W W W W W
5.78 1" �'�'w' � 11 . . / � -v - � � _ � .. _ .. � .. � � �
W
°
WW
PROVIDE SUB -SURFACE
STATION
DRIP LINE PER SOIL CELL .... - - Lu
.. % MANUFACTURERS ..
06 RECOMMENDATION AND
- I � DETAILS TYP.
GPM VALVE MM
�� .`.'.'. .`.".'.`.".`. .`.".......
�� RD)01
W
DCVAW
15
w .
y
w I
W
° e
- - V- .. W .. y u W W W w W W 1.
W
w
w W W W w W W W
W
W
� w W
W
W
,. w W W W w W W W W
_ .. W W .. .. W ..
y W W W W W W W y W W W W y W W W r W y
W W W
� LL
W.
W
y
w
W W W
°
°
• � � 16 29
°
I°
0
. e
W
°
°
° I
°
a
I
I
_IRRIGATION PLAN - PIAZZA
1 If
= 10'-011
IRRIGATION LEGEND
°
°
DRIP
STATION
07 —J
GPM VALVE
2.78 1"
.STATION— —STATION - - FIND AND LOCATE EXISTING PIPING. - � - -
OH O9 SERVICING ZONE A5 TO 3RD STREET ROW S 3
TREES. CONNECT TO NEW IRRIGATION
GPM VALVE GPM VALVE SYSTEM. REPLACE VALVE WITH NEW 1"
7.04 1" 5.04 1" AUTOMATIC CONTROL VALVE AND WIRE TO
NEW CONTROLLER.
POC
IRRIGATION POINT OF CONNECTION -
®
— - —
QUICK COUPLER
- —
SCH 40 PVC MAINLINE, SEE PIPE SIZING CHART
RIGHT OF WAY
0
IRRIGATION CONTROLLER IN LOCKING,
SCH 40 PVC LATERAL, SEE PIPE SIZING CHART
GATE VALVE
STAINLESS STEEL CABINET
SCH 40 PVC SLEEVE (2X LINE SIZE, 4" MIN)
U��In
BACKFLOW PREVENTER
Da
BUBBLER ZONE KIT
r
SUB -SURFACE DRIP IRRIGATION
❑M
MASTER VALVE
AUTOMATIC CONTROL VALVE
PROVIDE DRIP IRRIGATION SYSTEM AT
0
FLOW SENSOR
BUBBLERS
TREE SOIL CELLS WHERE SHOWN ON PLAN.
(2 PER TREE AS SHOWN)
RAINBIRD XFS SUB -SURFACE DRIPLINE
HARD -WIRED RAIN /FREEZE SENSOR
i
_
EVENLY SPACED ±14"-18" IN PLANTERS
(ONE PER CONTROLLER)
J (18" MAX) WITH 0.6GPH EMITTERS @ 12" OC
�!G �144 M. FOR iVC�
co A,
o N o
CO
Fys tiQ a
Fp 9Z EXP.13 PQ`G
�'4NDSCAPE
RD STREET
SPRAY HEAD KEY
—
BUBBLERS
STATION —
10
GPM VALVE
5 1"
STATION
11
STATION
12
GPM VALVE
16.09 1"
STATION
13
GPM
13.32
VALVE
1"
GPM
8_91
VALVE
1"
DESCRIPTION /
SYMBOL
MPR RADIUS RANGE
QUARTER THIRD
HALF
THREE
FULL
RAIN BIRD 1800-SAM-PRS
QUARTER
SPRAYHEADS W/MPR NOZZLES
®
®
5: 3-5 FEET
0 d
A
A
8: 5-8 FEET
e
10: 7-10 FEET
®
❑
r
12: 9-12 FEET
15: 11-15 FEET
NOTE: PROVIDE 12" POP-UP HEIGHT AT PLANTING AREAS AND 4" POP-UP HEIGHT AT LAWN AREAS.
ROTOR IRRIGATION
STATION TYPE
4.0 VALVE SEQUENCE #
GPM VALVE AND CONTROLLER ID
14.0 1"
VALVE
SIZE
GALLONS
PER MINUTE
H E W I TT SURVEYED: SCALE.
VERTICAL: NAVD 1988
DESIGNED: PER PLAN
HORIZONTAL: NAD 1983/1991 CITY OF
ANIlms
106 Lenora Street
Seattle, WA 98121 DRAW": ONE INCH I V I DATUM11%RENTON
(206) 624-8154 CHECKED: AT FULL SCALE
info@hewittseattle.Com NO. REVISION BY DATE APPR AIF NOT ONE INC.
PPROVESCALE ACCORDINGLY Planning/Building/Public Works Dept.
D
— STATION-
14
GPM VALVE
13.27 1 "
--—— — — — — — —
J
PIPE SIZING CHART
SCH 40 PVC MAINLINE / LATERALS
1-1/2" MAINLINE
GAL/MIN PIPE SIZE
0 - 10 3/4"
10 - 16 1"
16-26 1-1/4" R-433442
26 - 35 1-1/2"
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING � �' DEVELOPMENT ENGINEERING
amorganroth 08/12/2025 mSlpp O 08/13/2025 '
WATER UTILITY
ABDOUL GAFOUR 08/13/2025
RENTON MARKET & PIAZZA DATE
07/16/25
CIVIL CONSTRUCTION PERMIT PAGE OOK
PAGE:
DRAWING NO:
L4.02
IRRIGATION PLAN - PIAZZA
SHEET: OF:
42 61