HomeMy WebLinkAboutR-433443M M O W IRRIGATION CONTROLLER IN METAL CABINET AND METAL PEDESTAL. INSTALL CONTROLLER, CABINET AND PEDESTAL PER MANUFACTURER'S RECOMMENDATIONS. CONCRETE PAD: MIN 6" THICKNESS FINISHED GRADE 3" SCH 40 PVC CONDUIT, FITTINGS AND SWEEP ELL 1" SCH 40 PVC CONDUIT, ` FITTINGS AND SWEEP ELL I_ FOR STATION WIRES FOR POWER SUPPLY WIRES TO REMOTE POWER SUPPLY WIRE VALVES AND RAIN SENSOR COMPACTED SUBGRADE NOTES: 1. ALL WIRES TO BE INSTALLED PER LOCAL ELECTRICAL CODES. 2. FIELD LOCATE WITH RESIDENT ENGINEER PRIOR TO INSTALLATION. COORDINATE LOCATION WITH ARCH AND MECH. 4 EXTERNAL PEDESTAL MOUNTED CONTROLLER 1 /2 - 1 -0 MIN. 18" WIDE TRENCH (OR AS REQUIRED TO ALLOW ADEQUATE COMPACTION OF BACKFILL) FINISH GRADE p DETECT -A -TAPE (BLUE) ABOVE uj �z MAINLINE ONLY, 6" BELOW 0 >_ � FINISHED GRADE, SEE SPEC z U)w cn ~ CO w z TRENCH BACKFILL SEE SPEC Lu Lu = N SCH 40 PVC LATERAL LINE o C)A wSCH 40 PVC MAINLINE j BUNDLE CONTROL WIRES 9-p UNDER MAINLINE ON OPPOSITE SIDE FROM SWING JOINTS (WHEN LATERAL AND MAIN SHARE THE SAME TRENCH) NOTE: TAPE CONTROL WIRES TOGETHER BUT DO NOT TAPE BUNDLED WIRES TO MAINLINE IRRIGATION TRENCH 1 1 /2" = V-0" NEW PAVEMENT FINISH GRADE DETECT -A -TAPE (BLUE & RED), 6" BELOW TOP OF TRENCH GRADE OVER EACH PIPE OR CONDUIT, SEE SPEC GRAVEL BACK FILL o TYPE 2 MINERAL AGGREGATE U (1-1/4"MINUS CRUSHED ROCK) 2 SCH 40 PVC SLEEVE WITH MAIN OR N LATERAL LINES & CONTROL WIRES IN SEPARATE CONDUIT &/OR SLEEVE, TYP. WIRES IN SEPARATE SCH 80 PVC i1 ELECTRICAL CONDUIT xv) NOTE: 1. SLEEVES SHALL BE REQUIRED UNDER ALL PAVED AREAS & WALL OR FOOTING PENETRATIONS. 2. SLEEVE ID PIPE SIZE SHALL BE AT LEAST 2 TIMES GREATER THAN THE TOTAL OD SIZES OF INSERTED PIPES. IRRIGATION TRENCH UNDER PAVING 1 1 /2" = V-0" �!` N M. P O PVC z N o � � o i ✓ �O ~ Ory <c, 1_'111 Fp 697 EX9.13" tjG� �gNDSCAPE P 106 Lenora Street Seattle, WA 98121 (206) 624-8154 info@hewittseattle.com 24" COILED SPARE WIRE (DIFFERENT COLOR) INSTALL ONE EXTRA COIL PER VALVE BOX I QX � a N 0 co z z 3" CLEAR N � r� SPECIFIED VAULT FLUSH WITH FINISHED GRADE FINISH GRADE 3M-DBY WATERTIGHT WIRE SPLICES ID TAG SCH 80 PVC UNION (2 PLACES) SCH 40 PVC LATERAL 12" DEEP MIN. CONCRETE PAVING BRICK SUPPORTING VALVE BOX CONTROL WIRES RED AND REMOTE CONTROL VALVE (BUNDLE UNDER WHITE BRASS PER LEGEND & SPECS MAINLINE ON OPPOSITE GATE VALVE 6" OF 1-1/2" WASHED SIDE FROM LATERALS) SCH 80 PVC TEE, ROCK (OR PEA GRAVEL) SCH 40 MAINLINE FITTINGS & ADAPTERS NOTE: 1. CUT 'U' SHAPED NOTCHES IN BOTH SIDES OF VALVE BOX THAT ALLOW 2" MIN CLEARANCE FROM TOP OF PIPE TO TOP OF CUT- OUT. 2. USE TEFLON TAPE ON ALL THREADED FITTINGS. 3. ONLY ONE AUTOMATIC VALVE PER VALVE BOX. 4. VALVE BOX TO REST ON CONCRETE PAVER BRICKS, NO PRESSURE TO BE PLACED ON MAINLINE OR LATERAL LINE. AUTOMATIC CONTROL VALVE 3/411 - 1'-011 HARDWIRED RAIN SENSOR, SEE LEGEND FEMALE ADAPTER (SLIP X FIPT) GALVANIZED 90° EL (1 OF 2) 3/4" GALVANIZED PIPE, PAINT TO MATCH ARCHITECTURAL FINISH WIRE TO IRRIGATION CONTROLLER 11 HARDWIRED RAIN SENSOR 311 -1-0 19 TURF / FINISH GRADE SPECIFIED COMPACTED BACKFILL ROTOR POP- UP SPRINKLER PER PLAN PVC SCH 40 STREET ELLS (3) SWING ARM & HEAD ASSEMBLY 3" - 1'-011 NO. FINI z_ �g N CO NOTCH RISER AS NECESSARY TO FIT CLEANLY OVER TOE NIPPLE 8 GATE VALVE 1If-1-0 11 REVISION SET IRRIGATION HEAD 1" ABOVE TOP OF MULCH IN LANDSCAPE BED AREAS AND AT FINISH GRADE IN TURF AREAS HARDSCAPE, WHERE OCCURS. ADJACENT GRADE VARIES, SEE MATERIALS PLAN PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) PVC SCH 40 TEE OR ELL PVC LATERAL LINE 10" ROUND BOX (GREEN IN COLOR) W/ BOLT DOWN T LID 8" 0 SCH 40 PVC RISER, LENGTH AS REQUIRED 6" DEPTH 3/8" GRAVEL BACKFILL (2) PAVING BRICK AT ALL CORNERS RED & WHITE BRASS GATE VALVE,CENTER WITHIN RISER (SIZE EQUAL TO MAINLINE) SCH 80 PVC SxS UNION, TO LOOSEN OUTWARD AWAY FROM VALVE, BOTH SIDES SCH 40 PVC MAINLINE SCH 80 PVC TOE NIPPLE 1 CUBIC FOOT DRY SUMP LINED WITH FILTER FABRIC AND FILLED WITH 3/8" GRAVEL BACKFILL SURVEYED: DESIGNED: DRAWN: CHECKED: BY DATE APPR �APPROVED: Q N VALVE BOXES W/ LOCKING LIDS 3M-DBY WATERTIGHT SPLICE KIT MASTER VALVE z 2 SPARE WIRE N BRASS UNION (2 PLACES) X Q BRASS PIPE & FITTINGS FROM POC 0 10 X PIPE I.D. MIN FROM FITTING TO FLOW SENSOR BRASS SCH 80 PVC FLOW SCH 80 FITTINGS / 3" OF <-1 -1/2" ADAPTORS WASHED ROCK OVER FILTER FABRIC MASTER VALVE AND FLOW SENSOR 10" ROUND BOX (GREEN IN COLOR) W/ BOLT DOWN T LID 8" 0 SCH 40 PVC RISER, LENGTH AS REQUIRED 6" DEPTH GRAVEL BACKFILL (2) PAVING BRICK CURB STOP ISOLATION VALVE CENTERED WITHIN RISER BRASS TxT UNION, TO LOOSEN OUTWARD AWAY FROM VALVE (BOTH SIDES) FOGTITE #2 METER BOX (CONCRETE WITH LOCKING METAL LID) FINISH GRADE I FLOW z 0 BRAS _ SIDIPE BRASS PIPE FROM DEDUCT METER 112i:q 1 CUBIC FOOT DRY SUMP LINED -" WITH FILTER FABRIC AND FILLED WITH 3/8" GRAVEL BACKFILL 1 PRV/DCVA ASSEMBLY IN #2 METER BOX 1 " = 1'-011 i s-iM�u-i i i-i i i-ice QUICK COUPLER 1 /2" = 1'-011 SCALE. PER PLAN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY FINISH GRADE = 10" ROUND PLASTIC VALVE BOX 1" QUICK -COUPLING VALVE BACKFILL BOX WITH 3/8" WASHED ROCK 1 LEEMCO QUICK COUPLIN STABILIZER BRICK (1 OF 2, TYP.) UNIBODY SWING JOINT, SEE SPECS COMPACTED SUBGRADE PVC MAINLINE VERTICAL: NAVD 1988 HORIZONTAL: NAD 198311991 CITY OF Agfl� 105MIN RENTON DATUM Planning/Building/Public Works Dept. 5 X PIPE I.D. MIN FROM FLOW SENSOR TO FIRST FITTING SUPER SERVICE SEAL SPLICE KIT FLOW SENSOR PE-89 SHIELDED COMMUNICATION CABLE (MAXI WIRE) TO CONTROLLER SCH 80 PVC PIPE co FIRST ELBOW T JOINT OR FITTING (SCH 40 PVC BEYOND) NOTE: TEFLON TAPE ON ALL THREADED FITTINGS PRESSURE REDUCING VALVE; OPTIONAL WHEN PRESSURE IS BELOW 80 PSI, TYP; (FACTORY SET TO 50 PSI) - USE WHEN PRESSURE AT METER IS GREATER THAN 80 PSI UNLESS OTHERWISE NOTED, TYP TEST -COCKS TO BE UPRIGHT AND EASILY ACCESSIBLE PRESSURE GAUGES ON BOTH SIDES OF O - ASSEMBLY L t F ALL BRASS FITTINGS NIPPLES AND UNIONS FEBCO 850U SERIES DCVA/BACKFLOW ASSEMBLY MANUAL 0 BUILD UP WITH BOX DRAIN EXTENSION OR BRICKS VALVES � BRASS PIPE TO MASTER VALVE NOTCH OUT SECTION MIN 6" DEPTH CLEAN DRAIN OF BOX AROUND PIPES ROCK OVER FILTER FABRIC EXISTING WATER METER, SEE UTILITY DWGS CURB STOP ISOLATION VALVE -� BRASS PIPE FROM CURB STOP VALVE TO DCVA PRESSURE REDUCING VALVE PR--, (USE WHEN PRESSURE AT METER EXCEEDS 80 PSI, TYP) 1" DOUBLE CHECK VALVE ASSEMBLY FOGTITE #2 METER BOX W/ADJUSTABLE LOCKING METAL LID QUICK COUPLING VALVE 10X PIPE I.D. MIN. BRASS PIPE TO MASTER CLEARANCE M FROM DCVA G REQUIRED TO MASTER CONTROL VALVE FLOW SENSOR 5X PIPE I.D. MIN. F FLOW SENSOR CLEARANCE 2" PVC MAINLINE TO REQUIRED TO FIRST AUTOMATIC CONTROL JOINT OR FITTING VALVES 1 POINT OF CONNECTION ASSEMBLY DIAGRAM 1 /8 = 1 -o R-433443 IN COMPLIANCE WITH CITY OF RENTON STANDARDS E RRENT PLANNING � DEVELOPMENT ENGINEERING amorganroth 08/12/2025 msippo 08/13/2025 WATER UTILITY ; ABDOUL GAFOUR 08/13/2025 RENTON MARKET & PIAZZA DATE 07/16/25 FIELD CIVIL CONSTRUCTION PERMIT PAGEBOOK PAGE: DRAWING NO: IRRIGATION DETAILS L4.03 SHEET: OF 43 61 coco O O LO A, u CEO co O O N Q J 00 O O N ril