HomeMy WebLinkAboutR-433447M M i C) i W 0 N N T L0 N 0 N 0 w z rr In DESIGN LOADS ALL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE (IBC), 2021 EDITION, AS AMENDED BY THE CITY OF RENTON ALTERATIONS TO THE EXISTING BUILDING ARE IN ACCORDANCE WITH THE INTERNATIONAL EXISTING BUILDING CODE (IEBC) AND THE PRESCRIPTIVE COMPLIANCE METHOD. LIVE LOADS IN ADDITION TO THE DEAD LOADS, THE FOLLOWING FLOOR LIVE LOADS WERE USED FOR DESIGN. LIVE LOAD REDUCTION IS PER IBC SECTION 1607.12. REDUCIBLE UNREDUCIBLE CORRIDORS, STAIRS 100 PSF X SIDEWALKS, DRIVEWAYS 250 PSF X ASSEMBLY AREAS 100 PSF X RETAIL STORES 100 PSF X DINING ROOM, RESTAURANT 100 PSF X LIGHT STORAGE 125 PSF X HEAVY STORAGE 250 PSF X REFER TO TABLE 1607.1 IN THE IBC FOR RELEVANT CONCENTRATED LIVE LOADS. ROOF SNOW LOAD THE ROOF SNOW LOAD IS DETERMINED USING CHAPTER 7 OF ASCE 7 IN ACCORDANCE WITH IBC SECTION 1608 AND WITH THE FOLLOWING FACTORS: MINIMUM DESIGN LOAD 25 PSF WITHOUT DRIFT P9 = 20 PSF Ce = 1.0 Is 1.10 Ct= 1.2 Pf = 17 PSF CS = 1.0 SEISMIC LOADS THE SEISMIC FORCE -RESISTING SYSTEM (SFRS) USED TO RESIST EARTHQUAKE AND WIND LOADS FOR THE NEW SOUTH CANOPY CONSTRUCTION IS COMPRISED OF SPECIAL STEEL MOMENT FRAMES DESIGNED IN ACCORDANCE WITH THE PROVISIONS OF AISC 341 "SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS". EARTHQUAKE DESIGN IS BASED ON THE EQUIVALENT LATERAL FORCE PROCEDURE IN ASCE 7 SECTION 12.8 WITH THE FOLLOWING FACTORS: SITE CLASS F hn = 12 FT RISK CATEGORY III T = 0.2 SECONDS SEISMIC DESIGN CATEGORY D R = 8 le = 1.25 Q = 3 SS = 1.439 g p = 1.3 S, = 0.491 g CS = 0.18 SIDS = 1.15 g V = CsW = 7 KIPS SID1 = 0.73 g TE = 6 SECONDS THE SEISMIC FORCE -RESISTING SYSTEM IS COMPRISED OF THE STRUCTURAL STEEL MEMBERS AND CONNECTIONS IDENTIFIED IN PLAN. NONSTRUCTURAL COMPONENTS DESIGNED PER ASCE 7 CHAPTER 13 INCLUDE THE FOLLOWING COMPONENTS AND PARAMETERS: KITCHEN MARKET STALLS ap = 1 ap = 2.5 RP = 2.5 RP = 2.5 00 = 2 DO = 2 WIND LOADS WIND LOAD IS DETERMINED USING CHAPTERS 26-31 OF ASCE 7 IN ACCORDANCE WITH IBC SECTION 1609 WITH THE FOLLOWING FACTORS: RISK CATEGORY III Kzt = 1.0 EXPOSURE CATEGORY B Ke = 1.0 V = 11O MPH Gep; = 0.18 Vasd = 84 MPH DESIGN WIND PRESSURES FOR DETERMINING FORCES ON COMPONENTS AND CLADDING SHALL BE DETERMINED USING CHAPTER 30 OF ASCE 7 IN ACCORDANCE WITH IBC SECTION 1609 BY THE WASHINGTON STATE REGISTERED PROFESSIONAL ENGINEER WHO IS RESPONSIBLE FOR THE DESIGN OF SUCH ELEMENTS, UNLESS NOTED OTHERWISE ON THE DRAWINGS. SOUTH CANOPY STORY DRIFTS RELATIVE LATERAL DISPLACEMENTS OF THE NEW SOUTH CANOPY WITH RESPECT TO THE LEVEL BELOW (STORY DRIFTS) ARE AS FOLLOWS: SEISMIC: DESIGN STORY DRIFT A = 2.0 % OF STORY HEIGHT ELASTIC STORY DRIFT = DESIGN STORY DRIFT DIVIDED BY Cd/le, WHERE Cd/le = 4.4 SOIL LOADS ALLOWABLE SOIL -BEARING PRESSURE 2000 PSF DL + LL 2660 PSF DL + LL + SEISMIC/WIND GENERAL NOTES SUBMITTALS SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO ANY FABRICATION OR CONSTRUCTION FOR ALL STRUCTURAL ITEMS, INCLUDING THE FOLLOWING: CONCRETE OR MASONRY REINFORCEMENT, PRECAST OR PRESTRESSED CONCRETE ITEMS, EMBEDDED STEEL ITEMS, STRUCTURAL STEEL, STEEL JOISTS, STEEL DECK, SHEAR STUD LAYOUT, METAL GRATING, GLUED -LAMINATED MEMBERS, CLADDING PANELS AND STAIRS. IF THE SHOP DRAWINGS DIFFER FROM OR ADD TO THE DESIGN OF THE STRUCTURAL DRAWINGS, THEY SHALL BEAR THE SEAL AND SIGNATURE OF THE WASHINGTON STATE REGISTERED PROFESSIONAL ENGINEER WHO IS RESPONSIBLE FOR THE DESIGN. DEFERRED SUBMITTALS PER IBC SECTION 107.3.4.1, DRAWINGS AND CALCULATIONS FOR THE DESIGN AND FABRICATION OF ITEMS THAT ARE DESIGNED BY OTHERS SHALL BEAR THE SEAL AND SIGNATURE OF THE WASHINGTON STATE REGISTERED PROFESSIONAL ENGINEER WHO IS RESPONSIBLE FOR THE DESIGN AND SHALL BE SUBMITTED TO THE ARCHITECT AND THE BUILDING DEPARTMENT FOR REVIEW PRIOR TO FABRICATION. DEFERRED SUBMITTALS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING: FALL ARREST ANCHORS EXTERIOR CLADDING SYSTEMS EQUIPMENT ANCHORAGE SEISMIC DESIGN OF NONSTRUCTURAL COMPONENTS SUSPENDED CEILINGS ALTERNATE ANCHORS (WHEN ALTERNATE ANCHORS ARE PROPOSED) LIGHT POLE TENSILE FABRIC STRUCTURE NONSTRUCTURAL COMPONENTS DESIGN, DETAILING AND ANCHORAGE OF ALL NONSTRUCTURAL COMPONENTS SHALL BE IN ACCORDANCE WITH IBC SECTION 1613, ASCE 7 CHAPTER 13, AND THE PROJECT SPECIFICATIONS. NONSTRUCTURAL COMPONENTS DESIGNED BY OTHERS SHALL NOT INDUCE TORSIONAL LOADING INTO SUPPORTING STRUCTURAL MEMBERS WITHOUT ADDITIONAL BRACING OF THOSE MEMBERS TO ELIMINATE TORSIONAL FORCES. TORSIONAL BRACING SHALL BE DESIGNED BY THE NONSTRUCTURAL COMPONENT DESIGNER AND APPROVED BY THE ENGINEER. DESIGN, DETAILING AND CONSTRUCTION OF ALL NONSTRUCTURAL COMPONENTS WHICH ATTACH TO STRUCTURE SHALL ACCOMMODATE CONSTRUCTION TOLERANCES AS ESTABLISHED BY THE STRUCTURAL SPECIFICATIONS. ANY NONSTRUCTURAL COMPONENTS WHICH ATTACH TO MORE THAN ONE LEVEL OF THE STRUCTURE SHALL ALSO ACCOMMODATE THE FOLLOWING RELATIVE MOVEMENTS BETWEEN LEVELS WITHOUT DAMAGE TO THE NONSTRUCTURAL COMPONENTS: 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com STRUCTURAL NOTES CLADDING CLADDING DESIGNED BY OTHERS SHALL BE SUPPORTED AT EACH STORY TO BE CONSISTENT WITH THE DESIGN OF THE BUILDING STRUCTURE. CLADDING DESIGNED BY OTHERS SHALL NOT INDUCE TORSIONAL LOADING INTO SUPPORTING STRUCTURAL MEMBERS WITHOUT ADDITIONAL BRACING OF THOSE MEMBERS TO ELIMINATE TORSIONAL FORCES, UNLESS OTHERWISE APPROVED BY THE ARCHITECT. TORSIONAL BRACING SHALL BE DESIGNED BY THE CLADDING DESIGNER AND APPROVED BY THE ENGINEER. INSPECTION SPECIAL INSPECTION PER IBC CHAPTER 17 SHALL BE PERFORMED BY AN APPROVED TESTING AGENCY AS INDICATED IN THE STATEMENT OF SPECIAL INSPECTIONS AND TESTING. ALL PREPARED SOIL -BEARING SURFACES SHALL BE INSPECTED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT OF REINFORCING STEEL. SOIL COMPACTION SHALL BE SUPERVISED BY AN APPROVED TESTING AGENCY OR GEOTECHNICAL ENGINEER. STRUCTURAL OBSERVATION STRUCTURAL OBSERVATION OF THE SFRS WILL BE PERFORMED BY THE STRUCTURAL ENGINEER OF RECORD IN ACCORDANCE WITH IBC SECTION 1704.6. STRUCTURAL OBSERVATION CONSISTS OF VISUAL OBSERVATION OF THE STRUCTURAL SYSTEMS FOR GENERAL CONFORMANCE TO THE CONSTRUCTION DOCUMENTS AND DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR THE INSPECTIONS REQUIRED BY THE IBC AND AS SHOWN IN THE SPECIAL INSPECTIONS SCHEDULE. CONTRACTOR SHALL PROVIDE A MINIMUM OF 24 HOURS NOTICE BEFORE CONCEALING THE FOLLOWING STRUCTURAL COMPONENTS FROM VIEW: • REINFORCING STEEL FOR THE FIRST PLACEMENT OF THE FOLLOWING ELEMENTS: SFRS FOUNDATIONS • COMPLETION OF FIRST MOMENT FRAME. STRUCTURAL OBSERVATIONS IN ADDITION TO THOSE REQUIRED BY IBC SECTION 1704.6 MAY BE PERFORMED AT THE ENGINEER'S DISCRETION. TIMING OF THESE SHALL BE DISCUSSED AT THE PREINSTALLATION CONFERENCE. SPECIAL CONDITIONS CONTRACTOR SHALL VERIFY ALL LEVELS, DIMENSIONS, AND EXISTING CONDITIONS IN THE FIELD BEFORE PROCEEDING. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR FIELD CHANGES PRIOR TO INSTALLATION OR FABRICATION. IN CASE OF DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THE DRAWINGS, THE CONTRACTOR SHALL OBTAIN DIRECTION FROM THE ARCHITECT BEFORE PROCEEDING. DIMENSIONS NOTED AS PLUS OR MINUS (±) INDICATE UNVERIFIED DIMENSIONS AND ARE APPROXIMATE. NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS OR EXCESSIVE VARIATIONS FROM INDICATED DIMENSIONS. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS --DO NOT SCALE DRAWINGS. DIMENSIONS OF EXISTING CONDITIONS ARE BASED ON RECORD DRAWINGS BY MITHUN, DATED 01/28/2003 AND ARE TO BE FIELD -VERIFIED BY THE CONTRACTOR. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS, EXISTING CONSTRUCTION AND SOIL EXCAVATIONS, AS REQUIRED, AND IN A MANNER SUITABLE TO THE WORK SEQUENCE. TEMPORARY SHORING AND BRACING SHALL NOT BE REMOVED UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS AND MATERIALS HAVE ACHIEVED DESIGN STRENGTH. NO REINFORCING BARS OR EMBEDS IN EXISTING CONSTRUCTION SHALL BE CUT UNLESS DIRECTED TO BY THE ARCHITECT OR AS SHOWN ON THE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. SOILS SEE THE GEOTECHNICAL REPORT BY ASSOCIATED EARTH SCIENCES, INC DATED OCTOBER 31, 2024, FOR MORE COMPLTE INFORMATION. EARTH WORK MATERIAL, BACKFILL AND COMPACTION SHALL BE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL REPORT. OVEREXCAVATE 2' MINIMUM BELOW FOUNDATIONS AND BACKFILL WITH COMPACTED 2 TO 4 INCH ROCK OR AS REQUIRED BY GEOTECHNICAL SPECIAL INSPECTOR. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE ARCHITECT FOR POSSIBLE FOUNDATION REDESIGN. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW FINAL GRADE. EARTHWORK MATERIAL, BACKFILL AND COMPACTION SHALL BE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL SPECIAL INSPECTOR. BACKFILL BEHIND WALLS SHALL NOT BE PLACED BEFORE THE WALLS AND SUPPORTING SLABS ACHIEVE 28 DAY CONCRETE STRENGTH OR THE WALLS ARE TEMPORARILY BRACED. ALL TOPSOIL ORGANICS AND LOOSE SURFACE SOIL SHALL BE REMOVED FROM BENEATH FILL SUPPORTING CONCRETE SLABS OR PAVING. MEMBER SPACING ALL FRAMING MEMBERS SHALL BE EQUALLY SPACED BETWEEN GRID LINES, COLUMNS, AND DIMENSIONED FRAMING UNLESS NOTED OTHERWISE. CONCRETE CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF IBC CHAPTER 19. CONCRETE MIXTURES CONCRETE MIXTURES SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: CONCRETE MIXTURES f'c (PSI) TEST AGE (DAYS) EXPOSURE CLASS USE FTsw C 4,000 28 FO CO INTERIOR SLAB -ON -GRADE, CURBS AND PADS 4,000 28 F1 C1 FOUNDATIONS, PLINTHS CONCRETE MIXTURES SHALL CONFORM TO THE MOST STRINGENT REQUIREMENTS FOR EXPOSURE CLASSES SPECIFIED IN THE TABLE ABOVE AND ACI 318 TABLE 19.3.2.1. WATER -REDUCING ADMIXTURES MAY BE INCORPORATED IN CONCRETE MIX DESIGNS, BUT SHALL CONFORM TO ASTM C 494, AND BE USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. CaC12 OR OTHER WATER-SOLUBLE CHLORIDE ADMIXTURES SHALL NOT BE USED. WATER/CEMENTITIOUS MATERIALS RATIO SHALL BE MEASURED BY WEIGHT AND SHALL BE BASED ON THE TOTAL CEMENTITIOUS MATERIAL. WATER/CEMENTITIOUS MATERIALS RATIO AND WATER CONTENT SHALL BE DETERMINED BY THE SUPPLIER BASED ON STRENGTH REQUIREMENTS AND SHALL NOT EXCEED THE MAXIMUM WATER/CEMENTITIOUS MATERIAL RATIO AND/OR WATER CONTENT IF SHOWN ABOVE OR IN ACI 318 TABLE 19.3.2.1 FOR THE EXPOSURE CLASSES LISTED. FIELD -MEASURED SLUMP SHALL CONFORM TO THE SUBMITTED CONCRETE MIX DESIGN. TOLERANCE OF SLUMP SHALL CONFORM TO ASTM C 94. ALL CONCRETE SUBJECT TO EXPOSURE CLASSES F1, F2 OR F3 SHALL BE AIR ENTRAINED. AIR -ENTRAINING AGENTS SHALL CONFORM TO ASTM C 260. THE PERCENTAGE OF TOTAL AIR SHALL BE ACCORDING TO ACI 318 TABLE 19.3.3.1 WITH A FIELD TOLERANCE OF ±1.5 PERCENT BY VOLUME. THE PERCENTAGE OF TOTAL AIR SHALL BE MEASURED IN THE FIELD AT THE DISCHARGE FROM THE TRUCK. THE CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNS FOR APPROVAL 2 WEEKS PRIOR TO PLACING ANY CONCRETE. THE MIX DESIGN SHALL BE IN CONFORMANCE WITH ACI 318, CHAPTER 19. THE SUBMITTAL SHALL INDICATE WHERE EACH CONCRETE MIX IS TO BE USED ON THE PROJECT, AS WELL AS THE MAXIMUM AGGREGATE SIZE OF EACH MIX. MAXIMUM AGGREGATE SIZE SHALL CONFORM TO THE PROJECT SPECIFICATIONS. CURING IF THE AIR TEMPERATURE WILL EXCEED 75 DEGREES F WITHIN 48 HOURS OF PLACING CONCRETE, A MOIST CURE SHALL BE APPLIED TO THE CONCRETE FOR A PERIOD OF 36 HOURS AFTER FINISHING CONCRETE SURFACES. REFER TO THE PROJECT SPECIFICATIONS FOR CURING REQUIREMENTS. N0. REVISION REINFORCING STEEL DEFORMED BARS ASTM A 615, GRADE 60, UNO SPECIAL DUCTILE QUALITY DEFORMED BARS ASTM A 706, GRADE 60 LOW ALLOY, UNO HEADED DEFORMED BARS ASTM A 970, HEAD TYPE HA REINFORCING SHALL BE SUPPORTED AS SPECIFIED BY THE PROJECT SPECIFICATIONS AND THE CRSI MANUAL OF STANDARD PRACTICE. REINFORCING STEEL SHALL BE DETAILED IN ACCORDANCE WITH ACI STANDARD OF PRACTICE AS OUTLINED IN ACI 315, "GUIDE TO PRESENTING REINFORCING STEEL DESIGN DETAILS". LAP ALL REINFORCING BARS AS NOTED ON THE DRAWINGS. WHERE SPLICE LENGTH IS NOT SHOWN, USE TYPE Lb (Lbt FOR TOP BARS) SPLICE PER DEVELOPMENT AND SPLICE LENGTH SCHEDULE. MECHANICAL SPLICES CALLED OUT ON THE PLANS SHALL BE TYPE 1, UNLESS OTHERWISE NOTED. TYPE 1 SPLICES SHALL DEVELOP 125 PERCENT OF THE YIELD CAPACITY OF THE SPLICED BARS IN BOTH TENSION AND COMPRESSION. TYPE 2 SPLICES SHALL DEVELOP THE SPECIFIED TENSILE STRENGTH OF THE SPLICED BARS IN TENSION IN ADDITION TO MEETING TYPE 1 SPLICE REQUIREMENTS. SUBMIT ICC-ES OR IAPMO UES REPORT VALID FOR THE 2021 IBC DEMONSTRATING COMPLIANCE OF COUPLERS WITH THESE REQUIREMENTS. AT THE CONTRACTOR'S OPTION AND WITH THE ARCHITECT'S APPROVAL, HEADED DEFORMED BARS MAY BE USED IN LIEU OF REINFORCING BARS SHOWN WITH STANDARD 90 OR 180 DEGREE HOOKS AND MECHANICAL SPLICES MAY BE USED IN LIEU OF LAP SPLICES. USE OF HEADED DEFORMED BARS IS SUBJECT TO CONFORMANCE WITH ACI 318 SECTION 25.4.4. USE OF MECHANICAL SPLICES IS SUBJECT TO CONFORMANCE WITH ACI 318 SECTION 18.2.7 AND REQUIRES SUBMITTAL OF AN ICC-ES OR IAPMO UES REPORT VALID FOR THE 2021 IBC. REINFORCING STEEL SHALL HAVE PROTECTION AS FOLLOWS, UNLESS NOTED OTHERWISE: USE COVER NONSTRUCTURAL SLAB -ON -GRADE PER DETAILS FOOTING, GRADE BEAM BOTTOM BARS 3" (CAST AGAINST EARTH) TOP BARS 1 1/2" 2" (#6 AND LARGER WHERE EXPOSED TO EARTH OR WEATHER) SIDE BARS 2" WELDING OF REINFORCING, WHERE APPROVED BY THE ARCHITECT, SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES AND PREHEATED IN ACCORDANCE WITH AWS D1.4, REINFORCING STEEL WELDING CODE. WELDERS AND WELDING PROCEDURES SHALL BE QUALIFIED IN ACCORDANCE WITH AWS D1.4. MATERIALS SHALL CONFORM TO THE FOLLOWING: REINFORCING BARS TO BE WELDED ASTM A 706, GRADE 60, LOW ALLOY WELDING ELECTRODES E80XX NONSHRINK GROUT BASE PLATE GROUT SHALL BE NONSHRINK TYPE WITH MINIMUM f'c = 8,000 PSI. ALL OTHER NONSHRINK GROUT SHALL HAVE MINIMUM f'c = 5,000 PSI. ANCHORS POST -INSTALLED ANCHORS PROVIDE POST -INSTALLED ANCHORS AS SPECIFIED IN THESE DRAWINGS. INSTALL ANCHORS IN ACCORDANCE WITH QUALIFYING REPORT OF EVALUATION SERVICE. ADHESIVE REINFORCING DOWEL MATERIALS ADHESIVE REINFORCING DOWELS (ARD) ASTM A 615, GRADE 60 THREADED ARD ASTM F 1554, GRADE 36 UNO (CARBON STEEL) ASTM A193 68M CLASS 1 (STAINLESS) ANCHOR EMBEDMENT DEPTHS LISTED SHALL BE CONSIDERED EFFECTIVE EMBEDMENT DEPTHS AS DEFINED IN THE ICC-ES OR IAPMO UES EVALUATION REPORTS. PROVIDE ANCHOR LENGTH AND HOLE PER EVALUATION REPORT TO ACCOMMODATE THE EFFECTIVE EMBEDMENT SPECIFIED IN THESE DRAWINGS. SEE DETAIL MECHANICAL AND ADHESIVE ANCHORS SHALL BE ZINC PLATED CARBON STEEL UNLESS NOTED OTHERWISE. MECHANICAL AND ADHESIVE ANCHORS EXPOSED TO WEATHER SHALL BE STAINLESS STEEL. DO NOT DAMAGE EXISTING REINFORCEMENT. IF LOCATION OF REINFORCEMENT IS UNKNOWN, SCAN FOR EXISTING REINFORCING STEEL PRIOR TO DRILLING. USE OF ALTERNATE PRODUCTS, OR OF POST -INSTALLED ANCHORS AT LOCATIONS NOT SHOWN IN THESE DRAWINGS, IS SUBJECT TO THE APPROVAL OF THE ARCHITECT. SUBMIT PROPOSED ANCHORS TO THE ARCHITECT WITH AN ICC-ES OR IAPMO UES REPORT VALID FOR THE 2021 IBC AND DOCUMENTATION SHOWING THAT THE ALTERNATE PRODUCTS PROVIDE EQUIVALENT CAPACITY FOR ALL CONDITIONS IN THIS PROJECT. SUBMITTED ICC-ES AND IAPMO UES REPORTS SHALL DEMONSTRATE THAT THE ANCHORS ARE SUITABLE FOR USE IN CRACKED CONCRETE. WHERE ANCHORS RESIST SEISMIC LOADS OR SUSTAINED TENSION, SUBMITTED ICC-ES AND IAPMO UES REPORTS SHALL DEMONSTRATE THAT THE ANCHORS ARE SUITABLE FOR THE RESISTANCE OF SEISMIC LOADS OR SUSTAINED TENSION (AS APPLICABLE). DOCUMENTATION OF CAPACITY FOR ALTERNATE PRODUCTS MUST BE INCLUDED AS A DEFERRED SUBMITTAL. ADHESIVES SHALL NOT BE INSTALLED PRIOR TO THE CONCRETE REACHING AN AGE OF 21 DAYS AS REQUIRED BY ACI 318. ADHESIVE ANCHORS HORIZONTALLY OR UPWARDLY INCLINED TO SUPPORT SUSTAINED TENSION LOADS SHALL BE INSTALLED BY PERSONNEL CERTIFIED BY THE ACl/CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM, OR EQUIVALENT PROGRAM. SURVE"ED: SCALE: DESIGNED: DRAWN: oNE INGII CHECKED: AT FULI SCAT F IF NOT ONE INCH BY DATE APPR APPROVEK: SCALE ACCORDINGLY VL ERTICANAVD 1988 HOR17ONTAI: NAD 1983/1991 DATUM DRAWING LIST SO.00 STRUCTURAL NOTES AND DRAWING LIST SO.01 STRUCTURAL NOTES SO.02 STRUCTURAL ABBREVIATIONS AND SYMBOLS SO.03 STATEMENT OF SPECIAL INSPECTION AND TESTING SO.04 STATEMENT OF SPECIAL INSPECTION AND TESTING S4.05 SITE TYPICAL DETAILS CITY OF RENTON Planning/Building/Public Works Dept. R-433447 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING msippo 08/13/2025 RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT STRUCTURAL NOTES AND DRAWING LIST DATE: 07/16/25 FIFI DROOK: PAGE DRAWING NO: SO.00 47 61 co N C) C) C) N LJ `71- C) 0 0 N Q N 00 C) 0 0 C) i N