HomeMy WebLinkAboutR-433448co 0 w 0 N N T L0 N 0 N 0 w z rr In STRUCTURAL STEEL REFERENCE SPECIFICATIONS STRUCTURAL STEEL AISC 360 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" HIGH STRENGTH BOLTS RCSC "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH -STRENGTH BOLTS" WELDING AWS D1.1, TYPICAL AWS D1.3 FOR STEEL DECK AND COLD -FORMED FRAMING AWS D1.8 FOR SUPPLEMENTAL SEISMIC PROVISIONS AWS PREQUALIFIED JOINT DETAILS WELDER CERTIFICATION AMERICAN WELDING SOCIETY (AWS) WASHINGTON ASSOCIATION OF BUILDING OFFICIALS (WABO) STEEL JOISTS AND BRIDGING SJI STANDARD SPECIFICATIONS STEEL DECKING ANSI/SDI C "STANDARD FOR COMPOSITE STEEL FLOOR DECK -SLABS" ANSI/SDI RD "STANDARD FOR STEEL ROOF DECK" AISI S100 WITH S2 "NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS" WITH SUPPLEMENT 2 STEEL MATERIALS WIDE FLANGE SHAPES (W AND WT) ASTM A 992 PLATES (PL), BARS ASTM A 36 TYPICAL, ASTM A 572 GRADE 50 WHERE NOTED ANGLES (L), CHANNELS (C AND MC) ASTM A 36 STRUCTURAL TUBES (HSS) ASTM A 500, GRADE C STEEL PIPE ASTM A 53, GRADE B STRUCTURAL BOLTS ASTM F 3125, GRADE A 325 ANCHOR RODS ASTM F 1554, GRADE 36 UNLESS NOTED OTHERWISE THREADED RODS ASTM A 36, UNLESS NOTED OTHERWISE WELDING ELECTRODES 70 KSI, LOW HYDROGEN, TYPICAL 60 KSI, MINIMUM, STEEL DECK STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION SHALL CONFORM TO THE REQUIREMENTS OF IBC CHAPTER 22. ALL MEMBERS ARE TO BE ERECTED WITH NATURAL MILL CAMBER OR INDUCED CAMBER UP, UNLESS OTHERWISE NOTED ON THE PLANS. SUBSTITUTION OF MEMBER SIZES OR STEEL GRADE WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL BY THE ARCHITECT. A MINIMUM OF TWO BOLTS IS REQUIRED FOR ALL BEAM CONNECTIONS. ALTERNATIVE CONNECTIONS TO THOSE SHOWN ON THESE DRAWINGS WILL REQUIRE PRIOR APPROVAL BY THE ARCHITECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ERECTION AIDS AND JOINT PREPARATIONS THAT INCLUDE, BUT ARE NOT LIMITED TO, ERECTION ANGLES, LIFT HOLES AND OTHER AIDS, WELDING PROCEDURES, REQUIRED ROOT OPENINGS, ROOT FACE DIMENSIONS, GROOVE ANGLES, BACKING BARS, COPES, SURFACE ROUGHNESS VALUES, AND UNEQUAL PARTS. PORTIONS OF THE SEISMIC FORCE -RESISTING SYSTEM MEMBERS, AS DEFINED IN DETAIL 1/S5.00, ARE DEFINED AS PROTECTED ZONES AND ARE SUBJECT TO THE FOLLOWING LIMITATIONS: 1. WITHIN THE PROTECTED ZONES, HOLES, TACK WELDS, ERECTION AIDES, AIR -ARC GOUGING, AND UNSPECIFIED THERMAL CUTTING FROM FABRICATION OR ERECTION OPERATIONS SHALL BE REPAIRED AS REQUIRED BY THE ENGINEER. 2. WELDED HEADED STUD ANCHORS AND DECKING ATTACHMENTS THAT PENETRATE THE BEAM FLANGE SHALL NOT BE PLACED ON BEAM FLANGES WITHIN THE PROTECTED ZONES. ARC SPOT WELDS AS REQUIRED TO SECURE DECKING SHALL BE PERMITTED. 3. WELDED, BOLTED, SCREWED OR SHOT -IN ATTACHMENTS FOR PERIMETER EDGE ANGLES, EXTERIOR FACADES, PARTITIONS, DUCT WORK, PIPING OR OTHER CONSTRUCTION SHALL NOT BE PLACED WITHIN THE PROTECTED ZONES. PROTECTION OF STEEL STRUCTURAL STEEL AND CONNECTIONS, INCLUDING PLATES AND OTHER STEEL ITEMS EMBEDDED IN CONCRETE, WHICH ARE EXPOSED TO WEATHER AND NOT TO BE PAINTED ACCORDING TO THE ARCHITECT, SHALL BE HOT -DIPPED GALVANIZED AFTER FABRICATION IN COMPLIANCE WITH ASTM A 123. ALL FIELD WELDS ON GALVANIZED MATERIAL SHALL BE COATED WITH BRUSH APPLIED ZINC -RICH PAINT COMPLYING WITH ASTM A 780. CLEAN AREAS WHERE GALVANIZING IS DAMAGE OR MISSING AND REPAIR WITH ZINC -RICH PAINT COMPLYING WITH ASTM A 780. ZINC -RICH PAINT SHALL BE A MINIMUM OF 4 MILS OF DRY FILM THICKNESS. STRUCTURAL STEEL AND CONNECTIONS SHALL BE FIREPROOFED WHERE REQUIRED BY THE ARCHITECT. PRIMARY AND SECONDARY STRUCTURE ARE TO BE AS DEFINED BY THE IBC. STRUCTURAL MEMBERS SHALL BE ASSUMED TO BE IN A THERMAL UNRESTRAINED CONDITION FOR THE PURPOSES OF DETERMINING FIREPROOFING THICKNESS. UL DESIGN SHALL BE IN ACCORDANCE WITH LRFD DESIGN METHODOLOGY. WHERE SPRAY -APPLIED CEMENTITIOUS FIREPROOFING IS EXPOSED TO WEATHER, STRUCTURAL STEEL SHALL BE CONSIDERED EXPOSED TO WEATHER, AND SHALL BE PROTECTED ACCORDINGLY. ALL COATINGS ARE TO FOLLOW THE SPECIFICATIONS AND PRODUCT MANUFACTURER'S INSTRUCTIONS. WELDING ALL WELDING SHALL BE IN CONFORMANCE WITH AISC AND AWS STANDARDS, AND SHALL BE PERFORMED BY AWS-WABO-CERTIFIED WELDERS. ONLY WELDS THAT ARE PREQUALIFIED, AS DEFINED BY AWS, OR QUALIFIED BY TESTING SHALL BE USED. SHOP DRAWINGS SHALL SHOW ALL WELDING WITH AWS A2.4 SYMBOLS. WELDS SHOWN ON THE DRAWINGS ARE MINIMUM SIZES. INCREASE WELD SIZE TO AWS MINIMUM SIZES BASED ON THICKNESS. MINIMUM WELD SIZE SHALL BE 3/16-INCH, UNLESS NOTED OTHERWISE. THE WELDS SHOWN ARE FOR THE FINAL CONNECTIONS. FIELD WELD SYMBOLS ARE SHOWN WHERE FIELD WELDS ARE REQUIRED BY THE STRUCTURAL DESIGN. WHERE FIELD WELD IS NOT INDICATED, THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING IF A WELD SHOULD BE SHOP OR FIELD -WELDED IN ORDER TO FACILITATE THE STRUCTURAL STEEL ERECTION. WELDING OF THE SEISMIC FORCE -RESISTING SYSTEM SHALL BE EXECUTED IN ACCORDANCE WITH THE PROVISIONS OF AWS D1.8 "STRUCTURAL WELDING CODE - SEISMIC SUPPLEMENT". WELDS ASSOCIATED WITH THE SEISMIC FORCE -RESISTING SYSTEM ARE IDENTIFIED WITHIN THESE DRAWINGS AS FOLLOWS: NOTE WITHIN WELD TAIL D1.8 INDICATES WELDS SUBJECT TO REQUIREMENTS OF D1.8 D1.8-DCW INDICATES DEMAND CRITICAL WELDS SUBJECT TO ADDITIONAL SPECIFIC REQUIREMENTS WITHIN D1.8 WELDS NOTED AS D1.8 SHALL BE MADE WITH FILLER METAL PRODUCING WELDS WITH A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT-LBF AT 0 DEGREES-F AS DETERMINED BY THE APPLICABLE AWS A5 CLASSIFICATION TEST METHOD. FILLER METAL FOR WELDS NOTED AS D1.8-DCW SHALL ALSO HAVE A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 40 FT-LBF AT 20 DEGREES-F AS DETERMINED BY SECTION A3.4B OF AISC 341-16. CONTRACTOR SHALL SUBMIT TO THE BUILDING OFFICIAL THE WELDING PROCEDURE SPECIFICATIONS VERIFYING THESE REQUIREMENTS. REMOVE FINISHES FROM STEEL PRIOR TO COMPLETING WELDED CONNECTIONS. REPAIR FINISHES AS REQUIRED PER "PROTECTION OF STEEL" SECTION ABOVE AND PER THE SPECIFICATIONS. 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com STRUCTURAL NOTES- CONTINUED STEEL DECK STEEL DECK SHALL CONFORM TO ASTM A 653. WHERE THE DECK IS LEFT PERMANENTLY EXPOSED, GALVANIZED COATING SHALL CONFORM TO ASTM A 924, G90. IN OTHER AREAS, GALVANIZED COATING SHALL CONFORM TO ASTM A 924, G60. STEEL DECK SHALL CONFORM TO THE FOLLOWING: f, (PSI) USE 40,000 MINIMUM NONCOMPOSITE STEEL ROOF DECK MINIMUM DECK GAUGES ARE SHOWN ON PLANS AND ARE BASED ON 3-SPAN, UNSHORED CONDITIONS. HEAVIER DECK GAUGES MAY BE REQUIRED FOR CONDITIONS OTHER THAN THESE, DEPENDING ON MANUFACTURER'S AND CONTRACTOR'S LAYOUT. DECK SUPPLIER SHALL VERIFY DECK GAUGES AND CAPACITIES BASED ON ACTUAL DECK LAYOUT AND SPAN CONDITIONS INCLUDING A 10 PSF SUPERIMPOSED DEAD LOAD ALLOWANCE FOR THE STEEL ROOF DECK. DEVIATIONS IN DECK GAUGES FROM THOSE SHOWN SHALL BE SUBMITTED TO THE ARCHITECT, ALONG WITH A VALID ICC REPORT FOR APPROVAL PRIOR TO SHOP DETAILING. DECK WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3, "STRUCTURAL WELDING CODE - SHEET STEEL." WELDERS SHALL BE QUALIFIED BY WABO SHEET STEEL WELDER CERTIFICATION PROGRAM. ARC SPOT WELD SIZES NOTED ARE BASED ON THE NOMINAL (VISIBLE) DIAMETER. CONTRACTOR SHALL PROVIDE CLOSURE PLATES, FLASHING, AND ALL MISCELLANEOUS COLD -FORMED FRAMING NECESSARY TO COMPLETE THE WORK. THE MINIMUM BEARING SHALL BE 2 INCHES. NONCOMPOSITE STEEL ROOF DECK STEEL ROOF DECK SHALL BE OF THE SIZE, GAUGE, AND MINIMUM SECTION PROPERTIES SHOWN ON THE PLANS OR AN APPROVED EQUAL. STEEL ROOF DECK FASTENING SHALL BE AS SHOWN ON THE PLANS. THE MINIMUM END LAP SHALL BE 2 INCHES CENTERED OVER SUPPORTS. SUSPENDED CEILINGS, LIGHT FIXTURES, PIPES, DUCTS, MECHANICAL OR ELECTRICAL EQUIPMENT, OR OTHER UTILITIES SHALL NOT BE SUPPORTED BY THE NONCOMPOSITE STEEL ROOF DECK WITHOUT APPROVAL OF THE ENGINEER. HOLES OR COMBINATIONS OF HOLES IN NONCOMPOSITE STEEL ROOF DECK, WHICH CUT TWO WEBS WHICH ARE CLOSER THAN 24 INCHES ON CENTER IN ANY DECK SPAN, MAY REQUIRE DECK REINFORCEMENT AND REQUIRE DIRECTION FROM THE ENGINEER. COLD -FORMED STEEL, LOAD -BEARING REFERENCE STANDARDS • IBC CHAPTER 22, SECTIONS 2210 AND 2211. • AISI S100 WITH S2 "NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD - FORMED STEEL STRUCTURAL MEMBERS" WITH SUPPLEMENT 2 • AISI S240 "NORTH AMERICAN STANDARD FOR COLD -FORMED STEEL STRUCTURAL FRAMING" • AISI S400 "NORTH AMERICAN STANDARD FOR SEISMIC DESIGN OF COLD -FORMED STEEL STRUCTURALSYSTEMS" SUBMITTALS SUBMIT PRODUCT DATA AND PROOF OF ICC-ES OR IAPMO-UES APPROVAL FOR FRAMING MEMBERS, FASTENERS, AND CONNECTION HARDWARE VALID FOR THE 2021 IBC. ALTERNATE MATERIALS WITH EQUIVALENT SIZE, SHAPE, STRENGTH AND STIFFNESS SHALL BE SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT. FRAMING MEMBERS COLD -FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SIZE, SHAPE, AND GRADE AS INDICATED ON THE DRAWINGS AND IN ACCORDANCE WITH THE STEEL STUD MANUFACTURER'S ASSOCIATION ICC EVALUATION REPORT ESR-3064P. ALL MEMBERS TO HAVE G60 COATING UNLESS NOTED OTHERWISE. ALL EXTERIOR MEMBERS SHALL HAVE G90 COATING. MATERIALS STUDS AND TRACK ASTM A 1003, TYPE H 43 MIL AND THINNER, GRADE 33 54 MIL AND THICKER, GRADE 50 FLOOR JOISTS, ROOF JOISTS AND RIM TRACK TRADEREADY BY CLARKDIETRICH 43 MIL AND THINNER, GRADE 33 54 MIL AND THICKER, GRADE 50 MISCELLANEOUS SHAPES (STRIPS, ASTM A 653, GRADE 50 SHEETS, ANGLES, BRIDGING) SHEET METAL SCREWS FRAMING FASTENERS SHEAR WALL FASTENERS FLOOR AND ROOF DIAPHRAGM FASTENERS WELDING ELECTRODES ASTM C 1513 GRABBER WAFER HEAD GRABBER BUGLE HEAD GRABBER PAN OR HEX HEAD 70 KSI, USE LOW HYDROGEN WHEN WELDING TO STRUCTURAL STEEL FRAMING CONNECTORS CONNECTORS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY AS SPECIFIED IN CATALOG NO. C-CF-2023. PROVIDE THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER UNLESS NOTED OTHERWISE. CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE FASTENERS IN EACH MEMBER SHEET METAL SCREWS FASTENERS SHALL BE SELF -DRILLING AND SHALL EXTEND THROUGH THE CONNECTION WITH A MINIMUM OF 3 EXPOSED THREADS. WELDING WELDING OF COLD -FORMED STEEL SHALL CONFORM TO AWS D1.3 AND SHALL BE PERFORMED BY AWS-WABO CERTIFIED WELDERS. GALVANIZING GALVANIZE ALL MEMBERS IN ACCORDANCE WITH ASTM A 653, G60. COLD -FORMED STEEL ANCHORS TO CONCRETE AND STEEL WHERE INDICATED ON THE DRAWINGS, PROVIDE ANCHORS PER THE FOLLOWING TABLE. USE OF ALTERNATE PRODUCTS IS SUBJECT TO THE APPROVAL OF THE ARCHITECT. SUBMIT PROPOSED ANCHORS TO THE ARCHITECT WITH AN ICC-ES OR IAPMO LIES REPORT VALID FOR THE 2021 IBC. REFERENCE THE ANCHORS SECTION FOR ADDITIONAL REQUIREMENTS. COLD -FORMED STEEL ANCHORS TO CONC AND STEEL APPLICATION PRODUCT DIAMETER EMBED MIN EDGE MIN EVALUATION DISTANCE SPACING REPORT PAF H6P FULLSTEEL TO STEEL X S16P8TH 0.145" PENETRATION 1/2" 1" SR-175 ESR 1752 (3/16" MIN) CONCRETE SIMPSON ICC-ES SCREW TITEN HD 3/8" 2 1/2" 2 3/4" 3" ESR-2713 ANCHOR N0. REVISION STUD PUNCHOUTS STUD PUNCHOUTS SHALL BE SPACED 24" OC AT MINIMUM. THE FIRST PUNCHOUT SHALL BE A MINIMUM OF 10" AWAY FROM THE ENDS OF EACH STUD. BUNDLED STUDS TWO STUDS IN A BOXED CONFIGURATION, OR STUD GROUPS OF 3 OR MORE MEMBERS, SHALL BE SHOP WELDED WITH 1/8" FLARE GROOVE WELDS x 1/2" LONG, BOTH SIDES AT 12" OC. INSULATION PROVIDE INSULATION IN BOXED OR BUILT-UP FRAMING MEMBERS AS REQUIRED BY THE ARCHITECTURAL DRAWINGS. COLD -FORMED STEEL JOISTS JOISTS ARE ASSUMED TO HAVE FULL LATERAL SUPPORT WITH DECKING ATTACHED TO THE COMPRESSION FLANGE. JOIST ENDS MUST BE BRACED BY RIM TRACK OR BLOCKING. MINIMUM 3 1/2" JOIST BEARING WIDTH AT WALLS. ADD WEB STIFFENER IF BEARING WIDTH IS LESS THAN 3 1/2". RATED SHEATHING WOOD STRUCTURAL PANELS SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST EDITION OF U.S. DEPARTMENT OF COMMERCE (DOC) PS-1 "CONSTRUCTION AND INDUSTRIAL PLYWOOD" OR DOC PS-2 "PERFORMANCE STANDARD FOR WOOD -BASED STRUCTURAL -USE PANELS". EACH PANEL SHALL BEAR THE APA GRADE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION. HARD LID SHEATHING 15/32" 48/24 C-D INT APA WITH EXTERIOR GLUE (CDX) SHEAR WALL SHEATHING 15/32" 32/16 STRUCT 1, EXPOSURE 1 UNO ALL HARD LID SHEATHING AND SUBFLOORING SHALL BE INSTALLED FACE GRAIN PERPENDICULAR TO SUPPORTS OR AS INDICATED ON THE DRAWINGS. ROOF AND SUBFLOORING SHEATHING SHALL BE UNBLOCKED OR AS INDICATED ON DRAWINGS. INSTALL WITH 1/8" GAP BETWEEN PANELS. SHEAR WALL SHEATHING SHALL BE BLOCKED AT ALL PANEL EDGES AS INDICATED IN THE SHEAR WALL SCHEDULE, UNLESS NOTED OTHERWISE. ERECTION 1. EACH JOIST, RAFTER, ROOF TRUSS, AND WALL STUD SHALL BE IN VERTICAL ALIGNMENT OVER THE ENTIRE BUILDING HEIGHT. 2. STUDS SHALL BE SEATED INTO THE TOP AND BOTTOM TRACKS WITH LESS THAN 1/16" GAP BETWEEN THE END OF THE STUD AND THE WEB OF THE TRACK. 3. HANDLING AND LIFTING OF PREFABRICATED PANELS SHALL NOT CAUSE PERMANENT DISTORTION TO ANY MEMBER. FIELD CUTS AND NOTCHES FIELD CUTS OR NOTCHES OF ANY KIND ARE NOT PERMITTED IN LOAD -BEARING COLD - FORMED STEEL MEMBERS. IF A FIELD CUT IS REQUIRED, THE CONTRACTOR SHALL RECEIVE DIRECTION FROM THE ARCHITECT PRIOR TO CUTTING. PERMANENT WALL BRIDGING WALL BRIDGING AND BRIDGING ANCHORAGE SHOWN IN THESE DRAWINGS SHALL BE CONSIDERED AS PERMANENT. THIS BRIDGING MUST BE IN PLACE PRIOR TO APPLYING AXIAL LOAD TO STUDS. WOOD WOOD CONSTRUCTION SHALL CONFORM TO ALL REQUIREMENTS OF IBC CHAPTER 23 SAWN LUMBER SAWN LUMBER SHALL CONFORM TO THE LATEST EDITION OF "GRADING AND DRESSING RULES" BY WCLIB OR "WESTERN LUMBER GRADING RULES" BY WWPA. LUMBER SHALL BE SEASONED DRY WITH A MAXIMUM MOISTURE CONTENT OF **15%** "19%" AND BE THE SPECIES AND GRADE SPECIFIED BELOW. USE GRADE Fb (PSI) (SINGLE USE) PLANKING & PLATES 2" TO 4" THICK, 2" AND WIDER HEM -FIR NO. 2 850 DOUGLAS FIR -LARCH NO. 2 900 JOISTS & RAFTERS 2" TO 4" THICK, 2" AND WIDER HEM -FIR NO. 2 850 DOUGLAS FIR -LARCH NO. 2 900 BEAMS & STRINGERS 5"x5" AND LARGER DOUGLAS FIR -LARCH NO. 1 1,350 WOOD FASTENERS AND CONNECTORS WOOD CONNECTORS SHALL BE SIMPSON STRONG -TIE AS SPECIFIED IN CATALOG NO. C-C-2021, OR APPROVED EQUAL. INSTALL CONNECTORS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS WITH NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE FASTENERS IN EACH MEMBER. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A 307. PROVIDE STANDARD WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. ALL SHIMS SHALL BE SEASONED DRY AND BE THE SAME GRADE (MIN) AS THE MEMBERS CONNECTED. ALL JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH LU SERIES JOIST HANGERS, UNLESS NOTED OTHERWISE. ALL DOUBLE AND TRIPLE -JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH U SERIES HANGERS, UNLESS NOTED OTHERWISE. ALL FRAMING NAILS SHALL HAVE THE SIZE AND MINIMUM LENGTH AS SPECIFIED IN THE FOLLOWING TABLE, UNLESS NOTED OTHERWISE. NAIL TYPE SHALL BE COMMON UNLESS NOTED OTHERWISE. POWER -DRIVEN NAILS AND STAPLES SHALL BE IN ACCORDANCE WITH ICC-ES ESR-1539. NAILING NOT SHOWN SHALL BE AS INDICATED IN IBC TABLE 2304.10.2. FRAMING NAILS TYPE MARK TYPE SHANK DIAMETER MINIMUM LENGTH 8d COMMON 0.131" 21/2" 10d COMMON 0.148" 3" 16d COMMON 0.162" 31/2" 16d-SHORT SHORT 0.131" 31/4" POWER -DRIVEN NAILS MAY BE SUBSTITUTED FOR COMMON NAILS AT SPACING AS FOLLOWS. SUBSTITUTIONS FOR NAIL SIZE, SPACING, OR QUANTITY NOT SHOWN REQUIRE APPROVAL. SURVEYED: SCALE: DESIGNED: DRAWN: oLF 9C CHECKED: AT FULI SCATF IF NOT ONE INCH BY DATE APPR APPROVED: SCALE ACCORDINGLY ALTERNATE NAILING SCHEDULE FASTENER TYPE SHANK DIAMETER LENGTH SPACING 8d COMMON 0.131" 2 1/2" 16" 12" 8" 6" 4" 3" 2" 16d SHORT 0.131" 3 1/4" 16" 12" 8" 6" 4" 3" 2" 10d COMMON 0.148" 3" 16" 12" 8" 6" 4" 3" 2" 16d SHORT 0.131" 3 1 /4" 12" 10" 6" 4" 3" 2 1/2" 1 1/2" 16d COMMON 0.162" 3 1/2" 16" 12" 8" 6" 4" 3" 16d SHORT 0.131" 3 1 /4" 10" 8" 5" 4" 2 1/2" 2" ALL FASTENERS AND CONNECTORS IN CONTACT WITH PRESERVATIVE -TREATED LUMBER SHALL BE GALVANIZED WITH A MINIMUM COATING OF 1.85 OUNCES/SQUARE FOOT. PRESERVATIVE -TREATED WOOD WOOD SHALL BE PROTECTED FROM DECAY AND TERMITES IN ACCORDANCE WITH IBC 2304.12. PRESERVATIVE -TREATMENTS SHALL CONFORM TO THE APPROPRIATE STANDARDS OF THE AWPA FOR SAWN LUMBER, GLUED -LAMINATED TIMBER, ROUND POLES, PILES, AND MARINE PILES AND SHALL BEAR A TREATMENT IDENTIFICATION MARK BY THE CERTIFYING AGENCY. THE SELECTED PRESERVATIVE -TREATMENT SHALL CONFORM TO THE "BEST MANAGEMENT PRACTICES" OF THE WWPI. ALL LUMBER IN CONTACT WITH CMU, CONCRETE, OR GROUND SURFACES SHALL BE PRESERVATIVE -TREATED. PRESERVATIVE TREATMENT SHALL NOT REDUCE ALLOWABLE DESIGN STRESSES. LUMBER SHALL ALSO BE TREATED TO THE M4-16 (FIELD TREATMENT) STANDARD. R-433448 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING � �' msippo 08/13/2025 %j DATE: VERTICA° NAVD 1988 RENTON MARKET &PIAZZA HORI7ONTAI : NA° 1983�1991 CITY OF 07/16/25 CIVIL CONSTRUCTION PERMIT FIFIDRODK %R]R E N TO N PAGF DATUM DRAWING NO: Planning/Building/Public Works Dept. S0.01 STRUCTURAL NOTES SHFFT: OF. 48 61 co C) C) N LJ N 0 0 0 C) i N