Loading...
HomeMy WebLinkAboutT-433401It C'7 C'7 T �i PIPE EXTERIOR FACE O rr 1/16" MAX GAP AT PERIMETER 1/4" BEVEL REMOVABLE ACCESS DOOR, MATCH PIPE PROFILE 1/4"0 GALV SECURITY SCREW W/ RECESSED HEAD T&B, CTR ON PL N 3 SIDES r 1/8 CURVED PL 1/4x2x0'-4 1/2" OPENING T&B; DRILL AND TAP TO 4" WIDE x 9" TALL W/ 1/2" RECEIVE SECURITY SCREW d RADIUSED CORNERS SECTION AT ACCESS DOOR 3" = 1'-0" 3/4"0 MAX HOLE W/ SEALING GROMMET, COORD SIZE AND LOC WITH ELECTRICAL; SUBMIT SEALING GROMMET TO ARCHITECT FOR REVIEW PIPE EXTERIOR FACE PL 3/8" ACS1 COMPACT ADJUSTER AND CLEVIS PER RONSTAN 1 OR APPROVED 1 EQUIVALENT /`-3/4" R SPIRAL #4 @ 4" OC, DEVELP SPIRAL W/ 1 1/2 EXTRA TURNS AT EACH END OF CAGE (6) #5 VERTSDISTRIBUTED UNIFORMLY AROUND COLUMN PERIMETER 12" 0 ANCHOR BOLTS PER LIGHT POLE MFR TYPICAL LIGHT POLE PLINTH 0 #4@4"OCTIE CABLE PER 11/S4.05 3/16 (12) #7 VERTS V4" 3/16 JV ` \-1 1/2" NOTES: 1. ORIENT TAB TO ALIGN WITH CATENARY CABLE LAYOUT PER LANDSCAPE ARCHITECT. CATENARY CABLE CONNECTION z N r w J_ Ll Q co O r- Ln O L( ) N 0 N_ Ln 0 w z it w 3" = 1'-0" POLE PER 11/S4.05 TYP MAX 25 LB LIGHT, (2) LOCS PER CABLE CATENARY LIGHT CABLE PROFILE 1/16" = 1'-0" 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 2'-0" LOGAN AVE PLINTH 1 " = 1'-0" (4) 1"0 GR 105 GALV ANCHOR RODS W/ 24" EMBED PL1 1 /2x16x1'-4" a_ N } 0 N POLE PER 11/S4.05 3/8 O 1.5" 0 MAX HOLE, COORD WITH ELECTRICAL 2" — ... PLINTH PER 6/S4.05 LOGAN AVE POLE BASEPLATE 1 " = V-0" NO. REVISION ROUNDED CAP PL 1/8" W/ 8" RADIUS PIPE 10 X-STRONG AESS POLE CAN ACCOMODATE MAX 2'-0" x 4'-0" DECORATIVE BANNER POLE CAN ACCOMODATE (2) 60 LBS MAX DECORATIVE FLOWER BASKETS X cQc /C W r ACCESS DOOR PER 1/S4.05 FOR OUTLET, COORD W/ ELECTRICAL CL POLE SEAL WELD CATENARY CONN CABLE PER 5/S4.05 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I TT 1 _�__= 1 -7�_ I ACCESS DOOR PER 1/S4.05, LOCATE PER LANDSCAPE ARCH BASE PL PER 10/S4.05 PLINTH TIES AND VERTS PER 6/S4.05 SIDEWALK PER CIVIL T/SIDEWALL _ N O T O r N N I CATENARY LIGHTS AND CABLE PROFILE PER 9/S4.05 RONSTAN ACSI-SS-08 OR FOR APPROVED EQUIVALENT 1 1 (4) 3/8"0 WEEP o I HOLES EQ SPACED 9 I AROUND BASE I 1 ESCUTCHION COVER PLATE 1 PER LANDSCAPE 1 2'-0 ; ARCH I 1 z I cr =� 1 1 I O0 I I z(D I N r - N � 6 S4.05 (8) #8 VERT T&B 8'-0"x5'-0"x30" FOUNDATION (8) #8 HORIZ T&B COMPACTED STRUCTURAL 8'-0" FILL PER GENERAL NOTES NOTES: 1. LOCATE LOGAN AVE POLES PER CIVIL. 2. CONTRACTOR TO COORDINATE FOUNDATION LOCATIONS WITH EXISTING UTILITIES AND CIVIL DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPNACIES. 3. PAINT PER LANDSCAPE ARCHITECT. LOGAN AVE POLE ELEVATION 1/2" = V-0" SURVEYED: DESIGNED: DRAWN: CHECKED: BY DATE A P P R APPROVED: 0 N N 0 0 0 N pp r N r PLANTER SOIL zo c0 N r r r CL POLE CL FOOTING F -1 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I co N O O O Ln N ARE Q0 co O O 0 N Q J LIGHT POLE PER N LANDSCAPE ARCH CID O O O N ANCHOR BOLTS PER LIGHT POLE MFR 5'-0"x5'-0"x24" FOUNDATION PLINTH TIES AND VERTS PER 2/S4.05 (5) #4 OC EW, T&B COMPACTED STRUCTURAL FILL PER GENERAL NOTES 5-0" NOTES: 1. LOCATE MAST POLES PER LANDSCAPE ARCHITECT. 2. CONTRACTOR TO COORDINATE FOUNDATION LOCATIONS WITH EXISTING UTILITIES AND CIVIL DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPNACIES. SCALE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 CITY OF RENTON °NE INCH DATU M AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY TYP MAST LIGHT POLE ELEVATION 1/2" = V-0" T-433401 IN COMPLIANCE WITH CITY OF RENTON STANDARDS EDEVELOPIMENT ENGINEERING o 08/13/2025 DATE: RENTON MARKET & PIAZZA 07/16/25 CIVIL CONSTRUCTION PERMIT FPAAGE:CE: OK: DRAWING NO: 05 SITE TYPICAL DETAILS S4. SHEET: OF: 52 61