Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T-433406
SHEET NOTES Add standard details 119,120,124,139 and J013 to plan set. (N) CATENARY LIGHT FIXTURES, TYPE F2 (TYP OF 8) (N) POLES FOR CATENARY LIGHTS, RECEPTACLES, AND COMMS (TYP OF 6) A. ALL SITE POWER AND LIGHTING IS POWERED VIA EXISTING 240/120V PANELS E1 AND E2, LOCATED ON THE NORTH WALL OF THE MAIN ELECTRICAL ROOM. B. EXISTING CONDUIT RETAINED FROM THE DEMOLITION OF SITE POWER AND LIGHTING TO BE EXTENDED WHENEVER POSSIBLE TO NEW RECEPTACLES AND LIGHT FIXTURES KEYED NOTES 1❑ PROVIDE (2) 1" CONDUIT FOR LOW VOLTAGE EQUIPMENT TO EACH POLE �2 EACH MAST POLE HAS (5) LIGHT FIXTURE HEADS AND (1) GFCI DUPLEX RECEPTACLE. EACH POLE RECEIVES (2) CIRCUITS IN (2) 3/4" CONDUIT. EXISTING CONDUIT TO BE EXTENDED WHERE POSSIBLE. �3 RECEPTACLE INTEGRAL TO MAST POLE, AND IS PROVIDED BY OTHERS. ® MOUNT NEMA-3R ENCLOSURE TO SIDE OF STAGE. ENCLOSURE SIZED TO CONTAIN ALL (3) RECEPTACLES. EXACT LOCATION TO BE CONFIRMED BY ARCHITECT. �5 PROVIDE NEW RECEPTACLE IN LANDSCAPING. EXTEND EXISTING CONDUIT FROM DEMOLISHED RECEPTACLE TO NEW RECEPTACLE LOCATION. STUB CONDUIT UP INTO CAST METAL BOX WITH WHILE -IN -USE COVER. © EXTEND CONDUIT UNDERGROUND TO NEW MAST LIGHT POLE. �7 PROVIDE NEW RECEPTACLE IN LANDSCAPING. EXTEND EXISTING CONDUIT FROM DEMOLISHED LIGHT POLE TO NEW RECEPTACLE LOCATION. STUB CONDUIT UP INTO CAST METAL BOX WITH WHILE -IN -USE COVER. ® MANUAL LIGHTING CONTROLS FOR PIAZZA LIGHTING. COORDINATE FINAL LOCATION WITH BUILDING ARCHITECT. �9 PROVIDE SWITCH FOR SITE RECEPTACLES. COORDINATE LOCATION AT EDGE OF PLANTER WHERE FORMER FOUNTAIN CONTROLS BOX IS LOCATED. 10 ROUTE CONDUIT SO THAT IT DOES NOT ENCROACH ON EXISTING TREE CRITICAL ROOT ZONES. REFER TO ARBORIST REPORT. 11 DEDICATED RECEPTACLE FOR HOLIDAY TREE LIGHTING. 12 FINAL CIRCUITING REQUIREMENTS AND CIRCUIT ROUTING TO BE COORDINATED WITH WORLD CUP LEGACY SQUARE DESIGNERS AND CITY OF RENTON. "#" REPRESENTS FUTURE CIRCUIT NUMBER, TO BE COORDINATED. Time clock for catenary lights shall be attached to service cabinet and maintained by Transportation Maintenance. T-433406 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING A' msippo 08/13/2025 N ELECTRICAL SITE PLAN SCALE: 1" = 20'-0" U SURVEYED: SCALE: DATE: / 16 / 2025 1 =25 -0 VERTICAL: NAVD 1988 j;ej CITY OF RENTON MARKET &PIAZZA 11 1 11 HORIZONTAL: NAD 1953/1991 DESIGNED: CIVIL CONSTRUCTION PERMIT FIELDBOOK: Arup US, Inc. 811 DRAWN: RENTON PAGE: IsCall DRAWING NO: Seat Second Avenue Suite 400 ONE INCH DATUM ELECTRICAL - SITE POWER PLAN- rnSeattle WA 98101 two business days CHECKED: AT FULL SCALE r � . 00 T+1 2064932258 F + 1 2067490665 y IF NOT ONE INCH Planning/Building/Public Works Dept. 1 before you dig NO. REVISION BY DATE APPR PIAZZA APPROVED: SCALE ACCORDINGLY F HEET57 OF: 61