It C'7 C'7 T �i PIPE EXTERIOR FACE O rr 1/16" MAX GAP AT PERIMETER 1/4" BEVEL REMOVABLE ACCESS DOOR, MATCH PIPE PROFILE 1/4"0 GALV SECURITY SCREW W/ RECESSED HEAD T&B, CTR ON PL N 3 SIDES r 1/8 CURVED PL 1/4x2x0'-4 1/2" OPENING T&B; DRILL AND TAP TO 4" WIDE x 9" TALL W/ 1/2" RECEIVE SECURITY SCREW d RADIUSED CORNERS SECTION AT ACCESS DOOR 3" = 1'-0" 3/4"0 MAX HOLE W/ SEALING GROMMET, COORD SIZE AND LOC WITH ELECTRICAL; SUBMIT SEALING GROMMET TO ARCHITECT FOR REVIEW PIPE EXTERIOR FACE PL 3/8" ACS1 COMPACT ADJUSTER AND CLEVIS PER RONSTAN 1 OR APPROVED 1 EQUIVALENT /`-3/4" R SPIRAL #4 @ 4" OC, DEVELP SPIRAL W/ 1 1/2 EXTRA TURNS AT EACH END OF CAGE (6) #5 VERTSDISTRIBUTED UNIFORMLY AROUND COLUMN PERIMETER 12" 0 ANCHOR BOLTS PER LIGHT POLE MFR TYPICAL LIGHT POLE PLINTH 0 #4@4"OCTIE CABLE PER 11/S4.05 3/16 (12) #7 VERTS V4" 3/16 JV ` \-1 1/2" NOTES: 1. ORIENT TAB TO ALIGN WITH CATENARY CABLE LAYOUT PER LANDSCAPE ARCHITECT. CATENARY CABLE CONNECTION z N r w J_ Ll Q co O r- Ln O L( ) N 0 N_ Ln 0 w z it w 3" = 1'-0" POLE PER 11/S4.05 TYP MAX 25 LB LIGHT, (2) LOCS PER CABLE CATENARY LIGHT CABLE PROFILE 1/16" = 1'-0" 1601 5th Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 www.kpff.com 2'-0" LOGAN AVE PLINTH 1 " = 1'-0" (4) 1"0 GR 105 GALV ANCHOR RODS W/ 24" EMBED PL1 1 /2x16x1'-4" a_ N } 0 N POLE PER 11/S4.05 3/8 O 1.5" 0 MAX HOLE, COORD WITH ELECTRICAL 2" — ... PLINTH PER 6/S4.05 LOGAN AVE POLE BASEPLATE 1 " = V-0" NO. REVISION ROUNDED CAP PL 1/8" W/ 8" RADIUS PIPE 10 X-STRONG AESS POLE CAN ACCOMODATE MAX 2'-0" x 4'-0" DECORATIVE BANNER POLE CAN ACCOMODATE (2) 60 LBS MAX DECORATIVE FLOWER BASKETS X cQc /C W r ACCESS DOOR PER 1/S4.05 FOR OUTLET, COORD W/ ELECTRICAL CL POLE SEAL WELD CATENARY CONN CABLE PER 5/S4.05 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I TT 1 _�__= 1 -7�_ I ACCESS DOOR PER 1/S4.05, LOCATE PER LANDSCAPE ARCH BASE PL PER 10/S4.05 PLINTH TIES AND VERTS PER 6/S4.05 SIDEWALK PER CIVIL T/SIDEWALL _ N O T O r N N I CATENARY LIGHTS AND CABLE PROFILE PER 9/S4.05 RONSTAN ACSI-SS-08 OR FOR APPROVED EQUIVALENT 1 1 (4) 3/8"0 WEEP o I HOLES EQ SPACED 9 I AROUND BASE I 1 ESCUTCHION COVER PLATE 1 PER LANDSCAPE 1 2'-0 ; ARCH I 1 z I cr =� 1 1 I O0 I I z(D I N r - N � 6 S4.05 (8) #8 VERT T&B 8'-0"x5'-0"x30" FOUNDATION (8) #8 HORIZ T&B COMPACTED STRUCTURAL 8'-0" FILL PER GENERAL NOTES NOTES: 1. LOCATE LOGAN AVE POLES PER CIVIL. 2. CONTRACTOR TO COORDINATE FOUNDATION LOCATIONS WITH EXISTING UTILITIES AND CIVIL DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPNACIES. 3. PAINT PER LANDSCAPE ARCHITECT. LOGAN AVE POLE ELEVATION 1/2" = V-0" SURVEYED: DESIGNED: DRAWN: CHECKED: BY DATE A P P R APPROVED: 0 N N 0 0 0 N pp r N r PLANTER SOIL zo c0 N r r r CL POLE CL FOOTING F -1 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I co N O O O Ln N ARE Q0 co O O 0 N Q J LIGHT POLE PER N LANDSCAPE ARCH CID O O O N ANCHOR BOLTS PER LIGHT POLE MFR 5'-0"x5'-0"x24" FOUNDATION PLINTH TIES AND VERTS PER 2/S4.05 (5) #4 OC EW, T&B COMPACTED STRUCTURAL FILL PER GENERAL NOTES 5-0" NOTES: 1. LOCATE MAST POLES PER LANDSCAPE ARCHITECT. 2. CONTRACTOR TO COORDINATE FOUNDATION LOCATIONS WITH EXISTING UTILITIES AND CIVIL DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPNACIES. SCALE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 CITY OF RENTON °NE INCH DATU M AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY TYP MAST LIGHT POLE ELEVATION 1/2" = V-0" T-433401 IN COMPLIANCE WITH CITY OF RENTON STANDARDS EDEVELOPIMENT ENGINEERING o 08/13/2025 DATE: RENTON MARKET & PIAZZA 07/16/25 CIVIL CONSTRUCTION PERMIT FPAAGE:CE: OK: DRAWING NO: 05 SITE TYPICAL DETAILS S4. SHEET: OF: 52 61 PIAZZA LIGHTING SEQUENCE OF OPERATIONS SPACE TYPE �O �QG `O� �� JQ �� BOG O�� �' O�� O�' DESCRIPTION O� �Q GG �O G �yJ �0 ��� O� G�� O��C, 0���GO EXTERIOR LIGHTING PHOTOCELL TURNS LIGHTS ON/OFF. TIMECLOCK PROVIDES ADDITIONAL AFTER HOURS CONTROL. PIAZZA X 50 fc T1 X L1 X MANUAL CONTROLS TO ALLOW FOR MANUAL OVERRIDE. SCENE CONTROL FOR GOBO PROJECTOR FIXTURE HEADS. LOGAN STREET CATENARY X 50 fc T1 X L1 PHOTOCELL TURNS LIGHTS ON/OFF. TIMECLOCK PROVIDES ADDITIONAL AFTER HOURS CONTROL. MANUAL CONTROLS TO ALLOW FOR MANUAL OVERRIDE. SEE SPECIFICATION SECTION 26 0993 FOR DEFINITIONS & OTHER REQUIREMENTS LIGHTING SEQUENCE OF OPERATIONS NOTES 1. ALL LIGHTING CONTROLS WHICH REDUCE LIGHTING POWER SHALL MAINTAIN A REASONABLY UNIFORM ILLUMINATION PATTERN. 2. BUILDING IS DESIGNATED LIGHTING ZONE '2' FOR THE PURPOSES OF EXTERIOR LIGHTING CONTROL, AS DESCRIBED IN WSEC TABLE 405.5.3(1). DIMMING REQUIRED LUMINAIRES IN THIS SPACE SHALL BE PROVIDED WITH DIMMABLE DRIVERS. DAYLIGHT RESPONSE AUTOMATICALLY RAISE OR LOWER LIGHT OUTPUT TO THE MAXIMUM LIGHT LEVELS LISTED IN THE DAYLIGHT ZONES UNTIL LIGHT FIXTURES ARE EITHER TURNED 'ON' TO 100% LIGHT OUTPUT OR 'OFF'. DAYLIGHT CONTROLS ARE TO BE PROGRAMMED SUCH THAT MANUAL OVERRIDE CAPABILITIES WILL NOT BE PERMITTED OTHER THAN A REDUCTION OF LIGHT OUTPUT FROM THE LEVEL ESTABLISHED BY THE DAYLIGHT RESPONSE CONTROLS. FOR EXTERIOR LIGHTING, PHOTOCELLS SHALL BE PROGRAMMED TO AUTOMATICALLY TURN LUMINAIRES 'ON' TO 100% LIGHT OUTPUT AT DUSK, AND AUTOMATICALLY TURN LUMINAIRES 'OFF' AT DAWN. TIMECLOCK T1 BUSINESS + EVENING AFTER HOURS PHOTOCELL CONTROLS LUMINAIRES DURING THIS TIME. AUTOMATICALLY TURN LUMINAIRES'OFF.' LOCAL CONTROLS L1 TURN LUMINAIRES'ON' TO 100% LIGHT OUTPUT (UNLESS OTHERWISE NOTED) AND TURN LUMINAIRES'OFF'. SCENE CONTROL LUMINAIRES IN THIS SPACE HAVE SET SCENES. VERIFY ALL SCENE SETTINGS WITH OWNER PRIOR TO PROGRAMMING. TIMECLOCK HOURS SCHEDULE 1 DAY OF WEEK BUSINESS HOURS EVENING HOURS AFTER HOURS MONDAY - FRIDAY 7:00 AM - 6:59 PM 7:00 PM - 10:59 PM 11:00 PM - 6:59 AM SATURDAY - SUNDAY 8:00 AM - 3:39 PM 4:00 PM - 11:59 PM 12:00 AM - 7:59 AM TIMECLOCK HOURS SCHEDULE NOTES 1. VERIFY ALL TIMECLOCK SCHEDULES AND SCENE SETTINGS WITH OWNER PRIOR TO PROGRAMMING. LOAD CLASSIFICATIONS AS LISTED IN THE LOAD SUMMARY ON PANELBOARD SCHEDULES CLASSIFICATION DESCRIPTION CONTINUOUS LOADS WHICH ARE LIKELY TO RUN CONTINUOUSLY FOR OVER 3 HOURS LIGHTING 125% MOTOR 125% OF LARGEST MOTOR, PLUS 100% OF ALL OTHER MOTORS NON -CONTINUOUS 100% RECEPTACLE 100% OF FIRST 10kVA, PLUS 50% OF ALL LOAD ABOVE 10kVA (NEC 220.44) EXAMPLES HEAT TRACE INTERIOR LIGHTING EXTERIOR LIGHTING PUMPS FANS CONVENIENCE RECEPTACLES CODES 2021 INTERNATIONAL BUILDING CODE - WAC 51-50 2023 NATIONAL ELECTRICAL CODE (NFPA 70) 2021 INTERNATIONAL EXISTING BUILDING CODE - WAC 51-50-4800 2021 WASHINGTON STATE ENERGY CODE (WSEC) ENERGY CODE EXISTING LIGHTING CONTROLS TO REMAIN. CONTROLS FOR ALL NEW EXTERIOR FIXTURES SHALL MEET WASHINGTON STATE ENERGY CODE REQUIREMENTS FOR EXTERIOR LIGHTING POWER ALLOWANCES AND CONTROLS: - PHOTOCELL FOR AUTOMATIC SHUTOFF WHEN DAYLIGHT IS PRESENT - TIMECLOCK PROGRAMMED FOR BUSINESS HOURS, AFTER HOURS, AND EVENING. PER WSEC FOR EXISTING BUILDINGS (C503.6.1) "ALTERATIONS THAT REPLACE 20 PERCENT OR MORE OF THE TOTAL INSTALLED WATTAGE OF EXTERIOR LUMINAIRES SHALL COMPLY WITH SECTIONS WITH SECTIONS C405.4 and C405.5. WHERE ... LESS THAN 20 PERCENT OF THE INSTALLED EXTERIOR WATTAGE IS REPLACED, THE INSTALLED LIGHTING WATTAGE SHALL BE MAINTAINED OR REDUCED." FINAL LOAD CALCULATIONS INDICATE TOTAL ADDED FIXTURE WATTAGE IS LESS THAN 20 PERCENT OF THE TOTAL SITE LIGHTING POWER, AND REDUCES THE TOTAL SITE LIGHTING POWER: - EXISTING EXTERIOR LIGHTING POWER (PRIOR TO ALTERATION): 7160 VA - PROPOSED NEW EXTERIOR LIGHTING ADDITION: 1419 VA (19.8%) - TOTAL PROPOSED NEW EXTERIOR LIGHTING POWER: 3319 VA SITE EXTERIOR LIGHTING ZONE: ZONE 2 PIAZZA LIGHTING DESIGN CRITERIA NORMAL LIGHTING: CRITERIA COORDINATED WITH ARCHITECT ON 11/22/2024. SPACE E (AVG HORIZONTAL ILLUMINATION AT FLOOR) PIAZZA 2 FC LOGAN ST CATENARY 3.8 FC EGRESS AND EMERGENCY LIGHTING: EXISTING INSTALLATION DOES NOT INCLUDE ANY BACKUP POWER FOR SITE LIGHTING. PIAZZA LIGHTING FIXTURE SCHEDULE FIXTURE LUMEN NUMBERED DESCRIPTION VOLTAGE LOAD LAMP COLOR MOUNTING MANUFACTURER MODEL TYPE OUTPUT - NOTES 1 (E) A2 DOUBLE HEAD POLE MOUNTED LIGHT (12') 240 V 200 W METAL POLE MOUNTED HALIDE - 1 (E) A3 DOUBLE HEAD POLE MOUNTED LIGHT (16') 240 V 200 W METAL POLE MOUNTED LINEAR LIGHT TUBE 120 V 300 W HALIDE METAL RECESSED - 1 (E) C - - HALIDE (N) F1 MAST POLE MOUNTED FIXTURE 120 V 39 W LED 4500 3000K POLE MOUNTED SELUX OLIVIO GRANDE 2 (N) F1A MAST POLE MOUNTED PROJECTOR 120 V 49 W LED - 6500K POLE MOUNTED SELUX OLIVIO GRANDE GOBO PROJECTOR 2 (N) F2 CATENARY FIXTURE 240 V 43 W LED 3645 3000k CATENARY HESS PEN380X 30K DIM UNV T5 3 NUMBERED NOTES: 1. EXISTING LIGHT FIXTURE DATA BASED ON PIAZZA AS-BUILTS DATED 11/7/2000. 2. FIXTURES MOUNTED ON 18' POLE. EACH POLE HAS (3) FIXTURE HEADS + (2) PROJECTOR HEADS. 3. 240V SINGLE PHASE CONNECTION REQUIRED FOR POWER FROM UTILITY SERVICE CABINET. PROVIDE CIRCUITS IN SCHEDULE 80 PVC, 2" MINIMUM, PER CITY OF RENTON. COORDINATE ALL CIRCUITING AND INSTALLATION REQUIREMENTS WITH CITY OF RENTON AND WORLD CUP LEGACY SQUARE PROJECT DESIGNERS. UP SURVEYED: SCALE: VERTICAL: NAVD 1988 DESIGNED: NTS HORIZONTAL: NAD 1983/1991 1Arup191 US, Inc. Call 811 DRAWN: 1191 Second Avenue Suite 400 � oNE INCH DATU M Seattle A 981258 F + 1 206 749 0665 • two business days IF NOT L SC LE CHECKED: before you digINCH N O. REVISION BY DATE I AP P R I APPROVED: SCALE ACCORDINGLY q 0 CITY OF RENTON Planning/Building/Public Works Dept. T-433403 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING % �IL TRANSPORTATION OPERATION msippo 08/13/2025 CBarnes 08/15/2025 RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT ELECTRICAL - DESIGN CRITERIA AND LOAD CALCULATIONS - PIAZZA 7 / 16 / 2025 PAGE DRAWING NO: E0.03 SHEET: 5OF: 4 61 ARUP Arup US, Inc. 1191 Second Avenue Suite 400 Seattle WA 98101 T +1 206 493 2258 F + 1 206 749 0665 • Call 811 • a two business days before you dig N0. N ELECTRICAL SITE PLAN m SCALE:3/32"=1'-0" (1) SURVEYED: DESIGNED: DRAWN: CHECKED: REVISION I BY I DATE I APPR I APPROVED: SCALE: 1 /1 611=1 1-011 ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM CITY OF RENTON Planning/Building/Public Works Dept SHEET NOTES A. DEMOLITION NOTES FOR INTERIOR BUILDING SPACES NOT INCLUDED ON THIS SHEET. REFERENCE MARKET SHEETS E2.00 AND E3.00 SERIES FOR INTERIOR BUILDING DEMOLITION NOTES. KEYED NOTES 1❑ RETAIN EXISTING CONDUIT TO EXTEND TO NEW RECEPTACLE LOCATION SHOWN ON SHEET E1.00P. COORDINATE EXACT LOCATION WITH LANDSCAPE ARCHITECT. ❑2 EXISTING WATER FEATURE, INCLUDING FOUNTAIN PUMP AND FOUNTAIN LIGHTS, TO BE DEMOLISHED. T-433405 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING msippo 08/13/2025 RENTON MARKET & PIAZZA CIVIL CONSTRUCTION PERMIT ELECTRICAL - DEMO SITE PLAN - PIAZZA 7 / 16 / 2025 PAGE DRAWING NO: ED1.00 SHEET56 OF: 61 SHEET NOTES Add standard details 119,120,124,139 and J013 to plan set. (N) CATENARY LIGHT FIXTURES, TYPE F2 (TYP OF 8) (N) POLES FOR CATENARY LIGHTS, RECEPTACLES, AND COMMS (TYP OF 6) A. ALL SITE POWER AND LIGHTING IS POWERED VIA EXISTING 240/120V PANELS E1 AND E2, LOCATED ON THE NORTH WALL OF THE MAIN ELECTRICAL ROOM. B. EXISTING CONDUIT RETAINED FROM THE DEMOLITION OF SITE POWER AND LIGHTING TO BE EXTENDED WHENEVER POSSIBLE TO NEW RECEPTACLES AND LIGHT FIXTURES KEYED NOTES 1❑ PROVIDE (2) 1" CONDUIT FOR LOW VOLTAGE EQUIPMENT TO EACH POLE �2 EACH MAST POLE HAS (5) LIGHT FIXTURE HEADS AND (1) GFCI DUPLEX RECEPTACLE. EACH POLE RECEIVES (2) CIRCUITS IN (2) 3/4" CONDUIT. EXISTING CONDUIT TO BE EXTENDED WHERE POSSIBLE. �3 RECEPTACLE INTEGRAL TO MAST POLE, AND IS PROVIDED BY OTHERS. ® MOUNT NEMA-3R ENCLOSURE TO SIDE OF STAGE. ENCLOSURE SIZED TO CONTAIN ALL (3) RECEPTACLES. EXACT LOCATION TO BE CONFIRMED BY ARCHITECT. �5 PROVIDE NEW RECEPTACLE IN LANDSCAPING. EXTEND EXISTING CONDUIT FROM DEMOLISHED RECEPTACLE TO NEW RECEPTACLE LOCATION. STUB CONDUIT UP INTO CAST METAL BOX WITH WHILE -IN -USE COVER. © EXTEND CONDUIT UNDERGROUND TO NEW MAST LIGHT POLE. �7 PROVIDE NEW RECEPTACLE IN LANDSCAPING. EXTEND EXISTING CONDUIT FROM DEMOLISHED LIGHT POLE TO NEW RECEPTACLE LOCATION. STUB CONDUIT UP INTO CAST METAL BOX WITH WHILE -IN -USE COVER. ® MANUAL LIGHTING CONTROLS FOR PIAZZA LIGHTING. COORDINATE FINAL LOCATION WITH BUILDING ARCHITECT. �9 PROVIDE SWITCH FOR SITE RECEPTACLES. COORDINATE LOCATION AT EDGE OF PLANTER WHERE FORMER FOUNTAIN CONTROLS BOX IS LOCATED. 10 ROUTE CONDUIT SO THAT IT DOES NOT ENCROACH ON EXISTING TREE CRITICAL ROOT ZONES. REFER TO ARBORIST REPORT. 11 DEDICATED RECEPTACLE FOR HOLIDAY TREE LIGHTING. 12 FINAL CIRCUITING REQUIREMENTS AND CIRCUIT ROUTING TO BE COORDINATED WITH WORLD CUP LEGACY SQUARE DESIGNERS AND CITY OF RENTON. "#" REPRESENTS FUTURE CIRCUIT NUMBER, TO BE COORDINATED. Time clock for catenary lights shall be attached to service cabinet and maintained by Transportation Maintenance. T-433406 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING A' msippo 08/13/2025 N ELECTRICAL SITE PLAN SCALE: 1" = 20'-0" U SURVEYED: SCALE: DATE: / 16 / 2025 1 =25 -0 VERTICAL: NAVD 1988 j;ej CITY OF RENTON MARKET &PIAZZA 11 1 11 HORIZONTAL: NAD 1953/1991 DESIGNED: CIVIL CONSTRUCTION PERMIT FIELDBOOK: Arup US, Inc. 811 DRAWN: RENTON PAGE: IsCall DRAWING NO: Seat Second Avenue Suite 400 ONE INCH DATUM ELECTRICAL - SITE POWER PLAN- rnSeattle WA 98101 two business days CHECKED: AT FULL SCALE r � . 00 T+1 2064932258 F + 1 2067490665 y IF NOT ONE INCH Planning/Building/Public Works Dept. 1 before you dig NO. REVISION BY DATE APPR PIAZZA APPROVED: SCALE ACCORDINGLY F HEET57 OF: 61