HomeMy WebLinkAboutAPPROVED_C25001104_RSD Transportation_DC1Pa
r
k
A
v
e
N
o
r
t
h
North 5th Street
Ga
r
d
e
n
A
v
e
N
o
r
t
h
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
SD
SD
SD
SD
SD
SD
SD
E
E
E
E
E
E
E
E
E
E
E
E
CO
M
CO
M
CO
M
CO
M
CO
M
CO
M
CO
M
CO
M
CO
M
CO
M
CO
M
CO
M
CR E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E E E E E EEEEEEEEEE E
CA =ONING
PARCEL
PROPOSED
PAR.ING LOT
E;PANSION
E;ISTING PAR.ING LOT
DRIVEWA< CUR% CUT
GATED
E;ISTING SECURIT< GATE
NO PU%LIC ACCESS
%E<OND THIS POINT
APPRO;IMATE
PROPERT< LINE
TO %E SURVE<ED
E;ISTING STA))
AND )LEET VEHICLE
PAR.ING LOT
E;ISTING %US
PAR.ING LOT
IL =ONING
PARCEL
IL =ONING
PARCEL
IL =ONING
PARCEL
NEW LIGHT POLE
PER ELEC
L PLANS
CA =ONING
PARCEL
SD A C% T<PE P
PRIVATE
RIM
IE OUTNE
SEE DETAIL T<P
SD A C% T<PE P
PRIVATE
RIM
IE INSW
IE INE
IE OUTN
SD A C% T<PE P
PRIVATE
RIM
IE OUTW
SD A C% T<PE II
PRIVATE
CONTECH CDSC
RIM
IE INW
IE OUTE
SEE DETAIL
SD A )ILTERRA
PRIVATE
RIM
IE INW
IE OUTNE
SEE DETAIL
L)
SD #
PRIVATE
L
)
SD
#
P
R
I
V
A
T
E
L
)
SD
#
P
R
I
V
A
T
E
L)
SD #
PRIVATE
L)
SD #
PRIVATE
CONNECT TO E;
CATCH %ASIN
IE
PRIVATE
UTILIT< ;ING
TOP SS
%OT C%
C
C
E;ISTING VISITOR
PAR.ING LOT
EV CHARGING
STATION POWER POC
PER ELEC
L PLANS
EV READ< CHARGING
STATIONS PER
ELEC
L PLANS
EV IN)RASTRUCTURE TO %E
PROVIDED )OR )UTURE EV
CHARGING STATIONS PER
ELEC
L PLANS T<P UON
UTILIT< ;ING
NEW SD IE
TOP SS
INSTALL ETHA)OAM PAD
)OR PIPE CLEARANCE
LESS THAN
SEE DETAIL
C
E; LIGHT POLE E; LIGHT POLE
C
SD A C% T<PE I
PRIVATE
RIM
IE INS
IE OUTE
L) SD #
PRIVATE
PROTECT
E; PIV
PROTECT
E; )DC
PROTECT E;
DDCVA VAULT
E;ISTING
%UILDING
43667
NSTATE OF WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G I N EER
O
S
B
O
CAJA.DLAREJ
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
4
3
C2
5
0
0
1
1
0
4
LU
A
2
4
-
0
0
0
3
7
6
PR
2
4
-
0
0
0
0
7
9
g. 8-1-1
Call before you
D
or 1-800-424-5555
UNDERGROUND
SERVICE (USA)
R
SCALE 1"=20'
RSD TRANSPORTATION EXPANSION
STORM DRAINAGE AND UTILITY PLAN
SE 1/4 SECTION 08, T. 23 N., R. 5 E., W.M.
LEGENDLEGEND
NOTE:
FOR CATCH BASINS TO BE ADJUSTED (RAISED)
TO FINISH GRADE WHERE INDICATED ON PLANS,
SHIMS ARE NOT ALLOWED PER CITY OF RENTON;
CONTRACTOR SHALL USE CONCRETE COLLARS
R-434309
FOR TYPICAL TRENCH AND BACKFILL
FOR STORM PIPING, SEE DETAIL 7/C410.
FOR CITY OF RENTON SURFACE WATER
STANDARD PLAN NOTES, SEE SHEET C001
NOTE:
DETENTION NOT REQUIRED BECAUSE
STORMWATER IS COLLECTED ON-SITE THEN
CONNECTED TO EXISTING PIPED CONVEYANCE
SYSTEM IN N 5TH ST. STORMWATER IS THEN
CONVEYED WEST ALONG N 5TH ST TO BURNETT
AVE N, THEN NORTH TO N 6TH ST, THEN WEST
ALONG N 6TH ST UNTIL STORMWATER OUTFALLS
INTO THE CEDAR RIVER, WHICH FLOWS NORTH
AND DRAINS INTO LAKE WASHINGTON.
PROPERT< LINE
STORM DRAINAGE PIPE SD
)H)DCPIVVALVE
WATER VAULTMETER
)H )DC PIV WV
WATER LINE W
C% T<PE C% T<PE
AREA DRAINSDCO
LANDSCAPE AREAS SHALL HAVE SOILS
AMENDED, SEE DETAIL 7/C411.
NOTE:
SEE ELECTRICAL PLANS FOR ELECTRIC VEHICLE
(EV) PARKING SPACES AND CHARGING
STATIONS VAULTS, CONDUITS,
INFRASTRUCTURE, AND POWER REQUIREMENTS,
INCLUDING POWER POINT OF CONNECTION.
SEE SHEET C420 FOR STORM
DRAINAGE PROFILES
MATCHLINE - SEE ABOVE RIGHT
MATCHLINE - SEE BELOW LEFT
ACCESSI%LE EV READ<
CHARGING STATION PER
ELEC
L PLANS