HomeMy WebLinkAboutCD-4326LEGAL DESCRIPTION
HAZEN HIGH SCHOOL
MODERNIZATION
IN THE NW 1/4 OF SECTION 10 & THE NE 1/4 OF SECTION 10, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M.
GENERAL NOTES
SITE IMPROVEMENTS - PERMIT SET
PROJECT NOTES
VICINITY MAP
HAZEN HIGH SCHOOL MODERNIZATION
COVER SHEET
TE
D
-
4
0
-
4
3
2
6
R-432601
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
1.THE CONTRACTOR SHALL TAKE REASONABLE PRECAUTIONS AND EXERCISE SOUND
ENGINEERING AND CONSTRUCTION PRACTICES IN CONDUCTING THE WORK. THE
CONTRACTOR SHALL PROTECT EXISTING PUBLIC AND PRIVATE UTILITIES FROM DAMAGE
DURING CONSTRUCTION. IF EXISTING UTILITIES ARE DAMAGED, THE CONTRACTOR SHALL
IMMEDIATELY NOTIFY THE UTILITY PURVEYOR, OWNER AND THE ENGINEER. THE
CONTRACTOR SHALL RESTORE THE UTILITY TO ITS EXISTING CONDITION. (WSDOT SEC.
1-07.17 APWA SUPPLEMENT). THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND
THE METHODS OF CONSTRUCTION FOR WORK SHOWN ON THESE PLANS.
2.ALL EXCAVATION, TRENCHING, SUBGRADE PREPARATION, FILL PLACEMENT, AND ALL
SOIL WORK IN GENERAL SHALL BE CONDUCTED IN COMPLIANCE WITH THE CITY OF
RENTON STANDARDS.
3.CONTRACTOR SHALL BE RESPONSIBLE FOR HIRING A PROFESSIONAL LAND SURVEYOR
TO REFERENCE EXISTING MONUMENTS ON OR ADJOINING ESTABLISHED SAID POINTS AT
PROJECT COMPLETION. THIS REESTABLISHMENT SHALL BE DOCUMENTED BY RECORD
OF SURVEY PREVIOUS TO DEMOLITION OR CONSTRUCTION AND TO RECORNER RECORD
AS DESCRIBED IN W.A.C. 332-120.
4.CONTRACTOR SHALL MAINTAIN A 5 FOOT MINIMUM HORIZONTAL CLEARANCE FROM THE
WATER MAIN AND OTHER UTILITIES (i.e. GAS, CABLE, POWER, ETC.). IF SAID CLEARANCE
CANNOT BE MAINTAINED, CONTACT ENGINEER FOR APPROVAL AND RECORD EXACT
MEASUREMENTS OF THE UTILITY LINES ON THE AS-BUILT DRAWINGS. A 10 FOOT
MINIMUM HORIZONTAL CLEARANCE MUST BE MAINTAINED BETWEEN WATER MAIN AND
SANITARY SEWER.
5.SCHEDULE WITH CITY AND OWNER (96 HOURS MINIMUM NOTICE FOR WATER MAIN SHUT
DOWN ON THE SCHOOL SITE). INSTALL CITY STANDARD TESTING CONNECTION ON NEW
WATER MAIN FOLLOWING COMPLETION OF NEW WATER SYSTEM CONSTRUCTION,
TESTING, AND ACCEPTANCE BY THE CITY, REMOVE TESTING CONNECTION AND INSTALL
SEGMENT OF DI PIPE, LENGTH TO SUIT, WITH TWO LONG PATTERN SLEEVES.
INSTALLATION AND CONNECTION TO EXISTING WATER SYSTEM SHALL BE WITH 100%
CITY INSPECTION.
6.UNDERGROUND UTILITIES ARE SHOWN IN THE APPROXIMATE LOCATION. THERE IS NOT A
GUARANTEE THAT ALL UTILITY LINES ARE SHOWN OR THAT THE LOCATION, SIZE, AND
MATERIAL IS ACCURATE. THE CONTRACTOR SHALL UNCOVER ALL INDICATED PIPING
WHERE CROSSINGS, INTERFERENCE'S OR CONNECTIONS OCCUR PRIOR TO TRENCHING
OR EXCAVATION FOR ANY PIPE OR STRUCTURES, TO DETERMINE ACTUAL LOCATIONS,
SIZE AND MATERIAL. THE CONTRACTOR SHALL MAKE THE APPROPRIATE PROVISION FOR
PROTECTION OF SAID FACILITIES. THE CONTRACTOR SHALL NOTIFY ONE CALL AT 811
AND ARRANGE FOR PUBLIC AND PRIVATE FIELD LOCATION OF EXISTING FACILITIES
BEFORE CONSTRUCTION.
7.SCHEDULE WITH CITY (48 HOURS MINIMUM NOTICE) FOR WATER METER SHUTOFF AND
TO RETIRE METERS.
1.ALL WORK SHALL CONFORM TO THE DESIGN AND CONSTRUCTION STANDARDS AND SPECIFICATIONS FOR
CITY OF RENTON. A COPY OF THESE DOCUMENTS SHALL BE ON SITE DURING CONSTRUCTION.
2.A COPY OF THE APPROVED PLANS MUST BE ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
3.ERRORS AND OMISSIONS ON THE PERMITTED PLANS MUST BE CORRECTED BY THE ENGINEER AND
APPROVED BY THE CITY OF RENTON.
4.ALL PERMITS REQUIRED FOR WORK WITHIN THE PUBLIC RIGHT OF WAY MUST BE OBTAINED BY THE
CONTRACTOR PRIOR TO THE START OF CONSTRUCTION.
5.PRIOR TO THE START OF CONSTRUCTION WITHIN THE RIGHT OF WAY, THE CONTRACTOR SHALL
SCHEDULE AND ATTEND A PRECONSTRUCTION MEETING WITH THE CITY OF RENTON. THE OWNER,
RECORD ENGINEER, CONTRACTOR AND DESIGNATED SUBCONTRACTORS SHALL BE PRESENT AT THE
PRECONSTRUCTION MEETING.
6.EXISTING PAVED SURFACES INCLUDING ROADWAYS, SIDEWALKS, AND CURBS THAT ARE DAMAGED BY
NEW CONSTRUCTION SHALL BE REPAIRED AS REQUIRED BY CITY OF RENTON AND THEIR INSPECTORS.
7.ALL DAMAGE TO CITY INFRASTRUCTURE CAUSED BY THE CONSTRUCTION SHALL BE REPAIRED AS
REQUIRED BY THE CITY OF RENTON.
8.THE APPROVED PLANS SHOW THE APPROXIMATE AREA OF PAVEMENT RESTORATION BASED ON THE
DEPTH OF UTILITY CUTS AND/OR THE AREA OF CURB AND/OR PAVEMENT TO BE REMOVED AND
REPLACED. THE ACTUAL LIMITS OF THE PAVEMENT RESTORATION SHALL BE DETERMINED IN THE FIELD
BY THE CITY OF RENTON INSPECTORS PRIOR TO THE PAVEMENT RESTORATION.
9.SURVEYING AND STAKING OF ALL IMPROVEMENTS IN THE PUBLIC RIGHT OF WAY SHALL BE COMPLETED
PRIOR TO CONSTRUCTION. SURVEY CUT SHEETS MUST BE COORDINATED WITH CITY OF RENTON
INSPECTORS AT LEAST 5 DAYS PRIOR TO CONSTRUCTION.
10.IF AN EXISTING CURB IS TO BE REMOVED AND REPLACED IN THE SAME LOCATION THE CONTRACTOR
SHALL PROVIDE THE CITY OF RENTON INSPECTOR A PLAN WITH EXISTING FLOW LINE AND TOP OF CURB
ELEVATIONS IDENTIFIED. PERMITTEE TO STAKE THE LOCATION OF THE EXISTING CURB PRIOR TO
DEMOLITION.
11.THE CONTRACTOR SHALL BE RESPONSIBLE FOR REFERENCING AND REPLACING ALL MONUMENTS THAT
MAY BE DISTURBED, DESTROYED OR REMOVED BY THE PROJECT AND SHALL FILE AN APPLICATION FOR
PERMIT TO REMOVE OR DESTROY A SURVEY MONUMENT WITH THE WASHINGTON STATE DEPARTMENT
OF NATURAL RESOURCES, PURSUANT TO RCW 58.24.040(8).
12.THE CONTRACTOR SHALL SUBMIT ALL APPLICABLE DOCUMENTS AS REQUIRED PER THE CITY OF RENTON
DESIGN AND CONSTRUCTION STANDARDS AND SPECIFICATIONS PRIOR TO CONSTRUCTION. A MATERIAL
SOURCE FORM FOR ALL MATERIALS TO BE PLACED IN THE RIGHT OF WAY AND MIX DESIGNS FOR ALL
ASPHALT, CONCRETE AND AGGREGATES TO BE PLACED IN THE RIGHT OF WAY MUST BE SUBMITTED TO
THE CITY OF RENTON FOR REVIEW AND APPROVAL PRIOR TO BEGINNING CONSTRUCTION.
13.THE CONTRACTOR SHALL NOTIFY THE KING COUNTY FIRE PROTECTION DISTRICT NO. 40 AT LEAST
TWENTY-FOUR (24) HOURS IN ADVANCE OF ALL WATER SERVICE INTERRUPTIONS, HYDRANT SHUTOFFS,
AND STREET CLOSURES OR OTHER ACCESS BLOCKAGE. THE CONTRACTOR SHALL ALSO NOTIFY THE FIRE
DISTRICT OF ALL NEW, RELOCATED, OR ELIMINATED HYDRANTS RESULTING FROM THIS WORK.
14.THE CONTRACTOR SHALL LOCATE AND PROTECT ALL CASTINGS AND UTILITIES DURING CONSTRUCTION.
15.THE CONTRACTOR SHALL CONTACT THE UNDERGROUND UTILITIES LOCATOR SERVICE (811) AT LEAST 48
HOURS PRIOR TO CONSTRUCTION.
16.THE CONTRACTOR SHALL CONTACT A PRIVATE UTILITY LOCATOR FOR ALL ON-SITE WORK ON THE PROJECT
AND ADJACENT PRIVATE PROPERTIES, AT LEAST 48 HOURS PRIOR TO CONSTRUCTION.
17.IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE ACCURACY OF ALL UTILITY
LOCATIONS SHOWN AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN WHICH
MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THIS MAY INCLUDE, BUT IS NOT LIMITED TO,
POTHOLE EXCAVATION AND OTHER MEANS AND METHODS.
18.THE CONTRACTOR SHALL ADJUST ALL EXISTING AND PROPOSED MANHOLE RIMS, DRAINAGE STRUCTURE
LIDS, VALVE BOXES, AND UTILITY ACCESS STRUCTURES TO FINISH GRADE WITHIN AREAS AFFECTED BY
THE PROPOSED IMPROVEMENTS. THIS INCLUDES AS REQUIRED DURING PHASING TO ACCOMMODATE
INTERIM AND FINAL GRADING
19.UTILITY SERVICE CONNECTIONS SHOWN ON THE PLANS REQUIRE SEPARATE PERMITS FROM THE CEDAR
RIVER WATER AND SEWER DISTRICT AND ARE TO BE OBTAINED BY THE CONTRACTOR, AND ARE NOT
COORDINATED BY OR OBTAINED BY KING COUUNTY DPER.
20.THE CONTRACTOR SHALL PROVIDE FOR ALL TESTING AS REQUIRED BY THE CITY OF RENTON INSPECTOR.
21.BACKFILL MATERIAL USED IN PUBLIC RIGHT-OF-WAY SHALL MEET STANDARD SPECIFICATIONS AND
SHALL BE APPROVED BY THE CITY OF RENTON.
22.INSPECTION AND ACCEPTANCE OF ALL WORK IN THE PUBLIC RIGHT-OF-WAY SHALL BE DONE BY
REPRESENTATIVES OF CITY OF RENTON. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO
COORDINATE AND SCHEDULE APPROPRIATE INSPECTIONS ALLOWING FOR PROPER ADVANCE NOTICE.
THE CITY OF RENTON INSPECTOR MAY REQUIRE REMOVAL AND RECONSTRUCTION OF ANY ITEMS PLACED
IN THE RIGHT OF WAY THAT DO NOT MEET COUNTY STANDARDS OR THAT WERE CONSTRUCTED WITHOUT
APPROPRIATE INSPECTIONS.
23.THE CONTRACTOR SHALL PROVIDE AND MAINTAIN TEMPORARY EROSION CONTROL AND SEDIMENTATION
COLLECTION FACILITIES TO ENSURE THAT SEDIMENT-LADEN WATER DOES NOT ENTER THE NATURAL OR
PUBLIC DRAINAGE SYSTEM. AS CONSTRUCTION PROGRESSES AND UNEXPECTED (SEASONAL)
CONDITIONS DICTATE, ADDITIONAL CONTROL FACILITIES MAY BE REQUIRED. DURING THE COURSE OF
CONSTRUCTION IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE CONTRACTOR TO ADDRESS
ANY NEW CONDITIONS THAT MAY BE CREATED BY THE CONTRACTORS ACTIVITIES AND TO PROVIDE
ADDITIONAL FACILITIES THAT MAY BE NEEDED TO PROTECT ADJACENT PROPERTIES.
24.THE CONTRACTOR SHALL KEEP ALL PAVED SURFACES IN THE RIGHT OF WAY CLEAN BY SWEEPING. USE
VACUUM TYPE SWEEPER
25.CARE SHALL BE EXERCISED WHEN EXCAVATING NEAR EXISTING CHARGED WATER MAINS.
26.ALL UTILITY CROSSINGS NOTED AS "ASSUMED" ARE UNKNOWN DURING DESIGN. THE UNKNOWN
ELEVATIONS AND LOCATIONS MUST BE VERIFIED PRIOR TO ANY UTILITY CONSTRUCTION. ELEVATIONS
THAT DIFFER FROM ASSUMED ELEVATION SHALL BE FORWARDED TO THE CIVIL ENGINEER FOR REVIEW.
PARCEL A:
THE EAST 200 FEET OF THE NORTH 170 FEET OF THE FOLLOWING DESCRIBED TRACT:
THE NORTH HALF OF THE NORTHWEST QUARTER OF THE NORTHWEST QUARTER OF THE
NORTHEAST QUARTER OF SECTION 10, TOWNSHIP 23 NORTH, RANGE 5 EAST,
WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON;
EXCEPT THE NORTH 30 FEET AND THE EAST 30 FEET THEREOF.
PARCEL B:
THE SOUTH HALF OF THE NORTHWEST QUARTER OF THE NORTHWEST QUARTER OF THE
NORTHEAST QUARTER OF SECTION 10, TOWNSHIP 23 NORTH, RANGE 5 EAST,
WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON;
EXCEPT THE NORTH 15 FEET; ALSO
EXCEPT THE SOUTH 132 FEET OF THE EAST 330 FEET THEREOF; ALSO
EXCEPT THAT PORTION THEREOF LYING WITHIN THE EAST 30 FEET OF SAID SUBDIVISION,
CONVEYED TO KING COUNTY FOR ROAD BY DEED RECORDED UNDER RECORDING NO.
3262476.
PARCEL C:
LOT 2 OF CITY OF RENTON LOT LINE ADJUSTMENT NO. LUA-00-148-LLA, RECORDED
UNDER RECORDING NO. 20010529900002, IN KING COUNTY, WASHINGTON.
PARCEL D:
THE NORTH HALF OF THE NORTHWEST QUARTER OF THE NORTHWEST QUARTER OF THE
NORTHEAST QUARTER OF SECTION 10, TOWNSHIP 23 NORTH, RANGE 5 EAST,
WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON;
EXCEPT THE NORTH 30 FEET AND THE EAST 30 FEET FOR ROAD; ALSO
EXCEPT THE EAST 200 FEET OF THE NORTH 170 FEET OF THE REMAINDER;
TOGETHER WITH THE NORTH 15 FEET OF THE SOUTH HALF OF THE NORTHWEST
QUARTER OF THE NORTHWEST QUARTER OF THE NORTHEAST QUARTER OF SECTION 10,
TOWNSHIP 23 NORTH, RANGE 5 EAST, WILLAMETTE MERIDIAN, IN KING COUNTY,
WASHINGTON;
EXCEPT THE EAST 30 FEET THEREOF CONVEYED TO KING COUNTY FOR ROAD PURPOSES
BY DEED RECORDED UNDER RECORDING NO. 3262476.
PARCEL E:
THE WEST 150 FEET OF THE SOUTH 132 FEET OF THE EAST 330 FEET OF THE
NORTHWEST QUARTER OF THE NORTHWEST QUARTER OF THE NORTHEAST QUARTER OF
SECTION 10, TOWNSHIP 23 NORTH, RANGE 5 EAST, WILLAMETTE MERIDIAN, IN KING
COUNTY, WASHINGTON.
PARCEL F:
THE EAST 180 FEET OF THE SOUTH 132 FEET OF THE EAST 330 FEET OF THE
NORTHWEST QUARTER OF THE NORTHWEST QUARTER OF THE NORTHEAST QUARTER OF
SECTION 10, TOWNSHIP 23 NORTH, RANGE 5 EAST, WILLAMETTE MERIDIAN, IN KING
COUNTY, WASHINGTON;
EXCEPT THE EAST 30 FEET CONVEYED TO KING COUNTY FOR ROAD PURPOSES BY DEED
RECORDED UNDER RECORDING NO. 3262476.
PARCEL G:
THE SOUTH 530 FEET OF TRACT 6, JOSEPH P. MARSHALL TRACTS, ACCORDING TO THE
PLAT THEREOF RECORDED IN VOLUME 38 OF PLATS, PAGE 30, IN KING COUNTY,
WASHINGTON;
PARCEL H:
THE WEST HALF OF THE NORTHEAST QUARTER OF THE NORTHEAST QUARTER OF THE
NORTHWEST QUARTER OF SECTION 10, TOWNSHIP 23 NORTH, RANGE 5 EAST,
WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON;
EXCEPT THE NORTH 275 FEET, THEREOF;
ALSO EXCEPT THAT PORTION LYING WITHIN THE COUNTY ROAD.
PARCEL I:
THE WEST HALF OF THE SOUTH HALF OF THE EAST HALF OF THE EAST HALF OF THE
NORTHEAST QUARTER OF THE NORTHWEST QUARTER OF SECTION 10, TOWNSHIP 23
NORTH, RANGE 5 EAST, WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON;
EXCEPT THAT PORTION LYING WITHIN THE COUNTY ROAD.
OWNER:RENTON SCHOOL DISTRICT
CAPITAL PLANNING & CONSTRUCTION
7812 SOUTH 124TH STREET
SEATTLE, WA 98178
(206) 482-5253 CONTACT: MIKE CATO
MICHAEL.CATO@RENTONSCHOOLS.US
ENGINEER:JACOBSON CONSULTING ENGINEERS
255 S. KING STREET, SUITE 800
SEATTLE, WA 98104
(206) 426-2600 CONTACT: ALAN JACOBSON
ALAN@JACOBSONENGINEERS.COM
LANDSCAPE:
ARCHITECT
FORA LANDSCAPE ARCHITECTS
1430 NE 65TH STREET
SEATTLE, WA 98115
(425)350-3229 CONTACT: NICK HAGAN
NICK@FORA.LAND
NOTE:
1.THE QUANTITIES SHOWN ARE PRELIMINARY ESTIMATES ONLY AND INTENDED FOR
MUNICIPAL PERMITTING AND REVIEW FEES. THE CONTRACTOR SHALL IGNORE THESE
QUANTITIES, THEY ARE EXCLUDED FROM THE BID DOCUMENT INFORMATION. THESE
VOLUMES SHALL NOT BE USED BY THE CONTRACTOR AS A BASIS FOR ANY CONTRACTUAL
INFORMATION. THE CONTRACTOR SHALL PREPARE THEIR OWN EARTHWORK QUANTITIES
BASED ON THE INFORMATION PROVIDED IN THE CONTRACT DOCUMENTS, INCLUDING BUT
NOT LIMITED TO DRAWINGS, SPECIFICATIONS, AND THE GEOTECHNICAL REPORT.
2.INCLUDES APPROXIMATELY 10,268 CY FOR FIELD EXCAVATION (PER TYP FIELD SECTION)
AND ROUGHLY 7,577 CY FOR EXCAVATION OF DETENTION SYSTEMS FOR FIELDS.
3.INCLUDES APPROXIMATELY 1,676 CY FOR BACKFILL FOR DETENTION SYSTEMS FOR FIELDS.
EARTHWORK QUANTITIES
EXCAVATION SEE NOTE 2 14,953 CY
FILL SEE NOTE 3 5,154 CY
TOTAL EARTHWORK 20,107 CY
SITE INFORMATION
DATUM
BASIS OF BEARING
SITE ADDRESS:
1101 HOQUIAM AVENUE NE
RENTON, WA 98059
PARCEL NUMBERS:
102305-9072
102305-9201
102305-9277
102305-9278
HORIZONTAL BENCHMARKS:
OWNER:CITY OF RENTON
ID#1845
DESCRIPTION:PUNCHED 1/2" BRASS ROD IN CASE DOWN 1.65'.
LOCATION:INTERSECTION OF 148TH AVE. S.E. & S.E. 112TH ST.
NORTHING:186170.72'
EASTING:1316637.83'
OWNER:CITY OF RENTON
ID#1849
DESCRIPTION:PUNCHED "X" IN 2" BRASS DISC IN CASE DOWN 0.30'.
LOCATION:INTERSECTION OF FIELD AVE. N.E. & N.E. 8TH ST.
NORTHING:183615.51'
EASTING: 1313987.64'
VERTICAL BENCHMARKS:
SOURCE CITY OF RENTON
ID# 1845
DESCRIPTION: PUNCHED 1/2" BRASS ROD IN CASE DOWN 1.65'.
LOCATION:INTERSECTION OF 148TH AVE. S.E. & S.E. 112TH ST.
ELEVATION: 467.76'
SOURCE CITY OF RENTON
ID#159
DESCRIPTION:PUNCHED 1-3/4" STEEL ROD IN CASE DOWN 0.60'.
LOCATION:INTERSECTION OF N.E. 12TH ST. & UNION AVE. N.E.
ELEVATION:415.95'
HORIZONTAL DATUM:
NAD 83/2011 - (EPOCH 2010)
VERTICAL DATUM:
NAVD 88
ARCHITECT:INTEGRUS ARCHITECTURE
117 S MAIN STREET, SUITE 100
SEATTLE, WA 98104
(206)628-3137 CONTACT: ALEXANDRA FORIN;
AFORIN@INTEGRUSARCH.COM
ZONING:
R8- RESIDENTIAL 8 DU/AC
RMF- RESIDENTIAL MULTI-FAMILY
PARCEL AREAS:
159,429 SF OR 3.66 AC (APN 1023059072)
650,546 SF OR 14.93 AC (APN 1023059201)
110,642 SF OR 2.54 AC (APN 1023059277)
178,596 SF OR 4.10 AC (APN 1023059278)
NOTE:
ALL GROUNDWATER DISCHARGE SHALL MEET
THE REQUIREMENTS OF THE PROJECT’S
COVERAGE UNDER THE NPDES
CONSTRUCTION STORMWATER PERMIT. IF
GROUND WATER CANNOT BE DISCHARGED
THROUGH STORMWATER, CONSTRUCTION
STORMWATER DIRECTED TO THE PUBLIC
SEWER SYSTEM WILL REQUIRE APPROVAL OF
KING COUNTY, A KC INDUSTRIAL WASTE
PERMIT AND RENTON DISCHARGE PERMIT.
Sheet List Table
SHEET 1 OF 76 C000 COVER SHEET
SHEET 2 OF 76 C001 NOTES SHEET
SHEET 3 OF 76 C010 OVERALL SITE PLAN
SHEET 4 OF 76 C101 DEMOLITION AND TESC PLAN
SHEET 5 OF 76 C102 DEMOLITION AND TESC PLAN
SHEET 6 OF 76 C103 DEMOLITION AND TESC PLAN
SHEET 7 OF 76 C104 DEMOLITION AND TESC PLAN
SHEET 8 OF 76 C105 DEMOLITION AND TESC PLAN
SHEET 9 OF 76 C106 DEMOLITION AND TESC PLAN
SHEET 10 OF 76 C107 DEMOLITION AND TESC PLAN
SHEET 11 OF 76 C108 HOQUIAM AVE NE DEMOLITION AND TESC PLAN
SHEET 12 OF 76 C109 NE 10TH ST DEMOLITION AND TESC PLAN
SHEET 13 OF 76 C110 TESC DETAILS
SHEET 14 OF 76 C111 TESC DETAILS
SHEET 15 OF 76 C201 CIVIL SITE PLAN
SHEET 16 OF 76 C202 CIVIL SITE PLAN
SHEET 17 OF 76 C203 CIVIL SITE PLAN
SHEET 18 OF 76 C204 CIVIL SITE PLAN
SHEET 19 OF 76 C205 CIVIL SITE PLAN
SHEET 20 OF 76 C206 CIVIL SITE PLAN
SHEET 21 OF 76 C207 CIVIL SITE PLAN
SHEET 22 OF 76 C208 HOQUIAM AVE NE CIVIL SITE PLAN
SHEET 23 OF 76 C209 NE 10TH ST CIVIL SITE PLAN
SHEET 24 OF 76 C210 HOQUIAM AVE NE STRIPING AND SIGNAGE PLAN
SHEET 25 OF 76 C211 NE 10TH ST STRIPING AND SIGNAGE PLAN
SHEET 26 OF 76 C300 SITE DETAILS
SHEET 27 OF 76 C301 SITE DETAILS
SHEET 28 OF 76 C302 SITE DETAILS
SHEET 29 OF 76 C303 SITE DETAILS
SHEET 30 OF 76 C304 SITE DETAILS
SHEET 31 OF 76 C310 DRAINAGE DETAILS
SHEET 32 OF 76 C311 DRAINAGE DETAILS
SHEET 33 OF 76 C312 DRAINAGE DETAILS
SHEET 34 OF 76 C313 DRAINAGE DETAILS
SHEET 35 OF 76 C314 DRAINAGE DETAILS
SHEET 36 OF 76 C316 DRAINAGE DETAILS
SHEET 37 OF 76 C317 DRAINAGE DETAILS
SHEET 38 OF 76 C318 DRAINAGE DETAILS
SHEET 39 OF 76 C319 UTILITY DETAILS
SHEET 40 OF 76 C320 UTILITY PROFILES AND SECTIONS
SHEET 41 OF 76 C321 DRAINAGE PROFILES
SHEET 42 OF 76 C322 DRAINAGE PROFILES
SHEET 43 OF 76 C330 DETAILED ROW IMPROVEMENTS
SHEET 44 OF 76 C331 DETAILED ROW IMPROVEMENTS
SHEET 45 OF 76 C332 DETAILED ROW IMPROVEMENTS
SHEET 46 OF 76 C333 ROW SECTIONS
SHEET 47 OF 76 C334 NE 10TH ST PROFILE
SHEET 48 OF 76 C335 NE 10TH ST PROFILE
SHEET 49 OF 76 L100 OVERALL LANDSCAPE PLAN
SHEET 50 OF 76 L101 LANDSCAPE PLAN
SHEET 51 OF 76 L102 LANDSCAPE PLAN
SHEET 52 OF 76 L103 LANDSCAPE PLAN
SHEET 53 OF 76 L104 LANDSCAPE PLAN
SHEET 54 OF 76 L105 LANDSCAPE PLAN & LEGEND
SHEET 55 OF 76 L300 OVERALL IRRIGATION PLAN
SHEET 56 OF 76 L301 IRRIGATION PLAN
SHEET 57 OF 76 L302 IRRIGATION PLAN
SHEET 58 OF 76 L303 IRRIGATION PLAN
SHEET 59 OF 76 L304 IRRIGATION SCHEDULE & DETAILS
SHEET 60 OF 76 L305 IRRIGATION DETAILS
SHEET 61 OF 76 L306 IRRIGATION DETAILS
SHEET 62 OF 76 L400 LANDSCAPE DETAILS
SHEET 63 OF 76 L401 LANDSCAPE DETAILS
SHEET 64 OF 76 L500 OVERALL SUBDRAINAGE PLAN
SHEET 65 OF 76 L501 SUBDRAINAGE PLAN
SHEET 66 OF 76 L502 SUBDRAINAGE PLAN
SHEET 67 OF 76 L503 SUBDRAINAGE DETAILS
SHEET 68 OF 76 E001 ELECTRICAL LEGEND
SHEET 69 OF 76 E002 ELECTRICAL ABBREVIATIONS AND NOTES
SHEET 70 OF 76 E101 ELECTRICAL SITE PLAN - STREET LIGHTING N.E.
10TH ST.
SHEET 71 OF 76 E102 ELECTRICAL SITE PLAN - RRFB HOQUIAM AVE.
N.E.
SHEET 72 OF 76 E901 ELECTRICAL DETAILS
SHEET 73 OF 76 E902 ELECTRICAL DETAILS
SHEET 74 OF 76 E903 ELECTRICAL DETAILS
SHEET 75 OF 76 E904 ELECTRICAL DETAILS
SHEET 76 OF 76 E905 ELECTRICAL DETAILS
15,521
20,675
R-432601
& DETAILS
electrical drawings not approved.
see conditions sheets 68-76.
DEVELOPMENT ENGINEERING
msippo 08/07/2025
REGIONAL FIRE AUTHORITY
cthomas 08/07/2025
APPROVED WATER UTILITY
ABDOUL GAFOUR 08/08/2025
amorganroth
08/08/2025
CURRENT PLANNINGSurface Water Enginering
jfarah 08/11/2025
IN THE NW 1/4 OF SECTION 10 & THE NE 1/4 OF SECTION 10, TOWNSHIP 23 NORTH, RANGE 05 EAST, W.M.
HAZEN HIGH SCHOOL MODERNIZATION
NOTES SHEET
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT
CONTROL ( ESC) PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR
OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT.
HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED
FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES.
1.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE- CONSTRUCTION MEETING SHALL BE HELD
AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT' S CONTRACTOR.
2.THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY)
CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE
THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION
STORMWATER GENERAL PERMIT.
3.THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE
FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST- PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC
REQUIREMENTS.
4.THE BOUNDARIES OF THE CLEARING LIMITS, SENSITIVE AREAS AND THEIR BUFFERS, AND AREAS OF VEGETATION
PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN( S) SHALL BE CLEARLY DELINEATED BY FENCING AND
PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (
RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE
BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/
ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION.
5.STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED
FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH
PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK- OUT TO ROAD RIGHT OF WAY
DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE
CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO
PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE.
6.WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF- SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS
ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON- SITE
DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS.
7.WASHOUT AREAS. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/
OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND
ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT
CLEARING AND/ OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON- SITE EROSION HAS PASSED. ALL ESC BMPS
SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL
FOR ON- SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND
REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT.
8.ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED
OF PROPERLY.
9.THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE
CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT
SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE
PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE
APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL
ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND
WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM.
10.APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE
NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR STORMWATER FACILITIES.
11.ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO
THE CITY FOR REVIEW AND APPROVAL.
12.ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS
DURING THE WET SEASON ( OCTOBER 1ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON ( MAY 1ST
THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS ( E.G.,
SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM.
13.WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1ST AND APRIL 30TH,
UNLESS OTHERWISE APPROVED BY THE CITY.
14.ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN
SEVEN ( 7) DAYS.
15.THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN
24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED
BY THE CITY.
16.BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.
30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR
CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP.
ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY
FUNCTIONING CONDITION.
17.AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH
BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH
SEDIMENT- LADEN WATER INTO THE DOWNSTREAM SYSTEM.
18.ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH
THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO
ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE
ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE
PERMANENT FACILITY.
19.AREAS DESIGNATED ON THE PLAN( S) CONTAINING EXISTING STORMWATER FACILITIES OR ON- SITE BMPS ( AMENDED
SOILS, BIORETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO
AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION.
20.PRIOR TO THE BEGINNING OF THE WET SEASON ( OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO
IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS
SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS
TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW.
21.PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT- LADEN
WATER FROM LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE
SYSTEMS, FACILITIES, AND ON- SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL
DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT A
MINIMUM, DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL
DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED
BEFORE OCTOBER 1ST.
22.ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL
NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS- OF- WAY SHALL BE
CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS- OF- WAY SHALL BE
CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE.
CITY OF RENTON EROSION AND SEDIMENT CONTROL (ESC)
STANDARD PLAN NOTES (PER CITY STD. PLAN 268.00)
1.BEFORE ANY CONSTRUCTION ACTIVITY ARRANGE AND ATTEND PRE-CONSTRUCTION
CONFERENCES WITH CITY OF RENTON AND JACOBSON CONSULTING ENGINEERS.
2.COMPLY WITH CONSTRUCTION PHASING REQUIREMENTS IDENTIFIED IN DRAWINGS
AND SPECIFICATIONS.
3.PROVIDE TEMPORARY AND INTERIM MEASURES REQUIRED FOR EXECUTION OF THE
WORK.
4.VERIFY VERTICAL AND HORIZONTAL LOCATIONS OF ALL EXISTING UNDERGROUND
UTILITIES. CONTACT ALL UTILITY COMPANIES OR PROVIDERS THAT MAY BE
AFFECTED BY THE PROPOSED CONSTRUCTION. CALL 811 AND UTILIZE PRIVATE
LOCATING COMPANY ALONG THE ENTIRE WORK AREA.
5.PROVIDE CATCH BASIN PROTECTION AND OTHER APPROPRIATE TESC MEASURES,
INCLUDING STRAW WATTLES, ETC. COORDINATE WITH CITY OF RENTON INSPECTOR.
6.BACKFILL AND COMPACT TRENCH. PATCH AND RESTORE SITE PER PLANS
7.INSTALL ALL NEW PAVING, LANDSCAPING AND SITE STABILIZATION.
8.CONTACT DESIGN ENGINEER AND CITY SO THEY CAN PUNCH LIST THE SITE.
ADDRESS PUNCH LIST ITEMS AS REQUIRED.
CONSTRUCTION SEQUENCE
1.SCHEDULE MAJOR LAND DISTURBING ACTIVITIES DURING THE DRY MONTHS AND ALLOW
TIME BEFORE THE WET SEASON BEGINS TO ADEQUATELY STABILIZE THE DISTURBED
GROUND. CONTRACTOR SHALL MONITOR, REPLACE, AND SUPPLEMENT TESC MEASURES
WITH ADDITIONAL MEASURES DURING WET SEASON TO MITIGATE FOR ANY POTENTIAL FOR
EROSION OR SEDIMENT ON-SITE TO OCCUR AND IMPACT THE RIGHT-OF-WAY OR
NEIGHBORING PROPERTIES (I.E. DOUBLE SILT FENCE, REPLACE CB INSERTS MORE OFTEN,
ETC. CONTRACTOR SHALL UPDATE AND INCLUDE ADDITIONAL MEASURES BEING
IMPLEMENTED DURING THE WET SEASON IN THE CSWPPP THAT WILL BE ON-SITE IN THE
CONSTRUCTION TRAILER.
2.PHASE AND/OR SCHEDULE CONSTRUCTION TO LIMIT THE AMOUNT OF DISTURBED,
UNSTABILIZED SOIL EXPOSED AT ANY ONE TIME. CONTRACTOR SHALL PROVIDE PHASING
AND CONSTRUCTION SCHEDULE TO THE CITY PROJECT MANAGER AND INSPECTOR PRIOR
TO STARTING CONSTRUCTION.
3.FENCE OR FLAG AREAS TO BE PROTECTED OF LEFT UNDISTURBED DURING
CONSTRUCTION, INCLUDING INSTALLATION OF TEMPORARY CONSTRUCTION FENCING AND
TREE PROTECTION MEASURES.
4.STRIP AND CLEAR AND GRUB FIELD SUFFICIENTLY FOR INSTALLATION OF TEMPORARY
EROSION SEDIMENTATION CONTROL (ESC) BMPS.
5.INSTALL TEMPORARY ESC MEASURES INDICATED ON PLANS, INCLUDING BUT NOT LIMITED
TO, SILT FENCE, CATCH BASIN INSERTS, INTERCEPTOR SWALES, CHECK DAMS, SEDIMENT
RETENTION FACILITIES (I.E. SEDIMENT SETTLEMENT TANKS, SEDIMENT TRAPS/PONDS,
ETC.), AND STRAW WATTLES. COORDINATE WITH CITY OF RENTON INSPECTOR.
6.PROVIDE TEMPORARY PEDESTRIAN DETOUR ROUTES, SIGNS, FENCING, ETC. BOTH ON-SITE
AND IN THE PUBLIC RIGHT-OF-WAY
7.BEGIN GRADING AND EXCAVATION FOR FIELD UNDERDRAIN AND IRRIGATION PIPING, AND
FOR PAVEMENT SUBGRADES.
8.TEMPORARILY STABILIZE SITE, THROUGH RE-VEGETATION, HYDROSEED, MULCHING OR
OTHER APPROPRIATE BMPS AS A RESULT OF SITE GRADING IN AREAS THAT WILL NOT
RECEIVE HARDSCAPE.
9.CONSTRUCT STORM AND IRRIGATION UTILITIES, CONCRETE, ASPHALT, AND PERMEABLE
PAVEMENTS, AS WELL AS STAIRS, CHEEK WALLS, AND MOW STRIPS FOR FENCING.
10.PLACE FILL SECTION AND LAWN/SEED FOR PLAYFIELD.
11.REMOVE TEMPORARY ESC FACILITIES UPON COMPLETION OF CONSTRUCTION AND ONLY
ONCE SITE IS STABILIZED, INSPECTED, AND APPROVED BY CITY OF RENTON INSPECTOR.
TESC CONSTRUCTION SEQUENCE
1.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE- CONSTRUCTION MEETING
SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT,
AND THE APPLICANT' S CONTRACTOR.
2.THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND
FEDERAL PERMITS PRIOR TO CONSTRUCTION.
3.ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE
WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL ( RENTON
SWDM), RENTON MUNICIPAL CODE ( RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD,
BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS
ASSOCIATION ( APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY
ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL
CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY.
4.APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT
CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION ( E.G. WATER, SEWER, GAS, ELECTRICAL.
ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A
SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER
DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY
DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN
APPROVAL FROM THE CITY.
5.A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN
PROGRESS.
6.HE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD
SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED
APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE
APPLICANT AND THE APPLICANT' S CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL
UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT
SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT
SHALL RECORD ON THE AS- BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND
ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE
ENGINEER OF RECORD IF A CONFLICT EXISTS.
7.VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 ( WA STATE
PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK, DATUM,
AND ELEVATIONS SHALL BE NOTED ON THE PLANS.
8.ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM
DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND MOISTURE CONTROL TESTS OF THE
WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS,
ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO
MORE THAN 92% OF MAXIMUM DRY DENSITY.
9.OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS
SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT
SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS.
10.ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START
OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE
EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED.
11.ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN
CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY.
12.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN
ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD
AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH
BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION
OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE
WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND
BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220. 00, 220. 10, AND 220. 20.
13.STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 5 INSIDE
AND OUTSIDE.
14.ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH
DUCTILE IRON, BOLT- LOCKING LIDS PER THE CITY STANDARD PLAN 204. 10, 204. 20, 204. 30,
204. 40, AND 204. 50. STRUCTURES SHALL HAVE:
·RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE
ROADWAY.
·ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY,
BUT OUTSIDE OF THE CURB/ GUTTER LINE.
·ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT- OF- WAY OR
IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT- OF- WAY AND
EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO.
15.BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1
EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM.
16.LIDS OF MANHOLES/ CATCH BASINS WITHIN PUBLIC RIGHT- OF- WAY SHALL NOT BE ADJUSTED TO
FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/ CATCH BASIN RIMS SHALL BE ADJUSTED TO BE
FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN.
17.ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT- OF- WAY SHALL BE OF SUFFICIENT LENGTH
TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE
DITCH.
18.ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND
QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE ( 1) FOOT AND SHALL MEET THE FOLLOWING
SPECIFICATIONS:
·4 - 8 INCH ROCK / 40 - 70% PASSING;
·2 - 4 INCH ROCK / 30 - 40% PASSING; AND
·LESS THAN 2 INCH ROCK / 10 - 20% PASSING.
19.FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED
AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW
CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE
CONNECTED TO ON- SITE BMPS.
20.THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT-
LOCKING LID MARKED " STORM” OR " DRAIN" SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE
POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY
STANDARD PLAN 227. 00.
21.ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR
LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO
CONSTRUCTION.
22.ALL NEWLY- INSTALLED AND NEWLY- REHABILITATED ( PUBLIC AND PRIVATE) STORM CONVEYANCE
SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD
PLAN 266. 00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO
RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS AND/ OR PAVEMENT.
23.ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE
WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A
REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE
SAME TIME THE MAIN STORM IS TESTED.
24.FOR ALL DISTURBED PERVIOUS AREAS ( COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE
DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND
REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH
COMPOST IN ACCORDANCE WITH STANDARD PLAN 264. 00.
25.ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE
APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/ OR LIABILITY CONNECTED WITH
STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER
FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION.
26.ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER
ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT
PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK
WITHIN THE TRAVELED RIGHT- OF- WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL
REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT
STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY.
27.PROJECTS LOCATED WITHIN THE CITY' S AQUIFER PROTECTION AREA ( APA) SHALL COMPLY WITH
SPECIAL REQUIREMENT # 6 OF THE RENTON SWDM AND AQUIFER PROTECTION REGULATIONS (
RMC 4-3-050).
28.PLACEMENT OF SURFACE APPURTENANCES ( CATCH BASIN/ MANHOLE LIDS, CLEANOUTS, INLETS,
ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES, BIKE
LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE
APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON- SLIP OR
NON- SKID LID PER ADA REQUIREMENTS.
29.CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE
MAINTAINED BY THE APPLICANT.
30.MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE
RENTON SWDM.
31.CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A
MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN
WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE
SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE
CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE
PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE
SURFACE, THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT
LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF
THIS TEST IS NOT CONCLUSIVE, THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR
LARGE AREAS ( E.G., PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE
WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO
THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781.
CITY OF RENTON SURFACE WATER STANDARD PLAN NOTES (PER CITY STD. PLANS 267.00 & 267.10)
R-432602
STAFF RECOMMENDS APPROVAL OF THE HAZEN HIGH SCHOOL MODERNIZATION, FILE NO.
LUA24-000349, SA-A, MOD, MOD, MOD AS DEPICTED IN THE SITE PLAN (EXHIBIT 2),
SUBJECT TO THE FOLLOWING CONDITIONS OF APPROVAL:
1.THE APPLICANT SHALL RECORD A FORMAL LOT COMBINATION IN ORDER TO ENSURE THE
EXISTING BUILDINGS AND PROPOSED IMPROVEMENTS ARE NOT BUILT ACROSS PROPERTY
LINES. THE INSTRUMENT SHALL BE RECORDED PRIOR TO THE ISSUANCE OF TEMPORARY
CERTIFICATE OF OCCUPANCY.
2.THE APPLICANT SHALL PLANT NEW SUPPLEMENTAL TREES ON THE SITE TO ACHIEVE THE
MINIMUM TREE DENSITY OF THIRTY (30) CREDITS PER NET ACRE. THE SPECIES AND
LOCATIONS OF THE TREES SHALL BE INDICATED ON A LANDSCAPE PLAN SUBMITTED TO
THE CURRENT PLANNING PROJECT MANAGER. ALTERNATIVELY, THE APPLICANT MAY PAY
INTO THE CITY’S URBAN FORESTRY PROGRAM FUND AS A FEE-IN-LIEU OF PROVIDING
ADDITIONAL SUPPLEMENTAL TREES OR PROPOSE A MIX OF NEW SUPPLEMENTAL TREES
AND PAYMENT OF A FEE-IN-LIEU. THE APPLICANT SHALL SUBMIT A LANDSCAPE PLAN OR
FEE-IN-LIEU REQUEST FOR REVIEW AND APPROVAL BY THE CURRENT PLANNING PROJECT
MANAGER PRIOR TO ISSUANCE OF THE BUILDING PERMIT APPLICATION.
3.ALL EXISTING DRIVEWAY CUTS, CURB RAMPS AND CROSSWALKS ALONG THE NE 10TH ST
FRONTAGE SHALL BE UPGRADED TO MEET CURRENT CITY AND ADA STANDARDS,
INCLUDING RECEIVING RAMPS FOR CROSSWALKS.
4.THE UNIMPROVED PORTION OF NE 10TH ST SHALL BE UPGRADED TO PROVIDE
HALF-STREET IMPROVEMENTS INCLUDING SIDEWALK, STREET LIGHTING, PLANTER STRIP
AND STREET TREES AS FEASIBLE IN RELATION TO THE ADJACENT HILLSIDE TO THE NORTH,
AND ASPHALT PAVEMENT TO THE FURTHEST EXTENT SOUTH AS FEASIBLE. THE FINAL
DESIGN OF THE IMPROVEMENTS INCLUDING PAVEMENT WIDTH, PLANTER WIDTH, STREET
LIGHTING LOCATIONS, AND STREET TREE LOCATIONS, SHALL BE REVIEWED AND APPROVED
BY THE PUBLIC WORKS PLAN REVIEWER. TEMPORARY BARRICADES SHALL BE INSTALLED
UNTIL SUCH A TIME THAT THE PROPERTIES TO THE SOUTH DEVELOP AND CONTINUE THE
THROUGH CONNECTION.
5.ALL EXISTING DRIVEWAY CUTS, CURB RAMPS AND CROSSWALKS ALONG THE HOQUIAM AVE
NE SHALL BE UPGRADED TO MEET CURRENT CITY AND ADA STANDARDS, INCLUDING THE
NORTHERN-MOST RAMP ADJACENT TO THE NORTHEAST PROPERTY CORNER OF THE SITE.
RECEIVING RAMPS FOR CROSSWALKS SHALL ALSO BE UPGRADED TO MEET THE CURRENT
STANDARDS.
6.THE EXISTING CROSSWALK AT THE NE 11TH CT INTERSECTION ADJACENT TO THE
SCHOOL’S PRIMARY ENTRANCE SHALL BE UPGRADED TO A PEDESTRIAN-ACTIVATED
PUSH-BUTTON RECTANGULAR RAPID FLASHING BEACON (RRFB) MEETING CITY STANDARD
DETAILS 141.1 THROUGH 141.5.
LAND USE CONDITIONS OF APPROVAL
TE
D
-
4
0
-
4
3
2
6
R-432602
DEVELOPMENT ENGINEERING
msippo 08/07/2025
X
X
X
E E
E
E
E
E
E
E
E
E
E
SS
CO
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
S
U
B
S
U
B
SUB
SUB
SUB
S
U
B
S
U
B
SUB
SUB
SUB
S
U
B
S
U
B
SUB
SUB
SUB
S
U
B
S
U
B
SUB
SUB
SUB
S
U
B
S
U
B
SUB
SUB
SUB
S
U
B
S
U
B
SUB
SUB
SUB
S
U
B
S
U
B
SUB
SUB
S
U
B
S
U
B
SUB
SUB
S
U
B
S
U
B
SUB
SUB
S
U
B
S
U
B
SUB
SUB
S
U
B
S
U
B
SUB
SUB
S
U
B
S
U
B
SUB
SUB
S
U
B
S
U
B
SUB
SUB
S
U
B
S
U
B
SUB
S
U
B
S
U
B
SUB
S
U
B
S
U
B
SUB
S
U
B
SUB
S
U
B
SUB
S
U
B
SUB
S
U
B
SUB
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SU
BSU
B
SU
B
SUB
SU
B
SU
B
SUB
SU
B SU
B
SU
B
SUB
SU
B
SD E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
EE
E
EE
E
E E
EE
EE
E E
E
E
E
E
E
E
E
E
E
E
E
E
SD
EE
E
EEEEEE
E
E
E
E
E
ESDSD
DU
V
A
L
L
A
V
E
.
N
.
E
.
HO
Q
U
I
A
M
A
V
E
.
N
.
E
.
N.E. 12TH ST.
N.E. 10TH ST.
N.E. 11TH PL
N.E. 11TH CT
N.E. 11TH ST
N.E. 10TH PL
GR
A
H
A
M
AV
E
N
.
E
.
FI
E
L
D
AV
E
N
.
E
.
EXISTING FIRE
HYDRANT
NE 10TH ST
ECO PAN FOR CONCRETE PUMPER TRUCK
CLEANOUT; FINAL LOCATION TO BE
COORDINATED IN FIELD DURING CONSTRUCTION.
ECO PAN USED FOR CONCRETE POUR IN
COURTYARD TO THE SOUTH FOR GREENHOUSE
PAD AND CONCRETE SIDEWALK REPLACEMENT
FOR INSTALLATION OF ACID WASTE PIPING
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
OVERALL SITE PLAN
CX04
CX01
CX03
CX05
CX06
PROJECT WORK
AREAS (TYP)
IMPROVED BASEBALL FIELD AND
GROUND SOURCE WELL ZONE
CX02
EXISTING
POWER POLE
NEW ELECTRICAL
PRIMARY SERVICE
GROUND SOURCE
WELL ZONE
GROUND SOURCE
PIPING IN/OUT
OF BUILDING
(2) TEMPORARY
PORTABLES TO BE
REMOVED AT END OF
PROJECT UNDER
SEPARATE PERMIT
MAINTAIN 20'
WIDE FIRE LANE
CX07
GROUND SOURCE
VAULT. LOCATION TBD.
EX CHURCH PROPERTY
NOTE: BREAKOUT SHEETS
VARY IN DRAWING SCALE
CONTRACTOR TO TAKE NOTE
OF SCALES ON EVERY SHEET
NE 10TH ST FROM EXISTING CUL-DE-SAC
WEST ALONG SCHOOL'S FRONTAGE TO BE
UPGRADED WITH PLANTER STRIP, STREET
LIGHTING, AND CONCRETE SIDEWALK
MEETING THE REQUIREMENTS FOR A
RESIDENTIAL ACCESS STREET SECTION.
SEE SHEETS C109 AND C209
EXISTING ADA RAMP AT THE NW CORNER
OF INTERSECTION OF HOQUIAM AVE NE &
NE 10TH ST TO BE UPGRADED TO MEET
ACCESSIBILITY REQUIREMENTS.
SEE SHEETS C109 AND C209
EXISTING ADA RAMP AT THE SE CORNER OF
INTERSECTION OF HOQUIAM AVE NE & NE
11TH CT TO BE UPGRADED TO MEET
ACCESSIBILITY REQUIREMENTS, INCLUDING
INSTALLATION OF A NEW COMPANION RAMP
ON EAST SIDE OF STREET. EXISTING
CROSSWALK TO BE REPLACED WITH NEW
THERMOPLASTIC CROSSWALK STRIPING
SEE SHEETS C108 AND C208
EXISTING DRIVEWAY CURB CUT
TO BE UPGRADED TO MEET
ACCESSIBILITY REQUIREMENTS
SEE SHEETS C108 AND C208
NOTE: FOR R.O.W.
IMPROVEMENTS SEE DETAILS
ON SHEETS C330 & C331
C109
C209
C109, C209
IMPROVED
SOFTBALL FIELD
EXISTING DRIVEWAY CURB CUT
TO BE UPGRADED TO MEET
ACCESSIBILITY REQUIREMENTS
SEE SHEETS C108 AND C208
EXISTING DRIVEWAY CURB CUT
TO BE UPGRADED TO MEET
ACCESSIBILITY REQUIREMENTS
SEE SHEETS C108 AND C208
C1
0
8
,
C2
0
8
C1
0
8
,
C2
0
8
SCALE 1"=80'
40 80 1600
EXISTING DRIVEWAY CURB CUT
TO BE UPGRADED TO MEET
ACCESSIBILITY REQUIREMENTS
SEE SHEETS C109 AND C209
EXISTING LIGHT POLE AND HH
EXISTING CABINET
KEYNOTE:
1.DEMOLISH AND REMOVE EX SECURITY
FENCING AND GATES, INCLUDING ANY
HARDWARE, OUTSIDE THE GYM/CAFETERIA
AREA COURTYARD. CONTRACTOR SHALL
SAWCUT 2' AROUND POSTS AND REMOVE
POSTS. PATCH WITH CONCRETE SIDEWALK
PAVEMENT.
2.DEMOLISH AND REMOVE EX SECURITY
FENCING AND GATES, INCLUDING ANY
HARDWARE, OUTSIDE THE CTE/D-WING
SCIENCE AREA COURTYARD. CONTRACTOR
SHALL SAWCUT 2' AROUND POSTS AND
REMOVE POSTS. PATCH WITH CONCRETE
SIDEWALK PAVEMENT.
1
2
FOR WORK IN
EX COURTYARD
SEE DETAIL
C303
10
CITY OF RENTON EROSION CONTROL WET SEASON REQUIREMENTS
ANY SITE WITH EXPOSED SOILS DURING THE WET SEASON (OCTOBER 1 TO APRIL 30) SHALL BE SUBJECT TO THE SPECIAL
PROVISIONS BELOW. IN ADDITION TO THE ESC COVER MEASURES (SEE SECTION D.2.1.2), THESE PROVISIONS INCLUDE
COVERING ANY NEWLY SEEDED AREAS WITH MULCH AND IDENTIFYING AND SEEDING AS MUCH DISTURBED AREA AS
POSSIBLE PRIOR TO SEPTEMBER 23 IN ORDER TO PROVIDE GRASS COVER FOR THE WET SEASON. A “WET SEASON ESC PLAN”
MUST BE SUBMITTED AND APPROVED BY THE CITY BEFORE WORK PROCEEDS OR CONTINUES.
THE FOLLOWING PROVISIONS FOR WET SEASON CONSTRUCTION ARE DETAILED IN APPENDIX D OF THE 2017 CITY OF RENTON
SURFACE WATER DESIGN MANUAL. PLEASE ENSURE YOUR SITE IS PROTECTED AND COMPLIES WITH THE SPECIAL PROVISIONS
OUTLINED BELOW.
WET SEASON SPECIAL PROVISIONS
ALL OF THE FOLLOWING PROVISIONS FOR WET SEASON CONSTRUCTION ARE DETAILED IN THE REFERENCED SECTIONS.
THESE REQUIREMENTS ARE LISTED HERE FOR THE CONVENIENCE OF THE DESIGNER AND THE REVIEWER.
1.THE ALLOWED TIME THAT A DISTURBED AREA MAY REMAIN UNWORKED WITHOUT COVER MEASURES IS REDUCED TO
TWO CONSECUTIVE WORKING DAYS, RATHER THAN SEVEN (SECTION D.2.1.2).
2.STOCKPILES AND STEEP CUT AND FILL SLOPES ARE TO BE PROTECTED IF UNWORKED FOR MORE THAN 12 HOURS
(SECTION D.2.1.2).
3.COVER MATERIALS SUFFICIENT TO COVER ALL DISTURBED AREAS SHALL BE STOCKPILED ON SITE (SECTION D.2.1.2).
4.ALL AREAS THAT ARE TO BE UNWORKED DURING THE WET SEASON SHALL BE SEEDED WITHIN ONE WEEK OF THE
BEGINNING OF THE WET SEASON (SECTION D.2.1.2.6).
5.MULCH IS REQUIRED TO PROTECT ALL SEEDED AREAS (SECTION D.2.1.2.2).
6.FIFTY LINEAR FEET OF SILT FENCE (AND THE NECESSARY STAKES) PER ACRE OF DISTURBANCE MUST BE STOCKPILED ON
SITE (SECTION D.2.1.3.1).
7.CONSTRUCTION ROAD AND PARKING LOT STABILIZATION ARE REQUIRED FOR ALL SITES UNLESS THE SITE IS UNDERLAIN
BY COARSE-GRAINED SOIL (SECTION D.2.1.4.2).
8.SEDIMENT RETENTION IS REQUIRED UNLESS NO OFFSITE DISCHARGE IS ANTICIPATED FOR THE SPECIFIED DESIGN FLOW
(SECTION D.2.1.5).
9.SURFACE WATER CONTROLS ARE REQUIRED UNLESS NO OFFSITE DISCHARGE IS ANTICIPATED FOR THE SPECIFIED
DESIGN FLOW (SECTION D.2.1.6).
10.PHASING AND MORE CONSERVATIVE BMPS MUST BE EVALUATED FOR CONSTRUCTION ACTIVITY NEAR SURFACE WATERS
(SECTION D.2.4.3).
11.ANY RUNOFF GENERATED BY DEWATERING MAY BE REQUIRED TO DISCHARGE TO THE SANITARY SEWER (WITH
APPROPRIATE DISCHARGE AUTHORIZATION), PORTABLE SAND FILTER SYSTEMS, OR HOLDING TANKS (SECTION D.2.2).
SAWCUT AND REMOVE EX
ASPHALT PAVEMENT FOR
UTILITY INSTALLATION. PATCH
WITH HEAVY ASPHALT
PAVEMENT SECTION.
SEE DETAIL
C300
7
EX ASPHALT
ACCESS DRIVE
EX DOUBLE SWING VEHICLE
GATE FOR CONSTRUCTION
ACCESS TO SITE
R-432603
TE
D
-
4
0
-
4
3
2
6
R-432603
DEVELOPMENT ENGINEERING
msippo 08/07/2025
SW
SW
SW
SW
SW
SW
SW
SW
4'
4.5'
9.
9
'
16
.
4
'
PROTECT EX
CONCRETE CURB
TO REMAIN (TYP)
SAWCUT AND REMOVE
EX CONCRETE
SIDEWALK
PROTECT EX
CONCRETE CROSSING
AND CROSSWALK
STRIPING TO REMAIN
INSTALL STRAW
WATTLES
SEE DETAIL (TYP)
C110
8
17
.
7
'
VEG
VEG HO
Q
U
I
A
M
A
V
E
.
N
.
E
.
(A
D
E
D
I
C
A
T
E
D
P
U
B
L
I
C
R
I
G
H
T
O
F
W
A
Y
)
REMOVE ALL (14) EX 24"
CONCRETE BOLLARDS AND
SURROUNDING PAVING TO INSTALL
NEW VEHICULAR RATED TRAFFIC
BOLLARDS (TYP) SEE SHEET C201
IP
IP
INSTALL CB PROTECTION
SEE DETAIL (TYP)
C110
7
PROTECT EX 10" STORM
DRAIN PIPE TO REMAIN. TOP
OF PIPE IS APPROXIMATELY
2-FT BELOW EX GRADE
PROTECT EX PEDESTRIAL
LIGHT POLE TO REMAIN
REMOVE EX STEAM VENT COVER
AND DEMO AND REMOVE 8"
MIN. OF EXISTING BELOW
GRADE CONCRETE WALL AND
THEN INFILL PER ARCH'L PLANS
SALVAGE AND REMOVE, CLEAN,
PAINT, AND REINSTALL EX BOLT
DOWN BENCH. SEE SHEET
C201 FOR BENCH LOCATIONS.
REMOVE EX FDC TO
BE RELOCATED.
COORDINATE WITH
MECH'L ENGINEER
REMOVE EX METAL RAILING
EXTENTS OF PROPOSED
BUILDING VESTIBULE
PROTECT EX STORM
CLEANOUT CASTING TO
REMAIN
REMOVE EX BENCH
AND POSTS CAST
INTO EX CONCRETE
PROTECT EX BUILDING
COLUMNS TO REMAIN
REMOVE EX
CONCRETE STAIR
PAD
SAWCUT AND REMOVE EX CONCRETE
PAVEMENT AS REQUIRED TO CONSTRUCT
NEW BLDG VESTIBULE AND REGRADED
PORTION OF CONCRETE PLAZA.
SEE SHEET C201
SW
INSTALL STRAW
WATTLES
SEE DETAIL (TYP)
C110
8
PROTECT EX
CONCRETE CURB
TO REMAIN (TYP)
SW
SW
SW
SW
SW
SW
SW
SW
SW
S
W
S
W
SW
SW
SW
SW
SW
SW
SW
SW
S
W
S
W SW SW
SW
SW
SAWCUT AND REMOVE EX
CONCRETE AND ASPHALT AS
REQUIRED TO REPLACE EX
ACCESSIBLE CURB RAMP
PROTECT EX
PEDESTRIAL LIGHT
POLE TO REMAIN
INSTALL TREE
PROTECTION FENCING
SEE DETAIL
VEG
REMOVE AND
REINSTALL PROTECT EX
"STOP" SIGN AND POST
PROTECT EX FLAG
POLE TO REMAIN
CONTRACTOR SHALL MAKE A
RECORD OF EXISTING SCORE/JOINT
LINES TO BE MATCHED FOR
FINISHED CONCRETE CONDITION.
SEE SHEET C201
SW
EX BUILDING
OVERHANG/CANOPY
ABOVE (TYP)
4'
SAWCUT AND REMOVE EX
CONCRETE SIDEWALK
PROTECT EX
CONCRETE CURB
TO REMAIN (TYP)
REMOVE 6" AND
10" CEDAR TREES
REMOVE AND REINSTALL ADA
PARKING SIGN AND POST
REMOVE AND REINSTALL ADA
PARKING SIGN AND POST
REMOVE AND REINSTALL
BUS LOADING SIGN AND
POST
CONTRACTOR SHALL MAKE A
RECORD OF EXISTING SCORE/JOINT
LINES TO BE MATCHED FOR
FINISHED CONCRETE CONDITION.
SEE SHEET C201 (TYP)
CONTRACTOR SHALL MAKE A
RECORD OF EXISTING CORE/JOINT
LINES TO BE MATCHED FOR
FINISHED CONCRETE CONDITION.
SEE SHEET C201 (TYP)
TEMPORARY
CONSTRUCTION
FENCING (TYP)
SEE DETAIL
C110
10
SW
SW
SW
SW
SW
SW
VEG
1.5'
SAWCUT AND
REMOVE EX
ASPHALT RAMP
PROTECT EX
STOP SIGN
PROTECT
EX CURB
6'
EXISTING 10" WATER MAIN TO BE PROTECTED AT ALL TIMES.
PROTECTION SHALL INCLUDE, BUT NOT LIMITED TO, PROHIBITION OF
HEAVY MACHINERY AND DRILLING EQUIPMENT ON TOP OF MAIN OR
WITHIN EASEMENT. VIBRATIONAL TESTING MAY BE REQUIRED FOR
ANY DRILLING OR PILING OCCURRING NEAR THE MAIN. ADDITIONALLY,
ANY MACHINERY CROSSING THE WATER MAIN IN UNPAVED AREAS
WILL BE REQUIRED SHEETING OR SIMILAR MECHANISM TO ENSURE
THAT THE MAIN IS NOT SUBJECT TO DAMAGE LOADS.
C111
10
ECO PAN FOR CONCRETE TRUCK
CLEANOUT; FINAL LOCATION TO
BE COORDINATED IN FIELD
DURING CONSTRUCTION.
PROTECT EX CONCRETE
SEAT WALL TO REMAIN
VEG
SW
SW
SW
SW
SW
SW
SW
SW
SW
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
SCALE 1"=10'
5 10 200
HAZEN HIGH SCHOOL MODERNIZATION
DEMOLITION AND TESC PLAN
TREE PROTECTION
INLET PROTECTION
PROPERTY LINE
TEMP CONSTRUCTION FENCINGCF
IP
VEG
SAWCUT LINE
REMOVE CURBING
REMOVE ASPHALT PAVEMENT
REMOVE CONCRETE PAVEMENT
CONSTRUCTION FENCING NOTE:
INSTALL CONSTRUCTION FENCING AROUND
LIMITS OF WORK TO PROTECT STAFF AND
STUDENTS AND SECURE JOBSITE. CONTRACTOR
SHALL ERECT FENCE AROUND JOBSITE AND
ADJUST AS CONSTRUCTION CONDITIONS
CHANGE OR AS PHASING ALLOWS.
CONTRACTOR CAN UTILIZE EXISTING
PERIMETER FENCING AS SECURITY FENCING
AND THEN SUPPLEMENT ON THE WEST SIDE OF
THE SITE AS NEEDED. ANY EXISTING
CHAINLINK FENCING THE CONTRACTOR ELECTS
TO UTILIZE DURING CONSTRUCTION SHALL
APPLY (IE ZIPTIES OR OTHER MEANS) HIGH
VISIBILITY MATERIAL OR SIMILAR METHOD TO
BE APPLIED TO FENCING TO DELINEAT AS
CONSTRUCTION ZONE (TYP). ANY SECTIONS OF
EXISTING FENCING THAT IS NOT 6-FT HIGH
SHALL HAVE TEMPORARY 6-FT HIGH
CHAINLINK FENCING INSTALLED NEXT TO IT.
SEE DETAIL 10/C110.
SEE SHEET C001 FOR CITY OF RENTON
ESC STANDARD PLAN NOTES
CONTINUATION - SEE TOP RIGHT
CONTINUATION - SEE BOTTOM LEFT
REMOVE TREE(S)
FOR WORK IN THE
RIGHT-OF-WAY
SEE SHEET C108
SEE SHEET C001 FOR TESC
CONSTRUCTION SEQUENCE NOTES
STRAW WATTLES SWSW
R-432604
TE
D
-
4
0
-
4
3
2
6
R-432604
DEVELOPMENT ENGINEERING
msippo 08/07/2025
□
IP
IP
INSTALL CB
PROTECTION (TYP)
SEE DETAIL
C110
7
FF
IS
FF
IS
FF
INTERCEPTOR SWALE
WITH ROCK CHECK DAMS
AT 50' O.C. SPACING
SEE DETAILS
C110
6
C111
5
INSTALL SILT
FENCE (TYP)
SEE DETAIL
C111
9
TEMPORARY DUPLEX
SUMP PUMPS
INSTALLED AT LOW
POINT ON SITE
SEE DETAIL
C111
8
FF
CONTRACTOR TO UTILIZE
EXISTING SITE FENCING
FOR CONSTRUCTION
PERIMETER FENCING AND
SUPPLEMENT AS NEEDED
SEE CONSTRUCTION
FENCING NOTE WITHIN
THIS SHEET
PROTECT EX CATCH BASIN
AND STORM PIPING DURING
GROUND SOURCE WELL
INSTALLATION
PROTECT EX CATCH BASIN
AND STORM PIPING
DURING GROUND SOURCE
WELL INSTALLATION
EXISTING 10" WATER MAIN TO BE PROTECTED AT ALL TIMES.
PROTECTION SHALL INCLUDE, BUT NOT LIMITED TO,
PROHIBITION OF HEAVY MACHINERY AND DRILLING
EQUIPMENT ON TOP OF MAIN OR WITHIN EASEMENT.
VIBRATIONAL TESTING MAY BE REQUIRED FOR ANY DRILLING
OR PILING OCCURING NEAR THE MAIN. ADDITIONALLY, ANY
MACHINERY CROSSING THE WATER MAIN IN UNPAVED AREAS
WILL BE REQUIRED SHEETING OR SIMILAR MECHANISM TO
ENSURE THAT THE MAIN IS NOT SUBJECT TO DAMAGE LOADS.
PUMP CONSTRUCTION STORMWATER
TO SEDIMENT SETTLEMENT TANKS.
PUMP LINE TO BE TAKEN OFF LINE
AND REMOVED ONCE DETENTION
VAULT IS INSTALLED AND READY TO
USE AS TEMPORARY TESC MEASURE
PROTECT EX
BACKSTOP TO REMAIN
4" GV (R)
FF
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
DEMOLITION AND TESC PLAN
LEGEND
SAWCUT LINE
REMOVE CURBING
REMOVE ASPHALT PAVEMENT
REMOVE CONCRETE PAVEMENT
TREE PROTECTION
INLET PROTECTION
PROPERTY LINE
TEMP CONSTRUCTION FENCINGCF
IP
VEG
SEE SHEET C001 FOR CITY OF RENTON
ESC STANDARD PLAN NOTES
MATCHLINE - SEE SHEET C103
CONSTRUCTION FENCING NOTE:
INSTALL CONSTRUCTION FENCING AROUND LIMITS OF WORK TO
PROTECT STAFF AND STUDENTS AND SECURE JOBSITE. CONTRACTOR
SHALL ERECT FENCE AROUND JOBSITE AND ADJUST AS
CONSTRUCTION CONDITIONS CHANGE OR AS PHASING ALLOWS.
CONTRACTOR CAN UTILIZE EXISTING PERIMETER FENCING AS
SECURITY FENCING AND THEN SUPPLEMENT ON THE WEST SIDE OF
THE SITE AS NEEDED. ANY EXISTING CHAINLINK FENCING THE
CONTRACTOR ELECTS TO UTILIZE DURING CONSTRUCTION SHALL
APPLY (IE ZIPTIES OR OTHER MEANS) HIGH VISIBILITY MATERIAL OR
SIMILAR METHOD TO BE APPLIED TO FENCING TO DELINEAT AS
CONSTRUCTION ZONE (TYP). ANY SECTIONS OF EXISTING FENCING
THAT IS NOT 6-FT HIGH SHALL HAVE TEMPORARY 6-FT HIGH
CHAINLINK FENCING INSTALLED NEXT TO IT. SEE DETAIL 10/C110.
SEE SHEET C001 FOR TESC
CONSTRUCTION SEQUENCE NOTES
SILT FENCE
INTERCEPTOR SWALEIS
FF
R-432605
TE
D
-
4
0
-
4
3
2
6
R-432605
DEVELOPMENT ENGINEERING
msippo 08/07/2025
DU
V
A
L
L
A
V
E
.
N
.
E
.
(A
D
E
D
I
C
A
T
E
D
P
U
B
L
I
C
R
I
G
H
T
O
F
W
A
Y
)
IMPROVED BASEBALL FIELD.
SEE LANDSCAPE PLANS AND
CIVIL SHEET C203
EXISTING CITY OF RENTON
WATER EASEMENT TO BE
PROTECTED AT ALL TIMES
15'
IP
INSTALL CB
PROTECTION (TYP)
SEE DETAIL
C110
7
IP
IP
IP
PUMP "CLEAN" STORMWATER FROM TEMP
SEDIMENT SETTLEMENT TANKS TO EXISTING
CATCH BASIN. CONTRACTOR TO ENSURE ALL
DISCHARGE MEETS TURBIDITY REQUIREMENTS.
PUMP LINE TO BE TAKEN OFF LINE AND REMOVED
ONCE DETENTION VAULT IS INSTALLED AND
READY TO USE AS TEMPORARY TESC MEASURE
FF
IS
FF
FF
IS
PUMP CONSTRUCTION STORMWATER TO
SEDIMENT SETTLEMENT TANKS. PUMP LINE
TO BE TAKEN OFF LINE AND REMOVED ONCE
DETENTION VAULT IS INSTALLED AND READY
TO USE AS TEMPORARY TESC MEASURE
FFINTERCEPTOR SWALE
WITH ROCK CHECK DAMS
AT 50' O.C. SPACING
SEE DETAILS
C110
6
C111
5
TEMPORARY DUPLEX
SUMP PUMPS
INSTALLED AT LOW
POINT ON SITE
SEE DETAIL
C111
8
PUMP CONSTRUCTION STORMWATER
TO SEDIMENT SETTLEMENT TANKS.
PUMP LINE TO BE TAKEN OFF LINE
AND REMOVED ONCE DETENTION
VAULT IS INSTALLED AND READY TO
USE AS TEMPORARY TESC MEASURE
INSTALL SILT
FENCE (TYP)
SEE DETAIL
C111
9
INTERCEPTOR SWALE
WITH ROCK CHECK DAMS
AT 50' O.C. SPACING
SEE DETAILS
C110
6
C111
5
FF
BOE = 442.50
FF
APPROXIMATE LIMITS OF
PROPOSED DETENTION SYSTEM
EXCAVATION FOR BASEBALL FIELD.
SEE SHEET C203
SALVAGE AND REMOVE EX
PULL UP BARS TO BE
REINSTALLED AFTER
COMPLETION OF GROUND
SOURCE WELL FIELD
(4) 18,900 GALLON CAPACITY TEMPORARY
SEDIMENT SETTLEMENT TANKS ("BAKER TANK" OR
EQUAL). CONTRACTOR SHALL PROVIDE ALL PUMPS
REQUIRED TO MANAGE CONSTRUCTION
STORMWATER AND DISCHARGE AT THE SITE.
SETTLEMENT TANKS TO BE TAKEN OFF LINE AND
REMOVED ONCE DETENTION VAULT IS INSTALLED
AND READY TO USE AS TEMPORARY TESC MEASURE
PROTECT EX FIELD
PERIMETER FENCING
TO REMAIN
PROTECT EXISTING
SYNTHETIC TURF
DUGOUT TO REMAIN
PROTECT EXISTING
CONCRETE TO REMAIN
PROTECT EXISTING
SYNTHETIC TURF DUGOUT
AND SURROUNDING
FENCE TO REMAIN
PROTECT EXISTING 8"
STORM DURING PROPOSED
STORM INSTALLATION
SEE SHEET C203 (TYP)
PROTECT EX
CONCRETE RETAINING
WALL AND FENCE
IP
SUPPLEMENT SITE FENCING
DURING CONSTRUCTION AS
NEEDED TO SECURE
CONSTRUCTION WORK AREAS
SEE CONSTRUCTION FENCING
NOTE WITHIN SHEET
PROTECT EX SDMH AND AND
SSMH AND ASSOCIATED
PIPING DURING GROUND
SOURCE WELL INSTALLATION
CONTRACTOR TO HAVE THE OPTION TO
UTILIZE PROPOSED DETENTION SYSTEM FOR
CONSTRUCTION STORMWATER SETTLEMENT
VAULT MUST BE CLEANED OF ALL SEDIMENT
PRIOR TO THE END OF CONSTRUCTION
IP
IP
PROTECT EX TREES TO
REMAIN UNLESS
OTHERWISE NOTED
VEG
REMOVE AND REPLACE PORTION OF
EXISTING SIDEWALK AND ASPHALT AS
NEEDED FOR UTILITY INSTALLATION
REMOVE AND REPLACE
PORTION OF EXISTING
FENCE AS NEEDED FOR
UTILITY INSTALLATION
APPROXIMATE LIMITS OF
PROPOSED STORM PIPING
EXCAVATION FROM DETENTION
SYSTEM FOR BASEBALL FIELD.
SEE SHEET C203 FOR DEPTH OF
STORM SYSTEM.
REMOVE EX (2) 6" &
(1) 8" DECIDUOUS
TREE CLUSTER
PROTECT EX 10"
DECIDUOUS TREE
NOTE: ARBORIST SHALL BE ON-SITE
DURING TREE REMOVAL AND
STORM PIPING INSTALLATION
REMOVE EX 8"
DECIDUOUS TREE
REMOVE EX 26"
AND 14"
DECIDUOUS TREE
REMOVE EX 10"
DECIDUOUS TREE
REMOVE EX 6"
DECIDUOUS TREE
IP
IP
CONTRACTOR TO UTILIZE 4'
MAX VERTICAL CUT AT
BOTTOM OF EXCAVATION
450
45
5
448
449
451
452
453
454
1:1 MAX CUT SLOPE
C111
3
EXISTING 10" WATER MAIN TO BE PROTECTED AT ALL TIMES.
PROTECTION SHALL INCLUDE, BUT NOT LIMITED TO,
PROHIBITION OF HEAVY MACHINERY AND DRILLING
EQUIPMENT ON TOP OF MAIN OR WITHIN EASEMENT.
VIBRATIONAL TESTING MAY BE REQUIRED FOR ANY DRILLING
OR PILING OCCURRING NEAR THE MAIN. ADDITIONALLY, ANY
MACHINERY CROSSING THE WATER MAIN IN UNPAVED AREAS
WILL BE REQUIRED SHEETING OR SIMILAR MECHANISM TO
ENSURE THAT THE MAIN IS NOT SUBJECT TO DAMAGE LOADS.
CF
4
5
0
4
5
5
REMOVE EX
22" AND 24"
CONIFER TREE
REMOVE AND REPLACE EX
FENCE AS NEEDED FOR
DETENTION EXCAVATION AND
STORM INSTALLATION
IP
EXISTING 10" PRIVATE CLAY SEWER MAIN TO BE PROTECTED AT
ALL TIMES. PROTECTION SHALL INCLUDE, BUT NOT LIMITED TO,
PROHIBITION OF HEAVY MACHINERY AND DRILLING EQUIPMENT
ON TOP OF MAIN, VIBRATIONAL TESTING MAY BE REQUIRED FOR
ANY DRILLING OR PILING OCCURRING NEAR THE MAIN.
ADDITIONALLY, ANY MACHINERY CROSSING THE SEWER MAIN
IN UNPAVED AREAS WILL BE REQUIRED TO UTILIZE SHEETING
OR SIMILAR MECHANISM TO ENSURE THAT DAMAGE DOES NOT
OCCUR TO THE MAIN.
VEG
REMOVE EX 26"
CONIFER TREE
PROTECT EX
FENCE
PROTECT EX STORM
TO REMAIN
18'
INSTALL TEMPORARY CONCRETE
ECOLOGY BLOCKS LEVEL OUT THE
CONSTRUCTION ENTRANCE IN THIS
AREA. BLOCKS SHALL 2-HIGH MAX
AND EMBED 12" MIN.
STABILIZED
CONSTRUCTION ACCESS
SEE DETAIL
C110
5
MATCH EX ASPHALT
GRADE AT TRANSITION
EX ASPHALT DRIVE
MAINTAIN EX ASPHALT PAVEMENT
FOR CONSTRUCTION ACCESS
15' MIN
CE
17
9
'
REMOVE SECTION OF EX 4-FT
HIGH CHAINLINK FENCE,
POSTS, AND CONCRETE
FOOTINGS & CURB
REMOVE THIS PORTION OF EX 10-FT
HIGH CHAINLINK FENCE AND GATE,
INCLUDING POSTS AND CONCRETE
FOOTINGS
SAWCUT AND REMOVE PORTION OF
EX CONCRETE CURB AND CHAINLINK
FENCE TO INSTALL NEW FOUL POLE
SAWCUT AND REMOVE PORTION OF
EX CONCRETE CURB AND CHAINLINK
FENCE TO INSTALL NEW FOUL POLE
FF
FF
CF
INSTALL SILT FENCE
ON HILLSIDE OF UTILITY
EXCAVATION (TYP)
SEE DETAIL
C111
9
PROTECT EX CATCH BASIN
AND ASSOCIATED STORM
PIPING TO REMAIN
FF
FF
31
'
10" DI WATERMAIN
(PER CONTRACTOR
POTHOLE)
4" GV (R)
PROTECT EX GATE VALVE TO
REMAIN. ECOLOGY BLOCKS
SHALL NOT BE PLACED ON
TOP OF EX WATER VALVE
PROTECT EX GATE
VALVE TO REMAIN
10" GV (R)
10" DI WATERMAIN
(PER SURVEY)
CE
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DEMOLITION AND TESC PLAN
LEGEND
SAWCUT LINE
REMOVE CURBING
REMOVE ASPHALT PAVEMENT
REMOVE CONCRETE PAVEMENT
TREE PROTECTION
INLET PROTECTION
PROPERTY LINE
TEMP CONSTRUCTION FENCINGCF
IP
VEG
SEE SHEET C001 FOR CITY OF RENTON
ESC STANDARD PLAN NOTES
SEE SHEET C102 FOR TESC
CONSTRUCTION SEQUENCE NOTES
MATCHLINE - SEE SHEET C102
MATCHLINE - SEE SHEET C104
BOTTOM OF EXCAVATION
LEGEND
SCALE 1"=20'
0 10 20 40
CONSTRUCTION FENCING NOTE:
INSTALL CONSTRUCTION FENCING AROUND
LIMITS OF WORK TO PROTECT STAFF AND
STUDENTS AND SECURE JOBSITE. CONTRACTOR
SHALL ERECT FENCE AROUND JOBSITE AND
ADJUST AS CONSTRUCTION CONDITIONS CHANGE
OR AS PHASING ALLOWS. CONTRACTOR CAN
UTILIZE EXISTING PERIMETER FENCING AS
SECURITY FENCING AND THEN SUPPLEMENT ON
THE WEST SIDE OF THE SITE AS NEEDED. ANY
EXISTING CHAINLINK FENCING THE CONTRACTOR
ELECTS TO UTILIZE DURING CONSTRUCTION SHALL
APPLY (IE ZIPTIES OR OTHER MEANS) HIGH
VISIBILITY MATERIAL OR SIMILAR METHOD TO BE
APPLIED TO FENCING TO DELINEAT AS
CONSTRUCTION ZONE (TYP). ANY SECTIONS OF
EXISTING FENCING THAT IS NOT 6-FT HIGH SHALL
HAVE TEMPORARY 6-FT HIGH CHAINLINK FENCING
INSTALLED NEXT TO IT. SEE DETAIL 10/C110.
SILT FENCEFF
INTERCEPTOR SWALEIS
CONSTRUCTION ENTRANCE
ACCESS TO SITE VIA EX ASPHALT DRIVE
VIA DOUBLE SWING GATE LOCATED
NEAR SE CORNER OF TRACK & FIELD
AT NE 10TH STREET SEE SHEET C010
R-432606
TE
D
-
4
0
-
4
3
2
6
R-432606
DEVELOPMENT ENGINEERING
msippo 08/07/2025
15
'
EXISTING CITY OF
RENTON WATER
EASEMENT
15'
EXISTING CITY OF
RENTON WATER
EASEMENT
PRIVATE
STORM MAIN
CITY OF RENTON
WATER MAIN
REMOVE PORTION OF EX
GRASS FIELD AS REQ'D TO
INSTALL NEW GROUND SOURCE
PIPING AND VAULT AND
ELECTRICAL CONDUITS. SEE
SHEET C204 (TYP)
IP
IP
INSTALL CB
PROTECTION (TYP)
SEE DETAIL
C110
7
IP
SAWCUT AND REMOVE EX
ASPHALT PAVEMENT FOR
UTILITY INSTALLATION
SEE SHEET C204
FF
REMOVE GRAVEL
SAWCUT AND REMOVE PORTION
OF EX CONCRETE PAVEMENT FOR
NEW MECH'L PAD INSTALLATION.
SEE SHEET C204.
EX BASEBALL FIELD SUBDRAINAGE
TIE IN POC AT EX CATCH BASIN.
STORMWATER THEN DRAINS WEST.
SEE SHEET C103
SAWCUT AND REMOVE EX
ASPHALT PAVEMENT FOR
UTILITY INSTALLATION
SEE SHEET C204.
PROTECT EXISTING
BASEBALL FIELD PERIMETER
FENCING TO REMAIN
SILT FENCE (TYP)
SEE DETAIL
C111
9
IMPROVED BASEBALL FIELD.
SEE LANDSCAPE PLANS AND
CIVIL SHEET C204
EXISTING 10" WATER MAIN TO BE PROTECTED AT ALL TIMES.
PROTECTION SHALL INCLUDE, BUT NOT LIMITED TO,
PROHIBITION OF HEAVY MACHINERY AND DRILLING
EQUIPMENT ON TOP OF MAIN OR WITHIN EASEMENT.
VIBRATIONAL TESTING MAY BE REQUIRED FOR ANY DRILLING
OR PILING OCCURRING NEAR THE MAIN. ADDITIONALLY, ANY
MACHINERY CROSSING THE WATER MAIN IN UNPAVED AREAS
WILL BE REQUIRED SHEETING OR SIMILAR MECHANISM TO
ENSURE THAT THE MAIN IS NOT SUBJECT TO DAMAGE LOADS.
PROTECT EX STAIR INSTALL
TEMPORARY STEEL PLATES OR
OTHER MEANS AS SHORING;
CONTRACTOR SHALL ADJUST
LIMITS AS FIELD CONDITIONS
CHANGE
PROTECT EX RAMP
REMOVE FENCING AS
NEEDED TO INSTALL
GROUND SOURCE
WELL PIPING
18'
INSTALL TEMPORARY CONCRETE
ECOLOGY BLOCKS LEVEL OUT THE
CONSTRUCTION ENTRANCE IN THIS
AREA. BLOCKS SHALL 2-HIGH MAX
AND EMBED 12" MIN.
STABILIZED
CONSTRUCTION ACCESS
SEE DETAIL
C110
5
MATCH EX ASPHALT
GRADE AT TRANSITION
EX ASPHALT DRIVE
MAINTAIN EX ASPHALT PAVEMENT
FOR CONSTRUCTION ACCESS
17
9
'
CE
10" DI WATERMAIN
(PER SURVEY)
10" DI WATERMAIN
(PER CONTRACTOR POTHOLE)
REMOVE EX CONCRETE
PAD AT DOOR
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
SCALE 1"=10'
5 10 200
HAZEN HIGH SCHOOL MODERNIZATION
DEMOLITION AND TESC PLAN
SEE SHEET C001 FOR CITY OF RENTON
ESC STANDARD PLAN NOTES
SEE SHEET C102 FOR TESC
CONSTRUCTION SEQUENCE NOTES
LEGEND
SAWCUT LINE
REMOVE CURBING
REMOVE ASPHALT PAVEMENT
REMOVE CONCRETE PAVEMENT
TREE PROTECTION
INLET PROTECTION
PROPERTY LINE
TEMP CONSTRUCTION FENCINGCF
IP
VEG
MATCHLINE - SEE SHEET C103
CONSTRUCTION FENCING NOTE:
INSTALL CONSTRUCTION FENCING AROUND
LIMITS OF WORK TO PROTECT STAFF AND
STUDENTS AND SECURE JOBSITE. CONTRACTOR
SHALL ERECT FENCE AROUND JOBSITE AND
ADJUST AS CONSTRUCTION CONDITIONS CHANGE
OR AS PHASING ALLOWS. CONTRACTOR CAN
UTILIZE EXISTING PERIMETER FENCING AS
SECURITY FENCING AND THEN SUPPLEMENT ON
THE WEST SIDE OF THE SITE AS NEEDED. ANY
EXISTING CHAINLINK FENCING THE CONTRACTOR
ELECTS TO UTILIZE DURING CONSTRUCTION SHALL
APPLY (IE ZIPTIES OR OTHER MEANS) HIGH
VISIBILITY MATERIAL OR SIMILAR METHOD TO BE
APPLIED TO FENCING TO DELINEAT AS
CONSTRUCTION ZONE (TYP). ANY SECTIONS OF
EXISTING FENCING THAT IS NOT 6-FT HIGH SHALL
HAVE TEMPORARY 6-FT HIGH CHAINLINK FENCING
INSTALLED NEXT TO IT. SEE DETAIL 10/C110.
SILT FENCEFF
R-432607
TE
D
-
4
0
-
4
3
2
6
R-432607
DEVELOPMENT ENGINEERING
msippo 08/07/2025
N.E. 10TH ST.
( A DEDICATED PUBLIC RIGHT OF WAY)
IP
IP
INSTALL CB PROTECTION
SEE DETAIL (TYP)
C110
7
FF
FF
IS
INTERCEPTOR SWALE
WITH ROCK CHECK DAMS
AT 50' O.C. SPACING
SEE DETAILS
C110
6
C111
5
INSTALL SILT FENCE
AROUND PERIMETER
OF FIELD (TYP)
SEE DETAIL
C111
9
BOE = 470.50
SAWCUT AND REMOVE EX
ASPHALT PAVEMENT FOR
UTILITY INSTALLATION
SEE SHEET C205
REMOVE PORTION OF EX
LAWN, GRAVEL PATH AND
ASPHALT AS REQ'D TO INSTALL
NEW ELECTRICAL CONDUITS. SEE
SHEET C205
APPROXIMATE LIMITS OF PROPOSED
DETENTION SYSTEM EXCAVATION FOR
SOFTBALL FIELD. SEE SHEET C205
IP
IP
IP
IP
IP
PROTECT EXISTING
FENCE AND TRACK
SURFACING TO REMAIN
PROTECT EX
COVERED DUGOUT
PROTECT EX
SYNTHETIC GRASS
SURFACING
PROTECT EX
SYNTHETIC GRASS
SURFACING
REMOVE EX 4-FT HIGH
CHAINLINK FENCE. PROTECT EX
POSTS, CONCRETE FOOTINGS,
AND PERIMETER CURB TO
REMAIN AND BE RE-USED.
SEE L'SCAPE PLANS.
PROTECT EX CATCH
BASIN TO REMAIN
IP
IP
IP
IP
CONTRACTOR TO UTILIZE
4' MAX VERTICAL CUT AT
BOTTOM OF EXCAVATION
1:1 MAX CUT SLOPE
475
476
477
475
476
477
C111
4
SAWCUT AND REMOVE
EXISTING CONCRETE
DRIVEWAY, CURB/GUTTER,
AND ASPHALT PAVING
IP
EX WATER
DISTRICT 90
WATER MAIN
IS
TEMPORARY DUPLEX
SUMP PUMPS
INSTALLED AT LOW
POINT ON SITE
SEE DETAIL
C111
8
PUMP CONSTRUCTION
STORMWATER TO
TEMPORARY SEDIMENT
SETTLEMENT TANK
PUMP "CLEAN" STORMWATER
FROM TEMP SEDIMENT
SETTLEMENT TANKS TO EXISTING
CATCH BASIN. CONTRACTOR TO
ENSURE ALL DISCHARGE MEETS
TURBIDITY REQUIREMENTS
(1) 18,900 GALLON CAPACITY
TEMPORARY SEDIMENT SETTLEMENT
TANK ("BAKER TANK" OR EQUAL).
CONTRACTOR SHALL PROVIDE ALL
PUMPS REQUIRED TO MANAGE
CONSTRUCTION STORMWATER AND
DISCHARGE AT THE SITE
PROTECT EX
SHED TO REMAIN
REMOVE FENCE AS
NEEDED FOR STORM
INSTALLATION
EX DOUBLE SWING VEHICLE
GATE FOR CONSTRUCTION
ACCESS TO SITE
EX ASPHALT
ACCESS DRIVE
FF
REMOVE EX
TREE CLUSTER
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
DEMOLITION AND TESC PLAN
SEE SHEET C001 FOR CITY OF RENTON
ESC STANDARD PLAN NOTES
SEE SHEET C102 FOR TESC
CONSTRUCTION SEQUENCE NOTES
LEGEND
MATCHLINE - SEE SHEET C107
CHURCH PROPERTY
NO CONSTRUCTION
ACCESS TO THIS PARCEL
FOR WORK IN THE
RIGHT-OF-WAY
SEE SHEET C109
IMPROVED SOFTBALL FIELD.
SEE LANDSCAPE PLANS
AND CIVIL SHEET C205
CONSTRUCTION FENCING NOTE:
INSTALL CONSTRUCTION FENCING
AROUND LIMITS OF WORK TO PROTECT
STAFF AND STUDENTS AND SECURE
JOBSITE. CONTRACTOR SHALL ERECT FENCE
AROUND JOBSITE AND ADJUST AS
CONSTRUCTION CONDITIONS CHANGE OR
AS PHASING ALLOWS. CONTRACTOR CAN
UTILIZE EXISTING PERIMETER FENCING AS
SECURITY FENCING AND THEN
SUPPLEMENT ON THE WEST SIDE OF THE
SITE AS NEEDED. ANY EXISTING CHAINLINK
FENCING THE CONTRACTOR ELECTS TO
UTILIZE DURING CONSTRUCTION SHALL
APPLY (IE ZIPTIES OR OTHER MEANS) HIGH
VISIBILITY MATERIAL OR SIMILAR METHOD
TO BE APPLIED TO FENCING TO DELINEAT
AS CONSTRUCTION ZONE (TYP). ANY
SECTIONS OF EXISTING FENCING THAT IS
NOT 6-FT HIGH SHALL HAVE TEMPORARY
6-FT HIGH CHAINLINK FENCING INSTALLED
NEXT TO IT. SEE DETAIL 10/C110.
SAWCUT LINE
REMOVE CURBING
REMOVE ASPHALT PAVEMENT
REMOVE CONCRETE PAVEMENT
TREE PROTECTION
INLET PROTECTION
PROPERTY LINE
CF
IP
VEG
BOTTOM OF EXCAVATION
SILT FENCEFF
INTERCEPTOR SWALEIS
TEMP CONSTRUCTION
FENCING
R-432608
TE
D
-
4
0
-
4
3
2
6
R-432608
DEVELOPMENT ENGINEERING
msippo 08/07/2025
SW
SW
SW
SW
SW
SW
PROTECT EX VAULT ACCESS HATCH;
IF OPEN GRATING, CONTRACTOR
SHALL COVER WITH FABRIC AND OR
PVC LINER AND TIE DOWN TO
PROTECT VAULT OPENING
SAWCUT AND REMOVE EX CONCRETE
PAVEMENT AS REQUIRED TO
CONSTRUCT NEW 6" CONCRETE PAD
FOR FUTURE GREENHOUSE.
SEE SHEET C206
INSTALL STRAW WATTLES
SEE DETAIL (TYP)
C110
8
EXISTING IRRIGATION LINE.
CONTRACTOR TO CONFIRM AND
SHALL POTHOLE AND CONFIRM
LOCATION, DEPTH, AND MATERIAL
PROTECT EXISTING
WATER SPIGOT ON
BUILDING
EXISTING DILUTION TRAP
TO BE DEMOLISHED
EXISTING 10"
SEWER LINE TO
REMAIN
EXISTING 10" STORM
PIPE TO REMAIN
EXISTING 6" ACID WASTE LINE
TO BE ABANDONED CUT AND
CAP AND FILL WITH CDF PER
PROJECT SPECIFICATIONS
EXISTING ACID WASTE
LINE TO BE BUILDING
TO BE ABANDONED.
CUT & CAP EXISTING
ACID WASTE LINE TO
BE BUILDING TO BE
ABANDONED
CUT AND CAP EXISTING
ACID WASTE LINE TO BE
BUILDING TO BE
ABANDONED
REMOVE EX 6"
DECIDUOUS TREE
IP
VEG
REMOVE EX 5"
DECIDUOUS TREE
INSTALL TREE
PROTECTION FENCING
SEE DETAIL
IP
IP
INSTALL CB
PROTECTION
SEE DETAIL (TYP)
C110
7
PROTECT EXISTING 2"
IRRIGATION LINE TO REMAIN
REMOVE EX
SEWER CLEANOUT
SAWCUT AND DEMO EX
CONCRETE PAVEMENT TO CUT,
CAP, AND ABANDON-IN-PLACE
EX ACID WASTE PIPING (TYP)CUT AND CAP EXISTING ACID
WASTE LINE TO BE BUILDING
TO BE ABANDONED
CUT, CAP, AND REMOVE
PORTION OF EX SEWER
PIPE TO BE REPLACED.
SEE SHEET C206
SAWCUT AND DEMO EX
CONCRETE PAVEMENT TO CUT,
CAP, AND ABANDON-IN-PLACE
EX ACID WASTE PIPING (TYP)
REMOVE EX 8"
DECIDUOUS TREE
C111
10
LOCATION OF ECO PAN FOR
CONCRETE PUMPER TRUCK
WASHOUT LOCATED EAST IN
PARKING LOT. SEE SHEET C010.
2'
2'
CONTRACTOR SHALL MAKE A
RECORD OF EXISTING
SCORE/JOINT LINES FOR COURTYARD
TO BE MATCHED FOR FINISHED
CONCRETE CONDITION. (TYP)
DEMOLISH AND REMOVE EX SECURITY
FENCING AND GATES, INCLUDING ANY
HARDWARE, OUTSIDE THE GYM/CAFETERIA
AREA COURTYARD. CONTRACTOR SHALL
SAWCUT 2' AROUND POSTS AND REMOVE
POSTS. PROTECT ALL UTILITIES AND
APPURTANCES IN THIS AREA TO REMAIN.
SAWCUT AND REMOVE EX
CONCRETE PAVEMENT FOR
FENCE AND POST REMOVAL
DEMOLITION AND TESC PLAN
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
SCALE 1"=10'
5 10 200
HAZEN HIGH SCHOOL MODERNIZATION
DEMOLITION AND TESC PLAN
SEE SHEET C001 FOR CITY OF RENTON
ESC STANDARD PLAN NOTES
SEE SHEET C102 FOR TESC
CONSTRUCTION SEQUENCE NOTES
LEGEND
SAWCUT LINE
REMOVE CURBING
REMOVE ASPHALT PAVEMENT
REMOVE CONCRETE PAVEMENT
TREE PROTECTION
INLET PROTECTION
PROPERTY LINE
TEMP CONSTRUCTION FENCINGCF
IP
VEG
CONSTRUCTION FENCING NOTE:
INSTALL CONSTRUCTION FENCING AROUND LIMITS OF
WORK TO PROTECT STAFF AND STUDENTS AND SECURE
JOBSITE. CONTRACTOR SHALL ERECT FENCE AROUND
JOBSITE AND ADJUST AS CONSTRUCTION CONDITIONS
CHANGE OR AS PHASING ALLOWS. CONTRACTOR CAN
UTILIZE EXISTING PERIMETER FENCING AS SECURITY
FENCING AND THEN SUPPLEMENT ON THE WEST SIDE OF
THE SITE AS NEEDED. ANY EXISTING CHAINLINK FENCING
THE CONTRACTOR ELECTS TO UTILIZE DURING
CONSTRUCTION SHALL APPLY (IE ZIPTIES OR OTHER MEANS)
HIGH VISIBILITY MATERIAL OR SIMILAR METHOD TO BE
APPLIED TO FENCING TO DELINEAT AS CONSTRUCTION ZONE
(TYP). ANY SECTIONS OF EXISTING FENCING THAT IS NOT
6-FT HIGH SHALL HAVE TEMPORARY 6-FT HIGH CHAINLINK
FENCING INSTALLED NEXT TO IT. SEE DETAIL 10/C110.
STRAW WATTLESSW SW
R-432609
TE
D
-
4
0
-
4
3
2
6
R-432609
DEVELOPMENT ENGINEERING
msippo 08/07/2025
□
□
□
IP
INSTALL CB PROTECTION
SEE DETAIL (TYP)
C110
7
FF
IP
IP
INSTALL CB PROTECTION
SEE DETAIL (TYP)
C110
7
S
W
SW
SW
SW
REMOVE ALL (5) EX. 24" CONCRETE
BOLLARDS AND SURROUNDING
PAVING (TYP.) THE EXTENTS IS
APPROXIMATE AND WILL BE ADJUSTED
WHEN SURVEYED JOINT LINES ARE
RECEIVED. SEE SHEET C207
INSTALL STRAW
WATTLES
SEE DETAIL (TYP)
C110
8
PROTECT EX
CONCRETE CURB
TO REMAIN (TYP)
4'
IP
REMOVE/RELOCATE EX "POOL
PARKING ONLY" SIGN AND POST FOR
INSTALLATION OF NEW TEMPORARY
PORTABLE BUILDINGS.
SEE SHEET C207
BOE = 470.50
APPROXIMATE LIMITS OF PROPOSED
DETENTION SYSTEM EXCAVATION FOR
SOFTBALL FIELD. SEE SHEET C205
DECOMMISSION EX BELOW GRADE 10,000 GAL. FUEL OIL TANK.
COORDINATE W/ PBS ENVIRONMENTAL FOR DECOMMISSIONING
AND SEQUENCING PROCEDURES TANK EXTENTS UNKNOWN AND
ARE SHOWN AS APPROXIMATE TO BE DETERMINED IN FIELD. CUT,
CAP, AND ABANDON-IN-PLACE ANY FUEL OIL PIPING CONNECTED
TO EX FUEL OIL TANK. EX TANK TO BE PUMPED OUT, CLEANED,
AND FILLED WITH A CONCRETE SLURRY AND THEN
ABANDONED-IN-PLACE. CITY TO RECEIVE DOCUMENTATION OF
DECOMMISSIONING AND ABANDONMENT PRIOR TO CIVIL
CONSTRUCTION PERMIT CLOSE-OUT.
IP
REMOVE (2) EX
DECIDUOUS TREES
IP
IP
IP
IP IP
HO
Q
U
I
U
M
A
V
E
.
N
.
E
.
(A
D
E
D
I
C
A
T
E
D
P
U
B
L
I
C
R
I
G
H
T
O
F
W
A
Y
)
PROTECT EX
SYNTHETIC GRASS
SURFACING
VEG
VEG
IP
IPIP
IP
IP
SAWCUT TO NEAREST
SIDEWALK JOINT (TYP)
1.5'
IP
CONTRACTOR TO UTILIZE
4' MAX VERTICAL CUT AT
BOTTOM OF EXCAVATION
475
476
477
475
476
477
EXISTING 10" WATER MAIN TO BE PROTECTED AT ALL TIMES.
PROTECTION SHALL INCLUDE, BUT NOT LIMITED TO,
PROHIBITION OF HEAVY MACHINERY AND DRILLING
EQUIPMENT ON TOP OF MAIN OR WITHIN EASEMENT.
VIBRATIONAL TESTING MAY BE REQUIRED FOR ANY DRILLING
OR PILING OCCURRING NEAR THE MAIN. ADDITIONALLY, ANY
MACHINERY CROSSING THE WATER MAIN IN UNPAVED AREAS
WILL BE REQUIRED SHEETING OR SIMILAR MECHANISM TO
ENSURE THAT THE MAIN IS NOT SUBJECT TO DAMAGE LOADS.
CONTRACTOR SHALL USE
CAUTION WHEN PERFORMING
CONSTRUCTION NEAR OR OVER
EXISTING CHARGED WATERMAIN
PROTECT EX CURB
TO REMAIN
PROTECT EX
SECURITY CAMERA
EX GENERATOR TO
BE RELOCATED
PER ELEC'L PLANS
EX TRANSFORMER
TO BE RELOCATED
REMOVE EX
CHAINLINK FENCE
AND GATE
SAWCUT AT NEAREST JOINT
AND REMOVE EX CONCRETE
EXTRUDED CURB
SAWCUT AND REMOVE EX
ASPHALT PAVEMENT AS NEEDED
TO INSTALL NEW CHAINLINK
FENCE AND EXTRUDED CURB
SEE SHEET C207 (TYP)
REMOVE EX SHRUBS WITHIN
ENCLOSED AREA TO INSTALL
CRUSHED ROCK SURFACING
SEE SHEET C207
PROTECT (2) EX 2" GAS
VENTS TO REMAIN
PROTECT EX
CONCRETE PAD
TO REMAINPROTECT EX LIGHT
POLE TO REMAIN
SALVAGE AND REMOVE
EX SHRUBS AND
LANDSCAPING IN
PLANTER AS NEEDED
REMOVE EX CONCRETE
VERTICAL CURB AS
REQUIRED TO INSTALL NEW
FIRE HYDRANT ASSEMBLY
SAWCUT AND
REMOVE EX ASPHALT
REMOVE EX GATE HITCH
ECO PAN FOR CONCRETE
TRUCK CLEANOUT; FINAL
LOCATION TO BE
COORDINATED IN FIELD
DURING CONSTRUCTION.
IS
SALVAGE AND REMOVE EX
LIGHT POLE AND BASE TO BE
REINSTALLED AT
COMPLETION OF PROJECT
VEG
2'2'
CONTRACTOR SHALL MAKE
A RECORD OF EXISTING
SCORE/JOINT LINES FOR
COURTYARD TO BE
MATCHED FOR FINISHED
CONCRETE CONDITION. (TYP)
SAWCUT AND REMOVE EX
CONCRETE PAVEMENT
FOR FENCE AND POST
REMOVAL
DEMOLISH AND REMOVE EX SECURITY
FENCING AND GATES, INCLUDING ANY
HARDWARE, OUTSIDE THE GYM/CAFETERIA
AREA COURTYARD. CONTRACTOR SHALL
SAWCUT 2' AROUND POSTS AND REMOVE POSTS.
PROTECT ALL UTILITIES (I.E. TRENCH DRAIN) AND
APPURTANCES IN THIS AREA TO REMAIN.
VEG
SW
SW
SW
SW
SW
SW
SW
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
DEMOLITION AND TESC PLAN
SEE SHEET C001 FOR CITY OF RENTON
ESC STANDARD PLAN NOTES
SEE SHEET C102 FOR TESC
CONSTRUCTION SEQUENCE NOTES
LEGEND
SAWCUT LINE
REMOVE CURBING
REMOVE ASPHALT PAVEMENT
REMOVE CONCRETE PAVEMENT
TREE PROTECTION
INLET PROTECTION
PROPERTY LINE
TEMP CONSTRUCTION FENCINGCF
IP
VEG
MATCHLINE - SEE SHEET C105
CHURCH PROPERTY
NO CONSTRUCTION
ACCESS TO THIS PARCEL
IMPROVED SOFTBALL FIELD.
SEE LANDSCAPE PLANS
AND CIVIL SHEET C207
CONSTRUCTION FENCING NOTE:
INSTALL CONSTRUCTION FENCING AROUND
LIMITS OF WORK TO PROTECT STAFF AND
STUDENTS AND SECURE JOBSITE.
CONTRACTOR SHALL ERECT FENCE AROUND
JOBSITE AND ADJUST AS CONSTRUCTION
CONDITIONS CHANGE OR AS PHASING
ALLOWS. CONTRACTOR CAN UTILIZE
EXISTING PERIMETER FENCING AS SECURITY
FENCING AND THEN SUPPLEMENT ON THE
WEST SIDE OF THE SITE AS NEEDED. ANY
EXISTING CHAINLINK FENCING THE
CONTRACTOR ELECTS TO UTILIZE DURING
CONSTRUCTION SHALL APPLY (IE ZIPTIES
OR OTHER MEANS) HIGH VISIBILITY
MATERIAL OR SIMILAR METHOD TO BE
APPLIED TO FENCING TO DELINEAT AS
CONSTRUCTION ZONE (TYP). ANY SECTIONS
OF EXISTING FENCING THAT IS NOT 6-FT
HIGH SHALL HAVE TEMPORARY 6-FT HIGH
CHAINLINK FENCING INSTALLED NEXT TO
IT. SEE DETAIL 10/C110.
R-432610
TE
D
-
4
0
-
4
3
2
6
R-432610
DEVELOPMENT ENGINEERING
msippo 08/07/2025
REMOVE AND REINSTALL
STOP SIGN FOR
SIDEWALK INSTALLATION
SAWCUT AND REMOVE EXISTING
CONCRETE DRIVEWAY, SIDEWALK
AND ASPHALT AS REQUIRED TO
INSTALL NEW CURB CUT AND STORM
PIPE. SEE SHEETS C010 & C207
SAWCUT TO NEAREST
SIDEWALK JOINT (TYP)
1.5'
IP
IP
SAWCUT TO NEAREST
SIDEWALK JOINT (TYP)
1.5'
SAWCUT AND REMOVE EXISTING
CONCRETE DRIVEWAY, SIDEWALK
AND ASPHALT AS REQUIRED TO
INSTALL NEW CURB CUT AND STORM
PIPE. SEE SHEETS C010 & C207
HOQUIAM AVE. N.E.
SWSWSWSWSWSWSW
N.
E
.
11
T
H
S
T
PROTECT
EX SIGN
PROTECT
EX SIGN
PROTECT
EX SIGN
N.
E
.
10
T
H
P
L
IP
IP
22+00 23+00 24+00 25+00 26+00 27+00
22+50 23+50 24+50 25+50 26+50
SW
INSTALL CB
PROTECTION
SEE DETAIL (TYP)
1.5'IP SW 1.5'
SAWCUT TO NEAREST
SIDEWALK JOINT (TYP)
SAWCUT AND REMOVE
EXISTING CONCRETE
DRIVEWAY, SIDEWALK AND
ASPHALT AS REQUIRED TO
INSTALL NEW CURB CUT.
SEE SHEETS C010 & C201
HOQUIAM AVE. N.E.C110
7
SWSWSW
SWSWSWSWINSTALL STRAW
WATTLES
SEE DETAIL (TYP)
C110
8SAWCUT AND
REMOVE EX
ASPHALT RAMP
N.
E
.
12
T
H
S
T
N.
E
.
11
T
H
P
L
N.
E
.
11
T
H
C
T
VEG
PROTECT EX
MANHOLE
PROTECT
EX SIGN
REMOVE EX
THERMOPLASTIC
CROSSWALK
28+00 29+00 30+00 31+00 32+00 33+00 33+18
27+50 28+50 29+50 30+50 31+50 32+50
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
HOQUIAM AVE NE DEMOLITION AND TESC PLAN
TREE PROTECTION
INLET PROTECTION
PROPERTY LINE
TEMP CONSTRUCTION FENCINGCF
IP
VEG
SAWCUT LINE
REMOVE CURBING
REMOVE ASPHALT PAVEMENT
REMOVE CONCRETE PAVEMENT
REMOVE TREE(S)
MA
T
C
H
L
I
N
E
-
S
E
E
A
B
O
V
E
R
I
G
H
T
MA
T
C
H
L
I
N
E
-
S
E
E
B
E
L
O
W
L
E
F
T
REMOVE EX "SCHOOL
CROSSING" AND "LEFT
ARROW" SIGNS AND POST.
SEE SHEET C208.
PROTECT EX " STOP" SIGN
AND POST TO REMAIN
SAWCUT AND REMOVE EXISTING
CONCRETE DRIVEWAY, SIDEWALK
AND ASPHALT AS REQUIRED TO
INSTALL NEW CURB CUT. SEE
SHEETS C010 AND C201
PROTECT EX TREE ON
PRIVATE PROPERTY
SAWCUT AND REMOVE EX
CONCRETE AND ASPHALT AS
REQUIRED TO REPLACE EX
CURB RAMP. SEE SHEET C208.
PROTECT EX UTILITY
POLE AND GUY WIRE
REMOVE EX "SCHOOL
CROSSING" AND "LEFT
ARROW" SIGNS AND POST.
SEE SHEET C208.
SAWCUT TO NEAREST
SIDEWALK JOIN (TYP)
PROTECT EX SIGN REMOVE EX CATCH
BASIN TO BE REPLACED
R-432611
TE
D
-
4
0
-
4
3
2
6
R-432611
DEVELOPMENT ENGINEERING
msippo 08/07/2025
N.E. 10TH ST.
FI
E
L
D
AV
E
N
.
E
.
EXISTING STREET LIGHT, POLE, AND
POLE BASE, TO BE REMOVED. PROTECT
EX HANDHOLE AND CONCRETE PAD TO
REMAIN. SEE ELECTRICAL PLANS.
ADJUST HANDHOLE TO PROPOSED
FINISHED GRADE. SEE SHEET C209
EX WATER DISTRICT
90 WATER MAIN
REMOVE FENCE AS
NEEDED FOR STORM
INSTALLATION
PROTECT EX STORM
PROTECT EX SEWER
PROTECT EX
FIRE HYDRANT
REMOVE EX
GUARDRAIL
FF
INSTALL FILTER
FENCE (TYP)
SEE DETAIL C111
9FF
IP
IP
PROTECT
EX CB
REMOVE EX CLUSTER TREE
THAT WILL BE IMPACTED BY
NEW GRADING AND
IMPROVEMENTS FOR NE 10TH
STREET. SEE SHEET C209
PROTECT EX CHAINLINK
FENCE TO REMAIN
3+00 4+00 5+00 6+00 7+00 8+00
3+50 4+50 5+50 6+50 7+50 8+50
N.E. 10TH ST.
1.5'
SAWCUT AND REMOVE EXISTING
CONCRETE ADA RAMP TO BE
UPGRADED TO MEET ACCESSIBILITY
REQUIREMENTS
SAWCUT TO NEAREST
SIDEWALK JOINT (TYP)
SAWCUT AND REMOVE EXISTING
CONCRETE DRIVEWAY, SIDEWALK
AND ASPHALT AS REQUIRED TO
INSTALL NEW DRIVEWAY
SAWCUT TO NEAREST
SIDEWALK JOINT (TYP)
SWSWSW
1.5'
SW
GR
A
H
A
M
AV
E
N
.
E
.
HO
Q
U
I
A
M
AV
E
N
.
E
.
IPIP
INSTALL CB
PROTECTION
SEE DETAIL (TYP)
C110
7
INSTALL STRAW
WATTLES
SEE DETAIL (TYP)
C110
8
IP
IP
IP
IP
IP
9+00 10+00 11+00 12+00 13+00
9+50 10+50 11+50 12+50 13+5020
+
0
0
20
+
5
0
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
NE 10TH ST DEMOLITION AND TESC PLAN
TREE PROTECTION
INLET PROTECTION
PROPERTY LINE
TEMP CONSTRUCTION FENCINGCF
IP
VEG
SAWCUT LINE
REMOVE CURBING
REMOVE ASPHALT PAVEMENT
REMOVE CONCRETE PAVEMENT
REMOVE TREE(S)
MA
T
C
H
L
I
N
E
-
S
E
E
A
B
O
V
E
R
I
G
H
T
MA
T
C
H
L
I
N
E
-
S
E
E
B
E
L
O
W
L
E
F
T
FOR SITE DEMOLITION AND
TESC SCOPE, REFERENCE SHEET
C105 FOR WORK IN THIS AREA
FOR SITE DEMOLITION AND
TESC SCOPE, REFERENCE SHEET
C105 FOR WORK IN THIS AREA
PROTECT EX ELECTRICAL CONDUIT(S) THAT
SERVICE EX LIGHT POLE TO BE RE-USED FOR
POWER POC / TIE-IN FOR NEW STREET
LIGHTING. SEE SHEET C209. CONTRACTOR
SHALL POTHOLE AND VERIFY LOCATION, DEPTH,
AND MATERIAL OF EXISTING ELECTRICAL
CONDUITS PRIOR TO STARTING CONSTRUCTION
REMOVE EX GATE AND THEN
SAWCUT AND REMOVE EX
CONCRETE DRIVEWAY CURB
CUT, INCLUDING CURB AND
ASPHALT AS REQUIRED
R-432612
FILTER FABRIC FENCINGFF
TE
D
-
4
0
-
4
3
2
6
R-432612
DEVELOPMENT ENGINEERING
msippo 08/07/2025
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
TESC DETAILS
6'
F
E
N
C
E
LINE POST (TYP)
2.375 INCH 0.D.
TOP RAIL
1.666 INCH O.D.
STRETCHER
BAR
BRACE RAIL
AND CABLE
1.666 INCH O.D.
TRUSS ROD 3/8" DIA
W/ TENSION DEVICE
TENSION WIRE
CONCRETE BLOCK
STD WGT GALVANIZED
CORNER POST
5/8" WIRE ROPE PROVIDE SECURE
END ATTACHMENT AT CORNER AND
GATE POSTS AND PROVIDE RUNNING
ATTACHMENT AT LINE POSTS AND
NEAR CENTER OF EACH FENCE PANEL
Inlet Protection 7NTS
Straw Wattle 8NTS
Construction Fence 10NTS
Check Dams 6NTS
Construction Entrance 5NTS
Not Used 9NTS
R-432613
TE
D
-
4
0
-
4
3
2
6
R-432613
DEVELOPMENT ENGINEERING
msippo 08/07/2025
BASEBALL DETENTION EXCAVATION SECTION
SCALE: 1" = 20'
420
440
460
480
420
440
460
480
X
X
EXISTING GRADE
1:1 MAX CUT SLOPE
4' VERTICAL
CUT
BOE 442.50
PROTECT EX
FENCE AND
SYNTHETIC TURF
2'
6" GRAVEL BASE PER
STORMTRAP SPECS
SEE PAGES C314 AND
#### FOR DETENTION
VAULT DETAILS
4' VERTICAL CUT
SOFTBALL DETENTION EXCAVATION SECTION
SCALE: 1" = 20'
440
460
480
500
440
460
480
500
EXISTING GRADE
1:1 MAX CUT SLOPE
4' VERTICAL CUT
BOE 469.501'
9" GRAVEL BASE
SEE PAGE C314 FOR
DETENTION VAULT
DETAILS
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
TESC DETAILS
Temporary Sump and Pump 8NTS
Silt Fence 9NTS
Interceptor Swale 5NTS
10'TENSAR GS-1 SAFETY
FENCE OR EQUAL
GALVANIZED WIRE OR
OTHER APPROVED
MATERIAL
STEEL FENCE POST
CLIP FENCE TO WIRE
WIRE FENCE
TO STEEL POST
Clearing Limits Fence 6NTS
Section A 31"=20'
Section B 41"=20'
Tree Protection Fence 10NTS
R-432614
TE
D
-
4
0
-
4
3
2
6
6"=12" PERFORATE
PIPE AS NECESSARY
TOP OF PIPE SHALL BE
6" MIN ABOVE GRADE
PROVIDE SOLID COVER
2.
9
'
WATER LEVEL CONCRETE BLOCKS
SUMP PUMP AND MOTOR
WIRE TIES
55 GALLON DRUM W/ 2"
DIA WEEP HOLES OR
APPROVED EQUAL
WRAP WITH PERMEABLE
FILTER FABRIC
PROVIDE 12" MIN
WASHED ROCK AROUND
PERIMETER OF PIPE
2'
1'
2'
MATCH EXISTING
DI
S
C
H
A
R
G
E
DI
S
C
H
A
R
G
E
5'
FILTERED
RUNOFF
WATER LEVEL
2'
RUNOFF WITH
SEDIMENT
MATCH EXISTING
3
1
3
1
R-432614
DEVELOPMENT ENGINEERING
msippo 08/07/2025
HO
Q
U
I
A
M
A
V
E
.
N
.
E
.
(A
D
E
D
I
C
A
T
E
D
P
U
B
L
I
C
R
I
G
H
T
O
F
W
A
Y
)
SD
SD
SD SD
E E E E E
E
E
NEW SECURITY ENTRY
VESTIBULE PER ARCH'L
AND STRUCT'L PLANS
NEW TRAFFIC
RATED BOLLARDS
6'
FF=468.13
REINSTALL SALVAGED
BOLT DOWN BENCH
PROTECT EX STORM
CLEANOUT CASTING TO
REMAIN. ADJUST CASTING
TO FINISH GRADE
PROTECT EX
BUILDING COLUMN
TO REMAIN
REINSTALL SALVAGED
BOLT DOWN BENCH
MATCH EX
CONCRETE (TYP)
468.10
468.11
468.11
468.11
468.13
468.13
CONTRACTOR SHALL MAKE A
RECORD OF EXISTING
SCORE/JOINT LINES TO BE
MATCHED FOR FINISHED
CONCRETE CONDITION. (TYP)
EX BUILDING
OVERHANG/CANOPY
ABOVE (TYP)
CONCRETE PLAZA
SIDEWALK
SEE DETAIL C300
3
NEW NON-REMOVEABLE HEAVY
DUTY VEHICULAR RATED
SECURITY BOLLARD (TYP
UNLESS OTHERWISE NOTED)
SEE DETAIL
C301
6
1.3' (TYP)
INSTALL NEW REMOVEABLE
HEAVY DUTY VEHICULAR RATED
SECURITY BOLLARD (2 TOTAL)
SEE DETAIL
C301
10
RESTORE CONCRETE
SIDEWALK
SEE DETAIL (TYP)
C300
3
1.3' (TYP)
REINSTALL ADA
PARKING SIGN
AND POST
REINSTALL ADA
PARKING SIGN
AND POST
CONTRACTOR SHALL MAKE A
RECORD OF EXISTING
SCORE/JOINT LINES TO BE
MATCHED FOR FINISHED
CONCRETE CONDITION. (TYP)
0.8' (TYP)
6'7.6'
(TYP U.O.N.)
6'
467.72 0.8' (TYP)
REINSTALL BUS
LOADING SIGN
AND POST
5'
CANOPY PER
ARCH'L PLANS
C312
9
DS
DS
45° BEND
IE 465.60
CONNECT NEW
4" SD TO EX CB
IE 465.53
4"x4" TEE
IE 465.98
DOWNSPOUT CONNECTION
IE 466.10
SEE DETAIL (TYP)
33 LF 4"
PVC @ 1.7%
28 LF 4"
PVC @ 1.9%
DOWNSPOUT
CONNECTION
IE 466.50
468.07
467.99 (EX)467.95 (EX)467.92 (EX)
467.82 (EX)
467.72 (EX)
467.66 (EX)
467.63 (EX)
467.59 (EX)
467.55 (EX)
467.41 (EX)
468
REMOVE AND REINSTALL
EX "STOP" SIGN AND POST
467.97
467.91
REPLACE EX ACCESSIBLE
RAMP WITH NEW
PERPENDICULAR CURB RAMP
SEE DETAIL
C302
9467.41
467.40
STANDARD DUTY
ASPHALT RESTORATION
SEE DETAIL
C300
7
6.
3
'
6.
2
'
(
T
Y
P
U
.
O
.
N
.
)
6
'
40
'
6'
7.7'
BOLLARD DEPTH IS 30" DEEP BY 16" WIDE.
CONTRACTOR SHALL USE CAUTION WHEN
PERFORMING CONSTRUCTION NEAR OR OVER
EXISTING CHARGED WATERMAIN.
SECURITY BOLLARDS SHALL NOT BE PLACED
OVER EXISTING 10" COR WATERMAIN.
BOLLARDS WITH FOUNDATION SHALL BE A
MINIMUM OF 5' FROM THE EXISTING 10"
WATER MAIN
SEE DETAIL
C301
6
EXISTING 10" WATER MAIN TO BE PROTECTED AT ALL TIMES.
PROTECTION SHALL INCLUDE, BUT NOT LIMITED TO, PROHIBITION OF
HEAVY MACHINERY AND DRILLING EQUIPMENT ON TOP OF MAIN OR
WITHIN EASEMENT. VIBRATIONAL TESTING MAY BE REQUIRED FOR
ANY DRILLING OR PILING OCCURRING NEAR THE MAIN. ADDITIONALLY,
ANY MACHINERY CROSSING THE WATER MAIN IN UNPAVED AREAS
WILL BE REQUIRED TO UTILIZE SHEETING OR SIMILAR MECHANISM TO
ENSURE THAT THE MAIN IS NOT SUBJECT TO DAMAGE LOADS.
ECO PAN FOR CONCRETE TRUCK
CLEANOUT; FINAL LOCATION TO
BE COORDINATED IN FIELD
DURING CONSTRUCTION.
468
469
470
7'
467.94 (EX)
467.94 (EX)
467.84 (EX)
467.89 (EX)
467.56 (EX)
467.51 (EX)
467.43 (EX)
467.46 (EX)
467.47 (EX)
467.54 (EX)
467.54 (EX)
467.95 (EX)
468.02 (EX)
469.29 (EX)
469.40 (EX)
469.77 (EX)
8.
7
'
5'
MIN
5'
MIN
EX 10"
WATERMAIN
28
+
0
0
29
+
0
0
27
+
5
0
28
+
5
0
NEW NON-REMOVEABLE HEAVY
DUTY VEHICULAR RATED
SECURITY BOLLARD (TYP
UNLESS OTHERWISE NOTED)
SEE DETAIL
C301
6
4'
9.
8
'
4.6'
3'
17
.
7
'
8'
INSTALL NEW REMOVEABLE
HEAVY DUTY VEHICULAR RATED
SECURITY BOLLARD (2 TOTAL)
(FINAL BOLLARD LAYOUT TBD)
SEE DETAIL
C301
10
8'
3'
16
.
4
'
0.8' (TYP)
6.
7
'
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
PROPERTY LINE
CONTOUR (INDEX)
CONTOUR
GRADE BREAK
SPOT ELEVATION
110
109.36
109
TC 109.86
BC 109.36
ASPHALT PAVEMENT
CONCRETE CURB
CONCRETE PAVEMENT
SCALE 1"=10'
5 10 200
HAZEN HIGH SCHOOL MODERNIZATION
CIVIL SITE PLAN
CONTINUATION - SEE TOP RIGHT
CONTINUATION - SEE BOTTOM LEFT
PROTECT EX
CONCRETE CROSSING
AND CROSSWALK
STRIPING TO REMAIN
RESTORE CONCRETE
SIDEWALK
SEE DETAIL (TYP)
C300
3
BUILDING VESTIBULE
FOR WORK IN THE
RIGHT-OF-WAY
SEE SHEET C208
NOTE:
FOR ALL EXTERIOR CONCRETE PAVEMENT,
PROVIDE SPRAY-LOCK P3 OR EQUAL CONCRETE
PAVING SURFACE TREATMENT TO HELP PROTECT
CONCRETE AGAINST WINTER DE-ICING SALT PER
PROJECT SPECIFICATION SECTION 321313.23
R-432615
TE
D
-
4
0
-
4
3
2
6
R-432615
DEVELOPMENT ENGINEERING
msippo 08/07/2025
□
SUB
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
FOR RESTORATION OF PRACTICE
FIELD NORTH OF BASEBALL
FIELD, SEE LANDSCAPE PLANS
EXISTING 10" WATER MAIN TO BE PROTECTED AT ALL TIMES.
PROTECTION SHALL INCLUDE, BUT NOT LIMITED TO,
PROHIBITION OF HEAVY MACHINERY AND DRILLING EQUIPMENT
ON TOP OF MAIN OR WITHIN EASEMENT. VIBRATIONAL TESTING
MAY BE REQUIRED FOR ANY DRILLING OR PILING OCCURRING
NEAR THE MAIN. ADDITIONALLY, ANY MACHINERY CROSSING
THE WATER MAIN IN UNPAVED AREAS WILL BE REQUIRED TO
UTILIZE SHEETING OR SIMILAR MECHANISM TO ENSURE THAT
THE MAIN IS NOT SUBJECT TO DAMAGE LOADS.
ADJUST RIM TO GRADE AS REQUIRED.
CONTRACTOR SHALL ADJUST PROPOSED
GROUND SOURCE WELL AS REQUIRED TO
AVOID CONFLICTS WITH EXISTING CATCH
BASINS AND BELOW GRADE STORM PIPING
ON EAST SIDE OF PRACTICE FIELD
PROTECT EX 4"
STORM DRAIN
PIPING TO REMAIN
FINISHED GRADE OF EXISTING PRACTICE
FIELD WILL MATCH EXISTING GRADE AND
IS NOT PLANNED TO BE REGRADED AFTER
INSTALLATION OF GROUND SOURCE WELL
FIELD AND ASSOCIATED PIPING.
ADJUST RIM TO
GRADE AS REQUIRED
PROVIDE 18" MINIMUM VERTICAL
CLEARANCE FROM 4" FIRE SERVICE
LINE AND NEW ELECTRICAL LINE.
ELECTRICAL LINE SHALL ROUTE
UNDERNEATH FIRE SERVICE LINE.
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
PROPERTY LINE
CONTOUR (INDEX)
CONTOUR
GRADE BREAK
SPOT ELEVATION
110
109.36
109
TC 109.86
BC 109.36
ASPHALT PAVEMENT
CONCRETE CURB
CONCRETE PAVEMENT
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
CIVIL SITE PLAN
MATCHLINE - SEE SHEET C203
SUMP PUMP NOTES
1.PROVIDE MINIMUM 16" ROUND OR SQUARE x 8" DEEP SUMP WITH ZOELLER MODEL
57 SUMP PUMP WITH SOLID BUOYANT POLYPROPYLENE FLOAT. FOR POWER
REQUIREMENTS, SEE DETAIL 5/C311.
2.PROVIDE ELECTRICAL POWER TO VAULT AND WITHIN 4' MIN TO 6' MAX VERTICAL
DISTANCE AND 1' MAX HORIZONTAL DISTANCE TO SUMP PUMP PER ALL APPLICABLE
CODES.
3.CONSTRUCT 4" MIN SCHED 80 PVC DISCHARGE PIPING WITH LOCATE WIRE TO
NEAREST CATCH BASIN AS INDICATED ON PLAN. PROVIDE "LINK SEAL" FITTING AT
PIPE PENETRATION. TERMINATE LOCATE WIRE INSIDE OF VAULT, 6" FROM LINK-SEAL.
4.DISCHARGE PIPING SHALL BE ATTACHED TO THE INTERIOR VAULT WALL WITH
APPROVED FASTENERS AT 3' SPACING.
5.INSTALL A QUICK DISCONNECT COUPLING, CHECK VALVE, AND ISOLATION BALL
VALVE ON DISCHARGE PIPING IMMEDIATELY AFTER SUMP PUMP. SEE DETAIL 8/C311
6.PROVIDE NEMA-4X RECEPTACLE AT ELEVATION REQUIRED TO CONNECT PUMP.
7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ELECTRICAL PERMITS AND
APPROVALS FOR SUMP PUMP INSTALLATIONS.
1.ALL JOINTS FOR MODULES ARE MADE SOIL-TIGHT WHEN APPLIED WITH JOINT TAPE (7/8” DIAMETER
PREFORMED BUTYL JOINT SEALER) AND JOINT WRAP (8” WIDE SELF-ADHESIVE ELASTOMERIC RESIN BONDED
WOVEN PUNCTURE RESISTANT POLYMER WRAP.
2.WATERPROOFING OF THE STORMTRAP DETENTION SYSTEM VAULT WILL BE ACHIEVED BY WRAPPING BELOW
THE VAULT SLAB AND AROUND THE PERIMETER OF THE EXTERIOR WALLS, WITH AN IMPERMEABLE LINER. THE
LINER WILL BE A MINIMUM OF 40 MIL THICKNESS WITH 1300 PSI PUNCTURE STRENGTH AND IS NSF61 PLANT
AND FISH SAFE CERTIFICATION.
3.IF ANY WELDED LINER JOINTS ARE REQUIRED TO PERFORM THE INSTALLATION, THEY SHALL BE AIR TESTED AT
THE SEAM PRIOR TO ANY BACKFILL. SEAMS IN THE LINER SHOULD BE SOLVENT WELDED.
4.THE AIR-TEST WILL IDENTIFY IF ANY GAPS IN THE SEAM WELDS ARE PRESENT. ANY GAPS IN THE SEAM WELLS
NEED TO BE ADDRESSED AND RE-AIR TESTED.
5.ANY PIPES ENTERING OR LEAVING THE VAULT NEED TO HAVE PIPE PENETRATION "BOOTS" INSTALLED PER THE
LINER MANUFACTURER’S RECOMMENDATIONS, TO ENSURE WATERTIGHTNESS OF THE MODULAR VAULT
SYSTEM. BOOTS CAN EITHER BE PREFABRICATED BY THE LINER FABRICATOR OR FIELD FABRICATED BY THE
CONTRACTOR. A PIPE CLAMP SHOULD BE USED TO SEAL THE BOOT AROUND THE PIPE.
6.AFTER COMPLETION OF THE INSTALLATION OF IMPERMEABLE LINER AND THE MODULAR VAULT SYSTEM, THE
CONTRACTOR WILL ALSO PERFORM A WATER TIGHTNESS TEST BY PLUGGING THE VAULT OUTFALL PIPE AND
FILLING THE VAULT WITH WATER TO THE CONTROL STRUCTURE OVERFLOW ELEVATION. A FALLING HEAD TEST
WILL THEN BE IMPLEMENTED TO ENSURE THE SYSTEM HAS NO SIGNIFICANT MEASURABLE LEAKS. THE
WATER TIGHTNESS TEST SHALL BE OBSERVED AND APPROVED BY THE CITY OF RENTON SITE INSPECTOR
PRIOR TO APPROVAL OF FINAL BACKFILL TO FINISHED GRADE AND BRINGING THE DETENTION SYSTEM
ONLINE.
STORMTRAP SUPPLEMENTAL INSTALLATION NOTES
LANDSCAPE RESTORATION
GROUND SOURCE WELL
R-432616
TE
D
-
4
0
-
4
3
2
6
R-432616
DEVELOPMENT ENGINEERING
msippo 08/07/2025
DU
V
A
L
L
A
V
E
.
N
.
E
.
(A
D
E
D
I
C
A
T
E
D
P
U
B
L
I
C
R
I
G
H
T
O
F
W
A
Y
)
X X
X
X
XXX
X
X
X
IMPROVED BASEBALL FIELD
WITH SYNTHETIC SURFACE
AND UNDERDRAINS PER
LANDSCAPE PLANS
T
E E E E E E E
E
E
E
CO
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SU
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
SUB
SUB
S
U
B
S
U
B
S
U
B
S
U
B
SUB
S
U
B
S
U
B
S
U
B
SUB
S
U
B
S
U
B
S
U
B
SD
SD
SD
SD
SD
SD
SD
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
EEEE
E
E
E
E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EEEEEEEE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
SD
SD
SD
SD
SD
SD
E
E
E
EXISTING CITY OF
RENTON WATER
EASEMENT
15'
GROUND SOURCE VAULT PER MECH'L PLANS
CONTRACTOR SHALL PROVIDE SUMP PUMP
AND POWER INSIDE VAULT TO
PUMP STORMWATER THAT MAY ACCUMULATE
INSIDE VAULT UP TO 4" SD OUTLET
PIPE AT ELEV 457.80 (+ 7.8' +/-)
SEE SUMP PUMP NOTES ON SHEET C202
STORMTRAP MODULAR PRECAST DETENTION SYSTEM
10' INTERIOR VAULT HEIGHT
9' LIVE STORAGE DEPTH
PROVIDING 47,398 CF OF LIVE STORAGE VOLUME
52,664 CF OF TOTAL STORAGE VOLUME
SEE SHEETS C316 AND C317 AND DETAIL
NEW FIELD LIGHTING
AND CONDUITS PER
ELEC'L PLANS (TYP)
RESTORE EX LAWN AND
GRAVEL PATH AS REQ'D TO
INSTALL NEW GROUND
SOURCE PIPING AND VAULT
45
7
46
0
46
0
45
8
45
9
45
9
CONNECT TO FIELD
UNDERDRAIN PER
LANDSCAPE PLANS
IE= 453.34
12" VAULT VENTS
(TYP OF 6)
SEE DETAIL
VAULT ACCESS
RISER (TYP OF 2)
4'x4' GRATED VAULT ACCESS HATCH
(TYP OF 3) SIMILAR TO A UTILITY VAULT 444-LA
BUT WITH OPEN GRATING. INSTALL CONCRETE
RISERS AS NECESSARY TO MEET FINISHED
GRADE. GROUT BOTTOM RISER TO TOP OF
STORM TRAP LID. ALL RISER SECTIONS SHALL
BE GROUTED IN PLACE (TYP). INSTALL LADDER
BELOW EACH ACCESS HATCH. SEE DETAIL
11 LF 12"
PVC @ 2.3%
32 LF 12"
PVC @ 2.3%
SD B1 CB TYPE I
RIM 456.06
IE 453.34 8"(IN)E
IE 453.00 12"(OUT)N
SEE DETAIL (TYP)
C312
10
INSTALL TEMPORARY CATCH BASIN FILTER
SOCKS ON ALL NEW CATCH BASINS UNTIL
SITE IS STABILIZED. SEE DETAIL 7/C110.
C310
4
(2) 10" GROUND SOURCE
LINES PER MECH'L PLANS
FIELD SUB-DRAINAGE
COLLECTOR PIPE PER
L'SCAPE PLANS
FIELD SUB-DRAINAGE
PIPING PER L'SCAPE
PLANS (TYP)
GROUND SOURCE WELL
BELOW FIELD PER
MECH'L PLANS (TYP)
PROVIDE TEMPORARY SHORING (TRENCH BOX,
STEEL PLATES, ECOLOGY BLOCKS, OR OTHER
MEANS AND METHODS APPROACH) AS
REQUIRED TO PROTECT EXISTING BACKSTOP
FENCING/POLES AND FOUNDATIONS,
BATTING/PITCHING CAGE, AND DUGOUTS TO
REMAIN AND NOT BE DISTURBED DURING
INSTALLATION OF GROUND SOURCE WELLS
AND SYNTHETIC TURF FIELD.
4" VAULT DRAIN
IE 457.80
20 LF 4" SD (SCHED
80 PVC) @ 2.0%
CONNECT NEW 4"
STORM PIPE TO EX
CATCH BASIN
IE 457.40
STANDARD DUTY
ASPHALT RESTORATION
SEE DETAIL
C300
7
REPAINT EX PARKING LOT
STRIPING AS REQUIRED
REPLACE EX CHAINLINK
FENCE AND CONCRETE MOW
STRIP MATCHING EX IN KIND
APPROXIMATE ELECTRICAL
CONDUIT ROUTING TO CTE
ROOM PER ELEC'L PLANS
WATER X-ING
ASSUMED 6" DI WATER
PIPE 3-FT DEEP
RESTORE EX LAWN AND
GRAVEL PATH AS REQ'D
TO INSTALL NEW
GROUND SOURCE PIPING
7
'
9.2'
INSTALL ROUND ACCESS
COVERS IN LINE WITH LADDERS
WITHIN TYPE II CATCH BASINS
REPLACE EXISTING
FENCE AS NEEDED FOR
STORM INSTALLATION
DETENTION VAULT
INLET
IE 452.00
DETENTION VAULT
OUTLET
IE 444.00
SD A1 CB TYPE II - 54"
RIM 455.09
IE 444.00 12"(IN)NE
IE 444.00 12"(OUT)S
W/ CONTROL STRUCTURE
SEE DETAILS
C313
2
20 LF 12" PVC
@ 0.0% (FLAT)
12 LF 12" PVC @ 2.0%
SD A3 CB TYPE II - 48"
RIM 455.51
IE 440.39 12"(IN)N
IE 440.39 12"(OUT)SW
SEE DETAIL
C310
3
124 L
F
1
2
"
P
V
C
@
8
.
3
%
SD A4 CB TYPE II - 48"
RIM 434.84
IE 430.11 12"(IN)NE
IE 430.11 12"(OUT)W
16 LF 12"
PVC @ 10.0%
INERCEPT EX
12" STORM PSD
SD A5 CB TYPE I
RIM 431.56
IE 428.54 12"(IN)E
IE 428.54 12"(IN)S(EX)
IE 428.54 12"(OUT)N(EX)
POTHOLE PRIOR TO INSTALLATION
OF UPSTREAM CONVEYANCE
AND DETENTION
NOTE: ARBORIST SHALL BE ON-SITE
DURING TREE REMOVAL AND
STORM PIPING INSTALLATION
APPROXIMATE LIMITS OF
PROPOSED RESTORATION FOR
STORM PIPING EXCAVATION
PER LANDSCAPE PLANS
RESTORE EX CONCRETE
CURBS AND SIDEWALKS
AT NEAREST JOINT
SEE DETAILS
C300
3
C300
10
C310
3
C310
5
SEE SHEET C202 FOR "STORMTRAP
SUPPLEMENTAL INSTALLATION NOTES"
STORM PROFILE
C321
A
STORM PROFILE
C321
B
REPLACE CURB,
GUTTER, AND SIDEWALK
TO NEAREST JOINT
NOTE:
FOR ALL EXTERIOR CONCRETE PAVEMENT,
PROVIDE SPRAY-LOCK P3 OR EQUAL CONCRETE
PAVING SURFACE TREATMENT TO HELP PROTECT
CONCRETE AGAINST WINTER DE-ICING SALT PER
PROJET SPECIFICATION SECTION 321313.23
C310
8
457.64 (EX)
457.40 (EX)
457.54 (EX)456.89 (EX)
456.66 (EX)
456.31 (EX)
456.51 (EX)
456.55 (EX)
457.49 (EX)
457.42 (EX)
EXISTING 10" WATER MAIN TO BE PROTECTED AT ALL TIMES.
PROTECTION SHALL INCLUDE, BUT NOT LIMITED TO,
PROHIBITION OF HEAVY MACHINERY AND DRILLING EQUIPMENT
ON TOP OF MAIN OR WITHIN EASEMENT. VIBRATIONAL TESTING
MAY BE REQUIRED FOR ANY DRILLING OR PILING OCCURRING
NEAR THE MAIN. ADDITIONALLY, ANY MACHINERY CROSSING
THE WATER MAIN IN UNPAVED AREAS WILL BE REQUIRED TO
UTILIZE SHEETING OR SIMILAR MECHANISM TO ENSURE THAT
THE MAIN IS NOT SUBJECT TO DAMAGE LOADS.
456.98 (EX)
456.86 (EX)
455.39 (EX)
455.88 (EX)
2
0
.
3
'
20'
6.
7
'
15.5
'
12
5
L
F
1
2
"
P
V
C
@
1
.
5
%
SD A2 MODULAR WETLAND
MWS-L-4-6-V-UG
RIM 455.54
IE 443.76 12"(IN)N
IE 442.26 12"(OUT)S
SEE DETAIL
C318
1
EXISTING 10" PRIVATE CLAY SEWER MAIN TO BE PROTECTED AT ALL
TIMES. PROTECTION SHALL INCLUDE, BUT NOT LIMITED TO,
PROHIBITION OF HEAVY MACHINERY AND DRILLING EQUIPMENT ON
TOP OF MAIN, VIBRATIONAL TESTING MAY BE REQUIRED FOR ANY
DRILLING OR PILING OCCURRING NEAR THE MAIN. ADDITIONALLY,
ANY MACHINERY CROSSING THE WATER MAIN IN UNPAVED AREAS
WILL BE REQUIRED TO UTILIZE SHEETING OR SIMILAR MECHANISM
TO ENSURE THAT DAMAGE DOES NOT OCCUR TO THE MAIN.
SD B2 CB TYPE II - 48"
CONTECH CDS2015-4-C
RIM 456.03
IE 452.25 12"(IN)S
IE 452.25 12"(OUT)NE
SEE DETAIL
C318
4
457.95(EX)
458.24(EX)
459.12(EX)
459.42(EX)
459.71(EX)
461.04(EX)
456.48(EX)
456.55(EX)
458.00(EX)
460.68(EX)
460.83(EX)
460.80(EX)
460.58(EX)
460.46(EX)
459.94(EX)
458.39(EX)
INSTALL ANTI-SEEP
COLLAR ON 12" STORM
PIPE AT PROPERTY LINE
SEE DETAIL
C312
1
10" DI WATERMAIN
(PER CONTRACTOR
POTHOLE)
C317
1
10" DI WATERMAIN
(PER SURVEY)
MAINTAIN 18" VERTICAL
SEPARATION BETWEEN WATER AND
ELECTRICAL LINE. ELECTRICAL LINE
SHALL ROUTE UNDERNEATH THE
EXISTING 8" WATER MAIN (TYP)
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
PROPERTY LINE
CONTOUR (INDEX)
CONTOUR
GRADE BREAK
SPOT ELEVATION
110
109.36
109
TC 109.86
BC 109.36
ASPHALT PAVEMENT
CONCRETE CURB
CONCRETE PAVEMENT
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
CIVIL SITE PLAN
MATCHLINE - SEE SHEET C202
MATCHLINE - SEE SHEET C204
FOR TYPICAL TRENCH AND BACKFILL,
FOR STORM PIPING, SEE DETAIL 6/C310.
STORM DRAINAGE PIPE
MH / EX CB 2 / CB 2 / CB/ YD / CO
SD
PROPOSED DETENTION SYSTEM
LANDSCAPE RESTORATION
GROUND SOURCE WELL
SYNTHETIC FIELD
R-432617
TE
D
-
4
0
-
4
3
2
6
R-432617
as a condition of approval a stormwater adjustment for
vault grated surface area and maintenance access shall
be submitted and approved prior to civil permit closeout
revisions warranted by adjustment shall be submitted
for review and approval as a minor change
DEVELOPMENT ENGINEERING
msippo 08/07/2025
XXXX
X
X
X
X
X
XX
X
X
X
X X X X
X
X
X
X
XXXXX
X
X
X
X
X
X
X
X
X
IMPROVED BASEBALL FIELD
WITH SYNTHETIC SURFACE
AND UNDERDRAINS PER
LANDSCAPE PLANS
15
'
EXISTING CITY OF
RENTON WATER
EASEMENT
15'
EXISTING CITY OF
RENTON WATER
EASEMENT
PROTECT EX 8"
PRIVATE SEWER MAIN
PROTECT EX 12"
PRIVATE STORM MAIN
CITY OF RENTON
WATER MAIN
T
E
E
E
E
E
E
E E E E E E E E E E E E E E
E
E
E
E
E
E
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
S
U
B
EEEEEE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EEEEEE
E
E
E
E
E
E
E
E
E
E
E
EEEEEEE
E
E
E
E
E
E
E
E
E
E E E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
DOUBLE GATE
BY OTHERS
FENCED
ENCLOSURE
BY OTHERS
ELECTRICAL
EQUIPMENT
(EXTENTS TBD)
ELECTRICAL TRANSFORMER,
SEE ELEC. PLANS
PAD ELEVATION AT 464.0
NEW ELECTRICAL
PRIMARY SERVICE
EXISTING DOUBLE DOORS TO
MECHANICAL ROOM RAISE
THRESHOLD GRADE AT
DOOR TO BE -0.02' BELOW
FFE OR ELEV 463.43
1
C320
C320
2
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
PROTECT EX STORM
STRUCTURE TO
REMAIN
6" CONCRETE PAD
SEE DETAIL
C300
4
6" CONCRETE PAD FOR ELECTRICAL
SWITCHGEAR PER ELEC. PLANS
PAD ELEVATION AT 463.65 (MATCH EX
FFE) AT BUILDING, SLOPE PAD AT
1.5% MIN FOR POSITIVE DRAINAGE
AWAY FROM BUILDING. SEE DETAIL C300
4
(2) 10" GROUND SOURCE
LINES PER MECH'L PLANS
(2) 10" GROUND SOURCE
LINES PER MECH'L PLANS
ASPHALT
THICKENED EDGE
SEE DETAIL
C300
5
UTIL X-ING
EX 8" SS TOP 460.42 (ASSUMED)
4" ELEC CONDUIT IE 460.67
INSTALL ETHAFOAM PAD FOR VERTICAL PIPE
CLEARANCE OF LESS THAN 12-INCHES
SEE DETAIL
C300
1
UTIL X-ING
EX 12" SD TOP 453.83
4" ELEC CONDUIT IE 456.72
UTIL X-ING
EX 12" SD TOP 454.56
10" GROUND
SOURCE PIPE IE 455.37
UTIL X-ING
EX 8" SS IE 456.56
10" GROUND SOURCE
PIPE TOP 456.19
CONTRACTOR SHALL POTHOLE AND
VERIFY DEPTH, LOCATION, AND
MATERIAL OF EX 8" SEWER PIPE
PRIOR TO CONSTRUCTION
46
0
SINGLE GATE
BY OTHERS
UTIL X-ING
EX 10" COR WATER (PER
CONTRACTOR) IE 457.98
10" GROUND SOURCE TOP 456.71
UTIL X-ING
EX IRRIGATION IE 459.56
(UNKNOWN SIZE & ASSUMED
DEPTH)
10" GROUND SOURCE PIPE
TOP 457.40
CONTRACTOR SHALL RELOCATE
EX IRRIGATION AS NEEDED TO
CLEAR GROUND SOURCE PIPING
CONTRACTOR SHALL RELOCATE
EX IRRIGATION AS NEEDED TO
CLEAR NEW POWER CONDUITS
CAST-IN-PLACE CONCRETE
RETAINING WALL
INCLUDING TOP OF WALL
ELEVATIONS PER
STRUCTURAL PLANS
12'
70.7' FIELD VERIFIED
10" DI WATERMAIN
(PER SURVEY)
10" DI WATERMAIN
(PER CONTRACTOR POTHOLE)
EXISTING 10" WATER MAIN TO BE PROTECTED AT ALL TIMES.
PROTECTION SHALL INCLUDE, BUT NOT LIMITED TO,
PROHIBITION OF HEAVY MACHINERY AND DRILLING EQUIPMENT
ON TOP OF MAIN OR WITHIN EASEMENT. VIBRATIONAL TESTING
MAY BE REQUIRED FOR ANY DRILLING OR PILING OCCURRING
NEAR THE MAIN. ADDITIONALLY, ANY MACHINERY CROSSING
THE WATER MAIN IN UNPAVED AREAS WILL BE REQUIRED TO
UTILIZE SHEETING OR SIMILAR MECHANISM TO ENSURE THAT
THE MAIN IS NOT SUBJECT TO DAMAGE LOADS.
CAUTION - PROTECT AND
SUPPORT EX WATER
MAIN AS NEEDED
MAINTAIN 18" VERTICAL
SEPARATION BETWEEN WATER AND
ELECTRICAL LINE. ELECTRICAL LINE
SHALL ROUTE UNDERNEATH THE
EXISTING 10" WATER MAIN (TYP)
ASPHALT THICKENED
EDGE WHERE NEW
ASPHALT MEETS
LANDSCAPING (TYP)
SEE DETAIL
C300
5
ASPHALT THICKENED
EDGE WHERE NEW
ASPHALT MEETS
LANDSCAPING
460.80(EX)
460.58(EX)
460.46(EX)
459.94(EX)
REPLACE FENCE AND MOW
STRIP IN KIND AS NEEDED
TO INSTALL GROUND
SOURCE WELL PIPING
FENCED ENCLOSURE
BY OTHERS
ALL UTILITY TRENCHES TO
MATCH EXISTING GRADE
MAINTAIN 18" VERTICAL
SEPARATION BETWEEN WATER AND
ELECTRICAL LINE. ELECTRICAL LINE
SHALL ROUTE UNDERNEATH THE
EXISTING 8" WATER MAIN (TYP)
UTIL X-ING
EX 10" COR WATER (RECORD)
IE 457.98
10" GROUND SOURCE TOP 456.71
20'
8'
5'4" CONCRETE
SIDEWALK LANDING
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
PROPERTY LINE
CONTOUR (INDEX)
CONTOUR
GRADE BREAK
SPOT ELEVATION
110
109.36
109
TC 109.86
BC 109.36
ASPHALT PAVEMENT
CONCRETE CURB
CONCRETE PAVEMENT
SCALE 1"=10'
5 10 200
HAZEN HIGH SCHOOL MODERNIZATION
CIVIL SITE PLAN
MATCHLINE - SEE SHEET C203
NOTE:
FOR ALL EXTERIOR CONCRETE PAVEMENT,
PROVIDE SPRAY-LOCK P3 OR EQUAL CONCRETE
PAVING SURFACE TREATMENT TO HELP PROTECT
CONCRETE AGAINST WINTER DE-ICING SALT PER
PROJECT SPECIFICATION SECTION 321313.23
LANDSCAPE RESTORATION
GROUND SOURCE WELL
SYNTHETIC FIELD
R-432618
TE
D
-
4
0
-
4
3
2
6
R-432618
DEVELOPMENT ENGINEERING
msippo 08/07/2025
N.E. 10TH ST.
( A DEDICATED PUBLIC RIGHT OF WAY)
E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
S
U
B
SUB
SUB
S
U
B
SUB
SUB
SUB
SUB
SUB
SU
B
SUB SUB SUB SUB
SUB SUB SUB SUB
SU
B
SU
B
SU
B
SU
B
SUB SUB SUB
SU
B
SU
B
SU
B
SU
B
SUB SUB SUB
SU
B
SU
B
SU
B
SUB SUB
SU
B
SU
B
SU
B
SUB SUB
SU
B
SU
B
SUB
SU
B
SU
B
SUB
SU
B
SU
B
SU
B
SUB
SU
B
SU
B
SUB SUB
SU
B
SU
B
SUB SUB
SU
B
SU
B
SU
B
SUB SUB SUB
SU
B
SU
B
SU
B
SUB SUB SUB
SU
B
SU
B
SU
B
SU
B
SUB SUB SUB SUB
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SUB SUB SUB SUB
SU
B
SU
B
SU
B
SUB SUB SUB
SU
B
SU
B
SUB SUB
SU
B
SUB
SU
B
SU
B
SUB
SU
B
SU
B
SUB
SU
B
SU
B
SUB SUB
SU
B
SU
B
SU
B
SUB SUB
SU
B
SU
B
SU
B
SU
B
SUB SUB SUB
SU
B
SU
B
SU
B
SU
B
SUB SUB SUB
SU
B
SU
B
SU
B
SU
B
SUB SUB SUB SUB
SU
B
SU
B
SU
B
SU
B
SU
B
SD
E
E
E
E
E
E
E
E
E
SD
SD
E
E
E
EEE
E
EEEEEEEEEE
EEEEEE
EEEE
E E E E
E EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E E E E E
IMPROVED SOFTBALL FIELD
WITH SYNTHETIC SURFACE
AND UNDERDRAINS PER
LANDSCAPE PLANS
NEW ELECTRICAL
PRIMARY SERVICE PER
ELECTRICAL PLANS
ADS MC-3500 STORMTECH CHAMBER
DETENTION SYSTEM
REQUIRED LIVE STORAGE = 22,265 CF
TOTAL STORAGE VOLUME = 27,943 CF
152 CHAMBERS AND 8 END CAPS IN 4 ROWS
9" GRAVEL BASE, 12" GRAVEL PERIMETER,
AND 12" GRAVEL COVER
SEE SHEET C314 AND SEE DETAIL
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
NEW FIELD LIGHTING
PER ELEC'L PLANS (TYP)
RESTORE EX LAWN, GRAVEL
PATH, AND ASPHALT AS
REQ'D TO INSTALL NEW
ELECTRICAL SERVICE
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
10 LF 12"
PVC @ 5.0%
SD C1 CB TYPE II - 54"
W/ ROUND SOLID
LOCKING COVER
RIM 476.84
IE 470.36 12"(IN)NE
IE 470.36 12"(OUT)W
W/ CONTROL STRUCTURE
SEE DETAILS
SD C3 CB TYPE I
RIM 471.37
IE 466.53 12"(IN)E (AT DROP)
IE 466.53 12"(OUT)S
12" DETENTION
OUTLET
IE 470.36
INSTALL TEMPORARY CATCH BASIN FILTER
SOCKS ON ALL NEW CATCH BASINS UNTIL
SITE IS STABILIZED. SEE DETAIL 7/C110.
INSTALL ROUND ACCESS
COVERS IN LINE WITH LADDERS
WITHIN TYPE II CATCH BASINS
C313
3
C310
3
C310
5
4
6
9465466463464
470
471
STORM PROFILE
C322
C
C312
6
FOR CONTINUATION OF
ELECTRICAL CONDUIT
ROUTING, SEE SHEET C204
ASPHALT THICKENED
EDGE WHERE NEW
ASPHALT MEETS
LANDSCAPING (TYP)
SEE DETAIL
C300
5
32 LF 12"
PVC @ 5.8%
SD C2 MODULAR WETLAND
MWS-L-4-6-V-UG
RIM 476.56
IE 469.87 12"(IN)E
IE 468.37 12"(OUT)W
SEE DETAIL
C318
2
SD C4 CB TYPE I
RIM 468.55
IE 465.62 12"(IN)N
IE 465.62 12"(OUT)SW
31 LF 12"
PVC @ 2.9%
14 LF 12"
PVC @ 2.9%
CONNECT TO EX SDMH
IE 465.20 12"(IN)NW EX WATER
DISTRICT 90
WATER MAIN
INSPECTION
PORT (TYP OF 8)
INSPECTION PORT LIDS TO BE
SET 6" BELOW TURF SURFACING
WITH REMOVABLE ACCESS
PANEL PER LANDSCAPE PLANS
SUBDRAINAGE PIPING TO
DISCHARGE DIRECTLY TO ROCK
SURROUNDING CHAMBER SYSTEM
SEE DETAIL
C312
11
30 LF 12"
PVC @ 0.0%
47
7
477
477
FENCE PER
LANDSECAPE PLANS
476.97(EX)
477.00(EX)
477.00(EX)
476.96(EX)
476.98
476.96
476.94
477.01(EX)476.99(EX)
476.93(EX)
INSTALL ANTI-SEEP
COLLAR ON 12" STORM
PIPE AT PROPERTY LINE
SEE DETAIL
C312
1
PROPOSED STREET
LIGHTING AND CONDUIT
ROUTING PER
ELECTRICAL PLANS (TYP)
46
546
4
46
6
46
7
468
469
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
PROPERTY LINE
CONTOUR (INDEX)
CONTOUR
GRADE BREAK
SPOT ELEVATION
110
109.36
109
TC 109.86
BC 109.36
ASPHALT PAVEMENT
CONCRETE CURB
CONCRETE PAVEMENT
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
CIVIL SITE PLAN
MATCHLINE - SEE SHEET C207
STORM DRAINAGE PIPE SD
PROPOSED DETENTION SYSTEM
FOR TYPICAL TRENCH AND BACKFILL,
FOR STORM PIPING, SEE DETAIL 6/C310.
FOR WORK IN THE
RIGHT-OF-WAY
SEE SHEET C209
MH / EX CB 2 / CB 2
/ CB/ YD / CO
NOTE:
FOR ALL EXTERIOR CONCRETE
PAVEMENT, PROVIDE SPRAY-LOCK P3
OR EQUAL CONCRETE PAVING SURFACE
TREATMENT TO HELP PROTECT
CONCRETE AGAINST WINTER DE-ICING
SALT PER PROJET SPECIFICATION
SECTION 321313.23
LANDSCAPE RESTORATION
SYNTHETIC FIELD
R-432619
TE
D
-
4
0
-
4
3
2
6
R-432619
DEVELOPMENT ENGINEERING
msippo 08/07/2025
Surface Water Enginering
jfarah 08/11/2025
SSSSSSSSSSSSSSSS
6" CONCRETE PAD
FOR FUTURE
GREENHOUSE
SEE DETAIL
C300
4
PLUMBING POC FOR NEW ACID
WASTE LINE. SEE MECH'L PLANS
FOR NEW ACID WASTE PIPING
IE UNKNOWN
CONTRACTOR SHALL POTHOLE AND
VERIFY LOCATION, DEPTH, AND
MATERIAL PRIOR TO STARTING
CONSTRUCTION
NEW 6" PP ACID WASTE STUB TO
BUILDING. IE 464.14
SEE MECH'L PLANS FOR NEW
ACID WASTE PIPING
NEW 6" PP ACID WASTE STUB TO
BUILDING. IE 464.14
SEE MECH'L PLANS FOR NEW
ACID WASTE PIPING
86 LF 6" PP ACID WASTE LINE @ 2.0%
6" SSCO
RIM TO GRADE
IE 464.09
SEE DETAIL
REPLACE CONCRETE
SIDEWALK
SEE DETAIL
C300
3
REPLACE CONCRETE
SIDEWALK
SEE DETAIL
C300
3
2.5'
6" 45° BEND
IE 462.37 6" WYE
IE 462.62
C311
1
15'
40
'
LOCATION OF ECO PAN FOR
CONCRETE PUMPER TRUCK
WASHOUT LOCATED EAST IN
PARKING LOT. SEE SHEET C010.
CONTRACTOR SHALL MAKE A
RECORD OF EXISTING
SCORE/JOINT LINES FOR COURTYARD
TO BE MATCHED FOR FINISHED
CONCRETE CONDITION. (TYP)
RESTORE EX CONCRETE
PAVEMENT WITH STANDARD
CONCRETE SIDEWALK
SECTION SEE DETAIL
C300
3
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
PROPERTY LINE
CONTOUR (INDEX)
CONTOUR
GRADE BREAK
SPOT ELEVATION
110
109.36
109
TC 109.86
BC 109.36
ASPHALT PAVEMENT
CONCRETE CURB
CONCRETE PAVEMENT
SCALE 1"=10'
5 10 200
HAZEN HIGH SCHOOL MODERNIZATION
CIVIL SITE PLAN
FOR TYPICAL TRENCH AND BACKFILL,
FOR SEWER PIPING, SEE DETAIL 6/C310.
SANITARY SEWER
SANITARY MH/CO
SS
NOTE:
FOR ALL EXTERIOR CONCRETE
PAVEMENT, PROVIDE SPRAY-LOCK P3
OR EQUAL CONCRETE PAVING SURFACE
TREATMENT TO HELP PROTECT
CONCRETE AGAINST WINTER DE-ICING
SALT PER PROJET SPECIFICATION
SECTION 321313.23
R-432620
TE
D
-
4
0
-
4
3
2
6
R-432620
DEVELOPMENT ENGINEERING
msippo 08/07/2025
□
□
□
SUB
S
U
B
SUB
SUB SUB
SU
B
SU
B
SU
B
SU
B
SUB SUB
SU
B
SU
B
SU
B
SU
B
SUB
SU
B
SU
B
SU
B
SUB
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SUB
SUB
SUB SUB
SUB SUB
SUB SUB SUB
SUB SUB SUB
SU
B
SU
B
SU
B
SU
B
SU
B
W
E
E E E E
E
E
E
E E E E
E
E
E
E
EEE
E
EEEEEEEEEE
EEEEEE
E
E
IMPROVED SOFTBALL FIELD
WITH SYNTHETIC SURFACE
AND UNDERDRAINS PER
LANDSCAPE PLANS
ADS MC-3500 STORMTECH CHAMBER
DETENTION SYSTEM
REQUIRED LIVE STORAGE = 22,265 CF
TOTAL STORAGE VOLUME = 27,943 CF
152 CHAMBERS AND 8 END CAPS IN 4 ROWS
9" GRAVEL BASE, 12" GRAVEL PERIMETER,
AND 12" GRAVEL COVER
SEE SHEET C314 AND SEE DETAIL
RESTORE CONCRETE
SIDEWALK
SEE DETAIL (TYP)
C300
3
NEW NON-REMOVEABLE
HEAVY DUTY VEHICULAR
RATED SECURITY BOLLARD
(TYP UNLESS OTHERWISE
NOTED) SEE DETAIL
C301
6
PROPOSED
TEMPORARY
PORTABLE
FFE 471.74PROPOSED
TEMPORARY
PORTABLE
FFE 471.90
470.62 (EX)
470.29 (EX)
470.38 (EX)
470.94 (EX)
470.34 (EX)
470.67 (EX)
470.67 (EX)
PROPOSED TEMPORARY MODULAR
BUILDINGS PER ARCH'L PLANS TO BE
REMOVED AT COMPLETION OF
CONSTRUCTION UNDER SEPARATE PERMIT
25'
6'
EX ACCESSIBLE
ROUTE
EX TABLE TOP
CROSSING
PROTECT EX CATCH BASIN TO REMAIN;
LEAVE GAP IN TEMPORARY PORTABLE
FOUNDATION SKIRTING FOR DRAINAGE
TO THIS CB TO BE MAINTAINED
5.9'
4'
INSTALL NEW REMOVABLE
HEAVY DUTY VEHICULAR RATED
SECURITY BOLLARD (1 TOTAL)
SECURITY BOLLARDS SHALL NOT BE
PLACED OVER EXISTING 10" COR
WATERMAIN. BOLLARDS WITH
FOUNDATION SHALL BE A MINIMUM OF 5'
FROM THE EXISTING 10" WATER MAIN
SEE DETAIL
C301
10
REPLACE EX CONCRETE
CURB/GUTTER,
SIDEWALK, AND
ASPHALT PAVING
HO
Q
U
I
U
M
A
V
E
.
N
.
E
.
(A
D
E
D
I
C
A
T
E
D
P
U
B
L
I
C
R
I
G
H
T
O
F
W
A
Y
)
5'
PAINTED "WHITE"
PEDESTRIAN
PATHWAY STRIPING
SEE DETAIL
8'
PAINTED "WHITE"
CROSSWALK STRIPING
SEE DETAIL
C300
9
INSTALL TEMPORARY CATCH BASIN FILTER
SOCKS ON ALL NEW CATCH BASINS UNTIL
SITE IS STABILIZED. SEE DETAIL 7/C110.
EX ACCESSIBLE
RAMP
INSTALL ROUND ACCESS
COVERS IN LINE WITH LADDERS
WITHIN TYPE II CATCH BASINS
470.54 (EX)
C312
6
150-FT FIRE
HYDRANT HOSE
PULL DISTANCE
EXISTING 10" WATER MAIN TO BE PROTECTED AT ALL TIMES.
PROTECTION SHALL INCLUDE, BUT NOT LIMITED TO,
PROHIBITION OF HEAVY MACHINERY AND DRILLING EQUIPMENT
ON TOP OF MAIN OR WITHIN EASEMENT. VIBRATIONAL TESTING
MAY BE REQUIRED FOR ANY DRILLING OR PILING OCCURRING
NEAR THE MAIN. ADDITIONALLY, ANY MACHINERY CROSSING
THE WATER MAIN IN UNPAVED AREAS WILL BE REQUIRED TO
UTILIZE SHEETING OR SIMILAR MECHANISM TO ENSURE THAT
THE MAIN IS NOT SUBJECT TO DAMAGE LOADS.
EX GENERATOR TO
BE RELOCATED
PER ELEC'L PLANS
EX TRANSFORMER TO
BE RELOCATED
PER ELEC'L PLANS
RELOCATED EX
GENERATOR PER
ELEC'L PLANS
NEW EXTRUDED
CONCRETE CURB
SEE DETAIL (TYP)
C300
11
8'
3'
PROTECT EX
SECURITY
CAMERA
NEW 6' HIGH
CHAINLINK FENCE
WITH PRIVACY SLATS
PER L'SCAPE PLANS
NEW 6' HIGH BY 12' WIDE
CHAINLINK GATE (2 - 6' LEAFS)
WITH PRIVACY SLATS
PER L'SCAPE PLANS
7.9'
BOLLARD DEPTH IS 30"
DEEP BY 16" WIDE.
CONTRACTOR SHALL USE
CAUTION WHEN PERFORMING
CONSTRUCTION NEAR OR OVER
EXISTING CHARGED WATERMAIN.
SEE DETAIL
C301
6
32 LF 6" DI CL52
WET-TAP FOR NEW FIRE HYDRANT ASSEMBLY
INSTALL 10"X6" TEE(MJXFL)
INSTALL 6" GATE VALVE (FLXMJ)
W/ CONCRETE THRUST BLOCKING
WET-TAPPING OF EXISTING 10-INCH WATERMAIN
SHALL BE PERFORMED BY THE FOLLOWING
LICENSED WET TAP CONTRACTORS
1. LEGACY TAPPING, INC.
2. SPEER TAPS, INC.
SEE DETAILS
C319
1
C319
4
REPLACE EX ASPHALT
PAVEMENT WITH HEAVY
DUTY ASPHALT PAVEMENT
SEE DETAIL
C300
7
REPLACE EX CONCRETE
VERTICAL CURB AS REQUIRED
TO INSTALL NEW FIRE
HYDRANT ASSEMBLY
NEW 15-FT WATER EASEMENT
KC REC NO.___________
15'
7.
5
'
REPLACE EX SHRUBS AND
LANDSCAPING IN
PLANTER AS NEEDED
PROTECT EX
LIGHT POLE TO
REMAIN
FIRE HYDRANT ASSEMBLY
PROVIDE A 4'x4' CONCRETE
PAD FOR NEW FIRE HYDRANT
SEE DETAIL
C319
2
C319
7
2'
FIELD ADJUST EX IRRIGATION
CONTROL BOX AND OTHER
COMPONENTS IN THIS AREA TO
AVOID CONFLICT WITH RELOCATED
GENERATOR AND NEW FENCING
470.78
470.69(EX)470.57 (EX)
470.71 (EX)
470.56 (EX)
470.76 (EX)
470.66 (EX)
1.
8
%
3.
3
%
1.
8
%
1.
8
%
0.3%0.3%
470.85 (EX)
470.86 (EX)
470.80 (EX)470.87 (EX)
1.
0
%
0.
1
%
471.67 (EX)
471.65 (EX)
471.18 (EX)471.17 (EX)
0.2%
0.4%
C300
9
SALVAGE AND REMOVE EX
LIGHT POLE AND BASE TO
BE REINSTALLED AT
COMPLETION OF PROJECT
REMOVE EX CONCRETE WALK,
CURB, AND ASPHALT AS REQUIRED
TO INSTALL ELECTRICAL CONDUITS
AND VAULTS FOR TEMPORARY
PORTABLE POWER
BELOW TEMPORARY PORTABLE FOUNDATIONS
LOCATED WITHIN EXISTING LANDSCAPE PLANTER,
CONTRACTOR SHALL REMOVE EX PLANTING
MATERIAL AND SOIL DOWN TO SUBGRADE AND
COMPACT TO 95% AS REQUIRED. SUBGRADE THAT
DOES NOT MEET COMPACTION, SHALL BE REMOVED
A MIN. OF 12" AND REPLACED WITH IMPORT FILL
MATERIAL, THEN RECOMPACTED TO MEET 95%.
INSPECTION
PORT (TYP OF 8)
ECO PAN FOR CONCRETE
TRUCK CLEANOUT; FINAL
LOCATION TO BE
COORDINATED IN FIELD
DURING CONSTRUCTION.
INSPECTION PORT LIDS TO BE
SET 6" BELOW TURF SURFACING
WITH REMOVABLE ACCESS
PANEL PER LANDSCAPE PLANS
47
7
476.94
477.01(EX)476.99(EX)
476.93(EX)
4'
CONTRACTOR SHALL MAKE
A RECORD OF EXISTING
SCORE/JOINT LINES FOR
COURTYARD TO BE
MATCHED FOR FINISHED
CONCRETE CONDITION. (TYP)
RESTORE EX CONCRETE PAVEMENT
WITH STANDARD CONCRETE
SIDEWALK SECTION SEE DETAIL
C300
3 INSTALL 4-INCHES THICK
CSTC GRAVEL SURFACING
(5/8" MINUS). EXTEND
GRAVEL TO BACK OF CURB
5'
12.3'
8.
2
'
8.
1
'
7.
7
'
5'
7'
EX 10" WATERMAIN
470.65
470.95 (EX)
470.77 (EX)
470.73 (EX)
470.64 (EX)
470.52
470.66 1.
8
%
470.43 (EX)
470.67
1.
8
%
470.58 (EX)
470.75(EX)
470.84(EX)
1.
8
%
1.
8
%
8.
7
'
470.79 (EX)
1.
8
%
470.76 (EX)470.77 (EX)
2'
1.5'
1.
5
%
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
PROPERTY LINE
CONTOUR (INDEX)
CONTOUR
GRADE BREAK
SPOT ELEVATION
110
109.36
109
TC 109.86
BC 109.36
ASPHALT PAVEMENT
CONCRETE CURB
CONCRETE PAVEMENT
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
CIVIL SITE PLAN
NOTE:SEE ELECTRICAL PLANS FOR
POWER AND COMM FEEDS TO PORTABLE
NOTE:CONTRACTOR SHALL UTILIZE
PUBLIC AND PRIVATE UTILITY LOCATES
TO VERIFY EX UTILITIES
NOTE:PROPOSED PORTABLES ARE
"DRY" AND WILL NOT HAVE NEW
WATER OR SEWER SERVICES PROVIDED
COORDINATE WITH SCHOOL DISTRICT
FOR ACCESS TO AND FROM PROJECT SITE
MATCHLINE - SEE SHEET C205
STORM DRAINAGE PIPE SD
PROPOSED DETENTION SYSTEM
FOR TYPICAL TRENCH AND
BACKFILL, FOR STORM PIPING,
SEE DETAIL 6/C310.
FOR WORK IN THE
RIGHT-OF-WAY
SEE SHEET C208
MH / EX CB 2 / CB 2 / CB/ YD / CO
NOTE:
FOR ALL EXTERIOR CONCRETE
PAVEMENT, PROVIDE SPRAY-LOCK P3
OR EQUAL CONCRETE PAVING SURFACE
TREATMENT TO HELP PROTECT
CONCRETE AGAINST WINTER DE-ICING
SALT PER PROJET SPECIFICATION
SECTION 321313.23
HEAVY DUTY ASPHALT PAVEMENT
W-432601
WT
R
-
2
7
-
4
3
2
6
W-432601
DEVELOPMENT ENGINEERING
msippo 08/07/2025
WATER UTILITY
ABDOUL GAFOUR 08/08/2025
R-432621
W-432601
TE
D
-
4
0
-
4
3
2
6
REPLACE EX CONCRETE
CURB/GUTTER,
SIDEWALK, AND
ASPHALT PAVING
HOQUIUM AVE. N.E.
(A DEDICATED PUBLIC RIGHT OF WAY)FOR DETAILED HOQUIAM
AVE NE DRIVEWAY #1
IMPROVEMENTS
SEE DETAIL
C330
2
FOR DETAILED HOQUIAM
AVE NE DRIVEWAY #2
IMPROVEMENTS
SEE DETAIL
C330
3
DRIVEWAY TYPE C3 PER
COR STANDARD PLAN 104
SEE DETAIL
C303
6
HOQUIAM AVE. N.E.
N.
E
.
11
T
H
S
T
N.
E
.
10
T
H
P
L
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7 HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
DRIVEWAY TYPE C3 PER
COR STANDARD PLAN 104
SEE DETAIL C303
6
471
22+00 23+00 24+00 25+00 26+00 27+00
22+50 23+50 24+50 25+50 26+50
E
E
E
DRIVEWAY TYPE C3 PER
COR STANDARD PLAN 104
SEE DETAIL
FOR DETAILED HOQUIAM
AVE NE DRIVEWAY #3
IMPROVEMENTS
SEE DETAIL
C331
1
1.
5
%
C303
6 HOQUIAM AVE. N.E.
N.
E
.
12
T
H
S
T
N.
E
.
11
T
H
P
L
N.
E
.
11
T
H
C
T
EX RECENTLY
INSTALLED CURB CUT
RAMPS TO REMAIN
DRIVEWAY TYPE C3 PER
COR STANDARD PLAN 104
SEE DETAIL
C303
6
47
0
458
459
45
7
45
8
45
9
457
1
1
5'
6.7'
FOR DETAILED HOQUIAM
AVE NE DRIVEWAY #4
IMPROVEMENTS
SEE DETAIL
C331
2
28+00 29+00 30+00 31+00 32+00 33+00 33+18
27+50 28+50 29+50 30+50 31+50 32+50
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
PROPERTY LINE
CONTOUR (INDEX)
CONTOUR
GRADE BREAK
SPOT ELEVATION
110
109.36
109
TC 109.86
BC 109.36
ASPHALT PAVEMENT
CONCRETE CURB
CONCRETE PAVEMENT
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
HOQUIAM AVE NE CIVIL SITE PLAN
BUILDING VESTIBULE
MA
T
C
H
L
I
N
E
-
S
E
E
A
B
O
V
E
R
I
G
H
T
MA
T
C
H
L
I
N
E
-
S
E
E
B
E
L
O
W
L
E
F
T
PROTECT EX UTILITY
POLE AND GUY WIRE
KEYNOTES
1.CONCRETE CURB AND GUTTER AND ASPHALT
PAVING (ARTERIAL STREET SECTION) SEE DETAIL
FOR DETAILED RAMP
IMPROVEMENTS
SEE DETAIL
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
C303
8
T-432601
ADA CURB RAMP TYPE
PARALLEL A PER WSDOT
STANDARD PLAN
F-40.12-03
SEE DETAIL
C301
8
TR
O
-
4
1
-
4
3
2
6
C330
4
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
FOR DETAILED HOQUIAM
AVE NE DRIVEWAY #4
IMPROVEMENTS
SEE DETAIL
C331
2
T-432601
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432622
TE
D
-
4
0
-
4
3
2
6
E
E
E E E E E E
E
E
SUB
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SU
B
SD
SD
SD
EE
E
EE
E
E E E E E E E E E E E E E
SDSDSDSDSDSDSDSDSD
N.E. 10TH ST.
FI
E
L
D
AV
E
N
.
E
.
PROTECT EXISTING
TREE TO REMAIN
EXISTING GUARDRAIL TO BE
REPLACED WITH SHORTER 14' +/-
SECTION TYPE 13 GUARDRAIL PER
WSDOT STD PLAN C20.10-09
SEE DETAIL
ASPHALT PAVING
(RESIDENTIAL STREET SECTION)
SEE DETAIL (TYP)
5'
8.
5
'
EXISTING
2" GAS MAIN
EXISTING
POWER POLE
MATCH EXISTING
GRADE AT
PROPERTY LINE
CONCRETE CURB
AND GUTTER
SEE DETAIL (TYP)
C303
9
CONCRETE
SIDEWALK SEE
DETAIL (TYP)
C303
7
18'6'
8'
470
471
4
6
9
457
4
5
5
POWER POC FOR NEW PEDESTRIAN SCALE
LIGHTING SHALL BE AT EXISTING HANDHOLE THAT
SERVED EX UTILITY POLE SEE ELECTRICAL PLANS
5.1%5.1%5.1%5.1%4.4%
STREET TREE
(SPECIES, SPACING,
AND QUANTITY TBD)
DECORATIVE PED LIGHT POLE
PER ELECTRICAL PLANS (TYP)
TYPE 13 GUARDRAIL
PER WSDOT STD PLAN
C20.10-09
SEE DETAIL
1.9%
FOR DETAILED NE
10TH ST DRIVEWAY
IMPROVEMENTS
SEE DETAIL
C331
3
INSTALL NEW CURB AND GUTTER,
CONCRETE SIDEWALK, AND
ASPHALT PATCH FOR REMOVAL
OF EX DRIVEWAY CURB CUT
SEE DETAILS
EX WATER DISTRICT
90 WATER MAIN
14
'
C303
7
C303
8
C304
2
C304
2
C303
8
5'
20
'
C333
1 C333
2 C333
4
14 LF 12"
PVC @ 2.9%
SD C4 CB TYPE I
RIM 468.55
IE 465.62 12"(IN)N
IE 465.62 12"(OUT)SW
CONNECT TO EX SDMH
IE 465.20
SD C5 CB TYPE I
RIM 460.11
IE 456.00 12"(OUT)W
193 LF 12"
PVC @ 3.4%
46
5
4
6
3
46
4
46
6
46
7
46
8
461
460458459 461
460458459
CONNECT TO EX CB
IE 449.35
453.05(EX)
TC 453.50 (EX)
BC 453.00 (EX)
453.63(EX)5'46
8467
466465463
464
462456
456
457
4
6
2
467.50
468.05(EX)
467.31
467.23
467.26
465.88
465.78
TC 465.81
BC 465.31
2.
4
%
463.60
TC 463.98
BC 463.48
464.05
LAWN/HYDROSEED IN PLANTER
STRIP WITH SOIL BEING AMENDED
PER BMP T5.13. SEE DETAIL 6/C300.
ADJUST EX
HANDHOLE TO
FINISHED GRADE
2:1 SLOPE TO
EXISTING GRADE
PROTECT EX CHAINLINK
FENCE TO REMAIN
MATCH EX GRADE AT
PROPERTY LINE
WITHIN THIS 30-FT ROW
455.28(EX)
455.20(EX)
TC 455.64
BC 455.14
455.71
457.34
TC 457.72
BC 457.22
457.79
459.42
TC 459.80
BC 459.30
459.88
461.51
TC 461.89
BC 461.39
461.96
10
'
463.88
3+00 4+00 5+00 6+00 7+00 8+00
3+50 4+50 5+50 6+50 7+50 8+50
FOR DETAILED NE
10TH ST DRIVEWAY
IMPROVEMENTS
SEE DETAIL
C330
1
FOR DETAILED RAMP
IMPROVEMENTS
SEE DETAIL
N.E. 10TH ST.
GR
A
H
A
M
AV
E
N
.
E
.
HO
Q
U
I
A
M
AV
E
N
.
E
.
473
4
7
6
475
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C303
7
C332
1
9+00 10+00 11+00 12+00 13+00
9+50 10+50 11+50 12+50 13+5020
+
0
0
20
+
5
0
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
PROPERTY LINE
CONTOUR (INDEX)
CONTOUR
GRADE BREAK
SPOT ELEVATION
110
109.36
109
TC 109.86
BC 109.36
ASPHALT PAVEMENT
CONCRETE CURB
CONCRETE PAVEMENT
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
NE 10TH ST CIVIL SITE PLAN
BUILDING VESTIBULE
MA
T
C
H
L
I
N
E
-
S
E
E
A
B
O
V
E
R
I
G
H
T
MA
T
C
H
L
I
N
E
-
S
E
E
B
E
L
O
W
L
E
F
T
FOR DETAILED RAMP
IMPROVEMENTS SEE
DETAIL
ASPHALT PAVING
(RESIDENTIAL STREET SECTION)
SEE DETAIL (TYP)
C303
8ASPHALT PAVING
(RESIDENTIAL STREET SECTION)
SEE DETAIL (TYP)
C303
8
T-432602
TR
O
-
4
1
-
4
3
2
6
C330
4
ASPHALT THICKENED EDGE
WHERE NEW ASPHALT MEETS
EXISTING LANDSCAPING
SEE DETAIL
C300
5
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
STATIONING INTERSECTION
NE 10TH ST STA 13+17.1
HOQUIAM AVE NE STA 20+00
T-432602
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432623
TE
D
-
4
0
-
4
3
2
6
E
E
E
YELLOW PAINTED
PEDESTRIAN CURB
1.
5
%
HOQUIAM AVE. N.E.
N.
E
.
12
T
H
S
T
N.
E
.
11
T
H
P
L
N.
E
.
11
T
H
C
T
1
EX RECENTLY
INSTALLED CURB CUT
RAMPS TO REMAIN
47
0
458
459
45
7
45
8
45
9
457
5'
6.7'
1
4
3
3
NEW THERMOPLASTIC
CROSSWALK STRIPING PER
COR STANDARD PLAN 127
SEE DETAIL
C302
6
4" WIDE
PAINTED
STRIPE LINE
0.
6
7
'
2'
0.
6
7
'
3'
10'
28+00 29+00 30+00 31+00 32+00 33+00 33+18
27+50 28+50 29+50 30+50 31+50 32+50
HOQUIUM AVE. N.E.
(A DEDICATED PUBLIC RIGHT OF WAY)
HOQUIAM AVE. N.E.
N.
E
.
11
T
H
S
T
N.
E
.
10
T
H
P
L
471
22+00 23+00 24+00 25+00 26+00 27+00
22+50 23+50 24+50 25+50 26+50
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
PROPERTY LINE
CONTOUR (INDEX)
CONTOUR
GRADE BREAK
SPOT ELEVATION
110
109.36
109
TC 109.86
BC 109.36
ASPHALT PAVEMENT
CONCRETE CURB
CONCRETE PAVEMENT
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
HOQUIAM AVE NE STRIPING AND SIGNAGE PLAN
BUILDING VESTIBULE
MA
T
C
H
L
I
N
E
-
S
E
E
A
B
O
V
E
R
I
G
H
T
MA
T
C
H
L
I
N
E
-
S
E
E
B
E
L
O
W
L
E
F
T
PROTECT EX TREE ON
PRIVATE PROPERTY
PROTECT EX UTILITY
POLE AND GUY WIRE
KEYNOTES
1.INSTALL FLASHING BEACON POST PER CITY OF
RENTON STD PLANS 141.1 & 141.2 AND WSDOT
STD PLAN J-20.11 WITH THE FOLLOWING ON NORTH
SIDE OF POLE: S1-1 "SCHOOL CROSSING", RRFB-4R
FLASHER, W16-7P(L), AND PEDESTRIAN
PUSHBUTTON. SIGNS SHALL BE PER CURRENT
MUTCD. SEE ELECTRICAL PLANS.
2.INSTALL FLASHING BEACON POST PER CITY OF
RENTON STD PLANS 141.1 & 141.2 AND WSDOT
STD PLAN J-20.11 WITH THE FOLLOWING ON SOUTH
SIDE OF POLE: S1-1 "SCHOOL CROSSING", RRFB-4R
FLASHER, W16-7P(L), AND PEDESTRIAN
PUSHBUTTON. SIGNS SHALL BE PER CURRENT
MUTCD. SEE ELECTRICAL PLANS.
3.4" WIDE BLOCK OUT STRIPING. MATCH EX PATTERN
AND LAYOUT.
4.REMOVE EX TYPE 1Y & 2YY RPM'S FOR CENTERLINE
AS REQUIRED FOR CONDUIT TRENCH PATCHING
AND MOVING CROSSWALK. REPLACE WITH NEW
TYPE 1Y & 2YY RPM'S WITH TYPE 2YY BEING NEXT
TO CROSSWALK ONLY. MATCH EXISTING SPACING
AND PATTERN AND COORDINATE WITH CITY
INSPECTOR FOR FINAL LAYOUT IN FIELD.
T-432603
2
CONTRACTOR SHALL POTHOLE AND
VERIFY LOCATION AND DEPTH OF EX
ELECTRICAL AND TELEPHONE
CONDUITS IN THIS AREA
TE
D
-
4
0
-
4
3
2
6
T-432603
TR
O
-
4
1
-
4
3
2
6
DEVELOPMENT ENGINEERING
msippo 08/07/2025
condition of approval:
RRFB crossing shall be coordinated with city project review
managers post-permit issuance and be designed and
constructed in a manner that is satisfactory to city
development engineering and transportation operations
group. design shall incorporate necessary safety elements
including, but not limited to, photometric analysis of
crosswalk meeting city standards, protected islands to
reduce crossing distance, clear sight lines of beacons, ADA
requirements, and independent north/south and east/west
crossings.
R-432624
TE
D
-
4
0
-
4
3
2
6
E
E
E E E E E E
E SUBSD
SD
E
EE
E
E E E E E E E E E E E E E
SDSDSDSDSDSDSDSDSD
N.E. 10TH ST.
FI
E
L
D
AV
E
N
.
E
.
PROTECT EXISTING
TREE TO REMAIN
1.5'
5'
8.
5
'
EXISTING
2" GAS MAIN
EXISTING
POWER POLE
6'
470
471
4
6
9
4
6
8
466462463461460459457457
4
5
5
4554
5
4
POWER POC FOR NEW PEDESTRIAN SCALE
LIGHTING SHALL BE AT EXISTING HANDHOLE THAT
SERVED EX UTILITY POLE SEE ELECTRICAL PLANS
STREET TREE
(SPECIES, SPACING,
AND QUANTITY TBD)
DECORATIVE PED LIGHT POLE
PER ELECTRICAL PLANS (TYP)
467
14
'
3.7'
5'
3+00 4+00 5+00 6+00 7+00 8+00
3+50 4+50 5+50 6+50 7+50 8+50
N.E. 10TH ST.
GR
A
H
A
M
AV
E
N
.
E
.
HO
Q
U
I
A
M
AV
E
N
.
E
.
473
4
7
6
475
0.67'
0.67'
2'
9+00 10+00 11+00 12+00 13+00
9+50 10+50 11+50 12+50 13+5020
+
0
0
20
+
5
0
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
LEGEND
PROPERTY LINE
CONTOUR (INDEX)
CONTOUR
GRADE BREAK
SPOT ELEVATION
110
109.36
109
TC 109.86
BC 109.36
ASPHALT PAVEMENT
CONCRETE CURB
CONCRETE PAVEMENT
SCALE 1"=20'
0 10 20 40
HAZEN HIGH SCHOOL MODERNIZATION
NE 10TH ST STRIPING AND SIGNAGE PLAN
BUILDING VESTIBULE
MA
T
C
H
L
I
N
E
-
S
E
E
A
B
O
V
E
R
I
G
H
T
MA
T
C
H
L
I
N
E
-
S
E
E
B
E
L
O
W
L
E
F
T
EX RECENTLY
INSTALLED CURB CUT
RAMP TO BE REPLACED
NOTE:
CONTRACTOR SHALL INCLUDE ALLOWANCE FOR THE
FOLLOWING RELATED TO THE STREET IMPROVEMENTS
FROM THE INTERSECTION OF FIELD AVE NE AND NE
10TH STREET TO THE WEST:
IRRIGATION IN PLANTER STRIP BEHIND SIDEWALK
LAWN/HYDROSEED IN PLANTER STRIP WITH SOIL
BEING AMENDED PER BMP T5.13. SEE DETAIL 6/C300.
NEW THERMOPLASTIC
CROSSWALK STRIPING
PER COR STANDARD
PLAN 127 SEE DETAIL
C302
6
ASPHALT PAVING
(RESIDENTIAL STREET SECTION)
SEE DETAIL (TYP)
C303
8ASPHALT PAVING
(RESIDENTIAL STREET SECTION)
SEE DETAIL (TYP)
C303
8
T-432604
TE
D
-
4
0
-
4
3
2
6
T-432604
TR
O
-
4
1
-
4
3
2
6
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432625
TE
D
-
4
0
-
4
3
2
6
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
SITE DETAILS
COMPACTED SUBGRADE
(MIN 95% MAXIMUM DRY DENSITY)
CRUSHED SURFACING
BASE COURSE
CRUSHED SURFACING
TOP COURSE
CEMENT CONCRETE PAVEMENT
PER PROJECT SPECIFICATION
SECTION 321313
6"
2"
4"
FLUSH WITH ADJACENT
SURFACES ON ALL
SIDES
BROOM FINISH
NOTES:
1.DEPTHS ARE COMPACTED THICKNESS
2.SEE LANDSCAPE PLANS FOR CONCRETE SCORING AND JOINTING.
3.CEMENT CONCRETE SHALL BE CLASS 4000
#4 BARS AT 12"
O.C. EACH WAY
2" CLR
(TYP)
On-Site Concrete Pavement 4NTS
NOTES:
DEPTHS ARE COMPACTED THICKNESS
HMA CLASS 1/2"
* COMPACTED CRUSHED
SURFACING TOP COURSE
COMPACTED CRUSHED
SURFACING BASE COURSE
12"
SAWCUT TACK AND
MATCH EX ASPHALT
FULL DEPTH
EX UNDISTURBED PAVEMENT
SUB-BASE MUST BE COMPACTED TO
95% MAX DENSITY PER ASTM D 1557
EXISTING ASPHALT
COMPACTED STRUCTURAL FILL
SUB-BASE (OR EXISTING SUBGRADE)
PER GEOTECHNICAL ENGINEER
4"
*2"
4"
12
"
M
I
N
3"
4"
12
"
M
I
N
2"
*4"
12
"
M
I
N
HE
A
V
Y
D
U
T
Y
ST
A
N
D
A
R
D
D
U
T
Y
WA
L
K
/
T
R
A
C
K
COMPACTED SUBGRADE
95% ASTM D1557
COMPACTED CRUSHED
SURFACING TOP COURSE
CEMENT CONCRETE PAVEMENT
PER PROJECT SPECIFICATION
SECTION 321313
4"
4"
BROOM FINISH
NOTE:
1.DEPTHS ARE COMPACTED THICKNESS
2.CEMENT CONCRETE SHALL BE CLASS 3000
3.DUMMY JOINTS CONSISTING OF 3/16" BY 2" PREMOLDED JOINT
MATERIAL SHALL BE PLACED AT 15 FOOT INTERVALS
4.SEE LANDSCAPE PLANS FOR CONCRETE SCORING AND JOINTING.
1/4" EDGED
GROOVE 2% SLOPE (1/4" DROP PER 1')
On-Site Concrete Sidewalk 3NTS
On-Site Asphalt Pavement 7NTS
Gravel Path 8NTS
Compost Amended Soil BMP T5.13 6NTS
COMPACTED SUBGRADE
(MIN 95% MAXIMUM DRY DENSITY)
CRUSHED SURFACING
BASE COURSE
CRUSHED SURFACING
TOP COURSE
2"
4"
NOTE:
1.DEPTHS ARE COMPACTED THICKNESS
24" MIN
ASPHALT THICKENED EDGE
12"14"
4"
MI
N
2" MIN
1" MIN
TAPERED EDGE
FINISHED GRADE FINISHED LANDSCAPING GRADE
ASPHALT PAVING
SEE DETAIL
SUBGRADE
NOTE:
1.FINISHED GRADE OF LANDSCAPING SHALL BE 1" MINIMUM BELOW THE GRADE OF
PAVEMENT SUCH THAT DEBRIS/PLANTINGS WILL NOT OBSTRUCT DRAINAGE FLOW
Ethafoam Pad 1NTS
Asphalt Thickened Edge 5NTS
5.5"
6.5"
6"
PAVEMENT
FACE OF CURB
R1"
R0.5"
FINISH GRADE
8.25"
16
"
0.5"
TOP OF CURB AT
DRIVEWAY APPROACH
NOTE:
CONTRACTOR SHALL
CONFORM TO WSDOT
SPEC. 8-04.3
On-Site Vertical Curb 10NTS
12"
(TYP)
12"
(TYP)
PE
R
P
L
A
N
NOTES:
1.STRIPING COLOR SHALL BE "WHITE" AND PAINTED PER PROJECT SPECIFICATIONS
2.STRIPING DIMENSIONS SHALL MEET MUTC SPECIFICATION 3B-18 AND FIGURE 3-14C.
On-Site Crosswalk Striping 9NTS
5"
10"
ASPHALT PAVEMENT
SEE DETAIL
FINISH GRADE
R112"
6"
1"
R11 2"
R1"
DEPTH OF THROUGH JOINT #3 (2'-8") EPOXY
COATED REINFORCING
BARS @ 2'-4" O.C.
SEE NOTE 1
NOTE:
1.CONTRACTOR MAY USE EPOXY BONDING AGENT, IN PLACE OF #3
DEFORMED BARS.
2.CONTRACTOR SHALL CONFORM TO WSDOT SPEC. 8-04.3
2"
1"
R1"
C300
7
On-Site Extruded Curb 11NTS
R-432624
TE
D
-
4
0
-
4
3
2
6
LE
S
S
T
H
A
N
1
2
"
C
L
E
A
R
NEW UTILITY
NEW UTILITY
EXPANDED POLYSTYRENE
FOAM PAD CUT TO
SUPPORT TOP PIPE
ETHAFOAM PAD SHALL BE OUTSIDE PIPE DIAMETER X OUTSIDE PIPE
DIAMETER X3 INCHES WHERE OUTSIDE DIAMETER REFERS TO THE
LARGER PIPE
R-432626
DEVELOPMENT ENGINEERING
msippo 08/07/2025
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
SITE DETAILS
INSTALL BOLLARD COVER
ON ALL BOLLARDS
SEE DETAIL 8/C302
Bollard Detail (Removeable)10NTS
Bollard Detail (Non-Removeable)6NTS
INSTALL BOLLARD COVER
ON ALL BOLLARDS
SEE DETAIL 8/C302
Parallel Curb Ramp 8NTS
2.
5
'
3.
3
'
3"
6"Ø SCH. 20 GALV.
STEEL PIPE FILLED
W/ CONCRETE
FINISH GRADE
PAVEMENT AS
SHOWN ON
PLANS
NOTES:
FIRE HYDRANTS:
1.LOCATE POSTS 3' FROM HYDRANT. DON'T
BLOCK HYDRANT PORTS
2.PIPE TO RECEIVE ONE PRIME COAT AND
TWO COATS OUTDOOR OIL BASE ENAMEL
(SAME COLOR AS FIRE HYDRANT) FOR
EXPOSED PORTION OF BOLLARD ONLY.
PSE TRANSFORMER:
3.LOCATE POSTS 3' FROM FRONT AND BACK
AND 18" FROM SIDES OF TRANSFORMER.
4.PIPE TO RECEIVE ONE PRIME COAT AND
TWO COATS OUTDOOR OIL BASE ENAMEL -
TRAFFIC YELLOW - FOR EXPOSED
PORTION OF BOLLARD ONLY.
5.INSTALLATION OF GUARD POSTS MUST BE
COMPLETED BEFORE THE PRIMARY CABLE
IS INSTALLED AND ENERGIZED.
FIXED BOLLARD
CEMENT CONCRETE
CLASS 3000
CONCRETE DOME TOP
BACKFILL HOLES
WITH CONCRETE
EXISTING SUBGRADE
COMPACTED TO
95% MAX DENSITY
PER ASTM D 1557
6"6"6"
Pipe Bollard 11NTS
NOTE: NOT FOR
FIRE ACCESS
NOTE: NOT FOR
FIRE ACCESS
C
D
3/16"
B
A
A B
DETECTABLE WARNING PATTERN AREA
SHALL BE YELLOW, IN COMPLIANCE WITH
WSDOT STANDARD SPEC. 8-14.3(3)
A 1 5/8"2 3/8"
B 5/8"1 1/2"
C 7/16"3/4"
D 7/8"1 7/16"
MIN MAX
Truncated Domes 12NTS
T-432603
TR
O
-
4
1
-
4
3
2
6
T-432605
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432627
TE
D
-
4
0
-
4
3
2
6
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
SITE DETAILS
Bollard Cover 8NTS
Crosswalk and Stop Bar Pavement Markings and Notes 6NTS
Perpendicular Curb Ramp 9NTS
NOTE: NOT FOR
FIRE ACCESS
T-432604
TR
O
-
4
1
-
4
3
2
6
T-432606
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432628
TE
D
-
4
0
-
4
3
2
6
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
SITE DETAILS
Cement Concrete Driveway Entrances and Notes and Details 6NTS
Cement Concrete Sidewalk 7NTS
Curb and Gutter Replacement 8NTS
Cement Concrete Curbs 9NTS
4' (TYP)
1'
SALVAGE AND REMOVE EX BRICK
PAVER BANDS TO BE REINSTALLED
AS REQUIRED TO CONSTRUCT NEW
LIBRARY FOUNDATIONS.
BRICKS ARE SAND SET AND SHALL
BE PLACED ON A COMPACTED 1"
MINIMUM SAND BEDDING (TYP)
LIBRARY
LIBRARY IMPROVEMENTS
PER ARCH'L PLANS
DIMENSIONS INDICATED ARE
APPROXIMATE. CONTRACTOR
SHALL VERIFY AND DOCUMENT
EXISTING CONDITIONS PRIOR TO
ANY DEMOLITION, SALVAGE, AND
REPLACEMENT OF MATERIALS
1' (TYP)
9'
-
1
"
5'-0"
(TYP)
REMOVE AND REPLACE EX
CONCRETE SIDEWALK AS
REQUIRED TO CONSTRUCT
NEW LIBRARY FOUNDATIONS
SEE DETAIL (TYP)
COURTYARD DRAWING FROM ORIGINAL
HAZEN HIGH SCHOOL PROJECT RECORD
DRAWINGS DATED 1/11/1967 Existing Courtyard Revisions 10Scale: 1/8" = 1'-0"
C300
3
KEYNOTE:
1.CONTRACTOR SHALL POTHOLE AND VERIFY
EX EX AREA DRAIN AND PIPE LOCATION,
DEPTH, AND SIZE, AND NOTIFY CIVIL
ENGINEER WITH ELEVATION INFORMATION
AND IF ANY CONFLICTS WITH PROPOSED
FOUNDATIONS.
2.4" SD PER 1967 RECORD DRAWINGS.
CONTRACTOR SHALL VERIFY PIPE
LOCATION AND DEPTH PRIOR TO
CONSTRUCTION OF PROPOSED LIBRARY
FOUNDATIONS AND NOTIFY CIVIL
ENGINEER AND ARCHITECT IF CONFLICTS.
LEGEND
FTG FTGFOOTING DRAIN
STORM DRAINAGE PIPE SD
INLET PROTECTION IP
IP
SD SD
SD
SD
SD
SD
SD
SD
FT
G
FT
G
FT
G
FT
G
FT
G
FT
G
FT
G
FT
G
FT
G
FT
G
FT
G
INSTALL CB
PROTECTION
SEE DETAIL
C110
7
1
2
4" PERFORATED
FOOTING DRAIN
SEE DETAIL
C312
2
INSTALL ANTI-SEEP COLLAR
AT PERF TO SOLID PIPE
CONNECTION PRIOR TO
TYING INTO EX AREA DRAIN
SEE DETAIL
C312
1
C303
9
SEE DETAIL
T-432605
TR
O
-
4
1
-
4
3
2
6
T-432607
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432629
TE
D
-
4
0
-
4
3
2
6
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
SITE DETAILS
Not Used 4NTS
Not Used 3NTS
Not Used 5NTS
Single Direction Curb Ramp 1NTS
Beam Guardrail Type 31 2NTS
T-432606
TE
D
-
4
0
-
4
3
2
6
T-432608
TR
O
-
4
1
-
4
3
2
6
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432630
TE
D
-
4
0
-
4
3
2
6
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DRAINAGE DETAILS
Rectangular Frame 1NTS
Rectangular Vaned Grate (Right -of-Way)2NTS
Catch Basin Type II 3NTS
Catch Basin Type I 4NTS
Flow Control Structure 5NTS
Typical Trench and Backfill 6NTS
Pipe Zone Bedding and Compaction 7NTS
StormTrap Vent Pipe Installation 8NTS
R-432629
TE
D
-
4
0
-
4
3
2
6
VARIES PER PLANVARIES PER PLAN
12" VENTALATION PIPE
INSTALL CLEANOUT
COVER SEE DETAIL FINISHED GRADE
VARIES
PER PLAN
1'-6"
C311
1
R-432631
StormTrap Vent Pipe Installation 8NTS
DEVELOPMENT ENGINEERING
msippo 08/07/2025
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DRAINAGE DETAILS
Storm Round Frame and Cover 2NTS
Tee Section Shear Gate 3NTS
Misc Details for Drainage Structures 7NTS
Cleanout 1NTS
Zoeller Sump Pump Model 57 Detail 5NTS
SUMP AND PUMP, FOR
PUMP INFORMATION
SEE DETAIL
C311
5
Sump Pump Detail Schematic 6NTS
Not Used 4NTS
R-432630
TE
D
-
4
0
-
4
3
2
6
R-432632
DEVELOPMENT ENGINEERING
msippo 08/07/2025
12" SD
IE OUT 470.36
COMPACTED SUBGRADE
FINISHED SURFACE PER LANDSCAPE
77"
45
"
BOTTOM OF EXCAVATION 469.50
BOTTOM OF CHAMBER 470.25
TOP OF CHAMBER 474.00
(TOP OF LIVE STORAGE)
9" DEAD
STORAGE
6" FREEBOARD
FIELD SECTION
(PER LANDSCAPE)
6"
43
.
7
"
L
I
V
E
S
T
O
R
A
G
E
GEOTEXTILE FABRIC
PER LANDSCAPE
PLANS AND SPECS
BOTTOM OF FIELD SECTION 475.00
PLAY SURFACE 477.00
1'
GRAVEL
MIRAFI 140N GEOTEXTILE FABRIC
ABOVE IMPERVIOUS LINER PER
MANUFACTURER SPECIFICATIONS
30 MIL PVC IMPERVIOUS
LINER PER MANUFACTURER
SPECIFICATIONS
MIRAFI 180N GEOTEXTILE FABRIC
BELOW IMPERVIOUS LINER PER
MANUFACTURER SPECIFICATIONS
LINER AND GEOTEXTILES
TO EXTEND TO TOP OF
GRAVEL ON ALL SIDES OF
CHAMBER EXCAVATION
6" GRAVEL BASE
BOTTOM OF DEAD
STORAGE 443.50 BOTTOM OF
VAULT 443.00 BOE 442.50
1'
6" DEAD STORAGE
BOTTOM OF LIVE
STORAGE 444.00
6" FREEBOARD
TOP OF VAULT
454.00
TOP OF LIVE
STORAGE 453.00
TOP OF FREEBOARD
453.50
9'
L
I
V
E
ST
O
R
A
G
E
MAX FINISH GRADE 457.64
MIN FINISH GRADE 455.39
FINISH GRADE
VARIES
GRAVEL
MIRAFI 140N
GEOTEXTILE
30 MIL PVC LINER
MIRAFI 180N
GEOTEXTILE
COMPACTED SUBGRADE
PER LANDSCAPE
SPECIFICATIONS
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DRAINAGE DETAILS
Rectangular Herringbone Grate (On-Site Only)8NTS
Downspout Connection with Flush Cleanout 9NTS
Modular Precast Vault Section (Baseball Field)10Scale: 1"=5' V. 1"=10' H
StormTech MC-3500 Cross Section (Softball Field)6NTS
OPEN DISCHARGE INTO
DETENTION CHAMBER TRENCH
SYNTHETIC TURF
SECTION PER
LANSCAPE PLANS
FLATDRAIN LATERAL
PER LANDSCAPE
SUBDRAINAGE PLANS
PROVIDE POSITIVE
SUBGRADE SLOPE TO
DETENTION CHAMBER
Field Subdrainage Chamber Connection 11NTSVA
R
I
E
S
P
E
R
ST
R
U
C
T
U
R
A
L
VARIES PER PLAN
FFE PER PLAN
2"
BUILDING WALL PER ARCH'L PLANS
3"x4" RECTANGULAR SHEET METAL DOWNSPOUT
UNLESS OTHERWISE NOTED PER ARCH'L PLANS
14
"
DEBRIS EVACUATOR (CLEANOUT)
WITH SWING DOOR PER ARCH'L
PIEDMONT (OR APPROVED EQUAL) STAINLESS STEEL
3"x4" RECTANGULAR DOWNSPOUT ADAPTER WITH
RECTANGULAR TO ROUND BOTTOM TRANSITION
FINISHED GRADE
PER PLAN
HARDSCAPE WHERE
OCCURS PER PLAN
4" SD PER PLANS
4" SCHED 40 PVC ADAPTER
4" 45° OR 90° BEND
PERF FOOTING DRAIN
SEE DETAIL
STORM
TIGHTLINE PIPE
PER PLANS
4" WYE PER
PLANS
NOTES:
1.DOWNSPOUT LOCATIONS ARE PER
ARCHITECTURAL PLANS
2.PIEDMONT DOWNSPOUT ADAPTER AND 4"
PVC ADAPTER TO BE INSTALLED PRIOR TO
CONCRETE SETTING BLOCK BEING
POURED AND BUILDING DOWNSPOUT
CONNECTED.
4" PVC TEE
4" STORM DRAIN
CLEANOUT FLUSH W/
FINISHED GRADE
COMPACTED BACKFILL SLOPE MEETING
GRADATION REQUIREMENTS FOR
STRUCTURAL FILL (SEE NOTE 2)
SLOPE TO DRAIN AWAY
FROM STRUCTURE
6"
BUILDING WALL. SEE
STRUCTURAL PLANS
GRAVEL BACKFILL FOR DRAINS
PER PROJECT SPECIFICATIONS
BUILDING FOOTING
SEE STRUCTURAL
PLANS
6" MIN 6" MIN
4" SDR 35 PVC PERF PIPE EXTERIOR
USE ONLY CONNECT TO STORM
CONVEYANCE SYSTEM. SURROUND
W/ DRAIN ROCK AS SHOWN
WRAP WITH NON-WOVEN
SEPARATION FILTER FABRIC
NOTES:
1.PIPE SHALL BE PLACED NO LOWER THAN 3" BELOW BOTTOM OF FOOTING
2.STRUCTURAL FILL SHALL MEET THE REQUIREMENTS OF SECTION 31 22 00
OF THE PROJECT SPECIFICATIONS
Footing Drain with Filter Fabric 2NTS
SECTION A-A
PLAN VIEW
UTILITY
LINE
(DIAMETER
VARIES)
A
UT
I
L
I
T
Y
L
I
N
E
UT
I
L
I
T
Y
L
I
N
E
A
GRADE
TRENCH WIDTH
ANTI-SEEP
COLLAR
12
"
6"
12
"
6"
18
"
TR
E
N
C
H
DE
P
T
H
TRENCH WIDTH
ANTI-SEEP COLLAR.
CLASS B CONCRETE.
Anti-Seep Collar 1NTS
R-432631
TE
D
-
4
0
-
4
3
2
6
R-432633Field Subdrainage Chamber Connection 11NTS
DEVELOPMENT ENGINEERING
msippo 08/07/2025
SD A1 - CONTROL STRUCTURE
2'
2'
54"
12" SD OUTLET
IE 444.00
12" SD INLET
IE 444.00
SUPPORT (2 MIN.)
SEE DETAIL 'A'
SUPPORT (2 MIN.)
SEE DETAIL 'A'
LEVELING BRICK OR
CONCRETE COLLAR
AS NECESSARY
2'
0.5'
OVERFLOW ELEVATION 453.00
ORIFICE 1
IE 442.00
1"
SEE DETAIL 'B'
ORIFICE 2
IE 449.40
0.875" = 7/8"
SEE DETAIL 'D'
12" RISER
PIPE
RIM 455.09
TYPE 2
CATCH BASIN
SEE DETAILS
ORIFICE 3
IE 450.70
0.75" = 3/4"
SEE DETAIL 'D'
12" SD
INLET
12" SD
OUTLET
1/2"
RECTANGULAR WEIR 451.70
C310
3
C310
5
SD C1 - CONTROL STRUCTURE
2'
2'
54"
12" SD OUTLET
IE 470.36
12" SD INLET
IE 470.36
SUPPORT (2 MIN.)
SEE DETAIL 'A'
SUPPORT (2 MIN.)
SEE DETAIL 'A'
2'
0.5'
RECTANGULAR WEIR 473.05
ORIFICE 1
IE 468.36
0.875"= 7/8"
SEE DETAIL 'B'
ORIFICE 2
IE 471.98
0.5" = 1/2"
SEE DETAIL 'D'
12" RISER PIPE
RIM 476.84
OVERFLOW ELEVATION 474.00
TYPE 2
CATCH BASIN
SEE DETAILS
C310
3
C310
5
1/4"
12" SD
OUTLET
12" SD
INLET
FLOW CONTROL STRUCTURE
PVC PIPE & CROSS
DEFORMED 38" STEEL ROD (SS
OR ALUMINUM) LENGTH TO FIT
WIRE ROPE CLIP (SS)
CINCH ANCHOR
FLOW CONTROL
STRUCTURE
NON-SHRINK GROUT
1'-0" MAX
PVC PIPE STUB
SHIELDED
COUPLING
GASKET (TYP)
PVC ADAPTER W/ DOUBLE
GASKET AND ADHESIVE
BONDED SAND FINISH ON
EXTERIOR, MIN 7" LONG
CAULK SPACE BETWEEN
PVC ADAPTER AND PIPE STUB
CONTROL DEVICE
ASSEMBLY TO BE
REMOVABLE FROM
INSIDE THE FCS
SHEAR GATE
SEE DETAIL 'C'
1'
-
0
"
INVERT
PVC PIPE
CROSS
ORIFICE 1 DIAMETER*
ORIFICE PLATE
4 1/2"
NOTES:
1.PVC PIPE MUST BE SCHEDULE 40, PER ASTM 1785.
2.*CONSTRUCTION DRAWINGS MUST PROVIDE ELEVATION AND DIAMETER FOR
ORIFICE 1 AND ORIFICE 2 AND DIMENSIONS AND ELEVATION FOR THE
BOTTOM OF THE V-NOTCH WEIR AND ELEVATION FOR OVERFLOW.
3.FIELD CHANGES TO DETENTION PIPE INVERT AND SLOPE REQUIRE
CONFIRMATION FROM THE ENGINEER OF RECORD THAT THE CONSTRUCTION
DRAWING ELEVATIONS FOR THE FLOW CONTROL DEVICE ASSEMBLY STILL
MEET THE DESIGN REQUIREMENTS.
DETAIL A: PIPE SUPPORT DETAIL
DETAIL B: CONNECTION &
CONTROL DEVICE
WELDED GATE
ASSEMBLY TO PIPE
LIFT GATE AND PIPE
LIFT GATE
CONTROL ROD
NEOPRENE
GASKET
DETAIL C: LIFT GATE ASSEMBLY
ORIFICE PLATE WELDED
TO STUB ORIFICE
ELBOW STAND PIPE WALL
STUB WELDED TO STAND PIPE
IE PER PLANS
BAND ELBOW WITH REMOVABLE
WATER TIGHT COUPLING
6"
DETAIL D: SECONDARY ORIFICE
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DRAINAGE DETAILS
Not Used 5NTS
Control Structure Details 1NTS
Control Structure C1 (Softball Field)3Scale: 1"=2'
Control Structure A1 (Baseball Field)2Scale: 1"=2'
REFERENCE CITY OF RENTON CONTROL
STRUCTURE DETAIL FOR ADDITIONAL INFORMATION
SEE DETAIL 5/SHEET C310
REFERENCE CITY OF RENTON CONTROL
STRUCTURE DETAIL FOR ADDITIONAL INFORMATION
SEE DETAIL 5/SHEET C310
Not Used 4NTS
R-432632
TE
D
-
4
0
-
4
3
2
6
R-432634
DEVELOPMENT ENGINEERING
msippo 08/07/2025
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DRAINAGE DETAILS
MC-3500 StormTech 1NTS
R-432633
TE
D
-
4
0
-
4
3
2
6
R-432635MC-3500 StormTech 1NTS
DEVELOPMENT ENGINEERING
msippo 08/07/2025
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DRAINAGE DETAILS
StormTrap Details 1NTSNOTE: VAULT PENETRATIONS FOR INLET AND OUTLET PIPES,
AND ALL NECESSARY VENTS AND LIDS TO BE COORDINATED
WITH STORMTRAP PRIOR TO ORDER PLACEMENT
R-432635
TE
D
-
4
0
-
4
3
2
6
R-432636StormTrap Details 1NTS
DEVELOPMENT ENGINEERING
msippo 08/07/2025
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DRAINAGE DETAILS
StormTrap Details 1NTS
R-432636
TE
D
-
4
0
-
4
3
2
6
StormTrap Details 1NTS
R-432637
DEVELOPMENT ENGINEERING
msippo 08/07/2025
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DRAINAGE DETAILS
Modular Wetland Structure SD A2 1NTS
Modular Wetland Structure SD C2 2NTS
CDS Seperator SD B2 4NTS
Not Used 3NTS
R-432637
TE
D
-
4
0
-
4
3
2
6
R-432638
DEVELOPMENT ENGINEERING
msippo 08/07/2025
FIRE HYDRANT CONNECTION
Scale: 1"=5' V. 1"=10' H
465
470
475
480
465
470
475
480
PROPOSED FIRE
HYDRANT
ASSEMBLY
CO
N
N
E
C
T
I
O
N
T
O
E
X
10
"
W
A
T
E
R
M
A
I
N
(1
)
1
0
X
6
"
T
E
E
(
M
J
x
F
L
)
(1
)
6
"
G
A
T
E
V
A
L
V
E
(
F
L
x
M
J
)
W/
T
H
R
U
S
T
B
L
O
C
K
I
N
G
32 LF 6" DI CL52
3.5'
(ASSUMED)
EX 15' WATER
EASEMENT REC. NO.
20060303000926
NEW 15-FT WATER EASEMENT
KC REC NO.___________
EX GRADE (TYP)
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
UTILITY DETAILS
Tapping Tee 1NTS
Fire Hydrant Assembly 2NTS
Concrete Thrust Blocking 3NTS
Connection To Water Main 4NTS
Fire Hydrant Connection 7NTS
W-432602
Fire Hydrant Assembly Pavement Marker 5NTS
WT
R
-
2
7
-
4
3
2
6
Fire Hydrant Assembly Shear Block 6NTS
Fire Hydrant Connection 7NTS
W-432602
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432639
TE
D
-
4
0
-
4
3
2
6
GROUND SOURCE PIPING
SCALE: 1" = 5'
455
460
465
470
475
455
460
465
470
475
EX GRADE
EX SCHOOL
BUILDING
EX ELECTRICAL
(RECORD)
EX 15'
WATER
EASEMENT
EX 10" COR
WATER (RECORD)
IE 457.98
PROPOSED 10" GROUND
SOURCE PIPING
ASSUMED EXISTING
UTILITY ELEVATIONS.
CONTRACTOR TO
POTHOLE
5.
4
'
CONCRETE RETAINING WALL
AND FOOTINGS INCLUDING
TOP OF WALL ELEVATIONS
SEE STRUCTURAL PLANS
EX 10" COR WATER
(PER CONTRACTOR)
IE 457.98
1.26'
UTILIZE ETHAFOAM PAD
FOR CROSSINGS LESS
THAN 12"
SEE DETAIL
C300
1
1.26'
0'-4"
4.
5
'
GROUND SOURCE
PIPING
CROWN 459.17
GROUND SOURCE
PIPING
CROWN 456.71
GROUND SOURCE
PIPING
CROWN 456.71
EX ELECTRICAL
(RECORD)
GROUND SOURCE
PIPING
IE 457.79
3'-2 1/4"
GROUND SOURCE
PIPING
IE 458.31
EX 8" SEWER
CROWN 457.23
EX 12" STORM
CROWN 454.56
PROPOSED
ELECTRICAL
EX IRRIGATION
(RECORD)
IE 459.56
1'-1/4"
BUILDING FACE ALONG PROPOSED ENCLOSURE
SCALE: 1" = 5'
455
460
465
470
475
480
455
460
465
470
475
480
TOP OF
HILL/STAIRCASE
EX CONCRETE PAD AT
MECHANICAL DOOR
PROPOSED FENCING
ENCLOSURE FOR
ELECTRICAL YARD
PER PLAN
X
X
X
16' PROPOSED EXTENTS
OF ELEC EQUIPMENT
X
X
X
EX GRADEWALL HEEL TO
CONTINUE BEYOND
THE STAIRS
WALL HEEL TO
CONTINUE BEYOND
THE STAIRS
CONCRETE RETAINING
WALL AND FOOTING
INCLUDING TOP OF
WALL ELEVATIONS
SEE STRUCTURAL PLANS
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
UTILITY PROFILES AND SECTIONS
R-432639
TE
D
-
4
0
-
4
3
2
6
R-432640
DEVELOPMENT ENGINEERING
msippo 08/07/2025
STORM PROFILE A
Scale: 1"=5' V. 1"=20' H
425
430
435
440
445
450
455
460
465
425
430
435
440
445
450
455
460
465
STORM PROFILE B
Scale: 1"=5' V. 1"=20' H
445
450
455
460
465
445
450
455
460
465
EX GRADE (TYP)
EX GRADE (TYP)11 LF 12"
PVC @ 2.3%
SD B2 CB TYPE II - 48"
CONTECH CDS2015-4-C
RIM 456.03
IE 452.25 12"(IN)S
IE 452.25 12"(OUT)NE
SEE DETAIL
SD B1 CB TYPE I
RIM 456.06
IE 453.34 8"(IN)E
IE 453.00 12"(OUT)N
32 LF 12"
PVC @ 2.3%
DETENTION
OUTLET
IE 444.00
DETENTION INLET
IE 452.00
STORMTRAP MODULAR
PRECAST DETENTION
SYSTEM SEE SHEET C203
STORMTRAP MODULAR
PRECAST DETENTION
SYSTEM SEE SHEET C203
SD A5 CB TYPE I
RIM 431.56
IE 428.54 12"(IN)E
IE 428.54 12"(IN)S(EX)
IE 428.54 12"(OUT)N(EX)
SD A4 CB TYPE II - 48"
RIM 434.84
IE 430.11 12"(IN)NE
IE 430.11 12"(OUT)W
SD A3 CB TYPE II - 48"
RIM 455.51
IE 440.39 12"(IN)N
IE 440.39 12"(OUT)SW
SD A1 CB TYPE II - 54"
RIM 455.09
IE 444.00 12"(IN)NE
IE 444.00 12"(OUT)S
20 LF 12"
PVC @ 0.0%
16 LF 12"
PVC @ 10.0%
124 L
F
1
2
"
P
V
C
@
8
.
3
%
SD A2 MODULAR WETLAND
RIM 455.54
IE 443.76 12"(IN)N
IE 442.26 12"(OUT)S
SEE DETAIL
C318
1
125 LF 12" PVC @ 1.5%
12 LF 12"
PVC @ 2.0%
444 LF 8" PVC @ 1.4%8" SDCO
RIM 461.26
IE 459.76 8"(OUT)W
C318
4
BASEBALL FIELD UNDERDRAIN
COLLECTOR PIPE PER
LANDSCAPE PLANS
5.3'
WE
S
T
P
R
O
P
E
R
T
Y
L
I
N
E
(D
U
V
A
L
L
A
V
E
N
E
)
EX CURB AND GUTTER
EX ASPHALT
PAVEMENT
EX 8"
STORM
CONTRACTOR TO POTHOLE
AND VERIFY UTILITY
CROSSINGS PRIOR TO THE
START OF STORM
INSTALLATION AND NOTIFY
ENGINEER OF CONFLICTS
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DRAINAGE PROFILES
R-432640
TE
D
-
4
0
-
4
3
2
6
R-432641
DEVELOPMENT ENGINEERING
msippo 08/07/2025
STORM PROFILE C
Scale: 1"=5' V. 1"=20' H
445
450
455
460
465
470
475
480
485
445
450
455
460
465
470
475
480
485
FINISHED
GRADE (TYP)
EX GRADE (TYP)
10 LF 12" PVC @ 5.0%
SD C1 CB TYPE II - 54"
RIM 476.84
IE 470.36 12"(IN)NE
IE 470.36 12"(OUT)W
W/ CONTROL STRUCTURE
30 LF 12"
PVC @ 0.0%
EX 8" SEWER
IE 446.37
STORMTECH
CHAMBERS MC-3500
SEE SHEET C205
12" DETENTION
OUTLET
IE 470.36
SD C2 MODULAR WETLAND
RIM 476.56
IE 469.87 12"(IN)E
IE 468.37 12"(OUT)W
SEE DETAIL
32 LF 1
2
"
PVC @ 5
.
8
%
C318
2
SD C3 CB TYPE I
RIM 471.37
IE 466.53 12"(IN)E
IE 466.53 12"(OUT)S
31 LF 12"
PVC @ 2.9%
SD C4 CB TYPE I
RIM 468.55
IE 465.62 12"(IN)N
IE 465.62 12"(OUT)SW
CONNECT TO
EX SDMH
IE 465.20
14 LF 12"
PVC @ 2.9%
SO
U
T
H
P
R
O
P
E
R
T
Y
L
I
N
E
(N
E
1
0
T
H
S
T
R
E
E
T
)
15.5'
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DRAINAGE PROFILES
R-432641
TE
D
-
4
0
-
4
3
2
6
R-432642
DEVELOPMENT ENGINEERING
msippo 08/07/2025
HOQUIAM AVE. N.E.
10.8'40'8.9'
471.56(EX)471.95
DRIVEWAY TYPE C3 PER
COR STANDARD PLAN 104
SEE DETAIL
C303
6
TC 472.04
BC 471.54
TC 471.83
BC 471.33
TC 471.99 (EX)
BC 471.49 (EX)
TC 471.52 (EX)
BC 471.02 (EX)
471.45 471.24
1.
2
%
1.
5
%
2.6%
2.5%
1.
5
%
1.
5
%
3.9%
3.5%
471
12
.
1
'
CHANNELIZATION ARROW
SEE DETAIL (TYP)
C302
6
STOP BAR
SEE DETAIL
C302
6PROTECT EX STOP
SIGN AND POST
CONCRETE
CURB (TYP)
PROTECT EX BUSES ONLY
AND STUDENT DROP OFF /
PICK UP SIGN AND POST
ASPHALT PAVING
(ARTERIAL STREET SECTION)
SEE DETAIL
C303
8
47
2
2.
0
%
14'
471.97(EX)
472.08(EX)
472.07
TC 471.49 (EX)
BC 471.09 (EX)
TC 471.83 (EX)
BC 471.38 (EX)
25+00
24+50
N.E. 10TH ST.
9'30'5'
DRIVEWAY TYPE C3 PER
COR STANDARD PLAN 104
SEE DETAIL
C303
6
475.25477.05
475.09476.32
TC 476.77 (EX)
BC 476.27 (EX)
TC 475.47 (EX)
BC 474.97 (EX)
TC 475.67
BC 475.17
TC 476.89
BC 476.39
5'
1.
5
%
1.
5
%
47
6
4
7
6
475
7.3%
7.1%
1.
5
%
1.8%
1.
5
%
1.7%
PROTECT EX STOP
SIGN AND POST
CONCRETE
CURB (TYP)
ASPHALT PAVING
(RESIDENTIAL STREET SECTION)
SEE DETAIL
C303
8
PROTECT EX STUDENT
DROP OFF / PICK UP
SIGN AND POST
477.56(EX)
477.42(EX)
2.
8
%
15'
BC 474.77 (EX)
TC 475.18 (EX)
BC 476.53 (EX)
TC 476.97 (EX)
474.74(EX)
474.56(EX)
3.
4
%
15'
47
5
12+0011+50
SD SD
HOQUIAM AVE. N.E.
6.5'5'40'8.5'
472.76(EX)
TC 472.92
BC 472.42
473.08(EX)473.01
TC 473.14
BC 472.64
472.55
TC 472.92
BC 472.42
472.33
DRIVEWAY TYPE C3 PER
COR STANDARD PLAN 104
SEE DETAIL
C303
6
BC 473.02(EX)
473.57(EX)
473.50(EX)
473.56 TC 473.46(EX)
2.
0
%
1.
5
%
4.0%
3.5%
1.
5
%
1.
5
%
3.1
%
2.8
%
1.6%
473
7.
9
'
STOP BAR
SEE DETAIL
C302
6
ASPHALT PAVING
(ARTERIAL STREET SECTION)
SEE DETAIL
C303
8
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
PROTECT EX STUDENT
DROP OFF / PICK UP
SIGN AND POST
CONCRETE
CURB (TYP)
7.4%
7.4%
TC 473.54
BC 473.04
TC 473.03
BC 472.53
TC 472.64 (EX)
BC 472.16 (EX)
TC 472.95 (EX)
BC 472.46 (EX)
1.1%
1.
7
%
RELOCATED
STOP SIGN
23+00
N.E. 10TH ST.
HO
Q
U
I
A
M
A
V
E
.
N
.
E
.
PARALLEL CURB
RAMP
SEE DETAIL
C301
8
ASPHALT PAVING
(ARTERIAL STREET SECTION)
SEE DETAIL
C303
8
NEW THERMOPLASTIC
CROSSWALK STRIPING
PER COR STANDARD
PLAN 127 SEE DETAIL
C302
6
6" CONCRETE
VERTICAL CURB
BC 472.81 (EX)
473.29(EX)
TC 472.95
BC 472.45
TC 472.86
BC 472.36
472.40(EX)
472.32
472.42
0.8
%
0.8%
0.5%
0.8%
1
.
7
%
5
.
9
'
1.
7
%
TC 473.26 (EX)
1
1
'
4.
9
'
1
2
.
7
'
6.
3
'
2.
0
%
0
.
8
%
7
.
8
%
6.
6
%
BC 471.98 (EX)
TC 472.44 (EX)
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DETAILED ROW IMPROVEMENTS
Hoquiam Ave NE Driveway #2 3Scale: 1"=5'
NE 10th St Driveway 1Scale: 1"=5'
Hoquiam Ave NE Driveway #1 2Scale: 1"=5'
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
STOP BAR
SEE DETAIL
C302
6
T-432607
East Ramp on Corner of Hoquiam AVE NE & NE 10th ST 4Scale: 1"=5'
TR
O
-
4
1
-
4
3
2
6
T.
East Ramp on Corner of Hoquiam AVE NE & NE 10th ST 4Scale: 1"=5'
T-432609
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432643
TE
D
-
4
0
-
4
3
2
6
HOQUIAM AVE. N.E.
12'45'5'
455.04(EX)
459.39(EX)
458.32
TC 458.91
BC 458.41
TC 456.76
BC 456.26
DRIVEWAY TYPE C3 PER
COR STANDARD PLAN 104
SEE DETAIL
C303
6
TC 458.86 (EX)
BC 458.36 (EX)TC 459.97 (EX)
BC 459.47 (EX)
455.84
8.0%
6.9%
1.
5
%
1.
2
%
1.
0
%
6.9%
45
7
45
8
45
9
15
'458
459
457
CONNECT TO EX
STORM 8" IE 454.85
PROTECT EX
ATHLETIC FIELDS
SIGN AND POST
CONCRETE
CURB (TYP)
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
ASPHALT PAVING
(ARTERIAL STREET SECTION)
SEE DETAIL
C303
8
TRUNCATED DOMES
SEE DETAIL
C301
12
STOP BAR
SEE DETAIL
C302
6
PROTECT EX STOP
SIGN AND POST
PROTECT EX SCHOOL
SPEED LIMIT 20
SIGN AND POST
PROTECT EX SOLAR
POWERED FLASHER
AND POST
SD E1 CB TYPE I
RIM 457.50
IE 454.85 8"SD(NE)
PROTECT EX
STREET NAME
SIGN AND POST
1.
7
%
6.6%
455.51
TC 456.41
BC 455.91
455.57
9.3'
45
5
45
6
454.80(EX)TC 459.29 (EX)
BC 458.81 (EX)
32+50
E E
HOQUIAM AVE. N.E.
7'4'40'7.4'
469.33(EX)
TC 469.59
BC 469.09
469.00
BC 469.63
BC 469.53
469.47 469.54
BC 469.60470.06(EX)
469.54
DRIVEWAY TYPE C3 PER
COR STANDARD PLAN 104
SEE DETAIL
C303
6
1.
5
%
1.
0
%
1.
0
%
0.
1
%
7.6%
7.4%
469.96(EX)469.88(EX)
6'
TC 469.91 (EX)
BC 469.41 (EX)
TC 469.54 (EX)
BC 469.04 (EX)
4.2%
3.2%
1.
5
%
1.
5
%
469
5.
7
'
47
0
PROTECT EX DO
NOT ENTER SIGN
AND POST
CONCRETE
CURB (TYP)
ASPHALT PAVING
(ARTERIAL STREET SECTION)
SEE DETAIL
C303
8
NEW THERMOPLASTIC
CROSSWALK STRIPING
PER COR STANDARD
PLAN 127 SEE DETAIL
C302
6
TC 470.06 (EX)
BC 469.63 (EX)
TC 469.24 (EX)
BC 468.76 (EX)
1.7%
1.7%
469.81(EX)
28+00
XX
E E E E E E E E E E
SD
SD
SD
SD
SD
SD
E
E
E E E E E E E E E E E E E E E
4
6
9
467
467
468.08
467.74466.62
467.28
4.
3
'
18'8'6'
467.31 468.73
8.0%
1.
5
%
8.0%
TC 468.65
BC 468.15
468.01
1.
5
%
467.21
TC 467.23
BC 466.73
0.5%
1.
5
%
0.5%
1.
5
%
1.5'
N.E. 10TH ST.
SEE SHEET C205
FOR PROPOSED
STORM SYSTEM
INFORMATION
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
ASPHALT PAVING
(RESIDENTIAL
STREET SECTION)
SEE DETAIL (TYP)
C303
8
DRIVEWAY TYPE C3 PER
COR STANDARD PLAN 104
SEE DETAIL
C303
6
TYPE 13 GUARDRAIL PER
WSDOT STD PLAN C20.10-09
SEE DETAIL
C304
2
4.
1
%
7.
7
%
GRADE BREAK
469
46
7
468
46
6
466
4
6
9
46
8
470
471
469.62(EX)
BC 469.12 (EX)
TC 469.57 (EX)
467.67
467.74
6+00
6+50
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DETAILED ROW IMPROVEMENTS
Hoquiam Ave NE Driveway #3 1Scale: 1"=5'
Hoquiam Ave NE Driveway #4 2Scale: 1"=5'
NE 10th St Track and Field Driveway 3Scale: 1"=5'
STOP BAR
SEE DETAIL
C302
6
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
ASPHALT PAVING
(RESIDENTIAL STREET SECTION)
SEE DETAIL
C303
8
T-432608
TR
O
-
4
1
-
4
3
2
6
T-432610
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432644
TE
D
-
4
0
-
4
3
2
6
N.E. 10TH ST.
HO
Q
U
I
A
M
A
V
E
.
N
.
E
.
6'
12
.
9
'
PARALLEL CURB
RAMP
SEE DETAIL
C301
8
472.87(EX)
473.38
472.39
16
'
7.8'
7.0%
5.1%
6" CONCRETE
VERTICAL CURB
6.7
%
472.48
5.1
%
473
NEW THERMOPLASTIC
CROSSWALK STRIPING
PER COR STANDARD
PLAN 127 SEE DETAIL
C302
6
ASPHALT PAVING
(ARTERIAL STREET SECTION)
SEE DETAIL
C303
8
1.5%
1
.
8
%
1.
2
%
0.
5
%
1.9
%
4.0
'
1.5
%
473.47(EX)473.66(EX)
2.9%
TC 473.01
BC 472.51
TC 472.95
BC 472.45
BC 472.90 (EX)
TC 473.28 (EX)
15
'
BC 472.28 (EX)
TC 472.79 (EX)
E E E
E
E
E
E
E
E
HO
Q
U
I
A
M
AV
E
.
N
.
E
.
469.72
469.58
8.2
'
469.91
470.83(EX)470.89(EX)
N.E. 11TH CT
470.02
TC 470.22
BC 469.72
TC 470.13
BC 469.63
ASPHALT PAVING
(ARTERIAL STREET SECTION)
SEE DETAIL
C303
8
PERPENDICULAR
CURB RAMP
SEE DETAIL
C302
9
NEW THERMOPLASTIC
CROSSWALK STRIPING
PER COR STANDARD
PLAN 127 SEE DETAIL
C302
6
CONCRETE CURB AND
GUTTER AND ASPHALT
PAVING (ARTERIAL
STREET SECTION)
SEE DETAIL
C303
8
TC 470.11
0.0
%
0.
9
%
1.7%
1.6
%
4.6%
1.2%
8.5
'
4.5
%
12
.
6
'
8.
0
%
7.
9
%
1
.
5
%
BC 469.95
7.8'
3.2%
TC 469.83
BC 469.33
469.87(EX)
10
.
8
'
470.73
470.66
1.6%
BC 470.22 (EX)
TC 470.71 (EX)
BC 469.20 (EX)
TC 469.62 (EX)
TC 470.57
BC 470.07
4.
8
%
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
DETAILED ROW IMPROVEMENTS
T-432609Not Used 11NTS
Not Used 10NTS
Not Used 9NTS
Not Used 8NTS
Not Used 4NTS
Corner of NE 10TH & Hoquiam Ave NE 1Scale: 1"=5'
Corner of NE 11TH CT & Hoquiam Ave NE 2Scale: 1"=5'
TR
O
-
4
1
-
4
3
2
6
T-432611
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432645
TE
D
-
4
0
-
4
3
2
6
NE 10TH ST SECTION A
SCALE: 1" = 10'
440
450
460
470
480
440
450
460
470
480
PR
O
P
E
R
T
Y
L
I
N
E
PROPOSED
STREET LIGHT
(BEYOND)
PROPOSED
TREE (BEYOND)
EX 12" STORM
(RECORD)
EX 8" SEWER
(RECORD)
EX GRADE
(TYP)
FINISHED
GRADE (TYP)
EX 2" GAS
EX 4" GAS
PROPOSED
ELECTRICAL
N.
E
.
1
0
T
H
S
T
.
CE
N
T
E
R
L
I
N
E
CONCRETE SIDEWALK
SEE DETAIL
C303
7
CURB AND GUTTER
SEE DETAIL
C303
8
NE 10TH ST SECTION B
SCALE: 1" = 10'
440
450
460
470
480
490
440
450
460
470
480
490PROPOSED
STREET LIGHT
(BEYOND)
EX 2" GAS
EX 4" GAS
EX 8" WATER
EX 12" STORM
(RECORD)
N.
E
.
1
0
T
H
S
T
.
CE
N
T
E
R
L
I
N
E
EX 8" SEWER
(RECORD)
PROPOSED
TREE (BEYOND)
FINISHED
GRADE (TYP)
PROPOSED
ELECTRICAL
CONCRETE SIDEWALK
SEE DETAIL
C303
7
CURB AND GUTTER
SEE DETAIL
C303
8
EX 8" STORM
NE 10TH ST SECTION C
SCALE: 1" = 10'
440
450
460
470
480
440
450
460
470
480
PR
O
P
E
R
T
Y
L
I
N
E
N.
E
.
1
0
T
H
S
T
.
CE
N
T
E
R
L
I
N
E
EX 2" GAS
EX 4" GAS
EX 8"
WATER
EX 12" STORM
(RECORD)
EX 8" SEWER
(RECORD)
PROPOSED
ELECTRICAL
HEAVY DUTY
ASPHALT PAVING
SEE DETAIL
C300
7
DRIVEWAY TYPE C3
PER COR STANDARD
PLAN 104 SEE DETAIL
C303
6
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
ROW SECTIONS
T-432610Not Used 9NTS
Not Used 8NTS
Not Used 7NTS
Not Used 6NTS
Not Used 5NTS
Not Used 3NTS
Section A 1Scale: 1"=10'
Section B 2Scale: 1"=10'
Section C 4Scale: 1"=10'
TR
O
-
4
1
-
4
3
2
6
T-432612
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432646
TE
D
-
4
0
-
4
3
2
6
N.E. 10TH ST.
( A DEDICATED PUBLIC RIGHT OF WAY)
E
E
E E E E E E
E SUBSD
SD
E
EE
E
E E E E E E E E E E E E E
SDSDSDSDSDSDSDSDSD
47
04
6
9
471
467
467
4
5
5 460 465456457458459461462463464 466
3+00 4+00 5+00 6+00 7+00 8+00
3+50 4+50 5+50 6+50 7+50 8+50
MA
T
C
H
L
I
N
E
8
+
5
0
NE 10TH ST
Scale: 1"=5' V. 1"=20' H
445
450
455
460
465
470
475
480
485
490
445
450
455
460
465
470
475
480
485
490
4+00 5+00 6+00 7+00 8+00
PROPOSED BACK
OF WALK (TYP)
PROPOSED TOP
OF CURB (TYP)
PROPOSED
FLOWLINE (TYP)
EX CL GRADE
PROPOSED BACK
OF WALK (TYP)
PROPOSED TOP
OF CURB (TYP)
PROPOSED
FLOWLINE (TYP)
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
NE 10TH ST PROFILE
T-432611
TR
O
-
4
1
-
4
3
2
6
SCALE 1"=20'
0 10 20 40
T-432613
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432647
TE
D
-
4
0
-
4
3
2
6
N.E. 10TH ST.
( A DEDICATED PUBLIC RIGHT OF WAY)
( A DEDICATED PUBLIC RIGHT OF WAY)
47
6
47
6
475
473
9+00 10+00 11+00 12+00 13+00
8+50 9+50 10+50 11+50 12+50 13+5020
+
0
0
20
+
5
0
MA
T
C
H
L
I
N
E
8
+
5
0
NE 10TH ST
Scale: 1"=5' V. 1"=20' H
445
450
455
460
465
470
475
480
485
490
445
450
455
460
465
470
475
480
485
490
PROPOSED BACK
OF WALK (TYP)
PROPOSED TOP
OF CURB (TYP)
PROPOSED
FLOWLINE (TYP)
EX CL GRADE
9+00 10+00 11+00 12+00 13+00
CITY OF
RENTON
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
43667
NSTATE O F WASHI
N
G
T
ON
R
EGIST E R E D
P
R
O
F
E
SSIONAL E N G IN EER
O
S
B
O
CAJA.DLAREJ
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
HAZEN HIGH SCHOOL MODERNIZATION
NE 10TH ST PROFILE
T-432612
TR
O
-
4
1
-
4
3
2
6
SCALE 1"=20'
0 10 20 40
T-432614
DEVELOPMENT ENGINEERING
msippo 08/07/2025
R-432648
TE
D
-
4
0
-
4
3
2
6
E E
E
E EE
SS
GT
GT
GT
GTGT
GT
GT
GT
E
E
E
E
E
E
E
E
GT
GT
GT
GTGT
GT
GT
GT
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
EE
E
E
E
EEE
E
E
E
E
E E E
E
EE
E
E
E
E
E
E
E
E E
E
EE
E
E
E EEE
E
EEEEEEEE
E
E
E
E
E
E E E E
SD
SD
SD
SD
SDSDSD
45
7
46
0
46
0
45
8
45
9
45
9
468
4
6
9
46
5
466
4
6
2
46
3
470
471
47
7
477
477
468
469
470
46
5461
46
2
46
3
464
46
6
467
468
469
468.10
468.11
468.11468.11
468.13
468.13
470.43 (EX)
470.62 (EX)470.29 (EX)
470.48 (EX)470.34 (EX)
470.23 (EX)
470.39 (EX)
470.38 (EX)
470.94 (EX)
470.34 (EX)
470.67 (EX)
470.61 (EX)
470.66 (EX)470.67 (EX)
470.64 (EX)
470.67 (EX)
470.46 (EX)
470.52 (EX)
467.72
468.07 467.99 (EX)467.95 (EX)467.92 (EX)
467.82 (EX)
467.72 (EX)
467.66 (EX)467.63 (EX)
467.59 (EX)
467.55 (EX)
467.41 (EX)467.97467.91
467.41 467.40
470.54 (EX)
457.64 (EX)
457.40 (EX)
457.54 (EX)456.89 (EX)
456.66 (EX)
456.31 (EX)
456.51 (EX)
456.55 (EX)
457.49 (EX)
457.42 (EX)
456.98 (EX)
456.86 (EX)
455.39 (EX)
455.88 (EX)
470.78
470.69(EX)470.57 (EX)
470.71 (EX)
470.56 (EX)
470.76 (EX)
470.66 (EX)
470.85 (EX)
470.86 (EX)
470.80 (EX)470.87 (EX)
471.67 (EX)
471.65 (EX)
471.18 (EX)471.17 (EX)
467.94 (EX)
467.94 (EX)
467.84 (EX)
467.89 (EX)
467.56 (EX)
467.51 (EX)467.43 (EX)467.46 (EX)
467.47 (EX)
467.54 (EX)
467.54 (EX)467.95 (EX)468.02 (EX)
469.29 (EX)
469.40 (EX)
469.77 (EX)
457.95(EX)
458.24(EX)
459.12(EX)
459.42(EX)
459.71(EX)
461.04(EX)
456.48(EX)
456.55(EX)
458.00(EX)
460.68(EX)
460.83(EX)
460.80(EX)
460.58(EX)
460.46(EX)
459.94(EX)
458.39(EX)
476.97(EX)
477.00(EX)
477.00(EX)
476.96(EX)
476.98
476.96
476.94
477.01(EX)476.99(EX)
476.93(EX)
470.65
470.95 (EX)
470.77 (EX)
470.73 (EX)
470.64 (EX)
470.52
470.66
470.43 (EX)
470.67
470.58 (EX)
470.75(EX)
470.84(EX)
470.79 (EX)470.76 (EX)470.77 (EX)
1.8
%
3.3
%
1.8
%
1.8
%
0.3%0.3%1.0
%
0.1
%
0.2%
0.4%
1.8
%
1.8
%
1.8
%
1.8
%
1.8
%
1.5
%
C300
9
X
X
X
X
X
X
X
X
X
X
X
E1
0
2
1
E1
0
3
1
E5
0
2
1 E5
0
2
1
E1
0
3
5
E1
0
2
3
E1
0
2
2
L103
L102
L101
L104
L105
L104
EE
E
EE
E
E
E
E
E
E E
E
E
E
E
E
E
E
EE
E
45
9
457.95(EX)
458.24(EX)
459.12(EX)
459.42(EX)
L102
GENERAL NOTES:
SITE IMPROVEMENTS LEGEND
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
0 26
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T E CT
OVERALL LANDSCAPE PLAN & LEGEND
1" = 60'
R-432649
N
R-432649
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
E
E
E
E E E E E E E
E
E E E E
GTGTGTGT
GT
GT
GT
GT
GT
GT
GT
GT
G
T
GT
GT
GT
GT
GT
GT
GT
GT
GT GT GT GT
EEE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EEE
E
E
E
E
E
E
E
E
GTGTGTGT
GT
GT
GT
GT
GT
GT
GT
GT
G
T
GT
GT
GT
GT
GT
GT
GT
GT
GT GT GT GT GT GTGTGT
E
E
E
E
E
E
E
E
EEEE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
EEEEEEEE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
45
7
46
0
46
0
45
8
45
9
457.64 (EX)
457.40 (EX)
456.66 (EX)
456.31 (EX)
456.51 (EX)
456.55 (EX)
457.49 (EX)
457.42 (EX)
456.98 (EX)
456.86 (EX)
455.39 (EX)
455.88 (EX)
457.95(EX)459.42(EX)
459.71(EX)
461.04(EX)
456.48(EX)
456.55(EX)
458.00(EX)
460.68(EX)
460.83(EX)
460.80(EX)
460.58(EX)
460.46(EX)
459.94(EX)
458.39(EX)
XX
X
X
X
X X
X
X
XXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
BASEBALL FIELD
MATCHLINE - SEE SHEET L102
MATCHLINE - SEE SHEET L101
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
0 26
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T ECT
LANDSCAPE PLAN
1" = 20'
R-432650
N
R-432650
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
45
9
457.64 (EX)
457.40 (EX)
457.54 (EX)456.89 (EX)
456.98 (EX)
456.86 (EX)
457.95(EX)
458.24(EX)
459.12(EX)
459.42(EX)
X
MATCHLINE - SEE SHEET L102
MATCHLINE - SEE SHEET L101
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
026
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T E CT
LANDSCAPE PLAN
1" = 20'
R-432651
N
R-432651
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
E
E
E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
EEEEE
EEEEE
EEEE
E E E E
E EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
EEEEEEEEEEEEEE
SD
SD
SD
SDSDSDSDSDSDSDSDSD
4
6
9
46
5
466
4
6
2
4
6
3
470
471
477
477
46
546
1
46
2
46
3
46
4
46
6
46
7
468
469
476.97(EX)
477.00(EX)
477.00(EX)
476.96(EX)
476.98
476.99(EX)
X
X
E1
0
3
1
FASTPITCH
FIELD
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
L
1
0
3
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
L
1
0
4
FASTPITCH
NE 10TH ST
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
026
ST A T E
SHIN
L
A
N
D
S
CAP
NI
A S A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T E CT
LANDSCAPE PLAN
1" = 20'
R-432652
N
R-432652
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
E
E
E
EEE
E
EEEEEEE
EEE
47
7
477
476.96
476.94
477.01(EX)
476.93(EX)
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
L
1
0
3
MA
T
C
H
L
I
N
E
-
S
E
E
S
H
E
E
T
L
1
0
4
FASTPITCH
FIELD
NE 10TH ST
HO
Q
U
I
A
M
A
V
E
N
E
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
026
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T E CT
LANDSCAPE PLAN
1" = 20'
R-432653
N
R-432653
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
W
E
E E E E
E
E
E
E E E E
E
470.43 (EX)
470.62 (EX)
470.29 (EX)
470.48 (EX)470.34 (EX)
470.23 (EX)
470.39 (EX)
470.38 (EX)
470.94 (EX)
470.34 (EX)
470.67 (EX)
470.61 (EX)
470.66 (EX)470.67 (EX)
470.64 (EX)
470.67 (EX)
470.46 (EX)
470.52 (EX)
470.54 (EX)
470.78
470.69(EX)470.57 (EX)
470.71 (EX)
470.56 (EX)
470.76 (EX)
470.66 (EX)
470.85 (EX)
470.86 (EX)
470.80 (EX)470.87 (EX)
471.67 (EX)
471.65 (EX)
471.18 (EX)471.17 (EX)
470.65
470.95 (EX)
470.77 (EX)
470.73 (EX)
470.64 (EX)
470.52
470.66
470.43 (EX)
470.67
470.58 (EX)
470.75(EX)
470.84(EX)
470.79 (EX)470.76 (EX)470.77 (EX)
1.
8
%
3.
3
%
1.
8
%
1.
8
%
0.3%0.3%1.
0
%
0.
1
%
0.2%
0.4%
1.
8
%
1.
8
%
1.
8
%
1.
8
%
1.
8
%
1.
5
%
C300
9
E1
0
2
3
SITE IMPROVEMENTS LEGEND GATE SCHEDULE
SYMBOL QTY BOTANICAL / COMMON NAME SIZE CONDITION / REMARKS
DECIDUOUS TREES
12 GINKGO BILOBA 'PNI 2720'
PRINCETON SENTRY® MAIDENHAIR TREE MIN. 2" CAL., 8`-10` HT.B&B, WELL BRANCHED ABOVE 6` HT.
SYMBOL QTY BOTANICAL / COMMON NAME SIZE CONDITION/REMARKS
GROUND COVERS
16 CISTUS X HYBRIDUS
WHITE ROCKROSE MIN. 1 GAL. CONTAINER 36" O.C. TRIANG. SPAC.
LAWN
110,010 SF LAWN SEE SPECIFICATION
PLANT SCHEDULE
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
0 26
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T ECT
LANDSCAPE PLAN & LEGEND
1" = 20'
R-432654
N
R-432654
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
X
X
X
X
X
X
X
X
X
X
X
E E
E
E EE
SS
GT
GT
GT
GTGT
GT
GT
GT
E
E
E
E
E
E
E
E
GT
GT
GT
GTGT
GT
GT
GT
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
EE
E
E
E
EEE
E
E
E
E
E E E
E
EE
E
E
E
E
E E
E
E E
E
EE
E
E
E EEE
E
E EEEEEEE
E
E
E
E
E
E E E E
SD
SD
SD
SD
SDSDSD
45
7
46
0
46
0
45
8
45
9
45
9
468
4
6
9465466463464
470
471
468
469
470
47
7
477
477
465464
466
467 468
469
468.10
468.11
468.11468.11
468.13
468.13
470.43 (EX)
470.62 (EX)470.29 (EX)
470.48 (EX)470.34 (EX)
470.23 (EX)
470.39 (EX)
470.38 (EX)
470.94 (EX)
470.34 (EX)
470.67 (EX)
470.61 (EX)
470.66 (EX)470.67 (EX)
470.64 (EX)
470.67 (EX)
470.46 (EX)
470.52 (EX)
467.72
468.07 467.99 (EX)467.95 (EX)467.92 (EX)
467.82 (EX)
467.72 (EX)
467.66 (EX)467.63 (EX)
467.59 (EX)
467.55 (EX)
467.41 (EX)467.97467.91
467.41 467.40
470.54 (EX)
457.64 (EX)
457.40 (EX)
457.54 (EX)456.89 (EX)
456.66 (EX)
456.31 (EX)
456.51 (EX)
456.55 (EX)
457.49 (EX)
457.42 (EX)
456.98 (EX)
456.86 (EX)
455.39 (EX)
455.88 (EX)
470.78
470.69(EX)470.57 (EX)
470.71 (EX)
470.56 (EX)
470.76 (EX)
470.66 (EX)
470.85 (EX)
470.86 (EX)
470.80 (EX)470.87 (EX)
471.67 (EX)
471.65 (EX)
471.18 (EX)471.17 (EX)
467.94 (EX)
467.94 (EX)
467.84 (EX)
467.89 (EX)
467.56 (EX)
467.51 (EX)467.43 (EX)
467.46 (EX)
467.47 (EX)
467.54 (EX)
467.54 (EX)467.95 (EX)
468.02 (EX)
469.29 (EX)
469.40 (EX)
469.77 (EX)
457.95(EX)
458.24(EX)
459.12(EX)
459.42(EX)
459.71(EX)
461.04(EX)
456.48(EX)
456.55(EX)
458.00(EX)
460.68(EX)
460.83(EX)
460.80(EX)
460.58(EX)
460.46(EX)
459.94(EX)
458.39(EX)
476.97(EX)
477.00(EX)
477.00(EX)
476.96(EX)
476.98
476.96
476.94
477.01(EX)476.99(EX)
476.93(EX)
470.65
470.95 (EX)
470.77 (EX)
470.73 (EX)
470.64 (EX)
470.52
470.66
470.43 (EX)
470.67
470.58 (EX)
470.75(EX)
470.84(EX)
470.79 (EX)
470.76 (EX)470.77 (EX)
1.8
%
3.3
%
1.8
%
1.8
%
0.3%0.3%1.0
%
0.1
%
0.2%
0.4%
1.8
%
1.8
%
1.8
%
1.8
%
1.8
%
1.5
%
C300
9
E1
0
2
1
E1
0
3
1
E5
0
2
1 E5
0
2
1
E1
0
3
5
E1
0
2
3
E1
0
2
2
L303
L302
L301
TTTT
T T T T
S
E
EE
E
E
E
E
E E
E
E
E
E
E
E
E
E
45
9
458.24(EX)
459.12(EX)
L302
IRRIGATION NOTES FOR
CONNECTING TO EXISTING SYSTEM:
IRRIGATION NOTES FOR
NEW SYSTEM:
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
026
ST A T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T E CT
OVERALL IRRIGATION PLAN
1" = 60'
R-432655
N
R-432655
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
X
X
X
X
X X
X
X
XXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
E
E E E E E E E
E
E E E E
GTGTGTGT
GT
GT
GT
GT
GT
GT
GT
GT
G
T
GT
GT
GT
GT
GT
GT
GT
GT
GT GT GT GT
EEE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EEE
E
E
E
E
E
E
E
E
GTGTGTGT
GT
GT
GT
GT
GT
GT
GT
GT
G
T
GT
GT
GT
GT
GT
GT
GT
GT
GT GT GT GT GTGT
E
E
E
E
EEEE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
EEEEE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E E E E E E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
EEE
E
E
E
E
E
E
E
E
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
45
7
46
0
46
0
45
8
45
9
45
9
457.64 (EX)
457.40 (EX)
457.54 (EX)456.89 (EX)
456.66 (EX)
456.31 (EX)
456.51 (EX)
456.55 (EX)
457.49 (EX)
457.42 (EX)
456.98 (EX)
456.86 (EX)
455.39 (EX)
455.88 (EX)
457.95(EX)459.42(EX)
459.71(EX)
461.04(EX)
456.48(EX)
456.55(EX)
458.00(EX)
460.68(EX)
460.83(EX)
460.80(EX)
460.58(EX)
460.46(EX)
459.94(EX)
458.39(EX)
BASEBALL FIELD
MATCHLINE - SEE SHEET L302
MATCHLINE - SEE SHEET L301
S
POINT OF CONNECTION
CONTROLLER
WIRELESS RAIN SENSOR
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
0 26
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7/2
O F W A
G
T
O
N
E A R C H I T E CT
IRRIGATION PLAN
1" = 20'
R-432656
N
R-432656
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
45
9
458.24(EX)
459.12(EX)
MATCHLINE - SEE SHEET L302
MATCHLINE - SEE SHEET L301
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
026
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T ECT
IRRIGATION PLAN & DETAILS
1" = 20'
R-432657
N
QUICK COUPLER BOX1
HALF COMBOX
NOTES:
1.SPORTFIELD SPECIALTIES HALF COMBOX (CBIT1815HD) WITH INFILL RETAINER SYSTEM FOR SYNTHETIC TURF
APPLICATIONS. INSTALL PER MFR.'S RECOMMENDATIONS.
2
R-432657
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
E
E
E
E
EEE
E
EEEEEEEEEE
EEEEEE
EEEE
E E E E
E EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
SD
SD
470
471
47
7
477
477
476.97(EX)
477.00(EX)
477.00(EX)
476.96(EX)
476.98
476.96
476.94
477.01(EX)476.99(EX)
476.93(EX)
FASTPITCH
FIELD
L303
NE 10TH ST
MA
T
C
H
L
I
N
E
-
SE
E
T
H
I
S
S
H
E
E
T
X
X
E
E
E E E E E E
E
E
E
E E E E E E E E E E E E E
SD
SD
SDSDSDSDSDSDSDSDSD
4
6
9465466463464
470
471
46
546
4
46
6
46
7
468
469
TTTT
T T T T
NE 10TH ST MA
T
C
H
L
I
N
E
-
SE
E
T
H
I
S
S
H
E
E
T
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
0 26
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T E CT
IRRIGATION PLAN
1" = 20'
R-432658
N
R-432658
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI DETAIL
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI GPM RADIUS DETAIL
IRRIGATION SCHEDULE 1
NUMBER MODEL SIZE TYPE GPM DESIGN PSI PRECIP
VALVE SCHEDULE 1
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY DETAIL
S
T
IRRIGATION SCHEDULE 1
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
0 26
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T ECT
IRRIGATION SCHEDULE & DETAILS
1" = 20'
R-432659
POINT OF CONNECTION - WITH DOUBLE CHECK VALVE1
R-432659
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
460.68(EX)
460.83(EX)
460.80(EX)
S
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
026
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T E CT
IRRIGATION DETAILS
1" = 20'
MANUAL DRAIN VALVE3
QUICK COUPLER VALVE4 REMOTE CONTROL VALVE - WITH SHUT-OFF6
R-432660
POC PLAN ENLARGEMENT1 IRRIGATION CONTROLLER (EXTERIOR PEDESTAL)2
FLOW SENSOR5 R-432660
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
026
ST A T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T E CT
IRRIGATION DETAILS
1" = 20'
LARGE ROTOR IRRIGATION HEAD1 TEMPORARY TREE IRRIGATION3
R-432661
PIPE TRENCHING AND BACKFILL4
IRRIGATION HEAD2
ISOLATION / SHUT-OFF VALVE5 RAIN SENSOR6 R-432661
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
SYNTHETIC TURF EDGE ANCHOR AT BASEBALL/SOFTBALL3
SYNTHETIC TURF EDGE ANCHOR AT EXISTING PAVING4 SYNTHETIC TURF
ABOVE STORM SYSTEM ABOVE SUBGRADE
5
ARCHITECTUREINTEGRUS&YGHOF COLLABORATIONA
Job No.:
Drawn By:
Checked by:
Date:
1 1 7 S O U T H M A I N S T R E E T , S U I T E 1 0 0 , S E A T T L E , W A . 9 8 1 0 4 T E L E P H O N E : ( 2 0 6 ) 6 2 8 - 3 1 3 7 F A X : ( 2 0 6 ) 6 2 8 - 3 1 3 8
22318.00
AM, AJ, IL, TY
NH
06.16.25
RE
N
T
O
N
S
C
H
O
O
L
D
I
S
T
R
I
C
T
11
0
1
H
O
Q
U
I
A
M
A
V
E
N
E
R
E
N
T
O
N
,
W
A
9
8
0
5
9
CONFORMED SET
HA
Z
E
N
H
I
G
H
S
C
H
O
O
L
M
O
D
E
R
N
I
Z
A
T
I
O
N
Revisions
#Date Description
1430 NE 65th StreetSeattle, WA 98115t: 206-322-1732fora.landFora Landscape ArchitectsCHOLPHGAN.75 EXP 4 0 26STATESHINLANDSCAPNIASANO3./1 7 /2OFWA GTONEARCHITECT
4'-6' HT. CHAIN LINK FENCE1
DOUBLE SWING CHAIN LINK GATE2
L400
LANDSCAPE
DETAILS
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
0 26
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T ECT
N/A
LANDSCAPE DETAILS
R-432662
300
OUTFIELD SIGN6 R-432662
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
ARCHITECTUREINTEGRUS&YGHOF COLLABORATIONA
Job No.:
Drawn By:
Checked by:
Date:
1 1 7 S O U T H M A I N S T R E E T , S U I T E 1 0 0 , S E A T T L E , W A . 9 8 1 0 4 T E L E P H O N E : ( 2 0 6 ) 6 2 8 - 3 1 3 7 F A X : ( 2 0 6 ) 6 2 8 - 3 1 3 8
22318.00
AM, AJ, IL, TY
NH
06.16.25
RE
N
T
O
N
S
C
H
O
O
L
D
I
S
T
R
I
C
T
11
0
1
H
O
Q
U
I
A
M
A
V
E
N
E
R
E
N
T
O
N
,
W
A
9
8
0
5
9
CONFORMED SET
HA
Z
E
N
H
I
G
H
S
C
H
O
O
L
M
O
D
E
R
N
I
Z
A
T
I
O
N
Revisions
#Date Description
1430 NE 65th StreetSeattle, WA 98115t: 206-322-1732fora.landFora Landscape ArchitectsCHOLPHGAN.75 EXP 4 026STATESHINLANDSCAPNIASANO3./1 7 /2OFWA GTONEARCHITECT
L401
LANDSCAPE
DETAILS
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
0 26
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S A
N
O
3 ./1 7/2
O F W A
G
T
O
N
E A R C H I T E CT
LANDSCAPE DETAILS
N/A
BASE ANCHOR AT SYNTHETIC TURF1
R-432663
HOME PLATE AT SYNTHETIC TURF2
PITCHERS RUBBER AT SYNTHETIC TURF4
L401
1
L401
1
L401
3
L401
2
BASE LAYOUT3
FOUL POLE5 R-432663
DEVELOPMENT ENGINEERING
msippo 08/07/2025
amorganroth
08/08/2025
CURRENT PLANNING
□
□
□
T
E E
E
E EE
SS
GT
GT
GT
GTGT
GT
GT
GT
E
E
E
E
E
E
E
E
GT
GT
GT
GTGT
GT
GT
GT
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
EE
E
E
E
E
EE
E
E
E
E
E E
E
E
EE
E
E
EE
E
E
E E
E
E
E E
E
E
E
EE
E
E
E EEE
E
E EEEEEEE
E
E
E
E
E
E E E E
SD
SD
SD
SD
SDSDSD
5'
PAINTED "WHITE"
PEDESTRIAN
PATHWAY STRIPING
SEE DETAIL
8'
PAINTED "WHITE"
CROSSWALK STRIPING
SEE DETAIL
8.7
'
2'1.5'
45
7
46
0
46
0
45
8
45
9
45
9
468
46
9
465 466
46
2
46
3
470
471
47
7
477
477
468
469
470
465461
46
2
46
3
464
46
6
46
7 468
469
468.10
468.11
468.11468.11
468.13
468.13
470.43 (EX)
470.62 (EX)470.29 (EX)
470.48 (EX)470.34 (EX)
470.23 (EX)
470.39 (EX)
470.38 (EX)
470.94 (EX)
470.34 (EX)
470.67 (EX)
470.61 (EX)
470.66 (EX)470.67 (EX)
470.64 (EX)
470.67 (EX)
470.46 (EX)470.52 (EX)
467.72
468.07 467.99 (EX)467.95 (EX)467.92 (EX)
467.82 (EX)
467.72 (EX)
467.66 (EX)467.63 (EX)
467.59 (EX)
467.55 (EX)
467.41 (EX)467.97467.91
467.41 467.40
470.54 (EX)
457.64 (EX)
457.40 (EX)
457.54 (EX)
456.89 (EX)
456.66 (EX)
456.31 (EX)
456.51 (EX)
456.55 (EX)
457.49 (EX)
457.42 (EX)
456.98 (EX)
456.86 (EX)
455.39 (EX)
455.88 (EX)
470.78
470.69(EX)470.57 (EX)
470.71 (EX)
470.56 (EX)
470.76 (EX)
470.66 (EX)
470.85 (EX)
470.86 (EX)
470.80 (EX)470.87 (EX)
471.67 (EX)
471.65 (EX)
471.18 (EX)471.17 (EX)
467.94 (EX)
467.94 (EX)
467.84 (EX)
467.89 (EX)
467.56 (EX)
467.51 (EX)
467.43 (EX)467.46 (EX)
467.47 (EX)
467.54 (EX)
467.54 (EX)467.95 (EX)468.02 (EX)
469.29 (EX)
469.40 (EX)
469.77 (EX)
457.95(EX)
458.24(EX)
459.12(EX)
459.42(EX)
459.71(EX)
461.04(EX)
456.48(EX)
456.55(EX)
458.00(EX)
460.68(EX)
460.83(EX)
460.80(EX)
460.58(EX)
460.46(EX)
459.94(EX)
458.39(EX)
476.97(EX)
477.00(EX)
477.00(EX)
476.96(EX)
476.98
476.96
476.94
477.01(EX)476.99(EX)476.93(EX)
470.65
470.95 (EX)
470.77 (EX)
470.73 (EX)
470.64 (EX)
470.52
470.66
470.43 (EX)
470.67
470.58 (EX)
470.75(EX)
470.84(EX)470.79 (EX)
470.76 (EX)470.77 (EX)1.8
%
3.3
%
1.8
%
1.8
%
0.3%0.3%1.0
%
0.1
%
0.2%
0.4%
1.8
%
1.8
%
1.8
%
1.8
%
1.8
%
1.5
%
C300
9
NE 10TH ST NE 10TH STNE 10TH ST
X
X
X
X
X
X
X
X
X
X
X
E1
0
2
1
E1
0
3
1
E5
0
2
1 E5
0
2
1
E1
0
3
5
E1
0
2
3
E1
0
2
2
HAZEN HIGH
SCHOOL
CO
L502
L501
SUBDRAINAGE NOTES
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
0 26
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T ECT L500
OVERALL
SUBDRAINAGE
PLAN
OVERALL SUBDRAINAGE PLAN
1" = 60'
ARCHITECTUREINTEGRUS&YGHOF COLLABORATIONA
Job No.:
Drawn By:
Checked by:
Date:
1 1 7 S O U T H M A I N S T R E E T , S U I T E 1 0 0 , S E A T T L E , W A . 9 8 1 0 4 T E L E P H O N E : ( 2 0 6 ) 6 2 8 - 3 1 3 7 F A X : ( 2 0 6 ) 6 2 8 - 3 1 3 8
22318.00
AM, AJ, IL, TY
NH
06.16.25
RE
N
T
O
N
S
C
H
O
O
L
D
I
S
T
R
I
C
T
11
0
1
H
O
Q
U
I
A
M
A
V
E
N
E
R
E
N
T
O
N
,
W
A
9
8
0
5
9
CONFORMED SET
HA
Z
E
N
H
I
G
H
S
C
H
O
O
L
M
O
D
E
R
N
I
Z
A
T
I
O
N
Revisions
#Date Description
1430 NE 65th StreetSeattle, WA 98115t: 206-322-1732fora.landFora Landscape ArchitectsCHOLPHGAN.75 EXP 4 0 26STATESHINLANDSCAPNIASANO3./1 7 /2OFWA GTONEARCHITECT
R-432664
N
R-432664
DEVELOPMENT ENGINEERING
msippo 08/07/2025
E
E E E E E E E
E
E E E E
GTGTGTGT
GT
GT
GT
GT
GT
GT
GT
GT
G
T
GT
GT
GT
GT
GT
GT
GT
GT
GT GT GT GT
EEE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EEE
E
E
E
E
E
E
E
E
GTGTGTGT
GT
GT
GT
GT
GT
GT
GT
GT
G
T
GT
GT
GT
GT
GT
GT
GT
GT
GT GT GT GT GTGT
E
E
E
E
EEEEEE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
EEEE
E
E
E
E
E
E
E
E
E
E
E
E
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
45
7
46
0
46
0
45
8
45
9
45
9
457.64 (EX)
457.40 (EX)
457.54 (EX)
456.89 (EX)
456.66 (EX)
456.31 (EX)
456.51 (EX)
456.55 (EX)
457.49 (EX)
457.42 (EX)
456.98 (EX)
456.86 (EX)
455.39 (EX)
455.88 (EX)
457.95(EX)
458.24(EX)
459.12(EX)
459.42(EX)
459.71(EX)
461.04(EX)
456.48(EX)
456.55(EX)
458.00(EX)
460.68(EX)
460.83(EX)
460.80(EX)
460.58(EX)
460.46(EX)
459.94(EX)
458.39(EX)
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CO
5
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
026
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T E CT L501
SUBDRAINAGE PLAN
1" = 20'
ARCHITECTUREINTEGRUS&YGHOF COLLABORATIONA
Job No.:
Drawn By:
Checked by:
Date:
1 1 7 S O U T H M A I N S T R E E T , S U I T E 1 0 0 , S E A T T L E , W A . 9 8 1 0 4 T E L E P H O N E : ( 2 0 6 ) 6 2 8 - 3 1 3 7 F A X : ( 2 0 6 ) 6 2 8 - 3 1 3 8
22318.00
AM, AJ, IL, TY
NH
06.16.25
RE
N
T
O
N
S
C
H
O
O
L
D
I
S
T
R
I
C
T
11
0
1
H
O
Q
U
I
A
M
A
V
E
N
E
R
E
N
T
O
N
,
W
A
9
8
0
5
9
CONFORMED SET
HA
Z
E
N
H
I
G
H
S
C
H
O
O
L
M
O
D
E
R
N
I
Z
A
T
I
O
N
Revisions
#Date Description
1430 NE 65th StreetSeattle, WA 98115t: 206-322-1732fora.landFora Landscape ArchitectsCHOLPHGAN.75 EXP 4 0 26STATESHINLANDSCAPNIASANO3./1 7/2OFWA GTONEARCHITECT
SUBDRAINAGE
PLAN
R-432665
N
R-432665
N
DEVELOPMENT ENGINEERING
msippo 08/07/2025
E
E
E
EEE
E
EEEEEEEEEE
EEEEEE
EEEE
E E E E
E
E
E
E
E
E
E
SD
47
7
477
477
476.97(EX)
477.00(EX)
477.00(EX)
476.96(EX)
476.98
476.96
476.94
477.01(EX)476.99(EX)476.93(EX)
NE 10TH ST
SUBDRAINAGE LEGEND
CO
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
0 26
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T E CT L502
SUBDRAINAGE
PLAN
SUBDRAINAGE PLAN
1" = 20'
ARCHITECTUREINTEGRUS&YGHOF COLLABORATIONA
Job No.:
Drawn By:
Checked by:
Date:
1 1 7 S O U T H M A I N S T R E E T , S U I T E 1 0 0 , S E A T T L E , W A . 9 8 1 0 4 T E L E P H O N E : ( 2 0 6 ) 6 2 8 - 3 1 3 7 F A X : ( 2 0 6 ) 6 2 8 - 3 1 3 8
22318.00
AM, AJ, IL, TY
NH
06.16.25
RE
N
T
O
N
S
C
H
O
O
L
D
I
S
T
R
I
C
T
11
0
1
H
O
Q
U
I
A
M
A
V
E
N
E
R
E
N
T
O
N
,
W
A
9
8
0
5
9
CONFORMED SET
HA
Z
E
N
H
I
G
H
S
C
H
O
O
L
M
O
D
E
R
N
I
Z
A
T
I
O
N
Revisions
#Date Description
1430 NE 65th StreetSeattle, WA 98115t: 206-322-1732fora.landFora Landscape ArchitectsCHOLPHGAN.75 EXP 4 0 26STATESHINLANDSCAPNIASANO3./1 7 /2OFWA GTONEARCHITECT
R-432666
N
R-432666
DEVELOPMENT ENGINEERING
msippo 08/07/2025
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
TE
D
-
4
0
-
4
3
2
6
C2
4
0
0
5
7
7
1
HAZEN HIGH SCHOOL MODERNIZATIONCHOLPH
G
A
N
.75 EXP 4
0 26
STA T E
SHIN
L
A
N
D
S
CAP
NI
A S
A
N
O
3 ./1 7 /2
O F W A
G
T
O
N
E A R C H I T E CT
SUBDRAINAGE DETAILS
1" = 20'
TRACK AND FIELD SUBSURFACE SECTION - NORTH-SOUTH1 MULTI-FLOW SUBDRAIN SECTION2
LATERAL TO COLLECTOR CONNECTION3 TIGHTLINE COLLECTOR SECTION4 CLEANOUT AT BASEBALL FIELD FENCE5
ARCHITECTUREINTEGRUS&YGHOF COLLABORATIONA
Job No.:
Drawn By:
Checked by:
Date:
1 1 7 S O U T H M A I N S T R E E T , S U I T E 1 0 0 , S E A T T L E , W A . 9 8 1 0 4 T E L E P H O N E : ( 2 0 6 ) 6 2 8 - 3 1 3 7 F A X : ( 2 0 6 ) 6 2 8 - 3 1 3 8
22318.00
AM, AJ, IL, TY
NH
06.16.25
RE
N
T
O
N
S
C
H
O
O
L
D
I
S
T
R
I
C
T
11
0
1
H
O
Q
U
I
A
M
A
V
E
N
E
R
E
N
T
O
N
,
W
A
9
8
0
5
9
CONFORMED SET
HA
Z
E
N
H
I
G
H
S
C
H
O
O
L
M
O
D
E
R
N
I
Z
A
T
I
O
N
Revisions
#Date Description
1430 NE 65th StreetSeattle, WA 98115t: 206-322-1732fora.landFora Landscape ArchitectsCHOLPHGAN.75 EXP 4 0 26STATESHINLANDSCAPNIASANO3./1 7 /2OFWA GTONEARCHITECT
L503
SUBDRAINAGE
DETAILS
R-432667
R-432667
DEVELOPMENT ENGINEERING
msippo 08/07/2025
T
J
CLNG
J
J
1
E-001
SECTION IDENTIFIER
REVISION TAG
DETAIL OR DRAWING IDENTIFIER
EQUIPMENT IDENTIFIER
SHEET NOTE
RACEWAY SYMBOLS
REFERENCE SYMBOLS
EXISTING ELECTRICAL WORK
NEW ELECTRICAL WORK
ENLARGED PLAN BORDER
MATCHLINE
ITEM TO BE REMOVED
AREA NOT IN CONTRACT
CONDUIT IN CEILING OR WALL
CONDUIT IN FLOOR OR BELOW GRADE
HOME RUN TO BRANCH CIRCUIT PANELBOARD
4PN-102/1,3,5
DIAGRAM SYMBOLS
POWER SYMBOLS
GF
M
CIRCUIT BREAKER
GROUND FAULT RELAY
METER
TRANSFORMER
GROUND
CURRENT TRANSFORMER
CABLE TRAY - LADDER TYPE
LIGHTING SYMBOLS
JUNCTION BOX
JUNCTION BOX CEILING
JUNCTION BOX FLOOR
TRANSFORMER
SAFETY DISCONNECT SWITCH (FUSED)
PANELBOARD
EQUIPMENT CONNECTION. REFER TO
MOTOR AND EQUIPMENT SCHEDULE FOR
REQUIREMENTS
1
1
E-001
AHU-XXX
E3.1 MATCHLINE ARROW
SPD
TVSS
SURGE PROTECTIVE DEVICE
TRANSIENT VOLTAGE SURGE SUPPRESSOR
TRANSFER SWITCH
FAULT CURRENT TAG
FUSED SWITCH
SINGLE POLE SINGLE THROW SWITCH
FUSE
1
NORTH ARROW
XX.XKAIC
SITE LIGHT POLE
SAFETY DISCONNECT SWITCH (NON-FUSED)
ELECTRICAL SHEET LIST
E001 ELECTRICAL LEGEND
E002 ELECTRICAL ABBREVIATIONS AND NOTES
E101 ELECTRICAL SITE PLAN - STREET LIGHTING N.E. 10TH ST.
E102 ELECTRICAL SITE PLAN - RRFB - HOQUIAM AVE. N.E.
E901 ELECTRICAL DETAILS
E902 ELECTRICAL DETAILS
E903 ELECTRICAL DETAILS
E904 ELECTRICAL DETAILS
E905 ELECTRICAL DETAILS
RECTANGULAR RAPID FLASHING BEACON
ELECTRICAL LEGEND E001
65 OF 73
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
HAZEN HIGH SCHOOL MODERNIZATION
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
TR
O
-
4
1
-
4
3
2
6
T-432608
ELECTRICAL LEGEND
NONE 02.21.2025
E001
65 OF 7368 OF 76
T-432613
07.11.25
T-432615
condition of approval:
electrical plans sheets 68-76 not approved. revised design
change for electrical/lighting/rrfb plans shall be
submitted to city project manager(s) meeting city plan
requirements such as corrected lighting luminaire schedule,
wiring diagram, wiring schedule, foundation calculations
and professional engineer's stamp. see condition regarding
rrfb calculation.
please contact city project manager michael Sippo at
425-430-7298 (msippo@rentonwa.gov) to schedule a meeting
to discuss plan requirements and rrfb design and
configuration.
ABBREVIATIONS:
1P 1 POLE (2P, 3P, 4P, ETC.)
A AMPERE
AC ABOVE COUNTER
ACLG ABOVE CEILING
ADO AUTOMATIC DOOR OPENER
AF AMP FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFI ARC FAULT CIRCUIT INTERRUPTER
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
AMPL AMPLIFIER
ANNUN ANNUNCIATOR
APPROX APPROXIMATELY
AQ-STAT AQUASTAT
ARCH ARCHITECT, ARCHITECTURAL
AS AMP SWITCH
AT AMP TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
BATT BATTERY
BD BOARD
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
C CONDUIT
CAB CABINET
CAT CATALOG
CATV CABLE TELEVISION
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CCT CIRCUIT
CLG CEILING
COMB COMBINATION
CMPR COMPRESSOR
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUATION OR CONTINUOUS
CONTR CONTRACTOR
CONV CONVECTOR
CP CIRCULATING PUMP
CRT CATHODE-RAY TUBE
CT CURRENT TRANSFORMER
CTR CENTER
CU COPPER
DCP DOMESTIC WATER CIRCULATING PUMP
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DPR DAMPER
DS SAFETY DISCONNECT SWITCH
DT DOUBLE THROW
DWG DRAWING
EC ELECTRICAL CONTRACTOR
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
ELU EMERGENCY LIGHTING UNIT
EM EMERGENCY
EMS ENERGY MANAGEMENT SYSTEM
EMT ELECTRICAL METALLIC TUBING
EP ELECTRIC PNEUMATIC
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXH EXHAUST
EXP EXPLOSION PROOF
FA FIRE ALARM
FABP FIRE ALARM BOOSTER POWER
FACP FIRE ALARM CONTROL PANEL
FCU FAN COIL UNIT
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FU FUSE
FUDS FUSED SAFETY DISCONNECT SWITCH
GA GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
G,GFI GROUND FAULT CIRCUIT INTERRUPTER
GFP GROUND FAULT PROTECTOR
GND GROUND
GRS GALVANIZED RIGID STEEL (CONDUIT)
GYP BD GYPSUM BOARD
HOA HANDS-OFF-AUTOMATIC SWITCH
HORIZ HORIZONTAL
HP HORSEPOWER
HPF HIGH POWER FACTOR
HT HEIGHT
HTG HEATING
HTR HEATER
HV HIGH VOLTAGE
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
IC INTERRUPTING CAPACITY
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
I/W INTERLOCK WITH
J-BOX JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT-AMPERE
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LOC LOCATE OR LOCATION
LT LIGHT
LTG LIGHTING
LTNG LIGHTNING
LV LOW VOLTAGE
MAX MAXIMUM
MAG.S MAGNETIC STARTER
M/C MOMENTARY CONTACT
MC MECHANICAL CONTRACTOR
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDC MAIN DISTRIBUTION CENTER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MFS MAIN FUSED DISCONNECT SW
MH MANHOLE
MIC MICROPHONE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MMS MANUAL MOTOR STARTER
MOA MULTIOUTLET ASSEMBLY
MSP MOTOR STARTER PANELBOARD
MSBD MAIN SWITCHBOARD
MT MOUNT
MT.C EMPTY CONDUIT
MTS MANUAL TRANSFER SWITCH
MTR MOTOR, MOTORIZED
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NFDS NON-FUSED SAFETY DISCONNECT SWITCH
NIC NOT IN CONTRACT
NL NIGHT LIGHT
N.O. NORMALLY OPEN
NPF NORMAL POWER FACTOR
NTS NOT TO SCALE
OH OVERHEAD
OL OVERLOADS
PA PUBLIC ADDRESS
PB PULL BOX OR PUSHBUTTON
PE PNEUMATIC ELECTRIC
PED PEDESTAL
PF POWER FACTOR
PH PHASE
PIV POST INDICATING VALVE
PNL PANEL
PP POWER POLE
PR PAIR
PRI PRIMARY
PROJ PROJECTION
PRV POWER ROOF VENTILATOR
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE (CONDUIT)
PWR POWER
QUAN QUANTITY
RCPT RECEPTACLE
REQD REQUIRED
RM ROOM
RSC RIGID STEEL CONDUIT
RTU ROOF TOP UNIT
RRFB RECTANGULAR RAPID FLASHING BEACON
SC SURFACE CONDUIT
SEC SECONDARY
SHT SHEET
SIM SIMILAR
S/N SOLID NEUTRAL
SPEC SPECIFICATION
SPKR SPEAKER
SP SPARE
SR SURFACE RACEWAY
SS STAINLESS STEEL
SSW SELECTOR SWITCH
S/S STOP/START PUSHBUTTONS
STA STATION
STD STANDARD
SURF SURFACE MOUNTED
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TEL TELEPHONE
TEL/DATA TELEPHONE/DATA
TERM TERMINAL
TL TWIST LOCK
TR TAMPER RESISTANT
T-STAT THERMOSTAT
TTC TELEPHONE TERMINAL CABINET
TV TELEVISION
TVTC TELEVISION TERMINAL CABINET
TYP TYPICAL
UC UNDER COUNTER
UE UNDERGROUND ELECTRICAL
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
UT UNDERGROUND TELEPHONE
UTIL UTILITY
UV ULTRAVIOLET
V VOLT
VA VOLT-AMPERES
VDT VIDEO DISPLAY TERMINAL
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W WATT
W/ WITH
WG WIRE GUARD
WH WATER HEATER
W/O WITHOUT
WP WEATHERPROOF
XFMR TRANSFORMER
XFR TRANSFER
∠ ANGLE
@ AT
▲ DELTA
' FEET
" INCHES
# NUMBER
Ø PHASE
C CENTER LINE
P PLATE
ELECTRICAL GENERAL NOTES:
GENERAL:
1.COORDINATE ELECTRICAL WORK WITH MECHANICAL,
ARCHITECTURAL, STRUCTURAL, CIVIL AND LANDSCAPE
WORK SHOWN ON OTHER CONTRACT DOCUMENTS.
PROVIDE ADDITIONAL OFFSETS FOR COORDINATED
INSTALLATION WHERE REQUIRED.
2.FIELD COORDINATE FINAL MECHANICAL AND EQUIPMENT
LOCATIONS ALONG WITH CONNECTION REQUIREMENTS
AND CONTROL WIRING PRIOR TO ROUGH-IN.
3.CONTRACTOR IS RESPONSIBLE FOR PROVIDE ALL LINE
VOLTAGE CIRCUITING AND CONNECTIONS TO
MECHANICAL EQUIPMENT, PACKAGED UNITS, CONTROL
PANELS, MOTOR STARTERS, MOTOR CONTROLLERS,
VARIABLE FREQUENCY DRIVES AND SIMILAR EQUIPMENT.
COORDINATE ADDITIONAL REQUIREMENTS WITH
CONTROLS CONTRACTOR.
4.COORDINATE EQUIPMENT CONNECTIONS WITH
MANUFACTURERS' CERTIFIED DRAWINGS.
5.COORDINATE ELECTRICAL, COMMUNICATIONS, AND
ELECTRONIC SAFETY AND SECURITY WORK PRIOR TO
INSTALLATION. EQUIPMENT ACCESS TAKES PRECEDENCE
OVER CONDUIT FOR AVAILABLE SPACE.
6.WHERE USED, THE TERM “PROVIDE” SHALL MEAN
“FURNISH AND INSTALL”.
7.PROVIDE CONDUCTORS OPERATING AT 50 VOLTS OR
GREATER IN RACEWAY. PROVIDE METAL RACEWAY
WITHIN THE STRUCTURE ABOVE THE FLOOR SLAB.
PROVIDE PVC RACEWAY BELOW THE FLOOR SLAB AND
UNDERGROUND RACEWAY OUTSIDE THE STRUCTURE.
8.CONDUIT AND WIRE IS NOT PERMITTED TO BE INSTALLED
BELOW FLOOR SLAB UNLESS INDICATED ON PLAN BY
DASHED CONDUIT.
9.LEAVE THE SITE CLEAN AND READY FOR OCCUPANCY.
REMOVE DIRT, DEBRIS, EMPTY CARTONS, TOOLS,
CONDUIT AND WIRE SCRAPS AND MISCELLANEOUS
SPARE EQUIPMENT AND MATERIALS USED IN THIS
DIVISION OF THE WORK DURING CONSTRUCTION.
COMPONENTS SHALL BE FREE OF DUST, GRIT AND
FOREIGN MATERIALS AND LEFT AS NEW BEFORE FINAL
ACCEPTANCE OF WORK.
10.PERFORM WORK TO COMPLY WITH THE STANDARD
PRACTICES FOR GOOD WORKMANSHIP PUBLISHED BY
NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION
(NECA). COMPLY WITH THE LATEST ENFORCED EDITION
OF THE NATIONAL ELECTRICAL CODE (NEC), LOCAL
CODES, AMENDMENTS, AND ORDINANCES.
11.PERFORM ELECTRICAL WORK UNDER THE SUPERVISION
OF A LICENSED MASTER ELECTRICIAN. PROCURE
PERMITS AND LICENSES AND PAY FEES ASSOCIATED
WITH THIS WORK.
12.CONTRACTOR IS RESPONSIBLE FOR SUBMITTING ALL
DOCUMENTATION REQUIRED TO CITY OF RENTON FOR
PERMITTING. COORDINATE WITH ENGINEER FOR ANY
ADDITIONAL DOCUMENTATION.
13.PROVIDE NEW, COMMERCIAL GRADE MATERIALS
FURNISHED FOR THIS PROJECT THAT ARE FREE OF
DEFECTS, AND LISTED BY A NATIONALLY RECOGNIZED
TESTING LABORATORY UNO.
14.CONTRACTOR IS RESPONSIBLE FOR WIRING ELECTRICAL
ITEMS SHOWN ON DRAWINGS.
15.PROVIDE 4" MINIMUM CONCRETE BASES (HOUSEKEEPING
PADS) UNDER FLOOR MOUNTED ELECTRICAL
EQUIPMENT. THIS INCLUDES, BUT IS NOT LIMITED TO
SWITCHBOARDS, GENERATORS, TRANSFORMERS, AND
MOTOR CONTROL CENTERS. COMPLY WITH
REQUIREMENTS FOR EQUIPMENT BASES AND
FOUNDATIONS SPECIFIED IN DIVISION 03.
16.COORDINATE ATTACHMENTS TO STRUCTURE TO VERIFY
THAT ATTACHMENT POINTS ON EQUIPMENT AND
STRUCTURE CAN ACCEPT SEISMIC, WEIGHT, AND OTHER
LOADS IMPOSED.
17.MAINTAIN INDICATED FIRE AND SMOKE RATING OF
WALLS, PARTITIONS, CEILINGS, AND FLOORS AT
ELECTRICAL PENETRATIONS. SEAL PENETRATIONS WITH
FIRESTOP MATERIAL. PROVIDE MATERIAL IN
ACCORDANCE WITH ASTM E 814 AND UL 1479 3M OR
APPROVED. COMPLY WITH REQUIREMENTS SPECIFIED IN
DIVISION 07.
18.PROVIDE FIREBLOCKING AND DRAFT STOPPING AT
ELECTRICAL PENETRATIONS IN COMBUSTIBLE
CONCEALED SPACES PER THE INTERNATIONAL BUILDING
CODE.
19.REFER TO TYPICAL DETAILS PROVIDED IN THIS DRAWING
SET FOR EQUIPMENT INSTALLATION. CONTRACTOR IS
RESPONSIBLE FOR CONFORMANCE WITH DETAILS.
20.LOCATIONS AND SIZES OF FLOOR, WALL, AND ROOF
OPENINGS SHALL BE COORDINATED WITH OTHER
TRADES INVOLVED. INCLUDE IN THE COST OF
ELECTRICAL WORK, CUTTING, CORING, PATCHING AND
PAINTING OF EXISTING WALLS, CEILINGS, FLOORS AND
ROOFS AS REQUIRED TO ACCOMMODATE WORK AS
INDICATED IN THE ELECTRICAL CONTRACT DOCUMENTS,
UNLESS SPECIFICALLY SHOWN ON ARCHITECTURAL
DRAWINGS.
21.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
SAFEKEEPING OF THEIR OWN PROPERTY ON THE JOB
SITE. OWNER ASSUMES NO RESPONSIBILITY FOR
PROTECTION OF PROPERTIES AGAINST FIRE, THEFT AND
ENVIRONMENTAL CONDITIONS.
22.CLEAN THE JOB SITE DAILY AND REMOVE FROM THE
PREMISES ANY DIRT AND DEBRIS CAUSE BY THE
PERFORMANCE OF THE WORK INCLUDED IN THIS
CONTRACT. BEFORE SUBSTANTIAL COMPLETION, CLEAN
EQUIPMENT, FIXTURES, EXPOSED CONDUIT AND SIMILAR
ITEMS.
23.PROVIDE EQUIPMENT THAT FITS INTO THE SPACE
ALLOTTED AND ALLOWS ADEQUATE ACCEPTABLE
CLEARANCE FOR INSTALLATION, REPLACEMENT, ENTRY,
SERVICING AND MAINTENANCE. COORDINATE WITH
OTHER TRADES TO ENSURE NO CONFLICT WITH
REQUIRED CLEARANCES.
24.BUILDING SPACE IS LIMITED. STRONG ATTENTION TO
DETAIL AND CARE MUST BE TAKEN WHEN DEVELOPING
SHOP DRAWING SO ROUTING IS COORDINATED WITH
OTHER DISCIPLINES.
25.MATERIALS WITHIN PLENUMS SHALL BE
NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD
INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED
INDEX OF NOT MORE THAN 50 WHEN TESTED IN
ACCORDANCE WITH ASTM E 84 OR UL 723.
EXISTING ELECTRICAL:
1.WORK SHALL BE PERFORMED IN A CLEAN AND
WORKMANLIKE MANNER. CARE SHALL BE EXERCISED TO
MINIMIZE ANY INCONVENIENCE OR DISTURBANCE TO
OTHER AREAS OF THE BUILDING WHICH ARE TO REMAIN
IN OPERATION. ISOLATE WORK AREAS BY MEANS OF
TEMPORARY PARTITIONS AND/OR TARPS TO KEEP DUST
AND DIRT WITHIN THE CONSTRUCTION AREA.
2.EXISTING MATERIALS THAT ARE REMOVED SHALL NOT BE
REUSED IN NEW SYSTEMS, EXCEPT WHERE INDICATED
AS BEING RELOCATED.
3.WHERE INDICATED, CONDUIT OR PORTIONS OF CONDUIT
SHALL BE REUSED. REFER TO DRAWING PLANS FOR
POINTS OF CONNECTIONS.
4.PROVIDE TEMPORARY SUPPORT OF EXISTING
ELECTRICAL SYSTEMS WHERE REQUIRED BY
DEMOLITION OR ALTERATION OF EXISTING STRUCTURE
DURING CONSTRUCTION. COORDINATE WITH GENERAL
CONTRACTOR AND PROVIDE ALL NECESSARY CONDUIT
AND EQUIPMENT SUPPORTS AND HANGERS TO MAINTAIN
INTEGRITY, SAFETY AND PROPER OPERATION OF
EXISTING ELECTRICAL SYSTEMS FOR THE DURATION OF
THE WORK.
DEMOLITION:
1.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
COORDINATE DEMOLITION/INSTALLATION OF ELECTRICAL
SYSTEMS AND THOSE REQUIRING ELECTRICAL
CONNECTIONS TO MAINTAIN NEC REQUIRED
CLEARANCES, INCLUDED BY NOT LIMITED TO AREAS
ABOVE ACCESSIBLE CEILINGS.
2.COORDINATE WITH OTHER TRADES FOR PROPER
DEMOLITION OF EQUIPMENT. CONSULT THE DRAWINGS
OF OTHER TRADES OR CRAFTS TO AVOID CONFLICTS
WITH EQUIPMENT, ETC. RESOLVE CONFLICTS PRIOR TO
ROUGH-IN AND AT NO ADDITIONAL COST TO THE OWNER.
3.TAKE CAUTION IN DEMOLITION OF ELECTRICAL
EQUIPMENT.
4.CONTRACTOR SHALL REMOVE AND LEGALLY DISPOSE OF
ALL CONDUIT AND EQUIPMENT INDICATED ON DRAWINGS
INCLUDING ALL ASSOCIATED HANGERS, WIREMOLD,
WIRING, DEVICES, CONTROLS, AND APPURTENANCES
ASSOCIATED WITH EACH PIECE OF EQUIPMENT.
5.EXISTING CONTROL PATHWAYS MAY BE RE-USED.
COORDINATE CONTROLS DEMO WORK PRIOR TO
DEMOLITION.
6.WHERE EXISTING ITEMS PENETRATE A WALL OR ROOF,
CONTRACTOR SHALL PROVIDE INFILL AT (E)
PENETRATIONS THROUGH WALL/ROOF WITH LIKE
MATERIALS. PATCH & REPAIR TO MATCH SURROUNDING
SURFACES INCLUDING PAINT.
7.CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT OF
EXISTING ELECTRICAL EQUIPMENT WHERE REQUIRED BY
DEMOLITION OR ALTERATION OF EXISTING STRUCTURE
DURING CONSTRUCTION. COORDINATE WITH GC AND
PROVIDE NECESSARY SUPPORTS AND HANGERS TO
MAINTAIN INTEGRITY, SAFETY AND PROPER OPERATION
OF EXISTING ELECTRICAL SYSTEMS.
8.THE OWNER HAS THE RIGHT TO RETAIN OWNERSHIP OF
ANY MATERIALS BEING REMOVED. DELIVER ITEMS TO
THE OWNER'S REPRESENTATIVE AS INDICATED IN THE
CONTRACT DOCUMENTS. NOTIFY OWNER IN WRITING AT
LEAST 7 DAYS IN ADVANCE OF DEMOLITION.
ELECTRICAL ABBREVIATIONS
AND NOTES
E002
66 OF 73
T-434302
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
HAZEN HIGH SCHOOL MODERNIZATION
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
TR
O
-
4
1
-
4
3
2
6
T-432609
ELECTRICAL ABBREVIATIONS AND
NOTES
NONE 02.21.2025
E002
66 OF 7369 OF 76
T-432614
07.11.25
T-432616
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
HAZEN HIGH SCHOOL MODERNIZATION
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
TR
O
-
4
1
-
4
3
2
6
~ASPH~
6'AW
6'AW6'AW
8"W(R)8"W(R)
IE 8"PVC(W):463.70'IE 8"PVC(E):461.36'
8"PSD
12"PSD
12"PSD(R)
B RIM:452.87'
12"PE(S):449.35'
O:449.35' BTM:447.9'
12"PSD(R)
8"SS
8"PSS
8"PSS(R)
8"PSS(R)
8"PSS(R)
2"G(P)
2"G(P)
2"G(P)
4"G(R)
4"G(R)
SLHH
N.E. 10TH ST.
( A DEDICATED PUBLIC RIGHT OF WAY)
30'
T-432610
ELECTRICAL SITE PLAN - STREET LIGHTING
N.E. 10TH ST.E101
67 OF 73
1"=10'02.21.2025
N.E. 10TH ST.
( A DEDICATED PUBLIC RIGHT OF WAY)
2
~ASPH~
6'AW
6'AW6'AW
8"W(R)8"W(R)
IE 8"PVC(W):463.70'IE 8"PVC(E):461.36'
8"PSD
12"PSD
12"PSD(R)
RIM:452.87'
"PE(S):449.35'
449.35' BTM:447.9'
12"PSD(R)
8"SS
8"PSS
8"PSS(R)
8"PSS(R)
8"PSS(R)
2"G(P)
2"G(P)
2"G(P)
4"G(R)
4"G(R)
SLHH
N.E. 10TH ST.
( A DEDICATED PUBLIC RIGHT OF WAY)
30'
N.E. 10TH ST.
( A DEDICATED PUBLIC RIGHT OF WAY)
2
70 OF 76
T-432615
NE TH ST
A DEDICATED P8%LIC RI*HT OF WAY
4
2
4
4
4
3
3
3
3
3
NE TH ST
A DEDICATED P8%LIC RI*HT OF WAY
4
2
4
4
4
3
3
3
3
3
INSTALL LIGHT POLE FOUNDATION, POLE, POLE ARM, AND
LUMINAIRE IN ACCORDANCE WITH MANUFACTURER
RECOMMENDATIONS AND RENTON PUBLIC WORKS DETAILS 117.2,
117.3, 119 ON SHEET E906.
SCALE 1"=20'
1 21 31 1
07.11.25
NE TH ST
A DEDICATED P8%LIC RI*HT OF WAY
4
2
4
4
4
3
3
3
3
3
TM2 TM3 TM4
TM6
TM
OFFSITE LIGHTING LUMINAIRE SCHEDULE
LUM. POLE ID
SL1
STREET NAME
N.E 10TH ST.DOMA PENDANT CY55P1B LED SERIES
MODEL STATION
DOME STYLE LED PEDESTRIAN LUMINAIRE
DESCRIPTION
FIXED
BASE TYPE
0.850
LFF
Q524
LUMENS
55.1
-ATTAGE
SL2 DOME STYLE LED PEDESTRIAN LUMINAIREFIXED 0.850 Q524 55.1
SL3 DOME STYLE LED PEDESTRIAN LUMINAIREFIXED 0.850 Q524 55.1
SL4 DOME STYLE LED PEDESTRIAN LUMINAIREFIXED 0.850 Q524 55.1
SL5 DOME STYLE LED PEDESTRIAN LUMINAIREFIXED 0.850 Q524 55.1
N.E 10TH ST.
N.E 10TH ST.
N.E 10TH ST.
N.E 10TH ST.
DOMA PENDANT CY55P1B LED SERIES
DOMA PENDANT CY55P1B LED SERIES
DOMA PENDANT CY55P1B LED SERIES
DOMA PENDANT CY55P1B LED SERIES
OFFSET MOUNTING HEIGHT ARM LENGTHMANUFACTURER
CYCLONE LIGHTING
CYCLONE LIGHTING
CYCLONE LIGHTING
CYCLONE LIGHTING
CYCLONE LIGHTING
240
VOLTAGE
240
240
240
240
4K60W
4K60W
4K60W
4K60W
4K60W
1QK6QW
1QK6QW
1QK6QW
1QK6QW
1QK6QW
3,Q1.Q9 23.00K LT
4,27.3Q 23.00K LT
23.00K LT
23.00K LT
23.00K LT
4,99.8Q
5,Q8.87
Q,42.5Q
1. EQUIPMENT AND CONDUIT ROUTING SHOWN IS DIAGRAMMATIC.
COORDINATE EQUIPMENT LOCATION WITH ARCHITECTURAL,
STRUCTURAL, CIVIL, AND LANDSCAPE PRIOR TO INSTALLATION.
2. PROVIDE RIGID STEEL SWEEPS FOR ALL UNDERGROUND CONDUIT.
3. PROVIDE HANDHOLES AS REQUIRED FOR ALL POWER AND LIGHTING
CIRCUITS. SPLICE CONDUCTORS IN HANDHOLES.
4. PROVIDE ADDITIONAL PULL BOXES AS REQUIRED TO MINIMIZE TOTAL
BEND RADIUS TO 270 DEGREES FOR POWER CONDUCTORS AND 180
DEGREES FOR LOW VOLTAGE CABLING. SIZE PULL BOXES PER NEC.
5. COORDINATE WITH UTILITY COMPANIES FOR CONNECTING SERVICES.
GENERAL NOTES:
1 REMOVE EXISTING STREET LIGHT FIXTURE. INTERCEPT CONDUIT
PATHWAY IN EXISTING HAND HOLE FOR NEW STREET LIGHTING.
INSTALL LIGHT POLE FOUNDATION, POLE, POLE ARM, AND
LUMINAIRE IN ACCORDANCE WITH MANUFACTURER
RECOMMENDATIONS AND RENTON PUBLIC WORKS DETAILS 117.1,
117.3, 119 ON SHEET E906.
PROVIDE OLDCASTLE TYPE 1 JUNCTION BOX WITH NON-SKID LID.
SEE CITY OF RENTON STANDARD DETAIL 119 ON SHEET E906 FOR
ADDITIONAL INFORMATION.
PROVIDE (1) 2"C, 2#8, 1#8 EGC.
FLAG NOTES:
1
2
3
4
INSTALL LIGHT POLE FOUNDATION, POLE, POLE ARM, AND
LUMINAIRE IN ACCORDANCE WITH MANUFACTURER
RECOMMENDATIONS AND RENTON PUBLIC WORKS DETAILS 117.2,
117.3, 119 ON SHEET E906.
SCALE 1"=20'
1 21 31 1
SCALE 1"=10'
5 10 200
NE TH ST
A DEDICATED P8%LIC RI*HT OF WAY
4
2
4
4
4
3
3
3
3
3
TM2 TM3
TM4
TM6TM
T-432617
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
HAZEN HIGH SCHOOL MODERNIZATION
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
TR
O
-
4
1
-
4
3
2
6
E102
68 OF 73
1"=10'
STOP BAR
6'CW
W(P)
W(P)
W(P)
W(P)
Tcd(P)
CB RIM:469.93'
IE 10"PE(S):468.15'
H2O LEVEL:468.20'
BTM:466.50'
18"PSD
SOLID LID CB RIM:469.51'
IE 12"IP(N):466.80'
IE 12"IP(S):466.90'
H2O:466.70' BTM:465.3'
SOLID LID CB RIM:469.45'
IE 12"IP(N):467.15'
IE 12"IP(S):467.20'
H2O:467.05' BTM:465.6'
SOLID LID CB RIM:471.73'
IE 12"IP(N):468.35'
IE 12"IP(S):468.5'
H2O:468.35' BTM:467.1'
12"PSD
CB RIM:468.95'
IE 18"CP(N):466.05'
IE 18"CP(S):466.20'
BTM:465.95'
OHP&T
OHP&T
ICB
2"G(P)
4"G(R)
G(P)
PP
ELEC. CABINET
SLHH
CD
Ecd(P)
Ctv(P)
HOQUIAM AVE. N.E.
(A DEDICATED PUBLIC RIGHT OF WAY)
N.E. 11TH CT.
30'
FOUND M.I.C.
PUNCHED
2" BRASS
DISC IN
CONC,
DOWN 0.50'
12"DEC
2"DEC
2"
D
E
C
5",6"DEC
ELECTRONIC READER BOARD
FOG STRIPE
FOG STRIPE
DYS
DYS
STOP BAR
"HAZEN HIGH
SCHOOL"
"PEDESTRIAN CROSSING"
18"C
R
W
LSCAPE
6"CC & 12"CG
6"CC & 12"CG
CC&CG
CC&CG
CC&CG
5'CW
5'CW
5'CW
FLEXIBLE
DELINEATOR
(TYPICAL)
BLACK/YELLOW CAUTION DELINEATOR
~ASPH~
~ASPH~
~ASPH~
5
2
5
3
8
3
2
6
1
4
(E) SERVICE CABINET
(E) ELECTRICAL PATHWAY
(E) STREET LIGHTING HAND HOLE
1. EQUIPMENT AND CONDUIT ROUTING SHOWN IS DIAGRAMMATIC.
COORDINATE EQUIPMENT LOCATION WITH ARCHITECTURAL,
STRUCTURAL, CIVIL, AND LANDSCAPE PRIOR TO INSTALLATION.
2. PROVIDE RIGID STEEL SWEEPS FOR ALL UNDERGROUND CONDUIT.
3. PROVIDE HANDHOLES AS REQUIRED FOR ALL POWER AND LIGHTING
CIRCUITS. SPLICE CONDUCTORS IN HANDHOLES.
4. PROVIDE ADDITIONAL PULL BOXES AS REQUIRED TO MINIMIZE TOTAL
BEND RADIUS TO 270 DEGREES FOR POWER CONDUCTORS AND 180
DEGREES FOR LOW VOLTAGE CABLING. SIZE PULL BOXES PER NEC.
5. COORDINATE WITH UTILITY COMPANIES FOR CONNECTING SERVICES.
GENERAL NOTES:
1 PROVIDE NEW POWER CONDUCTORS FOR NEW RRFB TO
CONTACTORS IN EXISTING SERVICE CABINET.
FURNISH AND INSTALL NEW TYPE II JUNCTION BOX.
PROVDE (1) 2" SCHEDULE 80 PVC CONDUIT WITH 5C CABLE FROM
HAND HOLE TO FLASHING BEACON POLE. SEE SECTION 1330.05(7)(A)
OF WSDOT DESIGN MANUAL M 22-01.23 FOR ADDITIONAL
INFORMATION.
PROVDE (1) 2" SCHEDULE 80 PVC CONDUIT WITH 5C CABLE AND (1)
2" SCHEDULE 80 PVC CONDUIT SPARE. SEE SECTION 1330.05(7)(A)OF
WSDOT DESIGN MANUAL M 22-01.23 FOR ADDITIONAL INFORMATION.
CONSTRUCT FOUNDATION PER WSDOT STANDARD PLAN J-20.15-04,
SHEET TS-05. FURNISH AND INSTALL 15' FB SIGNAL POLE PER CITY
OF RENTON STANDARD PLANS 141.1 AND 141.2 LOCATED ON SHEET
E906 WITH TWO 36"X36" W11-2 SIGNS, ONE 30"X18" W16-7P(R) SIGN,
ONE 30"X18" W16-7P(L) SIGN, TWO RRFB UNITS, ONE 12"X12" R11-501
SIGN AND ONE APS PEDESTRIAN PUSHBUTTON ON THE SIGNAL
POLE. RRFB LIGHT BARS SHALL BE MODEL SC315-G, BY CARMANAH
OR APPROVED EQUAL. SEE CROSSWALK RRFB POLE DETAILS ON
SHEET E906 FOR CONFIGURATION OF SIGNS AND BEACONS. NEW
APS PEDESTRIAN PUSHBUTTON SHALL FACE EAST, PARALLEL TO
CROSSWALK.
INTERCEPT AND EXTEND EXISTING CONDUIT AND CONDUCTORS TO
NEW JUNCTION BOX.
FLAG NOTES:
1
2
3
4
5
6
T-432611
ELECTRICAL SITE PLAN - RRFB
HOQUIAM AVE. N.E.
T-432611
02.21.2025
HO
4
8
I
A
M
A
9
E
N
E
A
D
E
D
I
C
A
T
E
D
P
8
%
L
I
C
R
I
*
H
T
O
F
W
A
Y
7
8
9
8
7
21
6
9
(E) SERVICE CABINET
(E) ELECTRICAL PATHWAY
(E) STREET LIGHTING HAND HOLE
HO
4
8
I
A
M
A
9
E
N
E
A
D
E
D
I
C
A
T
E
D
P
8
%
L
I
C
R
I
*
H
T
O
F
W
A
Y
( T(S9,D( D$C,O(U
( (M(DUS,D$M 3$UI:$Z
( TUS((U M,HIU,OH I$OE IPM(
HO
4
8
I
A
M
A
9
E
N
E
A
D
E
D
I
C
A
T
E
D
P
8
%
L
I
C
R
I
*
H
T
O
F
W
A
Y
3
2
3
4
4
6
6
7
(TUS((U M,HIU,OH I$OE IPM(
(T(S9,D( D$C,O(U
((M(DUS,D$M 3$UI:$Z
71 OF 76
T-432616
SCALE 1"=20'
1 21 31 1
NE TH CT
07.11.25
HO
4
8
I
A
M
A
9
E
N
E
A
D
E
D
I
C
A
T
E
D
P
8
%
L
I
C
R
I
*
H
T
O
F
W
A
Y
3
2
3
4
4
6 6
7
(TUS((U M,HIU,OH I$OE IPM(
(T(S9,D( D$C,O(U
((M(DUS,D$M 3$UI:$Z
CONSTRUCT RRFB POLE PER CITY OF RENTON STANDARD PLANS
141.1 THROUGH 141.5. FURNISH AND INSTALL 15' FB SIGNAL POLE
PER CITY OF RENTON STANDARD PLANS 141.1 AND 141.2 LOCATED
ON SHEET E906 WITH TWO 36"X36" W11-2 SIGNS, ONE 30"X18"
W16-7P(R) SIGN, ONE 30"X18" W16-7P(L) SIGN, TWO RRFB UNITS,
ONE 12"X12" R11-501 SIGN AND ONE APS PEDESTRIAN PUSHBUTTON
ON THE SIGNAL POLE. RRFB LIGHT BARS SHALL BE MODEL SC315-G,
BY CARMANAH OR APPROVED EQUAL. SEE CROSSWALK RRFB POLE
DETAILS ON SHEET E906 FOR CONFIGURATION OF SIGNS AND
BEACONS. NEW APS PEDESTRIAN PUSHBUTTON SHALL FACE EAST,
PARALLEL TO CROSSWALK.
HO
4
8
I
A
M
A
9
E
N
E
A
D
E
D
I
C
A
T
E
D
P
8
%
L
I
C
R
I
*
H
T
O
F
W
A
Y
3
2
3
4
4
6 6
7
(TUS((U M,HIU,OH I$OE IPM(
(T(S9,D( D$C,O(U
((M(DUS,D$M 3$UI:$Z
SCALE 1" = 10'SCALE 1"=20'
1 21 31 1
SCALE 1"=10'
5 10 200
T-432618
as a condition of approval the applicant
shall provide a blow-up detail of the ped push
button that demonstrates compliance with
prowag standards for review and approval
condition of approval:
RRFB crossing shall be coordinated with city project review
managers post-permit issuance and be designed and
constructed in a manner that is satisfactory to city
development engineering and transportation operations
group. design shall incorporate necessary safety elements
including, but not limited to, photometric analysis of
crosswalk meeting city standards, protected islands to
reduce crossing distance, clear sight lines of beacons, ADA
requirements, and independent north/south and east/west
crossings.
TRANSPORTATION OPERATION
cbarnes 08/07/2025
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
HAZEN HIGH SCHOOL MODERNIZATION
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
TR
O
-
4
1
-
4
3
2
6
E901
69 OF 73
1"=10'
T-432612
ELECTRICAL DETAILS
NONE 02.21.2025
72 OF 76
T-432617
07.11.25
T-432619
TRANSPORTATION OPERATION
cbarnes 08/07/2025
condition of approval:
streetlight foundation design analysis to be
submitted and approved prior to installation
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
HAZEN HIGH SCHOOL MODERNIZATION
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
TR
O
-
4
1
-
4
3
2
6
E902
70 OF 73
1"=10'
T-432613
ELECTRICAL DETAILS
NONE 02.21.2025
73 OF 76
T-432618
07.11.25
T-432620
TRANSPORTATION OPERATION
cbarnes 08/07/2025
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
HAZEN HIGH SCHOOL MODERNIZATION
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
TR
O
-
4
1
-
4
3
2
6
E903
71 OF 73
1"=10'
T-432614
ELECTRICAL DETAILS
NONE 02.21.2025
74 OF 76
T-432619
07.11.25
T-432621
TRANSPORTATION OPERATION
cbarnes 08/07/2025
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
HAZEN HIGH SCHOOL MODERNIZATION
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
TR
O
-
4
1
-
4
3
2
6
E904
72 OF 73
1"=10'
T-432615
ELECTRICAL DETAILS
NONE 02.21.2025
75 OF 76
T-432620
07.11.25
T-432622
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
HAZEN HIGH SCHOOL MODERNIZATION
C2
4
0
0
2
7
7
1
LU
A
2
4
-
0
0
0
3
4
9
PR
2
4
-
0
0
0
0
7
8
TR
O
-
4
1
-
4
3
2
6
E905
73 OF 73
1"=10'
T-432616
ELECTRICAL DETAILS
NONE 02.21.2025
76 OF 76
T-432621
DWG NAME: J013 SP PAGE: J013
07.11.25
T-432623
TRANSPORTATION OPERATION
cbarnes 08/07/2025