Loading...
HomeMy WebLinkAboutR-432634E N co i NJ- 0 CINCH ANCHOR WIRE ROPE CLIP (SS) DEFORMED %" STEEL ROD (SS OR ALUMINUM) LENGTH TO FIT PVC PIPE & CROSS RIM 455.09 LEVELING BRICK OR CONCRETE COLLAR AS NECESSARY 2' 0 5' FLOW CONTROL STRUCTURE OVERFLOW ELEVATION 453.00 — — — — — — — DETAIL A: PIPE SUPPORT DETAIL 1/2"SUPPORT RECTANGULAR WEIR 451.70 (2 MIN.) SEE DETAIL'A' FLOW CONTROL 4 1/2" CONTROL DEVICE ORIFICE 3 ASSEMBLY TO BE STRUCTURE IE 450.70 RIM 476.84 REMOVABLE FROM NON -SHRINK GROUT INSIDE THE FCS 0.75" = 3/4" SEE DETAIL'D' 1'-0" MAX ORIFICE 2 PVC PIPE STUB SHEAR GATE IE 449.40 SHIELDED SEE DETAIL'C' 0.875" = 7/8" DIET SEE D 2� COUPLING INVERT 0.5' GASKET (TYP) o 12" RISER OVERFLOW ELEVATION 474.00 -- — — — — — — 12" RISER PIPE 1/4" PIPE PVC ADAPTER W/ DOUBLE RECTANGULAR WEIR 473.05 SUPPORT (2 MIN.) GASKET AND ADHESIVE �' SEE DETAIL'A' BONDED SAND FINISH ON ORIFICE PLATE EXTERIOR, MIN 7" LONG ORIFICE 1 DIAMETER* ORIFICE 2 IE 471.98 CAULK SPACE BETWEEN PVC PIPE CROSS 0.5" = 1/2" PVC ADAPTER AND PIPE STUB SEE DETAIL'D' 12" SDINLET 12" SD OUTLET DETAIL B: CONNECTION & 12" SD INLET 12" SD OUTLET IE 470.36 IE 470.36 CONTROL DEVICE IE 444.00 IE 444.00 NOTES: 1. PVC PIPE MUST BE SCHEDULE 40, PER ASTM 1785. 2. *CONSTRUCTION DRAWINGS MUST PROVIDE ELEVATION AND DIAMETER FOR TYPE 2 N CATCH BASIN SUPPORT (2 MIN.) TYPE 2 CATCH BASIN N SUPPORT (2 MIN.) SEE DETAIL'A' ORIFICE 1 AND ORIFICE 2 AND DIMENSIONS AND ELEVATION FOR THE SEE DETAIL'A' BOTTOM OF THE V-NOTCH WEIR AND ELEVATION FOR OVERFLOW. 3. FIELD CHANGES TO DETENTION PIPE INVERT AND SLOPE REQUIRE SEE DETAILS 3 5 SEE DETAILS 3 5 ORIFICE 1 CONFIRMATION FROM THE ENGINEER OF RECORD THAT THE CONSTRUCTION cs1 c310 cs1 c310 N IE 468.36 DRAWING ELEVATIONS FOR THE FLOW CONTROL DEVICE ASSEMBLY STILL N ORIFICE 1 54" 0.875"= 7/8" MEET THE DESIGN REQUIREMENTS. IE 442.00 SEE DETAIL'B' 54" 1" SEE DETAIL'B' 77 o NEOPRENE REFERENCE CITY OF RENTON CONTROL REFERENCE CITY OF RENTON CONTROL GASKET LIFT GATE AND PIPE STRUCTURE DETAIL FOR ADDITIONAL INFORMATION STRUCTURE DETAIL FOR ADDITIONAL INFORMATION SEE DETAIL S/SHEET C310 SEE DETAIL S/SHEET C310 C LIFT GATE i CONTROL ROD N/ELDED GATE ASSEMBLY TO PIPE \ 12" SD 12" SD SD INLET N INLET OUTLET DETAIL C: LIFT GATE ASSEMBLY � ELBOW STAND PIPE WALL I STUB WELDED TO STAND PIPE IE PER PLANS 12" SD OUTLET ORIFICE PLATE WELDED 6" BAND ELBOW WITH REMOVABLE TO STUB ORIFICE WATER TIGHT COUPLING DETAIL D: SECONDARY ORIFICE SD Al CONTROL STRUCTURE SD C1 CONTROL STRUCTURE - - NTS Scale:1"=2' Scale: 1'L2' NTS A '�F Control Structure Details Control Structure Al (Baseball Field) Control Structure C1 (Softball Field) Not Used R-432634 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING t rIL msippo 08/07/2025 {� A• e/ A SURVEYED: sue: HORIZONTAL: N D 1983/1991 N/A CITY �� HAZEN HIGH SCHOOL MODERNIZATION �o7.1 1.2025 W DESIGNED:JAJ FlELDBOOK: DRAWN: RENTON PAGE: DJD/AJJ ONE INCH DATUM DRAWING NO: NTS �E�iS-F0L ° s �, CHECKED: JAJ AT FULL s�LE Planning/Building/Public IF NOT DNE INCH Works De t. p DRAINAGE DETAILS C3 1 3 Not Used C S,�N�L v� N0. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY SHEET: OF: 05 29 20 5 JAJ I 1 1 34 OF 7 T O N A, u NJ - CM O O i N Q J O O N cc ,@I