HomeMy WebLinkAboutR-432634E
N
co
i
NJ-
0
CINCH ANCHOR
WIRE ROPE CLIP (SS)
DEFORMED %" STEEL ROD (SS
OR ALUMINUM) LENGTH TO FIT
PVC PIPE & CROSS
RIM 455.09
LEVELING BRICK OR
CONCRETE COLLAR
AS NECESSARY
2'
0 5'
FLOW CONTROL STRUCTURE
OVERFLOW ELEVATION 453.00 — — — — — — —
DETAIL A: PIPE SUPPORT DETAIL
1/2"SUPPORT
RECTANGULAR WEIR 451.70
(2 MIN.)
SEE DETAIL'A'
FLOW CONTROL 4 1/2" CONTROL DEVICE
ORIFICE 3
ASSEMBLY TO BE
STRUCTURE
IE 450.70
RIM 476.84
REMOVABLE FROM
NON -SHRINK GROUT INSIDE THE FCS
0.75" = 3/4"
SEE DETAIL'D'
1'-0" MAX
ORIFICE 2
PVC PIPE STUB SHEAR GATE
IE 449.40
SHIELDED SEE DETAIL'C'
0.875" = 7/8"
DIET SEE D
2�
COUPLING INVERT
0.5'
GASKET (TYP) o
12" RISER
OVERFLOW ELEVATION 474.00 -- —
— — — — — 12" RISER PIPE
1/4"
PIPE
PVC ADAPTER W/ DOUBLE
RECTANGULAR WEIR 473.05
SUPPORT (2 MIN.)
GASKET AND ADHESIVE �'
SEE DETAIL'A'
BONDED SAND FINISH ON ORIFICE PLATE
EXTERIOR, MIN 7" LONG ORIFICE 1 DIAMETER*
ORIFICE 2
IE 471.98
CAULK SPACE BETWEEN PVC PIPE
CROSS
0.5" = 1/2"
PVC ADAPTER AND PIPE STUB
SEE DETAIL'D'
12" SDINLET
12" SD OUTLET
DETAIL B: CONNECTION &
12" SD INLET
12" SD OUTLET
IE 470.36
IE 470.36
CONTROL DEVICE
IE 444.00
IE 444.00
NOTES:
1. PVC PIPE MUST BE SCHEDULE 40, PER ASTM 1785.
2. *CONSTRUCTION DRAWINGS MUST PROVIDE ELEVATION AND DIAMETER FOR
TYPE 2 N
CATCH BASIN
SUPPORT (2 MIN.)
TYPE 2
CATCH BASIN
N
SUPPORT (2 MIN.)
SEE DETAIL'A'
ORIFICE 1 AND ORIFICE 2 AND DIMENSIONS AND ELEVATION FOR THE
SEE DETAIL'A'
BOTTOM OF THE V-NOTCH WEIR AND ELEVATION FOR OVERFLOW.
3. FIELD CHANGES TO DETENTION PIPE INVERT AND SLOPE REQUIRE
SEE DETAILS
3 5
SEE DETAILS
3 5
ORIFICE 1
CONFIRMATION FROM THE ENGINEER OF RECORD THAT THE CONSTRUCTION
cs1 c310
cs1 c310
N IE 468.36
DRAWING ELEVATIONS FOR THE FLOW CONTROL DEVICE ASSEMBLY STILL
N
ORIFICE 1
54" 0.875"= 7/8"
MEET THE DESIGN REQUIREMENTS.
IE 442.00
SEE DETAIL'B'
54"
1"
SEE DETAIL'B'
77
o
NEOPRENE
REFERENCE CITY OF RENTON CONTROL
REFERENCE CITY OF RENTON CONTROL
GASKET LIFT GATE AND PIPE
STRUCTURE DETAIL FOR ADDITIONAL INFORMATION
STRUCTURE DETAIL FOR ADDITIONAL INFORMATION
SEE DETAIL S/SHEET C310
SEE DETAIL S/SHEET C310
C
LIFT GATE
i
CONTROL ROD N/ELDED GATE
ASSEMBLY TO PIPE
\
12" SD
12" SD
SD
INLET
N
INLET
OUTLET
DETAIL C: LIFT GATE ASSEMBLY
�
ELBOW STAND PIPE WALL
I
STUB WELDED TO STAND PIPE
IE PER PLANS
12" SD
OUTLET
ORIFICE PLATE WELDED 6" BAND ELBOW WITH REMOVABLE
TO STUB ORIFICE WATER TIGHT COUPLING
DETAIL D: SECONDARY ORIFICE
SD Al CONTROL STRUCTURE
SD C1
CONTROL STRUCTURE
-
-
NTS
Scale:1"=2'
Scale: 1'L2'
NTS A
'�F
Control Structure Details
Control Structure
Al (Baseball Field)
Control Structure C1 (Softball Field)
Not Used
R-432634
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING t rIL
msippo 08/07/2025
{� A• e/ A
SURVEYED:
sue:
HORIZONTAL: N D 1983/1991
N/A
CITY ��
HAZEN HIGH SCHOOL MODERNIZATION
�o7.1 1.2025
W
DESIGNED:JAJ
FlELDBOOK:
DRAWN:
RENTON
PAGE:
DJD/AJJ
ONE INCH
DATUM
DRAWING NO:
NTS
�E�iS-F0L °
s �,
CHECKED:
JAJ
AT FULL s�LE Planning/Building/Public
IF NOT DNE INCH
Works De t.
p
DRAINAGE DETAILS
C3 1 3
Not Used
C
S,�N�L v�
N0.
REVISION
BY DATE APPR APPROVED:
SCALE ACCORDINGLY
SHEET: OF:
05 29 20 5
JAJ
I 1
1
34 OF 7
T
O
N
A,
u
NJ -
CM
O
O
i
N
Q
J
O
O
N
cc
,@I