HomeMy WebLinkAboutR-432637STORMTRAP MODULE LIFTING SPECIFICATION 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT ALL (4) CHAINS/CABLES ARE SECURED PROPERLY TO THE LIFTING ANCHORS AND IN EQUAL TENSION WHEN LIFTING THE STORMTRAP MODULE. 2. MINIMUM 7'-0" CHAIN/CABLE LENGTH TO BE USED TO LIFT STORMTRAP MODULES (SUPPLIED BY CONTRACTOR). 3. CONTRACTOR TO ENSURE MINIMUM LIFTING ANGLE IS 60' FROM TOP SURFACE OF STORMTRAP MODULE. SEE DETAIL. 4. IT IS UNDERSTOOD AND AGREED THAT AT ALL TIMES DURING WHICH HOISTING AND RIGGING EQUIPMENT IS BEING SUPPLIED TO THE PURCHASER, OPERATOR OF SUCH EQUIPMENT SHALL BE IN CHARGE OF HIS ENTIRE EQUIPMENT AND SHALL AT ALL TIMES BE THE JUDGE OF THE SAFETY AND PROPERTY OF ANY SUGGESTION TO HIM FROM THE SELLER, ITS AGENTS OR EMPLOYEES. PURCHASER AGREES TO SAVE, INDEMNIFY AND HOLD HARMLESS SELLER FROM ALL LOSS, CLAIMS, DEMANDS OR CAUSES OF ACTION, WHICH MAY ARISE FROM THE EXISTENCE OR OPERATION OF SAID EQUIPMENT. ACCESS OPENING SPECIFICATION 1. A TYPICAL ACCESS OPENING FOR THE STORMTRAP SYSTEM ARE 2'-0" IN DIAMETER. ACCESS OPENINGS LARGER THAN 4'-0" IN DIAMETER NEED TO BE APPROVED BY STORMTRAP. ALL OPENINGS MUST RETAIN AT LEAST 2'-0" OF CLEARANCE FROM THE END OF THE STORMTRAP MODULE UNLESS NOTED OTHERWISE. ALL ACCESS OPENINGS TO BE LOCATED ON INSIDE LEG UNLESS OTHERWISE SPECIFIED. SEE SHEET 2.0 FOR SIZES AND LOCATIONS. 2. UNLESS OTHERWISE SPECIFIED, PLASTIC COATED STEEL STEPS PRODUCED BY M.A. INDUSTRIES PART #PS3-PFC OR APPROVED EQUAL (SEE STEP DETAIL) ARE PROVIDED INSIDE ANY MODULE WHERE DEEMED NECESSARY. THE HIGHEST STEP IN THE MODULE IS TO BE PLACED A DISTANCE OF 1'-0" FROM THE INSIDE EDGE OF THE STORMTRAP MODULES. ALL ENSUING STEPS SHALL BE PLACED AT A DISTANCE BETWEEN 10" MIN AND 14" MAX BETWEEN THEM. STEPS MAY BE MOVED OR ALTERED TO AVOID OPENINGS OR OTHER IRREGULARITIES IN THE MODULE. 3. STORMTRAP LIFTING INSERTS MAY BE RELOCATED TO AVOID INTERFERENCE WITH ACCESS OPENINGS OR THE CENTER OF GRAVITY OF THE MODULE AS NEEDED. 4. STORMTRAP ACCESS OPENINGS MAY BE RELOCATED TO AVOID INTERFERENCE WITH INLET AND/OR OUTLET PIPE OPENINGS SO PLACEMENT OF STEPS IS ATTAINABLE. 5. ACCESS OPENINGS SHOULD BE LOCATED IN ORDER TO MEET THE APPROPRIATE MUNICIPAL REQUIREMENTS. STORMTRAP RECOMMENDS AT LEAST TWO ACCESS OPENINGS PER SYSTEM FOR ACCESS AND INSPECTION. 6. USE PRECAST ADJUSTING RINGS AS NEEDED TO MEET GRADE. STORMTRAP RECOMMENDS FOR COVER OVER 2' TO USE PRECAST BARREL OR CONE SECTIONS. (PROVIDED BY OTHERS) PIPE OPENING SPECIFICATION 1. MINIMUM EDGE DISTANCE FOR AN OPENING ON THE OUTSIDE WALL SHALL BE NO LESS THAN 1'-0". 2. CONNECTING PIPES MAY BE INSTALLED WITH A 1'-0" CONCRETE COLLAR AND AN AGGREGATE CRADLE (AS REQUIRED) FOR AT LEAST ONE PIPE LENGTH (SEE PIPE CONNECTION DETAIL). A STRUCTURAL GRADE CONCRETE OR HIGH STRENGTH, NON -SHRINK GROUT WITH A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI MAY BE USED. 3. THE ANNULAR SPACE BETWEEN THE PIPE AND THE HOLE SHALL BE FILLED WITH HIGH STRENGTH NON -SHRINK GROUT. PIPE INSTALLATION INSTRUCTIONS 1. CLEAN AND LIGHTLY LUBRICATE ALL OF THE PIPE TO BE INSERTED INTO STORMTRAP. 2. IF PIPE IS CUT, CARE SHOULD BE TAKEN TO ALLOW NO SHARP EDGES. BEVEL AND LUBRICATE LEAD END OF PIPE. 3. ALIGN CENTER OF PIPE TO CORRECT ELEVATION AND INSERT INTO OPENING. NOTE: ALL ANCILLARY PRODUCTS/SPECIFICATIONS RECOMMENDED AND SHOWN ON THIS SHEET INCLUDING BUT NOT LIMITED TO CONCRETE COLLARS, AGGREGATE CRADLES, GRADE RINGS, RISER SECTIONS, ETC., ARE RECOMMENDATIONS ONLY AND SUBJECT TO CHANGE PER THE INSTALLING CONTRACTOR AND/OR PER LOCAL MUNICIPAL CODE/REQUIREMENTS. END PANEL LIFTING DETAIL END PANEL ERECTION/INSTALLATION SPECIFICATION 1. END PANELS WILL BE SUPPLIED TO CLOSE OFF OPEN ENDS OF ROWS. 2. PANELS SHALL BE INSTALLED IN A TILT UP FASHION DIRECTLY ADJACENT TO OPEN END OF MODULE (REFER TO SHEET 2.0 FOR END PANEL LOCATIONS). 3. CONNECTION HOOKS WILL BE SUPPLIED WITH END PANELS TO SECURELY CONNECT PANEL TO ADJACENT STORMTRAP MODULE (SEE PANEL CONNECTION ELEVATION VIEW). 4. ONCE CONNECTION HOOK IS ATTACHED, LIFTING CLUTCHES MAY BE REMOVED. 5. JOINT WRAP SHALL BE PLACED AROUND PERIMETER JOINT PANEL (SEE SHEET 3.0). CONNECTION HOOKS PROVIDED BY STORMTRAP AND INSTALLED BY CONTRACTOR (SEE DETAIL 6) 1" 6 HOOK C01 TO SIDE CF STORMTRAP MODULE SIDE CIF END PANEL PANEL CONNECTION ELEVATION VIEW �1'-4"-----{ MEETS: SPECIFIED BY ENGINEE OPSS 1351.08.02 (SUPPLIED BY OTHER`. t�• BNQ ASTM C-478.95a ASTM D4-101.95b PRECAST CONCRETE ADJUSTING RING: BARREL OR CONE SECTIONS AS NEEDE AASHTO M-199 SEE ACCESS OPENING SPECIFICATION NOTE I ASTM 4A-15 (SUPPLIED BY OTHER: NON -SHRINK GROU r-s;• to3" STORMTRAP MODULE STEP DETAIL ••• NOTICE "" 03-25-2022 DUE TO CURRENT INCONSISTENCIES IN THE 16" STEP SUPPLY, STORMTRAP MAY SUBSTITUTE THE 16" STEP WITH THE CLOSEST ALTERNATIVE LENGTH STEP UNTIL THE SUPPLY CHAIN ISSUE IS RESOLVED. WALL OF STORMTRAP STEP 1 STEP 2 DETAIL 6 RISER/STAIR DETAIL V-O" x 1'-0" CONCRETE COLLAR (AS REQUIRED) HIGH STRENGTH, INLET/OUTLET PIPE NON -SHRINK GROUT r AGGREGATE CRADLE (AS REQUIRED) STORMTRAP MODULE BASE SLAB IF A PIPE IS PROPOSED AT THE SYSTEM INVERT, NOTCH PIPE TO ALLOW PIPE INVERT TO MEET SYSTEM INVERT NOTCHED PIPE CONNECTION DETAIL WHEN PIPE INVERT IS AT INVERT OF STORMTRAP SYSTEM 43667 9 'rsTE4�' 6 IVA1, 061 i StormTrap. na.�s umD AT D�/AIaBIV►m141mQ 1287 WINDHAM PAFMY ROMEOv1LLE, IL 60446 P.815-941-4518 / F.331 318-5347 ENGINEER INFORMATION: Jacobson Consulting Engineers 255 S. King St. Suite 800 Seattle, WA 98104 206-426-2600 PROJECT INFORMATION: Hazen High School 1101 Hoquiam Ave NE Renton, WA 98059 CURRENT ISSUE DATE: 6/12/2025 ISSUED FOR: CONSTRUCTION REV. DATE: ISSUED FOR. BY: XX/XX/XX CONSTRUCTION DG 5 5/19/2025 APPROVAL SB 4 5/13/2025 APPROVAL SB 3 3/19/2025 PRELIMINARY ZM 2 2/11/2025 PRELIMINARY ZM 1 10/25/2D24 PRELIMINARY DG SCALE: Nrs SHEET TITLE: DOUBLETRAP INSTALLATION SPECIFICATION SHEET NUMBER: 3.1 StormTrape PAMs u1MD AE DnP✓/nwa►mV11u1M0 1297 WNDFWM PAIMWAY ROMEOJILLE, IL 60446 1-815-941-4W. / F.331-3183347 ENGINEER INFORMATION: Jacobson Consulting Engineers 255 S. King St. Suite 800 Seattle, WA 98104 206-426-2600 PROJECT INFORMATION: Hazen High School 1101 Hoquiam Ave NE Renton, WA 98059 CURRENT ISSUE DATE: 6/12/2025 ISSUED FOR: CONSTRUCTION REV, DATE: ISSUED FOR. OWN XX/XX/XX CONSTRUCTION DG 5 5/19/2025 APPROVAL SB 4 5/13/2025 APPROVAL SB 3 3/19/2025 PREUMINARY ZM 2 2/11/2025 PREUMINARY ZM 1 10/25/2024 PRELIMINARY DG SCALE: NTS SHEET TITLE: PIPE / ACCESS OPENING SPECIFICATION SHEET NUMBER: 5.0 ZONE CHART ZONES ZONE DESCRIPTIONS REMARKS ZONE 1 FOUNDATION AGGREGATE 5 (t") STONE ANGULAR AGGREGATE (rSEE NOTE 4) ZONE 2 BACKFILL UNIFIED SOILS CLASSIFICATION (GW, GP, SW, SP) OR SEE BELOW FOR APPROVED BACKFILL OPTIONS ZONE 3 FINAL COVER OVERTOP MATERIALS NOT TO EXCEED 120 PCF APPROVED ZONE 2 BACKFILL OPTIONS OPTION REMARKS THE STONE AGGREGATE SHALL CONSIST OF CLEAN AND FREE DRAINING ANGULAR MATERIAL. THE SIZE OF THIS MATERIAL SHALL HAVE 100% PASSING THE 1" SIEVE WITH STONE 0% TO 5X PASSING THE #8 SIEVE. THIS MATERIAL SHALL BE SEPARATED FROM NATIVE AGGREGATE MATERIAL USING GEOFABRIC AROUND THE PERIMETER OF THE BACKFILL (ASTM SIZE #57) AS DETERMINED BY THE GEOTECHNICAL ENGINEER. IMPORTED PURE SAND IS PERMITTED TO BE USED AS BACKFILL IF IT IS CLEAN AND FREE DRAINING. THE SAND USED FOR BACKFILLING SHALL HAVE LESS THAN 40X SAND PASSING #40 SIEVE AND LESS THAN 59 PASSING #200 SIEVE. THIS MATERIAL SHALL BE SEPARATED FROM NATIVE MATERIAL USING GEOFABRIC AROUND THE PERIMETER OF THE SAND BACKFILL. CLEAN, FREE DRAINING CRUSHED CONCRETE AGGREGATE MATERIAL CAN BE USED AS CRUSHED BACKFILL FOR STORMTRAP-1 MODULES. THE SIZE OF THIS MATERIAL SHALL HAVE 100% CONCRETE PASSING THE 1" SIEVE WITH 0% TO 5X PASSING THE /8 SIEVE. THIS MATERIAL SHALL BE AGGREGATE SEPARATED FROM NATIVE MATERIAL USING GEOFABRIC AROUND THE PERIMETER OF THE BACKFILL. STONE AGGREGATE 100% PASSING THE 1-1/2" SIEVE WITH LESS THAN 12X PASSING ROAD PACK THE #200 SIEVE (ASTM SIZE #467). GEOFABRIC AS PER GEOTECHNICAL ENGINEER RECOMMENDATION. AS RE, ZONE STORMTRAP ZONE INSTALLATION SPECIFICATION/PROCEDURE 1. THE FILL PLACED AROUND THE STORMTRAP MODULES MUST BE DEPOSITED ON BOTH SIDES AT THE SAME TIME AND TO APPROXIMATELY THE SAME ELEVATION. AT NO TIME SHALL THE FILL BEHIND ONE SIDE WALL BE MORE THAN 2'-0" HIGHER THAN THE FILL ON THE OPPOSITE SIDE. BACKFILL SHALL EITHER BE COMPACTED AND/OR VIBRATED TO ENSURE THAT BACKFILL AGGREGATE/STONE MATERIAL IS WELL SEATED AND PROPERLY INTER LOCKED. CARE SHALL BE TAKEN TO PREVENT ANY WEDGING ACTION AGAINST THE STRUCTURE, AND ALL SLOPES WITHIN THE AREA TO BE BACKFILLED MUST BE STEPPED OR SERRATED TO PREVENT WEDGING ACTION. CARE SHALL ALSO BE TAKEN AS NOT TO DISRUPT THE JOINT WRAP FROM THE JOINT DURING THE BACKFILL PROCESS. BACKFILL MUST BE FREE -DRAINING MATERIAL. SEE ZONE 2 BACKFILL CHART ON THIS PAGE FOR APPROVED BACKFILL OPTIONS. IF NATIVE EARTH IS SUSCEPTIBLE TO MIGRATION, CONFIRM WITH GEOTECHNICAL ENGINEER AND PROVIDE PROTECTION AS REQUIRED (PROVIDED BY OTHERS). ALL MODULES MUST BE SET AND ALL SIDES MUST BE FULLY BACKFILLED BEFORE TRAVEL OVERTOP THE SYSTEM IS PERMITTED. SEE NOTE 2 FOR EXCEPTIONS AND LIMITATIONS. 2. THE FILL PLACED OVERTOP THE SYSTEM SHALL BE PLACED IN MINIMUM 6" LIFTS. AT NO TIME SHALL MACHINERY OR VEHICLES GREATER THAN THE DESIGN LIVE LOAD LISTED ON SHEET 1.0 TRAVEL OVERTOP THE SYSTEM. IF TRAVEL OVER THE SYSTEM OCCURS BEFORE THE MINIMUM DESIGN COVER IS ACHIEVED, IT MAY BE NECESSARY TO REDUCE THE ULTIMATE LOAD/BURDEN OF THE OPERATING MACHINERY SO AS TO NOT EXCEED THE DESIGN CAPACITY OF THE SYSTEM. VEHICLES AND MACHINERY USED TO PLACE FILL MATERIAL ON TOP OF THE SYSTEM SHALL TRAVEL PARALLEL TO THE LONGITUDINAL AXIS OF THE STORMTRAP MODULES WHENEVER POSSIBLE. 3. THE VIBRATORY FUNCTION OF ANY ROLLER, COMPACTOR, VEHICLE, ETC. SHALL NOT BE USED OVERTOP THE SYSTEM WITHOUT PRIOR APPROVAL FROM STORMTRAP. IN SOME CASES. HAND COMPACTION MAY BE NECESSARY TO ENSURE THA" THE ALLOWABLE DESIGN LOADING IS NOT EXCEEDED. 4. STONE AGGREGATE FOUNDATION IN ZONE 1 IS RECOMMENDED FOR LEVELING PURPOSES ONLY (OPTIONAL). APPLICABLE OSHA REQUIREMENTS BACKFILL DETAIL (SEE INSTALLATION SPECIFICATIONS) TYPE I TYPE III NOTES: 1. OPENING LOCATIONS AND SHAPES MAY VARY. 2. SP - INDICATES A MODULE WITH MODIFICATIONS. 3. P - INDICATES A MODULE WITH A PANEL ATTACHMENT. 4. POCKET WINDOW OPENINGS ARE OPTIONAL. iIF WREM _ JO JO SURVEYED: DESIGNED: JAJ DRAWN: DJD/AJJ CHECKED: JAJ APPROVED: JAJ SCALE: N/A ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM TYPE II TYPE IV CITY OF RENTON Planning/Building/Public Works Dept. ABRIC/GEOTEXTILE EQUIRED PER APPROVED 2 BACKFILL OPTIONS. TYPE II END PANEL TYPE IV END PANEL StormTrap° Rosa usm ,m pen/plwRPm1Am10 1287 WINDFWM PA%MfAY ROMECMLLE, IL 60446 P.815-941-4548 / F.331-318-5a347 ENGINEER INFORMATION: Jacobson Consulting Engineers 255 S. King St. Suite 800 Seattle, WA 98104 206-426-2600 PROJECT INFORMATION: Hazen High School 1101 Hoquiam Ave NE Renton, WA 98059 CURRENT ISSUE DATE: 6/12/2025 ISSUED FOR: CONSTRUCTION EV DATE: ISSUED FOR: BWN j XX/XX/XX CONSTRUCTION DG 5 5/19/2025 APPROVAL SB 4 5/13/2025 APPROVAL SB 3 3/19/2025 PRELIMINARY ZM 2 2/11/2025 PRELIMINARY ZM 1 10/25/2024 PRELIMINARY DC SCALE: NFS SHEET TITLE: DOUBLETRAP BACKFILL SPECIFICATION SHEET NUMBER: 4.0 StormTrNap- 110BR UM a DoP✓/A=~4l3~ 1287 WINDHAM PARI(WAY ROMEOALLE, IL 60446 P.815-941-4518 / F-331-318-5347 ENGINEER INFORMATION: Jacobson Consulting Engineers 255 S. King St. Suite 800 Seattle, WA 98104 206-426-2600 PROJECT INFORMATION: Hazen High School 1101 Hoquiam Ave NE Renton, WA 98059 CURRENT ISSUE DATE: 6/12/2025 ISSUED FOR: CONSTRUCTION REV.DATE: ISSUED FOR. BWN XX/XX/XX CONSTRUCTION DG 5 5/19/2025 APPROVAL SB 4 5/13/2025 APPROVAL SB 3 3/19/2025 PRELIMINARY ZM 2 2/11/2025 PRELIMINARY ZM 1 10/25/2D24 PRELIMINARY DG SCALE: HFS SHEET TITLE: DOUBLETRAP MODULE TYPES SHEET NUMBER: 60 NTS StormTrap Details R-432637 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Yr %' IL msippo 08/07/2025 HAZEN HIGH SCHOOL MODERNIZATION DRAINAGE DETAILS DATE: 07.1 1 .2025 PAGE: C317 SHEET. OF. 37 OF 7 T N C) N �J m M O C) O I N Q J 00 C) C) O N rr Is's