HomeMy WebLinkAboutR-432660N
w
I-
3
it
M
J
a
J
\1
A
t--
Ll
�, POC PLAN ENLARGEMENT
1/8" = 1'-0"
SPECIFIED 10" ROUND
VALVE BOX AND LID
1 /4" GALV. U-BOLT
1 " X 16" SCH. 40
PVC PIPE
SUPPORT EACH VALVE BOX
WITH (4) BRICKS, TYP.
MINIMUM 2 C.F. (12" DEPTH)
DRAIN ROCK SUMP
ELEVATION VIEW
P-HA1-36
SPECIFIED 10" ROUND
VALVE BOX, INSTALL
FLUSH WITH FINISH GRADE
QUICK COUPLER VALVE
FINISH GRADE
1 " X 16" SCH. 40 PVC
PIPE, SECURE TO QUICK
COUPLER WITH 1 /4"
GALV. U-BOLT
BUSHING AS REQUIRED
SCH. 80 NIPPLE, VARIABLE
LENGTH AS REQUIRED
(2) SCH. 80 STREET ELL
W/(1) SCH. 80 SHORT
NIPPLE (NO MARLEX)
PVC SCH. 80 NIPPLE,
8" MIN. LENGTH
MAINLINE
PVC TH X TH 90 DEG. ELL
(NO STREET ELL)
NOTES:
1. ALL THE FITTINGS AND PIPE TO BE SAME DIA. AS IPS FEMALE CONNECTION OF QUICK COUPLER.
2. QUICK COUPLER KEY MUST CLEAR VALVE BOX.
QUICK COUPLER VALVE
1 1/2" = 1'-0"
P-HA1-26
ET MANAGER RECEIVER IF
SPECIFIED ON LEGEND
SPECIFIED AUTOMATIC IRRIGATION
CONTROLLER. WALL MOUNT IN
SPECIFIED METAL PEDESTAL
CABINET PER MANUFACTURER'S
RECOMMENDATION. SEE
IRRIGATION PLAN FOR LOCATION.
ELECTRICAL CONDUIT FOR
POWER SOURCE
CONDUIT FOR CONTROL WIRES,
MINIMUM SIZE AS SPECIFIED
ON IRRIGATION PLANS
FINISH GRADE
DIRECT BURIAL
CONTROL WIRES
NOTE:
1. INSTALL GROUNDING ROD AND WIRING PER LEGEND AND PER
MANUFACTURER'S RECOMMENDATION.
IRRIGATION CONTROLLER (EXTERIOR PEDESTAL)
3/4" = 1'-0"
FLOW SENSOR
WITH TEE
Igm,1 lael:"B]g
I
it z
MAINLINE
STRAIGHT RUN OF PIPE
FLOW MIN. 10X PIPE DIA.
FOR CONVENTIONAL Cb�C
SYSTEM, INSTALL
CONDUIT WITH PE-89
CABLE TO CONTROLLER
ELEVATION VIEW
P-HA1-30
SPECIFIED RECTANGULAR VALVE
BOX, INSTALL FLUSH WITH
FINISH GRADE
SPECIFIED CONTROL WIRES
& SPLICE KITS
INSTALL DECODER FOR TWO -WIRE
SYSTEM AND PULSE TRANSMITTER
ON CONVENTIONAL SYSTEM
Of
I wo
C/) a
STRAIGHT RUN OF PIPE N
FLOW MIN. 5X PIPE DIA.
SUPPORT VALVE BOX
WITH (4) BRICKS
INSTALL 6" DEPTH MIN. OF
DRAIN ROCK IN BOTTOM OF
VALVE BOX. EXTEND ROCK
6" BEYOND VALVE BOX
NOTES:
1. INSTALL FLOW SENSOR AS PER THE MANUFACTURER'S RECOMMENDATIONS.
2. PROVIDE VALVE BOX EXTENSION AS REQUIRED.
3. INSTALL FLOW SENSOR PERFECTLY PLUMB.
FLOW SENSOR
1 1/2" = 1'-0"
N0.
REVISION
SURVEYED:
DESIGNED:
DRAWN:
CHECKED:
BY I DATE I APPR I APPROVED
P-HA1-17
T
TWO (2) SPECIFIED
Ln
RECTANGULAR VALVE BOXES
O
WITH LOCKING LIDS. BOLT
BOXES TOGETHER
N
FINISH GRADE U
SPECIFIED DRAIN VALVE
MAINLINE
PVC WITH THREADED OUTLET
PIPE MIN. 18" OFFSET
FROM PVC LINE
3" PVC PIPE, THREADED
ONE END
MIN. 3 C.F. (24" DEPTH)
DRAIN ROCK SUMP
ELEVATION VIEW
NOTES:
1. ALL PIPE AND FITTINGS TO BE SAME DIA. AS I.P.S. FEMALE CONNECTION TO DRAIN VALVE.
2. INSTALL ONE MANUAL DRAIN VALVE AT LOWEST POINT OF MAINLINE ON SITE, SUBJECT TO REVIEW AND
APPROVAL BY LANDSCAPE ARCHITECT PRIOR TO INSTALLATION.
MANUAL DRAIN VALVE
1 1/2" = 1'-0"
SPECIFIED RECTANGULAR
VALVE BOX, INSTALL TOP OF
LID FLUSH WITH FINISH GRADE
SPECIFIED AUTOMATIC
CONTROL VALVE,
INSTALL PRESSURE
REGULATING DIAL IF SHOWN
ON LEGEND
I
PVC UNION--,,
24" SPARE WIRE
COIL, SEE SPECS
FOR QUANTITY
PVC BALL VALVE,
COMMERCIAL GRADE
SO II
P I(f CLR.
,S►B�eL'Lj0]2I
SPECIFIED SPLICE KITS
m 24" CONTROL WIRE
COIL IN BOX
1" MIN. CLEARANCE
_ BETWEEN VALVE BOX
AND PIPE
PVC UNION -j
PROVIDE CORRECT SIZE
NIPPLE SO THAT LATERAL
LINE COMES RIGHT OUT OF
THE BOX WITHOUT USING 90
DEG. ELLS OR 45 DEG. ELL.
MAINLINE, SIZE PER PLAN
CONTROL AND SPARE WIRES,
TAPE TO BOTTOM OF MAINLINE
ELEVATION VIEW
NOTE:
PROVIDE VALVE BOX EXTENSIONS AS REQUIRED.
PVC LATERAL PIPE
P-HA1-20
C/)w
z
0
F
aJ
w
U Q w
wJ
teary
wOfm
ww
SUPPORT VALVE BOX
WITH (4) BRICKS
MINIMUM 2 C.F. (12" DEPTH)
DRAIN ROCK SUMP IN
BOTTOM OF VALVE BOX.
6 REMOTE CONTROL VALVE - WITH SHUT-OFF
1 1/2" = 1'-0"
SCALE:
1 if 0'
ONE INCH
AT FULL SOME
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
•
® C TY OF
RENTON
[;R
Planning/Building/Public Works Dept.
R-432660
IN COMPUMIGE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING
V .j-
amorganroth
08/08/2025
[DEV7EL0PIMENT ENGINEERING
o 08/07/2025 :01
DATE:
HAZEN HIGH SCHOOL MODERNIZATION 07.11.2025
FIELDBOOK:
PAGE:
DRAWING NO:
IRRIGATION DETAILS L305
SHEET: OF:
60 OF 7E