HomeMy WebLinkAboutR-432660N w I- 3 it M J a J \1 A t-- Ll �, POC PLAN ENLARGEMENT 1/8" = 1'-0" SPECIFIED 10" ROUND VALVE BOX AND LID 1 /4" GALV. U-BOLT 1 " X 16" SCH. 40 PVC PIPE SUPPORT EACH VALVE BOX WITH (4) BRICKS, TYP. MINIMUM 2 C.F. (12" DEPTH) DRAIN ROCK SUMP ELEVATION VIEW P-HA1-36 SPECIFIED 10" ROUND VALVE BOX, INSTALL FLUSH WITH FINISH GRADE QUICK COUPLER VALVE FINISH GRADE 1 " X 16" SCH. 40 PVC PIPE, SECURE TO QUICK COUPLER WITH 1 /4" GALV. U-BOLT BUSHING AS REQUIRED SCH. 80 NIPPLE, VARIABLE LENGTH AS REQUIRED (2) SCH. 80 STREET ELL W/(1) SCH. 80 SHORT NIPPLE (NO MARLEX) PVC SCH. 80 NIPPLE, 8" MIN. LENGTH MAINLINE PVC TH X TH 90 DEG. ELL (NO STREET ELL) NOTES: 1. ALL THE FITTINGS AND PIPE TO BE SAME DIA. AS IPS FEMALE CONNECTION OF QUICK COUPLER. 2. QUICK COUPLER KEY MUST CLEAR VALVE BOX. QUICK COUPLER VALVE 1 1/2" = 1'-0" P-HA1-26 ET MANAGER RECEIVER IF SPECIFIED ON LEGEND SPECIFIED AUTOMATIC IRRIGATION CONTROLLER. WALL MOUNT IN SPECIFIED METAL PEDESTAL CABINET PER MANUFACTURER'S RECOMMENDATION. SEE IRRIGATION PLAN FOR LOCATION. ELECTRICAL CONDUIT FOR POWER SOURCE CONDUIT FOR CONTROL WIRES, MINIMUM SIZE AS SPECIFIED ON IRRIGATION PLANS FINISH GRADE DIRECT BURIAL CONTROL WIRES NOTE: 1. INSTALL GROUNDING ROD AND WIRING PER LEGEND AND PER MANUFACTURER'S RECOMMENDATION. IRRIGATION CONTROLLER (EXTERIOR PEDESTAL) 3/4" = 1'-0" FLOW SENSOR WITH TEE Igm,1 lael:"B]g I it z MAINLINE STRAIGHT RUN OF PIPE FLOW MIN. 10X PIPE DIA. FOR CONVENTIONAL Cb�C SYSTEM, INSTALL CONDUIT WITH PE-89 CABLE TO CONTROLLER ELEVATION VIEW P-HA1-30 SPECIFIED RECTANGULAR VALVE BOX, INSTALL FLUSH WITH FINISH GRADE SPECIFIED CONTROL WIRES & SPLICE KITS INSTALL DECODER FOR TWO -WIRE SYSTEM AND PULSE TRANSMITTER ON CONVENTIONAL SYSTEM Of I wo C/) a STRAIGHT RUN OF PIPE N FLOW MIN. 5X PIPE DIA. SUPPORT VALVE BOX WITH (4) BRICKS INSTALL 6" DEPTH MIN. OF DRAIN ROCK IN BOTTOM OF VALVE BOX. EXTEND ROCK 6" BEYOND VALVE BOX NOTES: 1. INSTALL FLOW SENSOR AS PER THE MANUFACTURER'S RECOMMENDATIONS. 2. PROVIDE VALVE BOX EXTENSION AS REQUIRED. 3. INSTALL FLOW SENSOR PERFECTLY PLUMB. FLOW SENSOR 1 1/2" = 1'-0" N0. REVISION SURVEYED: DESIGNED: DRAWN: CHECKED: BY I DATE I APPR I APPROVED P-HA1-17 T TWO (2) SPECIFIED Ln RECTANGULAR VALVE BOXES O WITH LOCKING LIDS. BOLT BOXES TOGETHER N FINISH GRADE U SPECIFIED DRAIN VALVE MAINLINE PVC WITH THREADED OUTLET PIPE MIN. 18" OFFSET FROM PVC LINE 3" PVC PIPE, THREADED ONE END MIN. 3 C.F. (24" DEPTH) DRAIN ROCK SUMP ELEVATION VIEW NOTES: 1. ALL PIPE AND FITTINGS TO BE SAME DIA. AS I.P.S. FEMALE CONNECTION TO DRAIN VALVE. 2. INSTALL ONE MANUAL DRAIN VALVE AT LOWEST POINT OF MAINLINE ON SITE, SUBJECT TO REVIEW AND APPROVAL BY LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. MANUAL DRAIN VALVE 1 1/2" = 1'-0" SPECIFIED RECTANGULAR VALVE BOX, INSTALL TOP OF LID FLUSH WITH FINISH GRADE SPECIFIED AUTOMATIC CONTROL VALVE, INSTALL PRESSURE REGULATING DIAL IF SHOWN ON LEGEND I PVC UNION--,, 24" SPARE WIRE COIL, SEE SPECS FOR QUANTITY PVC BALL VALVE, COMMERCIAL GRADE SO II P I(f CLR. ,S►B�eL'Lj0]2I SPECIFIED SPLICE KITS m 24" CONTROL WIRE COIL IN BOX 1" MIN. CLEARANCE _ BETWEEN VALVE BOX AND PIPE PVC UNION -j PROVIDE CORRECT SIZE NIPPLE SO THAT LATERAL LINE COMES RIGHT OUT OF THE BOX WITHOUT USING 90 DEG. ELLS OR 45 DEG. ELL. MAINLINE, SIZE PER PLAN CONTROL AND SPARE WIRES, TAPE TO BOTTOM OF MAINLINE ELEVATION VIEW NOTE: PROVIDE VALVE BOX EXTENSIONS AS REQUIRED. PVC LATERAL PIPE P-HA1-20 C/)w z 0 F aJ w U Q w wJ teary wOfm ww SUPPORT VALVE BOX WITH (4) BRICKS MINIMUM 2 C.F. (12" DEPTH) DRAIN ROCK SUMP IN BOTTOM OF VALVE BOX. 6 REMOTE CONTROL VALVE - WITH SHUT-OFF 1 1/2" = 1'-0" SCALE: 1 if 0' ONE INCH AT FULL SOME IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM • ® C TY OF RENTON [;R Planning/Building/Public Works Dept. R-432660 IN COMPUMIGE WITH CITY OF RENTON STANDARDS CURRENT PLANNING V .j- amorganroth 08/08/2025 [DEV7EL0PIMENT ENGINEERING o 08/07/2025 :01 DATE: HAZEN HIGH SCHOOL MODERNIZATION 07.11.2025 FIELDBOOK: PAGE: DRAWING NO: IRRIGATION DETAILS L305 SHEET: OF: 60 OF 7E