Loading...
HomeMy WebLinkAboutR-432662CM O w 3 I5 0 J Q Ld J POST CAP,- TYP. STRETCHER BAR, TYP. LINE, END AND CORNER POST, TYP. LINE, END AND CORNER POST, TYP. LINE, END AND CORNER POST, TYP. ADJACENT CONDITION REFER TO SITE PLAN TOP RAIL 4 CHAIN LINK FABRIC AND TIES STRETCHER BAR BANDS AT 12" O.C., Q TYP. J In Of w w H c� w BOTTOM RAIL = 2" MAX FINISH GRADE -7— III III II II TOP OF FOOTING 6" BELOW FINISH GRADE III— - ° FOOTING, SIZE NOTES: NOTED BELOW 1. SEE SPECIFICATION SECTION 323113 FOR ADDITIONAL INFORMATION ON POSTS, RAILS, FOOTING AND OTHER COMPONENTS. 2. PROVIDE CONCRETE MOW STRIPS WHERE SHOWN ON DRAWINGS. 3. PROVIDE GALVANIZED FENCE TO MATCH EXISTING AT BASEBALL AND SOFTBALL FIELD. INSTALL BLACK VINYL CHAIN LINK FENCE WITH SIGHT OBSCURING SLATS WHERE NOTED ON PLAN. 4. ALL MESH OPENING TO BE 2" OR OTHERWISE NOTED ON PLAN. 5. PROVIDE CONTROL OR EXPANSION JOINT AT EACH POST LOCATED IN CONCRETE. 6. POST SPACING 10'-0" O.C. MAX. 7. END/CORNER POST FOOTINGS: 12" HOLE DIAMETER, 42" DEEP, 36" POST EMBEDMENT. 8. LINE POST FOOTINGS: 12" HOLE DIAMETER, 36" DEEP, 30" POST EMBEDMENT. 4'-6' HT. CHAIN LINK FENCE 1 /2" = 1'-O" RECYCLED PLASTIC 2X4 NAILER, FASTEN TO CONCRETE WITH 1 /4"X5" GALV. EXPANSION ANCHORS @ 12" O.C. IN ZIG ZAG PATTERN. SET TOP OF NAILER SUCH THAT COMPACTED/SETTLED TURF INFILL WILL BE FLUSH WITH TOP OF RUBBERIZED SURFACING AFTER COMPACTION. CONC. CURB WITH (2) #4 BARS CONTINUOUS. PROVIDE ALTERNATING EXPANSION JOINTS (FULL DEPTH OF CURB) AND CONTROL JOINTS AT 10' O.C. TOP OF NEW CONCRETE CURB TO BE FLUSH WITH TOP OF EXISTING ASPHALT EXISTING PAVING TO REMAIN, PRESERVE AND PROTECT. SAW CUT 1 "-15" FROM EXISTING EDGE ACCORDING TO NEW CONCRETE CURB LOCATION d a 77 a 4 I° V ° C P-HA1-04 FASTEN TURF FABRIC MAT TO 2X4 RECYCLED PLASTIC NAILER PER TURF MFR.'S RECOMMENDATION, UTILIZING 1-1/4" S.S. STAPLES. TOP OF E-LAYER TO BE FLUSH WITH TOP OF NAILER SYNTHETIC TURF SECTION SYNTHETIC TURF EDGE ANCHOR AT EXISTING PAVING 1 1 /2" = 1 '-0" P-HA1-14 WIDTHS VARY - SEE PLAN AND GATE SCHEDULE HINGE POST ____ HINGE POST AIIII 3" CLR. MAX ry J U e I - a. FOOTING, SIZE NOTED BELOW MALLEABLE INDUSTRIAL HINGE ° d J U p I 12" DIA. CONC. CENTER STOP WITH PVC SLEEVE INSERT. PROVIDE A SIMILAR STOP FOR EACH GATE ARM TO HOLD IN OPEN POSITION FULCRUM STYLE LOCKABLE GATE FORK LATCI FOR HEAVY DUTY PADLOCK DROP ROD ASSEMBLY ALL JOINTS WELDED TO MAKE SOLID FRAME HOLD TOP OF FOOTING 6" BELOW FINISH GRADE, TYP. STRETCHER BAR (TYP. 4 SIDES) TRUSS RODS W/ TURNBUCKLES, SEE SPECS PROVIDE FIRE DEPARTMENT KNOX BOX, FIELD LOCATE PER FIRE INSPECTOR CHAIN LINK FABRIC AND TIES FINISH GRADE NOTES: 1. SEE SPECIFICATION SECTION 323113 FOR ADDITIONAL INFORMATION ON POSTS, FOOTING AND OTHER COMPONENTS. 2. ALL GATES TO BE INSTALLED PLUMB AND SECURE FOR FULL OPENING WITHOUT INTERFERENCES. 3. ATTACH HARDWARE BY MEANS WHICH WILL PREVENT UNAUTHORIZED REMOVAL. 4. TACK WELD ALL GATE HARDWARE AFTER ADJUSTMENT. 5. ADJUST HARDWARE FOR SMOOTH OPERATION. 6. PROVIDE CANE BOLT AND RECEPTACLE IN PAVEMENT TO SECURE EACH SIDE IN FULLY OPEN POSITION. 7. REFER TO SITE PLAN AND GATE SCHEDULE FOR LOCATIONS OF GALVANIZED OR BLACK VINYL FINISH. 8. ALL MESH OPENING TO BE 2" OR OTHERWISE NOTED ON PLAN. 9. PROVIDE FIRE DEPARTMENT KNOX BOX AS INDICATED ON GATE SCHEDULE. FIELD LOCATE PER FIRE INSPECTOR. 10.GATE POST FOOTINGS: 12" HOLE DIAMETER, 42" DEEP, 42" POST EMBEDMENT. DOUBLE SWING CHAIN LINK GATE 1 /2" = 1'-O" FINISH GRADE SYNTHETIC TURF CARPET AND INFILL, INFILL TO BE FLUSH WITH ADJACENT SURFACE, SEE SPECS. 25 MM E-LAYER PAD, SEE SPECS 2" PERMEABLE TOP STONE, SEE SPECS PERMEABLE BASE STONE, DEPTH VARIES WITH SUBGRADE, MIN. 8", SEE SPECS AND SUBGRADE PLAN GEOTEXTILE FABRIC, TENCATE MIRAFI 140N OR APPROVED EQUAL. OVERLAP MINIMUM 12", SECURELY STAPLE IN -- -- -- -- -- PLACE. ----------- - - -- -- CIVIL DETENTION SYSTEM --------------- BALLAST ROCK. ABOVE STORM SYSTEM SYNTHETIC TURF 1 1 /2" = 1 '-O" P-HA1-03 ABOVE SUBGRADE FENCE POST PI 12" CONC. CURI BARS CONTINI ALTERNATING EXP) (FULL DEPTH( CONTROL JC ADJACENT F ASED EDGE, -ABRIC MAT TO PLASTIC RF MFR.'S ON, UTILIZING FAPLES. ABLE TOP ROCK NITH TOP OF SYNTHETIC TURF SECTION 3TIC 2X4 NAILER, �CRETE WITH EXPANSION ANCHORSv© 12" O.C. IN ZIG ZAG PATTERN. SET TOP OF NAILER SUCH THAT TURF INFILL WILL BE MIN. 1 /4" ABOVE TOP OF ADJACENT SURFACE AFTER COMPACTION. SYNTHETIC TURF EDGE ANCHOR AT BASEBALL/SOFTBALL 1 1 /2" = 1'-0" FINISH GRADE SYNTHETIC TURF CARPET AND INFILL, INFILL TO BE FLUSH WITH ADJACENT SURFACE, SEE SPECS. 25 MM E-LAYER PAD, SEE SPECS 2" MIN. PERMEABLE TOP STONE, SEE SPECS PERMEABLE BASE STONE, DEPTH VARIES WITH SUBGRADE, MIN. 8", SEE SPECS AND SUBGRADE PLAN GEOTEXTILE FABRIC, TENCATE MIRAFI RS380i OR APPROVED EQUAL. OVERLAP MINIMUM 12", SECURELY STAPLE IN PLACE. COMPACT SUBGRADE TO MIN. 95%, SEE CIVIL P-HA1-39 SURVEYED: SCALE: VERTICAL: NAVD 1988 N/A HORIZONTAL: NAD 1983/1991 DESIGNED: DRAWN: ONE INCH DATUM CHECKED: AT FULL SCALE IF NOT ONE INCH N 0. REVISION Y DATE AP P R APPROVED: SCALE ACCORDINGLY ATTACH SIGN TO CHAIN LINK FENCE FABRIC WITH GALVANIZED STEEL HOG RINGS APPROXIMATELY 6" FROM TOP OF RAIL PRE -DRILLED MOUNTING HOLES METAL SIGN, SEE SPECIFICATIONS SEE PLANS FOR LOCATIONS, SIGN DISTANCE TO BE CONFIRMED BY ACTUAL FIELD MEASUREMENTS PRIOR TO FABRICTION OUTFIELD SIGN 1 " = 1'-0" • MY OF R RENTON Planning/Building/Public Works Dept. P-HA1-13 P-HA1-80 R-432662 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CURRENT PLANNING �- amorganroth 08/08/2025 DEVELOPMENT ENGINEERING msippo 08/07/2025 I DATE: HAZEN HIGH SCHOOL MODERNIZATION 07.11.2025 FIELDBOOK: PAGE: LANDSCAPE DETAILS L400 SHEET: OF: 62 OF 7 T U7 O O N 1 u